{"product_id":"apc-netshelter-sx-42u-600mm-wide-1070mm-deep-server-rack-enclosure-black-ar3100","title":"APC NetShelter SX 42U 600mm Wide 1070mm Deep Server Rack Enclosure","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter SX, Server Rack Enclosure, 42U, Black, 1991H x 600W x 1070D mm (AR3100) - 5 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eAPC AR3100 — the standard 42U NetShelter SX server enclosure, 600 mm wide and 1070 mm deep\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC AR3100 is the NetShelter SX 42U enclosure that most Singapore server rooms are built around: 1991 mm high, 600 mm wide and 1070 mm deep, delivered assembled with a perforated front door, split perforated rear doors, locking side panels, a roof, pre-installed castors and levelling feet. NetShelter SX is the premium rack line from APC by Schneider Electric — the one its Smart-UPS, rack PDU, NetBotz and InRow cooling accessories are designed and tested against — and the AR3100 is the base model in that line.\u003c\/p\u003e\n\u003cp\u003eSchneider positions it for low to medium density server and networking applications. The 600 mm width is compact enough to optimise floor space and line up on a 600 mm tile, and the 42U height is chosen so the cabinet rolls through a standard doorway without being tilted.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSplit rear doors, 1070 mm depth and a 1364 kg frame\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe rear doors are split — two half-width perforated doors rather than one — so the cabinet only needs a narrow aisle behind it to get at the PDUs and power leads. Front and rear doors lock, the front with a three-point latch, and open wide enough for a technician to slide a server in on rails. The side panels lock with the same key. All of it lifts off without tools when you need to bay cabinets or work on cabling from the side.\u003c\/p\u003e\n\u003cp\u003eThe 1070 mm depth gives a mounting-rail adjustment range from 191 mm to 915 mm between front and rear rails, which handles a full-depth 2U server with its rail kit and still leaves room behind for two 0U rack PDUs in the rear channels. The frame is rated 1364 kg static and 1023 kg dynamic — the dynamic figure is the one that matters if you intend to pre-build the rack and roll it into position loaded. Posts are 16 gauge steel, the front door 16 gauge, the rear doors, roof and side panels 18 gauge, and the EIA mounting rails 14 gauge.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBuilt for airflow and cable management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNetShelter SX doors are perforated for front-to-back airflow, which is the cooling model that every modern server, switch and rack UPS assumes. Blank the unused U with AR8136BLK toolless panels and the cold air from the aisle goes through the equipment rather than around it. Four repositionable 0U accessory channels in the rear corners take rack PDUs and vertical cable managers without consuming rack units, and the roof has cable openings for overhead trunking, with the base open for raised-floor entry.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSingapore installation notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNet weight is 125.1 kg and it ships on a pallet at 144.6 kg, 2118 mm high, so plan a goods lift and, if the crate has to go through a door, unpack at the loading bay and roll the cabinet in. Schneider requires the cabinet to be earthed to the building bonding network and secured to the floor before it is loaded; the matching AR7701 bolt-down kit is stocked alongside it. Everything SourceIT ships is local Singapore stock with a GST invoice and Schneider's printed 5-year repair-or-replace warranty behind it.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AR3100 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eFigures below are taken from the Schneider Electric product page (Singapore) and the APC AR3100 product data sheet as carried by two independent distributor mirrors that agree. Where Schneider does not publish a value for this exact part number, or where the two data sheet copies disagree, the row is left out rather than guessed.\u003c\/p\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAR3100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter SX, Server Rack Enclosure, 42U, Black, 1991H x 600W x 1070D mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter SX (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFloor-standing 19-inch server rack enclosure with sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eLow to medium density server and networking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003e5 years repair or replace, as printed on the Schneider data sheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupported locally by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDimensions \u0026amp; Capacity\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e42U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e1991 mm x 600 mm x 1070 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Width\u003c\/td\u003e\n\u003ctd\u003e19 inch (EIA-310-E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Rail Depth Range\u003c\/td\u003e\n\u003ctd\u003e191 mm to 915 mm (front rail to rear rail)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Static Load\u003c\/td\u003e\n\u003ctd\u003e1364 kg (3000 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Dynamic (Rolling) Load\u003c\/td\u003e\n\u003ctd\u003e1023 kg (2250 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e125.