{"product_id":"apc-netshelter-power-cord-kit-5-ea-c13-to-c14-0-6m-ap9890","title":"APC NetShelter Power Cord Kit 5 Pack IEC C13 to C14 0.6m Black","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Power Cord Kit (5 ea), IEC C13 to C14, 0.6 m (AP9890) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eFive Short Cords for a Tidy Rack\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Power Cord Kit AP9890 is a pack of five 0.6 m IEC 60320 C13 to C14 cords. Each has a C14 plug for a PDU, UPS or Rack ATS outlet and a C13 connector for the inlet on a server, switch or appliance. The point of 0.6 m is that a zero-U PDU on the rear rail is never more than a few hundred millimetres from the equipment beside it - a 1.8 m equipment cord in that position is 1.2 m of slack to coil, tie and eventually snag.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRated for the Full C13\/C14 Coupler\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSchneider prints the kit at 230 V AC. IEC 60320 rates the C13\/C14 coupler at 10 A, which is also the limit of the C14 inlet on any device the cord feeds, so one cord per device is always within rating. Schneider lists the kit for use with APC rack-mount PDUs and outlet strips, MasterSwitch units, Rack ATS, UPS and separate branch circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Short Cords Matter\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eExcess cable in the rear of a rack blocks airflow from the equipment exhaust, hides the PDU's outlet numbering, and is the thing that gets pulled when someone slides a server out on its rails. Five 0.6 m cords replace five coils of surplus with five straight runs, which also makes it obvious which outlet feeds which device when you are power-cycling a hung box over the PDU's web interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eVDE Certified, Supplied Locally in Singapore with GST Invoice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSchneider lists the AP9890 as VDE certified and EU RoHS compliant, with a 2-year repair-or-replace warranty. SourceIT supplies it with a GST invoice and local Singapore warranty support; order one kit per five devices on a zero-U PDU and the rack rear stays readable.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP9890 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP9890\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003ePower Cord Kit (5 ea), C13 to C14, 0.6m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Power Cords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower cord kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity per Pack\u003c\/td\u003e\n\u003ctd\u003e5 cords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric) - repair or replace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eYes - supplied and supported locally by SourceIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eConnectors \u0026amp; Electrical\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug End\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 (3-pin male)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector End\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C13 (3-pin female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 60320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003eNot printed by Schneider Electric for this kit; the IEC 60320 C13\/C14 coupler is a 10 A connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e0.6 m each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Gauge\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this part\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (kit)\u003c\/td\u003e\n\u003ctd\u003e0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e0U - not rack-mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards (as printed)\u003c\/td\u003e\n\u003ctd\u003eVDE certified; EU RoHS compliant; REACh - free of substances of very high concern above threshold; contains halogen above thresholds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it goes.\u003c\/strong\u003e C14 plug into a C13 outlet on a PDU, UPS, Rack ATS or bypass PDU; C13 connector into the C14 inlet on the equipment. Schneider's own compatibility note lists APC rack-mount PDUs and outlet strips, MasterSwitch, Automatic Transfer Switches, UPS and separate branch circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest with a zero-U PDU.