{"product_id":"tp-link-omada-campus-32-port-100g-stackable-l3-managed-core-switch","title":"TP-Link Omada Campus 32-Port 100G Stackable L3 Managed Core Switch","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eTP-Link Omada Campus 32-Port 100G Stackable L3 Managed Core Switch (S7500-32C) - 5 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe S7500-32C is the core switch at the top of TP-Link's Omada campus range: a 1U chassis with 32× 40\/100G QSFP28 slots, 6.4 Tbps of switching capacity and the full Layer 3 routing stack — OSPF, BGP, IS-IS, VRF and PIM multicast — needed to sit at the centre of a multi-building network and terminate the 100G uplinks from S7500 aggregation switches below it.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e32× 100G QSFP28 and 6.4 Tbps in One Rack Unit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEvery one of the 32 ports is a 40\/100G QSFP28 slot, giving the S7500-32C 6.4 Tbps of switching capacity and a 2.8 Bpps packet forwarding rate per unit. A 24 MB packet buffer absorbs the bursts that build up where many aggregation links converge, and the MAC address table holds up to 256 K entries. Management is out-of-band through a dedicated RJ45 management port, with RJ45 and USB Type-C console ports and two USB 3.0 ports alongside.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStack Up to 12 Units Over 100G\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAny QSFP28 slot can be used as a stacking port. In standalone mode up to 12 units stack into one logical switch (4 in controller mode), and with all 32 slots set as stacking ports the stacking bandwidth reaches 6.4 Tbps. TP-Link notes that stacking runs only over 100G DAC or 100G QSFP28 modules, not 40G DAC or 40G QSFP — worth planning into the optics order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFull Layer 3 Routing for the Campus Core\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe S7500-32C routes with OSPFv2\/v3, BGPv4, IS-ISv4\/v6, RIPv1\/v2 and RIPng, segments tenants or departments with VRF, and steers traffic with PBR and ECMP while uRPF drops spoofed sources. Route capacity is sized for a large campus: up to 516,096 IPv4 network routes (shared with IPv6), 22,528 host routes, 4,094 L3 interfaces and 45,056 dynamic ARP entries. PIM-SM\/DM\/SSM and 2,048 IGMP groups carry multicast video and IPTV across routed boundaries.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHigh Availability From Power Supply to Uplink\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTwo field-replaceable, hot-swappable power supply bays and five field-replaceable, hot-swappable fans keep the core serviceable without downtime — note the switch ships with one PSM550-AC and the redundant second module is bought separately. M-LAG (with dual-active detection and a peer-link LAG) lets two core switches present one logical uplink to the layer below, while VRRPv2\/v3 provides gateway redundancy, ERPS recovers ring topologies quickly and BFD detects link failure in under a second.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCampus Security and Precision Timing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAccess control spans 802.1X with RADIUS, RADSEC, MAB and guest VLAN, plus TACACS+ AAA. Dynamic ARP inspection, IP and IPv6 source guard, RA guard, DoS defend, DHCP filtering and IP\/IPv6-MAC-port binding (1,024 entries each) protect the control plane, and Secure Boot verifies firmware at start-up. IEEE 1588v2 PTP and 802.1AS support time-sensitive applications that need synchronised clocks across the network.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCentralized Management Through Omada Pro\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTP-Link positions the S7500-32C for its Omada Pro platform: the switch is managed centrally from the Omada Pro Cloud-Based, Hardware or Software Controller, with the Omada App and cloud access working through that controller. Zero-Touch Provisioning lets a replacement or new unit be pre-configured in the Omada Pro Cloud-Based Controller and pull its configuration on first boot, so a site does not need an engineer on hand with a console cable. Where a controller is not wanted, the switch is fully manageable on its own through the web GUI, CLI (console or telnet) and SNMPv1\/v2c\/v3.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIdeal For\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUniversities, hospitals, large enterprise and government campuses that need a 100G core to collapse multiple S7500 or S6500 aggregation and access stacks, with dual-core M-LAG designs and redundant power. Supplied by SourceIT with local Singapore warranty, GST invoice and project pricing on request.