APC Easy UPS SRV 2000VA 1800W 230V with Rail Kit
PRODUCT DESCRIPTION
APC Easy UPS On-Line SRV 2000VA/1800W Rackmount 2U UPS 230V with Rail Kit (SRV2KRIRK-E) - 2 Years Local Warranty
On-Line Double Conversion for Singapore's 230V/50Hz Supply
The APC Easy UPS On-Line SRV2KRIRK-E is a true double-conversion on-line UPS rated at 2000 VA / 1800 W. The load runs from the inverter continuously, on a clean 230 V sine wave with 3% maximum distortion, rather than waiting on a transfer when the mains misbehaves.
For a Singapore server room or comms cabinet that means the everyday problems — voltage sag during a storm, a brownout on a loaded riser, switching transients from lift or chiller plant — are absorbed by the rectifier rather than passed to your equipment, and the battery is held in reserve for a real outage.
0.9 Power Factor — More Real Watts per kVA
The -E generation is the 0.9 power factor build of the Easy UPS On-Line SRV range, and that is the main reason to choose it: the SRV2KRIRK-E delivers 1800 W from 2000 VA, where the equivalent earlier non-E model delivers less real power from the same VA rating. When you are sizing against a rack of servers, switches and storage, watts are the number that decides whether the UPS copes.
Size on the total continuous watts of the connected load with headroom for start-up surge, and talk to us if you are close to the limit — we would rather size it right than have it trip.
2U Rackmount with Rail Kit Included
The SRV2KRIRK-E occupies 2U of rack space and the carton includes both the rack mounting brackets and the support rails — the “RK” in the part number is exactly that. No separate rail kit needs to be ordered.
At 462 mm deep the chassis fits comfortably in a standard 600 mm comms cabinet, which is unusual at this rating and makes it a practical choice for an office riser cabinet as well as a proper server rack.
Outlets, Emergency Power Off and Network Management
Output is provided on 4 x IEC C13, so ordinary IEC power leads plug straight in — no electrician and no hardwiring required, unlike the larger 6 and 10 kVA models in the same range. The unit is supplied with the input cable and an IEC C13 to C14 lead in the box.
The -E generation adds an Emergency Power Off connector, using normally-closed contacts, which the earlier non-E models do not have — a genuine advantage where a room EPO loop is a condition of occupancy. An Intelligent Card Slot takes an AP9544 Network Management Card 3 for SNMP monitoring, and PowerChute Serial Shutdown handles graceful unattended shutdown over USB or serial.
Supplied Locally, with GST Invoice and Singapore Warranty
SourceIT supplies the SRV2KRIRK-E as an APC by Schneider Electric product with a full GST invoice and local Singapore warranty support. APC's manufacturer term for the Easy UPS On-Line SRV range is two years, repair or replace, applied worldwide with no separate European figure.
Not sure whether you need the -E build, the earlier non-E model or an extended-runtime version? Email sales@sourceit.com.sg with your load and the runtime you need and we will size it for you.
APC SRV2KRIRK-E Datasheet — Technical Specifications
General
| Schneider Electric Product Name | APC Easy UPS On-Line, 2000VA/1800W, Rackmount 2U, 230V, 4x IEC C13 outlets, Intelligent Card Slot, LCD, W/ rail kit |
| Part Number (SKU) | SRV2KRIRK-E |
| Range | APC Easy UPS On-Line SRV, -E generation |
| Topology | Double conversion on-line |
| Form Factor | Rackmount, 2U |
| Manufacturer Warranty | 2-Year Manufacturer Warranty (APC by Schneider Electric) |
| Local Warranty (Singapore) | Included with every unit supplied by SourceIT, together with a GST invoice |
Output
| Output Power Capacity | 2000 VA / 1800 W |
| Output Power Factor | 0.9 — the -E generation delivers more real watts than the 0.8 power factor of the earlier non-E SRV models |
| Nominal Output Voltage | 230 V, configurable to 220 V / 230 V / 240 V |
| Output Frequency | 50/60 Hz ±3 Hz synchronised to mains |
| Output Voltage Distortion | 3% |
| Output Waveform | Sine wave |
| Output Receptacles | 4 x IEC C13 |
| Efficiency | 88% at full load |
| Surge Energy Rating | 945 joules |
| Internal Bypass | Automatic and manual |
| Transfer Time | Not published by Schneider Electric for the -E generation — the load is fed continuously from the inverter |
Input
| Nominal Input Voltage | 230 V |
| Input Voltage Range (full load) | 180–285 V AC |
| Input Voltage Range (reduced load) | 110–285 V AC |
| Input Frequency | 40–70 Hz auto-sensing |
| Input Connection | IEC 60320 C14 inlet |
Batteries & Runtime
| Battery Type | Sealed maintenance-free lead-acid (VRLA), 3 to 5 year typical service life |
| Battery Bus Voltage | 48 V DC |
| Replacement Battery Cartridge | APCRBCV201 |
| Typical Recharge Time | 4 hours |
