{"product_id":"tp-link-omada-pro-48-port-2-5g-stackable-l3-managed-poe-switch-with-6-25g-slots","title":"TP-Link Omada Pro 48-Port 2.5G Stackable L3 Managed PoE++ Switch with 6 25G Slots","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eTP-Link Omada Pro 48-Port 2.5G Stackable L3 Managed PoE++ Switch with 6 25G Slots (S6500-48MPP6Y) - 5 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe S6500-48MPP6Y is a 48-port 2.5G PoE++ access switch built for multi-gigabit access points and high-power edge devices: every RJ45 port runs at up to 2.5 Gbps and delivers up to 60 W of 802.3bt power, with six 1\/10\/25G SFP28 uplinks and full Layer 3 routing. Its PoE budget depends on the power supply modules fitted — 701 W as shipped, up to 1,484 W with two PSM900-AC.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e48× 2.5G PoE++ Ports for Multi-Gigabit Access Points\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAll 48 RJ45 ports are 2.5G and IEEE 802.3bt\/at\/af compliant, delivering up to 60 W per port. That suits multi-gigabit Wi-Fi access points and other high-draw devices that a 30 W PoE+ port cannot fully power, while the 2.5G link keeps a modern AP from being bottlenecked by a Gigabit uplink.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePoE Budget Scales With the Power Supplies You Fit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTP-Link's datasheet gives the PoE budget per power-supply combination: 701 W with the single PSM900-AC shipped by default, 328 W with one PSM500-AC, 752 W with two PSM500-AC, 1,118 W with one PSM500-AC plus one PSM900-AC, and 1,484 W with two PSM900-AC. The second module is a separate purchase, so size the order to the total PoE load — a fully loaded switch drawing 1,484 W needs two PSM900-AC.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSix 25G Uplinks and 12-Unit Stacking\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSix 1\/10\/25G SFP28 slots connect to the aggregation layer or stack the switch; up to 12 units stack in standalone mode with up to 300 Gbps of stack bandwidth across six stacking ports. Stacking runs only over 25G DAC or 25G SFP28 modules. Switching capacity is 540 Gbps per unit and forwarding 401.7 Mpps.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLayer 3 at the Edge\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOSPFv2 (16 instances), OSPFv3, BGP, IS-IS with IPv6 and BFD, RIP and RIPng, VRRP v2\/v3, PBR, uRPF and PIM-SM\/DM\/SSM multicast routing let the access stack route locally. Table sizes are 10,240 IPv4 network routes (shared with IPv6), 6,100 host routes and 7,680 dynamic ARP entries, with ECMP across up to 32 next hops.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMACsec and Campus-Grade Access Security\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMACsec (gcm-aes-128, gcm-aes-256) encrypts links at Layer 2, alongside 802.1X with MAB and guest VLAN, RADSEC, TACACS+, dynamic ARP inspection, IPv4\/IPv6 source guard, port security up to 64 MAC addresses per port and Secure Boot. Four hot-swappable fans and two hot-swappable power supply bays keep the switch serviceable in place.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCentralized Management Through Omada Pro\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTP-Link positions the S6500-48MPP6Y for its Omada Pro platform: the switch is managed centrally from the Omada Pro Cloud-Based, Hardware or Software Controller, with the Omada App and cloud access working through that controller. Zero-Touch Provisioning lets a replacement or new unit be pre-configured in the Omada Pro Cloud-Based Controller and pull its configuration on first boot, so a site does not need an engineer on hand with a console cable. Where a controller is not wanted, the switch is fully manageable on its own through the web GUI, CLI (console or telnet) and SNMPv1\/v2c\/v3.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIdeal For\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCampus access layers deploying multi-gigabit Wi-Fi access points, schools, hospitals, hotels and offices powering high-draw PoE devices from one stackable, routed switch. Supplied by SourceIT with local Singapore warranty, GST invoice and project pricing on request.