APC NetShelter 9000 Switched Rack PDU 0U 16A 230V 24 Outlets IEC 309 Cord - SourceIT

APC NetShelter 9000 Switched Rack PDU 0U 16A 230V 24 Outlets IEC 309 Cord

SKU: APDU9959EU3

  • S$1,568.60
    Unit price per 
Shipping calculated at checkout.

PRODUCT DESCRIPTION

APC NetShelter Switched Rack PDU, 9000 Series, 0U, 16A, 230V, 21 C13 & 3 C19 Outlets, IEC 309 Cord (APDU9959EU3) - 2 Years Local Warranty

Twenty-Four Switched Outlets on a 16 A Commando Feed

The APC NetShelter Switched Rack PDU APDU9959EU3 is the 16 A member of the 9000 series for 230 V racks: twenty-one IEC C13 and three IEC C19 outlets, each individually switchable over the network, rated 3,700 VA. The "EU3" suffix means it ships with a 3 m locking input cord that ends in an IEC 60309 16 A 2P+E plug - the blue commando connector found on row PDUs and busway tap-offs in Singapore data centres - plugged into the strip's C20 inlet.

It is the strip to specify when a rack has a 16 A feed and you want remote power-cycling on every outlet without paying for 32 A capacity you cannot use.

Remote Switching, Sequencing and Alarms

Any outlet can be switched on, off or power-cycled from the built-in web, SNMP or SSH interface or through EcoStruxure IT, so a hung switch in a colocation cage is fixed from your desk. Power-on sequencing and delays keep a rack from drawing its full inrush at once after an outage, and alarm thresholds on the metered load warn you before the 16 A limit is reached. A one-year Secure Network Management Card subscription is included.

9000-Series Platform: Gigabit Ethernet, NMC3, LCD, Sensor Port

The 9000 series is Schneider's current NetShelter switched platform: a Gigabit Ethernet management port on the NMC3 architecture, a local LCD with buttons for current, power and voltage, a USB port, a universal I/O port for environmental sensors, and Network Port Sharing that lets one network connection manage a group of 9000-series strips through their Link A and Link B ports. Outlets are hybrid C13/C15 and C19/C21 types with a locking feature for APC locking cords, and each has a green LED that shows when it is energised.

1,794 mm Long and 5.6 kg

The APDU9959EU3 is 1,794 mm long, 55 mm wide and 46 mm deep, weighing 5.61 kg - a full-height 0U unit for a 42U enclosure with a rear vertical channel, mounted toolless with the supplied brackets and consuming no rack units.

APC APDU9959EU3 Datasheet — Technical Specifications

General

Product Name APC NetShelter Switched Rack PDU, 9K series, 0U, 16A, 230V, 21 C13 and 3 C19 outlets, IEC309 Cord
Part Number (SKU) APDU9959EU3
Product Type Switched Rack Power Distribution Unit (PDU), NetShelter 9000 series
Form Factor Zero U (0U), vertical side mount
Phase Single phase
Colour Black
Warranty 2-Year Manufacturer Warranty (APC by Schneider Electric)
Local Warranty Local Warranty (Singapore)

Input

Input Connection IEC 60320 C20 inlet, with supplied locking cord to IEC 60309 16 A 2P+E plug
Cord Length 3.0 m
Nominal Input Voltage 230 V
Acceptable Input Voltage 220-240 VAC
Input Frequency 50/60 Hz
Maximum Input Current 16 A
Maximum Load Capacity 3,700 VA (3.7 kW)

Output & Receptacles

Output Receptacles Twenty-one (21) IEC 60320 C13 and three (3) IEC 60320 C19 - 24 outlets total
Output Voltage 230 V
Maximum Total Current Draw 16 A
Outlet Type Hybrid C13/C15 and C19/C21 outlets with locking feature for APC locking cords; per-outlet status LED

