{"product_id":"apc-smart-ups-srt-10000va-10000w-tower-230v-on-line-double-conversion-srt10kxli","title":"APC Smart-UPS SRT 10000VA 10000W Tower 230V On-Line Double Conversion","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Smart-UPS SRT 10000VA 230V (SRT10KXLI) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003e10 kVA \/ 10 kW Double-Conversion On-Line Protection in a Floor-Standing Tower\u003c\/h3\u003e\n\u003cp\u003eThe APC Smart-UPS SRT 10000VA (SRT10KXLI) is the top of the SRT tower range: an on-line, double-conversion UPS that rectifies incoming mains to DC and regenerates it as a clean sine wave, so the load runs from the inverter continuously rather than being switched over when the supply fails. Output harmonic distortion is rated at less than 2% and an internal bypass (automatic and manual) is fitted. At 10 kW this is protecting a full production rack, and on Singapore's 230V \/ 50Hz supply the everyday risk is the PUB grid dips and momentary interruptions of the storm season — each one enough to reset a hypervisor host.\u003c\/p\u003e\n\u003ch3\u003eUnity Power Factor: 10,000 VA and a Full 10,000 W of Usable Output\u003c\/h3\u003e\n\u003cp\u003eThe SRT10KXLI delivers 10,000 W from its 10,000 VA rating, so there is no watt derating to design around. Nominal output is 230 V AC single phase, configurable to 220 V or 240 V, at 50\/60 Hz ±3 Hz synchronised to mains, on (6) IEC 60320 C13 and (4) IEC 60320 C19 outlets with (3) IEC jumpers, plus a hard-wire 3-wire output. A 3:1 crest factor gives headroom for the inrush of switch-mode server power supplies. Size on watts: total the real power draw of everything you intend to protect and keep it comfortably under 10,000 W.\u003c\/p\u003e\n\u003ch3\u003eSingle-Phase or Three-Phase Input — Both Hard Wired\u003c\/h3\u003e\n\u003cp\u003eThe SRT10KXLI accepts either a 230 V AC single-phase supply (one 3-wire hardwire, 1P + N + E) or a 380 \/ 400 \/ 415 V AC three-phase supply (one 5-wire hardwire, 3P + N + E), at 40–70 Hz auto-sensing. The input window is adjustable down to 100–275 V at half load on single phase, or 173–476 V on three phase. There is no plug — book a licensed electrician and confirm the supply and breaker rating with building management before the delivery date. On a three-phase feed the output remains single phase.\u003c\/p\u003e\n\u003ch3\u003eScalable Runtime with SRT192BP2 Battery Packs\u003c\/h3\u003e\n\u003cp\u003eThe battery system is sealed lead-acid on a ±192 V split bus referenced to neutral, with two \u003ca href=\"\/products\/apc-replacement-battery-cartridge-apcrbc140\" target=\"_blank\" rel=\"noopener\"\u003eAPCRBC140\u003c\/a\u003e cartridges, an 876 W rated charger, a 1.5-hour typical recharge time and an expected service life of three to five years. Schneider's runtime estimator on the Singapore product page shows 3 minutes 45 seconds at the full 10,000 W load — a ride-through figure that lengthens considerably at partial load. For defined autonomy the SRT10KXLI accepts up to ten \u003ca href=\"\/products\/apc-smart-ups-srt-192v-8kva-and-10kva-battery-pack-srt192bp2\" target=\"_blank\" rel=\"noopener\"\u003eSRT192BP2\u003c\/a\u003e external battery packs. Ambient temperature is the main determinant of battery life, so keep the room cool; the unit is rated for 0–40°C at 0–95% non-condensing humidity.\u003c\/p\u003e\n\u003ch3\u003eNetwork Management Card 3 Included, Rail Kit Sold Separately, Local Singapore Supply\u003c\/h3\u003e\n\u003cp\u003eA Network Management Card 3 with environmental monitoring is pre-installed and one SmartSlot remains free, so SNMP, HTTPS and EcoStruxure-ready monitoring are available out of the box — Schneider's Singapore listing includes a one-year Secure Network Management Card subscription — and you can still add an \u003ca href=\"\/products\/apc-dry-contact-i-o-smartslot-card-ap9613\" target=\"_blank\" rel=\"noopener\"\u003eAP9613\u003c\/a\u003e Dry Contact I\/O card later. The tower chassis measures 432 mm (H) x 263 mm (W) x 715 mm (D) and ships \u003cstrong\u003ewithout a rail kit\u003c\/strong\u003e; Schneider describes it as rack\/tower convertible with the SRTRK2 or SRTRK3 sold separately, and the \u003ca href=\"\/products\/apc-smart-ups-srt-10000va-rm-230v-srt10krmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT10KRMXLI\u003c\/a\u003e is the 6U rackmount build with rails in the box. Net weight is 111.82 kg; acoustic noise is 55 dBA and thermal dissipation 1,947 BTU\/hr. SourceIT supplies it from Singapore with a GST invoice and local warranty support.