| External Battery Packs | Schneider's product name and datasheet for this model do not list external battery pack support. The extended-runtime models in this range (SRV1KRILRK-E, SRV2KRILRK-E and SRV3KRILRK-E) are the ones documented to take the SRV36RLBP-9A / SRV72RLBP-9A packs, up to four per UPS. Please confirm with SourceIT before planning extended runtime around this part number. |
| Runtime at Load | Not published by Schneider Electric as a figure for this model — runtime depends on the connected load; ask us for a sizing calculation |
Communications & Management
| Communication Ports | USB (Type B), RS-232 serial, EPO connector, Intelligent Card Slot (1 slot, free) |
| Emergency Power Off (EPO) | Yes — EPO connector with normally-closed contacts on pins 1 and 2 |
| Control Panel | Multifunction LCD |
| Network Management | Optional AP9544 Network Management Card 3, fitted in the Intelligent Card Slot |
| Shutdown Software | PowerChute Serial Shutdown |
Physical & Environmental
| Rack Height | 2U |
| Dimensions (H x W x D) | 86 x 438 x 462 mm |
| Net Weight | 18.8 kg |
| Shipping Weight | 22.5 kg |
| Audible Noise | 50 dBA |
| Heat Dissipation | 759 BTU/hour |
| Ingress Protection | IP20 |
| Finish | Black, RAL 7010 |
| Operating Environment | 0–40 °C, 0–95% relative humidity non-condensing, 0–3000 m |
| Storage Environment | −20 to 50 °C, 0–15000 m |
| Certifications | CE, UKCA, TISI |
| Safety Standards | EN/IEC 62040-1:2019/A11:2021; EN/IEC 62040-2:2006/AC:2006; EN/IEC 62040-2:2018 |
| Package Contents | IEC C13 to Schuko input cable, IEC C13 to C14 cable, USB cable, RS-232 serial cable, rack mounting brackets and rack mounting support rails, user documentation |
Compatibility & Runtime
Outlets and What Can Be Plugged In
The SRV2KRIRK-E provides 4 x IEC C13 on the output. Standard IEC leads plug straight in, so no electrician is needed for the load side. The input connection is an IEC C14 inlet and the appropriate input cable is supplied in the box along with an IEC C13 to C14 lead.
Size on watts, not on VA. This unit is a 0.9 power factor build rated at 1800 W. Add up the continuous draw of everything you intend to connect, leave headroom for start-up surge, and check the total against that figure. We are happy to do the sum for you.
Rack Fit
The chassis occupies 2U and measures 86 x 438 x 462 mm, so at 462 mm deep it fits a standard 600 mm comms cabinet comfortably. Both the rack mounting brackets and the support rails are supplied in the carton, so no separate rail kit is required.
Battery and Runtime
The battery is a sealed maintenance-free VRLA type with a typical three to five year service life in normal conditions. Singapore's humidity and ambient temperature both shorten battery life, so a cabinet that stays close to 25 °C will get materially more service out of a battery than one that sits at 35 °C. The replacement cartridge for this model is APCRBCV201 — note that the -E generation uses different cartridge part numbers from the earlier non-E models, so check the part number against your actual unit before ordering.
Schneider's product name and datasheet for this model do not list external battery pack support. The extended-runtime models in this range (SRV1KRILRK-E, SRV2KRILRK-E and SRV3KRILRK-E) are the ones documented to take the SRV36RLBP-9A / SRV72RLBP-9A packs, up to four per UPS. Please confirm with SourceIT before planning extended runtime around this part number.
Schneider does not publish a runtime table for this model, so we do not print one. Runtime depends on the connected load. Send us your load in watts and the hold-up time you need and we will size it for you.
Management and Software
An Intelligent Card Slot takes an AP9544 Network Management Card 3 for SNMP monitoring and alerting. PowerChute Serial Shutdown is the documented software for graceful unattended shutdown over the USB or RS-232 port. An EPO connector with normally-closed contacts is fitted, which the earlier non-E generation does not have.
Package Contents & Easy UPS On-Line SRV Ordering Information
In the Box
IEC C13 to Schuko input cable, IEC C13 to C14 cable, USB cable, RS-232 serial cable, rack mounting brackets and rack mounting support rails, user documentation
Easy UPS On-Line SRV -E Range Ordering Information
| SRV2KI-E | 2 kVA / 1800 W | Tower | 4 x C13 |
| SRV3KI-E | 3 kVA / 2700 W | Tower | 6 x C13, 1 x C19 |
| SRV2KRIRK-E (this listing) | 2 kVA / 1800 W | Rackmount 2U, rail kit | 4 x C13 |
| SRV3KRIRK-E | 3 kVA / 2700 W | Rackmount 2U, rail kit | 6 x C13, 1 x C19 |
| SRV1KRILRK-E | 1 kVA / 900 W | Rackmount 4U, rail kit | 4 x C13, extended runtime |
| SRV2KRILRK-E | 2 kVA / 1800 W | Rackmount 4U, rail kit | 4 x C13, extended runtime |
| SRV3KRILRK-E | 3 kVA / 2700 W | Rackmount 4U, rail kit | 6 x C13, 1 x C19, extended runtime |
Replacement Battery Cartridges
The -E generation uses the APCRBCV cartridge series. Cartridge numbers differ between the tower and rackmount builds and between generations, so match the cartridge to the exact part number on your unit.
