Eaton Rack PDU G4 Metered Input 0U Vertical PDU, Three-phase 32A IEC 60309 Input, 22 kW, 24x C13 + 18x C39, Network
PRODUCT DESCRIPTION
Eaton Rack PDU G4 Metered Input 0U Three-phase 32A 22 kW Rack PDU (EVMIF332X, 9001-22351) - 2 Years Local Warranty
See What Your Rack Is Drawing — With Billing-Grade Accuracy
The Eaton Rack PDU G4 EVMIF332X is a Metered Input 0U (vertical) rack PDU. It takes a three-phase 32A feed through an IEC 60309 32A three-phase plug on a 3 m cord, distributes up to 22 kW to 42 outlets (24 x IEC C13 + 18 x IEC C39), and measures the whole PDU's input with 1% IEC Class 1 billing-grade accuracy, as published by Eaton.
For a Singapore server room, enterprise comms room or colocation rack, that means you can check real load against the feed rating before adding equipment, spot rising consumption early, and report energy per rack with numbers you can bill against.
Gigabit Networking, Modern Protocols and Cybersecurity
Eaton fits the Rack PDU G4 with a gigabit network card with 2 x Gb ports, supporting RestAPI, Modbus TCP, SNMP, LDAP and HTTPS. Up to 32 PDUs can be cascaded, and the network control module is hot-swappable. Eaton also lists power sharing between two network modules. An optional temperature/humidity sensor can be added.
Eaton lists compliance with the UL 2900-1 and IEC 62443-4-2 cybersecurity standards — useful where IT security teams audit every networked device in the data centre.
C39 Outlets That Take Either C14 or C20 Plugs
Eaton describes the C39 outlet as versatile: it accepts either a C14 or a C20 power cord plug. With 24 x IEC C13 + 18 x IEC C39, you can mix standard servers and switches with higher-power C20-corded equipment without re-planning the rack. Eaton also specifies high-retention outlets to help keep cords seated.
Rated for Hot Aisles: 0–60 °C Operation
Eaton rates the Rack PDU G4 for operation from 0 °C to 60 °C, which gives margin at the back of a densely packed rack where exhaust air collects. The chassis is aluminium, finished in black.
Supplied Locally with GST Invoice and 2-Year Warranty
SourceIT supplies the Eaton Rack PDU G4 range in Singapore with a full GST invoice and local warranty support. Eaton's Singapore price list gives a 2-year warranty for ePDUs.
Need help choosing an input plug or outlet mix? Email sales@sourceit.com.sg with your rack layout and supply type.
Eaton EVMIF332X Datasheet — Technical Specifications
General
| Product Name | Eaton Rack PDU G4 |
| Catalogue Number | EVMIF332X |
| Part Number (SKU) | 9001-22351 |
| Model Code | PDU G4 MI 0U 309 32A 3P 24xC13,18xC39 |
| Range | Eaton Rack PDU G4 |
| Type | Metered Input Rack PDU |
| Form Factor | 0U (vertical) |
| Outlet Control | No |
| Local Warranty (Singapore) | 2 years (Eaton Singapore price list), supplied by SourceIT with a GST invoice |
Power
| Phase | Three-phase |
| Input Connection | IEC 60309 32A three-phase |
| Amperage Rating | 32 A |
| Input Voltage | 240/415 V |
| Frequency | 50/60 Hz |
| Maximum Power | 22 kW |
| Circuit Breakers | 6 x single-pole |
| Cord Length | 3 m |
Outlets
| Total Outlets | 42 |
| Outlet Types | 24 x IEC C13 + 18 x IEC C39 |
| C39 Outlets | Accept C14 or C20 power cord plugs |
| Outlet Retention | High-retention outlets |
Metering & Network
| Metering | Input (whole-PDU) metering |
| Measurement Accuracy | 1% IEC Class 1 (billing grade) |
| Switchable Outlets | No |
| Network | Gigabit network card, 2 x Gb ports |
| Protocols | RestAPI, Modbus TCP, SNMP, LDAP, HTTPS |
| Serial Interface | Yes |
| Network Module | Hot-swappable |
| Power Sharing | Between two network modules |
| Cascading | Up to 32 PDUs |
| Mass Configuration | Yes |
| Sensors | Optional temperature/humidity sensor |
| Cybersecurity | UL 2900-1 and IEC 62443-4-2 |
Physical & Environmental
| Dimensions (L x W x H) | 1730 x 52 x 53 mm |
| Weight | 5.5 kg |
| Material / Colour | Aluminium / Black |
| Operating Temperature | 0–60 °C |
| Overvoltage Category | 2 |
| Certifications | IEC 62368-1, EN IEC 63000, CISPR 35/EN 55035, CE, EAC, UKCA, Cm, Ukr, IEC/EN 61000-6-2, IEC/EN 61000-6-4, IEC 61000-3-11, IEC 61000-3-12 |
Compatibility & Software Support
What It Is Suited To
The EVMIF332X suits IT equipment with IEC C14 or C20 power cords — rack servers, storage arrays, switches, routers and firewalls. Keep the total connected load within 22 kW and within the rating of the circuit that feeds the PDU, and balance loads across the phases.
