{"product_id":"apc-netshelter-sx-42u-750mm-wide-1200mm-deep-networking-rack-enclosure-black-ar3340","title":"APC NetShelter SX 42U 750mm Wide 1200mm Deep Networking Rack Enclosure","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter SX, Networking Rack Enclosure, 42U, Black, 1991H x 750W x 1200D mm (AR3340) - 5 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eAPC AR3340 — the NetShelter SX networking enclosure: 42U, 750 mm wide, 1200 mm deep\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC AR3340 is the NetShelter SX cabinet from APC by Schneider Electric that is built for the network core rather than the server row: 1991 mm high, 750 mm wide and 1200 mm deep, with 16-gauge perforated front and rear doors, locking side panels, a roof designed for cable access, pre-installed castors, levelling feet and integrated high-density cable managers. Schneider's own description is a rack \"designed specifically for large core networking switches\" that \"helps enable faster deployment of network switches\".\u003c\/p\u003e\n\u003cp\u003eThe extra 150 mm of width over a 600 mm cabinet and the 1200 mm depth are there for one reason: a chassis switch or a stack of 48-port switches with hundreds of patch leads needs somewhere to route them. A 600 mm server rack fills up with cable long before it fills up with equipment; the AR3340 does not.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e1200 mm deep, 1701 kg static, 16-gauge doors\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe rails adjust from 279 mm to 959 mm apart, so a deep chassis switch and its rear-mounted power supplies fit with room for 0U PDUs and cable managers behind. The frame is rated for 1701 kg static and 1021 kg dynamic — higher than the standard SX server rack — with 16-gauge front and rear doors, 18-gauge side panels and roof. A fully patched core cabinet with a UPS at the bottom is a heavy load, and the rating reflects that.\u003c\/p\u003e\n\u003cp\u003eDoors and side panels lock and are keyed alike; baying hardware and mounting hardware are in the box. Net weight is 161.4 kg and the palletised shipment is 183.2 kg at 2118 mm high, 851 mm wide and 1321 mm long — plan the goods lift and unpack at the loading bay if a doorway is in the way.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCable management and airflow for a switch-dense rack\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AR3340 carries integrated high-density cable managers and vertical cable managers as standard, plus an improved cable-access roof for overhead trunking, so patch leads run vertically beside the rails and enter from above without a separate cable-management purchase. The doors are perforated for front-to-back airflow, and Schneider notes the enclosure is ready for airflow isolation — containment or ducting — where the room is set up for it. Blank the unused U with AR8136BLK toolless panels to keep cold air going through the switches.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSingapore installation notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSchneider requires the cabinet to be earthed and bolted to the floor before it is loaded; the AR7701 bolt-down kit is the matching part. Allow for the 750 mm width when laying out a row on 600 mm floor tiles — an AR3340 is often paired with 600 mm AR3100 server cabinets either side of it. Everything SourceIT ships is local Singapore stock with a GST invoice and Schneider's printed 5-year repair-or-replace warranty behind it.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AR3340 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eFigures below are taken from the Schneider Electric product page and the APC AR3340 product data sheet as carried on Schneider's iPortal and by an independent distributor mirror that agree. Where Schneider does not publish a value for this exact part number, the row is left out rather than filled in from a similar model.\u003c\/p\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAR3340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter SX, Networking Rack Enclosure, 42U, Black, 1991H x 750W x 1200D mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter SX (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFloor-standing 19-inch networking rack enclosure with sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eLarge core switches and high-density networking; medium to high density environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003e5 years repair or replace, as printed on the Schneider data sheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupported locally by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDimensions \u0026amp; Capacity\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e42U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e1991 mm x 750 mm x 1200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Width\u003c\/td\u003e\n\u003ctd\u003e19 inch (EIA-310-E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Rail Depth Range\u003c\/td\u003e\n\u003ctd\u003e279 mm to 959 mm (front rail to rear rail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Static Load\u003c\/td\u003e\n\u003ctd\u003e1701 kg (3750 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Dynamic (Rolling) Load\u003c\/td\u003e\n\u003ctd\u003e1021 kg (2250 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e161.