{"product_id":"eaton-flexpdu-g2-switched-1u-horizontal-rack-pdu-single-phase-16a-iec-c20-input-8x-c13-remote-outlet-switching","title":"Eaton FlexPDU G2 Switched 1U Horizontal Rack PDU, Single-phase 16A IEC C20 Input, 8x C13, Remote Outlet Switching","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eEaton FlexPDU G2 Switched 1U Single-phase 16A Rack PDU (FLXTSWC20C1, P-FLXTSWC20C1) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eSwitch Any Outlet Remotely\u003c\/h3\u003e\n\u003cp\u003eThe Eaton FlexPDU G2 FLXTSWC20C1 is a Switched rack PDU from Eaton's second-generation FlexPDU range. It takes a single-phase 16A IEC C20 feed and distributes up to 3.7 kW to 8 IEC outlets (8 x IEC C13). Eaton's Switched models add remote on\/off outlet switching, user-defined power-on\/power-off sequences with delays and grouped outlet control to full-PDU metering with ±1% accuracy.\u003c\/p\u003e\n\u003cp\u003eFor Singapore server rooms, branch comms racks and colocation cages, that means a hung server, router or firewall can be power-cycled from your desk instead of waiting for someone to get on site, and equipment can be brought back up in a set order after a power event.\u003c\/p\u003e\n\u003ch3\u003eFull Network Management, Built for Security\u003c\/h3\u003e\n\u003cp\u003eEaton's FlexPDU G2 Switched models include a network management module with a 10\/100 Mbps Ethernet port, full management through a web browser or SNMP, and support for HTTPS, SSH v2, SNMP, SMTP, DHCP, RADIUS, NTP and TELNET over IPv4 and IPv6. Firmware can be upgraded remotely, up to 8 external sensors can be connected, and the range supports cascade (daisy-chain) connection.\u003c\/p\u003e\n\u003cp\u003eEaton states the FlexPDU G2 network models meet the UL 2900-1 and IEC 62443-4-1 cybersecurity standards.\u003c\/p\u003e\n\u003ch3\u003eBuilt for Safety in the Rack\u003c\/h3\u003e\n\u003cp\u003eEaton equips every outlet with an anti-ejection mechanism so power cords are held firmly in place, uses pure copper for the main circuit conductors, and provides additional enclosure grounding points. Models rated 32A and above are fitted with hydraulic-magnetic circuit breakers.\u003c\/p\u003e\n\u003ch3\u003eSupplied Locally with GST Invoice and 2-Year Warranty\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the FlexPDU G2 range in Singapore with a full GST invoice and local warranty support. Eaton's FlexPDU G2 brochure and Eaton's Singapore price list both give a 2-year warranty.\u003c\/p\u003e\n\u003cp\u003eNeed help choosing an input plug or outlet mix? Email sales@sourceit.com.sg with your rack layout and supply type.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eEaton FLXTSWC20C1 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eEaton FlexPDU G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue Number\u003c\/td\u003e\n\u003ctd\u003eFLXTSWC20C1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eP-FLXTSWC20C1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eEaton FlexPDU 2nd Generation (G2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSwitched rack PDU (remote outlet switching, full-PDU metering, network management)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e1U horizontal (19-inch rack mount)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2 years (Eaton FlexPDU G2 brochure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003e2 years, supplied by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003ePower\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC C20 plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Rating\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e230V (Eaton Singapore price list)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Power\u003c\/td\u003e\n\u003ctd\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Cord Length\u003c\/td\u003e\n\u003ctd\u003e2.5 m (Eaton brochure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eOutlets\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Outlets\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Types\u003c\/td\u003e\n\u003ctd\u003e8 x IEC C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Retention\u003c\/td\u003e\n\u003ctd\u003eAnti-ejection mechanism on all outlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eMetering \u0026amp; Network\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eFull PDU measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhole-PDU Measurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd\u003eRemote on\/off switching of individual outlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Sequencing\u003c\/td\u003e\n\u003ctd\u003eUser-defined power-on \/ power-off sequence with delays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Groups\u003c\/td\u003e\n\u003ctd\u003eGrouped outlet control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps Ethernet; web and SNMP management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eHTTPS, SSH v2, SNMP, SMTP, DHCP, RADIUS, NTP, TELNET; IPv4 and IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware\u003c\/td\u003e\n\u003ctd\u003eRemote firmware upgrade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Sensors\u003c\/td\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCascade (Daisy-chain)\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCybersecurity\u003c\/td\u003e\n\u003ctd\u003eMeets UL 2900-1 and IEC 62443-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e1U; 44.5 x 446 x 180 mm (Eaton datasheet BR155060EN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Conductors\u003c\/td\u003e\n\u003ctd\u003ePure copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0–3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE; EN 62368-1:2014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Software Support\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat It Is Suited To\u003c\/h3\u003e\n\u003cp\u003eThe FLXTSWC20C1 suits IT equipment with IEC C14 power cords — rack servers, storage arrays, switches, routers and firewalls. Keep the total connected load within 3.7 kW and within the rating of the supply that feeds the PDU.