{"product_id":"apc-smart-ups-rt-5kva-5kw-rack-tower-4u-230v-on-line-srtg5kxli","title":"APC Smart-UPS RT 5kVA 5kW Rack Tower 4U 230V On-Line Double Conversion","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Smart-UPS RT 5kVA 230V International (SRTG5KXLI) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003e5 kVA \/ 5 kW Double-Conversion On-Line UPS for the Singapore Server Room\u003c\/h3\u003e\n\u003cp\u003eThe APC Smart-UPS On-Line SRTG5KXLI is a 5,000 VA \/ 5,000 W double-conversion UPS from the Smart-UPS RT (SRTG) generation, sized for a comms room, a small server room or a clinic's imaging suite. Incoming mains is rectified to DC and regenerated as a clean sine wave, so the load is fed from the inverter continuously rather than switched across when the supply fails. Output voltage distortion is rated at less than 2%, and an internal automatic and manual bypass carries the load if the inverter is overloaded or taken out for service. On a Singapore riser shared with lifts and chillers, that continuous regeneration is what keeps sags and switching transients away from your servers.\u003c\/p\u003e\n\u003ch3\u003eUnity Power Factor, 230 V Single-Phase In and Out\u003c\/h3\u003e\n\u003cp\u003eThe SRTG5KXLI is a unity power factor design: it delivers the full 5,000 W from its 5,000 VA rating, so you size on real watts with nothing lost to a 0.8 or 0.9 multiplier. Input is 230 V single-phase (220 \/ 230 \/ 240 V user-selectable), hard wired through a 3-wire (1P + N + E) terminal block, with a wide 160–285 V window at full load and 100–285 V at half load before the unit has to fall back on its batteries. Output is 230 V at 50\/60 Hz ±4 Hz synchronised to mains (±0.1 Hz on battery), on two IEC C13 outlets, one IEC C19 outlet and a hard-wire 3-wire terminal block. Maximum input current is 28 A and full-load output current is 23 A. Unlike the 15 and 20 kVA units in the range, the 5–10 kVA SRTG models are single-phase only — there is no 400 V three-phase input option.\u003c\/p\u003e\n\u003ch3\u003eBatteries on a ±96 V Bus, Scalable with the SRTG192XLBP4 Pack\u003c\/h3\u003e\n\u003cp\u003eInternal batteries are sealed maintenance-free VRLA, 16 x 12 V 5 Ah cells in two battery modules on a ±96 VDC bus, with the APCRBC170 as the replacement cartridge (quantity 1) and a typical recharge time of 4 hours. Schneider's Smart-UPS RT 5–20 kVA range brochure lists approximately 3 minutes at the full 5,000 W and 10.5 minutes at half load (2,500 W) — a ride-through figure, not autonomy. For generator start-up cover or a multi-server shutdown window, add up to four SRTG192XLBP4 external packs, the 192 V, 5 Ah, 3U pack built for the SRTG 5–10 kVA models. Expected battery life is three to five years; plant-room temperature decides which end you get.\u003c\/p\u003e\n\u003ch3\u003e4U Rack or Tower — and the Rail Kit Is Not Included\u003c\/h3\u003e\n\u003cp\u003eThe SRTG5KXLI is rack \/ tower convertible in a 175 mm (H) x 440 mm (W) x 620 mm (D) chassis, occupying 4U when racked. At 620 mm deep it fits a standard 1,000 mm server cabinet with room for cabling, and the stabiliser brackets for tower use are in the carton. The rail kit is \u003cstrong\u003enot\u003c\/strong\u003e included: order \u003ca href=\"\/products\/apc-smart-ups-rt-19-rail-kit-for-ups-5-6-8-10-15-20kva-srtgrk1\" target=\"_blank\" rel=\"noopener\"\u003eSRTGRK1\u003c\/a\u003e for the UPS (Schneider's product page lists the same kit for the SRTG192XLBP4 pack). Net weight is 55.9 kg (61.8 kg packaged), so plan a two-person lift and mount it low in the cabinet. Acoustic noise is rated at less than 55 dba, quiet enough for a comms room that shares a wall with an office.\u003c\/p\u003e\n\u003ch3\u003eNetwork Management Card 3 Pre-Installed, Colour LCD, Green Mode, Local Singapore Supply\u003c\/h3\u003e\n\u003cp\u003eAn \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\" target=\"_blank\" rel=\"noopener\"\u003eAP9641\u003c\/a\u003e Network Management Card 3 with environmental monitoring is pre-installed, with a one-year Secure NMC subscription per Schneider's listing, so SNMP, HTTPS and PowerChute Network Shutdown work the day it is racked. Local interfaces are serial (RJ45), USB Type B, an EPO terminal with normally-closed contacts, a maintenance-bypass signal (MBS) input and a battery temperature sensor terminal. The multi-colour LCD scrolls input, output, load, battery temperature and charge, runtime and ambient temperature. Green (ECO) mode feeds the load directly from mains at up to 98% efficiency and, per Schneider's manual, returns to inverter or battery within 8 ms of a mains failure; a Generator Mode setting relaxes input sensitivity for sites on standby generators. SourceIT supplies the SRTG5KXLI from Singapore with a GST invoice and local warranty support.