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eConstruction \u0026amp; Access\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Door\u003c\/td\u003e\n\u003ctd\u003ePerforated, 16 gauge, locking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Door\u003c\/td\u003e\n\u003ctd\u003ePerforated, 16 gauge, locking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide Panels\u003c\/td\u003e\n\u003ctd\u003eIncluded, 18 gauge, locking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoof\u003c\/td\u003e\n\u003ctd\u003eIncluded, 18 gauge, improved cable-access design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocks\u003c\/td\u003e\n\u003ctd\u003eDoors and side panels keyed alike; keys supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCastors\u003c\/td\u003e\n\u003ctd\u003ePre-installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLevelling Feet\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaying\u003c\/td\u003e\n\u003ctd\u003eBaying hardware supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eAirflow \u0026amp; Cable Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Management\u003c\/td\u003e\n\u003ctd\u003eIntegrated high-density cable managers and vertical cable managers included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Entry\u003c\/td\u003e\n\u003ctd\u003eCable-access roof for overhead entry; open base for raised-floor entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003eFront-to-back through perforated doors; ready for airflow isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlanking Panels\u003c\/td\u003e\n\u003ctd\u003eUse AR8136BLK 1U toolless panels (pack of 10) in unused U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e42U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions (H x W x L)\u003c\/td\u003e\n\u003ctd\u003e2118 mm x 851 mm x 1321 mm, on pallet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e183.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEIA-310-E, UL 2416, UL 60950-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat fits in the frame\u003c\/h4\u003e\n\u003cp\u003eAny EIA-310 19-inch equipment, and specifically the large chassis switches and dense 1U switch stacks that a 600 mm rack struggles with. The 279 mm to 959 mm rail range takes deep core-switch chassis, and the 150 mm of extra width either side of the rails is where the integrated vertical cable managers and the patch-lead bundles live.\u003c\/p\u003e\n\u003ch4\u003eRack accessories that belong to this cabinet\u003c\/h4\u003e\n\u003cp\u003eThe AR7701 bolt-down kit anchors the SX frame. The AR8122BLK 1U fixed shelf carries 114 kg of non-rack equipment. The AR8136BLK blanking panels close off unused U so cooling air goes through the switches. All three are on this site.\u003c\/p\u003e\n\u003ch4\u003ePower for a network core\u003c\/h4\u003e\n\u003cp\u003eCore switches are usually dual-corded; feed the two supplies from two 0U PDUs in the rear channels on separate circuits, or from a UPS-backed PDU and a raw-mains PDU. Single-corded access switches go behind a rack ATS such as the \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423 Rack ATS 16 A\u003c\/a\u003e or \u003ca href=\"\/products\/apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424\"\u003eAP4424 Rack ATS 32 A\u003c\/a\u003e. For the UPS, the \u003ca href=\"\/products\/apc-smart-ups-on-line-3kva-rackmount-2u-230v-8x-c13-2x-c19-iec-srt3000rmxli\"\u003eSmart-UPS SRT3000RMXLI\u003c\/a\u003e on-line double conversion in 2U is the usual pairing for a switch-dense rack, with the \u003ca href=\"\/products\/apc-smart-ups-rt-5kva-5kw-rack-tower-4u-230v-on-line-srtg5kxli\"\u003eSmart-UPS RT SRTG5KXLI\u003c\/a\u003e where the load approaches 5 kVA.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552 Rack PDU Basic 0U 16 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU Basic 0U, 16 A, 230 V — mounts in the rear 0U channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-32a-230v-ap7553\"\u003eAP7553 Rack PDU Basic 0U 32 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU Basic 0U, 32 A, 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B NetShelter Switched Rack PDU\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched Rack PDU, 1U, 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853 NetShelter Metered Rack PDU\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered Rack PDU, 0U, 32 A — has a sensor port of its own\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858 