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eConstruction \u0026amp; Access\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Door\u003c\/td\u003e\n\u003ctd\u003ePerforated, 16 gauge, locking, removable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Doors\u003c\/td\u003e\n\u003ctd\u003eSplit (two half-width) perforated doors, 18 gauge, locking, removable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide Panels\u003c\/td\u003e\n\u003ctd\u003eIncluded, 18 gauge, locking, removable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoof\u003c\/td\u003e\n\u003ctd\u003eIncluded, 18 gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVertical Posts\u003c\/td\u003e\n\u003ctd\u003e16 gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEIA Mounting Rails\u003c\/td\u003e\n\u003ctd\u003e14 gauge, square hole, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocks\u003c\/td\u003e\n\u003ctd\u003eDoors and side panels keyed alike; keys supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCastors\u003c\/td\u003e\n\u003ctd\u003ePre-installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLevelling Feet\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaying\u003c\/td\u003e\n\u003ctd\u003eBaying hardware supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eAirflow \u0026amp; Cable Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003eFront-to-back through perforated front and rear doors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0U Accessory Channels\u003c\/td\u003e\n\u003ctd\u003eRear accessory channels for 0U rack PDUs and vertical cable managers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Entry\u003c\/td\u003e\n\u003ctd\u003eRoof cable openings for overhead entry; open base for raised-floor entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlanking Panels\u003c\/td\u003e\n\u003ctd\u003eUse AR8136BLK 1U toolless panels (pack of 10) in unused U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarthing\u003c\/td\u003e\n\u003ctd\u003eBond to the building common bonding network before loading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e42U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Height\u003c\/td\u003e\n\u003ctd\u003e2118 mm, on pallet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e144.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEIA-310-E, UL 2416, UL 60950-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eRoHS, China RoHS, REACH (contains no SVHCs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat fits in the frame\u003c\/h4\u003e\n\u003cp\u003eAny EIA-310 19-inch equipment. The AR3100 is the enclosure Schneider designs its own rack-mount products around, so every rail kit on a Smart-UPS, Smart-UPS SRT or Easy UPS SRV rack model, every NetShelter rack PDU and every NetBotz appliance fits without adapters. The 191 mm to 915 mm rail range takes anything from a patch panel to a full-depth server, and the square-hole rails accept cage nuts and toolless server rails alike.\u003c\/p\u003e\n\u003ch4\u003eRack accessories that belong to this cabinet\u003c\/h4\u003e\n\u003cp\u003eThe AR7701 bolt-down kit anchors the SX frame to the slab and is the part Schneider intends for this purpose. The AR8122BLK fixed shelf carries 114 kg of non-rack gear — a tower UPS, a desktop switch, a KVM — on 1U. The AR8136BLK blanking panels snap into the square-hole rails without tools to close off empty U. All three are on this site.\u003c\/p\u003e\n\u003ch4\u003eUPS, PDU and ATS pairing\u003c\/h4\u003e\n\u003cp\u003eA 42U SX cabinet is normally powered by a rack UPS at the bottom feeding one or two 0U PDUs in the rear channels. The \u003ca href=\"\/products\/apc-smart-ups-1500va-lcd-rm-2u-230v-with-smartconnect-smt1500rmi2uc\"\u003eSmart-UPS SMT1500RMI2UC\u003c\/a\u003e in 2U line-interactive or the \u003ca href=\"\/products\/apc-smart-ups-on-line-3kva-rackmount-2u-230v-8x-c13-2x-c19-iec-srt3000rmxli\"\u003eSmart-UPS SRT3000RMXLI\u003c\/a\u003e in 2U on-line are the common 230 V pairings; the \u003ca href=\"\/products\/apc-smart-ups-rt-5kva-5kw-rack-tower-4u-230v-on-line-srtg5kxli\"\u003eSmart-UPS RT SRTG5KXLI\u003c\/a\u003e covers a rack that approaches 5 kVA. Feed the PDUs from the UPS, and where two supplies are available put a rack ATS such as the \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423 Rack ATS 16 A\u003c\/a\u003e in front of single-corded switches.