{"product_id":"eaton-flexpdu-g2-basic-1u-rack-pdu-single-phase-16a-iec-c20-input-8x-iec-c13","title":"Eaton FlexPDU G2 Basic 1U Rack PDU, Single-phase 16A IEC C20 Input, 8x IEC C13","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eEaton FlexPDU G2 Basic 1U Single-phase 16A Rack PDU (FLXTBAC20C1, P-FLXTBAC20C1) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eSimple, Dependable Rack Power Distribution\u003c\/h3\u003e\n\u003cp\u003eThe Eaton FlexPDU G2 FLXTBAC20C1 is a Basic (non-metered, non-networked) rack PDU from Eaton's second-generation FlexPDU range. It takes an IEC C20 16A single-phase feed and distributes up to 3.7 kW to 8 IEC outlets (8 x IEC C13), which makes it a straightforward way to power servers, storage and network switches in a Singapore server room, comms cabinet or colocation rack.\u003c\/p\u003e\n\u003cp\u003eThe 1U horizontal chassis fits a standard 19-inch rack and suits smaller cabinets or network racks where a short row of outlets is all that is needed.\u003c\/p\u003e\n\u003ch3\u003eBuilt for Safety in the Rack\u003c\/h3\u003e\n\u003cp\u003eEaton equips every outlet with an anti-ejection mechanism so power cords are held firmly in place, uses pure copper for the main circuit conductors, and provides additional enclosure grounding points.\u003c\/p\u003e\n\u003ch3\u003eSupplied Locally with GST Invoice and 2-Year Warranty\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the FlexPDU G2 range in Singapore with a full GST invoice and local warranty support. Eaton's FlexPDU G2 brochure and Eaton's Singapore price list both give a 2-year warranty.\u003c\/p\u003e\n\u003cp\u003eNeed help choosing an input plug or outlet mix? Email sales@sourceit.com.sg with your rack layout and supply type.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eEaton FLXTBAC20C1 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eEaton FlexPDU G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue Number\u003c\/td\u003e\n\u003ctd\u003eFLXTBAC20C1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eP-FLXTBAC20C1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eEaton FlexPDU 2nd Generation (G2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eBasic rack PDU (no metering, no network interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e1U horizontal (19-inch rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2 years (Eaton FlexPDU G2 brochure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003e2 years, supplied by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePower\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Rating\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e230V (Eaton Singapore price list)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Power\u003c\/td\u003e\n\u003ctd\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003ctd\u003eNone (Eaton lists no breaker for this model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Cord Length\u003c\/td\u003e\n\u003ctd\u003e2.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eOutlets\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Outlets\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Types\u003c\/td\u003e\n\u003ctd\u003e8 x IEC C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Retention\u003c\/td\u003e\n\u003ctd\u003eAnti-ejection mechanism on all outlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Conductors\u003c\/td\u003e\n\u003ctd\u003ePure copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0–3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE; EN 62368-1:2014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Software Support\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat It Is Suited To\u003c\/h3\u003e\n\u003cp\u003eThe FLXTBAC20C1 suits IT equipment with IEC C14 power cords — rack servers, storage arrays, switches, routers and firewalls. Keep the total connected load within 3.7 kW and within the rating of the supply that feeds the PDU.\u003c\/p\u003e\n\u003ch3\u003eMonitoring and Software\u003c\/h3\u003e\n\u003cp\u003eThis is a Basic model: it has no display, no metering and no network port, so there is no software to install. If you need to see current draw or manage outlets remotely, the FlexPDU G2 range also includes Metered Input, Switched and Managed models — ask us for the equivalent part.\u003c\/p\u003e\n\u003ch3\u003eInput Plug and Supply\u003c\/h3\u003e\n\u003cp\u003eThe input is an IEC C20 inlet plug (16A). It connects to a UPS output or another PDU with a matching IEC outlet (C19), not directly to a BS 1363 wall socket.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; FlexPDU G2 Basic Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cp\u003eEaton FlexPDU G2 Basic PDU with user documentation. Eaton's brochure does not list the carton contents or mounting hardware, so confirm brackets and accessories with us before ordering if they matter to your installation.