NetShelter Metered Rack PDU\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered Rack PDU, 0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-10a-c14-in-12-c13-out\"\u003eAP4421 Rack ATS 10 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack ATS, 10 A, C14 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423 Rack ATS 16 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack ATS, 16 A, C20 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424\"\u003eAP4424 Rack ATS 32 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack ATS, 32 A, IEC 309 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNetBotz Rack Monitor 250 (NBRK0250A)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNetBotz Rack Monitor 250, 1U — door, temperature, leak and access monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMonitoring\u003c\/h4\u003e\n\u003cp\u003eA core rack is the one you most want to know about. The \u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNetBotz Rack Monitor 250 (NBRK0250A)\u003c\/a\u003e gives door-open, temperature, humidity and leak alerts with badged access control for two doors; an \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641 Network Management Card\u003c\/a\u003e in the UPS SmartSlot with an \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH temperature and humidity sensor\u003c\/a\u003e is the lighter option.\u003c\/p\u003e\n\u003ch4\u003eChoosing between the SX sizes\u003c\/h4\u003e\n\u003cp\u003eAR3340 for the network core and heavy patching; AR3100 (600 x 1070 mm) for server rows; AR3104 for a half-height branch cabinet. The Easy Rack ER8202 (800 x 1000 mm) is the value alternative for a wide patching rack where SX features are not required.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; APC NetShelter SX Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cp\u003eOne assembled NetShelter SX 42U networking enclosure with perforated front and rear doors, two side panels, cable-access roof, integrated high-density and vertical cable managers, pre-installed castors, levelling feet, keys (doors and side panels keyed alike), mounting hardware and baying hardware — the list Schneider prints on the data sheet. Shipped on a pallet.\u003c\/p\u003e\n\u003ch4\u003eAPC NetShelter SX enclosures and accessories at SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eAR3100\u003c\/td\u003e\n\u003ctd\u003eNetShelter SX 42U, 600 mm W x 1070 mm D — standard server enclosure, 1364 kg static\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAR3104\u003c\/td\u003e\n\u003ctd\u003eNetShelter SX 24U, 600 mm W x 1070 mm D — half-height server enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAR3340 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNetShelter SX 42U, 750 mm W x 1200 mm D — networking enclosure, 1701 kg static\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAR7701\u003c\/td\u003e\n\u003ctd\u003eNetShelter SX bolt-down kit — floor anchoring brackets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAR8122BLK\u003c\/td\u003e\n\u003ctd\u003eFixed shelf, 1U, 114 kg rated, black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAR8136BLK\u003c\/td\u003e\n\u003ctd\u003e1U toolless blanking panels, pack of 10, black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eER6202 \/ ER6212 \/ ER8202\u003c\/td\u003e\n\u003ctd\u003eEasy Rack 42U value cabinets in 600 x 1000, 600 x 1100 and 800 x 1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-6u-low-profile-wallmount-rack-enclosure-ar106vi\"\u003eAR106VI NetShelter 6U wall-mount enclosure\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNetShelter 6U wall-mount enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eRack power and monitoring to go with it\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552 Rack PDU Basic 0U 16 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU Basic 0U, 16 A, 230 V — mounts in the rear 0U channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-32a-230v-ap7553\"\u003eAP7553 Rack PDU Basic 0U 32 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU Basic 0U, 32 A, 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B NetShelter Switched Rack PDU\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched Rack PDU, 1U, 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853 NetShelter Metered Rack PDU\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered Rack PDU, 0U, 32 A — has a sensor port of its own\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858 NetShelter Metered Rack PDU\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered Rack PDU, 0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-10a-c14-in-12-c13-out\"\u003eAP4421 Rack ATS 10 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack ATS, 10 A, C14 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423 Rack ATS 16 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack ATS, 16 A, C20 