Rising component costs may adjust prices on selected items without prior notice. Supply constraints may add shipping time — we’ll notify you if affected. OEM costs and supply tightening — contact us to secure stock and pricing. For projects or bulk orders, choose “Request for Quotation” on any item.
Call our specialists(65) 6978 3502 Email our sales teamsales@sourceit.com.sg
Eaton FlexPDU G2 range (family image from Eaton; FLXTMI116C2 not shown individually)

Eaton FlexPDU G2 Metered Input 0U Vertical Rack PDU, Single-phase 16A IEC 60309 Input, 20x C13 + 4x C19, Network

SKU: P-FLXTMI116C2

  • S$387.50
    Unit price per 
Shipping calculated at checkout.

PRODUCT DESCRIPTION

Eaton FlexPDU G2 Metered Input 0U Single-phase 16A Rack PDU (FLXTMI116C2, P-FLXTMI116C2) - 2 Years Local Warranty

Know Exactly What Your Rack Is Drawing

The Eaton FlexPDU G2 FLXTMI116C2 is a Metered Input rack PDU from Eaton's second-generation FlexPDU range. It takes a single-phase 16A IEC 60309 feed and distributes up to 3.7 kW to 24 IEC outlets (20 x IEC C13 + 4 x IEC C19), while measuring the whole PDU's current, voltage, power, energy consumption and power factor with ±1% accuracy, as published by Eaton.

For a Singapore server room, comms cabinet or colocation rack, that means you can see real load against the feed rating before adding equipment, spot creeping consumption, and report energy use per rack instead of guessing.

Full Network Management, Built for Security

Eaton's FlexPDU G2 Metered Input models include a network management module with a 10/100 Mbps Ethernet port, full management through a web browser or SNMP, and support for HTTPS, SSH v2, SNMP, SMTP, DHCP, RADIUS, NTP and TELNET over IPv4 and IPv6. Firmware can be upgraded remotely, up to 8 external sensors can be connected, and the range supports cascade (daisy-chain) connection.

Eaton states the FlexPDU G2 network models meet the UL 2900-1 and IEC 62443-4-1 cybersecurity standards, and on 0U models the network management module is hot-swappable, so it can be replaced without interrupting power to the connected equipment.

Built for Safety in the Rack

Eaton equips every outlet with an anti-ejection mechanism so power cords are held firmly in place, uses pure copper for the main circuit conductors, and provides additional enclosure grounding points.

Supplied Locally with GST Invoice and 2-Year Warranty

SourceIT supplies the FlexPDU G2 range in Singapore with a full GST invoice and local warranty support. Eaton's FlexPDU G2 brochure and Eaton's Singapore price list both give a 2-year warranty.

Need help choosing an input plug or outlet mix? Email sales@sourceit.com.sg with your rack layout and supply type.

Eaton FLXTMI116C2 Datasheet — Technical Specifications

General

Product Name Eaton FlexPDU G2
Catalogue Number FLXTMI116C2
Part Number (SKU) P-FLXTMI116C2
Range Eaton FlexPDU 2nd Generation (G2)
Type Metered Input rack PDU (whole-PDU metering, network management)
Form Factor 0U vertical (zero-U, mounts in the rack's side channel)
Manufacturer Warranty 2 years (Eaton FlexPDU G2 brochure)
Local Warranty (Singapore) 2 years, supplied by SourceIT with a GST invoice

Power

Phase Single-phase
Input Connection IEC 60309 plug
Input Rating 16 A
Nominal Voltage 230V (Eaton Singapore price list)
Nominal Power 3.7 kW
Circuit Breakers None (Eaton lists no breaker for this model)
Input Cord Length 3.0 m (Eaton brochure)

Outlets

Total Outlets 24
Outlet Types 20 x IEC C13 + 4 x IEC C19
Outlet Retention Anti-ejection mechanism on all outlets

Metering & Network

Metering Full PDU measurements: current, voltage, power, energy consumption, power factor
Measurement Accuracy ±1%
Per-outlet Metering / Switching No (available on FlexPDU G2 Managed / Switched models)
Network Interface 10/100 Mbps Ethernet; web and SNMP management
Protocols HTTPS, SSH v2, SNMP, SMTP, DHCP, RADIUS, NTP, TELNET; IPv4 and IPv6
Firmware Remote firmware upgrade
External Sensors Up to 8
Cascade (Daisy-chain) Supported
Network Module Hot-swappable (0U models)
Cybersecurity Meets UL 2900-1 and IEC 62443-4-1

Physical & Environmental

Main Conductors Pure copper
Maximum Operating Temperature 50 °C
Operating Altitude 0–3,000 m
Certifications CE; EN 62368-1:2014
Compatibility & Software Support

What It Is Suited To

The FLXTMI116C2 suits IT equipment with IEC C14 or C20 power cords — rack servers, storage arrays, switches, routers and firewalls. Keep the total connected load within 3.7 kW and within the rating of the supply that feeds the PDU.

