{"product_id":"eaton-rack-pdu-g4-basic-0u-vertical-pdu-three-phase-16a-iec-60309-input-24x-c13-18x-c39","title":"Eaton Rack PDU G4 Basic 0U Vertical PDU, Three-phase 16A IEC 60309 Input, 24x C13 + 18x C39","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eEaton Rack PDU G4 Basic 0U Three-phase 16A 11 kW Rack PDU (EVBAF316X, 9001-22347) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eSimple, Dependable Power Distribution for Your Rack\u003c\/h3\u003e\n\u003cp\u003eThe Eaton Rack PDU G4 EVBAF316X is a Basic 0U (vertical) rack PDU that takes a three-phase 16A feed through an IEC 60309 16A three-phase plug on a 3 m cord and distributes up to 11 kW to 42 outlets: 24 x IEC C13 + 18 x IEC C39. There is no network or metering to configure — it is straightforward, reliable power distribution for servers, storage and network equipment.\u003c\/p\u003e\n\u003cp\u003eIt mounts vertically in the rear side channel of the rack, keeping rack units free for equipment — a good fit for Singapore server rooms, comms cabinets and colocation racks where every U counts.\u003c\/p\u003e\n\u003ch3\u003eC39 Outlets That Take Either C14 or C20 Plugs\u003c\/h3\u003e\n\u003cp\u003eEaton describes the C39 outlet as versatile: it accepts either a C14 or a C20 power cord plug. With 18 C39 outlets alongside 24 C13 outlets, you can mix standard servers and switches with higher-power C20-corded equipment without re-planning the rack. Eaton also specifies high-retention outlets to help keep cords seated.\u003c\/p\u003e\n\u003ch3\u003eRated for Hot Aisles: 0–60 °C Operation\u003c\/h3\u003e\n\u003cp\u003eEaton rates the Rack PDU G4 for operation from 0 °C to 60 °C, which gives margin at the back of a densely packed rack where exhaust air collects. The chassis is aluminium, finished in black.\u003c\/p\u003e\n\u003ch3\u003eSupplied Locally with GST Invoice and 2-Year Warranty\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the Eaton Rack PDU G4 range in Singapore with a full GST invoice and local warranty support. Eaton's Singapore price list gives a 2-year warranty for ePDUs.\u003c\/p\u003e\n\u003cp\u003eNeed help choosing an input plug or outlet mix? Email sales@sourceit.com.sg with your rack layout and supply type.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eEaton EVBAF316X Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eEaton Rack PDU G4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue Number\u003c\/td\u003e\n\u003ctd\u003eEVBAF316X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003e9001-22347\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eEaton Rack PDU G4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eBasic Rack PDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e0U (vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Control\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003e2 years (Eaton Singapore price list), supplied by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePower\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 16A three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e240\/415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eOutlets\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Outlets\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Types\u003c\/td\u003e\n\u003ctd\u003e24 x IEC C13 + 18 x IEC C39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC39 Outlets\u003c\/td\u003e\n\u003ctd\u003eAccept C14 or C20 power cord plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Retention\u003c\/td\u003e\n\u003ctd\u003eHigh-retention outlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eMonitoring\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork \/ SNMP\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchable Outlets\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e1730 x 52 x 53 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial \/ Colour\u003c\/td\u003e\n\u003ctd\u003eAluminium \/ Black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eIEC 62368-1, EN IEC 63000, CE, EAC, UKCA, Cm, Ukr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Software Support\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat It Is Suited To\u003c\/h3\u003e\n\u003cp\u003eThe EVBAF316X suits IT equipment with IEC C14 or C20 power cords — rack servers, storage arrays, switches, routers and firewalls. Keep the total connected load within 11 kW and within the rating of the circuit that feeds the PDU.\u003c\/p\u003e\n\u003ch3\u003eMonitoring\u003c\/h3\u003e\n\u003cp\u003eThis is a Basic model: no metering, no network port and no outlet switching. If you need to see load remotely or report energy use, choose a Rack PDU G4 Metered Input model; for remote outlet on\/off, ask us about Switched and Managed models.\u003c\/p\u003e\n\u003ch3\u003eInput Plug and Supply\u003c\/h3\u003e\n\u003cp\u003eThe input is an IEC 60309 16A three-phase plug on a 3 m cord. Your rack feed needs the matching IEC 60309 socket, installed by a licensed electrician; a standard BS 1363 wall socket cannot feed this PDU.