{"product_id":"apc-netshelter-rack-ats-1u-16a-230v-2-iec-309-in-1-iec-309-out-ap4422a","title":"APC NetShelter Rack ATS 1U 16A 230V, 2 IEC 309 In, 1 IEC 309 Out","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Rack ATS 1U 16A 230V, 2 IEC 309 In, 1 IEC 309 Out (AP4422A) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e16 A Source Redundancy for a Whole Rack PDU\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Rack ATS AP4422A is the member of Schneider's fifth-generation Rack ATS family built to sit in front of a rack PDU rather than in front of individual servers. Instead of a row of C13 outlets it has a single IEC 60309 16 A outlet, and instead of C20 inlets it has two captive IEC 60309 16 A input cords. Feed those two cords from two independent sources, plug your existing zero-U or 1U PDU into the output, and every single-corded device on that PDU gains a second power path without touching a single equipment cord.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTransfers in 10 ms or Less\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen the preferred source drifts outside tolerance the AP4422A transfers the load to the alternate feed in 10 ms. That is inside the hold-up time of a normal server or network power supply, so the equipment downstream rides through the transfer without rebooting.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDesigned for 230 V Singapore Racks\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRated at 230 V AC nominal with a 207 to 253 V window and 50\/60 Hz operation, the AP4422A runs directly on Singapore mains and delivers up to 3,840 VA at 16 A. IEC 60309 16 A (commando) sockets are the standard 16 A outlet in Singapore comms rooms, so both input cords plug straight into wall or busway sockets or a UPS outlet with no adapters.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFifth-Generation Management: NMC3, Colour LCD, Sensor Port\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AP4422A carries Schneider's Network Management Card 3 as standard, and the NMC\/display module is field-replaceable. Gigabit Ethernet, a secure Web UI, SSH, SNMP v1 and v3, Modbus TCP and EcoStruxure IT integration are all built in, and Schneider includes a one-year Secure NMC System subscription with the unit. The colour LCD shows both sources' voltage and frequency, load in amps, alarms and the preferred source; the Universal I\/O port takes an AP9335T or AP9335TH sensor; and the Link A\/B ports let up to 32 Rack ATS units share a single IP address. In a 1U chassis 236 mm deep, it fits comms cabinets and server racks alike.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP4422A Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Rack Automatic Transfer Switch, 1U, 16A, 230V, 2 IEC309 IN, 1 IEC309 OUT, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP4422A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Rack ATS, fifth generation (AP44XXA series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRack-mount Automatic Transfer Switch (ATS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e1U, 19-inch rack mount, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Subscription\u003c\/td\u003e\n\u003ctd\u003e1-Year Secure Network Management Card subscription\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric); 5-year extended warranty available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connections\u003c\/td\u003e\n\u003ctd\u003eTwo (2) IEC 60309 16 A 2P+E plugs on captive input cords (Source A and Source B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Cord Length\u003c\/td\u003e\n\u003ctd\u003e2.43 m each, two cords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e207 to 253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Current\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Line Current\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003ctd\u003eNot fitted (without circuit breaker) - protection comes from the branch circuit feeding each source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connection\u003c\/td\u003e\n\u003ctd\u003eOne (1) IEC 60309 16 A 2P+E outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Cord Length (as printed by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003e0.91 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Capacity\u003c\/td\u003e\n\u003ctd\u003e3,840 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNot fitted - Schneider states in the AP44XXA user guide that the Rack ATS does not include power surge protection and recommends feeding each source from a double-conversion on-line UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunications \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management Card\u003c\/td\u003e\n\u003ctd\u003eNetwork Management Card 3 (NMC3) integrated as standard; the NMC\/display module is field-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Port\u003c\/td\u003e\n\u003ctd\u003eGigabit Ethernet (10\/100\/1000) with link status LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interfaces\u003c\/td\u003e\n\u003ctd\u003eWeb UI (HTTP\/HTTPS), Command Line Interface (SSH\/SCP, Telnet), SNMP v1 and v3 with traps, Modbus TCP, FTP, Syslog, e-mail