Rising component costs may adjust prices on selected items without prior notice. Supply constraints may add shipping time — we’ll notify you if affected. OEM costs and supply tightening — contact us to secure stock and pricing. For projects or bulk orders, choose “Request for Quotation” on any item.
Call our specialists(65) 6978 3502 Email our sales teamsales@sourceit.com.sg

APC Smart-UPS SRT 48V 1kVA 1.5kVA RM Battery Pack

SKU: SRT48RMBP

  • S$1,329.40
    Unit price per 
  • Save S$266.80
Shipping calculated at checkout.

PRODUCT DESCRIPTION

APC Smart-UPS SRT 48V 1kVA 1.5kVA RM Battery Pack (SRT48RMBP) - 2 Years Local Warranty

Extended Runtime for APC Smart-UPS SRT 1 kVA and 1.5 kVA models

The APC APC Smart-UPS SRT 48V 1kVA 1.5kVA RM Battery Pack (SRT48RMBP) is an external battery pack for the APC Smart-UPS On-Line SRT range. It connects to the UPS 48V DC battery bus and extends how long the protected load stays up during a mains failure — the difference between a graceful shutdown and a rack full of servers dropping mid-write. APC's installation guide confirms this pack is used with Smart-UPS SRT 1 kVA and 1.5 kVA models. It is a runtime accessory, not a standalone power source: it has no outlets of its own and must be connected to a compatible SRT UPS.

Connect Up To Ten Packs on One UPS

APC states that the UPS will recognise as many as ten external battery packs. Runtime scales close to linearly with each pack added, so a single SRT can be built out from minutes of autonomy to hours where a site has no generator. Bear in mind that recharge time increases with every pack added — a bank that has been fully discharged takes correspondingly longer to return to full capacity, which matters if your site sees repeated outages in a single storm.

User-Replaceable VRLA Battery Modules

The SRT48RMBP carries two sealed, maintenance-free, valve-regulated lead-acid (VRLA) battery modules that slide out on handles for replacement, and the replacement cartridge part number is APCRBC155. APC rates the batteries at two to five years of typical service life and recommends replacement at least every five years. In Singapore, ambient temperature is the dominant factor: a pack sitting in an unconditioned comms cupboard will not last as long as one in a cooled server room, so plan cartridge budget accordingly.

Rack-Mounted, 2U (85 mm), Rails Included

The SRT48RMBP is the rackmount build: it occupies 2U (85 mm) in a standard 19-inch cabinet and ships with rail kit and rack mounting brackets. Dimensions are 85 mm (H) x 432 mm (W) x 536 mm (D). Battery packs are heavy — mount them at the bottom of the cabinet, below the UPS, and check the cabinet's static load rating before stacking several. The SRT48BP tower variant is available where there is no rack.

Supplied Locally with GST Invoice

SourceIT supplies the SRT48RMBP from Singapore with a GST invoice and local warranty support. Ordering the battery pack together with the UPS is usually the sensible approach — it avoids a second delivery and a second rack visit, and lets the whole bank be commissioned and load-tested in one go.

APC SRT48RMBP Datasheet — Technical Specifications

General

Part Number (SKU) SRT48RMBP
Manufacturer Product Name APC Smart-UPS SRT 48V 1kVA 1.5kVA RM Battery Pack
Brand APC by Schneider Electric
Product Type External battery pack (extended runtime) for Smart-UPS On-Line SRT
Form Factor Rackmount 2U
GTIN / UPC 731304298248

Battery Specifications

Nominal Battery Voltage 48 V DC
Battery Type Sealed, maintenance-free, valve-regulated lead-acid (VRLA)
Battery Modules 2, user-replaceable
Replacement Battery Cartridge APCRBC155
Typical Service Life 2 to 5 years; APC recommends replacement at least every 5 years
Maximum Packs per UPS Up to 10 recognised by the UPS
Compatible UPS Models Smart-UPS SRT 1 kVA and 1.5 kVA models

Physical & Environmental

Dimensions (H x W x D) 85 mm (H) x 432 mm (W) x 536 mm (D)
Net Weight 31.5 kg (installation guide JGNY-AAY9G9, without packaging); the SRT48RMBP product datasheet states 29.9 kg
Rack Height 2U (85 mm)
Rail Kit / Brackets Rail kit and rack mounting brackets included
Operating Temperature 0 to 40 °C
Storage Temperature -15 to 45 °C
Operating Relative Humidity 0 to 95%, non-condensing
Operating Altitude 0 to 3,000 m (0 to 10,000 ft)
Ingress Protection IP20
Manufacturer Warranty 3 years UPS electronics / 2 years battery (APC by Schneider Electric)
Local Warranty (Singapore) 2 years, supplied and supported by SourceIT Pte Ltd
Compatibility & Runtime

Which UPS models does the SRT48RMBP fit? APC's installation guide specifies this pack for Smart-UPS SRT 1 kVA and 1.5 kVA models. In the SourceIT catalogue that is:

SRT1000XLI 1,000 VA / 1,000 W · Tower
SRT1000RMXLI 1,000 VA / 1,000 W · Rackmount 2U
SRT1500XLI 1,500 VA / 1,500 W · Tower
SRT1500RMXLI 1,500 VA / 1,500 W · Rackmount 2U

It will not work with SRT units on a different battery bus voltage — the 3 kVA models use 96V (SRT96BP / SRT96RMBP) and the 5 kVA and larger models use 192V (SRT192BP family). Match the pack to the UPS battery voltage, not to the physical size of the cabinet.

