{"product_id":"hpe-cray-supercomputing-ex2500-liquid-cooled-supercomputer-rack-up-to-24-compute-blades-in-rack-cdu-hpe-slingshot","title":"HPE Cray Supercomputing EX2500 Liquid-Cooled Supercomputer Rack - Up to 24 Compute Blades, In-Rack CDU, HPE Slingshot","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n.pd-video { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; margin: 10px 0 18px; }\n.pd-video iframe { position: absolute; top: 0; left: 0; width: 100%; height: 100%; border: 0; }\n\u003c\/style\u003e\n\u003ch2\u003eHPE Cray Supercomputing EX2500 Liquid-Cooled Supercomputer Rack, Up to 3 Compute Chassis, Up to 24 Compute Blades and 24 HPE Slingshot Switch Blades, In-Rack Cooling Distribution, Up to 141 kVA per Rack\u003c\/h2\u003e\n\u003ch3\u003eExascale Architecture in a Data Centre Footprint\u003c\/h3\u003e\n\u003cp\u003eThe HPE Cray Supercomputing EX2500 uses the same blades, switches and sealed closed-loop liquid cooling as the EX4000, in a smaller rack with the cooling distribution units built in. Each rack holds up to three compute chassis with up to 24 compute or accelerator blades and up to 24 HPE Slingshot switch blades.\u003c\/p\u003e\n\u003ch3\u003eLiquid Cooled, with Room for Air-Cooled Hardware\u003c\/h3\u003e\n\u003cp\u003eUp to two 4U in-rack CDUs of 70 kW each remove the heat, and in certain configurations part of the rack can be used for air-cooled hardware.\u003c\/p\u003e\n\u003cp\u003eSourceIT supplies HPE Cray Supercomputing systems in Singapore as a project sale: sizing, site readiness, delivery and HPE Services are scoped and quoted per deployment.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eHPE Cray Supercomputing EX2500 Datasheet - Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eHPE Cray Supercomputing EX2500 liquid-cooled rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompute Chassis\u003c\/td\u003e\n\u003ctd\u003eUp to 3 per rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlade Slots\u003c\/td\u003e\n\u003ctd\u003eUp to 24 compute or accelerator blades; up to 24 HPE Slingshot switch blades\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompute Blades\u003c\/td\u003e\n\u003ctd\u003eEX4252: four 2-socket AMD EPYC nodes\u003cbr\u003eEX254n: two 4-socket NVIDIA GH200 Grace Hopper nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterconnect\u003c\/td\u003e\n\u003ctd\u003eHPE Slingshot switch blade: 64 ports at 100\/200 Gb\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e3 power shelves, 12 x 15 kW rectifiers; up to 141 kVA at 480 V or 128 kVA at 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eSealed closed-loop, fanless direct liquid cooling; up to two 4U in-rack CDUs, 70 kW each; supply water up to 32 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e2302 x 900 x 1719 mm with cable trays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Weight\u003c\/td\u003e\n\u003ctd\u003e1,462 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eHPE Cray OS, HPE Cray System Management or HPE Performance Cluster Manager, HPE Cray Programming Environment, Slurm or PBS Professional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003ePer HPE quotation and support contract\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eSite Requirements \u0026amp; Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 141 kVA of three-phase power per rack\u003c\/li\u003e\n\u003cli\u003eFacility water connection for the in-rack cooling distribution units\u003c\/li\u003e\n\u003cli\u003eFloor loading for a rack of up to 1,462 kg, plus delivery path\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EX2500 is designed and quoted per project and pricing is by formal quotation. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e or use Request for Quotation.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hpe.com\/us\/en\/collaterals\/collateral.a00094635enw.html\" target=\"_blank\" rel=\"noopener\"\u003eHPE Cray Supercomputing EX QuickSpecs\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hpe.com\/us\/en\/products\/supercomputing\/cray.html\" target=\"_blank\" rel=\"noopener\"\u003eHPE Cray Supercomputing - product page\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions - HPE Cray Supercomputing EX2500\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eHow is the EX2500 different from the EX4000?\u003c\/h3\u003e\n\u003cp\u003eIt uses the same blades and switches but holds up to 3 chassis and 24 blades, with the cooling distribution units inside the rack.\u003c\/p\u003e\n\u003ch3\u003eDoes it need facility water?\u003c\/h3\u003e\n\u003cp\u003eYes. It is a direct liquid cooled system.\u003c\/p\u003e\n\u003ch3\u003eHow do I buy it in Singapore?\u003c\/h3\u003e\n\u003cp\u003eEmail sales@sourceit.com.sg. SourceIT will arrange sizing, site readiness and a formal quotation with HPE.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eVideo: HPE Cray Supercomputing\u003c\/h3\u003e\n\u003cdiv class=\"pd-video\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/HzB4GxAJifM\" title=\"HPE Cray Supercomputing; built for the biggest questions | HPE\" allowfullscreen loading=\"lazy\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"HPE","offers":[{"title":"Default Title","offer_id":57619685605540,"sku":"HPE-CRAY-EX2500","price":5520000.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/hpe-cray-ex2500-rack.png?v=1794818547","url":"https:\/\/sourceit.com.sg\/products\/hpe-cray-supercomputing-ex2500-liquid-cooled-supercomputer-rack-up-to-24-compute-blades-in-rack-cdu-hpe-slingshot","provider":"SourceIT ","version":"1.0","type":"link"}