notification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Platform\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure IT compatible (alerts and control for one or many ATS units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Port Sharing\u003c\/td\u003e\n\u003ctd\u003eLink A and Link B ports: up to 32 AP44XXA Rack ATS units share one network connection and one IP address; one unit acts as host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003eMicro-USB for local CLI access (cable not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003eUSB-A for firmware upgrade from a USB drive and for the optional APC AP9834 Wi-Fi USB device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Sensor Port\u003c\/td\u003e\n\u003ctd\u003eUniversal I\/O port for the optional AP9335T temperature sensor or AP9335TH temperature\/humidity sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Display\u003c\/td\u003e\n\u003ctd\u003eColour LCD rotating through Source A and B voltage and frequency, load in amps, alarm status and preferred source; Home\/Down\/Select buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource Preference\u003c\/td\u003e\n\u003ctd\u003eSelectable - Source A, Source B, or no preference, from the front panel or remotely\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Sensitivity\u003c\/td\u003e\n\u003ctd\u003eSelectable high or low, with configurable transfer voltage ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware\u003c\/td\u003e\n\u003ctd\u003eNMC3 ATS firmware, flash-upgradeable over the network or from a USB drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e44 x 432 x 236 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e4.21 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight (as printed)\u003c\/td\u003e\n\u003ctd\u003e5.89 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards (as printed by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003eCE; EMC Directive; EN\/IEC 60950-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS \/ REACh\u003c\/td\u003e\n\u003ctd\u003eEU RoHS compliant; REACh declaration available from Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Load Planning\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you plug into it.\u003c\/strong\u003e The AP4422A has one outlet, an IEC 60309 16 A socket, so it is not an outlet strip - it is the redundant feed for something else. In practice that something is a 16 A rack PDU: either one with a captive IEC 60309 16 A plug, or a C20-inlet PDU such as the \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552 zero-U basic PDU\u003c\/a\u003e or the \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B switched PDU\u003c\/a\u003e fed through an AP9876 cord (IEC 60309 16 A plug to C19). The PDU then distributes to the C13 and C19 outlets in the cabinet, so a single ATS in front of a single PDU covers every single-corded device in that rack at once.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoad planning.\u003c\/strong\u003e Rated capacity is 3,840 VA at 16 A. Plan against that figure and the total nameplate current of everything on the downstream PDU, not against the PDU's outlet count. During a failover one source carries the whole load, so both feeds and both upstream breakers must be sized for the full 16 A, not half of it. The AP4422A has no internal circuit breaker; protection comes from the branch circuit feeding each source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e 1U high, 432 mm wide, 236 mm deep. The shallow depth suits wall-mount and comms cabinets as well as full-depth racks. The 1U rack-mount bracket kit and hardware are in the box; front and rear rail segments and a cord retention bracket are optional extras.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeeding it.\u003c\/strong\u003e Both input cords are captive, 2.43 m long and terminated in IEC 60309 16 A 2P+E plugs. Each needs its own IEC 60309 16 A socket: a wall or busway commando socket, the IEC 60309 outlet on a UPS, or a bypass PDU outlet. The two sources must be genuinely independent for the redundancy to mean anything: separate UPS units, or separate breakers on separate risers. Both plugs into one PDU protects against nothing. An on-line UPS such as the \u003ca href=\"\/products\/apc-smart-ups-on-line-3kva-rackmount-2u-230v-8x-c13-2x-c19-iec-srt3000rmxli\"\u003eSmart-UPS SRT 3000VA\u003c\/a\u003e on one feed and mains on the other is the usual small-room arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManagement.\u003c\/strong\u003e The AP4422A carries Schneider's Network Management Card 3 as standard - there is no SmartSlot to populate and no card to buy. You get a Gigabit Ethernet port, a secure Web UI over HTTP\/HTTPS, a CLI over SSH, SNMP v1 and v3 with traps, Modbus TCP for a building management system, Syslog and e-mail alerts, and EcoStruxure IT integration. The NMC\/display module can be swapped in the field, so a damaged card is a spare-part exchange rather than a whole-unit return.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental monitoring.\u003c\/strong\u003e The Universal I\/O port accepts the optional AP9335T temperature sensor or the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH temperature and humidity sensor\u003c\/a\u003e, so a comms cabinet with no other monitoring can report rack temperature through the same IP address as its power switching. Thresholds and alarms are set in the same Web UI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMany units, one IP.