{"product_id":"eaton-flexpdu-g2-metered-input-0u-vertical-rack-pdu-single-phase-63a-iec-60309-input-36x-c13-6x-c19-network","title":"Eaton FlexPDU G2 Metered Input 0U Vertical Rack PDU, Single-phase 63A IEC 60309 Input, 36x C13 + 6x C19, Network","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eEaton FlexPDU G2 Metered Input 0U Single-phase 63A Rack PDU (FLXTMI163C5, P-FLXTMI163C5) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eKnow Exactly What Your Rack Is Drawing\u003c\/h3\u003e\n\u003cp\u003eThe Eaton FlexPDU G2 FLXTMI163C5 is a Metered Input rack PDU from Eaton's second-generation FlexPDU range. It takes a single-phase 63A IEC 60309 feed and distributes up to 14.5 kW to 42 IEC outlets (36 x IEC C13 + 6 x IEC C19), while measuring the whole PDU's current, voltage, power, energy consumption and power factor with ±1% accuracy, as published by Eaton.\u003c\/p\u003e\n\u003cp\u003eFor a Singapore server room, comms cabinet or colocation rack, that means you can see real load against the feed rating before adding equipment, spot creeping consumption, and report energy use per rack instead of guessing.\u003c\/p\u003e\n\u003ch3\u003eFull Network Management, Built for Security\u003c\/h3\u003e\n\u003cp\u003eEaton's FlexPDU G2 Metered Input models include a network management module with a 10\/100 Mbps Ethernet port, full management through a web browser or SNMP, and support for HTTPS, SSH v2, SNMP, SMTP, DHCP, RADIUS, NTP and TELNET over IPv4 and IPv6. Firmware can be upgraded remotely, up to 8 external sensors can be connected, and the range supports cascade (daisy-chain) connection.\u003c\/p\u003e\n\u003cp\u003eEaton states the FlexPDU G2 network models meet the UL 2900-1 and IEC 62443-4-1 cybersecurity standards, and on 0U models the network management module is hot-swappable, so it can be replaced without interrupting power to the connected equipment.\u003c\/p\u003e\n\u003ch3\u003eBuilt for Safety in the Rack\u003c\/h3\u003e\n\u003cp\u003eEaton equips every outlet with an anti-ejection mechanism so power cords are held firmly in place, uses pure copper for the main circuit conductors, and provides additional enclosure grounding points. Models rated 32A and above are fitted with hydraulic-magnetic circuit breakers; this one has 4 x 16A single-pole breakers.\u003c\/p\u003e\n\u003ch3\u003eSupplied Locally with GST Invoice and 2-Year Warranty\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the FlexPDU G2 range in Singapore with a full GST invoice and local warranty support. Eaton's FlexPDU G2 brochure and Eaton's Singapore price list both give a 2-year warranty.\u003c\/p\u003e\n\u003cp\u003eNeed help choosing an input plug or outlet mix? Email sales@sourceit.com.sg with your rack layout and supply type.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eEaton FLXTMI163C5 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eEaton FlexPDU G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue Number\u003c\/td\u003e\n\u003ctd\u003eFLXTMI163C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMI163C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eEaton FlexPDU 2nd Generation (G2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eMetered Input rack PDU (whole-PDU metering, network management)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e0U vertical (zero-U, mounts in the rack's side channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2 years (Eaton FlexPDU G2 brochure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003e2 years, supplied by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePower\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Rating\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e230V (Eaton Singapore price list)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Power\u003c\/td\u003e\n\u003ctd\u003e14.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003ctd\u003e4 x 16A single-pole, hydraulic-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Cord Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m (Eaton brochure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eOutlets\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Outlets\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Types\u003c\/td\u003e\n\u003ctd\u003e36 x IEC C13 + 6 x IEC C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Retention\u003c\/td\u003e\n\u003ctd\u003eAnti-ejection mechanism on all outlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eMetering \u0026amp; Network\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eFull PDU measurements: current, voltage, power, energy consumption, power factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePer-outlet Metering \/ Switching\u003c\/td\u003e\n\u003ctd\u003eNo (available on FlexPDU G2 Managed \/ Switched models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps Ethernet; web and SNMP management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eHTTPS, SSH v2, SNMP, SMTP, DHCP, RADIUS, NTP, TELNET; IPv4 and IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware\u003c\/td\u003e\n\u003ctd\u003eRemote firmware upgrade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Sensors\u003c\/td\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCascade (Daisy-chain)\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Module\u003c\/td\u003e\n\u003ctd\u003eHot-swappable (0U models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCybersecurity\u003c\/td\u003e\n\u003ctd\u003eMeets UL 2900-1 and IEC 62443-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Conductors\u003c\/td\u003e\n\u003ctd\u003ePure copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0–3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE; EN 62368-1:2014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Software Support\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat It Is Suited To\u003c\/h3\u003e\n\u003cp\u003eThe FLXTMI163C5 suits IT equipment with IEC C14 or C20 power cords — rack servers, storage arrays, switches, routers and firewalls. Keep the total connected load within 14.5 kW and within the rating of the supply that feeds the PDU.\u003c\/p\u003e\n\u003ch3\u003eMonitoring and Software\u003c\/h3\u003e\n\u003cp\u003eManage the PDU from any web browser, or bring it into an existing monitoring or DCIM platform over SNMP (Eaton lists SNMP among the supported protocols, along with SMTP for e-mail alerts and RADIUS for central authentication). Metering is for the whole PDU; for per-outlet measurement or remote outlet switching, choose a FlexPDU G2 Managed or Switched model.