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552 Rack PDU Basic 0U 16 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU Basic 0U, 16 A, 230 V — mounts in the rear 0U channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-32a-230v-ap7553\"\u003eAP7553 Rack PDU Basic 0U 32 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU Basic 0U, 32 A, 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B NetShelter Switched Rack PDU\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched Rack PDU, 1U, 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853 NetShelter Metered Rack PDU\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered Rack PDU, 0U, 32 A — has a sensor port of its own\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858 NetShelter Metered Rack PDU\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered Rack PDU, 0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-10a-c14-in-12-c13-out\"\u003eAP4421 Rack ATS 10 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack ATS, 10 A, C14 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423 Rack ATS 16 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack ATS, 16 A, C20 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424\"\u003eAP4424 Rack ATS 32 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack ATS, 32 A, IEC 309 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNetBotz Rack Monitor 250 (NBRK0250A)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNetBotz Rack Monitor 250, 1U — door, temperature, leak and access monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMonitoring and cooling\u003c\/h4\u003e\n\u003cp\u003eFit the \u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNetBotz Rack Monitor 250 (NBRK0250A)\u003c\/a\u003e at the top of the rack for temperature, humidity, door-open and leak alerts across the cabinet, or if the UPS has a SmartSlot, an \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641 Network Management Card\u003c\/a\u003e with an \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH temperature and humidity sensor\u003c\/a\u003e is the lower-cost route. Keep the doors closed and the unused U blanked so the room's air-conditioning does its job through the equipment rather than around it.\u003c\/p\u003e\n\u003ch4\u003eChoosing between the SX sizes\u003c\/h4\u003e\n\u003cp\u003eAR3100 is the 42U server rack. AR3104 is the same footprint at 24U for a branch, a lab or a room with low ceilings. AR3340 is 750 mm wide and 1200 mm deep, built for core switches and heavy patching. If the budget does not stretch to SX, the Easy Rack ER6202 shares the 600 x 1000 mm footprint with a single-piece rear door.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; APC NetShelter SX Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cp\u003eOne assembled NetShelter SX 42U enclosure with front door, split rear doors, two side panels, roof, pre-installed castors, levelling feet, keys (doors and side panels keyed alike), mounting hardware and baying hardware — the list Schneider prints on the data sheet. Shipped on a pallet.\u003c\/p\u003e\n\u003ch4\u003eAPC NetShelter SX enclosures and accessories at SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAR3100 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNetShelter SX 42U, 600 mm W x 1070 mm D — standard server enclosure, 1364 kg static\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAR3104\u003c\/td\u003e\n\u003ctd\u003eNetShelter SX 24U, 600 mm W x 1070 mm D — half-height server enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAR3340\u003c\/td\u003e\n\u003ctd\u003eNetShelter SX 42U, 750 mm W x 1200 mm D — networking enclosure, 1701 kg static\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAR7701\u003c\/td\u003e\n\u003ctd\u003eNetShelter SX bolt-down kit — floor anchoring brackets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAR8122BLK\u003c\/td\u003e\n\u003ctd\u003eFixed shelf, 1U, 114 kg rated, black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAR8136BLK\u003c\/td\u003e\n\u003ctd\u003e1U toolless blanking panels, pack of 10, black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eER6202 \/ ER6212 \/ ER8202\u003c\/td\u003e\n\u003ctd\u003eEasy Rack 42U value cabinets in 600 x 1000, 600 x 1100 and 800 x 1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-6u-low-profile-wallmount-rack-enclosure-ar106vi\"\u003eAR106VI NetShelter 6U wall-mount enclosure\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNetShelter 6U wall-mount enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eRack power and monitoring to go with it\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552 Rack PDU Basic 0U 16 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU Basic 0U, 16 A, 230 V — mounts in the rear 0U channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-32a-230v-ap7553\"\u003eAP7553 Rack PDU Basic 0U 32 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU Basic 0U, 32 A, 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B NetShelter Switched Rack PDU\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched Rack PDU, 1U, 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853 NetShelter Metered Rack PDU\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered Rack PDU, 0U, 32 A — has a sensor port of its own\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858 NetShelter Metered Rack