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eS7500-32C Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS7500-32C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Product Name\u003c\/td\u003e\n\u003ctd\u003eOmada Campus 32-Port 100G Stackable L3 Managed Core Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTP-Link Omada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eS7500 Series campus switch (Omada Pro managed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years Local Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eHardware Features\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003e32× 40\/100G QSFP28 Slots; 2× USB 3.0 Ports; 1× RJ45 Console Port; 1× USB Type-C Console Port; 1× RJ45 Management Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan Quantity\u003c\/td\u003e\n\u003ctd\u003eFive Field-replaceable and Hot-swappable Fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTwo Field-replaceable and Hot-swappable Power Supply Modules* (100–240 VAC, 50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e17.3 × 16.5 × 1.7 in (440 × 420 × 44 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRackmountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd\u003e311.2 W max @ 220V\/50Hz 25 °C; 316.7 W max @ 110V\/60Hz 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Heat Dissipation\u003c\/td\u003e\n\u003ctd\u003e1061.16 BTU\/hr @ 220V\/50Hz 25 °C; 1080.02 BTU\/hr @ 110V\/60Hz 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacket Buffer Memory\u003c\/td\u003e\n\u003ctd\u003e24 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo Frame\u003c\/td\u003e\n\u003ctd\u003e9 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStacking\u003c\/td\u003e\n\u003ctd\u003eStacking Number: 12 in standalone mode, 4 in controller mode; Stacking Port: 100G QSFP28 Slot (all uplink ports can be used as stacking ports); Stacking Bandwidth: 6.4 Tbps (All 32 QSFP28 slots set as stacking ports)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Capacity\u003c\/td\u003e\n\u003ctd\u003e6.4 Tbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacket Forwarding Rate\u003c\/td\u003e\n\u003ctd\u003e2.8 Bpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC Address Table\u003c\/td\u003e\n\u003ctd\u003eMax 256 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eLayer 3 Features\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eL3 Interface\u003c\/td\u003e\n\u003ctd\u003e4,094 (IPv4, IPv6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic Route\u003c\/td\u003e\n\u003ctd\u003e2,048 IPv4, 1,024 IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Route Table\u003c\/td\u003e\n\u003ctd\u003eMax 22,528 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv4 Network Router Entries\u003c\/td\u003e\n\u003ctd\u003eMax 516,096 (shared with IPv6 Network Router entries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv6 Network Router Entries\u003c\/td\u003e\n\u003ctd\u003eMax 258,048 (shared with IPv4 Network Router entries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECMP\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic ARP \/ ND\u003c\/td\u003e\n\u003ctd\u003e45,056 \/ 45,056\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDHCPv4 Server\u003c\/td\u003e\n\u003ctd\u003eMax 512 IP pool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDHCPv4\/v6 Relay\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eOSPFv2\/v3, RIPv1\/v2, RIPng, IS-ISv4\/v6, BGPv4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVRRP\u003c\/td\u003e\n\u003ctd\u003eVRRPv2\/v3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVRF\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulticast Routing\u003c\/td\u003e\n\u003ctd\u003ePIM-SM\/PIM-DM\/PIM-SSM; IGMPv1\/v2\/v3, 2,048 IGMP groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBFD\u003c\/td\u003e\n\u003ctd\u003e16 template numbers, 32 session numbers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePBR \/ uRPF\u003c\/td\u003e\n\u003ctd\u003eSupported \/ Supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eLayer 2, VLAN \u0026amp; Quality of Service\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eL2 \/ L2+ Features\u003c\/td\u003e\n\u003ctd\u003eLACP \/ Static LAG; STP \/ RSTP \/ MSTP \/ STP Security; ERPS; Port Isolation; Loopback Detection; Port Security; Sticky MAC; 802.3x Flow Control; Port Mirror; RSPAN; LLDP; LLDP-MED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulticast\u003c\/td\u003e\n\u003ctd\u003eIGMP Snooping; MLD Snooping; Multicast VLAN Registration (MVR); Max Multicast Table 1K (IPv4, IPv6); Fast Leave; IGMP\/MLD Snooping Querier; Multicast Filtering; Unknown Multicast Discard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM-LAG\u003c\/td\u003e\n\u003ctd\u003eM-LAG domain configuration; DAD (Dual-Active Detection); Peer-link-port LAG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePTP\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588v2 (PTPv2), IEEE 802.1AS; Clock-type: oc, bc, e2etc, p2ptc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e802.1Q VLAN\u003c\/td\u003e\n\u003ctd\u003e4K VLANs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC VLAN\u003c\/td\u003e\n\u003ctd\u003e200 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol VLAN (IEEE 802.1v)\u003c\/td\u003e\n\u003ctd\u003e16 Protocol VLAN Templates, 12 Protocol