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRT10KXLI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRT10KXLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS On-Line, 10kVA\/10kW, Tower, 230V\/400V, 6x C13+4x C19 IEC outlets, Network Card+SmartSlot, Extended runtime, W\/O rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPS Type \/ Topology\u003c\/td\u003e\n\u003ctd\u003eOn-line, double conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower (rack\/tower convertible with optional rail kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e10,000 VA \/ 10,000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 1 phase (also configurable 220 V \/ 240 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±3 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Harmonic Distortion\u003c\/td\u003e\n\u003ctd\u003eLess than 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor\u003c\/td\u003e\n\u003ctd\u003e3 : 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBypass\u003c\/td\u003e\n\u003ctd\u003eInternal bypass (automatic and manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003e(6) IEC 60320 C13, (3) IEC jumpers, (4) IEC 60320 C19, and (1) hard wire 3-wire (H N + E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e480 Joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC 1 phase, or 380 \/ 400 \/ 415 V AC 3 phase (also 220 V \/ 240 V single phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e100–275 V adjustable at half load (1 phase); 173–476 V adjustable at half load (3 phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003e(1) hard wire 3-wire (1P + N + E) or (1) hard wire 5-wire (3P + N + E) — a fixed electrical connection, not a plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed lead-acid (VRLA), internal, included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e±192 V (split battery referenced to neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charger Power\u003c\/td\u003e\n\u003ctd\u003e876 W rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/apc-replacement-battery-cartridge-apcrbc140\" target=\"_blank\" rel=\"noopener\"\u003eAPCRBC140\u003c\/a\u003e — quantity 2 per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e1.5 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Full Load (10,000 W)\u003c\/td\u003e\n\u003ctd\u003e3 minutes 45 seconds (Schneider Electric Singapore runtime estimator)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Battery Life\u003c\/td\u003e\n\u003ctd\u003e3 to 5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible External Battery Packs\u003c\/td\u003e\n\u003ctd\u003eSRT192BP2 — up to 10 packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management Card\u003c\/td\u003e\n\u003ctd\u003eIncluded — Network Management Card 3 with environmental monitoring, pre-installed; the Schneider Singapore listing includes a 1-year Secure Network Management Card subscription\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmartSlot\u003c\/td\u003e\n\u003ctd\u003e1 free slot in addition to the card already fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections\u003c\/td\u003e\n\u003ctd\u003eSerial port, USB port (USB cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Panel\u003c\/td\u003e\n\u003ctd\u003eMulti-function LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarms\u003c\/td\u003e\n\u003ctd\u003eAudible and visible alarms, prioritised by severity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003eSupplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003eTower unit — 6U when converted with the optional rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e432 mm (H) x 263 mm (W) x 715 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e111.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e126.82 kg (packaged 46.1 x 100 x 60 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRail Kit\u003c\/td\u003e\n\u003ctd\u003eNot included — Schneider lists SRTRK2 or SRTRK3 as sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcoustic Level\u003c\/td\u003e\n\u003ctd\u003e55 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e1,947 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 3,048 m (0 to 10,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-15 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards \u0026amp; Marks\u003c\/td\u003e\n\u003ctd\u003eCE, EAC, IRAM, RCM, VDE; EN\/IEC 62040-1:2019\/A11:2021, EN\/IEC 62040-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e3 years repair or replace excluding the battery, and 2 years for the battery (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003e3 years on the UPS and 2 years on the battery, supplied and supported by SourceIT Pte Ltd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug in.