APC Replacement Battery Cartridge #133
PRODUCT DESCRIPTION
APC Replacement Battery Cartridge #133 for Smart-UPS SMT1500RM 2U Rackmount (APCRBC133) - 2 Years Local Warranty
Genuine APC Replacement Battery Cartridge #133
The APC Replacement Battery Cartridge #133 (APCRBC133) is the manufacturer's own replacement pack for the SMT1500RMI2U, and for the other APC units that specify this cartridge number. It arrives as a complete sealed lead-acid assembly with the correct connectors already fitted and, where the design calls for one, the metal battery tray, rated by Schneider Electric at 9 Ah per battery block. Fitting the genuine cartridge returns the unit to its designed backup capacity, and it keeps the question of whether a third-party pack affects your UPS warranty cover off the table entirely.
Why UPS Batteries Need Replacing in Singapore
Sealed lead-acid cells age faster in heat, and a comms cabinet or server room running warm will shorten a cartridge's working life well before its calendar age suggests. Schneider rates this cartridge for operation from 0 to 40 °C at up to 95% relative humidity, so a well-ventilated, air-conditioned rack is doing real work for your battery budget. The failure mode is the dangerous part: a UPS with a tired battery still shows a healthy front panel and still passes mains through, then drops the load the moment a PUB supply dip or a storm-season brownout actually arrives. If your unit has started reporting a battery fault, or has simply been in service for several years, replace the cartridge before you find out the hard way.
Exact-Fit Cartridge — Check Your Part Number First
This cartridge is specified for the SMT1500RMI2U. Its near-twin, the APCRBC159, is the same physical size and weight but is specified for the SMT1500RMI2UC, and Schneider states in writing that the two are not interchangeable: fit the wrong one and it will not secure properly on the battery retention screws. The difference is not the VA rating of the UPS but which build you have, so read the part number from the label on the rear of the unit rather than working from the capacity alone. Send it to us if you would like it checked before you order.
Local Singapore Stock, GST Invoice and Local Warranty
SourceIT holds APC replacement cartridges in Singapore, so a failed battery does not mean a multi-week import wait on a unit that is currently protecting nothing. Every order ships with a GST invoice for your accounts team and carries local Singapore warranty support, and we can quote the cartridge together with the matching UPS, rack PDU or network management card on a single purchase order. We can also arrange collection of the exhausted cartridge for proper lead-acid recycling when the replacement is delivered — ask for that when you order.
APC Replacement Battery Cartridge #133 (APCRBC133) Datasheet — Technical Specifications
General
| Product Type | APC Replacement Battery Cartridge (RBC) |
| Part Number (SKU) | APCRBC133 |
| Manufacturer | APC by Schneider Electric |
| Schneider Product Name | APC Replacement Battery Cartridge 133 with 2 Year Warranty |
| 2-Year Manufacturer Warranty (APC by Schneider Electric) | 2 years repair or replace, stated worldwide with no regional variation |
| Local Warranty (Singapore) | Supported locally by SourceIT Pte Ltd |
Battery Specifications
| Battery Chemistry | Leak-proof sealed lead-acid, maintenance-free |
| Nominal Voltage | Schneider's marketing name for this part carries a 24 V 9 Ah figure, but a cartridge weighing 11.96 kg in a 216 x 343 mm tray holds more blocks than that figure describes. No cartridge-level nominal voltage can be confirmed, so none is quoted here. Ask us before ordering if you need the terminal voltage confirmed in writing. |
| Capacity | 9 Ah per battery block |
| Expected Service Life | Not published by Schneider for this part number — ask us for field guidance |
| Operating Environment | 0 to 40 °C, 0 to 95% relative humidity (non-condensing), 0 to 10,000 ft |
| Storage Environment | -15 to 45 °C, 0 to 95% relative humidity (non-condensing) |
Physical & Environmental
| Dimensions | 83 x 216 x 343 mm (H x W x D) |
| Net Weight | 11.96 kg |
| Shipping Weight | 12.60 kg |
| EAN / GTIN | 0731304291282 |
| Package Contents | All required connectors pre-fitted, installation guide, battery recycling guide, metallic battery tray or enclosure, reusable packaging |
| Compliance | REACh declaration available. Schneider states EU RoHS "pro-active compliance" — the product itself sits outside the legal scope of EU RoHS. Packaging is at least 70% recycled cardboard. |
| Environmental | 84 kg CO2 eq. over the product lifecycle; 15% recycled plastic content |
Every figure above is taken from Schneider Electric's own published documentation for this exact part number. Where Schneider does not publish a value, the row says so rather than carrying a figure borrowed from a similar cartridge — APC ratings differ between parts that look identical.
