PRODUCT DESCRIPTION

APC Smart-UPS X 3000VA Rack/Tower LCD with Network Card (SMX3000RMHV2UNC) - Local Warranty

APC SMX3000RMHV2UNC 3000 VA Line-Interactive UPS for Singapore Server Rooms and Comms Cabinets

The APC Smart-UPS X SMX3000RMHV2UNC delivers 3000 VA / 2700 W of protected, conditioned power in a 2U rack/tower convertible chassis. It is a line-interactive design with a true sine wave output, which is what you want in front of servers, storage, switches and anything else running an active-PFC power supply. Singapore's 230 V / 50 Hz mains is stable by regional standards but not immune: lightning season brings switching transients and short sags, and a comms cabinet on a shared riser sees voltage move whenever heavy plant starts elsewhere in the building. The SMX3000RMHV2UNC rides through those events without touching the battery, and covers a genuine outage from its internal pack.

SMX3000RMHV2UNC Outlets, Surge Protection and Voltage Regulation

Connection is via 8× C13 and 1× C19, plus 2 IEC jumper cords, and every powered outlet is battery-backed — there is no surge-only bank to catch you out when you cable the rack. Surge energy rating is 645 Joules, with full-time multi-pole noise filtering on the mains path. The unit accepts 140–280 V at the input, which is a wide enough window to absorb the dips a Singapore building distribution board will hand it.

SMX3000RMHV2UNC with Pre-Installed Network Management Card

This is the NC build. A APC Web/SNMP UPS Network Management Card with environmental monitoring is fitted at the factory, so the UPS is reachable on your network the moment it is racked — Web interface, SNMP, remote shutdown, scheduled self-tests, and email or trap alerting when the mains fails or the battery needs attention. A temperature probe is supplied in the box for environmental monitoring at the rack. For a fleet spread across several sites, or for a comms room nobody visits weekly, having the card pre-installed removes both the purchase and the fitting job. The trade-off is that the single SmartSlot is now occupied, so plan any other SmartSlot accessory accordingly.

Rack Fit, Serviceability and Local Supply from SourceIT

The SMX3000RMHV2UNC is 2U high and 66.7 cm deep, converting to a floor-standing tower with the supplied feet where no rack is available. At 2U it is economical on rack space, though at 66.7 cm it needs a full-depth cabinet — check your rear clearance before you order. The battery is a single user-replaceable APCRBC117 cartridge, so a battery refresh in three to five years is a parts order and a short maintenance window, not a service call-out. Singapore's heat and humidity are hard on VRLA batteries, so plan that refresh into the asset's life from day one. SourceIT supplies the SMX3000RMHV2UNC with local Singapore warranty support and a GST invoice, and we will size the unit against your real load list before you commit.

APC SMX3000RMHV2UNC Datasheet — Technical Specifications

Full published specifications for the APC Smart-UPS X 3000VA Rack/Tower LCD with Network Card (SMX3000RMHV2UNC). Every figure below is taken from Schneider Electric's own product documentation for this exact part number. Where Schneider's documents disagree with each other, or where a value is published for a sibling model but not for this one, we leave the row out rather than guess.

General

Part Number (SKU) SMX3000RMHV2UNC
Product Family APC Smart-UPS X
Topology Line interactive
Form Factor 2U rack/tower convertible
Output Power Capacity 3000 VA / 2700 W
Maximum Configurable Power 3000 VA / 2700 W
Pre-installed Device APC Web/SNMP UPS Network Management Card with environmental monitoring
Display Multi-function LCD status and control console
Manufacturer Warranty 3 years repair or replace (excluding battery); 2 years for the battery — APC by Schneider Electric
Local Warranty (Singapore) Yes — supplied by SourceIT with a GST invoice

