{"product_id":"eaton-flexpdu-g2-managed-0u-vertical-rack-pdu-single-phase-63a-iec-60309-input-36x-c13-6x-c19-per-outlet-metering-switching","title":"Eaton FlexPDU G2 Managed 0U Vertical Rack PDU, Single-phase 63A IEC 60309 Input, 36x C13 + 6x C19, Per-Outlet Metering \u0026 Switching","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eEaton FlexPDU G2 Managed 0U Single-phase 63A Rack PDU (FLXTMA163C5, P-FLXTMA163C5) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eControl and Measure Every Outlet\u003c\/h3\u003e\n\u003cp\u003eThe Eaton FlexPDU G2 FLXTMA163C5 is a Managed rack PDU from Eaton's second-generation FlexPDU range. It takes a single-phase 63A IEC 60309 feed and distributes up to 14.5 kW to 42 IEC outlets (36 x IEC C13 + 6 x IEC C19). Eaton's Managed models combine per-outlet measurements with remote on\/off outlet switching, user-defined power-on\/power-off sequencing and grouped outlet control, on top of whole-PDU metering with ±1% accuracy.\u003c\/p\u003e\n\u003cp\u003eFor a Singapore data centre, colocation suite or server room, that means you can see which device is drawing what, power-cycle a hung server remotely instead of sending someone on site, and stagger start-up after an outage so the feed is not overloaded.\u003c\/p\u003e\n\u003ch3\u003eFull Network Management, Built for Security\u003c\/h3\u003e\n\u003cp\u003eEaton's FlexPDU G2 Managed models include a hot-swappable network management module with a 10\/100 Mbps Ethernet port, full management through a web browser or SNMP, and support for HTTPS, SSH v2, SNMP, SMTP, DHCP, RADIUS, NTP and TELNET over IPv4 and IPv6. Firmware can be upgraded remotely, up to 8 external sensors can be connected, and the range supports cascade (daisy-chain) connection.\u003c\/p\u003e\n\u003cp\u003eEaton states the FlexPDU G2 network models meet the UL 2900-1 and IEC 62443-4-1 cybersecurity standards, and on 0U models the network management module can be replaced without interrupting power to the connected equipment.\u003c\/p\u003e\n\u003ch3\u003eBuilt for Safety in the Rack\u003c\/h3\u003e\n\u003cp\u003eEaton equips every outlet with an anti-ejection mechanism so power cords are held firmly in place, uses pure copper for the main circuit conductors, and provides additional enclosure grounding points. Models rated 32A and above are fitted with hydraulic-magnetic circuit breakers; this one has 4 x 16A single-pole breakers.\u003c\/p\u003e\n\u003ch3\u003eSupplied Locally with GST Invoice and 2-Year Warranty\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the FlexPDU G2 range in Singapore with a full GST invoice and local warranty support. Eaton's FlexPDU G2 brochure and Eaton's Singapore price list both give a 2-year warranty.\u003c\/p\u003e\n\u003cp\u003eNeed help choosing an input plug or outlet mix? Email sales@sourceit.com.sg with your rack layout and supply type.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eEaton FLXTMA163C5 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eEaton FlexPDU G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue Number\u003c\/td\u003e\n\u003ctd\u003eFLXTMA163C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMA163C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eEaton FlexPDU 2nd Generation (G2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eManaged rack PDU (per-outlet metering and switching, network management)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e0U vertical (zero-U, mounts in the rack's side channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2 years (Eaton FlexPDU G2 brochure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003e2 years, supplied by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePower\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Rating\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e230V (Eaton Singapore price list)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Power\u003c\/td\u003e\n\u003ctd\u003e14.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003ctd\u003e4 x 16A single-pole, hydraulic-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Cord Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m (Eaton brochure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eOutlets\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Outlets\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Types\u003c\/td\u003e\n\u003ctd\u003e36 x IEC C13 + 6 x IEC C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Retention\u003c\/td\u003e\n\u003ctd\u003eAnti-ejection mechanism on all outlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eMetering \u0026amp; Network\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003ePer-outlet measurements plus full PDU measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhole-PDU Measurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd\u003eRemote on\/off switching of individual outlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Sequencing\u003c\/td\u003e\n\u003ctd\u003eUser-defined power-on \/ power-off sequence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Groups\u003c\/td\u003e\n\u003ctd\u003eGrouped outlet control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps Ethernet; web and SNMP management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eHTTPS, SSH v2, SNMP, SMTP, DHCP, RADIUS, NTP, TELNET; IPv4 and IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware\u003c\/td\u003e\n\u003ctd\u003eRemote firmware upgrade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Sensors\u003c\/td\u003e\n\u003ctd\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCascade (Daisy-chain)\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Module\u003c\/td\u003e\n\u003ctd\u003eHot-swappable (0U models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCybersecurity\u003c\/td\u003e\n\u003ctd\u003eMeets UL 2900-1 and IEC 62443-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Conductors\u003c\/td\u003e\n\u003ctd\u003ePure copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0–3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE; EN 62368-1:2014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Software Support\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat It Is Suited To\u003c\/h3\u003e\n\u003cp\u003eThe FLXTMA163C5 suits IT equipment with IEC C14 or C20 power cords — rack servers, storage arrays, switches, routers and firewalls. Keep the total connected load within 14.5 kW and within the rating of the supply that feeds the PDU.