TP-Link Omada JetStream 24-Port Gigabit L2+ Managed Switch with 4 10GE SFP+ Slots and UPS Power Supply
PRODUCT DESCRIPTION
TP-Link JetStream 24-Port Gigabit L2+ Managed Switch with 4 10GE SFP+ Slots and UPS Power Supply (TL-SG3428X-UPS) - 5 Years Local Warranty
The TL-SG3428X-UPS is a 24-port Gigabit L2+ managed switch that accepts a 12 V lead-acid battery alongside its mains supply, so the network segment it serves keeps running through a power cut without a separate rack UPS. Four 10G SFP+ uplinks, a fanless 128 Gbps fabric and a shallow 180 mm chassis complete the package.
Built-In UPS Function on a 12 V Lead-Acid Battery
The switch runs from 100-240 V AC and from a 12 V lead-acid battery, charging the battery while mains power is present and drawing from it when mains fails. The battery is not included, so it is specified and sourced to suit the runtime you need. Consumption is low enough to make that practical: 31.9 W on AC while charging, 24.0 W on AC without a battery, and 20.0 W running on battery alone.
Fanless and Shallow — Built for Rooms Without a Comms Cupboard
There are no fans, so the switch is silent and has no moving part to fail, and the chassis is only 180 mm deep against the 330 mm of a typical PoE switch. Combined with the battery input, that suits the places a rack UPS will not go: a reception counter, a shop back office, a clinic, a small branch or a wall-mounted cabinet where the switch simply has to keep working.
Four 10G SFP+ Uplinks and a 128 Gbps Fabric
Four 10 Gbps SFP+ slots carry up to 40 Gbps of backhaul, aggregable into one trunk or split across two upstream switches for a redundant path, and available over fibre for distance. The 128 Gbps switching capacity covers all 28 ports at full duplex and a 95.23 Mpps forwarding rate holds line rate at minimum frame sizes. A 12 Mbit packet buffer, 9 KB jumbo frames and a 16 K MAC address table handle busy, heavily segmented traffic.
L3 Routing With 128 Interfaces and DHCP Services
The switch carries 128 IPv4/IPv6 interfaces, 48 static routes and 128 static ARP entries, with Proxy ARP, Gratuitous ARP, a DHCP Server, DHCP Relay for interfaces and VLANs, and DHCP L2 Relay. A branch site can therefore address and route its own VLANs locally — which matters particularly here, since on battery power the upstream link may well be the thing that is down.
Resilient Layer 2 and a Full Security Stack
Link Aggregation supports static and 802.3ad LACP up to 8 groups of 8 ports; Spanning Tree covers STP, RSTP and MSTP; loopback detection runs port-based or VLAN-based. Security spans IP-MAC-Port and IPv6-MAC-Port Binding at 512 entries each, DHCP and DHCPv6 Snooping, ARP Inspection, ND Detection, DoS Defend, Port Security to 64 MACs per port, Storm Control, Port Isolation and 802.1X with RADIUS, MAB and Guest VLAN. ACLs cover time-based, MAC, IP, combined, packet-content and IPv6 rules.
Managed Centrally Through Omada SDN
Adopted into an Omada Controller, the switch is configured and monitored alongside your gateways and access points, with automatic device discovery, batch configuration, batch firmware upgrading, intelligent network monitoring, abnormal event warnings, unified configuration and reboot scheduling. SNMP v1/v2c/v3 with trap and inform, RMON groups 1, 2, 3 and 9, LLDP/LLDP-MED, CPU monitoring, cable diagnostics and system logging cover integration with existing NMS tooling.
Ideal For
Singapore branch offices, retail outlets, clinics and remote sites that need the network to survive a mains interruption without installing a rack UPS. Supplied by SourceIT with local Singapore warranty, GST invoice and project pricing on request.
TL-SG3428X-UPS Datasheet — Technical Specifications
General
| Model | TL-SG3428X-UPS |
| Official Product Name | JetStream 24-Port Gigabit L2+ Managed Switch with 4 10GE SFP+ Slots and UPS Power Supply |
| Brand | TP-Link Omada / JetStream |
| Warranty | 5 Years Local Warranty (Singapore) |
Hardware
| Interface | 24× 10/100/1000 Mbps RJ45 Ports, 4× 10G SFP+ Slots, 1× RJ45 Console Port, 1× Micro-USB Console Port |
| Power Supply | 100-240 V AC ~ 50/60 Hz and 12 V lead-acid battery (battery not included) |
| Switching Capacity | 128 Gbps |
| Packet Forwarding Rate | 95.23 Mpps |
| MAC Address Table | 16 K |
| Packet Buffer Memory | 12 Mbit |
| Jumbo Frame | 9 KB |
| Dimensions (W x D x H) | 17.3 × 7.1 × 1.7 in (440 × 180 × 44 mm) |
| Fan Quantity | Fanless |
| Mounting | Rack Mountable |
| Max Power Consumption | 31.9 W (AC with battery charging); 24.0 W (AC without battery); 20.0 W (battery powered) |
| Max Heat Dissipation | 108.84 BTU/hr (AC with charging); 81.88 BTU/hr (AC without); 68.24 BTU/hr (battery) |
| Operating Temperature | 0 °C to 45 °C (32 °F to 113 °F) |
| Storage Temperature | -40 °C to 70 °C (-40 °F to 158 °F) |
