{"product_id":"eaton-rack-pdu-g4-managed-0u-vertical-pdu-three-phase-16a-iec-60309-input-11-kw-12x-c13-12x-c39-outlet-metering","title":"Eaton Rack PDU G4 Managed 0U Vertical PDU, Three-phase 16A IEC 60309 Input, 11 kW, 12x C13 + 12x C39, Outlet Metering","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eEaton Rack PDU G4 Managed 0U Three-phase 16A 11 kW Rack PDU (EVMAF316A, 9001-22332) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003ePer-Outlet Measurement and Remote Outlet Control\u003c\/h3\u003e\n\u003cp\u003eThe Eaton Rack PDU G4 EVMAF316A is a Managed 0U (vertical) rack PDU. It takes a three-phase 16A feed through an IEC 60309 16A three-phase plug on a 3 m cord and distributes up to 11 kW to 24 outlets (12 x IEC C13 + 12 x IEC C39). Eaton lists its outlets as switchable, with remote on\/off, reboot and sequential start-up control, 1% measurement accuracy at outlet level (V, W, A) and 1% IEC Class 1 billing-grade measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eFor a Singapore data centre, colocation cage or remote branch rack, that means you can power-cycle a hung server or switch without a site visit, and see exactly which device is drawing what — cutting downtime and callout costs.\u003c\/p\u003e\n\u003ch3\u003eGigabit Networking, Modern Protocols and Cybersecurity\u003c\/h3\u003e\n\u003cp\u003eEaton fits the Rack PDU G4 with a gigabit network card with 2 x Gb ports, supporting RestAPI, Modbus TCP, SNMP, LDAP and HTTPS. Up to 32 PDUs can be cascaded, and the network control module is hot-swappable. Eaton also lists power sharing between two network modules.\u003c\/p\u003e\n\u003cp\u003eEaton lists compliance with the UL 2900-1 and IEC 62443-4-2 cybersecurity standards — useful where IT security teams audit every networked device in the data centre.\u003c\/p\u003e\n\u003ch3\u003eC39 Outlets That Take Either C14 or C20 Plugs\u003c\/h3\u003e\n\u003cp\u003eEaton describes the C39 outlet as versatile: it accepts either a C14 or a C20 power cord plug. With 12 x IEC C13 + 12 x IEC C39, you can mix standard servers and switches with higher-power C20-corded equipment without re-planning the rack. Eaton also specifies high-retention outlets designed to fit standard power cords and support P-Lock power cords.\u003c\/p\u003e\n\u003ch3\u003eRated for Hot Aisles: 0–60 °C Operation\u003c\/h3\u003e\n\u003cp\u003eEaton rates the Rack PDU G4 for operation from 0 °C to 60 °C, which gives margin at the back of a densely packed rack where exhaust air collects. The chassis is aluminium, finished in black.\u003c\/p\u003e\n\u003ch3\u003eSupplied Locally with GST Invoice and 2-Year Warranty\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the Eaton Rack PDU G4 range in Singapore with a full GST invoice and local warranty support. Eaton's Singapore price list gives a 2-year warranty for ePDUs.\u003c\/p\u003e\n\u003cp\u003eNeed help choosing an input plug or outlet mix? Email sales@sourceit.com.sg with your rack layout and supply type.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eEaton EVMAF316A Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eEaton Rack PDU G4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue Number\u003c\/td\u003e\n\u003ctd\u003eEVMAF316A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003e9001-22332\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Code\u003c\/td\u003e\n\u003ctd\u003ePDU G4 MA 0U 309 16A 3P 12xC13,12xC39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eEaton Rack PDU G4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eManaged Rack PDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e0U (vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Control\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003e2 years (Eaton Singapore price list), supplied by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePower\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 16A three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e240\/415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eOutlets\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Outlets\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Types\u003c\/td\u003e\n\u003ctd\u003e12 x IEC C13 + 12 x IEC C39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC39 Outlets\u003c\/td\u003e\n\u003ctd\u003eAccept C14 or C20 power cord plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Retention\u003c\/td\u003e\n\u003ctd\u003eHigh-retention outlets (support P-Lock power cords)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eMetering \u0026amp; Network\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eOutlet-level measurement (V, W, A), 1% accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e1% IEC Class 1 (billing grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchable