{"product_id":"apc-netshelter-metered-rack-pdu-0u-16a-230v-18-c13-2-c19-iec-309-cord-ap8858eu3","title":"APC NetShelter Metered Rack PDU 0U 16A 230V 18 C13 2 C19 IEC 309 Cord","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Metered Rack PDU, 0U, 1 Phase, 3.7kW 230V 16A, 18 C13 \u0026amp; 2 C19 Outlets, IEC 309 Cord (AP8858EU3) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eThe AP8858 With a 16 A Commando Cord in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Metered Rack PDU AP8858EU3 is the cord-included version of the \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e: the same 902 mm half-height 0U strip with eighteen IEC C13 and two IEC C19 outlets, rated 16 A and 3.7 kW at 230 V, but supplied with a 3 m locking input cord that ends in an IEC 60309 16 A 2P+E plug. If your rack or row PDU presents 16 A commando sockets - common in Singapore data centres and colocation cages - this is the part number to order, and nothing else needs buying.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDevice-Level Metering to ±3%, With Energy Tracking\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AP8858EU3 measures amps, volts, kW and kWh for the whole strip to ±3% accuracy and reports them over the network, so you can plan capacity, balance A and B feeds and track energy for scope 1 and scope 3 emissions reporting. Schneider positions it for colocation and remote data centre operators, and it is the sensible choice for a Singapore branch or server room where you want to see the rack load without paying for per-outlet metering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eNetwork Management Built In\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWeb, SNMP, Telnet and SSH access are standard, reporting into EcoStruxure IT and other platforms, and Schneider includes a one-year Secure Network Management Card subscription. Nothing needs to be fitted - the management is on the strip - and a serial configuration cable is in the box for first setup.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eA 902 mm Strip That Fits Mid-Height Cabinets\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAt 902 mm long, 56 mm wide and 44 mm deep and 2.93 kg, this is a half-height 0U unit. It is the metered strip that fits a 24U or 27U enclosure with a vertical channel, and in a 42U rack it leaves room in the channel for a second strip on the B feed. Rack mounting brackets are supplied.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP8858EU3 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Metered Rack PDU, 0U, 1 phase, 3.7kW 230V 16A, 18 C13 and 2 C19 outlets, IEC 309 cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP8858EU3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMetered Rack Power Distribution Unit (PDU), 2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eZero U (0U), vertical side mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 16 A 2P+E - supplied 3 m locking input cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e200 V, 208 V, 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceptable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e16 A per phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacity\u003c\/td\u003e\n\u003ctd\u003e3,700 VA (3.7 kW at 230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eEighteen (18) IEC 60320 C13 and two (2) IEC 60320 C19 - 20 outlets total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eNot fitted - the 16 A input is the limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMetering, Switching \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eDevice level - current, power, voltage and energy for the whole strip. Not metered per outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3% (amps, volts, kW, kWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd\u003eNot fitted - this is a Metered model, not a Switched one\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eBuilt in as standard - no separate card required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interfaces\u003c\/td\u003e\n\u003ctd\u003eWeb, SNMP, Telnet, SSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Platform\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure IT and other platforms. A one-year Secure Network Management Card subscription is included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Ports\u003c\/td\u003e\n\u003ctd\u003eSerial configuration port (cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided - no surge suppression is specified for this product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e902 x 56 x 44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e2.93 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e4.92 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eVertical side mount; rack mounting brackets included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 15,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 60950, IEC 60950, METI Denan, UL 60950-1, VDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS \/ REACh\u003c\/td\u003e\n\u003ctd\u003eRoHS compliant; REACh - no substances of very high concern; Battery Directive compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Rack Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Eighteen IEC C13 outlets for C14-corded servers, switches and appliances, and two IEC C19 outlets for C20-corded storage or a larger switch. Twenty outlets is plenty for a mid-height cabinet or one feed of a full-height rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoad planning.\u003c\/strong\u003e 16 A total, 3.7 kW at 230 V. The device-level meter shows you the aggregate load to ±3 percent, so you can watch the headroom as you add equipment and set an alarm threshold before the limit. For a rack of dual-PSU servers, run two of these on A and B feeds or step up to the 32 A \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeeding it.\u003c\/strong\u003e The supplied 3 m locking cord ends in an IEC 60309 16 A 2P+E plug, so the rack needs a 16 A commando socket - on a row PDU, a busway tap-off or a fixed outlet. If your supply is a C19 outlet on a UPS instead, order the \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e, which has a bare C20 inlet, and add a C19-to-C20 lead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e A 0U strip 902 mm long, 56 mm wide and 44 mm deep, weighing 2.93 kg - a half-height unit that fits a 24U or 27U enclosure with a vertical channel and takes up about half the channel in a 42U rack. In a short cabinet without a channel, the 2U \u003ca href=\"\/products\/apc-rack-pdu-metered-2u-32a-230v-12-c13-4-c19\"\u003eAP7822B\u003c\/a\u003e is the horizontal metered alternative.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManagement and sensors.\u003c\/strong\u003e Web, SNMP, Telnet and SSH are built in with EcoStruxure IT reporting and a one-year Secure NMC subscription. The 2G Metered range supports an APC environmental sensor such as the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH\u003c\/a\u003e; ask us to confirm the sensor for this part number when you order. The AP9640 and AP9641 cards we sell are Smart-UPS accessories and are not used with this PDU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it does not do.