\u003c\/p\u003e\n\u003ch3\u003eEaton FlexPDU G2 Basic Range — Ordering Information\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTBAC14C1\u003c\/td\u003e\n\u003ctd\u003e1U, 1-phase, IEC C14 10A, 2.3 kW\u003c\/td\u003e\n\u003ctd\u003e8 x C13\u003c\/td\u003e\n\u003ctd\u003eP-FLXTBAC14C1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFLXTBAC20C1 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1U, 1-phase, IEC C20 16A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e8 x C13\u003c\/td\u003e\n\u003ctd\u003eP-FLXTBAC20C1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTBAC20C2\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC C20 16A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e20 x C13 + 4 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTBAC20C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTBA116C2\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC 60309 16A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e20 x C13 + 4 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTBA116C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTBA132C2\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC 60309 32A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003e20 x C13 + 4 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTBA132C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTBA163C5\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, IEC 60309 63A, 14.5 kW\u003c\/td\u003e\n\u003ctd\u003e36 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTBA163C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTBAT13C2\u003c\/td\u003e\n\u003ctd\u003e0U, 1-phase, 32A junction box, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003e20 x C13 + 4 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTBAT13C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTBA316C3\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 16A, 11.0 kW\u003c\/td\u003e\n\u003ctd\u003e18 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTBA316C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTBA316C5\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 16A, 11.0 kW\u003c\/td\u003e\n\u003ctd\u003e36 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTBA316C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTBA332C3\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 32A, 22.0 kW\u003c\/td\u003e\n\u003ctd\u003e18 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTBA332C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTBA332C4\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 32A, 22.0 kW\u003c\/td\u003e\n\u003ctd\u003e30 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTBA332C4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTBA332C5\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 32A, 22.0 kW\u003c\/td\u003e\n\u003ctd\u003e36 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTBA332C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTBAT33C3\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, 32A junction box, 22.0 kW\u003c\/td\u003e\n\u003ctd\u003e18 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTBAT33C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLXTBA363C5\u003c\/td\u003e\n\u003ctd\u003e0U, 3-phase, IEC 60309 63A, 43.5 kW\u003c\/td\u003e\n\u003ctd\u003e36 x C13 + 6 x C19\u003c\/td\u003e\n\u003ctd\u003eP-FLXTBA363C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eMetered Input, Switched and Managed FlexPDU G2 models are also available on request.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton brochure\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/backup-power-ups-surge-it-power-distribution\/power-distribution-for-it-equipment\/eaton-flex-pdu-g2\/eaton-flexpdug2-brochure-en-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEaton FlexPDU G2 Brochure — East Asia (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton datasheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/backup-power-ups-surge-it-power-distribution\/power-distribution-for-it-equipment\/eaton-flex-pdu-g2\/flexpdug2-datasheet-br155060-emea-en-us.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEaton FlexPDU G2 Datasheet BR155060EN (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton product page\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.eaton.com\/sg\/en-us\/catalog\/backup-power-ups-surge-it-power-distribution\/eaton-flex-pdu-g2.html\" target=\"_blank\" rel=\"noopener\"\u003eEaton FlexPDU G2 — Eaton Singapore\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eNeed a PDF sent directly? Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eFLXTBAC20C1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — Eaton FLXTBAC20C1\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eDoes the FLXTBAC20C1 show power consumption?\u003c\/h3\u003e\n\u003cp\u003eNo. It is a Basic PDU with no meter or network port. Choose a FlexPDU G2 Metered Input model to see the load, or a Switched \/ Managed model for per-outlet control.\u003c\/p\u003e\n\u003ch3\u003eHow many devices can I connect?\u003c\/h3\u003e\n\u003cp\u003e8 x IEC C13 outlets, which take the common IEC C14 cord used by servers, switches and storage. The total load must stay within 3.7 kW.\u003c\/p\u003e\n\u003ch3\u003eWhat supply do I need?\u003c\/h3\u003e\n\u003cp\u003eA single-phase 16A feed matching the IEC C20 input. It is designed to plug into a UPS or PDU outlet with the matching IEC connector.\u003c\/p\u003e\n\u003ch3\u003eWhat warranty do I get?\u003c\/h3\u003e\n\u003cp\u003e2 years from Eaton, supplied by SourceIT with local Singapore support and a GST invoice.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\n\u003c\/div\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":51486727176356,"sku":"P-FLXTBAC20C1","price":79.49,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/eaton-flexpdu-g2_19863a80-7d70-4dca-9927-b3509b68063b.jpg?v=1790214923","url":"https:\/\/sourceit.com.sg\/products\/eaton-flexpdu-g2-basic-1u-rack-pdu-single-phase-16a-iec-c20-input-8x-iec-c13","provider":"SourceIT ","version":"1.0","type":"link"}