APC NetBotz Rack Mount, Security and Environmental Appliance
PRODUCT DESCRIPTION
APC NetBotz Rack Monitor 250, 1U Security & Environmental Appliance, 6 Sensor Ports (NBRK0250A) - 2 Years Local Warranty
Rack-Level Environmental Monitoring and Door Access Control in 1U
The APC NetBotz Rack Monitor 250 (NBRK0250A) is a 1U appliance that watches a rack the way a network management card watches a UPS. Schneider positions it as essential sensing, access control and alerting for rack-mount applications: environmental alerts for overheating, fluids and leaks, humidity and smoke, with badged access control for two rack doors.
It carries six universal sensor ports on the unit itself and supports up to 42 wired sensors and 47 wireless sensors once sensor pods and the wireless coordinator are added - so one appliance can cover a row of cabinets rather than a single rack.
The Failure Modes That Actually Take Out a Singapore Comms Room
Cooling failure over a long weekend. A chilled-water or condensate leak under a raised floor. Humidity climbing in a cabinet that lost its air conditioning on Friday evening. An unlogged visit to an open rack. None of these announce themselves on a server console, and none of them are visible to a UPS.
The Rack Monitor 250 covers all of them from one IP address: temperature, humidity, spot fluid leak, smoke, door contact, dry contact and 0 to 5 V sensor types are all supported, with configurable thresholds driving e-mail alerts and SNMP traps.
Badged Access Control for Two Rack Doors
Rack door access control matters for anyone answering an audit question about physical access to systems holding regulated data. The NBRK0250A supports badged access control for two rack doors, so entry to the cabinet is authorised and logged rather than assumed - useful where physical access to a cabinet has to be authorised and logged, and for shared or colocated cabinets where several parties hold keys.
Door switch sensors (NBES0302 and NBES0303) cover the simpler case where you only need to know that a door was opened.
Integrates With EcoStruxure, SNMP, Modbus and Your Existing NMS
Access is over a single 10/100 Base-T Ethernet port with HTTP, HTTPS, SNMPv1 and SNMPv3, SMTP, FTP, SSH, Telnet, NTP, RADIUS, IPv4 and IPv6, and Modbus over both TCP and serial. Schneider's EcoStruxure Data Center Expert and EcoStruxure IT platforms are supported for estate-wide monitoring.
The unit also provides a beacon port for an AP9324 alarm beacon, a switched outlet rated 10 A total, and a 12 VDC / 24 VDC auxiliary output at 75 mA. Note that it is not a PoE-powered device - Schneider's user guide states this explicitly - so plan a 100 to 240 VAC feed at the rack. Running that feed from a UPS-backed outlet keeps monitoring alive through the outage you most want it for.
APC NBRK0250A Datasheet — Technical Specifications
General
| Part Number (SKU) | NBRK0250A |
| Schneider Electric Product Name | Rack Mount, Security and Environmental Appliance, NetBotz, 250A |
| Documentation Name | NetBotz Rack Monitor 250 with NMC3 |
| Form Factor | 1U rack-mount appliance |
| Sensor Capacity | Up to 42 wired sensors and 47 wireless sensors |
| Access Control | Badged access control for 2 rack doors |
| TAA Compliant | Yes |
| EAN | 731304563365 |
| Warranty | 2-Year Manufacturer Warranty (APC by Schneider Electric) |
| Local Warranty (Singapore) | Yes - supplied and supported locally by SourceIT |
Function & Connectivity
| Universal Sensor Ports | 6 on the appliance |
| Sensor Types Supported | Temperature, humidity, door contact, dry contact, spot fluid leak, smoke, 0 to 5 V |
| Network Port | 1 x RJ-45, 10/100 Base-T (IEEE 802.3 / 802.3u) |
| Power over Ethernet | Not supported - the Rack Monitor 250 is not a PoE device |
| A-Link Ports | For cascading sensor pods and AP9520TH display sensors |
| Beacon Port | Supports the AP9324 alarm beacon |
| Switched Outlet | 1, 10 A maximum total |
| USB Port | 1 - used by the NBWC100U Wireless Network Coordinator |
| Auxiliary Voltage Output | 12 VDC / 24 VDC at 75 mA |
| Protocols | HTTP, HTTPS, SNMPv1, SNMPv3, SMTP, FTP, SSH, Telnet, NTP, RADIUS, TCP/IP v4 and v6, Modbus TCP and Modbus serial |
| Management Platforms | EcoStruxure Data Center Expert, EcoStruxure IT |
Physical & Environmental
| Dimensions (H x W x D) | 44 x 432 x 59 mm |
| Net Weight | 1.27 kg |
| Packaged Weight | 2.95 kg |
| Power Input | 100 to 240 VAC |
| Operating Temperature | 0 to 45 °C |
| Storage Temperature | -15 to 65 °C |
| Compliance | EU RoHS (with exemptions), REACh, China RoHS |
| Package Contents | Appliance, installation guide, rack mounting brackets, temperature and humidity sensor, installation gasket |
Compatibility & Fit
Which sensors the Rack Monitor 250 accepts. Six universal sensor ports are on the appliance, and the user guide names these APC sensor part numbers:
| AP9335T | Temperature sensor - not stocked, available to order |
| AP9335TH | Temperature and humidity sensor, RJ45, 3.9 m lead - stocked by SourceIT |
| AP9520TH | Temperature and humidity sensor with display, connects over A-Link |
| NBES0301 | Spot fluid leak sensor |
| NBES0302 / NBES0303 | Door switch sensors |
| NBES0304 | Dry contact cable |
| NBES0305 | 0 to 5 V sensor cable |
| NBES0306 | Vibration sensor |
| NBES0307 | Smoke sensor |
Sensor part numbers other than the AP9335TH are not stocked SourceIT lines - tell us which risks you need to cover and we will quote the set.
