{"product_id":"apc-netshelter-metered-by-outlet-switched-rack-pdu-2g-0u-16a-230v-21-c13-3-c19-ap8659","title":"APC NetShelter Metered-by-Outlet Switched Rack PDU 0U 16A 230V C20 Inlet","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Metered-by-Outlet with Switching Rack PDU, 2G, 0U, 16A, 230V, 21 C13 \u0026amp; 3 C19 Outlets, IEC C20 Inlet (AP8659) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eEvery Outlet Metered, Every Outlet Switchable - at 16 A\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Metered-by-Outlet with Switching Rack PDU AP8659 brings per-outlet metering and per-outlet switching to a rack that only has a 16 A supply. Each of its twenty-four outlets - twenty-one IEC C13 and three IEC C19 - reports its own current, power and energy to ±3%, and each can be switched on, off or power-cycled over the network. It is the 16 A sibling of the 32 A AP8653.\u003c\/p\u003e\n\u003cp\u003eThat combination is what a Singapore colocation tenant or managed-service provider needs when the bill is per kilowatt-hour and the on-call engineer would rather reboot a frozen firewall from home than drive to the cage at 2 a.m.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e16 A Through an IEC C20 Inlet\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSchneider rates the AP8659 at 16 A on 230 V, with a nominal input of 200 to 230 V and an accepted range of 100 to 240 VAC. The inlet is an IEC 60320 C20, so it takes a standard C19-to-C20 cord from a rack UPS outlet or a row PDU - no commando socket required. Schneider's published load figure for this part number is 3,300 VA, which is the North American 208 V rating; the 16 A limit is what governs the strip on a 230 V supply.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBuilt-In Management, LCD and a Sensor Port\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWeb, HTTPS, SNMP, Telnet and SSH access are standard, reporting into EcoStruxure IT, and Schneider includes a one-year Secure Network Management Card subscription. A local display shows the load at the strip, a port takes an APC temperature or temperature and humidity sensor, and user-defined alarm thresholds warn you before a circuit is overloaded. Outlets accept APC locking input cords.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eA Full-Height 0U Strip at 6 kg\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AP8659 is 1,829 mm long, 56 mm wide and 51 mm deep, weighing 6.09 kg - a full-height unit for a 42U enclosure with a rear vertical channel, mounted toolless and consuming no rack units. It is rated to operate from -5 to 60 °C, which gives useful margin in a hot-aisle or a cabinet whose cooling is marginal.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP8659 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Metered-by-Outlet with Switching Rack PDU, 2G, 0U, 20A\/208V, 16A\/230V, 21 C13 and 3 C19 outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP8659\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMetered-by-Outlet with Switching Rack Power Distribution Unit (PDU), 2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eZero U (0U), vertical side mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C20 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Cord\u003c\/td\u003e\n\u003ctd\u003eNot listed in Schneider's package contents - ask us to quote a C19-to-C20 cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e200 V, 208 V, 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceptable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e16 A at 230 V (20 A at 208 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Capacity (as published)\u003c\/td\u003e\n\u003ctd\u003e3,300 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eTwenty-one (21) IEC 60320 C13 and three (3) IEC 60320 C19 - 24 outlets total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V (also 100 V, 200 V, 208 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Locking\u003c\/td\u003e\n\u003ctd\u003eLocking IEC receptacles, compatible with APC locking input cords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMetering, Switching \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003ePer outlet - current, power and energy for each of the 24 outlets, plus device level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3% (amps, volts, kW, kWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd\u003eIndividual on\/off control of every outlet over the network, with power sequencing delays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Display\u003c\/td\u003e\n\u003ctd\u003eDigital display for local current monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eBuilt in as standard - no separate card required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interfaces\u003c\/td\u003e\n\u003ctd\u003eWeb, HTTPS, SNMP, Telnet, SSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Platform\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure IT and other platforms. A one-year Secure Network Management Card subscription is included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Ports\u003c\/td\u003e\n\u003ctd\u003eSerial configuration port, CAN port (terminator supplied), temperature\/humidity sensor port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Sensors\u003c\/td\u003e\n\u003ctd\u003eAPC temperature or temperature and humidity sensor, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided - no surge suppression is specified for this product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e1,829 x 56 x 51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e6.09 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e8.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eToolless vertical mounting; rack mounting brackets included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 15,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003ePSE, UL, VCCI Class A, VDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A, EN 55022 Class A, EN 55024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS \/ REACh\u003c\/td\u003e\n\u003ctd\u003eRoHS compliant; REACh compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Rack Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Twenty-one IEC C13 outlets for C14-corded servers, switches, firewalls and appliances, plus three IEC C19 outlets for C20-corded storage shelves and larger switches. The locking receptacles work with APC locking input cords so a lead cannot be pulled out during a rack tidy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoad planning.\u003c\/strong\u003e 16 A total at 230 V, shared by twenty-four outlets. Because every outlet is metered, you can see exactly where the amps are going and move a server to another strip before the limit is reached; the alarm thresholds give you the warning in advance. Plan against total nameplate current, not outlet count, and remember that 16 A is the strip - a rack of dual-PSU servers usually needs the 32 A AP8653 or two 16 A strips on A and B feeds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeeding it.\u003c\/strong\u003e An IEC C20 inlet. Schneider does not list an input cord in the package contents for this part, so ask us to quote the right C19-to-C20 cord when you order. The supply should be a 16 A outlet - a C19 on a rack UPS or on a row PDU. If the rack has a 16 A IEC 60309 socket instead, tell us and we will quote a locking C19-to-IEC 60309 lead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e A 0U strip 1,829 mm long, 56 mm wide and 51 mm deep, weighing 6.09 kg. It needs a full-height enclosure with a rear vertical channel and mounts toolless, consuming no rack units. In a short cabinet the 1U switched \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e gives eight switched C13 outlets at 16 A, though with aggregate rather than per-outlet metering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManagement and sensors.