{"product_id":"apc-netshelter-metered-by-outlet-switched-rack-pdu-2g-0u-32a-230v-21-c13-3-c19-ap8653","title":"APC NetShelter Metered-by-Outlet Switched Rack PDU 0U 32A 230V 24 Outlets","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Metered-by-Outlet with Switching Rack PDU, 2G, 0U, 32A, 230V, 21 C13 \u0026amp; 3 C19 Outlets, IEC 309 Cord (AP8653) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003ePer-Outlet Metering and Per-Outlet Switching on One 32 A Strip\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Metered-by-Outlet with Switching Rack PDU AP8653 is the top of the 2G single-phase range: every one of its twenty-four outlets - twenty-one IEC C13 and three IEC C19 - is individually metered and individually switchable over the network. You see exactly what each server draws, and you can power-cycle any one of them from a browser without walking to the rack. Schneider's earlier catalogue name for this unit was \"Rack PDU 2G, Switched Plus\"; it is the same product.\u003c\/p\u003e\n\u003cp\u003eFor a colocation cage, a hosting provider billing by the kilowatt-hour, or a Singapore data centre that needs to prove which rack is drawing what, per-outlet measurement to ±3% is the feature that justifies the price over a bank-metered strip.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e32 A and 7.4 kW on a Captive IEC 60309 Cord\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInput is a 3 m attached cord ending in an IEC 60309 32 A 2P+E plug - the blue commando connector - and Schneider rates the strip at 7,400 VA. That needs a 32 A commando socket on a dedicated circuit in the rack, which is a fixed electrical installation; budget for the electrician if it is not already there. In return you get enough capacity to run a full rack of dual-PSU servers from one strip.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eNetwork Management Built In, With a Sensor Port and LCD\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWeb, SNMP, Telnet and SSH access are standard, with reporting into EcoStruxure IT. A local LCD shows current, power and voltage at the strip, a port takes an APC temperature or temperature and humidity sensor, and a serial configuration cable and CAN terminator are in the box. Alarm thresholds warn you before a circuit overloads, and power-on sequencing delays stop a rack full of servers starting at once after an outage.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eA Full-Height 0U Strip - Measure Your Rack First\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis is a 1,829 mm vertical strip, 56 mm wide and 51 mm deep, weighing 8.23 kg. It is designed for a full-height 42U enclosure and mounts toolless in the rear vertical channel, consuming no rack units. The outlets accept APC locking input cords, so a cable cannot be nudged out of its socket during a rack tidy.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP8653 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Metered-by-Outlet with Switching Rack PDU, 2G, 0U, 32A, 230V, 21 C13 and 3 C19 outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP8653\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMetered-by-Outlet with Switching Rack Power Distribution Unit (PDU), 2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eZero U (0U), vertical side mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 32 A 2P+E attached cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e200 V, 208 V, 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceptable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e220-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacity\u003c\/td\u003e\n\u003ctd\u003e7,400 VA (7.4 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eTwenty-one (21) IEC 60320 C13 and three (3) IEC 60320 C19 - 24 outlets total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Banks\u003c\/td\u003e\n\u003ctd\u003eTwo 16 A banks, each with its own overcurrent protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Locking\u003c\/td\u003e\n\u003ctd\u003eCompatible with APC locking input cords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMetering, Switching \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003ePer outlet - current, power and voltage for each of the 24 outlets, plus device level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3% (amps, volts, kW, kWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd\u003eIndividual on\/off control of every outlet over the network, with power sequencing delays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Display\u003c\/td\u003e\n\u003ctd\u003eLCD showing current, power and voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eBuilt in as standard - no separate card required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interfaces\u003c\/td\u003e\n\u003ctd\u003eWeb, SNMP, Telnet, SSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Platform\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure IT and other platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Ports\u003c\/td\u003e\n\u003ctd\u003eSerial configuration port, CAN port (terminator supplied), environmental sensor port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Sensors\u003c\/td\u003e\n\u003ctd\u003eAPC temperature or temperature and humidity sensor, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided - no surge suppression is specified for this product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e1,829 x 56 x 51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e8.23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e10.