APC UPS Network Management Card 3

SKU: AP9640

  • S$510.60
    Unit price per 
  • Save S$101.20
Shipping calculated at checkout.

PRODUCT DESCRIPTION

APC UPS Network Management Card 3, Gigabit Ethernet, Secure Remote UPS Monitoring (AP9640) - 2 Years Local Warranty

Secure Remote UPS Monitoring and Management Over Your Network

The APC UPS Network Management Card 3 (AP9640) installs in a Smart-UPS SmartSlot bay and gives the UPS its own IP address, web interface, command line and SNMP agent. From there you can see load, battery status, runtime and input conditions, receive real-time event notification, and pull detailed data and event logs - without walking to the rack.

NMC3 is the current generation of APC's management card and it is a security-led design: HTTPS with TLS, SSH, SNMPv3, RADIUS authentication and 802.1X port-based network access control are all supported, alongside the older HTTP, Telnet and SNMPv1 methods where a legacy monitoring system still needs them.

Protocol Coverage for NMS, BMS and Building Automation

The card speaks the protocols a mixed Singapore estate actually runs on. For network monitoring: SNMP v1, v2c and v3, Syslog and SMTP e-mail alerting. For building and industrial systems: Modbus TCP/IP and BACnet/IP, so a UPS in a comms room can report into the same head-end as the chillers and the access control. For file transfer and firmware work: FTP and SCP. Addressing covers DHCP, BOOTP and NTP time sync.

The card is also the network half of PowerChute Network Shutdown, which lets a UPS gracefully shut down physical and virtual servers when runtime runs short - the piece most SME server rooms miss until the first long outage.

Gigabit Ethernet and a One-Year Secure NMC System Subscription

Connection is a single 10/100/1000 Base-T RJ45 port, with a micro-USB console port for local configuration. Every AP9640 includes a one-year Secure NMC System subscription, Schneider's programme for keeping card firmware current against new vulnerabilities - a point worth raising with any customer who has to answer a security audit.

The card is EcoStruxure IT compatible, so it can report into Schneider's monitoring platform alongside the rest of the estate.

Built for Server Rooms and Comms Cabinets on Singapore's 230V Mains

A UPS that nobody can see is a UPS nobody maintains. Fitting an AP9640 turns a standalone Smart-UPS into a monitored asset: you get e-mail alerts and SNMP traps on UPS and power events, and detailed data and event logs that tell you how often the PUB supply actually dipped during the last storm season.

The card runs at 0 to 45 °C and 0 to 95% humidity. Supplied and invoiced locally in Singapore with GST.

APC AP9640 Datasheet — Technical Specifications

General

Part Number (SKU) AP9640
Schneider Electric Product Name Network Management Card 3 (NMC3), secure remote UPS monitoring and management
Form Factor APC SmartSlot plug-in card
Included Subscription 1-Year Secure NMC System subscription
Environmental Sensor Ports None - see AP9641 for a card with universal I/O ports
Compliance Green Premium, EU RoHS compliant
Warranty 2-Year Manufacturer Warranty (APC by Schneider Electric)
Local Warranty (Singapore) Yes - supplied and supported locally by SourceIT

Function & Connectivity

Network Port 1 x 10/100/1000 Base-T Ethernet (RJ45)
Console Port 1 x micro-USB
Web & Terminal Access HTTP, HTTPS (TLS), SSH, Telnet
Network Monitoring SNMP v1, SNMP v2c, SNMP v3, Syslog, SMTP e-mail alerts
Building & Industrial Modbus TCP/IP, BACnet/IP
File Transfer FTP, SCP
Authentication & Access RADIUS, 802.1X (EAPoL)
Addressing & Time DHCP, BOOTP, NTP
Shutdown Software PowerChute Network Shutdown supported
Management Platform EcoStruxure IT compatible
Firmware (Smart-UPS) NMC3 firmware v2.5.5.1, released 13 June 2025