Compatibility & Runtime
UPS models this cartridge is specified for. This is confirmed from Schneider FAQ000236099, which assigns APCRBC133 to the SMT1500RM2U and SMT1500RMI2U standard-build rack models.
| SMT1500RMI2U | APC Smart-UPS 1500VA Rackmount 2U 230V (standard build) |
This is the cartridge for the STANDARD SMT1500RM 2U build. The SmartConnect build — part numbers ending in C, such as the SMT1500RMI2UC — takes the APCRBC159 instead. Schneider states plainly that the two are not interchangeable, so check your unit's part number before ordering.
Electrical fit. Schneider does not publish a cartridge-level nominal voltage for this part — see the note in the specification table above. Selection is therefore made by UPS model number rather than by matching a voltage figure, which is how APC intends it to be done in any case. The charger, the runtime calculation and the low-battery cut-off inside the UPS are all set for one specific pack, so the model number is the only reliable way to order.
Runtime after replacement. A new cartridge restores the runtime the UPS was rated for when new; it does not add runtime beyond that. How long that actually is depends entirely on how heavily the UPS is loaded — a unit at a quarter load runs for considerably longer than the same unit near its rated output. Schneider does not publish runtime figures against the cartridge itself, only against the UPS, so if you need a runtime target for a specific rack load, send us the load in watts and the UPS model and we will size it properly rather than quote a number that will not hold.
Installation. The cartridge is supplied fully assembled with its connectors already fitted, so replacement is a slide-out, slide-in operation rather than a wiring job. Schneider does not publish a statement about whether this particular cartridge may be changed with the UPS energised, so follow the installation guide that ships in the box for the correct sequence on your model, and treat the pack as live: these are high-current lead-acid assemblies and a shorted terminal is a genuine hazard. If you would rather not do it in-house, ask us and we will look at arranging it for you.
Package Contents & RBC Ordering Information
In the Box
All required connectors pre-fitted, installation guide, battery recycling guide, metallic battery tray or enclosure, reusable packaging.
APC Smart-UPS SMT and SMC Replacement Cartridges Stocked by SourceIT
| RBC6 | Smart-UPS C 1500VA tower (SMC1500IC) 11 Ah · 7.68 kg net |
| RBC7 | Smart-UPS 1500VA tower (SMT1500IC) 24 V 17 Ah · 11.68 kg net |
| RBC43 | Smart-UPS 2200/3000VA 2U rack (SMT2200RMI2UC, SMT3000RMI2UC) 48 V 10 Ah · 19.09 kg net |
| RBC48 | Smart-UPS 750VA tower (SMT750IC) 24 V 7 Ah · 5.00 kg net |
| RBC55 | Smart-UPS 2200/3000VA tower (SMT2200IC, SMT3000IC) 12 V 17 Ah modules · 24.27 kg net |
| APCRBC123 | Smart-UPS 750VA 2U rack (SMT750RMI2UC) 24 V 7 Ah · 5.21 kg net |
| APCRBC124 | Smart-UPS C 1000VA 2U rack (SMC1000I-2UC) 24 V 9 Ah · 5.60 kg net |
| APCRBC132 | Smart-UPS 1000VA 2U rack, standard build (SMT1000RMI2U) 7.0 Ah · 10.00 kg net |
| APCRBC133 (this listing) | Smart-UPS 1500VA 2U rack, standard build (SMT1500RMI2U) 9 Ah · 11.96 kg net |
| APCRBC142 | Smart-UPS C 1000VA tower (SMC1000IC) 24 V 9 Ah · 6.01 kg net |
| APCRBC157 | Smart-UPS C 1500VA 2U rack and SMT1000RMI2UC SmartConnect 7.0 Ah · 10.00 kg net |
| APCRBC159 | Smart-UPS 1500VA 2U rack, SmartConnect (SMT1500RMI2UC) 9 Ah · 11.96 kg net |
Matching UPS Models
If you are replacing the UPS rather than the battery, or adding a second unit, these are the models this cartridge is specified for:
| SMT1500RMI2U | APC Smart-UPS 1500VA Rackmount 2U 230V (standard build) |
Ordering notes. Quote the part number APCRBC133 on your purchase order — the cartridge number, not the UPS model, is what determines what ships. This cartridge is a lead-acid assembly and travels as such: check the net weight in the specifications above before arranging a courier, because several cartridges in this range are considerably heavier than they look. We can supply the cartridge on its own, or alongside a network management card, rack PDU or a replacement UPS on a single GST invoice.