\u003c\/strong\u003e The 0.6 m length is sized for a vertical PDU on the rear rail with the equipment inlets a few hundred millimetres away: \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552 zero-U basic PDU (20 C13, 4 C19, C20 inlet)\u003c\/a\u003e, \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853 metered zero-U PDU (36 C13, 6 C19)\u003c\/a\u003e and the \u003ca href=\"\/products\/apc-easy-rack-pdu-basic-1u-1-phase-2-3kw-230v-epdu1010b-sch\"\u003eEPDU1010B-SCH Easy Rack PDU (C14 inlet)\u003c\/a\u003e. It also suits a 1U PDU or a Rack ATS such as the \u003ca href=\"\/products\/apc-rack-ats-230v-10a-c14-in-12-c13-out\"\u003eAP4421A Rack ATS (C14 in, 12 C13 out)\u003c\/a\u003e or \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423A Rack ATS (C20 in, 8 C13 and 1 C19 out)\u003c\/a\u003e feeding the two or three devices immediately above and below it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eToo short for bottom-to-top runs.\u003c\/strong\u003e From a UPS or 1U PDU at the bottom of a 42U rack to a device near the top, 0.6 m will not reach - that is what the 2.5 m AP9870 is for. Mix the two: short cords for the devices near the PDU, long cords for the outliers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRating.\u003c\/strong\u003e One cord per device. A C14 inlet cannot draw more than the C13\/C14 coupler's 10 A rating, so any single device is within limits. Do not use a cord from this kit to feed a multi-way strip.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLocking alternative.\u003c\/strong\u003e The \u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAP8704S-WW locking C13 to C14 cord kit, 6 x 1.2 m\u003c\/a\u003e gives six locking cords at 1.2 m for outlets that must not be knocked loose. Standard cords like the AP9890 rely on the connector's own friction fit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIEC Connector Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRack power cords are named by the IEC 60320 coupler on each end. The socket side of a coupler is the odd number and the pin side is the even number, so a C14 plug goes into a C13 outlet and a C19 connector goes onto a C20 inlet.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFound on\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMates with\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC13 (socket)\u003c\/td\u003e\n\u003ctd\u003eCord end that goes into equipment; PDU, UPS and ATS outlets\u003c\/td\u003e\n\u003ctd\u003eC14\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC14 (pins)\u003c\/td\u003e\n\u003ctd\u003eCord plug; inlet on servers, switches, 10 A PDUs and UPS units\u003c\/td\u003e\n\u003ctd\u003eC13\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC19 (socket)\u003c\/td\u003e\n\u003ctd\u003eCord end for high-power equipment; outlets on larger UPS, ATS and PDUs\u003c\/td\u003e\n\u003ctd\u003eC20\u003c\/td\u003e\n\u003ctd\u003e16 A (IEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC20 (pins)\u003c\/td\u003e\n\u003ctd\u003eCord plug; inlet on 16 A PDUs, Rack ATS and high-power servers\u003c\/td\u003e\n\u003ctd\u003eC19\u003c\/td\u003e\n\u003ctd\u003e16 A (IEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEC 60309 16 A 2P+E (blue commando)\u003c\/td\u003e\n\u003ctd\u003eWall and busway sockets, UPS and bypass outlets, captive PDU and ATS input cords\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 16 A socket\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eNot one of these is a BS 1363 (Type G) wall plug. In a Singapore rack the mains connection is normally made once, at the UPS or PDU input, and everything downstream is IEC to IEC.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; APC NetShelter Power Cord Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e5 x APC NetShelter Power Cord, IEC C13 to C14, 0.6 m (AP9890 kit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAPC NetShelter Power Cords — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese five NetShelter cords cover the common rack connections. Each is a separate listing; the one you are reading is in bold.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical use\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9870\u003c\/td\u003e\n\u003ctd\u003eIEC C13 to C14\u003c\/td\u003e\n\u003ctd\u003e10 A, 250 V\u003c\/td\u003e\n\u003ctd\u003e2.5 m\u003c\/td\u003e\n\u003ctd\u003eEquipment cord: PDU, UPS or ATS C13 outlet to a C14 inlet on a server or switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9876\u003c\/td\u003e\n\u003ctd\u003eIEC C19 to IEC 60309 16 A plug\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003ctd\u003e2.5 m\u003c\/td\u003e\n\u003ctd\u003eInput cord: 16 A commando socket to a C20-inlet PDU, ATS or UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9877\u003c\/td\u003e\n\u003ctd\u003eIEC C19 to C20\u003c\/td\u003e\n\u003ctd\u003e16 A (IEC 60320)\u003c\/td\u003e\n\u003ctd\u003e2.0 m\u003c\/td\u003e\n\u003ctd\u003eJumper: UPS or ATS C19 outlet to a C20-inlet PDU, ATS or high-power server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9878\u003c\/td\u003e\n\u003ctd\u003eIEC C19 to C14\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003ctd\u003e2.0 m\u003c\/td\u003e\n\u003ctd\u003eAdapter cord: C13 