Outlets\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork\u003c\/td\u003e\n\u003ctd\u003eGigabit network card, 2 x Gb ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eRestAPI, Modbus TCP, SNMP, LDAP, HTTPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Ports\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 Sockets\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Module\u003c\/td\u003e\n\u003ctd\u003eHot-swappable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Sharing\u003c\/td\u003e\n\u003ctd\u003eBetween two network modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Control\u003c\/td\u003e\n\u003ctd\u003eOn\/Off, reboot, sequential start-up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCascading\u003c\/td\u003e\n\u003ctd\u003eUp to 32 PDUs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass Configuration\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCybersecurity\u003c\/td\u003e\n\u003ctd\u003eUL 2900-1 and IEC 62443-4-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e1000 x 52 x 53 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial \/ Colour\u003c\/td\u003e\n\u003ctd\u003eAluminium \/ Black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eIEC 62368-1, EN IEC 63000, CE, EAC, UKCA, Cm, Ukr, IEC\/EN 61000-6-2, IEC\/EN 61000-6-4, EN 61000-3-2, EN 61000-3-3, CISPR 35\/EN 55035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Software Support\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat It Is Suited To\u003c\/h3\u003e\n\u003cp\u003eThe EVMAF316A suits IT equipment with IEC C14 or C20 power cords — rack servers, storage arrays, switches, routers and firewalls. Keep the total connected load within 11 kW and within the rating of the circuit that feeds the PDU, and balance loads across the phases.\u003c\/p\u003e\n\u003ch3\u003eMonitoring and Integration\u003c\/h3\u003e\n\u003cp\u003eManage the PDU from a web browser over HTTPS, or bring it into an existing NMS, BMS or DCIM platform over SNMP, Modbus TCP or the RestAPI. LDAP support allows central user authentication. Outlets can be switched remotely and measured individually.\u003c\/p\u003e\n\u003ch3\u003eInput Plug and Supply\u003c\/h3\u003e\n\u003cp\u003eThe input is an IEC 60309 16A three-phase plug on a 3 m cord. Your rack feed needs the matching IEC 60309 16A three-phase socket, installed by a licensed electrician; a standard BS 1363 wall socket cannot feed this PDU.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Rack PDU G4 Switched \u0026amp; Managed Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cp\u003eEaton's Singapore specification page does not list package contents for the EVMAF316A — ask us to confirm what ships in the box.\u003c\/p\u003e\n\u003ch3\u003eEaton Rack PDU G4 Switched \u0026amp; Managed Range — Ordering Information\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVSWFC20A\u003c\/td\u003e\n\u003ctd\u003eSwitched, 0U, 1-phase, C20, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e12 x C13 + 12 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22363\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVSWF116A\u003c\/td\u003e\n\u003ctd\u003eSwitched, 0U, 1-phase, IEC 60309 16A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e12 x C13 + 12 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVSWF132A\u003c\/td\u003e\n\u003ctd\u003eSwitched, 0U, 1-phase, IEC 60309 32A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003e12 x C13 + 12 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22355\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVSWF316A\u003c\/td\u003e\n\u003ctd\u003eSwitched, 0U, 3-phase, IEC 60309 16A, 11 kW\u003c\/td\u003e\n\u003ctd\u003e12 x C13 + 12 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVMAFC20A\u003c\/td\u003e\n\u003ctd\u003eManaged, 0U, 1-phase, C20, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e12 x C13 + 12 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVMAF116A\u003c\/td\u003e\n\u003ctd\u003eManaged, 0U, 1-phase, IEC 60309 16A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e12 x C13 + 12 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22337\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVMAF132A\u003c\/td\u003e\n\u003ctd\u003eManaged, 0U, 1-phase, IEC 60309 32A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003e12 x C13 + 12 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVMAF132X\u003c\/td\u003e\n\u003ctd\u003eManaged, 0U, 1-phase, IEC 60309 32A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003e24 x C13 + 18 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22349\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEVMAF316A (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManaged, 0U, 3-phase, IEC 60309 16A, 11 kW\u003c\/td\u003e\n\u003ctd\u003e12 x C13 + 12 