APC Smart-UPS SRT 192V 8 and 10kVA RM Battery Pack
PRODUCT DESCRIPTION
APC Smart-UPS SRT 192V 8 and 10kVA RM Battery Pack (SRT192RMBP2) - 2 Years Local Warranty
Rackmount Extended Runtime for the APC Smart-UPS SRT 8 kVA and 10 kVA On-Line Range
The APC SRT192RMBP2 is the 3U rackmount external battery pack (XLBP) for the largest units in the Smart-UPS SRT range. Schneider's installation guide 990-4811F-002 lists it against the SRT8KXLx, SRT8KRMXLx, SRT10KXLx and SRT10KRMXLx families, which share the ±192 V split battery architecture, the white battery connector and the APCRBC140 internal cartridge. At 8–10 kW the UPS is protecting a full production rack, and a battery pack is what turns a ride-through into real autonomy while a generator starts.
3U of Rack Space, Rail Kit and Brackets Included
The SRT192RMBP2 ships with the rail kit, a pair of rack-mount brackets, eight flat head screws, four ornamental screws and two cage nuts, so it drops straight into a 19-inch cabinet below the UPS. It is also two-post mountable. The chassis is 130 mm (H) x 432 mm (W) x 682.7 mm (D). At 91 kg the pack is heavier than most 2U servers by an order of magnitude — mount it at the very bottom of the cabinet, check the rack's static load rating before stacking several, and arrange proper handling before delivery day.
Up to Ten Packs on One UPS
Schneider states that the UPS will recognise as many as ten external battery packs connected to it, so runtime scales with rack space and budget. Recharge time increases with every pack added — worth planning for if your site sees repeated dips in a single afternoon, which is not unusual during the Singapore monsoon. Unlike the smaller 192 V pack, the BATT COMM battery communication cable is supplied with the 8 kVA and 10 kVA packs.
Keyed Connector — Order by Part Number, Not by Voltage
Schneider is explicit that each external battery pack has a keyed mating connector compatible only with its corresponding UPS, and APC does not support third-party packs. The SRT192RMBP2 will not connect to a 5 kVA or 6 kVA SRT — those take the SRT192BP or SRT192RMBP — and certainly not to a 3 kVA unit on the 96 V bus. Check your UPS part number against the compatibility list below before ordering. SourceIT supplies the SRT192RMBP2 from Singapore with a GST invoice and local warranty support.
APC SRT192RMBP2 Datasheet — Technical Specifications
General
| Part Number (SKU) | SRT192RMBP2 |
| Manufacturer Product Name | APC Smart-UPS SRT 192V 8kVA and 10kVA RM Battery Pack |
| Brand | APC by Schneider Electric |
| Product Type | External battery pack (XLBP) for Smart-UPS SRT, rackmount |
| Compatible UPS Family | SRT8KXLx / SRT8KRMXLx / SRT10KXLx / SRT10KRMXLx (Schneider installation guide 990-4811F-002 and FAQ FA349747) |
| Maximum Packs per UPS | 10 |
| GTIN | 731304292753 |
Battery Specifications
| Nominal Voltage | ±192 V |
| Battery Chemistry | Sealed, maintenance-free, valve-regulated lead-acid (VRLA) |
| Capacity | Schneider's product data sheet states 10 Ah; the family installation guide states 5 Ah per module across four modules. Both figures are quoted here as printed |
| Replacement Battery Cartridge | APCRBC140 (quantity 2) |
| Recharge Time | Not published for the pack — Schneider states only that recharge time increases for each pack added |
Physical & Environmental
| Dimensions | 130 mm (H) x 432 mm (W) x 682.7 mm (D) — 5.12 x 17.01 x 26.88 in |
| Rack Height | 3U |
| Mounting | Rack-mounted; two-post mountable |
| Net Weight | 91 kg (200.6 lb) |
| Rail Kit | Included — rail kit with instructions, 1 pair rack-mount brackets, 8 flat head screws, 4 ornamental screws, 2 cage nuts |
| Operating Temperature | 0 to 40 °C (32 to 104 °F) |
| Storage Temperature | -15 to 45 °C |
| Operating Relative Humidity | 0 to 95%, non-condensing (operating and storage) |
| Operating Altitude | 0 to 3,000 m (0 to 10,000 ft); storage to 15,240 m (50,000 ft) |
| Standards & Marks | OSHPD; recyclability 48% |
| Manufacturer Warranty | 2 years repair or replace (APC by Schneider Electric) |
| Local Warranty (Singapore) | 2 years, supplied and supported by SourceIT Pte Ltd |
Compatibility & Runtime
Which UPS models does the SRT192RMBP2 fit?