outlet to a C20-inlet device at 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP9890 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC C13 to C14, 5 cords\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 A (IEC 60320 coupler rating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.6 m\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eShort equipment cords for tidy in-rack runs from a zero-U PDU\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Alternative\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAP8704S-WW locking C13 to C14 cord kit, 6 x 1.2 m\u003c\/a\u003e - locking C13 connectors that cannot be nudged out of a PDU outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP9890. Links open in a new tab.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric product page\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/product\/AP9890\/power-cord-kit-5-ea-c13-to-c14-0-6m\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC AP9890 Power Cord Kit (5 ea), C13 to C14, 0.6 m on se.com\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eSchneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eAP9890\u003c\/strong\u003e and we will send you the current PDF datasheet and user guide directly.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP9890\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eHow many cords are in the kit?\u003c\/h3\u003e\n\u003cp\u003eFive, each 0.6 m, each C13 to C14. Schneider sells them as a kit rather than singly; for a rack with twelve devices on a zero-U PDU, order three kits.\u003c\/p\u003e\n\u003ch3\u003eIs 0.6 m really long enough?\u003c\/h3\u003e\n\u003cp\u003eFor equipment beside a zero-U PDU on the rear rail, yes - the inlet is typically 200 to 400 mm from the nearest outlet. For a device several U away from a horizontal PDU, or anything fed from a UPS at the bottom of the rack, use the 2.5 m AP9870 instead. Most tidy racks use both.\u003c\/p\u003e\n\u003ch3\u003eHow much current can each cord carry?\u003c\/h3\u003e\n\u003cp\u003eSchneider does not print a current figure for this kit, but the IEC 60320 C13\/C14 coupler it uses is a 10 A connector, the same as every C14 inlet it will plug into. One cord per device is always within rating.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between this and the AP8704S-WW kit?\u003c\/h3\u003e\n\u003cp\u003eLength, count and locking. The AP9890 is five non-locking 0.6 m cords. The \u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAP8704S-WW locking C13 to C14 cord kit, 6 x 1.2 m\u003c\/a\u003e is six locking 1.2 m cords whose C13 end latches into the outlet. Choose the locking kit where accidental disconnection is a real risk; choose the AP9890 for short runs where neatness is the goal.\u003c\/p\u003e\n\u003ch3\u003eCan I use these on a Rack ATS?\u003c\/h3\u003e\n\u003cp\u003eYes, on the output side. Schneider lists Automatic Transfer Switches among the intended hosts, and the \u003ca href=\"\/products\/apc-rack-ats-230v-10a-c14-in-12-c13-out\"\u003eAP4421A Rack ATS (C14 in, 12 C13 out)\u003c\/a\u003e and \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423A Rack ATS (C20 in, 8 C13 and 1 C19 out)\u003c\/a\u003e have C13 outlets. They are not ATS input cords.\u003c\/p\u003e\n\u003ch3\u003eWill they work with non-APC PDUs and servers?\u003c\/h3\u003e\n\u003cp\u003eYes. IEC 60320 C13 and C14 are the universal IT connectors; any PDU with C13 outlets and any device with a C14 inlet accepts them, whatever the brand. The reason to buy the APC kit rather than a loose bag of cords is consistency: five identical black 0.6 m cords from a VDE-certified range, with a part number your purchasing team can reorder and a manufacturer warranty behind them.\u003c\/p\u003e\n\u003ch3\u003eWill this plug into a Singapore wall socket?\u003c\/h3\u003e\n\u003cp\u003eNo. Each AP9890 cord has an IEC C14 plug and an IEC C13 connector. Singapore wall sockets are BS 1363 (Type G), and none of the connectors on this cord are BS 1363. The normal Singapore arrangement is an IEC-fed rack PDU or a UPS with IEC outlets, with cords like this one running from those outlets to the equipment. If you need a BS 1363 to IEC lead for a UPS or PDU input, ask us separately.\u003c\/p\u003e\n\u003ch3\u003eDoes it come with a Singapore warranty?\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC AP9890 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs its NetShelter power cords with a 2-year repair-or-replace manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482611351716,"sku":"AP9890","price":49.68,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_f19f7d07-b173-41e0-b056-1c07041987d9.jpg?v=1789715862","url":"https:\/\/sourceit.com.sg\/products\/apc-netshelter-power-cord-kit-5-ea-c13-to-c14-0-6m-ap9890","provider":"SourceIT ","version":"1.0","type":"link"}