How many can I connect? Up to ten packs are recognised by the UPS. Runtime scales with each pack added; so does recharge time.

Runtime. Actual runtime depends entirely on the connected load, on battery age and on ambient temperature, so no single figure applies. Schneider publishes per-model runtime tables with one to four packs connected in the SRT brochure linked in the Downloads section below.

Outlets. None. This is a battery pack, not a PDU — the load stays plugged into the UPS.

Rack fit. Occupies 2U (85 mm); dimensions 85 mm (H) x 432 mm (W) x 536 mm (D). Rail kit and brackets are in the box. Mount low in the cabinet and check the static load rating.

Package Contents & Smart-UPS SRT Ordering Information

In the box: Front bezel, ground cable, tie brackets and screws, rail kit and rack mounting brackets with hardware, battery cable connector screw, user documentation

Smart-UPS SRT external battery pack range

SRT48BP 48 V, SRT 1 kVA / 1.5 kVA · Tower
SRT48RMBP (this listing) 48 V, SRT 1 kVA / 1.5 kVA · Rackmount 2U
SRT72BP 72 V, SRT 2.2 kVA · Tower
SRT72RMBP 72 V, SRT 2.2 kVA · Rackmount 2U
SRT96BP 96 V, SRT 3 kVA · Tower
SRT96RMBP 96 V, SRT 3 kVA · Rackmount 2U
SRT192BP 192 V, SRT 5 kVA / 6 kVA · Tower
SRT192RMBP 192 V, SRT 5 kVA / 6 kVA · Rackmount
SRT192BP2 192 V, SRT 8 kVA / 10 kVA · Tower
SRT192RMBP2 192 V, SRT 8 kVA / 10 kVA · Rackmount

Compatible Smart-UPS SRT units at SourceIT

SRT1000XLI 1,000 VA / 1,000 W · Tower
SRT1000RMXLI 1,000 VA / 1,000 W · Rackmount 2U
SRT1500XLI 1,500 VA / 1,500 W · Tower
SRT1500RMXLI 1,500 VA / 1,500 W · Rackmount 2U

Replacement battery cartridge

APCRBC155 Replacement battery cartridge for the SRT48RMBP
Datasheet & Downloads
Frequently Asked Questions — APC SRT48RMBP

Which APC UPS models does the SRT48RMBP work with?
APC specifies it for Smart-UPS SRT 1 kVA and 1.5 kVA models. In our catalogue those are SRT1000XLI, SRT1000RMXLI, SRT1500XLI, SRT1500RMXLI. The pack connects to the UPS 48V DC battery bus — it is not interchangeable with the 96V or 192V packs used by the larger SRT units.

How much extra runtime will one pack give me?
That depends entirely on the load. Runtime roughly scales with the number of packs, but the starting point is your actual wattage draw, so a lightly loaded UPS gains far more minutes than a fully loaded one. Schneider's SRT brochure carries per-model runtime tables for one to four packs; the link is in the Downloads section above.

Can I connect more than one SRT48RMBP?
Yes — APC states the UPS will recognise as many as ten external battery packs. Remember that recharge time grows with the bank, and that the cabinet needs to carry the weight: battery packs are the heaviest thing in most racks.

Does the SRT48RMBP have outlets I can plug equipment into?
No. It is a battery pack only. All load equipment stays connected to the UPS; the pack simply extends how long the UPS inverter can keep running.

What replacement battery cartridge does it take, and can I fit it myself?
The SRT48RMBP uses the APCRBC155 cartridge. The modules are user-replaceable — the front bezel removes and the modules slide out on handles. APC rates typical service life at two to five years and recommends replacement at least every five years.

What is the difference between the SRT48RMBP and the SRT48BP?
Electrically they are the same 48V pack for the same UPS models. The difference is mechanical: the SRT48BP is the tower build with stabiliser hardware, the SRT48RMBP is the rackmount build with rail kit and brackets included. Order the one that matches how the UPS itself is installed.

Is the SRT48RMBP covered by warranty in Singapore?
Yes. Every APC SRT48RMBP sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRT48RMBP with a 3 years UPS electronics / 2 years battery manufacturer warranty.


We Also Recommend

APC Easy UPS On-Line SRV 1000VA RM 230V with Battery Pack, Rail Kit (SRV1KRILRK-E) - SourceIT

APC Easy UPS SRV 1000VA RM 230V with Battery Pack

Regular price S$19,453.40
APC Smart-UPS RT 20kVA 230V International (SRTG20KXLI) - SourceIT

APC Smart-UPS RT 20kVA 230V International

Sale price S$15,180.00
Save S$7,911.08
APC Smart-UPS RT 15kVA 230V International (SRTG15KXLI) - SourceIT

APC Smart-UPS RT 15kVA 230V International

Sale price S$13,022.60
Save S$1,656
APC Smart-UPS SRT 10000VA RM 230V (SRT10KRMXLI) - SourceIT

APC Smart-UPS SRT 10000VA RM 230V

Sale price S$8,910.20
Save S$1,784.80
APC Smart-UPS SRT 8000VA RM 230V (SRT8KRMXLI) - SourceIT

APC Smart-UPS SRT 8000VA RM 230V

Sale price S$7,539.40
Save S$3,921.96