Schneider's installation guide 990-4811F-002 and compatibility FAQ FA349747 list the SRT192RMBP2 against the following Smart-UPS On-Line families, which share the ±192 V split battery architecture, the white battery connector and the APCRBC140 internal cartridge:
| SRT8KXLx | APC Smart-UPS SRT 8000VA on-line UPS, tower — including the SRT8KXLI stocked by SourceIT |
| SRT8KRMXLx | APC Smart-UPS SRT 8000VA on-line UPS, rackmount — including the SRT8KRMXLI stocked by SourceIT |
| SRT10KXLx | APC Smart-UPS SRT 10000VA on-line UPS, tower |
| SRT10KRMXLx | APC Smart-UPS SRT 10000VA on-line UPS, rackmount — including the SRT10KRMXLI stocked by SourceIT |
Schneider documents the compatibility as wildcard families (the “x” covers the regional build suffixes; the J-series variants take the SRT192RMBP2J pack instead) rather than as an exhaustive list of individual part numbers. If your UPS part number is not in one of the families above, send it to SourceIT and we will confirm against Schneider's table rather than guess.
Keyed connectors — packs are not interchangeable. Schneider states in FAQ FA349747 that “each external battery pack has a keyed mating connector that is only compatible with its corresponding UPS”. A 96 V pack will not physically connect to a 192 V UPS, and APC does not support third-party packs. Order strictly by the compatibility list above.
How many packs can I connect? Schneider states that the UPS will recognise as many as ten external battery packs connected to it. Recharge time increases with each pack added. Bear in mind what ten packs means physically: 30U of rack space and roughly 910 kg of battery, so cabinet capacity and floor loading normally set the practical limit well before the electronics do.
Rack fit. 3U, 130 mm (H) x 432 mm (W) x 682.7 mm (D), two-post mountable, with the rail kit, a pair of rack-mount brackets, eight flat head screws, four ornamental screws and two cage nuts included. At 91 kg, mount it at the very bottom of the cabinet and check the static load rating. The tower equivalent is the SRT192BP2.
Runtime. Runtime is not linear — halving the load more than doubles the time on battery. Schneider does not publish a runtime table for the SRT192RMBP2 that we are able to cite, so rather than quote a figure we cannot source, ask SourceIT for a runtime calculation against your measured load and pack count.
Cables. The BATT COMM battery communication cable is supplied with the SRT8K and SRT10K packs, so it is included here — unlike the SRT192BP for the 5 kVA and 6 kVA units, which does not include it.
Package Contents & Smart-UPS SRT Battery Pack Ordering Information
In the box (Schneider package contents): the battery pack, installation guide, warranty card, rack mounting brackets, rail kit with instructions, eight flat head screws, four ornamental screws, two cage nuts, front bezel, ground cable with two pan head screws, two tie brackets with four flat head screws, one pan head screw for the battery cable connector, and the BATT COMM battery communication cable.
