APC Smart-UPS C 2000VA LCD 230V
PRODUCT DESCRIPTION
APC Smart-UPS C, Line Interactive, 2000VA / 1300W, Tower, 230V (SMC2000I) - 2 Years Local Warranty
2000 VA / 1300 W of Sine Wave Protection for Singapore Offices and Comms Cabinets
The APC Smart-UPS C SMC2000I delivers 2000 VA and 1300 W of true sine wave output from a line-interactive topology with Automatic Voltage Regulation. Sine wave output matters more than the datasheet line suggests: active-PFC power supplies in modern servers, workstations and NAS units can drop out or run hot on a step-approximated waveform, and the SMC series avoids that problem entirely with less than 5% output distortion at full load.
AVR Rides Out PUB Voltage Dips Without Draining the Battery
Singapore runs on 230 V, 50 Hz mains, and the day-to-day threat to equipment here is rarely a full blackout — it is the sag when a PUB feeder is switched, the brownout during a storm, and the surge that follows. Automatic Voltage Regulation corrects those without touching the battery, which is why an AVR unit's batteries last longer in service than a cheaper standby UPS's do in the same building. The SMC2000I accepts input from 180 to 287 V, adjustable down to 170 V and up to 300 V, and corrects within that window using the transformer rather than the battery.
Six C13 Outlets Plus a C19 for a Heavier Load
The SMC2000I gives you six IEC C13 outlets and one IEC C19 outlet, all of them battery-backed — there are no surge-only sockets on this model. The C19 is the useful one: it takes a higher-current C20-terminated cord, so a blade chassis, a larger switch or a second PDU can be fed from the UPS directly. The unit itself is fed by an IEC C20 inlet, so plan for a matching cord and, at this rating, a dedicated circuit is the sensible choice.
Tower Format, Graphic LCD, Genuine APC Battery
This is a 0U tower — 216 mm high, 170 mm wide, 440 mm deep and 27.5 kg — designed to sit beside or under a desk, or on the floor of a comms cupboard. It is not rack-mountable; for a rack, choose the SMC2000I-2U instead. The multifunction graphic LCD reports load, runtime and input voltage at a glance, and the battery is a genuine APC APCRBC148 cartridge that you can order from us when it reaches end of life.
APC SMC2000I Datasheet — Technical Specifications
General
| Part Number (SKU) | SMC2000I |
| Product Name | APC Smart-UPS C, Line Interactive, 2000VA, Tower, 230V, 6x IEC C13 + 1x IEC C19 outlets, USB and Serial communication, AVR, Graphic LCD |
| Topology | Line interactive |
| Form Factor | Tower (not rack-mountable) |
| Display | Multifunction graphic LCD status and control console |
| Certifications | CE, C-Tick, EAC, GOST, SABS, VDE (later revisions add UK PSTI) |
| Manufacturer Warranty | 2-Year Manufacturer Warranty (APC by Schneider Electric) |
| Local Warranty | Local Warranty (Singapore) |
Output
| Output Power Capacity | 2000 VA / 1300 W |
| Nominal Output Voltage | 230 V (configurable for 220 V or 240 V) |
| Output Frequency | 50 Hz, synchronised to mains |
| Waveform | Sine wave |
| Output Voltage Distortion | Less than 5% at full load |
| Output Connections | (6) IEC 320 C13 — battery backup; (1) IEC 320 C19 — battery backup |
| Surge Energy Rating | 300 Joules |
| Noise Filtering | Full-time multi-pole noise filtering, 0.3% IEEE surge let-through |
Input
| Nominal Input Voltage | 230 V |
| Input Voltage Range (mains operation) | 180 to 287 V |
| Adjustable Input Voltage Range | 170 to 300 V |
| Input Frequency | 47 to 63 Hz |
| Input Connection | IEC 320 C20 |
| Voltage Regulation | Automatic Voltage Regulation (AVR) |
Batteries & Runtime
| Battery Type | Maintenance-free sealed lead-acid with suspended electrolyte, leakproof |
| Replacement Battery Cartridge | APCRBC148 |
| Typical Recharge Time | 3 hours |
| Expected Battery Life | 3 to 5 years |
| Charger Power | 166 W |
| Runtime at Load | Schneider Electric publishes no runtime table for this model — contact SourceIT with your load in watts for a sizing estimate |
Communications & Management
| Communication Ports | USB and serial |
| SmartSlot | None — an internal network management card cannot be fitted |
| Management Software | Compatible with APC PowerChute management software for graceful shutdown over USB or serial |
Physical & Environmental
| Dimensions (H × W × D) | 216 × 170 × 440 mm |
| Net Weight | 27.5 kg |
| Shipping Weight | 30.0 kg |
| Operating Temperature | 0 to 40 °C (storage −15 to 45 °C) |
| Relative Humidity | 0 to 95%, non-condensing |
| Operating Altitude | 0 to 3,000 m |
| Audible Noise | 45 dBA at 1 m |
| Heat Dissipation | 135 BTU/hr |
| Package Contents | Software CD, documentation CD, USB cable |
Specifications We Have Not Published
Schneider Electric does not publish a transfer time, a battery VAh figure, an input current or a battery bus voltage on the SMC2000I data sheet, so none is stated here. UL and cUL are not on the certification list for this 230 V IEC model and are not claimed. The Smart-UPS C series takes no external battery pack, so no extended-runtime option exists for this model. Where Schneider Electric does not publish a figure for this exact model, SourceIT leaves it out rather than estimate it from a similar part number.