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eToolless vertical mounting; rack mounting brackets included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 15,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eVDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS \/ REACh\u003c\/td\u003e\n\u003ctd\u003eRoHS compliant with exemptions; REACh - free of substances of very high concern above the threshold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Rack Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Twenty-one IEC C13 outlets for C14-corded servers, switches and appliances, plus three IEC C19 outlets for C20-corded blade chassis, storage shelves and core switches. Twenty-four outlets is enough to cable most full-height racks from one strip, and every outlet accepts APC locking input cords.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoad planning and banks.\u003c\/strong\u003e 32 A input, 7,400 VA total, split across two 16 A banks. Because every outlet is metered you can see which bank is heavier and move a server across before it trips, and the alarm thresholds let the PDU tell you before you get there. Twenty-four outlets on 7.4 kW is modest per-outlet draw - the sockets are there for reach, not so every one can pull its maximum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e A 0U vertical strip 1,829 mm long, 56 mm wide and 51 mm deep, weighing 8.23 kg - a full-height unit that needs a 42U enclosure with a rear vertical channel. It is slightly longer than the 1,791 mm \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e. In a short cabinet the 2U \u003ca href=\"\/products\/apc-rack-pdu-metered-2u-32a-230v-12-c13-4-c19\"\u003eAP7822B\u003c\/a\u003e gives the same 32 A supply horizontally, though without per-outlet metering or switching.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeeding it.\u003c\/strong\u003e A captive 3 m IEC 60309 32 A 2P+E commando cord. The rack needs a matching 32 A commando socket on a dedicated circuit. If the site only has 16 A supplies, the AP8659 is the same per-outlet metered and switched unit at 16 A through a C20 inlet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManagement and sensors.\u003c\/strong\u003e Web, SNMP, Telnet and SSH built in, reporting into EcoStruxure IT, with an LCD at the strip. The sensor port takes an APC temperature probe or the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH\u003c\/a\u003e temperature and humidity sensor - worth adding in Singapore, where a failed cooling unit turns into a thermal problem within minutes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it does not do.\u003c\/strong\u003e No surge protection - that is a UPS function. And no battery: a switched PDU controls power, it does not store it, so a UPS upstream is still required for ride-through. The AP9640 and AP9641 cards we sell are Smart-UPS accessories and have nothing to do with this PDU; its network management is built in.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Metered and Switched Rack PDU Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC NetShelter Metered-by-Outlet with Switching Rack PDU (AP8653) with attached 3 m IEC 60309 32 A input cord\u003c\/li\u003e\n\u003cli\u003eRack mounting brackets\u003c\/li\u003e\n\u003cli\u003eCAN port terminator\u003c\/li\u003e\n\u003cli\u003eSerial configuration cable\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003cli\u003eSafety guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMetered \u0026amp; Switched Rack PDU Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 10 A, 2.3 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C14 inlet, 2.4 m cord\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, 2.4 m cord\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, no cord\u003c\/td\u003e\n\u003ctd\u003e(18) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 902 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8858EU3\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 16 A locking cord, 3 m\u003c\/td\u003e\n\u003ctd\u003e(18) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 902 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-metered-2u-32a-230v-12-c13-4-c19\"\u003eAP7822B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(12) C13, (4) C19\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(36) C13, (6) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,791 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8659\u003c\/td\u003e\n\u003ctd\u003eMetered-by-Outlet + Switched\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet\u003c\/td\u003e\n\u003ctd\u003e(21) C13, (3) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,829 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP8653 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMetered-by-Outlet + Switched\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 32 A, 7.4 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCaptive IEC 60309 32 A cord, 3 m\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(21) C13, (3) C19\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0U, 1,829 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPDU9953\u003c\/td\u003e\n\u003ctd\u003eSwitched (9000 series)\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord, 3 m\u003c\/td\u003e\n\u003ctd\u003e(21) C13, (3) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,829 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor three-phase racks, the \u003ca href=\"\/products\/apc-netshelter-rack-pdu-advanced-metered-3phase-apdu10450me\"\u003eAPDU10450ME\u003c\/a\u003e and the Easy Rack PDU \u003ca href=\"\/products\/apc-easy-rack-pdu-switched-0u-3-phase-22kw-230v-epdu1232s\"\u003eEPDU1232S\u003c\/a\u003e are the equivalent managed strips.