\u003c\/strong\u003e No outlet switching - you cannot power-cycle a device remotely from this PDU; that is the switched range, such as the \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e or the per-outlet AP8659. No per-outlet metering. And no surge protection, which is a UPS function.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Metered and Switched Rack PDU Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC NetShelter Metered Rack PDU (AP8858EU3)\u003c\/li\u003e\n\u003cli\u003e3 m locking input power cord, IEC 60309 16 A 2P+E plug\u003c\/li\u003e\n\u003cli\u003eRack mounting brackets\u003c\/li\u003e\n\u003cli\u003eSerial configuration cable\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003cli\u003eSafety guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMetered \u0026amp; Switched Rack PDU Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 10 A, 2.3 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C14 inlet, 2.4 m cord\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, 2.4 m cord\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, no cord\u003c\/td\u003e\n\u003ctd\u003e(18) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 902 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP8858EU3 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMetered\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 16 A, 3.7 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3 m locking cord, IEC 60309 16 A plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(18) C13, (2) C19\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0U, 902 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPDU1116M\u003c\/td\u003e\n\u003ctd\u003eMetered (Easy Rack PDU)\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 16 A cord, 3 m\u003c\/td\u003e\n\u003ctd\u003e(18) C13, (3) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 902 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-metered-2u-32a-230v-12-c13-4-c19\"\u003eAP7822B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(12) C13, (4) C19\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(36) C13, (6) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,791 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8659\u003c\/td\u003e\n\u003ctd\u003eMetered-by-Outlet + Switched\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet\u003c\/td\u003e\n\u003ctd\u003e(21) C13, (3) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,829 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Sensor (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335TH\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAPC Temperature \u0026amp; Humidity Sensor\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eAPC also makes a temperature-only probe, the AP9335T. We do not hold it as a stock line - ask us and we will quote it.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP8858EU3. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/AP8858EU3\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric AP8858EU3 product page (Singapore)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/in\/en\/download\/document\/990-3436_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Metered Rack PDU AP8858EU3 - Overview and Specifications (990-3436_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's own datasheet download links redirect to a host that has served wrong-model files, so email sales@sourceit.com.sg quoting the SKU for the PDF and we will send you the correct document.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP8858EU3\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the difference between the AP8858EU3 and the AP8858?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe cord. Both are the same 902 mm metered strip - eighteen C13, two C19, 16 A, 3.7 kW, built-in network management. The AP8858EU3 ships with a 3 m locking input cord ending in an IEC 60309 16 A 2P+E commando plug. The \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e ships with a bare C20 inlet and no cord, for feeding from a C19 outlet on a UPS. Choose on what socket your rack provides.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs it metered per outlet?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. The AP8858EU3 meters at device level - amps, volts, kW and kWh for the whole strip, to ±3% - and reports over the network. If you need a reading for each outlet, the AP8659 is the per-outlet metered and switched unit at the same 16 A rating.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat supply does it need?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA 16 A IEC 60309 2P+E commando socket - the blue three-pin connector - on a row PDU, busway or fixed outlet. The 3 m locking cord is in the box, so there is nothing else to buy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan I monitor temperature and humidity through it?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 2G Metered range supports APC environmental sensors such as the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH\u003c\/a\u003e. Ask us to confirm the sensor port for this part number when you order and we will include the right sensor on the quote.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider's specification guide for the AP8858EU3 has no surge section, joule rating or clamping figure. Surge and sag protection is a UPS function.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan it switch outlets off remotely?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo - Metered means measurement, not control. To power-cycle a hung device remotely, look at the \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e in 1U or the per-outlet AP8659 in 0U.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does it compare with the Easy Rack PDU EPDU1116M?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBoth are 902 mm, 16 A, 3.7 kW metered strips on a 3 m IEC 60309 cord. The EPDU1116M has one more C19 outlet, an LCD and a one-year warranty and is the value option. The AP8858EU3 is the NetShelter 2G platform with SSH and Telnet, a two-year warranty, the Secure NMC subscription and EcoStruxure IT reporting. For a colocation or managed environment we would take the AP8858EU3; for a branch cabinet the EPDU1116M is usually enough.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Metered Rack PDU AP8858EU3 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs the AP8858EU3 with a 2-year manufacturer warranty.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482588217508,"sku":"AP8858EU3","price":754.4,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_0a10e57c-196b-4cc3-9258-3ce844554bd4.jpg?v=1789712211","url":"https:\/\/sourceit.com.sg\/products\/apc-netshelter-metered-rack-pdu-0u-16a-230v-18-c13-2-c19-iec-309-cord-ap8858eu3","provider":"SourceIT ","version":"1.0","type":"link"}