\u003c\/strong\u003e Web, HTTPS, SNMP, Telnet and SSH built in, reporting into EcoStruxure IT, with a one-year Secure NMC subscription included. The sensor port takes an APC temperature probe or the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH\u003c\/a\u003e temperature and humidity sensor - the one most Singapore sites want, given how quickly rack inlet temperature and humidity both matter here.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it does not do.\u003c\/strong\u003e No surge protection and no battery - a switched PDU controls power, it does not condition or store it, so a UPS is still required upstream. The AP9640 and AP9641 cards we sell are Smart-UPS accessories and have nothing to do with this PDU.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Metered and Switched Rack PDU Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC NetShelter Metered-by-Outlet with Switching Rack PDU (AP8659)\u003c\/li\u003e\n\u003cli\u003eRack mounting brackets\u003c\/li\u003e\n\u003cli\u003eCAN port terminator\u003c\/li\u003e\n\u003cli\u003eSerial configuration cable\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003cli\u003eSafety guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider does not list an input cord in the package contents for the AP8659, so ask us to quote a C19-to-C20 lead - or a locking C19-to-IEC 60309 lead if your rack has a commando socket - when you order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMetered \u0026amp; Switched Rack PDU Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 10 A, 2.3 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C14 inlet, 2.4 m cord\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, 2.4 m cord\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, no cord\u003c\/td\u003e\n\u003ctd\u003e(18) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 902 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8858EU3\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 16 A locking cord, 3 m\u003c\/td\u003e\n\u003ctd\u003e(18) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 902 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP8659 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMetered-by-Outlet + Switched\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 16 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC C20 inlet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(21) C13, (3) C19\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0U, 1,829 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8653\u003c\/td\u003e\n\u003ctd\u003eMetered-by-Outlet + Switched\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord, 3 m\u003c\/td\u003e\n\u003ctd\u003e(21) C13, (3) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,829 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPDU9959EU3\u003c\/td\u003e\n\u003ctd\u003eSwitched (9000 series)\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, 3 m locking IEC 60309 16 A cord\u003c\/td\u003e\n\u003ctd\u003e(21) C13, (3) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,794 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(36) C13, (6) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,791 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Sensor (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335TH\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAPC Temperature \u0026amp; Humidity Sensor\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eAPC also makes a temperature-only probe, the AP9335T. We do not hold it as a stock line - ask us and we will quote it.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP8659. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/AP8659\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric AP8659 product page (Singapore)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-4869_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Metered-by-Outlet with Switching Rack PDU AP8659 - Overview and Specifications (990-4869_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's own datasheet download links redirect to a host that has served wrong-model files, so email sales@sourceit.com.sg quoting the SKU for the PDF and we will send you the correct document.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP8659\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy does Schneider print 20 A \/ 208 V and 16 A \/ 230 V on the same part?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBecause the AP8659 is sold worldwide. On a North American 208 V supply it is rated 20 A; on a 230 V supply such as Singapore's it is rated 16 A. The 3,300 VA load figure in Schneider's data sheet is the 208 V rating. In Singapore, plan around 16 A at 230 V.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with a power cord?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSchneider's package contents for the AP8659 list the PDU, brackets, CAN terminator, serial cable and documentation, but no input cord. The inlet is an IEC C20, so you need a C19-to-C20 lead from your UPS or row PDU - ask us and we will add the right one to the quote.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat does metered-by-outlet give me over the AP8858's bank metering?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA separate current, power and energy reading for every one of the twenty-four outlets, to ±3%, rather than one figure for the whole strip. That is what you need to bill a tenant, find a power supply that is drawing more than it should, or know exactly which server to move when a strip is near its limit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat can I do remotely with the switching?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTurn any outlet on or off, power-cycle a hung device, set the power-on sequence and delays after an outage, and lock outlets against accidental switching - all from the built-in web, SNMP, Telnet or SSH interface, or through EcoStruxure IT.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan I add temperature and humidity monitoring?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. The sensor port takes an APC temperature probe or the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH\u003c\/a\u003e temperature and humidity sensor, sold separately.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the difference between the AP8659 and the AP8653?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInput capacity only. Both are 1,829 mm strips with twenty-one C13 and three C19 outlets, each metered and switched. The AP8659 is 16 A through a C20 inlet; the AP8653 is 32 A through a captive IEC 60309 commando cord, giving 7.4 kW. If the rack has a 32 A socket and a heavy server load, take the AP8653.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider's specification guide for the AP8659 has no surge section, joule rating or clamping figure. Put a UPS upstream if you need surge and sag protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs a network card needed?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo - network management is built in. Web, SNMP, Telnet and SSH are standard and there is nothing to fit. The AP9640 and AP9641 cards are for Smart-UPS units, not for this PDU.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Metered-by-Outlet with Switching Rack PDU AP8659 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs the AP8659 with a 2-year manufacturer warranty.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482588151972,"sku":"AP8659","price":2300.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_9c9eb646-916a-4d62-b3df-b159831fa20d.jpg?v=1789712114","url":"https:\/\/sourceit.com.sg\/products\/apc-netshelter-metered-by-outlet-switched-rack-pdu-2g-0u-16a-230v-21-c13-3-c19-ap8659","provider":"SourceIT ","version":"1.0","type":"link"}