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424\"\u003eAP4424 Rack ATS 32 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack ATS, 32 A, IEC 309 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNetBotz Rack Monitor 250 (NBRK0250A)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNetBotz Rack Monitor 250, 1U — door, temperature, leak and access monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eLinks open on Schneider Electric's own site. Each one was checked before publication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/product\/AR3340\/netshelter-sx-42u-750mm-wide-x-1200mm-deep-networking-enclosure-with-sides-black\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for the APC AR3340 (United States site) — official product name, characteristics and the full document list including the NetShelter SX networking enclosure user guide 990-3548D\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/za\/en\/product\/AR3340\/netshelter-sx-42u-750mm-wide-x-1200mm-deep-networking-enclosure-with-sides\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for the APC AR3340 (South Africa site) — features and documents\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's own datasheet download links redirect to a host that has served wrong-model files, so for the PDF datasheet or manual as a file for a tender, email sales@sourceit.com.sg quoting the SKU and we will send the correct document.\u003c\/p\u003e\n\u003cp\u003eNeed a compliance declaration, a CAD file or a written quotation for a tender? Contact SourceIT and we will supply it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AR3340\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhy 750 mm wide instead of 600 mm?\u003c\/h4\u003e\n\u003cp\u003eCable. A 42U rack of 48-port switches carries well over a thousand patch leads, and in a 600 mm cabinet they end up in front of the equipment. The 750 mm AR3340 puts vertical cable managers beside the rails so leads route cleanly and the doors still close.\u003c\/p\u003e\n\u003ch4\u003eWill it fit on a 600 mm floor tile grid?\u003c\/h4\u003e\n\u003cp\u003eIt is 750 mm wide, so it does not align with a 600 mm tile pitch on its own. Rows are usually laid out with the AR3340 as the core cabinet and 600 mm AR3100 server cabinets either side; tell us the room dimensions and we will help with the layout.\u003c\/p\u003e\n\u003ch4\u003eWhat is the load rating?\u003c\/h4\u003e\n\u003cp\u003e1701 kg static and 1021 kg dynamic — higher than the standard SX server rack, because a fully patched core cabinet with a rack UPS at the bottom is a heavy load.\u003c\/p\u003e\n\u003ch4\u003eDoes it include cable management?\u003c\/h4\u003e\n\u003cp\u003eYes. Integrated high-density cable managers and vertical cable managers are part of the enclosure, and the roof is designed for overhead cable access, so the usual separate cable-manager purchase is not needed.\u003c\/p\u003e\n\u003ch4\u003eIs the rear door split?\u003c\/h4\u003e\n\u003cp\u003eSchneider describes the AR3340 with a 16-gauge front door and a 16-gauge rear door; the split-rear-door arrangement is a feature of the 600 mm server enclosures. Allow full rear door swing clearance behind an AR3340.\u003c\/p\u003e\n\u003ch4\u003eWhich UPS and PDUs go with it?\u003c\/h4\u003e\n\u003cp\u003eDual-corded core switches take two 0U PDUs in the rear channels on separate feeds, for example two \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-32a-230v-ap7553\"\u003eAP7553 Rack PDU Basic 0U 32 A\u003c\/a\u003e units, with a \u003ca href=\"\/products\/apc-smart-ups-on-line-3kva-rackmount-2u-230v-8x-c13-2x-c19-iec-srt3000rmxli\"\u003eSmart-UPS SRT3000RMXLI\u003c\/a\u003e or \u003ca href=\"\/products\/apc-smart-ups-rt-5kva-5kw-rack-tower-4u-230v-on-line-srtg5kxli\"\u003eSmart-UPS RT SRTG5KXLI\u003c\/a\u003e UPS at the bottom. Single-corded switches go behind a \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423 Rack ATS 16 A\u003c\/a\u003e rack ATS.\u003c\/p\u003e\n\u003ch4\u003eHow is it delivered?\u003c\/h4\u003e\n\u003cp\u003eAssembled on a pallet: 183.2 kg, 2118 mm high, 851 mm wide and 1321 mm long. It needs a goods lift, and if a doorway is lower than 2.12 m, unpack at the loading bay and roll the 1991 mm cabinet in on its castors.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC AR3340 sold by SourceIT comes with local Singapore warranty support and a GST invoice; APC by Schneider Electric prints a 5-year repair-or-replace warranty for the NetShelter SX enclosure, which is the term we pass on.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482613448868,"sku":"AR3340","price":4949.6,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_1d7664bf-3eff-4157-a803-443765a9dfe1.png?v=1789716606","url":"https:\/\/sourceit.com.sg\/products\/apc-netshelter-sx-42u-750mm-wide-1200mm-deep-networking-rack-enclosure-black-ar3340","provider":"SourceIT ","version":"1.0","type":"link"}