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Sensor (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335TH\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAPC Temperature \u0026amp; Humidity Sensor\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eAPC also makes a temperature-only probe, the AP9335T. We do not hold it as a stock line - ask us and we will quote it.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP8653. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/AP8653\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric AP8653 product page (Singapore)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-3456_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Rack PDU AP8653 - Overview and Specifications (990-3456_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's own datasheet download links redirect to a host that has served wrong-model files, so email sales@sourceit.com.sg quoting the SKU for the PDF and we will send you the correct document.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP8653\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eIs this the \"Rack PDU 2G, Switched Plus\" model?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. AP8653 was catalogued as Rack PDU 2G, Switched Plus, Zero U, 32A, 230V; Schneider now lists it as the NetShelter Metered-by-Outlet with Switching Rack PDU, 2G, 0U, 32A, 230V. Same part number, same product - twenty-one C13 and three C19 outlets, each metered and each switchable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat does metered-by-outlet actually give me over bank metering?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA current, power and energy reading for every individual outlet, to ±3%, rather than one figure per breaker bank. That lets you attribute consumption to a specific server or tenant, spot a power supply that is drawing more than it should, and see exactly how much headroom each bank has before you add the next machine.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat can I do remotely with the switching?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTurn any outlet on or off, power-cycle a hung server or switch, set the order and delay in which outlets come up after a power failure, and lock an outlet so it cannot be switched by accident. All of it through the built-in web, SNMP, Telnet or SSH interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat supply does it need?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA 32 A IEC 60309 2P+E commando socket on a dedicated circuit. The 3 m cord is attached, so nothing to buy, but the socket is a fixed electrical installation. If you only have 16 A supplies, the AP8659 is the same unit at 16 A with a C20 inlet.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan I add temperature and humidity monitoring?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. The sensor port takes an APC temperature probe or the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH\u003c\/a\u003e temperature and humidity sensor, sold separately, and the readings appear alongside power in the web interface and in EcoStruxure IT.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider's specification guide for the AP8653 contains no surge section, joule rating or clamping figure. Surge and sag protection belongs at a UPS upstream.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does it compare with the APDU9953 in the 9000 series?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBoth are 0U, 32 A, 7.4 kW, 1,829 mm strips with twenty-one C13 and three C19 outlets on a captive IEC 60309 cord. The AP8653 is the 2G generation and meters every outlet individually; the APDU9953 is the newer 9000-series switched unit with Gigabit Ethernet and the NMC3 platform, but it is not metered per outlet. Choose on whether per-outlet energy data matters to you.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow long is the strip and will it fit my rack?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1,829 mm - a full-height unit sized for a 42U enclosure with a rear vertical channel - and 8.23 kg. Measure before ordering. In a short cabinet the 2U \u003ca href=\"\/products\/apc-rack-pdu-metered-2u-32a-230v-12-c13-4-c19\"\u003eAP7822B\u003c\/a\u003e offers 32 A horizontally, without the per-outlet features.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Metered-by-Outlet with Switching Rack PDU AP8653 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs the AP8653 with a 2-year manufacturer warranty.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482588020900,"sku":"AP8653","price":2902.6,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_979320a7-2309-4e28-885a-15db4c4336ef.jpg?v=1789712019","url":"https:\/\/sourceit.com.sg\/products\/apc-netshelter-metered-by-outlet-switched-rack-pdu-2g-0u-32a-230v-21-c13-3-c19-ap8653","provider":"SourceIT ","version":"1.0","type":"link"}