| Operating Humidity | 10% to 90% RH, non-condensing |
| Storage Humidity | 5% to 90% RH, non-condensing |
| Certification | CE, FCC, RoHS |
Software
| L3 Features | 128 IPv4/IPv6 Interfaces; 48 Static Routes; Static ARP (128 entries); Proxy ARP; Gratuitous ARP; DHCP Server; DHCP Relay (Interface and VLAN); DHCP L2 Relay |
| L2 and L2+ Features | Link Aggregation — static and 802.3ad LACP, up to 8 groups × 8 ports; Spanning Tree — 802.1d STP, 802.1w RSTP, 802.1s MSTP; Loopback Detection (port and VLAN-based); 802.3x Flow Control and HOL Blocking Prevention; Mirroring — Port, CPU, One-to-One, Many-to-One (Tx/Rx/Both) |
| VLAN | Max 4K VLAN Groups; 802.1Q Tagged VLAN; MAC VLAN (30 entries); Protocol VLAN (16 templates, 16 protocol VLANs); Private VLAN; GVRP; Port-Based and Selective QinQ; Voice VLAN |
| L2 Multicast | IGMP Snooping v1/v2/v3 with Fast Leave, Querier and Authentication; MLD Snooping v1/v2 with Querier and Static Group Config; MVR; Multicast Filtering (256 profiles, 16 entries per profile) |
| QoS | 8 priority queues; 802.1p CoS/DSCP priority; Queue scheduling SP, WRR, SP+WRR; Port/flow-based bandwidth control; Mirror, redirect, rate limit and QoS remark actions |
| Access Control List | Time-based ACL; MAC ACL; IP ACL; Combined ACL; Packet Content ACL; IPv6 ACL; Policies — Mirroring, Redirect, Rate Limit, QoS Remark; applied per Port or VLAN |
| Security | IP-MAC-Port Binding (512 entries) with DHCP Snooping and ARP Inspection; IPv6-MAC-Port Binding (512 entries) with DHCPv6 Snooping and ND Detection; DoS Defend; Port Security (up to 64 MAC per port); Broadcast/Multicast/Unicast Storm Control; 802.1X port-based and MAC-based with RADIUS, MAB and Guest VLAN; AAA and TACACS+; Port Isolation; HTTPS/SSL/TLS; SSH v1/v2; IP/Port/MAC-based access control |
| IPv6 | Dual IPv4/IPv6 stack; MLD Snooping; IPv6 ACL; DHCPv6 Snooping; Static IPv6 Routing; ND; Path MTU Discovery; ICMPv6; TCPv6/UDPv6; DHCPv6; Ping6; Tracert6; Telnet; IPv6 SNMP/SSH/SSL/HTTP/HTTPS/TFTP |
| Advanced Features | Automatic Device Discovery; Batch Configuration; Batch Firmware Upgrading; Intelligent Network Monitoring; Abnormal Event Warnings; Unified Configuration; Reboot Schedule |
| Management | Web-based GUI; CLI via console, Telnet or SSH; SNMP v1/v2c/v3 with Trap/Inform; RMON groups 1,2,3,9; SDM Template; DHCP/BOOTP Client; 802.1ab LLDP/LLDP-MED; Dual Image and Dual Configuration; CPU Monitoring; Cable Diagnostics; EEE; Password Recovery; SNTP; System Log |
| MIBs | RFC1213 (MIB II); RFC2233 (Interface); RFC1643 (Ethernet); RFC1493 (Bridge); RFC2674 (P/Q-Bridge); RFC2819/RFC2021 (RMON); RFC2620/RFC2618 (RADIUS); RFC2925 (Remote Ping/Traceroute); TP-Link private MIB |
Compatibility & Software Support
The TL-SG3428X-UPS is part of the Omada ecosystem: gateways, switches and access points are managed together from one controller, under one set of policies, with one view of the network. Cloud and app features listed below require the device to be adopted into an Omada Controller.
| Omada SDN Controller | Supported — adopt and manage centrally from the Omada Software Controller, Hardware Controller or Cloud-Based Controller |
| Battery | 12 V lead-acid battery, supplied separately |
| PoE | Not supported on this model — the switch does not power connected devices |
| Standalone Mode | Supported — web GUI, or CLI via console, Telnet or SSH |
Package Contents & Ordering Information
Package Contents
| In the Box | TL-SG3428X-UPS Switch, Power Cord, Quick Installation Guide, Rackmount Kit, Rubber Feet |
| Not Included | 12 V lead-acid battery |
Ordering Information
| Model | TL-SG3428X-UPS |
| Optics | 10G SFP+ modules and DAC cables are ordered separately — ask SourceIT to quote them with the switch |
Datasheet & Downloads
Frequently Asked Questions — TL-SG3428X-UPS
Is a battery included?
No. The switch accepts a 12 V lead-acid battery, which is supplied separately so you can size it for the runtime you need. SourceIT can advise on a suitable battery when quoting.
How long will it run on battery?
That depends entirely on the battery's capacity. The switch draws 20.0 W when running on battery power, so runtime is a function of the amp-hour rating you choose.
Does it supply PoE?
No. This model has no PoE on any port. If the access points or cameras also need to survive a power cut, they require their own power arrangement.
Does it need an Omada Controller?
No. It runs standalone through its own web GUI or CLI. Adopting it into an Omada Controller is what unlocks central configuration, monitoring, firmware management and cloud/app access across every Omada device on site — at no licence cost.
What warranty does SourceIT provide?
Five years local Singapore warranty. Every TL-SG3428X-UPS sold by SourceIT comes with a GST invoice.