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eS6500-48MPP6Y Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS6500-48MPP6Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Product Name\u003c\/td\u003e\n\u003ctd\u003eOmada Pro 48-Port 2.5G Stackable L3 Managed PoE++ Switch with 6 25G Slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTP-Link Omada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eS6500 Series campus access switch (Omada Pro managed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years Local Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eHardware Features\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003e48× 2.5G PoE++ RJ45 Ports; 6× 1\/10\/25G SFP28 Slots***; 2× USB 2.0 Ports; 1× RJ45 Console Port; 1× USB Type-C Console Port; 1× RJ45 Management Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan Quantity\u003c\/td\u003e\n\u003ctd\u003eFour Field-replaceable and Hot-swappable Fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTwo Field-replaceable and Hot-swappable Power Supply Modules** (100–240 VAC, 50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e17.3 × 18.1 × 1.7 in (440 × 460 × 44 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRackmountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd\u003e142.2 W (110 V\/60 Hz) (With no PD connected); 1,887.4 W (110 V\/60 Hz) (With 1484 W PD connected and powered by 2× PSM900-AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Heat Dissipation\u003c\/td\u003e\n\u003ctd\u003e484.9 BTU\/hr (110 V\/60 Hz) (With no PD connected); 6,436.03 BTU\/hr (110 V\/60 Hz) (With 1484 W PD connected and powered by 2× PSM900-AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePower over Ethernet\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e802.3at\/af\/bt compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE+ Ports\u003c\/td\u003e\n\u003ctd\u003e48 Ports, up to 60 W per port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Power Budget\u003c\/td\u003e\n\u003ctd\u003eup to 1484 W*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Budget by Power Supply (datasheet)\u003c\/td\u003e\n\u003ctd\u003e701 W (with 1*PSM900-AC, by default); 328 W (with 1*PSM500-AC); 752 W (with 2*PSM500-AC); 1118 W (with 1*PSM500-AC and 1*PSM900-AC); 1484 W (with 2*PSM900-AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacket Buffer Memory\u003c\/td\u003e\n\u003ctd\u003e3 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo Frame\u003c\/td\u003e\n\u003ctd\u003e9 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStacking\u003c\/td\u003e\n\u003ctd\u003eStacking Number: 12 (standalone mode); Stacking Port: 25G SFP28 Slot (all uplink ports can be used as stacking ports)****; Stack Bandwidth: Up to 300 Gbps (6 stacking ports)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Capacity\u003c\/td\u003e\n\u003ctd\u003e540 Gbps per Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacket Forwarding Rate\u003c\/td\u003e\n\u003ctd\u003e401.7 Mpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC Address Table\u003c\/td\u003e\n\u003ctd\u003e32 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eLayer 3 Features\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eL3 Interface\u003c\/td\u003e\n\u003ctd\u003e256 (IPv4, IPv6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic Route\u003c\/td\u003e\n\u003ctd\u003e1,024 IPv4, 512 IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Route Table\u003c\/td\u003e\n\u003ctd\u003eMax 6,100 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv4 Network Router Entries\u003c\/td\u003e\n\u003ctd\u003e10,240 (shared with IPv6 Network Router entries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv6 Network Router Entries\u003c\/td\u003e\n\u003ctd\u003e5,120 (shared with IPv4 Network Router entries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECMP\u003c\/td\u003e\n\u003ctd\u003e256 entries, max 32 ECMP Nexthops per Destination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic ARP\u003c\/td\u003e\n\u003ctd\u003e512 static entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic ARP \/ ND\u003c\/td\u003e\n\u003ctd\u003e7,680 dynamic entries \/ 7,680\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDHCP Server\u003c\/td\u003e\n\u003ctd\u003eMax 64 IP pool, Max 8,000 IP entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDHCPv4\/v6 Relay\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVRRP\u003c\/td\u003e\n\u003ctd\u003eVersion v2\/v3, Max 64 instances, Max 32 Virtual IP per instance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOSPFv2\u003c\/td\u003e\n\u003ctd\u003eOSPF Instance: 16; Network Entries: 256 entries; Area Entries for Stub or NSSA: 16 per instance; Area Range Entries: 16 per instance; Virtual-link Entries: 16 per instance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOSPFv3\u003c\/td\u003e\n\u003ctd\u003eArea