\u003c\/p\u003e\n\u003ch3\u003eInput Plug and Supply\u003c\/h3\u003e\n\u003cp\u003eThe input is an IEC 60309 63A single-phase industrial plug. Your rack feed needs the matching IEC 60309 socket, installed by a licensed electrician; a standard BS 1363 wall socket cannot feed this PDU.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; FlexPDU G2 Metered Input Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cp\u003eEaton FlexPDU G2 Metered Input PDU with user documentation. Eaton's brochure does not list the carton contents or mounting hardware, so confirm brackets and accessories with us before ordering if they matter to your installation.\u003c\/p\u003e\n\u003ch3\u003eEaton FlexPDU G2 Metered Input Range — Ordering Information\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMIC14C1\u003c\/td\u003e\n\u003ctd\u003e1U, 1-phase, IEC C14 10A, 2.3 kW\u003c\/td\u003e\n\u003ctd\u003e8 x C13\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMIC14C1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMIC20C1\u003c\/td\u003e\n\u003ctd\u003e1U, 1-phase, IEC C20 16A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e8 x C13\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMIC20C1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMIC20C2\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC C20 16A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e20 x C13 + 4 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMIC20C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMI116C2\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC 60309 16A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e20 x C13 + 4 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMI116C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMI132C2\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC 60309 32A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003e20 x C13 + 4 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMI132C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFLXTMI163C5 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC 60309 63A, 14.5 kW\u003c\/td\u003e\n\u003ctd\u003e36 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMI163C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMI316C3\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 16A, 11.0 kW\u003c\/td\u003e\n\u003ctd\u003e18 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMI316C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMI316C5\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 16A, 11.0 kW\u003c\/td\u003e\n\u003ctd\u003e36 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMI316C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMI332C3\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 32A, 22.0 kW\u003c\/td\u003e\n\u003ctd\u003e18 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMI332C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMI332C4\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 32A, 22.0 kW\u003c\/td\u003e\n\u003ctd\u003e30 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMI332C4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMI332C5\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 32A, 22.0 kW\u003c\/td\u003e\n\u003ctd\u003e36 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMI332C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMI363C5\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 63A, 43.5 kW\u003c\/td\u003e\n\u003ctd\u003e36 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMI363C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eBasic, Switched and Managed FlexPDU G2 models are also available on request.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton brochure\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/backup-power-ups-surge-it-power-distribution\/power-distribution-for-it-equipment\/eaton-flex-pdu-g2\/eaton-flexpdug2-brochure-en-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEaton FlexPDU G2 Brochure — East Asia (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton datasheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/backup-power-ups-surge-it-power-distribution\/power-distribution-for-it-equipment\/eaton-flex-pdu-g2\/flexpdug2-datasheet-br155060-emea-en-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEaton FlexPDU G2 Datasheet BR155060EN (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton product page\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/sg\/en-us\/catalog\/backup-power-ups-surge-it-power-distribution\/eaton-flex-pdu-g2.html\" target=\"_blank\" rel=\"noopener\"\u003eEaton FlexPDU G2 — Eaton Singapore\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eNeed a PDF sent directly? Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eFLXTMI163C5\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — Eaton FLXTMI163C5\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat does the FLXTMI163C5 measure?\u003c\/h3\u003e\n\u003cp\u003eWhole-PDU current, voltage, power, energy consumption and power factor, with ±1% accuracy per Eaton. It does not meter or switch individual outlets — that needs a FlexPDU G2 Managed (per-outlet metering) or Switched (outlet on\/off) model.\u003c\/p\u003e\n\u003ch3\u003eHow do I access it remotely?\u003c\/h3\u003e\n\u003cp\u003eThrough its 10\/100 Mbps Ethernet port, using a web browser or SNMP. Supported protocols include HTTPS, SSH v2, SNMP, SMTP, DHCP, RADIUS, NTP and TELNET, over IPv4 and IPv6.\u003c\/p\u003e\n\u003ch3\u003eCan I add temperature or humidity sensors?\u003c\/h3\u003e\n\u003cp\u003eYes — Eaton lists an external sensor capacity of 8 for FlexPDU G2 network models. Sensors are sold separately; ask us for a quote.\u003c\/p\u003e\n\u003ch3\u003eHow many devices can I connect?\u003c\/h3\u003e\n\u003cp\u003e42 outlets: 36 x IEC C13 + 6 x IEC C19. C13 outlets take the common IEC C14 server\/switch cord; C19 outlets take C20 cords used by higher-power equipment. The total load must stay within 14.5 kW.\u003c\/p\u003e\n\u003ch3\u003eWhat supply do I need?\u003c\/h3\u003e\n\u003cp\u003eA single-phase 63A feed matching the IEC 60309 input. An IEC 60309 socket must be installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eWhat warranty do I get?\u003c\/h3\u003e\n\u003cp\u003e2 years from Eaton, supplied by SourceIT with local Singapore support and a GST invoice.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003c\/div\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":51486862311588,"sku":"P-FLXTMI163C5","price":823.58,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/eaton-flexpdu-g2_5e0fe1be-5d92-4f25-ad9d-cf8c35c27285.jpg?v=1790214976","url":"https:\/\/sourceit.com.sg\/products\/eaton-flexpdu-g2-metered-input-0u-vertical-rack-pdu-single-phase-63a-iec-60309-input-36x-c13-6x-c19-network","provider":"SourceIT ","version":"1.0","type":"link"}