| APCRBCV204 | Replacement cartridge for the SRV2KI-E tower |
| APCRBCV205 | Replacement cartridge for the SRV3KI-E tower |
| APCRBCV201 | Replacement cartridge for the SRV2KRIRK-E rackmount |
| APCRBCV202 | Replacement cartridge for the SRV3KRIRK-E rackmount |
| AP9544 | Network Management Card 3 for the Intelligent Card Slot |
None of these cartridges is currently held in stock — email sales@sourceit.com.sg with your part number and we will source it.
The Earlier Non-E Models
The same ratings in the earlier 0.8 power factor generation are also in our catalogue. They deliver fewer real watts per kVA and have no EPO connector, but remain a sound choice where neither matters.
| SRV1KI | 1 kVA / 800 W | Tower |
| SRV2KI | 2 kVA / 1600 W | Tower |
| SRV3KI | 3 kVA / 2400 W | Tower |
| SRV1KRI + SRVRK1 | 1 kVA / 800 W | Rackmount 2U |
| SRV2KRI + SRVRK1 | 2 kVA / 1600 W | Rackmount 2U |
| SRV3KRI + SRVRK1 | 3 kVA / 2400 W | Rackmount 2U |
Datasheet & Downloads
Schneider Electric hosts the official documentation for this product. The link below is the product page we verified resolves and shows the correct part number.
| Schneider Electric product page | APC SRV2KRIRK-E on se.com — Singapore site |
Schneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email sales@sourceit.com.sg quoting SRV2KRIRK-E and we will send you the current PDF datasheet and user manual directly.
The governing document for the standard -E models is Schneider user manual EUO-UM-990-91498A-MN01_EN.
Frequently Asked Questions — APC SRV2KRIRK-E
What is the difference between the VA and the watt rating, and how do I size this UPS?
VA is apparent power and watts is real power; the watt rating is what limits your load. The -E generation is a 0.9 power factor build, so this model gives 1800 W from 2000 VA — more real power than the earlier non-E model of the same VA rating. Total up the continuous watts of everything you want to protect, allow headroom for start-up surge and growth, and compare that to 1800 W.
What does the “-E” suffix actually change?
Three things that matter. The output power factor rises from 0.8 to 0.9, so you get more real watts from the same VA rating. An Emergency Power Off connector is fitted, which the non-E models do not have. And the replacement battery cartridge part numbers change, so a cartridge from a non-E unit is not the right part for an -E unit. Everything else — on-line double conversion, the two-year warranty, the Intelligent Card Slot — carries over.
Is the output a true sine wave, and will it suit an active-PFC server power supply?
Yes. This is an on-line double-conversion UPS with a sine wave output and 3 per cent maximum distortion, generated by the inverter continuously rather than switched in. That is the output type active-PFC power supplies in servers and modern workstations are designed for, and it is a genuinely different proposition from the step-approximated output of an entry-level standby UPS.
What runtime will I get?
Schneider does not publish a runtime figure for this model that we can verify, so we will not print one. Runtime falls sharply as load rises. Email sales@sourceit.com.sg with your load in watts and the hold-up time you need and we will size it against the manufacturer's runtime curve.
Which replacement battery cartridge does it take, and can I change it myself?
This model takes the APCRBCV201 cartridge. Schneider describes the batteries as user replaceable. Schneider does not describe this model as hot-swappable, so we do not claim it is — plan on a short shutdown window for a battery change unless we confirm otherwise for your build. Because the -E cartridge numbers differ from the non-E ones, always check the part number printed on the unit before ordering.
How much rack space does it need, and is a rail kit included?
It occupies 2U, and both the mounting brackets and the support rails are in the carton — that is what the RK in the part number means, so there is no separate rail kit to order. At 462 mm deep it fits a standard 600 mm comms cabinet.
How does this compare with the other models in our catalogue?
Within the -E generation, the choice is rating and form factor: the 2 kVA models give 1800 W on 4 x C13, the 3 kVA models give 2700 W on 6 x C13 plus a C19. Against the earlier non-E models of the same VA rating, the -E gives more real watts and adds EPO. And if you need runtime measured in tens of minutes rather than minutes, the extended-runtime -E models ship with an external battery pack and accept up to four.
How do I monitor it and shut servers down safely?
An Intelligent Card Slot takes an AP9544 Network Management Card 3 for SNMP monitoring and alerting over the network. For a directly attached server, PowerChute Serial Shutdown is the documented software and connects over the supplied USB or RS-232 cable.
Does it come with a Singapore warranty and a GST invoice?
Yes. Every APC SRV2KRIRK-E sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRV2KRIRK-E with a 2-year manufacturer warranty.