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRTG5KXLI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRTG5KXLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS On-Line, 5kVA\/5kW, Rack\/Tower, 230V, 2x IEC C13+1x IEC C19+Hard wire 3-wire (H+N+E) outlets, Network Card, W\/O rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPS Type \/ Topology\u003c\/td\u003e\n\u003ctd\u003eOn-line, double conversion, with internal automatic and manual bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eRack \/ tower convertible, 4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e5,000 VA \/ 5,000 W (unity power factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V (220 V or 240 V user-selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current at Full Load\u003c\/td\u003e\n\u003ctd\u003e23 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±4 Hz synchronised to mains; 50\/60 Hz ±0.1 Hz on battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Distortion\u003c\/td\u003e\n\u003ctd\u003eLess than 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor\u003c\/td\u003e\n\u003ctd\u003e3 : 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 93.5% in double-conversion mode; up to 98% in Green (ECO) mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBypass\u003c\/td\u003e\n\u003ctd\u003eInternal bypass, automatic and manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003e(2) IEC 60320 C13, (1) IEC 60320 C19, (1) hard wire 3-wire (1P + N + E); two controllable outlet groups (16 A and 10 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V single phase (220 \/ 230 \/ 240 V user-selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e160–285 V at full load; 100–285 V at half load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eHard wired — (1) 3-wire (1P + N + E) terminal block; no plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed maintenance-free valve-regulated lead-acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e±96 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Complement\u003c\/td\u003e\n\u003ctd\u003e16 x 12 V 5 Ah in two battery modules (all slots filled, 0 free)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC170 (quantity 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Full Load\u003c\/td\u003e\n\u003ctd\u003eApproximately 3 minutes at 5,000 W (Schneider's Smart-UPS RT 5–20 kVA range brochure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Half Load\u003c\/td\u003e\n\u003ctd\u003eApproximately 10.5 minutes at 2,500 W (Schneider's Smart-UPS RT 5–20 kVA range brochure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Battery Life\u003c\/td\u003e\n\u003ctd\u003e3 to 5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible External Battery Packs\u003c\/td\u003e\n\u003ctd\u003eSRTG192XLBP4 (192 V, 5 Ah, 3U) — up to 4 packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management Card\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\" target=\"_blank\" rel=\"noopener\"\u003eAP9641\u003c\/a\u003e Network Management Card 3 with environmental monitoring, pre-installed, with a 1-year Secure NMC subscription per Schneider's listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Ports\u003c\/td\u003e\n\u003ctd\u003eSerial (RJ45), USB Type B, EPO, maintenance bypass signal (MBS), battery temperature sensor, external battery connector, plus the network port on the management card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmartSlot\u003c\/td\u003e\n\u003ctd\u003e1 slot, occupied by the pre-installed Network Management Card 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes — normally-closed contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Panel\u003c\/td\u003e\n\u003ctd\u003eMulti-colour LCD with five front-panel buttons; scrolling metering of input, output, load, battery, runtime and ambient temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003ePowerChute Network Shutdown via the management card; serial and USB cables supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e4U; rack \/ tower convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e175 mm (H) x 440 mm (W) x 620 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e55.