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Rack PDU G4 Basic Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cp\u003eEaton Rack PDU G4 with user documentation. Eaton's page for this model does not itemise the carton contents, so confirm mounting hardware with us before ordering if it matters to your installation.\u003c\/p\u003e\n\u003ch3\u003eEaton Rack PDU G4 Basic Range — Ordering Information\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVBAFC20A\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, C20, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e12 x C13 + 12 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22364\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVBAF116A\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC 60309 16A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e12 x C13 + 12 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22362\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVBAF132A\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC 60309 32A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003e12 x C13 + 12 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22356\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVBAF132X\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC 60309 32A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003e24 x C13 + 18 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEVBAF316X (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 16A, 11 kW\u003c\/td\u003e\n\u003ctd\u003e24 x C13 + 18 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22347\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVBAF332X\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 32A, 22 kW\u003c\/td\u003e\n\u003ctd\u003e24 x C13 + 18 x C39\u003c\/td\u003e\n\u003ctd\u003e9001-22352\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eRack PDU G4 Metered Input, Switched and Managed models are also available on request.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton specifications\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/sg\/en-us\/skuPage.EVBAF316X.specifications.html\" target=\"_blank\" rel=\"noopener\"\u003eEaton EVBAF316X Specifications — Eaton Singapore\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton brochure\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/backup-power-ups-surge-it-power-distribution\/power-distribution-for-it-equipment\/eaton-rackpdug4-emea\/eaton-rack-pdu-g4-resources---emea\/eaton-rackpdug4-brochure-br155022-en-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEaton Rack PDU G4 Brochure BR155022 (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical drawing\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/backup-power-ups-surge-it-power-distribution\/power-distribution-for-it-equipment\/eaton-rackpdug4-emea\/eaton-rack-pdu-g4-resources---emea\/eaton-dpq-rackpdug4-outline-drawing-9001-22347-EVBAF316X-en-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEaton EVBAF316X Outline Drawing (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/backup-power-ups-surge-it-power-distribution\/power-distribution-for-it-equipment\/eaton-rackpdug4-emea\/eaton-rack-pdu-g4-resources---emea\/eaton-rackpdu-g4-quickguide-emea-en-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEaton Rack PDU G4 Quick Guide (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eNeed a PDF sent directly? Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eEVBAF316X\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — Eaton EVBAF316X\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eDoes the EVBAF316X have metering or a network port?\u003c\/h3\u003e\n\u003cp\u003eNo. It is a Basic PDU with no metering, SNMP, Ethernet or outlet switching. For remote load monitoring, choose a Rack PDU G4 Metered Input model.\u003c\/p\u003e\n\u003ch3\u003eHow many devices can I connect?\u003c\/h3\u003e\n\u003cp\u003e42 outlets: 24 x IEC C13 + 18 x IEC C39. C13 outlets take the common C14 cord; Eaton's C39 outlets take either a C14 or a C20 plug. Keep the total load within 11 kW.\u003c\/p\u003e\n\u003ch3\u003eWhat supply do I need?\u003c\/h3\u003e\n\u003cp\u003eA three-phase 16A feed with a matching IEC 60309 socket (240\/415 V), installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eHow hot can the rack get?\u003c\/h3\u003e\n\u003cp\u003eEaton rates the Rack PDU G4 for 0–60 °C operation.\u003c\/p\u003e\n\u003ch3\u003eWhat warranty do I get?\u003c\/h3\u003e\n\u003cp\u003e2 years per Eaton's Singapore price list, supplied by SourceIT with local Singapore support and a GST invoice.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/eUynCPtkVVs\" title=\"Eaton Rack PDU G4\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":51487333875876,"sku":"9001-22347","price":1185.7,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/EVBAF316X_C.jpg?v=1790209820","url":"https:\/\/sourceit.com.sg\/products\/eaton-rack-pdu-g4-basic-0u-vertical-pdu-three-phase-16a-iec-60309-input-24x-c13-18x-c39","provider":"SourceIT ","version":"1.0","type":"link"}