Output

Nominal Output Voltage 230 V (configurable 208 V, 220 V, 240 V)
Output Harmonic Distortion Less than 5%
Output Frequency 50/60 Hz ± 3 Hz, synchronised to mains
Waveform Type Sine wave
Transfer Time 10 ms maximum
Output Connections (8) IEC 320 C13 — battery backup
(1) IEC 320 C19 — battery backup
(2) IEC jumper cords
Surge Energy Rating 645 Joules

Input

Nominal Input Voltage 208 V, 220 V, 230 V, 240 V
Input Voltage Range 140–280 V
Input Frequency 50/60 Hz ± 3 Hz (auto-sensing)
Input Connection Type IEC 320 C20 inlet
Cord Options Schuko CEE 7/EU1-16P, BS1363A British

Batteries & Runtime

Battery Type Sealed lead-acid (VRLA)
Battery Capacity 738 VAh
Replacement Battery Cartridge APCRBC117
Expected Battery Life 3–5 years
Typical Recharge Time 3 hours
External Battery Packs Up to 10 × SMX120RMBP2U (2,214–15,498 VAh)

Schneider Electric does not publish runtime-at-load figures for this reference, so we do not quote any. Runtime depends entirely on the connected load, battery age and ambient temperature. Tell us your actual load in watts and we will size it against the official runtime curves.

Communications & Management

Pre-installed Card APC Web/SNMP UPS Network Management Card with environmental monitoring
Available SmartSlot Quantity 0 — the single SmartSlot is occupied by the pre-installed card
Interface Ports RS-232 serial (signalling cable supplied)
Environmental Monitoring Temperature probe supplied in the box

Physical & Environmental

Rack Height 2U
Chassis Depth 66.7 cm
Rack Hardware Included Rack mounting support rails
Dimensions (H × W × D, rack orientation) 8.5 × 43.2 × 66.7 cm
Net Weight 37.32 kg
Shipping Weight 45.36 kg
Operating Temperature 0–40 °C
Storage Temperature -15–45 °C
Operating Relative Humidity 0–95%, non-condensing
Operating Elevation 0–3,048 m (0–10,000 ft)
Audible Noise at 1 m 55 dBA
Thermal Dissipation 184 BTU/hr
Certifications CE, C-Tick, EAC, GOST, IRAM, VDE (EN/IEC 62040-1:2019/A11:2021, EN/IEC 62040-2)
Colour Black

Notes on omitted figures

Schneider's data sheet for this reference prints two different typical transfer times (2–4 ms and 6 ms) in the same document, so we publish only the stated 10 ms maximum.

Official Schneider Electric product name: APC Smart-UPS X, Line Interactive, 3kVA, Rack/tower convertible 2U, 208V-230V, 8x C13 + 1x C19 IEC, Network card, Extended runtime

Compatibility & Runtime

What you can plug into it

The SMX3000RMHV2UNC provides 8× C13 and 1× C19, plus 2 IEC jumper cords. Every powered outlet on this unit is battery-backed — there are no surge-only sockets, so anything you connect gets both conditioning and ride-through. The IEC jumper cords are short C13-to-C14 leads for cabling neighbouring rack equipment tidily; they are not additional outlets. Servers, storage shelves and switches with C14 inlets connect directly with a C13-to-C14 cord, and the C19 outlet takes higher-current C20-inlet loads such as blade chassis or large storage arrays.

Rack fit and depth

This is a 2U rack/tower convertible unit, 66.7 cm deep. Note that although this is only 2U, it is 66.7 cm deep — considerably deeper than the 4U short-depth Smart-UPS X models. Check your cabinet's internal depth and the clearance behind your rear rails before ordering; this unit is not suitable for a shallow comms cabinet. Rack hardware included in the box: rack mounting support rails. The unit converts to a floor-standing tower using the supplied feet where a rack is not available.