\u003c\/strong\u003e Link A and Link B let up to 32 AP44XXA-series Rack ATS units share one network connection; one unit is the host and the rest appear under it in the Web UI and SNMP.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; NetShelter Rack ATS Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC NetShelter Rack ATS (AP4422A) with two captive 2.43 m IEC 60309 16 A input cords\u003c\/li\u003e\n\u003cli\u003e1U rack-mount bracket kit and mounting hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUnlike the C20-inlet models in this family, the AP4422A needs no separate input cords - both are attached. A micro-USB console cable, rail segments and a cord retention bracket are not in the box.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eNetShelter Rack ATS Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-10a-c14-in-12-c13-out\"\u003eAP4421A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 10 A, 2,000 VA\u003c\/td\u003e\n\u003ctd\u003e2 x IEC C14 inlets\u003c\/td\u003e\n\u003ctd\u003e(12) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP4422A (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 16 A, 3,840 VA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2 x IEC 60309 16 A captive cords\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(1) IEC 60309 16 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3,700 VA\u003c\/td\u003e\n\u003ctd\u003e2 x IEC C20 inlets\u003c\/td\u003e\n\u003ctd\u003e(8) C13, (1) C19\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424\"\u003eAP4424A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7,400 VA\u003c\/td\u003e\n\u003ctd\u003e2 x IEC 60309 32 A\u003c\/td\u003e\n\u003ctd\u003e(16) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eRack PDUs for the AP4422A Output\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AP4422A's single IEC 60309 16 A outlet feeds one 16 A rack PDU. A PDU with a captive IEC 60309 16 A plug connects directly; a C20-inlet PDU connects through an AP9876 power cord (IEC 60309 16 A plug to C19, 2.5 m). Two C20-inlet PDUs from the SourceIT catalogue:\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP7552\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAPC NetShelter Basic Rack PDU, Zero U, 16A, 230V, (20) C13 \u0026amp; (4) C19, C20 inlet\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP7921B\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAPC NetShelter Switched Rack PDU, 1U, 16A, 230V, (8) C13, C20 cord\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335TH\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAPC Temperature \u0026amp; Humidity Sensor\u003c\/a\u003e - plugs into the Universal I\/O port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335T\u003c\/td\u003e\n\u003ctd\u003eAPC Temperature Sensor - plugs into the Universal I\/O port; ask us for availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9834\u003c\/td\u003e\n\u003ctd\u003eAPC Wi-Fi USB device for cable-free setup and management via the USB-A port; ask us for availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric document landing pages and product page for the AP44XXA-series Rack ATS. Links open in a new tab.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct overview and specifications\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-91723_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eNetShelter Rack ATS AP4422A Overview and Specifications (990-91723_EN)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-91718_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eRack ATS with Network Management Card 3 User Guide AP44XXA (990-91718_EN)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical brochure\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/sg\/en\/download\/document\/AP44xxA_Technical_Brochure\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC NetShelter Rack ATS Fifth Generation AP44xxA Series Technical Brochure\u003c\/a\u003e — Singapore site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric product page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/AP4422A\/apc-netshelter-rack-automatic-transfer-switch-1u-16a-230v-2-iec309-in-1-iec309-out-50-60hz\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC AP4422A on se.com\u003c\/a\u003e — Singapore site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eSchneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eAP4422A\u003c\/strong\u003e and we will send you the current PDF datasheet and user guide directly.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP4422A\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy does the AP4422A have only one outlet?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBecause it is designed to feed a rack PDU, not individual devices. The single IEC 60309 16 A outlet feeds one 16 A PDU - directly if the PDU has a commando plug, or through an AP9876 cord for a C20-inlet PDU such as the \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552\u003c\/a\u003e or \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e - and that PDU then serves the whole cabinet. If you would rather plug servers straight into the ATS, the \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423A\u003c\/a\u003e has eight C13 and one C19 at the same 16 A rating, and the \u003ca href=\"\/products\/apc-rack-ats-230v-10a-c14-in-12-c13-out\"\u003eAP4421A\u003c\/a\u003e has twelve C13 at 10 A.