Datasheet & Downloads
- Schneider Electric product page for APCRBC133 — official product identity, environmental data and document library
- Schneider FAQ000236099 — correct RBC for SMT 1kVA and 1.5kVA RM standard and SmartConnect models
- APC Back-UPS / Smart-UPS APCRBC123/124/132/133/144/165/166 Installation Guide (v4)
Schneider Electric serves its PDF datasheets from a download host that redirects and does not reliably return the document you asked for, so we do not publish direct PDF links here — a link that hands you another model's datasheet is worse than no link at all. If you need the signed product data sheet, the installation guide or a written confirmation of fitment for your unit, email us the UPS model number and we will send the current document across.
Frequently Asked Questions — APC Replacement Battery Cartridge #133 (APCRBC133)
Which APC UPS models does the APCRBC133 fit?
Schneider specifies it for the SMT1500RMI2U. This is confirmed from Schneider FAQ000236099, which assigns APCRBC133 to the SMT1500RM2U and SMT1500RMI2U standard-build rack models. Selection follows the UPS part number rather than its VA rating, because tower and rack builds of the same capacity take different cartridges. If your model is not named here, send us the part number from the rear label and we will confirm the correct cartridge in writing before you order.
Is the APCRBC133 interchangeable with the APCRBC159?
No. The two cartridges are the same size and the same weight, which is exactly why they get confused, but Schneider states plainly that they are not interchangeable and that the wrong cartridge cannot be properly secured with the battery retention screws. The APCRBC159 is for the SMT1500RMI2UC. One further trap: on units running older firmware the UPS display could name the wrong cartridge, and Schneider documentation published in 2019 gave different part numbers from the current documentation. Trust the part number on the unit, or ask us.
Why doesn't this page state a nominal voltage for the cartridge?
Because Schneider does not publish one for this part, and we will not invent it. Schneider's marketing name carries a 24 V 9 Ah figure, but a cartridge weighing 11.96 kg in a 216 x 343 mm tray holds more blocks than that figure describes. Publishing that block figure as though it were the cartridge voltage is a common error on other listings, and it makes the pack look far smaller than it is. Order by UPS model number and the voltage question does not arise; if you need it confirmed for a technical submission, ask us and we will get it in writing from the distributor.
Can I fit the cartridge myself, and can it be done without shutting the UPS down?
The cartridge ships fully assembled with its connectors already fitted, so mechanically it is a slide-out, slide-in job that needs no wiring and, on most models, no tools. Whether it can be changed with the UPS still running depends on the model, and Schneider does not publish that statement for this cartridge, so follow the installation guide in the box for the correct sequence rather than assuming either way. Treat the pack as live throughout — it is a high-current lead-acid assembly. If the unit is protecting something you would rather not gamble on, ask us about arranging the replacement.
How long should the cartridge last?
Schneider does not publish an expected service life figure for this particular part number, so we do not quote one. What we can say is what drives it: sealed lead-acid cells age markedly faster when they run warm, so in Singapore the temperature of the cabinet matters more than the calendar. A unit in an air-conditioned rack lasts considerably longer than one in a hot riser. Ask us and we will tell you what we actually see in the field on this model.
What do I do with the old cartridge?
Do not put it in general waste. A UPS cartridge is a sealed lead-acid assembly and is regulated waste in Singapore. Schneider supplies a battery recycling guide with the cartridge, and SourceIT can arrange collection of the exhausted pack for proper recycling when the replacement is delivered — tell us when you order so it is scheduled with the delivery.
Is this a genuine APC part, and what does the warranty cover?
Yes. Every APC Replacement Battery Cartridge #133 (APCRBC133) sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the APCRBC133 with a 2-year manufacturer warranty, stated as 2 years repair or replace. Schneider publishes this term worldwide with no regional variation, so the Singapore figure is the same 2 years quoted elsewhere — unlike some APC UPS families, where the European figure is higher and does not apply to a Singapore supply.