Metering, Switching & Management

Outlet Switching Individual on/off control of every outlet over the network, with power-on sequencing and delays
Metering Current, power and voltage for the PDU, shown on the LCD and over the network
Local Display LCD with input buttons
Network Management Built in - NMC3 platform, Gigabit Ethernet (10/100/1000BASE-T)
Management Interfaces Web, SNMP, SSH, EcoStruxure IT
Management Platform EcoStruxure IT. A one-year Secure Network Management Card subscription is included
Network Port Sharing Link A and Link B ports - manage a group of 9000-series Rack PDUs through one network connection
Additional Ports USB port; universal I/O port for environmental sensors
Surge Protection Not provided - no surge suppression is specified for this product

Physical & Environmental

Rack Height 0U
Dimensions (H x W x D) 1,794 x 55 x 46 mm
Net Weight 5.61 kg
Shipping Weight 8.59 kg
Mounting Toolless vertical mounting; rack mounting brackets included
Operating Temperature -5 to 45 °C
Storage Temperature -25 to 65 °C
Operating Humidity 5 to 95%
Operating Elevation 0 to 3,048 m
Approvals EAC, RCM, VDE
EMC FCC Part 15 Class A, ICES-003, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3
RoHS / REACh RoHS compliant with exemptions; REACh declaration available
Compatibility & Rack Fit

What you can plug into it. Twenty-one IEC C13 outlets for C14-corded servers, switches and appliances, and three IEC C19 outlets for C20-corded storage or larger switches. The hybrid outlets also accept C15 and C21 plugs, and the locking feature works with APC locking cords.

Load planning. 16 A total, 3,700 VA at 230 V, shared by twenty-four outlets. The PDU meters its load and lets you set an alarm threshold, so you see the headroom rather than guess it. A rack of dual-PSU servers usually wants two 16 A strips on A and B feeds, or the 32 A APDU9953.

Feeding it. The supplied 3 m locking cord plugs into the strip's C20 inlet and ends in an IEC 60309 16 A 2P+E commando plug, so the rack needs a 16 A commando socket on a row PDU, busway or fixed outlet. If the rack has a C19 outlet on a UPS instead, tell us - the same strip can be fed with a C19-to-C20 lead.

Rack fit. A 0U strip 1,794 mm long, 55 mm wide and 46 mm deep, weighing 5.61 kg. It needs a full-height enclosure with a rear vertical channel and mounts toolless, consuming no rack units. For a short cabinet the 1U AP7921B gives eight switched C13 outlets at 16 A.

Management and sensors. Gigabit Ethernet on the NMC3 platform with Web, SNMP and SSH, reporting into EcoStruxure IT, plus Network Port Sharing so a row of 9000-series strips can share one uplink. The universal I/O port takes an APC environmental sensor; ask us to confirm the right sensor part for the 9000 series when you order. The AP9640 and AP9641 cards we sell are Smart-UPS accessories and are not used with this PDU.

What it does not do. No surge protection and no battery - a UPS upstream is still required. It is not metered per outlet; the 2G AP8659 provides per-outlet metering and switching at the same 16 A rating.

Package Contents & NetShelter 9000 and Switched Rack PDU Ordering Information

What's in the Box

  • 1 x APC NetShelter Switched Rack PDU 9000 series (APDU9959EU3)
  • 3 m locking input power cord, IEC 60309 16 A 2P+E plug
  • Rack mounting brackets
  • Installation guide
  • Safety guide

NetShelter 9000 & Switched Rack PDU Range — Ordering Information

Model Type Rating Input Outlets Form Factor
AP7920B Switched 230 V, 10 A, 2.3 kW IEC C14 inlet, 2.4 m cord (8) C13 1U
AP7921B Switched 230 V, 16 A, 3.7 kW IEC C20 inlet, 2.4 m cord (8) C13 1U
APDU9959EU3 (this listing) Switched (9000 series) 230 V, 16 A, 3.7 kW IEC C20 inlet, 3 m locking IEC 60309 16 A cord (21) C13, (3) C19 0U, 1,794 mm
APDU9953 Switched (9000 series) 230 V, 32 A, 7.4 kW Captive IEC 60309 32 A cord, 3 m (21) C13, (3) C19 0U, 1,829 mm
AP8659 Metered-by-Outlet + Switched (2G) 230 V, 16 A IEC C20 inlet (21) C13, (3) C19 0U, 1,829 mm
AP8653 Metered-by-Outlet + Switched (2G) 230 V, 32 A, 7.4 kW Captive IEC 60309 32 A cord, 3 m (21) C13, (3) C19 0U, 1,829 mm
AP8858EU3 Metered 230 V, 16 A, 3.7 kW 3 m locking cord, IEC 60309 16 A plug (18) C13, (2) C19 0U, 902 mm
EPDU1232S Switched (Easy Rack PDU) 230 V, 3-phase, 22 kW IEC 60309 3P+N+E See listing 0U