VLAN Groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQinQ (VLAN VPN)\u003c\/td\u003e\n\u003ctd\u003e256 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrivate VLAN \/ GVRP\u003c\/td\u003e\n\u003ctd\u003eSupported \/ Supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality of Service\u003c\/td\u003e\n\u003ctd\u003e8 priority queues; Port Priority; IEEE 802.1p Priority; DSCP\/ToS Priority; SP\/WRR per queue with queue weight config; Rate Limit; Storm Control; Voice VLAN; WRED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced \/ ISP Features\u003c\/td\u003e\n\u003ctd\u003eAutomatic Device Discovery‡; Batch Configuration‡; Batch Firmware Upgrading‡; Intelligent Network Monitoring‡; Abnormal Event Warnings‡; Unified Configuration‡; Reboot Schedule‡; 802.3ah Ethernet Link OAM; L2PT (Layer 2 Protocol Tunneling); Device Link Detect Protocol (DLDP); DDM; sFlow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eSecurity\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP-MAC-Port Binding\u003c\/td\u003e\n\u003ctd\u003e1,024 Entries; ARP Scanning; Manual Binding; DHCP Snooping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv6-MAC-Port Binding\u003c\/td\u003e\n\u003ctd\u003e1,024 Entries; DHCPv6 Snooping; Manual Binding; ND Snooping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP Inspection \/ ND Detection\u003c\/td\u003e\n\u003ctd\u003eDynamic ARP Inspection \/ ND Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource Guard\u003c\/td\u003e\n\u003ctd\u003eIP Source Guard; IPv6 Source Guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRA Guard\u003c\/td\u003e\n\u003ctd\u003e30 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther Protection\u003c\/td\u003e\n\u003ctd\u003eDoS Defend; DHCP Filter; ACL; Secure boot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e802.1X\u003c\/td\u003e\n\u003ctd\u003eRadius Authentication; Radius Accounting; Radius Server Load Balancing; RADSEC; Guest VLAN; VLAN Assignment; MAB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAAA\u003c\/td\u003e\n\u003ctd\u003eAAA (including TACACS+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eManagement\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOmada App\u003c\/td\u003e\n\u003ctd\u003eYes, through Omada Pro Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCentralized Management\u003c\/td\u003e\n\u003ctd\u003eOmada Pro Cloud-Based Controller, Omada Pro Hardware Controller, Omada Pro Software Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCloud Access\u003c\/td\u003e\n\u003ctd\u003eYes, through Omada Pro Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-Touch Provisioning\u003c\/td\u003e\n\u003ctd\u003eYes. Requiring the use of Omada Pro Cloud-Based Controller.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Features\u003c\/td\u003e\n\u003ctd\u003eWeb-based GUI; Command Line Interface (CLI) through console port, telnet; SNMPv1\/v2c\/v3 (Trap\/Inform, RMON 1, 2, 3, 9 groups); SDM Template; DHCP\/BOOTP Client; 802.1ab LLDP\/LLDP-MED; DHCP Auto Install; Dual Image, Dual Configuration; CPU Monitoring; Password Recovery; SNTP; System Log\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 °C to 45 °C (23 °F to 113 °F) @ 300 meters; -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters; -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 °C to 70 °C (-40 °F to 158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e10–90% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Humidity\u003c\/td\u003e\n\u003ctd\u003e5–90% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eTP-Link Footnotes\u003c\/h4\u003e\n\u003cp\u003e\u003cem\u003e*Ships with one PSM550-AC module by default, and another field-replaceable redundant power supply requires a separate purchase.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e‡These functions require the use of the Omada Pro SDN Controller. Zero-Touch Provisioning requires the use of the Omada Pro Cloud-Based Controller.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSupports 12 units of physical stacking in standalone mode.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe 100G QSFP28 slots support stacking only through 100G DAC\/100G QSFP28 modules rather than 40G DAC\/40G QSFP modules.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Software Support\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eThe S7500-32C is an Omada Pro campus switch. TP-Link lists the Omada Pro controllers — not the standard Omada SDN controller — as its centralized-management platform, so plan the controller with the switch.