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaged Weight\u003c\/td\u003e\n\u003ctd\u003e61.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRail Kit\u003c\/td\u003e\n\u003ctd\u003eNot included — \u003ca href=\"\/products\/apc-smart-ups-rt-19-rail-kit-for-ups-5-6-8-10-15-20kva-srtgrk1\" target=\"_blank\" rel=\"noopener\"\u003eSRTGRK1\u003c\/a\u003e sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcoustic Level\u003c\/td\u003e\n\u003ctd\u003eLess than 55 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this model — ask us if you need a cooling figure for the room design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-15 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 3,000 m (1% derating per 100 m above 1,000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards \u0026amp; Marks\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, TISI; EN\/IEC 62040-1:2019\/A11:2021; IEC 62040-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e3 years repair or replace excluding the battery; 2 years for the battery (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003e2 years, supplied and supported by SourceIT Pte Ltd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can connect.\u003c\/strong\u003e Output is delivered on (2) IEC C13, (1) IEC C19 and (1) hard wire 3-wire (1P + N + E) terminal block, the IEC outlets forming two controllable groups on 16 A and 10 A circuits. In practice the IEC outlets feed a rack PDU or top-of-rack devices, and the bulk of the load is wired out through the terminal block. Total the real power draw (watts) of everything you intend to protect and keep it below 5,000 W with headroom.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRuntime at stated loads.\u003c\/strong\u003e Schneider's Smart-UPS RT 5–20 kVA range brochure lists approximately 3 minutes at the full 5,000 W and 10.5 minutes at half load (2,500 W). Runtime is not linear — halving the load more than doubles the time on battery. Recharge time is 4 hours. Ask SourceIT for a runtime calculation against your measured load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtended runtime.\u003c\/strong\u003e Connect up to four SRTG192XLBP4 packs in parallel. Each pack is 192 V (±96 V), 5 Ah, 3U, 83.5 kg, and ships with its battery cable and brackets but not the rail kit. The \u003ca href=\"\/products\/apc-smart-ups-rt-192v-9ah-battery-pack-2-rows-srtg192xlbp2\" target=\"_blank\" rel=\"noopener\"\u003eSRTG192XLBP2\u003c\/a\u003e is the ±192 V, 9 Ah pack for the 15 and 20 kVA units and does not fit this UPS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e 4U when racked, in a 175 mm (H) x 440 mm (W) x 620 mm (D) chassis, rack \/ tower convertible. The rail kit is \u003cstrong\u003enot\u003c\/strong\u003e included — order \u003ca href=\"\/products\/apc-smart-ups-rt-19-rail-kit-for-ups-5-6-8-10-15-20kva-srtgrk1\" target=\"_blank\" rel=\"noopener\"\u003eSRTGRK1\u003c\/a\u003e. Each SRTG192XLBP4 pack adds 3U and 83.5 kg, so a UPS with two packs is 10U and roughly 223 kg: check the cabinet's static load rating and mount everything at the bottom. A 600 mm comms cabinet is not deep enough for the 620 mm chassis plus cabling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput and circuit — read this before ordering.\u003c\/strong\u003e The SRTG5KXLI is \u003cstrong\u003ehard wired\u003c\/strong\u003e on the input: a 3-wire (1P + N + E) terminal block, no plug, maximum input current 28 A on a 230 V single-phase supply. A licensed electrician must size and terminate the feeder. For a three-phase input, see the \u003ca href=\"\/products\/apc-smart-ups-rt-15kva-230v-international-srtg15kxli\" target=\"_blank\" rel=\"noopener\"\u003eSRTG15KXLI\u003c\/a\u003e or \u003ca href=\"\/products\/apc-smart-ups-rt-20kva-230v-international-srtg20kxli\" target=\"_blank\" rel=\"noopener\"\u003eSRTG20KXLI\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Smart-UPS RT (SRTG) Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eIn the box (per Schneider's installation manual):\u003c\/strong\u003e front bezel, RJ45-to-DB9 serial cable, USB cable, one IEC C13\/C14 10 A 1.5 m lead and one IEC C19\/C20 lead, hard-wire terminals, M5 floating nuts and screws, M4 x 6 flat-head screws, rack-mount brackets, two pairs of stabiliser brackets with connectors, installation manual and packing list. The \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\" target=\"_blank\" rel=\"noopener\"\u003eAP9641\u003c\/a\u003e Network Management Card 3 is pre-installed; the rail kit is \u003cstrong\u003enot\u003c\/strong\u003e included. The two IEC leads are output jumper leads, not input cords — the input is hard wired, so there is no Schuko plug to worry about.