Monitoring and Integration
Manage the PDU from a web browser over HTTPS, or bring it into an existing NMS, BMS or DCIM platform over SNMP, Modbus TCP or the RestAPI. LDAP support allows central user authentication. Metering is for the whole PDU; for per-outlet control, ask us about Rack PDU G4 Switched and Managed models.
Input Plug and Supply
The input is an IEC 60309 32A three-phase plug on a 3 m cord. Your rack feed needs the matching IEC 60309 32A three-phase socket, installed by a licensed electrician; a standard BS 1363 wall socket cannot feed this PDU.
Package Contents & Rack PDU G4 Metered Input Ordering Information
In the Box
Eaton lists the package contents as: the Rack PDU, rack mounting accessories, a quick start guide and safety instructions.
Eaton Rack PDU G4 Metered Input Range — Ordering Information
| EVMIFC20A | 0U, 1-phase, C20, 3.7 kW | 12 x C13 + 12 x C39 | 9001-22340 |
| EVMIF116A | 0U, 1-phase, IEC 60309 16A, 3.7 kW | 12 x C13 + 12 x C39 | 9001-22336 |
| EVMIF132A | 0U, 1-phase, IEC 60309 32A, 7.4 kW | 12 x C13 + 12 x C39 | 9001-22324 |
| EVMIF132X | 0U, 1-phase, IEC 60309 32A, 7.4 kW | 24 x C13 + 18 x C39 | 9001-22348 |
| EVMIF316A | 0U, 3-phase, IEC 60309 16A, 11 kW | 12 x C13 + 12 x C39 | 9001-22331 |
| EVMIF316X | 0U, 3-phase, IEC 60309 16A | Ask us | 9001-22345 |
| EVMIF332A | 0U, 3-phase, IEC 60309 32A | Ask us | 9001-22328 |
| EVMIF332X (this listing) | 0U, 3-phase, IEC 60309 32A, 22 kW | 24 x C13 + 18 x C39 | 9001-22351 |
Rack PDU G4 Basic, Switched and Managed models are also available on request.
Datasheet & Downloads
| Eaton specifications | Eaton EVMIF332X Specifications — Eaton Singapore |
| Eaton brochure | Eaton Rack PDU G4 Brochure BR155022 (PDF) |
| Technical drawing | Eaton EVMIF332X Outline Drawing (PDF) |
| Quick guide | Eaton Rack PDU G4 Quick Guide (PDF) |
| Installation guide | Eaton Rack PDU G4 Installation and Setup Guide (PDF) |
Need a PDF sent directly? Email sales@sourceit.com.sg quoting EVMIF332X.
Frequently Asked Questions — Eaton EVMIF332X
What does the EVMIF332X measure?
Whole-PDU input, with 1% IEC Class 1 billing-grade accuracy per Eaton. It does not switch individual outlets — ask us about Rack PDU G4 Switched and Managed models for that.
How do I access it remotely?
Over the gigabit network card (2 x Gb ports) using a web browser (HTTPS), SNMP, Modbus TCP or RestAPI. LDAP is supported for central authentication, and up to 32 PDUs can be cascaded.
Can I add temperature or humidity sensing?
Yes — Eaton lists an optional temperature/humidity sensor, sold separately. Ask us for a quote.
How many devices can I connect?
42 outlets: 24 x IEC C13 + 18 x IEC C39. C13 outlets take the common C14 cord; Eaton's C39 outlets take either a C14 or a C20 plug. Keep the total load within 22 kW.
What supply do I need?
A three-phase 32A feed with a matching IEC 60309 32A three-phase socket (240/415 V), installed by a licensed electrician.
How hot can the rack get?
Eaton rates the Rack PDU G4 for 0–60 °C operation.
What warranty do I get?
2 years per Eaton's Singapore price list, supplied by SourceIT with local Singapore support and a GST invoice.