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat do the two input cords plug into?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEach is 2.43 m long and ends in an IEC 60309 16 A 2P+E plug, the blue commando plug. You need two IEC 60309 16 A sockets from two independent sources: for example the IEC 60309 outlet on a UPS for Source A and a wall socket on a separate breaker for Source B. Because the cords are captive, there are no input cords to order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes the AP4422A have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider states this plainly in the AP44XXA user guide (990-91718): the Rack ATS does not include power surge protection, and it recommends connecting each Rack ATS source to a double-conversion on-line UPS. If surge and dip protection is what you actually need, an on-line UPS such as the Smart-UPS SRT range in front of the ATS is the right answer, and it also gives the ATS a genuinely independent second source.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs network management built in, or do I need to buy a card?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBuilt in. The AP4422A ships with Network Management Card 3 integrated - Gigabit Ethernet, Web UI over HTTP\/HTTPS, SSH, SNMP v1 and v3, Modbus TCP and EcoStruxure IT support are all standard, and Schneider includes a one-year Secure NMC System subscription. You do not buy a card for it. If the module is ever damaged it can be replaced in the field rather than sending the whole switch away.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan it monitor rack temperature and humidity?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes, with an optional sensor. Plug an AP9335T (temperature) or \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH (temperature and humidity)\u003c\/a\u003e into the Universal I\/O port and the readings, thresholds and alarms appear in the same Web UI and SNMP tree as the power data. No NetBotz appliance is needed for a single-cabinet site.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow fast does it transfer, and will my servers notice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSchneider prints a 10 ms transfer time for the AP4422A. That is inside the hold-up time of a normal server or network power supply, so equipment downstream of the PDU generally rides through without restarting. High sensitivity reacts sooner to a marginal source; low sensitivity tolerates more deviation before acting, which helps on a generator feed.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does the AP4422A differ from the AP4422 it replaces?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe electrical side is unchanged: same 16 A, 230 V rating, same captive IEC 60309 input cords and the same IEC 60309 outlet, so the AP4422A drops into an existing AP4422 installation without rewiring. What Schneider changed is the management module. The AP4422A moves from Network Management Card 2 to Network Management Card 3, and that card and its display are now field-replaceable. It adds a Universal I\/O port for a sensor, Link A\/B ports for sharing one IP address across up to 32 units, Gigabit Ethernet in place of 10\/100, a colour LCD, micro-USB console and USB-A ports, Modbus TCP, updated security and EcoStruxure IT integration. The standard warranty stays at 2 years.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does it compare with the AP4421A, AP4423A and AP4424A?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-10a-c14-in-12-c13-out\"\u003eAP4421A\u003c\/a\u003e: 10 A, 2,000 VA, C14 inlets, twelve C13, 1U. AP4422A (this listing): 16 A, 3,840 VA, captive IEC 60309 16 A inputs, one IEC 60309 16 A outlet, 1U - the one for feeding a PDU. \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423A\u003c\/a\u003e: 16 A, 3,700 VA, C20 inlets, eight C13 plus one C19, 1U. \u003ca href=\"\/products\/apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424\"\u003eAP4424A\u003c\/a\u003e: 32 A, 7,400 VA, IEC 60309 32 A inputs, sixteen C13 plus two C19, 2U. Pick on total current draw first, then on whether you want the ATS to feed a PDU or to be the outlet strip itself.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Rack ATS AP4422A sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs the AP4422A with a 2-year manufacturer warranty, and a 5-year extended warranty is offered by Schneider - ask us to quote it with the unit.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/iunRiD8YB3s\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482595098788,"sku":"AP4422A","price":1771.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_d6d44af5-a347-458b-90ab-9e5a125f3f3f.jpg?v=1789713068","url":"https:\/\/sourceit.com.sg\/products\/apc-netshelter-rack-ats-1u-16a-230v-2-iec-309-in-1-iec-309-out-ap4422a","provider":"SourceIT ","version":"1.0","type":"link"}