\u003c\/p\u003e\n\u003ch4\u003eSmart-UPS RT (SRTG) range at SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSRTG5KXLI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5,000 VA \/ 5,000 W · Rack \/ Tower 4U · 230 V 1-phase · no rail kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRTG6KXLI\u003c\/td\u003e\n\u003ctd\u003e6,000 VA \/ 6,000 W · Rack \/ Tower 4U · 230 V 1-phase · no rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRTG8KXLI\u003c\/td\u003e\n\u003ctd\u003e8,000 VA \/ 8,000 W · Rack \/ Tower 5U · 230 V 1-phase · no rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRTG10KXLI\u003c\/td\u003e\n\u003ctd\u003e10,000 VA \/ 10,000 W · Rack \/ Tower 5U · 230 V 1-phase · no rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-rt-15kva-230v-international-srtg15kxli\" target=\"_blank\" rel=\"noopener\"\u003eSRTG15KXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e15,000 VA \/ 15,000 W · 7U · 230 V or 400 V 3-phase input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-rt-20kva-230v-international-srtg20kxli\" target=\"_blank\" rel=\"noopener\"\u003eSRTG20KXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20,000 VA \/ 20,000 W · 7U · 230 V or 400 V 3-phase input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMatching external battery packs and rail kits\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRTG192XLBP4\u003c\/td\u003e\n\u003ctd\u003e192 V (±96 V), 5 Ah pack for SRTG5KXLI \/ SRTG6KXLI \/ SRTG8KXLI \/ SRTG10KXLI · 3U · up to 4 packs · rail kit not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-rt-19-rail-kit-for-ups-5-6-8-10-15-20kva-srtgrk1\" target=\"_blank\" rel=\"noopener\"\u003eSRTGRK1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e19-inch rail kit for the SRTG UPS 5–20 kVA, also listed by Schneider for the SRTG192XLBP4 pack — sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRTGRK2\u003c\/td\u003e\n\u003ctd\u003e19-inch rail kit for the SRTG192XLBP2 pack (15 \/ 20 kVA systems) — sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eReplacement battery cartridges\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPCRBC170\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for the SRTG 5 kVA and 6 kVA units (quantity 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPCRBC174\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for the SRTG 8 kVA and 10 kVA units (quantity 2) and for the SRTG192XLBP4 pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eCartridges are sourced to order — email sales@sourceit.com.sg with the part number printed on your unit.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/SRTG5KXLI\/apc-smartups-online-5kva-5kw-rack-tower-230v-2x-iec-c13+1x-iec-c19+hard-wire-3wire-h+n+e-outlets-network-card-w-o-rail-kit\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric Singapore product page — SRTG5KXLI\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/download\/document\/SPD_AHUG_990-6199_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual — APC Smart-UPS RT SRTG5KXLI \/ SRTG6KXLI (Schneider document SPD_AHUG_990-6199_EN)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/download\/document\/SPD_AHUG_990-6200_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual, with package contents — APC Smart-UPS RT SRTG5K \/ SRTG6K (Schneider document SPD_AHUG_990-6200_EN)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/download\/document\/SPD_ABAR-SURTOL_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eRange brochure with comparison table — APC Smart-UPS RT On-Line 5–20 kVA (Schneider document SPD_ABAR-SURTOL_EN)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eSchneider's own datasheet download links redirect to a document host that has served wrong-model files, so we do not publish those links here. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eSRTG5KXLI\u003c\/strong\u003e and we will send you the current PDF datasheet directly.\u003c\/p\u003e\n\u003cp\u003eLinks open on Schneider Electric’s official product and document servers.