Physical & Environmental

Dimensions (H x W x D) 38 x 121 x 114 mm
Net Weight 0.08 kg
Package Weight 0.34 kg
Package Dimensions 23.5 x 15.9 x 5.1 cm
Operating Temperature 0 to 45 °C
Operating Humidity 0 to 95% non-condensing
Operating Altitude 0 to 10,000 ft
Storage Temperature -5 to 45 °C
Storage Altitude 0 to 15,240 m
Certifications EN 55022 Class A, EN 55024, ICES-003, AS/NZS 3548 (C-Tick) Class A, FCC Part 15 Class A, GOST, VCCI Class A
Compatibility & Fit

Which UPS families accept the AP9640. The card fits an APC SmartSlot bay. Schneider's UPS network management card compatibility chart lists single-phase support for SUA, SUM, SURT, SURTA, SURTD and SUVT legacy units, MGE Galaxy 3500, and the current SMT, SMX, SRT, SRC, SMTL, SRTL and SRYL ranges, plus Symmetra LX and Symmetra RM at firmware v1.5.1.1 or later. Three-phase support covers Symmetra PX1 20/40/48 kW, Symmetra PX2 96/100/160 kW, Galaxy VM, Galaxy VX, Galaxy PX, Galaxy 3L Pro, Easy UPS 3-Phase Modular and Easy UPS 3M Advanced. Legacy SUA units must be manufactured after 2008 and running firmware v1.4.2 or later.

In the SourceIT catalogue that covers the Smart-UPS SmartConnect range (SMT and SMC), the Smart-UPS X range - for example the SMX1500RMI2U - and the Smart-UPS On-Line SRT range, such as the SRT3000RMXLI. Note that the "NC" variants of the Smart-UPS X ship with a management card already fitted and no free SmartSlot - check before ordering a second card.

How many SmartSlots do I have? Most single-phase Smart-UPS models have exactly one. That slot can hold this card, the AP9641, or the AP9613 dry contact card - not two of them. Choose on function: AP9640 for network management alone, AP9641 if you also want temperature and humidity sensing from the same slot.

Sensors. The AP9640 has no universal I/O ports, so it does not take the AP9335T or AP9335TH sensors. If environmental monitoring is part of the requirement, specify the AP9641 instead, or add a NetBotz Rack Monitor 250 (NBRK0250A) for rack-level sensing and door access control.

Not for Rack PDUs. APC Rack PDUs with network management - the AP79xx, AP88xx and APDU ranges - have their own network port built in and do not use a Network Management Card. The AP9640 is for UPS SmartSlot bays only.

What you can do once it is on the network. Browser and command-line management, SNMP polling and traps into your NMS, e-mail alerts, Syslog, scheduled self-tests, event and data logs, firmware updates over the network, Modbus TCP/IP or BACnet/IP into a BMS, and graceful server shutdown through PowerChute Network Shutdown.

Package Contents & APC Network Management Card 3 Ordering Information

In the box: Network Management Card 3, user manual, USB cable.

APC Network Management Card 3 range and related management options

Model What it adds
AP9640 (this listing) Network management - Gigabit Ethernet, no sensor ports
AP9641 Network management plus 2 universal I/O ports, 3 USB ports, Modbus RTU over serial; ships with an AP9335T temperature sensor
AP9613 Dry contact signalling only - 4 input contacts, 6 output relays; no network

Sensors and rack monitoring

AP9335TH Temperature and humidity sensor, RJ45, 3.9 m lead - requires a host with universal I/O ports (the AP9641 or the AP9613) or a NetBotz appliance; it will not connect to the AP9640
NBRK0250A NetBotz Rack Monitor 250 - 1U appliance, 6 universal sensor ports, badged access control for two rack doors

Smart-UPS models in the SourceIT catalogue that take this card - confirm the SmartSlot is free before ordering

SMT1500RMI2UC Smart-UPS 1500VA LCD RM 2U 230V with SmartConnect
SMT2200RMI2UC Smart-UPS 2200VA LCD RM 2U 230V with SmartConnect
SMX1500RMI2U Smart-UPS X 1500VA Rack/Tower LCD 230V
SRT3000RMXLI Smart-UPS On-Line 3kVA Rackmount 2U 230V
Datasheet & Downloads

Official Schneider Electric documentation for the APC AP9640. Links open in a new tab.