Locking Output Cords (Sold Separately)

These are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an output cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.

Part Number Description
AP8704S-WW APC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m
Datasheet & Downloads

Official Schneider Electric documentation for the APC APDU9959EU3. Links open in a new tab.

Schneider's own datasheet download links redirect to a host that has served wrong-model files, so email sales@sourceit.com.sg quoting the SKU for the PDF and we will send you the correct document.

Frequently Asked Questions — APC APDU9959EU3

What does the EU3 suffix mean?

That the strip ships with a 3 m locking input cord ending in an IEC 60309 16 A 2P+E commando plug, fitted to the strip's C20 inlet. It is the version for racks fed from 16 A commando sockets, which is the usual arrangement in Singapore data centres and colocation cages.

What is the capacity - some listings say 11 kW?

16 A and 3,700 VA at 230 V. That is what Schneider's specification sheet for the APDU9959EU3 prints, and it is what a 16 A single-phase feed can deliver. Any larger figure you may see against this part number belongs to a three-phase model in the same series.

Is it metered per outlet?

No. The APDU9959EU3 meters the PDU load and switches every outlet individually, but it does not report energy per outlet. If per-outlet metering is the requirement, the 2G AP8659 provides it at the same 16 A rating and outlet count.

What is Network Port Sharing?

A way of managing several 9000-series Rack PDUs through one network connection. The strips are cabled together through their Link A and Link B ports and appear under the one management interface, saving switch ports and IP addresses across a row.

Can I add a temperature and humidity sensor?

Yes - the 9000 series has a universal I/O port for APC environmental sensors. Ask us to confirm the right sensor part number for the 9000 series when you order.

Does it have surge protection?

No. Schneider's specification sheet for the APDU9959EU3 has no surge section, joule rating or clamping figure. Surge and sag protection belongs at a UPS upstream.

How does it compare with the APDU9953?

Same 9000-series platform and the same twenty-one C13 and three C19 outlets. The APDU9959EU3 is 16 A and 3.7 kW with a C20 inlet and a supplied locking IEC 60309 16 A cord, 1,794 mm long; the APDU9953 is 32 A and 7.4 kW on a captive IEC 60309 32 A cord, 1,829 mm long. Choose on the supply in the rack and the load you need to carry.

Do I need a network management card?

No. Management is built into the strip on the NMC3 platform with a one-year Secure Network Management Card subscription included. The AP9640 and AP9641 cards are Smart-UPS accessories and are not used with this PDU.

Does it come with local Singapore warranty and a GST invoice?

Yes. Every APC NetShelter Switched Rack PDU 9000 APDU9959EU3 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs the APDU9959EU3 with a 2-year manufacturer warranty.


We Also Recommend

APC Smart-UPS RT 20kVA 230V International - SourceIT

APC Smart-UPS RT 20kVA 230V International

Sale price S$15,180.00
Save S$7,911.08
APC Smart-UPS RT 15kVA 230V International - SourceIT

APC Smart-UPS RT 15kVA 230V International

Sale price S$13,022.60
Save S$1,656
APC Smart-UPS Ultra On-Line Lithium-Ion 5kVA 5kW 2U Rack/Tower 230V - SourceIT

APC Smart-UPS Ultra On-Line Lithium-Ion 5kVA 5kW 2U Rack/Tower 230V

Regular price S$9,227.60