Entries for Stub or NSSA: 16 per instance; Area Range Entries: 16 per instance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRIPv1\/v2 \/ RIPng\u003c\/td\u003e\n\u003ctd\u003eNetwork Entries: 256; Redistribute Entries: 20 \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS-IS\u003c\/td\u003e\n\u003ctd\u003eIS-IS Interfaces: 128; IS-IS Area Numbers: 3; Max Redistribute Configs: 10; IS-IS IPV6; IS-IS BFD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBGP\u003c\/td\u003e\n\u003ctd\u003eMax 20 redistribute configs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePIM-SM\/PIM-DM\/PIM-SSM\u003c\/td\u003e\n\u003ctd\u003eIP Multicast Route Entries: 1K; PIM Neighbors: 256; Max PIM Interfaces: 128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIGMP\u003c\/td\u003e\n\u003ctd\u003eVersion v1\/v2\/v3, Max 2,048 multicast groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBFD\u003c\/td\u003e\n\u003ctd\u003e16 template numbers, 8 session numbers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePBR \/ uRPF\u003c\/td\u003e\n\u003ctd\u003eYes \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eLayer 2, VLAN \u0026amp; Quality of Service\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eL2 \/ L2+ Features\u003c\/td\u003e\n\u003ctd\u003eLink Aggregation; Spanning Tree Protocol; Port-based and VLAN-based Loopback Detection; 802.3x Flow Control; ERPS; Mirroring; RSPAN; MAC Address Table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulticast\u003c\/td\u003e\n\u003ctd\u003eIGMP Snooping; MLD Snooping; Multicast VLAN Registration (MVR); Max Multicast Table: 4K (IPv4, IPv6); Fast Leave; Static Multicast Groups; Multicast Filtering; IGMP Snooping Authentication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLAN Group\u003c\/td\u003e\n\u003ctd\u003eMax 4K VLAN Group (802.1q VLAN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVLAN Types\u003c\/td\u003e\n\u003ctd\u003e802.1Q Tagged VLAN; Multicast VLAN; Management VLAN; GVRP; Voice VLAN; Private VLAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC VLAN Entries\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVLAN VPN (QinQ)\u003c\/td\u003e\n\u003ctd\u003eMax 256 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol VLAN\u003c\/td\u003e\n\u003ctd\u003eProtocol Template 16, Protocol VLAN 12 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality of Service\u003c\/td\u003e\n\u003ctd\u003e8 Queues of Priority; Port Priority; IEEE 802.1p Priority; DSCP Priority; Queue Min-Bandwidth; Schedule Mode (SP, WRR, SP+WRR); Rate Limit; Storm Control; Voice VLAN; User-Defined OUI; Smoother Performance; QoS remark (802.1P Remark, DSCP Remark); WRED profile: 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eSecurity\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Isolation \/ CPU-Defend\u003c\/td\u003e\n\u003ctd\u003eYes \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP Inspection\u003c\/td\u003e\n\u003ctd\u003eDynamic ARP Inspection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoS Defend \/ DHCP Filter\u003c\/td\u003e\n\u003ctd\u003eYes \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP-MAC-Port Binding\u003c\/td\u003e\n\u003ctd\u003e1,024 Entries; DHCP Snooping; ARP Inspection; IPv4 Source Guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv6-MAC-Port Binding\u003c\/td\u003e\n\u003ctd\u003e1,024 Entries; DHCPv6 Snooping; ND Detection; ND Snooping; IPv6 Source Guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic\/Dynamic Port Security\u003c\/td\u003e\n\u003ctd\u003eUp to 64 MAC addresses per port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroadcast\/Multicast\/Unknown-unicast Storm Control\u003c\/td\u003e\n\u003ctd\u003ekbps\/ratio control mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e802.1X\u003c\/td\u003e\n\u003ctd\u003ePort base authentication; Mac base authentication; VLAN Assignment; MAB; Guest VLAN; RADIUS authentication and accountability support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAAA\u003c\/td\u003e\n\u003ctd\u003eTACACS+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Management\u003c\/td\u003e\n\u003ctd\u003eHTTPS with SSLv3\/TLS 1.2; SSHv2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP\/Port\/MAC-based Access Control\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMACSec\u003c\/td\u003e\n\u003ctd\u003egcm-aes-128, gcm-aes-256\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Boot \/ RADSEC\u003c\/td\u003e\n\u003ctd\u003eYes \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eManagement\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOmada App\u003c\/td\u003e\n\u003ctd\u003eYes, through Omada Pro Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCentralized Management\u003c\/td\u003e\n\u003ctd\u003eOmada Pro Cloud-Based Controller, Omada Pro Hardware Controller, Omada Pro Software Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCloud Access\u003c\/td\u003e\n\u003ctd\u003eYes, through Omada Pro Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-Touch Provisioning\u003c\/td\u003e\n\u003ctd\u003eYes. Requiring the use of Omada Pro Cloud-Based Controller.