Input supply and Singapore mains

Input is via IEC 320 C20 inlet, and the unit accepts 140–280 V at 50/60 Hz auto-sensing — comfortably wide for Singapore's nominal 230 V / 50 Hz supply and for the sags that come with afternoon storm switching on the PUB network. At this rating the unit should be fed from its own suitably rated circuit; do not share a 13 A general-purpose socket with other equipment. Confirm the supplied cord type when you order — Schneider ships this reference with several regional cord options and we will supply the correct one for Singapore.

Batteries and runtime

The internal battery is a maintenance-free sealed lead-acid (VRLA) pack, replaced as a single cartridge: APCRBC117, which we stock — see APC Replacement Battery Cartridge #117. Typical recharge time is three hours. In Singapore's year-round heat and humidity, ambient temperature is the single biggest factor in how long a VRLA pack lasts, so keep the unit in the conditioned part of the room and plan a cartridge replacement roughly every three to five years.

Runtime extends with SMX120RMBP2U external battery packs, up to 10 on this model — see APC Smart-UPS X Battery Pack, Extended Runtime, 120V 2U.

Schneider Electric does not publish runtime-at-load figures for this reference, so we do not quote any. Runtime depends entirely on the connected load, battery age and ambient temperature. Tell us your actual load in watts and we will size it against the official runtime curves.

Network management and monitoring

This is the NC build: a APC Web/SNMP UPS Network Management Card with environmental monitoring is factory-fitted, so the unit is on the network out of the box for Web and SNMP monitoring, remote shutdown and alerting, without buying a card separately. The trade-off is that the single SmartSlot is now occupied — you cannot add a second SmartSlot accessory unless you remove the card. Schneider's documentation for this reference names the card by description rather than by part number, and the card generation has changed over the life of the SKU, so we do not print a part number here. Ask us and we will confirm the card revision in current stock. If you need a non-networked unit at a lower price, the equivalent SmartSlot build is listed separately in the ordering table below.

Locally attached shutdown uses the supplied USB or RS-232 signalling cable. Check the current PowerChute compatibility matrix for your operating system or hypervisor before you rely on scripted shutdown — Schneider's documentation for this reference lists the bundled media without naming a software version, so we do not claim one. This is a Smart-UPS X unit and does not include APC SmartConnect cloud monitoring; SmartConnect is a feature of the newer Smart-UPS "C" references.

Package Contents & Smart-UPS X Ordering Information

In the box

  • CD with software
  • Rack mounting support rails
  • Smart-UPS signalling RS-232 cable
  • Temperature probe
  • User manual
  • Web/SNMP management card (pre-installed)
  • APC Smart-UPS X 3000VA Rack/Tower LCD with Network Card (SMX3000RMHV2UNC)

APC Smart-UPS X range at SourceIT

Model Capacity · form factor · outlets
SMX750I 750 VA / 600 W · 2U rack/tower · 8× C13
SMX1000I 1000 VA / 800 W · 2U rack/tower · 8× C13
SMX1500RMI2U 1500 VA / 1200 W · 2U rack/tower · 8× C13
SMX1500RMI2UNC 1500 VA / 1200 W · 2U rack/tower · 8× C13
SMX2200HV 2200 VA / 1980 W · 4U short depth · 8× C13 + 2× C19
SMX2200HVNC 2200 VA / 1980 W · 4U short depth · 8× C13 + 2× C19
SMX2200RMHV2U 2200 VA / 1980 W · 2U rack/tower · 8× C13 + 1× C19
SMX2200R2HVNC 2200 VA / 1980 W · 2U rack/tower · 8× C13 + 1× C19
SMX3000HV 3000 VA / 2700 W · 4U short depth · 8× C13 + 2× C19
SMX3000HVNC 3000 VA / 2700 W · 4U short depth · 8× C13 + 2× C19
SMX3000RMHV2U 3000 VA / 2700 W · 2U rack/tower · 8× C13 + 1× C19
SMX3000RMHV2UNC (this listing) 3000 VA / 2700 W · 2U rack/tower · 8× C13 + 1× C19

Models ending NC ship with an APC network management card already fitted; the others leave the SmartSlot free. The 4U references are the short-depth chassis (48.3 cm); the 2U references are 66.7 cm deep. Outlet counts differ between the two chassis — the 4U builds carry two C19 outlets, the 2U builds carry one.