Monitoring and Software

Manage the PDU from any web browser, or bring it into an existing monitoring or DCIM platform over SNMP (Eaton lists SNMP among the supported protocols, along with SMTP for e-mail alerts and RADIUS for central authentication). Metering is for the whole PDU; for per-outlet measurement or remote outlet switching, choose a FlexPDU G2 Managed or Switched model.

Input Plug and Supply

The input is an IEC 60309 16A single-phase industrial plug. Your rack feed needs the matching IEC 60309 socket, installed by a licensed electrician; a standard BS 1363 wall socket cannot feed this PDU.

Package Contents & FlexPDU G2 Metered Input Ordering Information

In the Box

Eaton FlexPDU G2 Metered Input PDU with user documentation. Eaton's brochure does not list the carton contents or mounting hardware, so confirm brackets and accessories with us before ordering if they matter to your installation.

Eaton FlexPDU G2 Metered Input Range — Ordering Information

FLXTMIC14C1 1U, 1-phase, IEC C14 10A, 2.3 kW 8 x C13 P-FLXTMIC14C1
FLXTMIC20C1 1U, 1-phase, IEC C20 16A, 3.7 kW 8 x C13 P-FLXTMIC20C1
FLXTMIC20C2 0U, 1-phase, IEC C20 16A, 3.7 kW 20 x C13 + 4 x C19 P-FLXTMIC20C2
FLXTMI116C2 (this listing) 0U, 1-phase, IEC 60309 16A, 3.7 kW 20 x C13 + 4 x C19 P-FLXTMI116C2
FLXTMI132C2 0U, 1-phase, IEC 60309 32A, 7.4 kW 20 x C13 + 4 x C19 P-FLXTMI132C2
FLXTMI163C5 0U, 1-phase, IEC 60309 63A, 14.5 kW 36 x C13 + 6 x C19 P-FLXTMI163C5
FLXTMI316C3 0U, 3-phase, IEC 60309 16A, 11.0 kW 18 x C13 + 6 x C19 P-FLXTMI316C3
FLXTMI316C5 0U, 3-phase, IEC 60309 16A, 11.0 kW 36 x C13 + 6 x C19 P-FLXTMI316C5
FLXTMI332C3 0U, 3-phase, IEC 60309 32A, 22.0 kW 18 x C13 + 6 x C19 P-FLXTMI332C3
FLXTMI332C4 0U, 3-phase, IEC 60309 32A, 22.0 kW 30 x C13 + 6 x C19 P-FLXTMI332C4
FLXTMI332C5 0U, 3-phase, IEC 60309 32A, 22.0 kW 36 x C13 + 6 x C19 P-FLXTMI332C5
FLXTMI363C5 0U, 3-phase, IEC 60309 63A, 43.5 kW 36 x C13 + 6 x C19 P-FLXTMI363C5

Basic, Switched and Managed FlexPDU G2 models are also available on request.

Datasheet & Downloads
Eaton brochure Eaton FlexPDU G2 Brochure — East Asia (PDF)
Eaton datasheet Eaton FlexPDU G2 Datasheet BR155060EN (PDF)
Eaton product page Eaton FlexPDU G2 — Eaton Singapore

Need a PDF sent directly? Email sales@sourceit.com.sg quoting FLXTMI116C2.

Frequently Asked Questions — Eaton FLXTMI116C2

What does the FLXTMI116C2 measure?

Whole-PDU current, voltage, power, energy consumption and power factor, with ±1% accuracy per Eaton. It does not meter or switch individual outlets — that needs a FlexPDU G2 Managed (per-outlet metering) or Switched (outlet on/off) model.

How do I access it remotely?

Through its 10/100 Mbps Ethernet port, using a web browser or SNMP. Supported protocols include HTTPS, SSH v2, SNMP, SMTP, DHCP, RADIUS, NTP and TELNET, over IPv4 and IPv6.

Can I add temperature or humidity sensors?

Yes — Eaton lists an external sensor capacity of 8 for FlexPDU G2 network models. Sensors are sold separately; ask us for a quote.

How many devices can I connect?

24 outlets: 20 x IEC C13 + 4 x IEC C19. C13 outlets take the common IEC C14 server/switch cord; C19 outlets take C20 cords used by higher-power equipment. The total load must stay within 3.7 kW.

What supply do I need?

A single-phase 16A feed matching the IEC 60309 input. An IEC 60309 socket must be installed by a licensed electrician.

What warranty do I get?

2 years from Eaton, supplied by SourceIT with local Singapore support and a GST invoice.


We Also Recommend