PDU\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered Rack PDU, 0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-10a-c14-in-12-c13-out\"\u003eAP4421 Rack ATS 10 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack ATS, 10 A, C14 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423 Rack ATS 16 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack ATS, 16 A, C20 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424\"\u003eAP4424 Rack ATS 32 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack ATS, 32 A, IEC 309 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNetBotz Rack Monitor 250 (NBRK0250A)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNetBotz Rack Monitor 250, 1U — door, temperature, leak and access monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eLinks open on Schneider Electric's own site. Each one was checked before publication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/AR3100\/apc-netshelter-sx-server-rack-enclosure-42u-black-1991h-x-600w-x-1070d-mm\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for the APC AR3100 (Singapore site) — official product name, characteristics and the full document list including the NetShelter SX user guide 990-2183J\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's own datasheet download links redirect to a host that has served wrong-model files, so for the PDF datasheet or manual as a file for a tender, email sales@sourceit.com.sg quoting the SKU and we will send the correct document.\u003c\/p\u003e\n\u003cp\u003eNeed a compliance declaration, a CAD file or a written quotation for a tender? Contact SourceIT and we will supply it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AR3100\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the AR3100 and the Easy Rack ER6202?\u003c\/h4\u003e\n\u003cp\u003eBoth are 42U, 600 mm wide black cabinets with perforated doors and a 5-year warranty. The AR3100 is 1070 mm deep to the Easy Rack's 1000 mm, has split rear doors, a higher 1364 kg static rating, heavier-gauge doors and the full NetShelter SX accessory ecosystem. The Easy Rack is the value choice for a straightforward server rack; the SX is the choice for a production room that will be worked on and reconfigured for years.\u003c\/p\u003e\n\u003ch4\u003eDoes it arrive assembled?\u003c\/h4\u003e\n\u003cp\u003eYes. The AR3100 ships as a built cabinet on a pallet, 2118 mm high and 144.6 kg. Plan the goods lift and the route; if the crate cannot get through a doorway, unpack at the loading bay and roll the 1991 mm cabinet in on its castors.\u003c\/p\u003e\n\u003ch4\u003eHow much can it carry?\u003c\/h4\u003e\n\u003cp\u003e1364 kg static once levelled on its feet and bolted down with the AR7701 kit, and 1023 kg dynamic when rolled on the castors — which is why an SX can be pre-built off site and wheeled into position loaded.\u003c\/p\u003e\n\u003ch4\u003eWhy split rear doors?\u003c\/h4\u003e\n\u003cp\u003eA split rear door needs about half the swing clearance of a single door, so the cabinet can sit closer to a wall or in a narrower hot aisle and still give full access to the PDUs and power leads at the back.\u003c\/p\u003e\n\u003ch4\u003eWhich PDUs go in the rear channels?\u003c\/h4\u003e\n\u003cp\u003e0U models — the \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552 Rack PDU Basic 0U 16 A\u003c\/a\u003e, \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-32a-230v-ap7553\"\u003eAP7553 Rack PDU Basic 0U 32 A\u003c\/a\u003e, \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853 NetShelter Metered Rack PDU\u003c\/a\u003e and \u003ca href=\"\/products\/apc-easy-rack-pdu-switched-0u-3-phase-22kw-230v-epdu1232s\"\u003eEPDU1232S Easy Rack PDU Switched 0U\u003c\/a\u003e all mount vertically in the SX accessory channels without consuming rack units. 1U and 2U PDUs, the rack ATS models and the NetBotz appliance go on the rails.\u003c\/p\u003e\n\u003ch4\u003eDo I need the bolt-down kit?\u003c\/h4\u003e\n\u003cp\u003eSchneider requires the cabinet to be secured to the floor before equipment is installed, and the AR7701 is the kit designed for the SX frame. For a comms room on a solid slab it is a small cost against a loaded rack tipping during a move or a seismic event.\u003c\/p\u003e\n\u003ch4\u003eCan I bay several AR3100 cabinets together?\u003c\/h4\u003e\n\u003cp\u003eYes — baying hardware is in the box, and the side panels lift off so bayed cabinets share cable routes. Each cabinet still needs its own floor anchoring.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC AR3100 sold by SourceIT comes with local Singapore warranty support and a GST invoice; APC by Schneider Electric prints a 5-year repair-or-replace warranty for the NetShelter SX enclosure, which is the term we pass on.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482612498596,"sku":"AR3100","price":2419.6,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_4f0150f3-cb7b-461c-ad42-61afa61e35d8.jpg?v=1789716344","url":"https:\/\/sourceit.com.sg\/products\/apc-netshelter-sx-42u-600mm-wide-1070mm-deep-server-rack-enclosure-black-ar3100","provider":"SourceIT ","version":"1.0","type":"link"}