Need a specific document, a compliance declaration or a written quotation? Contact SourceIT and we will supply it.

Frequently Asked Questions — APC AP9640

What is the difference between the AP9640 and the AP9641?

Sensor ports. The AP9640 has none. The AP9641 adds two universal I/O ports that accept the AP9335T temperature sensor or the AP9335TH temperature and humidity sensor, plus three USB ports rather than one micro-USB console, Modbus RTU over serial, and support for the AP9834 Wi-Fi dongle. The AP9641 also ships with an AP9335T temperature sensor in the box. Network management itself is the same on both cards. If you have one SmartSlot and any interest in rack temperature, the AP9641 is usually the better buy.

Will it fit my UPS?

It needs a free SmartSlot. Schneider's compatibility chart covers SMT, SMX, SRT, SRC, SMTL, SRTL and SRYL current ranges plus SUA, SUM, SURT, SURTA, SURTD, SUVT and MGE Galaxy 3500 legacy units, Symmetra LX and RM, and the three-phase Symmetra PX and Galaxy families. Legacy SUA units need post-2008 manufacture and firmware v1.4.2 or later. Send us your UPS part number and we will confirm both compatibility and whether the slot is already occupied.

Can I use it with an APC Rack PDU?

No, and you do not need to. APC's managed Rack PDUs - the AP79xx, AP88xx and APDU Advanced ranges - have network management built into the unit with their own Ethernet port, web interface and SNMP agent. Network Management Cards are for UPS SmartSlot bays.

Which protocols does it support?

HTTP and HTTPS with TLS, SSH, Telnet, SNMP v1, v2c and v3, FTP, SCP, Modbus TCP/IP, BACnet/IP, RADIUS, 802.1X (EAPoL), DHCP, BOOTP, NTP, Syslog and SMTP. That covers modern secure management, legacy monitoring systems and building automation head-ends.

What is the Secure NMC System subscription that comes with it?

Every AP9640 includes a one-year Secure NMC System subscription, Schneider's programme for keeping the card's firmware current against newly disclosed vulnerabilities. It is a useful line to have on file if your organisation has to evidence patching of network-connected infrastructure.

Does it let servers shut down automatically?

Yes, in combination with PowerChute Network Shutdown, which the card supports. PowerChute talks to the card over the network and shuts physical and virtual machines down gracefully before the battery runs out. Ask SourceIT about licensing for your host count.

Does it come with a Singapore warranty?

Yes. Every APC AP9640 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the AP9640 with a 2-year manufacturer warranty.


We Also Recommend

APC Easy UPS On-Line SRV 1000VA RM 230V with Battery Pack, Rail Kit (SRV1KRILRK-E) - SourceIT

APC Easy UPS SRV 1000VA RM 230V with Battery Pack

Regular price S$19,453.40
APC Smart-UPS RT 20kVA 230V International (SRTG20KXLI) - SourceIT

APC Smart-UPS RT 20kVA 230V International

Sale price S$15,180.00
Save S$7,911.08
APC Smart-UPS RT 15kVA 230V International (SRTG15KXLI) - SourceIT

APC Smart-UPS RT 15kVA 230V International

Sale price S$13,022.60
Save S$1,656
APC Smart-UPS SRT 10000VA RM 230V (SRT10KRMXLI) - SourceIT

APC Smart-UPS SRT 10000VA RM 230V

Sale price S$8,910.20
Save S$1,784.80
APC Smart-UPS SRT 8000VA RM 230V (SRT8KRMXLI) - SourceIT

APC Smart-UPS SRT 8000VA RM 230V

Sale price S$7,539.40
Save S$3,921.96