Compatibility & Runtime
Everything on this UPS is battery-backed — six IEC C13 outlets and one IEC C19 — so you do not have to work out which sockets are surge-only. The C19 accepts a C20-terminated cord for a heavier single load.
Sizing. The 1300 W figure is the real constraint, not the 2000 VA. Add up the nameplate watts of everything you intend to plug in and keep the total below about 80% of 1300 W — roughly 1040 W — to leave headroom for inrush and for battery ageing. Schneider publishes no runtime table for this model, so we will not quote minutes; tell us your actual load and target runtime and we will size it.
Input. The unit takes an IEC C20 inlet. At 2000 VA a dedicated circuit is the sensible choice rather than sharing a general office ring.
Form factor. Tower only, 216 × 170 × 440 mm. It is not rack-mountable and there is no rail kit for it — the rack build is the separate SMC2000I-2U.
Management. This model has no SmartSlot. An internal APC network management card such as the AP9640 or AP9641 cannot be fitted to any Smart-UPS C unit — management is over the bundled USB or serial port to a host running APC PowerChute software. If you need SNMP or web management in the rack, choose a Smart-UPS SMT or SMX model with a SmartSlot, or a Smart-UPS C SmartConnect model with a built-in Ethernet port.
Package Contents & Smart-UPS C Series Ordering Information
In the Box
- APC Smart-UPS C 2000VA UPS (SMC2000I)
- Software CD
- Documentation CD
- USB cable
Smart-UPS C Series Ordering Information
The Smart-UPS C range runs from 1000 VA to 3000 VA in both tower and 2U rack builds. Watts, not VA, is the number to size against:
| APC Smart-UPS C 1000VA LCD 230V | SMC1000I |
| APC Smart-UPS C 1500VA LCD 230V | SMC1500I |
| APC Smart-UPS C 2000VA LCD 230V (this listing) | SMC2000I |
| APC Smart-UPS C 3000VA LCD 230V | SMC3000I |
Smart-UPS C rackmount siblings
| APC Smart-UPS C 1000VA 2U Rack LCD 230V | SMC1000I-2U |
| APC Smart-UPS C 1500VA 2U Rack LCD 230V | SMC1500I-2U |
| APC Smart-UPS C 2000VA 2U Rack 230V | SMC2000I-2U |
| APC Smart-UPS C 3kVA Rackmount 2U 230V | SMC3000RMI2U |
Smart-UPS C SmartConnect builds (with built-in Ethernet monitoring)
Replacement battery cartridge for this model
| APC Replacement Battery Cartridge #148 | APCRBC148 |
Datasheet & Downloads
Full technical documentation for the APC SMC2000I is published by Schneider Electric. The official product page below lists the Schneider Electric product data sheet and User Guide 990-4493G.
Schneider Electric serves its datasheet and manual PDFs through a redirecting download service that we cannot link to reliably, so we do not publish a direct PDF link that might break or return the wrong model's document. Email sales@sourceit.com.sg with the model number and we will send you the current APC SMC2000I product data sheet and user manual as PDFs, along with a quotation.
Frequently Asked Questions — APC SMC2000I
What is the difference between 2000 VA and 1300 W, and which should I size against?
Size against the watts. VA is apparent power and W is real power; the UPS will hit its 1300 W ceiling long before the 2000 VA figure becomes relevant for modern IT loads. Total the nameplate watts of your equipment and aim to stay under roughly 1040 W, leaving 20% headroom for inrush and for the battery losing capacity as it ages.
How long will it run for?
Schneider Electric does not publish a runtime table for the SMC2000I, so we will not invent one. Runtime falls away sharply as load rises — a unit at 30% load runs far more than three times as long as one at 90%. Send us your load in watts and the minutes you need and we will size it against the real curve.
Is the output a true sine wave? Will it work with an active-PFC power supply?
Yes to both. The SMC2000I produces a true sine wave with less than 5% distortion at full load, which is exactly what active-PFC server and workstation supplies need. Step-approximated output — common on Back-UPS and Easy UPS models — can cause those supplies to drop the load or run hot, which is the main reason to step up to a Smart-UPS.
Which replacement battery does it take, and can I change it myself?
The genuine APC cartridge is the APCRBC148, and it is user-replaceable. Expect 3 to 5 years of service life, less in a warm cupboard — Singapore ambient temperatures are hard on sealed lead-acid. Follow the APC user guide procedure and plan the swap into a maintenance window.
Can I fit a network management card for SNMP monitoring?
This model has no SmartSlot. An internal APC network management card such as the AP9640 or AP9641 cannot be fitted to any Smart-UPS C unit — management is over the bundled USB or serial port to a host running APC PowerChute software. If you need SNMP or web management in the rack, choose a Smart-UPS SMT or SMX model with a SmartSlot, or a Smart-UPS C SmartConnect model with a built-in Ethernet port.
Can I rack-mount it, or add an external battery pack?
Neither. The SMC2000I is a tower-only unit with no rail kit, and the Smart-UPS C series takes no external battery pack — runtime is fixed by the internal battery. If you need a rack build, the SMC2000I-2U is the same electronics in a 2U chassis.
How does it compare with the SMC3000I?
The SMC3000I steps up to 3000 VA / 2100 W and adds two more C13 outlets, at 435 × 197 × 544 mm and 43 kg against this unit's 27.5 kg. If your load is close to 1000 W today and likely to grow, the 3000 VA is the safer buy.
Is the warranty valid in Singapore, and do I get a GST invoice?
Yes. Every APC SMC2000I sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SMC2000I with a 2-year manufacturer warranty.