\u003c\/p\u003e\n\u003ch3\u003eMonitoring and Software\u003c\/h3\u003e\n\u003cp\u003eManage the PDU from any web browser, or bring it into an existing monitoring or DCIM platform over SNMP (Eaton lists SNMP among the supported protocols, along with SMTP for e-mail alerts and RADIUS for central authentication). Outlet on\/off control, sequencing and whole-PDU readings are available through the same network interface.\u003c\/p\u003e\n\u003ch3\u003eInput Plug and Supply\u003c\/h3\u003e\n\u003cp\u003eThe input cord ends in an IEC C20 16A plug, which connects to an IEC C19 outlet — typically on a UPS or an upstream PDU. A standard BS 1363 wall socket cannot feed this PDU directly.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; FlexPDU G2 Switched Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cp\u003eEaton FlexPDU G2 Switched PDU with user documentation. Eaton's brochure does not list the carton contents or mounting hardware, so confirm brackets and accessories with us before ordering if they matter to your installation.\u003c\/p\u003e\n\u003ch3\u003eEaton FlexPDU G2 Switched Range — Ordering Information\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFLXTSWC20C1 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1U horizontal, 1-phase, IEC C20 16A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e8 x C13\u003c\/td\u003e\n\u003ctd\u003eP-FLXTSWC20C1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTSWC20C2\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC C20 16A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e20 x C13 + 4 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTSWC20C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTSW132C2\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC 60309 32A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003e20 x C13 + 4 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTSW132C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTSW332C4\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 32A, 22.0 kW\u003c\/td\u003e\n\u003ctd\u003e30 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTSW332C4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eBasic, Metered Input and Managed FlexPDU G2 models are also available on request.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton brochure\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/backup-power-ups-surge-it-power-distribution\/power-distribution-for-it-equipment\/eaton-flex-pdu-g2\/eaton-flexpdug2-brochure-en-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEaton FlexPDU G2 Brochure — East Asia (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton datasheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/backup-power-ups-surge-it-power-distribution\/power-distribution-for-it-equipment\/eaton-flex-pdu-g2\/flexpdug2-datasheet-br155060-emea-en-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEaton FlexPDU G2 Datasheet BR155060EN (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton product page\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/sg\/en-us\/catalog\/backup-power-ups-surge-it-power-distribution\/eaton-flex-pdu-g2.html\" target=\"_blank\" rel=\"noopener\"\u003eEaton FlexPDU G2 — Eaton Singapore\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cp\u003eNeed a PDF sent directly? Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eFLXTSWC20C1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — Eaton FLXTSWC20C1\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat is the difference between Managed, Switched and Metered Input?\u003c\/h3\u003e\n\u003cp\u003ePer Eaton, Metered Input models measure the whole PDU; Switched models such as the FLXTSWC20C1 add remote outlet on\/off switching, power sequencing and outlet groups; Managed models add per-outlet measurements on top of all of that.\u003c\/p\u003e\n\u003ch3\u003eCan I reboot a server remotely?\u003c\/h3\u003e\n\u003cp\u003eYes. Individual outlets can be switched on and off remotely through the web interface or SNMP, and you can define the power-on\/power-off order.\u003c\/p\u003e\n\u003ch3\u003eDoes it measure each outlet?\u003c\/h3\u003e\n\u003cp\u003eNo. Eaton lists full-PDU measurements (±1% accuracy) for Switched models; per-outlet measurements are a feature of the Managed models.\u003c\/p\u003e\n\u003ch3\u003eHow do I access it remotely?\u003c\/h3\u003e\n\u003cp\u003eThrough its 10\/100 Mbps Ethernet port, using a web browser or SNMP. Supported protocols include HTTPS, SSH v2, SNMP, SMTP, DHCP, RADIUS, NTP and TELNET, over IPv4 and IPv6.\u003c\/p\u003e\n\u003ch3\u003eCan I add temperature or humidity sensors?\u003c\/h3\u003e\n\u003cp\u003eYes — Eaton lists an external sensor capacity of 8 for FlexPDU G2 network models. Sensors are sold separately; ask us for a quote.\u003c\/p\u003e\n\u003ch3\u003eHow many devices can I connect?\u003c\/h3\u003e\n\u003cp\u003e8 outlets: 8 x IEC C13. C13 outlets take the common IEC C14 server\/switch cord. The total load must stay within 3.7 kW.\u003c\/p\u003e\n\u003ch3\u003eWhat supply do I need?\u003c\/h3\u003e\n\u003cp\u003eA 230V 16A IEC C19 outlet (per Eaton's Singapore price list), for example on a UPS or upstream PDU, for the C20 input plug.\u003c\/p\u003e\n\u003ch3\u003eWhat warranty do I get?\u003c\/h3\u003e\n\u003cp\u003e2 years from Eaton, supplied by SourceIT with local Singapore support and a GST invoice.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003c\/div\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":51487211061412,"sku":"P-FLXTSWC20C1","price":521.09,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/eaton-flexpdu-g2_ae6146b8-3083-468b-a493-f833c89b0947.jpg?v=1790215004","url":"https:\/\/sourceit.com.sg\/products\/eaton-flexpdu-g2-switched-1u-horizontal-rack-pdu-single-phase-16a-iec-c20-input-8x-c13-remote-outlet-switching","provider":"SourceIT ","version":"1.0","type":"link"}