Replacement battery cartridge

APCRBC117 APC Replacement Battery Cartridge #117 — the correct cartridge for the SMX3000RMHV2UNC

Cartridge part numbers are not interchangeable across the Smart-UPS X range: the 4U 2200/3000 VA builds take APCRBC143, the 2U 2200/3000 VA builds take APCRBC117, the 1500 VA builds take APCRBC115 and the 750/1000 VA builds take APCRBC116. Order against the SKU, not the VA rating.

External battery packs

SMX120RMBP2U APC Smart-UPS X Battery Pack, Extended Runtime, 120V 2U — up to 10 on the SMX3000RMHV2UNC
SMX48RMBP2U APC Smart-UPS X External Battery Pack 48V, 2U rack/tower
SMX120BP APC Smart-UPS X 120V External Battery Pack, Tower/Rack

Network management and monitoring accessories

AP9640 APC UPS Network Management Card 3
AP9641 APC UPS Network Management Card 3 with Environmental Monitoring
AP9335TH APC Temperature & Humidity Sensor

The SMX3000RMHV2UNC already has its SmartSlot occupied by the factory-fitted card, so a second card cannot be added. The sensor above connects to the environmental port on the installed card where that card supports it — ask us to confirm against the card revision in current stock.

Rack rails, brackets and tower feet for this model are supplied in the box as listed above and do not need to be ordered separately.

Datasheet & Downloads

Official Schneider Electric documentation for the APC SMX3000RMHV2UNC. Every link below was checked and resolved at the time this page was published.

Schneider's own download-pdf links on se.com are blocked to automated checking, so we do not publish them; the data sheet PDFs above are the same Schneider documents carried on distributor document servers, and we verified the part number printed inside each one. If you need the document straight from Schneider, open the product page linked above and use its Documents tab. Ask us if you need a stamped copy of any certificate for a tender submission.

Frequently Asked Questions — APC SMX3000RMHV2UNC

What is the difference between the 3000 VA and 2700 W ratings, and how do I size the SMX3000RMHV2UNC for my load?

VA is the apparent power the UPS can deliver and W is the real power. Modern IT equipment is close to unity power factor, so in practice the 2700 W figure is the one that limits you. Add up the nameplate or measured draw of everything you intend to connect, then leave headroom — we usually recommend loading a UPS to no more than 70–80% of its watt rating so it has capacity for growth and so the battery is not working at its worst-case discharge rate. For the SMX3000RMHV2UNC that means planning for roughly 2025 W of steady load. Send us your equipment list and we will size it properly.

How long will the SMX3000RMHV2UNC run on battery?

Schneider Electric does not publish runtime-at-load tables for this reference, and we will not invent figures for it. Runtime depends on how heavily the unit is loaded, how old the battery is and how warm the room is — a UPS at 30% load runs many times longer than the same unit at 90%. You can extend runtime substantially with SMX120RMBP2U external battery packs, up to 10 on this model. Tell us your actual load in watts and the ride-through you need, and we will size it against Schneider's official runtime curves before you commit.

What does the "NC" in SMX3000RMHV2UNC mean?

NC denotes the network card build. Schneider ships this reference with a APC Web/SNMP UPS Network Management Card with environmental monitoring already installed, so the UPS is manageable over the LAN by Web browser and SNMP from the moment it is racked, and it comes with a temperature probe for environmental monitoring. The non-NC version of the same hardware leaves the SmartSlot empty and costs less, but you then buy and fit a card yourself. One consequence worth knowing before you order: the NC build has no free SmartSlot left, so a second SmartSlot accessory cannot be added alongside the card.

Does the SMX3000RMHV2UNC produce a true sine wave, and will it work with an active-PFC power supply?