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22332\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVMAF316X\u003c\/td\u003e\n\u003ctd\u003eManaged, 0U, 3-phase, IEC 60309 16A, 11 kW\u003c\/td\u003e\n\u003ctd\u003e24 x C13 + 18 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22346\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVMAF332A\u003c\/td\u003e\n\u003ctd\u003eManaged, 0U, 3-phase, IEC 60309 32A, 22 kW\u003c\/td\u003e\n\u003ctd\u003e12 x C13 + 12 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22329\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVMAF332X\u003c\/td\u003e\n\u003ctd\u003eManaged, 0U, 3-phase, IEC 60309 32A, 22 kW\u003c\/td\u003e\n\u003ctd\u003e24 x C13 + 18 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVMAF332C\u003c\/td\u003e\n\u003ctd\u003eManaged, 0U, 3-phase, IEC 60309 32A, 22 kW\u003c\/td\u003e\n\u003ctd\u003e24 x C13 + 24 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22373\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eRack PDU G4 Basic and Metered Input models are also available on request.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton specifications\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/sg\/en-us\/skuPage.EVMAF316A.specifications.html\" target=\"_blank\" rel=\"noopener\"\u003eEaton EVMAF316A Specifications — Eaton Singapore\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton brochure\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/backup-power-ups-surge-it-power-distribution\/power-distribution-for-it-equipment\/eaton-rackpdug4-emea\/eaton-rack-pdu-g4-resources---emea\/eaton-rackpdug4-brochure-br155022-en-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEaton Rack PDU G4 Brochure BR155022 (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical drawing\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/backup-power-ups-surge-it-power-distribution\/power-distribution-for-it-equipment\/eaton-rackpdug4-emea\/eaton-rack-pdu-g4-resources---emea\/eaton-dpq-rackpdug4-outline-drawing-9001-22332-EVMAF316A-en-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEaton EVMAF316A Outline Drawing (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/backup-power-ups-surge-it-power-distribution\/power-distribution-for-it-equipment\/eaton-rackpdug4-emea\/eaton-rack-pdu-g4-resources---emea\/eaton-rackpdu-g4-quickguide-emea-en-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEaton Rack PDU G4 Quick Guide (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/backup-power-ups-surge-it-power-distribution\/power-distribution-for-it-equipment\/eaton-rack-pdu-g4\/user-guides\/eaton-rack-pdu-g4-installation-and-setup-guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEaton Rack PDU G4 Installation and Setup Guide (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eNeed a PDF sent directly? Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eEVMAF316A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — Eaton EVMAF316A\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat does the EVMAF316A measure and control?\u003c\/h3\u003e\n\u003cp\u003eEaton lists 1% measurement accuracy at outlet level (V, W, A), 1% IEC Class 1 billing-grade measurement accuracy, and switchable outlets with on\/off, reboot and sequential start-up control.\u003c\/p\u003e\n\u003ch3\u003eHow do I access it remotely?\u003c\/h3\u003e\n\u003cp\u003eOver the gigabit network card (2 x Gb ports) using a web browser (HTTPS), SNMP, Modbus TCP or RestAPI. LDAP is supported for central authentication, and up to 32 PDUs can be cascaded.\u003c\/p\u003e\n\u003ch3\u003eHow many devices can I connect?\u003c\/h3\u003e\n\u003cp\u003e24 outlets: 12 x IEC C13 + 12 x IEC C39. C13 outlets take the common C14 cord; Eaton's C39 outlets take either a C14 or a C20 plug. Keep the total load within 11 kW.\u003c\/p\u003e\n\u003ch3\u003eWhat supply do I need?\u003c\/h3\u003e\n\u003cp\u003eA three-phase 16A feed with a matching IEC 60309 16A three-phase socket (240\/415 V), installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eHow hot can the rack get?\u003c\/h3\u003e\n\u003cp\u003eEaton rates the Rack PDU G4 for 0–60 °C operation.\u003c\/p\u003e\n\u003ch3\u003eWhat warranty do I get?\u003c\/h3\u003e\n\u003cp\u003e2 years per Eaton's Singapore price list, supplied by SourceIT with local Singapore support and a GST invoice.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/eUynCPtkVVs\" title=\"Eaton Rack PDU G4\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":51487377293476,"sku":"9001-22332","price":2561.28,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/EVMAF316A_C.jpg?v=1790217116","url":"https:\/\/sourceit.com.sg\/products\/eaton-rack-pdu-g4-managed-0u-vertical-pdu-three-phase-16a-iec-60309-input-11-kw-12x-c13-12x-c39-outlet-metering","provider":"SourceIT ","version":"1.0","type":"link"}