\u003c\/p\u003e\n\u003ch3\u003eMonitoring and Software\u003c\/h3\u003e\n\u003cp\u003eManage the PDU from any web browser, or bring it into an existing monitoring or DCIM platform over SNMP (Eaton lists SNMP among the supported protocols, along with SMTP for e-mail alerts and RADIUS for central authentication). Outlet-level readings and outlet on\/off control are available through the same network interface.\u003c\/p\u003e\n\u003ch3\u003eInput Plug and Supply\u003c\/h3\u003e\n\u003cp\u003eThe input is an IEC 60309 63A single-phase industrial plug. Your rack feed needs the matching IEC 60309 socket, installed by a licensed electrician; a standard BS 1363 wall socket cannot feed this PDU.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; FlexPDU G2 Managed Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cp\u003eEaton FlexPDU G2 Managed PDU with user documentation. Eaton's brochure does not list the carton contents or mounting hardware, so confirm brackets and accessories with us before ordering if they matter to your installation.\u003c\/p\u003e\n\u003ch3\u003eEaton FlexPDU G2 Managed Range — Ordering Information\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMA116C2\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC 60309 16A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e20 x C13 + 4 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMA116C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMA132C2\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC 60309 32A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003e20 x C13 + 4 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMA132C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFLXTMA163C5 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC 60309 63A, 14.5 kW\u003c\/td\u003e\n\u003ctd\u003e36 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMA163C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMA316C3\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 16A, 11.0 kW\u003c\/td\u003e\n\u003ctd\u003e18 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMA316C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMA332C3\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 32A, 22.0 kW\u003c\/td\u003e\n\u003ctd\u003e18 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMA332C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMA332C5\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 32A, 22.0 kW\u003c\/td\u003e\n\u003ctd\u003e36 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMA332C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTMA363C5\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 63A, 43.5 kW\u003c\/td\u003e\n\u003ctd\u003e36 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTMA363C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eBasic, Metered Input and Switched FlexPDU G2 models are also available on request.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton brochure\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/backup-power-ups-surge-it-power-distribution\/power-distribution-for-it-equipment\/eaton-flex-pdu-g2\/eaton-flexpdug2-brochure-en-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEaton FlexPDU G2 Brochure — East Asia (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton datasheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/backup-power-ups-surge-it-power-distribution\/power-distribution-for-it-equipment\/eaton-flex-pdu-g2\/flexpdug2-datasheet-br155060-emea-en-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEaton FlexPDU G2 Datasheet BR155060EN (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton product page\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/sg\/en-us\/catalog\/backup-power-ups-surge-it-power-distribution\/eaton-flex-pdu-g2.html\" target=\"_blank\" rel=\"noopener\"\u003eEaton FlexPDU G2 — Eaton Singapore\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eNeed a PDF sent directly? Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eFLXTMA163C5\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — Eaton FLXTMA163C5\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat is the difference between Managed, Switched and Metered Input?\u003c\/h3\u003e\n\u003cp\u003ePer Eaton, Metered Input models measure the whole PDU; Switched models add remote outlet on\/off switching, power sequencing and outlet groups; Managed models such as the FLXTMA163C5 add per-outlet measurements on top of all of that.\u003c\/p\u003e\n\u003ch3\u003eCan I reboot a server remotely?\u003c\/h3\u003e\n\u003cp\u003eYes. Individual outlets can be switched on and off remotely through the web interface or SNMP, and you can define the power-on\/power-off order.\u003c\/p\u003e\n\u003ch3\u003eHow do I access it remotely?\u003c\/h3\u003e\n\u003cp\u003eThrough its 10\/100 Mbps Ethernet port, using a web browser or SNMP. Supported protocols include HTTPS, SSH v2, SNMP, SMTP, DHCP, RADIUS, NTP and TELNET, over IPv4 and IPv6.\u003c\/p\u003e\n\u003ch3\u003eCan I add temperature or humidity sensors?\u003c\/h3\u003e\n\u003cp\u003eYes — Eaton lists an external sensor capacity of 8 for FlexPDU G2 network models. Sensors are sold separately; ask us for a quote.\u003c\/p\u003e\n\u003ch3\u003eHow many devices can I connect?\u003c\/h3\u003e\n\u003cp\u003e42 outlets: 36 x IEC C13 + 6 x IEC C19. C13 outlets take the common IEC C14 server\/switch cord; C19 outlets take C20 cords used by higher-power equipment. The total load must stay within 14.5 kW.\u003c\/p\u003e\n\u003ch3\u003eWhat supply do I need?\u003c\/h3\u003e\n\u003cp\u003eA single-phase 63A feed matching the IEC 60309 input (230V per Eaton's Singapore price list). An IEC 60309 socket must be installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eWhat warranty do I get?\u003c\/h3\u003e\n\u003cp\u003e2 years from Eaton, supplied by SourceIT with local Singapore support and a GST invoice.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003c\/div\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":51487066259620,"sku":"P-FLXTMA163C5","price":1850.3,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/eaton-flexpdu-g2_3203fba0-8f2d-4a48-a4c0-a2e024e68f37.jpg?v=1790215003","url":"https:\/\/sourceit.com.sg\/products\/eaton-flexpdu-g2-managed-0u-vertical-rack-pdu-single-phase-63a-iec-60309-input-36x-c13-6x-c19-per-outlet-metering-switching","provider":"SourceIT ","version":"1.0","type":"link"}