Smart-UPS SRT external battery pack range at SourceIT
| SRT48BP / SRT48RMBP | 48 V · for SRT 1 kVA and 1.5 kVA · tower and rackmount |
| SRT72BP / SRT72RMBP | 72 V · for SRT 2.2 kVA · tower and rackmount |
| SRT96BP / SRT96RMBP | 96 V · for SRT 3 kVA · tower and rackmount |
| SRT192BP / SRT192RMBP | 192 V · for SRT 5 kVA and 6 kVA · tower and rackmount |
| SRT192BP2 / SRT192RMBP2 | ±192 V · for SRT 8 kVA and 10 kVA · tower and rackmount |
| SRTG192XLBP2 | ±192 V, 9 Ah · for SRTG 15 kVA and 20 kVA · rackmount 4U |
The 192 V packs at SourceIT
| SRT192BP | 192 V · for SRT 5 kVA and 6 kVA · tower |
| SRT192RMBP | 192 V · for SRT 5 kVA and 6 kVA · rackmount |
| SRT192BP2 | ±192 V · for SRT 8 kVA and 10 kVA · tower |
| SRT192RMBP2 (this listing) | ±192 V · for SRT 8 kVA and 10 kVA · rackmount 3U · rail kit included |
Matching UPS models and replacement cartridge
| SRT8KXLI | APC Smart-UPS SRT 8000VA 230V, tower |
| SRT8KRMXLI | APC Smart-UPS SRT 8000VA RM 230V, rackmount 6U |
| SRT10KRMXLI | APC Smart-UPS SRT 10000VA RM 230V, rackmount 6U |
| APCRBC140 | Replacement battery cartridge for the SRT 8 kVA and 10 kVA models and this pack (quantity 2) |
Datasheet & Downloads
Schneider Electric Singapore product page — SRT192RMBP2
Links open on Schneider Electric’s official product and document servers.
Frequently Asked Questions — APC SRT192RMBP2
Which UPS models does the SRT192RMBP2 fit?
Schneider lists it against the SRT8KXLx, SRT8KRMXLx, SRT10KXLx and SRT10KRMXLx families — the Smart-UPS SRT 8 kVA and 10 kVA on-line range, which shares the ±192 V split battery architecture, the white battery connector and the APCRBC140 internal cartridge. At SourceIT that means the SRT8KXLI, SRT8KRMXLI and SRT10KRMXLI.
Can I use an SRT192RMBP2 on a 5 kVA or 6 kVA SRT?
No. Those units take the SRT192BP (tower) or SRT192RMBP (rackmount). Despite the similar part numbers, the 8–10 kVA units use a ±192 V split battery architecture referenced to neutral, and Schneider fits keyed mating connectors so the wrong pack will not physically connect. Order by part number, not by the “192V” in the name.
What is the difference between SRT192RMBP2 and SRT192BP2?
They are the same pack in two builds for the same 8 kVA and 10 kVA UPS models. The SRT192RMBP2 is the rackmount version: 3U, two-post mountable, supplied with the rail kit, brackets, screws and cage nuts. The SRT192BP2 is the tower build.
How many packs can I connect to one UPS?
Schneider states the UPS will recognise as many as ten external battery packs. Be realistic about what that means: ten packs is 30U of rack space and roughly 910 kg of battery before you count the UPS itself, so cabinet capacity and floor loading normally set the limit. Recharge time also increases with each pack added.
How much runtime will one pack add?
That depends entirely on the load, and runtime is not linear — halving the load more than doubles the time on battery. Schneider does not publish a runtime table for this pack that we can cite, so rather than quote a figure we cannot source, ask SourceIT for a calculation against your measured load and the number of packs you are considering.
Which replacement cartridge does the pack take?
The APCRBC140, quantity 2 — the same cartridge family used inside the 8 kVA and 10 kVA UPS units themselves. The batteries are sealed, maintenance-free VRLA. Plan on replacement every three to five years; heat is the main determinant, so a cabinet that runs hot will shorten cartridge life.
How much rack space does it need, and is the rail kit included?
3U, and yes — the rail kit with instructions, a pair of rack-mount brackets, eight flat head screws, four ornamental screws and two cage nuts are all in the box, and the pack is two-post mountable. The chassis is 130 mm (H) x 432 mm (W) x 682.7 mm (D) and weighs 91 kg, so mount it at the very bottom of the cabinet and check the static load rating before stacking several.
Is the battery communication cable included?
Yes. Schneider supplies the BATT COMM battery communication cable with the SRT8K and SRT10K packs, so it is in the box with the SRT192RMBP2. Note that it is not included with the SRT192BP for the 5 kVA and 6 kVA units.
Is the SRT192RMBP2 covered by warranty in Singapore?
Yes. Every APC SRT192RMBP2 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRT192RMBP2 with a 2-year manufacturer warranty.