Yes — Schneider's data sheet for this exact model states sine wave output, not a step-approximated or simulated waveform. That matters: active power-factor-corrected server and workstation PSUs, which is nearly everything sold in the last decade, can misbehave or shut down on a stepped waveform when the UPS transfers to battery. A genuine sine wave output like this one is the safe choice for servers, NAS units, network gear and anything with an active-PFC supply. Note this is a line-interactive UPS, not a double-conversion online unit — it transfers to inverter on a mains failure rather than running the load through the inverter continuously. For loads that cannot tolerate any transfer at all, look at the APC Smart-UPS On-Line SRT range we also carry.

Which replacement battery can I fit to the SMX3000RMHV2UNC, and can I change it myself?

The correct cartridge is APCRBC117 — see APC Replacement Battery Cartridge #117. It is a user-replaceable cartridge, so you do not need a service visit to change it. Schneider's documentation for this reference does not state that the cartridge can be exchanged with the load still running, so plan a short maintenance window rather than assuming otherwise. Do not substitute a cartridge from a neighbouring model: within the Smart-UPS X range the cartridge differs by chassis, not by VA rating, and fitting the wrong one is a common and expensive ordering mistake.

How much rack space does the SMX3000RMHV2UNC need, and are rails included?

It occupies 2U and is 66.7 cm deep. Rack hardware supplied in the box: rack mounting support rails. Despite being only 2U, this build is 66.7 cm deep — measure your cabinet before ordering, since the 4U short-depth Smart-UPS X models are 18 cm shallower. It also converts to a tower using the supplied feet. Remember to budget for the weight as well as the U height: this unit is 37.32 kg, so mount it at the bottom of the rack.

How does the SMX3000RMHV2UNC compare with the SMX3000HVNC in your catalogue?

The SMX3000HVNC (APC Smart-UPS X 3000VA Short Depth LCD with Network Card) is the same 3000 VA capacity in a different chassis: 4U at 48.3 cm deep with 8× C13 and 2× C19, plus 2 IEC jumper cords, against this unit's 2U at 66.7 cm with 8× C13 and 1× C19, plus 2 IEC jumper cords. Choose on the shape of your cabinet and your outlet mix, not on the electrical rating — they are electrically equivalent. Note they take different replacement battery cartridges (APCRBC143 against APCRBC117).

Is the SMX3000RMHV2UNC covered by a Singapore warranty?

Yes. Every APC SMX3000RMHV2UNC sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SMX3000RMHV2UNC with a manufacturer warranty of three years repair or replace on the unit (excluding the battery) and two years on the battery. Schneider Electric publishes this term globally for the Smart-UPS range with no separate European or rest-of-world figure. Register the unit with Schneider after purchase, and keep your invoice — the warranty period runs from the original date of purchase.


We Also Recommend

APC Easy UPS On-Line SRV 1000VA RM 230V with Battery Pack, Rail Kit (SRV1KRILRK-E) - SourceIT

APC Easy UPS SRV 1000VA RM 230V with Battery Pack

Regular price S$19,453.40
APC Smart-UPS RT 20kVA 230V International (SRTG20KXLI) - SourceIT

APC Smart-UPS RT 20kVA 230V International

Sale price S$15,180.00
Save S$7,911.08
APC Smart-UPS RT 15kVA 230V International (SRTG15KXLI) - SourceIT

APC Smart-UPS RT 15kVA 230V International

Sale price S$13,022.60
Save S$1,656
APC Smart-UPS SRT 10000VA RM 230V (SRT10KRMXLI) - SourceIT

APC Smart-UPS SRT 10000VA RM 230V

Sale price S$8,910.20
Save S$1,784.80
APC Smart-UPS SRT 8000VA RM 230V (SRT8KRMXLI) - SourceIT

APC Smart-UPS SRT 8000VA RM 230V

Sale price S$7,539.40
Save S$3,921.96