\u003c\/strong\u003e (6) IEC 60320 C13, (4) IEC 60320 C19 and (3) IEC jumpers, plus a hard-wire 3-wire output for a downstream distribution board or rack PDU, all battery-backed. Keep the total real power draw (watts) below the 10,000 W rating — runtime falls sharply as load rises.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRuntime depends on load.\u003c\/strong\u003e Schneider's runtime estimator shows 3 minutes 45 seconds at the full 10,000 W load on the internal batteries. Runtime is not linear — halving the load more than doubles the time on battery — so ask SourceIT for a calculation against your measured watts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtended runtime.\u003c\/strong\u003e Connect up to ten \u003ca href=\"\/products\/apc-smart-ups-srt-192v-8kva-and-10kva-battery-pack-srt192bp2\" target=\"_blank\" rel=\"noopener\"\u003eSRT192BP2\u003c\/a\u003e external battery packs on the ±192 V bus. Recharge time increases with each pack added, and each pack has a keyed connector that only fits its corresponding UPS. The rackmount \u003ca href=\"\/products\/apc-smart-ups-srt-192v-8-and-10kva-rm-battery-pack-srt192rmbp2\" target=\"_blank\" rel=\"noopener\"\u003eSRT192RMBP2\u003c\/a\u003e is the pack for the rackmount \u003ca href=\"\/products\/apc-smart-ups-srt-10000va-rm-230v-srt10krmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT10KRMXLI\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e This is the tower SKU: 432 mm (H) x 263 mm (W) x 715 mm (D), shipped \u003cstrong\u003ewithout a rail kit\u003c\/strong\u003e. Schneider lists SRTRK2 or SRTRK3 as the rail kit sold separately; converted, the chassis occupies 6U. At 111.82 kg, check the rack's static load rating and the delivery route before the unit arrives. If you know it is going into a cabinet, the \u003ca href=\"\/products\/apc-smart-ups-srt-10000va-rm-230v-srt10krmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT10KRMXLI\u003c\/a\u003e is the 6U rackmount build with rails included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput and circuit — read this before ordering.\u003c\/strong\u003e The SRT10KXLI is \u003cstrong\u003ehard wired\u003c\/strong\u003e, with no input plug: one 3-wire hardwire (1P + N + E) for single phase, or one 5-wire hardwire (3P + N + E) for three phase, at 40–70 Hz auto-sensing. A licensed electrician must terminate it onto a suitably rated dedicated circuit — confirm the supply, conductor sizing and breaker rating with building management before delivery, using the operation manual linked below. This is the most common cause of a delayed SRT installation in Singapore.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork management.\u003c\/strong\u003e A Network Management Card 3 with environmental monitoring is pre-installed, so SNMP, HTTPS and email alerting are available out of the box and PowerChute Network Shutdown can close down multiple servers gracefully. One SmartSlot remains free for an \u003ca href=\"\/products\/apc-dry-contact-i-o-smartslot-card-ap9613\" target=\"_blank\" rel=\"noopener\"\u003eAP9613\u003c\/a\u003e Dry Contact I\/O card, and the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\" target=\"_blank\" rel=\"noopener\"\u003eAP9335TH\u003c\/a\u003e sensor adds humidity readings to the card's environmental inputs.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Smart-UPS SRT Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eIn the box (Schneider package contents):\u003c\/strong\u003e CD with software, documentation CD, installation guide, temperature probe, USB cable, warranty card, and a Web\/SNMP management card.\u003c\/p\u003e\n\u003ch4\u003eSmart-UPS SRT 5–10 kVA range at SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRT5KXLI\u003c\/td\u003e\n\u003ctd\u003e5,000 VA \/ 4,500 W · Tower · rail kit not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-5000va-rm-230v-srt5krmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT5KRMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5,000 VA \/ 4,500 W · Rackmount 3U · rail kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-6000va-230v-srt6kxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT6KXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6,000 VA \/ 6,000 W · Tower · rail kit