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRTG5KXLI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 5,000 VA and 5,000 W rating, and how do I size the SRTG5KXLI?\u003c\/strong\u003e\u003cbr\u003eVA is apparent power and W is real power. On many UPS families the watt figure is lower and watts is what limits you — but the SRTG5KXLI is a unity power factor design, so it delivers the full 5,000 W. Add up the real draw of everything you want on battery and keep the total below 5,000 W with headroom.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long will the SRTG5KXLI run on battery?\u003c\/strong\u003e\u003cbr\u003eSchneider's Smart-UPS RT 5–20 kVA range brochure lists approximately 3 minutes at the full 5,000 W and 10.5 minutes at half load (2,500 W). That is deliberately short — a UPS at this capacity is sized to ride through a dip and cover a generator start or an orderly shutdown. For longer autonomy add SRTG192XLBP4 packs, up to four. Recharge time is 4 hours.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the SRTG5KXLI take a three-phase supply?\u003c\/strong\u003e\u003cbr\u003eNo. The 5, 6, 8 and 10 kVA SRTG models are single-phase only: 230 V in (220 \/ 230 \/ 240 V selectable), 230 V out, hard wired through a 3-wire (1P + N + E) terminal block. For a 400 V three-phase input or 3:1 operation, look at the \u003ca href=\"\/products\/apc-smart-ups-rt-15kva-230v-international-srtg15kxli\" target=\"_blank\" rel=\"noopener\"\u003eSRTG15KXLI\u003c\/a\u003e and \u003ca href=\"\/products\/apc-smart-ups-rt-20kva-230v-international-srtg20kxli\" target=\"_blank\" rel=\"noopener\"\u003eSRTG20KXLI\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the SRTG5KXLI produce a sine wave output, and will it work with an active-PFC power supply?\u003c\/strong\u003e\u003cbr\u003eYes. It is an on-line double-conversion design with a sine wave output rated at less than 2% voltage distortion, so the load is fed from the inverter continuously. That is the output type active-PFC server and storage power supplies expect.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich replacement battery does the SRTG5KXLI take?\u003c\/strong\u003e\u003cbr\u003eThe APCRBC170, quantity 1. The internal batteries are sealed maintenance-free VRLA, 16 x 12 V 5 Ah cells in two battery modules on a ±96 VDC bus. This is a different cartridge from the APCRBC140 used across the older SRT 5–10 kVA range and the APCRBC172 in the SRTG 15 and 20 kVA units — do not order by analogy. Expected service life is three to five years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich external battery pack fits, and how many can I add?\u003c\/strong\u003e\u003cbr\u003eThe SRTG192XLBP4 — 192 V (±96 V), 5 Ah, 3U, 83.5 kg — and you can connect up to four in parallel. The \u003ca href=\"\/products\/apc-smart-ups-rt-192v-9ah-battery-pack-2-rows-srtg192xlbp2\" target=\"_blank\" rel=\"noopener\"\u003eSRTG192XLBP2\u003c\/a\u003e is a different product for the 15 and 20 kVA units (±192 V, 9 Ah, 4U, 116 kg) and does not connect to this UPS. Each XLBP4 pack ships with its battery cable and mounting brackets but not the rail kit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the SRTG5KXLI compare with the SRTG6KXLI?\u003c\/strong\u003e\u003cbr\u003eSame 4U chassis, 55.9 kg, sixteen-cell battery set, APCRBC170 cartridge and pre-installed management card. The SRTG6KXLI carries 6 kW instead of 5 kW on the same battery, so its published full-load runtime is shorter (approximately 2 minutes against 3) and its maximum input current is 33 A against 28 A. Under 5,000 W measured load this unit gives more minutes on battery; above it, or with growth expected, take the SRTG6KXLI. For 8 kW and above, the 5U SRTG8KXLI and SRTG10KXLI double the battery complement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the SRTG5KXLI covered by warranty in Singapore?\u003c\/strong\u003e\u003cbr\u003eYes. Every APC SRTG5KXLI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRTG5KXLI with a 3-year manufacturer warranty on the UPS (excluding the battery) and 2 years on the battery.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482544177316,"sku":"SRTG5KXLI","price":4581.6,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_889a87bb-e523-4e2a-a500-d701e63b5a18.jpg?v=1789705780","url":"https:\/\/sourceit.com.sg\/products\/apc-smart-ups-rt-5kva-5kw-rack-tower-4u-230v-on-line-srtg5kxli","provider":"SourceIT ","version":"1.0","type":"link"}