How far it scales. Six ports directly on the unit, rising to up to 42 wired sensors as sensor pods are cascaded over A-Link, plus up to 47 wireless sensors when the NBWC100U Wireless Network Coordinator occupies the USB port. That is a row-level capability, not a single-rack one.
Power and mounting. 1U of rack space, 44 x 432 x 59 mm, 1.27 kg, and a 100 to 240 VAC input. It is not a PoE device, so it needs a local outlet - put it on a UPS-backed circuit so monitoring survives the mains event it is there to report. Rack mounting brackets are supplied.
Network and integration. One 10/100 Base-T Ethernet port. Monitoring integrates over SNMPv1 and SNMPv3, HTTPS and e-mail, into EcoStruxure Data Center Expert or EcoStruxure IT, or into an industrial or building system over Modbus TCP or Modbus serial.
When a management card is enough instead. If all you need is temperature and humidity in one rack and you have a free SmartSlot in the UPS, an AP9641 with an AP9335TH is the cheaper answer. Step up to the NBRK0250A when you need more than two sensors, leak or smoke detection, door access control, or monitoring that is independent of any one UPS.
Package Contents & APC NetBotz Ordering Information
In the box: NetBotz Rack Monitor 250 appliance, installation guide, rack mounting brackets, temperature and humidity sensor, installation gasket.
APC environmental monitoring options in the SourceIT catalogue
| Model | Scope |
| NBRK0250A (this listing) | 1U appliance - 6 sensor ports, up to 42 wired and 47 wireless sensors, badged access control for 2 rack doors |
| AP9641 | UPS SmartSlot card - network management plus 2 universal I/O sensor ports |
| AP9613 | UPS SmartSlot card - 2 universal I/O ports plus 4 dry contact inputs and 6 output relays, no network |
| AP9640 | UPS SmartSlot card - network management only, no sensor ports |
Sensors
| AP9335TH | Temperature and humidity sensor, RJ45, 3.9 m lead - stocked |
| AP9335T / AP9520TH / NBES0301-0307 | Temperature, display sensor, leak, door, dry contact, 0-5 V, vibration and smoke sensors - available to order |
Racks and rack power to monitor
| AR106VI | NetShelter 6U low-profile wallmount enclosure, 230 V fans |
| AP8853 | NetShelter Metered Rack PDU, 0U, 32 A, 42 outlets - has its own environmental sensor port |
Datasheet & Downloads
Official Schneider Electric documentation for the APC NBRK0250A. Links open in a new tab.
- Schneider Electric product page - NetBotz Rack Monitor 250 (NBRK0250A)
- NetBotz Rack Monitor 250 installation and quick start guide (TME14429A_EN)
- NetBotz Rack Monitor 250 user guide (TME14430_EN)
Need a specific document, a compliance declaration or a written quotation? Contact SourceIT and we will supply it.
Frequently Asked Questions — APC NBRK0250A
How many sensors can the NBRK0250A handle?
Six universal sensor ports are on the appliance itself. Schneider states support for up to 42 wired sensors as sensor pods are cascaded over the A-Link ports, plus up to 47 wireless sensors when the NBWC100U Wireless Network Coordinator is fitted to the USB port. Six is the number you get out of the box; 42 is the ceiling with expansion.
Can it be powered over Ethernet?
No. Schneider's user guide states explicitly that the Rack Monitor 250 is not a PoE-compatible device. It takes a 100 to 240 VAC supply. Feed it from a UPS-backed outlet so the monitoring stays up during the mains event you want it to report on.
What is the difference between this and an AP9641 with a sensor?
Scale and independence. The AP9641 is a card in a UPS SmartSlot with two sensor ports - fine for temperature and humidity in one rack, and cheaper. The NBRK0250A is a standalone 1U appliance with six ports, expansion to 42 wired sensors, leak, smoke and vibration sensor support, badged access control for two rack doors, a beacon port and a switched outlet. Choose the appliance when the requirement is the rack or the row, not the UPS.
Does it do rack door access control?
Yes - badged access control for two rack doors is one of its headline functions, alongside door switch sensors (NBES0302 and NBES0303) for the simpler open-or-closed case. That is the feature that usually justifies it in an audited environment where physical access to a cabinet has to be authorised and logged.
Which network protocols does it speak?
HTTP, HTTPS, SNMPv1 and SNMPv3, SMTP for e-mail alerts, FTP, SSH, Telnet, NTP, RADIUS, TCP/IP v4 and v6, and Modbus over both TCP and serial. It also integrates with EcoStruxure Data Center Expert and EcoStruxure IT. The Ethernet port is 10/100 Base-T.
How much rack space does it take, and what ships with it?
1U, 44 x 432 x 59 mm, 1.27 kg. In the box: the appliance, installation guide, rack mounting brackets, a temperature and humidity sensor, and an installation gasket - so it monitors from the moment it is racked, before you add any further sensors.
Does it come with a Singapore warranty?
Yes. Every APC NBRK0250A sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the NBRK0250A with a 2-year manufacturer warranty.