not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-6000va-rm-230v-srt6krmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT6KRMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6,000 VA \/ 6,000 W · Rackmount 4U · rail kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-8000va-230v-srt8kxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT8KXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e8,000 VA \/ 8,000 W · Tower · rail kit not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-8000va-rm-230v-srt8krmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT8KRMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e8,000 VA \/ 8,000 W · Rackmount 6U · rail kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSRT10KXLI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10,000 VA \/ 10,000 W · Tower · rail kit not included\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-10000va-rm-230v-srt10krmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT10KRMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 VA \/ 10,000 W · Rackmount 6U · rail kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMatching SRT external battery packs\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-192v-8kva-and-10kva-battery-pack-srt192bp2\" target=\"_blank\" rel=\"noopener\"\u003eSRT192BP2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e±192 V · for SRT 8 kVA \u0026amp; 10 kVA · Tower — the pack for this listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-192v-8-and-10kva-rm-battery-pack-srt192rmbp2\" target=\"_blank\" rel=\"noopener\"\u003eSRT192RMBP2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e±192 V · for SRT 8 kVA \u0026amp; 10 kVA · Rackmount 3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eReplacement battery cartridge\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-apcrbc140\" target=\"_blank\" rel=\"noopener\"\u003eAPCRBC140\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal replacement battery cartridge for the SRT 8 kVA and 10 kVA models — two cartridges per SRT10KXLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eRail kit\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRTRK2\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS SRT 19-inch rail kit for Smart-UPS SRT 5\/6\/8\/10 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eNetwork management and SmartSlot accessories\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-ap9640\" target=\"_blank\" rel=\"noopener\"\u003eAP9640\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eUPS Network Management Card 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\" target=\"_blank\" rel=\"noopener\"\u003eAP9641\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eUPS Network Management Card 3 with Environmental Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-dry-contact-i-o-smartslot-card-ap9613\" target=\"_blank\" rel=\"noopener\"\u003eAP9613\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eDry Contact I\/O SmartSlot Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-temperature-humidity-sensor\" target=\"_blank\" rel=\"noopener\"\u003eAP9335TH\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature \u0026amp; Humidity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/SRT10KXLI\/apc-smartups-online-10kva-10kw-tower-230v-400v-6x-c13+4x-c19-iec-outlets-network-card+smartslot-extended-runtime-w-o-rail-kit\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric Singapore product page — SRT10KXLI\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/download\/document\/SPD_SCON-9DETHW_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eOperation Manual — Smart-UPS On-Line 8\/10 kVA 208\/220\/230\/240 Vac Tower \/ Rack-Mount 6U, wiring specifications and configuration menus (Schneider document 990-4506F, SPD_SCON-9DETHW_EN)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/download\/document\/SPD_VAGL-B3T8YG_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eSmart-UPS On-Line SRT 1 kVA – 10 kVA 230 V Brochure — features, specifications, runtimes and accessories (Schneider document SPD_VAGL-B3T8YG_EN)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/ww\/en\/faqs\/FA349747\" target=\"_blank\" rel=\"noopener\"\u003eSchneider FAQ FA349747 — which external battery pack and RBC fits your Smart-UPS On-Line (SRT) model\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eSchneider's own datasheet download links redirect to a host that has served wrong-model files, so email sales@sourceit.com.sg quoting the SKU SRT10KXLI and we will send you the correct PDF datasheet.