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Features\u003c\/td\u003e\n\u003ctd\u003eWeb-based GUI; Command Line Interface (CLI) through console port, telnet; SNMPv1\/v2c\/v3 (Trap\/Inform, RMON 1, 2, 3, 9 groups); SDM Template; DHCP\/BOOTP Client; 802.1ab LLDP\/LLDP-MED; DHCP Auto Install; Dual Image, Dual Configuration; CPU Monitoring; Cable Diagnostics; Password Recovery; SNTP; System Log; IEEE 802.3az Energy Efficient Ethernet (EEE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters; -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 °C to 70 °C (-40 °F to 158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e10–90% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Humidity\u003c\/td\u003e\n\u003ctd\u003e5–90% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eTP-Link Footnotes\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e*The total PoE budget varies with the power supply modules.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e**Ships with one PSM900-AC module by default, and another field-replaceable redundant power supply requires a separate purchase.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e‡These functions require the use of the Omada Pro SDN Controller. Zero-Touch Provisioning requires the use of the Omada Pro Cloud-Based Controller.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e△Supports 12 units of physical stacking in standalone mode.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e***No more than two 10G RJ45\/SFP+ modules (SM5310-T) are supported, and they can only be inserted into SFP+ slots 49\u0026amp;53.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e****The 25G SFP28 slots support stacking only through 25G DAC\/25G SFP28 modules rather than 10G DAC\/10G SFP+ modules.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe specification table labels the row \"PoE+ Ports\" while giving up to 60 W per port and 802.3bt compliance, and the product name calls the ports PoE++; both are reproduced as TP-Link publishes them. The PoE budget figures per power-supply combination are from TP-Link's datasheet; the product page states only \"up to 1484 W\".\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Software Support\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eThe S6500-48MPP6Y is an Omada Pro switch. TP-Link lists the Omada Pro controllers — not the standard Omada SDN controller — as its centralized-management platform, so plan the controller with the switch. Its 802.3bt ports also power Omada access points regardless of how the APs themselves are managed.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOmada Pro SDN Controller\u003c\/td\u003e\n\u003ctd\u003eSupported — centralized management through the Omada Pro Cloud-Based Controller, Omada Pro Hardware Controller or Omada Pro Software Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOmada App\u003c\/td\u003e\n\u003ctd\u003eSupported — through an Omada Pro Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCloud Access\u003c\/td\u003e\n\u003ctd\u003eSupported — through an Omada Pro Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-Touch Provisioning\u003c\/td\u003e\n\u003ctd\u003eSupported — requires the Omada Pro Cloud-Based Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandalone Management\u003c\/td\u003e\n\u003ctd\u003eSupported — web-based GUI, CLI (console port, telnet) and SNMPv1\/v2c\/v3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStacking Mode Limit\u003c\/td\u003e\n\u003ctd\u003eUp to 12 units in standalone mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransceivers \u0026amp; Cabling\u003c\/td\u003e\n\u003ctd\u003e1\/10\/25G SFP28 slots (no more than two SM5310-T 10G RJ45\/SFP+ modules, in slots 49 and 53 only); stacking only through 25G DAC\/25G SFP28 modules rather than 10G DAC\/10G SFP+ modules.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eTP-Link's note: these functions require the use of the Omada Pro SDN Controller. Zero-Touch Provisioning requires the use of the Omada Pro Cloud-Based Controller.