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOmada Pro SDN Controller\u003c\/td\u003e\n\u003ctd\u003eSupported — centralized management through the Omada Pro Cloud-Based Controller, Omada Pro Hardware Controller or Omada Pro Software Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOmada App\u003c\/td\u003e\n\u003ctd\u003eSupported — through an Omada Pro Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCloud Access\u003c\/td\u003e\n\u003ctd\u003eSupported — through an Omada Pro Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-Touch Provisioning\u003c\/td\u003e\n\u003ctd\u003eSupported — requires the Omada Pro Cloud-Based Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandalone Management\u003c\/td\u003e\n\u003ctd\u003eSupported — web-based GUI, CLI (console port, telnet) and SNMPv1\/v2c\/v3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStacking Mode Limit\u003c\/td\u003e\n\u003ctd\u003e12 units in standalone mode; 4 units in controller mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransceivers \u0026amp; Cabling\u003c\/td\u003e\n\u003ctd\u003e40\/100G QSFP28 slots. Stacking only through 100G DAC\/100G QSFP28 modules rather than 40G DAC\/40G QSFP modules.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eTP-Link's note: these functions require the use of the Omada Pro SDN Controller. Zero-Touch Provisioning requires the use of the Omada Pro Cloud-Based Controller.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat’s in the Box\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eS7500-32C Switch, Power Cord, RJ45 Console Cable, Locking Strap, Rackmount Kit, Rubber Feet, Quick Installation Guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eOrdering Information\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS7500-32C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Retail Price (incl. GST)\u003c\/td\u003e\n\u003ctd\u003eS$53,999.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Shipped\u003c\/td\u003e\n\u003ctd\u003e1× PSM550-AC (550 W AC Power Supply Module), installed by default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant Power Supply\u003c\/td\u003e\n\u003ctd\u003ePSM550-AC — second module sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.omadanetworks.com\/sg\/business-networking\/omada-switch-campus\/s7500-32c\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Omada S7500-32C product page\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/support.omadanetworks.com\/sg\/document\/106694\/\" target=\"_blank\" rel=\"noopener\"\u003eS7500-32C datasheet (Omada support, PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.omadanetworks.com\/sg\/support\/download\/s7500-32c\/\" target=\"_blank\" rel=\"noopener\"\u003eS7500-32C firmware, guides \u0026amp; downloads (Omada support)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.omadanetworks.com\/sg\/\" target=\"_blank\" rel=\"noopener\"\u003eOmada Networks Singapore\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — S7500-32C\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eDoes the S7500-32C need an Omada controller?\u003c\/h4\u003e\n\u003cp\u003eNo. The S7500-32C can be run standalone through its web-based GUI or the CLI (console port or telnet). TP-Link lists the Omada Pro Cloud-Based, Hardware and Software Controllers for centralized management; the Omada App and cloud access work through an Omada Pro Controller, and Zero-Touch Provisioning requires the Omada Pro Cloud-Based Controller. Tell SourceIT which controller your site already runs and we will confirm the fit before you order.\u003c\/p\u003e\n\u003ch4\u003eDoes the S7500-32C ship with redundant power supplies?\u003c\/h4\u003e\n\u003cp\u003eNot as standard. The S7500-32C has two field-replaceable, hot-swappable power supply bays (100–240 VAC, 50\/60 Hz), but TP-Link ships it with one PSM550-AC module by default. The second, redundant module is a separate purchase — add a PSM550-AC to the order if the switch must keep running through a power-supply failure. SourceIT can supply it with the switch.\u003c\/p\u003e\n\u003ch4\u003eWhat warranty does SourceIT provide?\u003c\/h4\u003e\n\u003cp\u003eFive years local Singapore warranty. Every S7500-32C sold by SourceIT comes with a GST invoice.\u003c\/p\u003e\n\u003ch4\u003eIs stock held locally?\u003c\/h4\u003e\n\u003cp\u003eCampus-class switches such as the S7500-32C are typically brought in on indent rather than held on the shelf. Ask SourceIT for the current lead time before committing to a project date.\u003c\/p\u003e\n\u003ch4\u003eCan SourceIT quote this for a project or tender?\u003c\/h4\u003e\n\u003cp\u003eYes. Send the bill of materials and we will quote the whole build — core and aggregation switching, access switches, power supply modules, transceivers and DAC cables — with local warranty and support.\u003c\/p\u003e\n\u003ch4\u003eIs this model available for project orders?\u003c\/h4\u003e\n\u003cp\u003eYes. TP-Link supplies this model for project deployments; contact SourceIT with your bill of materials for pricing and lead time.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"TP-Link","offers":[{"title":"Default Title","offer_id":53847617896612,"sku":"S7500-32C","price":18055.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/S7500-32C_UN_1.0_overview_01_large_20250829072455a.jpg?v=1791272750","url":"https:\/\/sourceit.com.sg\/products\/tp-link-omada-campus-32-port-100g-stackable-l3-managed-core-switch","provider":"SourceIT ","version":"1.0","type":"link"}