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRT10KXLI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 10,000 VA and 10,000 W rating, and how do I size the SRT10KXLI?\u003c\/strong\u003e\u003cbr\u003eVA is apparent power and W is real power. On most UPS families the watt figure is lower than the VA figure, and watts is what limits you — but the SRT10KXLI is a unity power factor design, so it delivers the full 10,000 W. Keep the total real draw below 10,000 W; sizing to about 70–80% leaves headroom for inrush and gives noticeably longer runtime.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long will the SRT10KXLI run on battery?\u003c\/strong\u003e\u003cbr\u003eSchneider's runtime estimator on the Singapore product page shows 3 minutes 45 seconds at the full 10,000 W load on the internal batteries. Runtime is not linear — halving the load more than doubles the time on battery — so a typical 40–50% load runs well beyond that. For defined autonomy, add \u003ca href=\"\/products\/apc-smart-ups-srt-192v-8kva-and-10kva-battery-pack-srt192bp2\" target=\"_blank\" rel=\"noopener\"\u003eSRT192BP2\u003c\/a\u003e packs (up to 10) and ask SourceIT to size the configuration against your measured load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the SRT10KXLI produce a sine wave output, and will it work with an active-PFC power supply?\u003c\/strong\u003e\u003cbr\u003eYes. Schneider specifies a sine wave output with less than 2% harmonic distortion, and the unit is an on-line double-conversion design, so the load is fed from the inverter continuously. That is exactly the output type active-PFC server and workstation power supplies expect.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the SRT10KXLI run from a three-phase supply?\u003c\/strong\u003e\u003cbr\u003eYes. It accepts a 230 V AC single-phase feed (3-wire hardwire, 1P + N + E) or a 380 \/ 400 \/ 415 V AC three-phase feed (5-wire hardwire, 3P + N + E). Output remains single phase either way.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do the XLI and RMXLI suffixes mean?\u003c\/strong\u003e\u003cbr\u003eXLI is the tower build supplied \u003cstrong\u003ewithout\u003c\/strong\u003e a rail kit; RMXLI is the same electronics in a rackmount build supplied \u003cstrong\u003ewith\u003c\/strong\u003e the rail kit. Schneider also produces XLT and XLW variants for other regional voltages, so check the part number against your tender.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich replacement battery does the SRT10KXLI take, and can I change it myself?\u003c\/strong\u003e\u003cbr\u003eThe battery system is a ±192 V split bus and the replacement cartridge is the \u003ca href=\"\/products\/apc-replacement-battery-cartridge-apcrbc140\" target=\"_blank\" rel=\"noopener\"\u003eAPCRBC140\u003c\/a\u003e, two per unit. APC designs the SRT battery modules to be user-replaceable. Expected battery life is three to five years; heat shortens it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I rack-mount the SRT10KXLI?\u003c\/strong\u003e\u003cbr\u003eYes. Schneider lists SRTRK2 or SRTRK3 as the rail kit sold separately; converted, it occupies 6U. If it is going into a cabinet from the start, the \u003ca href=\"\/products\/apc-smart-ups-srt-10000va-rm-230v-srt10krmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT10KRMXLI\u003c\/a\u003e is the 6U rackmount build with rails in the box.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the SRT10KXLI compare with the SRT8KXLI?\u003c\/strong\u003e\u003cbr\u003eSame tower chassis, ±192 V battery architecture, APCRBC140 cartridges and SRT192BP2 packs. The \u003ca href=\"\/products\/apc-smart-ups-srt-8000va-230v-srt8kxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT8KXLI\u003c\/a\u003e is 8,000 VA \/ 8,000 W; the SRT10KXLI is 10,000 VA \/ 10,000 W and needs a heavier supply circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the SRT10KXLI covered by warranty in Singapore?\u003c\/strong\u003e\u003cbr\u003eYes. Every APC SRT10KXLI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRT10KXLI with a 3-year manufacturer warranty on the UPS (repair or replace, excluding the battery) and 2 years on the battery.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482543423652,"sku":"SRT10KXLI","price":9494.4,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_77773fbf-e1da-4bf1-bd3d-3f289444dac0.jpg?v=1789705767","url":"https:\/\/sourceit.com.sg\/products\/apc-smart-ups-srt-10000va-10000w-tower-230v-on-line-double-conversion-srt10kxli","provider":"SourceIT ","version":"1.0","type":"link"}