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat’s in the Box\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eS6500-48MPP6Y Switch, Power Cords, RJ45 Console Cable, Quick Installation Guide, Rackmount Kit, Rubber Feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eOrdering Information\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS6500-48MPP6Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Retail Price (incl. GST)\u003c\/td\u003e\n\u003ctd\u003eS$15,999.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Shipped\u003c\/td\u003e\n\u003ctd\u003e1× PSM900-AC (900 W AC Power Supply Module), installed by default — 701 W PoE budget\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant \/ Additional Power Supply\u003c\/td\u003e\n\u003ctd\u003ePSM900-AC or PSM500-AC — sold separately; two PSM900-AC give the full 1,484 W PoE budget\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eTP-Link's package list reads \"Power Cords\" (plural) although the switch ships with one power supply module by default; reproduced as published.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.omadanetworks.com\/sg\/business-networking\/omada-switch-campus\/s6500-48mpp6y\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Omada S6500-48MPP6Y product page\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/support.omadanetworks.com\/sg\/document\/6124\/\" target=\"_blank\" rel=\"noopener\"\u003eS6500-48MPP6Y datasheet (Omada support, PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.omadanetworks.com\/sg\/support\/download\/s6500-48mpp6y\/\" target=\"_blank\" rel=\"noopener\"\u003eS6500-48MPP6Y firmware, guides \u0026amp; downloads (Omada support)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.omadanetworks.com\/sg\/\" target=\"_blank\" rel=\"noopener\"\u003eOmada Networks Singapore\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — S6500-48MPP6Y\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eDoes the S6500-48MPP6Y need an Omada controller?\u003c\/h4\u003e\n\u003cp\u003eNo. The S6500-48MPP6Y can be run standalone through its web-based GUI or the CLI (console port or telnet). TP-Link lists the Omada Pro Cloud-Based, Hardware and Software Controllers for centralized management; the Omada App and cloud access work through an Omada Pro Controller, and Zero-Touch Provisioning requires the Omada Pro Cloud-Based Controller. Tell SourceIT which controller your site already runs and we will confirm the fit before you order.\u003c\/p\u003e\n\u003ch4\u003eWhich power supply ships with the S6500-48MPP6Y, and how much PoE does it give?\u003c\/h4\u003e\n\u003cp\u003eThe S6500-48MPP6Y ships with one PSM900-AC module, which TP-Link rates at a 701 W PoE budget. A redundant or additional module for the second bay is a separate purchase. TP-Link's datasheet gives 1,484 W with two PSM900-AC, 1,118 W with one PSM900-AC plus one PSM500-AC, 752 W with two PSM500-AC and 328 W with a single PSM500-AC. Send SourceIT your device list and we will size the power supplies to the PoE load.\u003c\/p\u003e\n\u003ch4\u003eWhat warranty does SourceIT provide?\u003c\/h4\u003e\n\u003cp\u003eFive years local Singapore warranty. Every S6500-48MPP6Y sold by SourceIT comes with a GST invoice.\u003c\/p\u003e\n\u003ch4\u003eIs stock held locally?\u003c\/h4\u003e\n\u003cp\u003eCampus-class switches such as the S6500-48MPP6Y are typically brought in on indent rather than held on the shelf. Ask SourceIT for the current lead time before committing to a project date.\u003c\/p\u003e\n\u003ch4\u003eCan SourceIT quote this for a project or tender?\u003c\/h4\u003e\n\u003cp\u003eYes. Send the bill of materials and we will quote the whole build — core and aggregation switching, access switches, power supply modules, transceivers and DAC cables — with local warranty and support.\u003c\/p\u003e\n\u003ch4\u003eIs this model available for project orders?\u003c\/h4\u003e\n\u003cp\u003eYes. TP-Link supplies this model for project deployments; contact SourceIT with your bill of materials for pricing and lead time.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"TP-Link","offers":[{"title":"Default Title","offer_id":53847619305636,"sku":"S6500-48MPP6Y","price":6440.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/S6500-48MPP6Y_UN_1.0_01_large_20240820014222b.jpg?v=1791273111","url":"https:\/\/sourceit.com.sg\/products\/tp-link-omada-pro-48-port-2-5g-stackable-l3-managed-poe-switch-with-6-25g-slots","provider":"SourceIT ","version":"1.0","type":"link"}