{"product_id":"apc-netshelter-jumper-power-cord-c19-to-c20-16a-2-0m-ap9877","title":"APC NetShelter Jumper Power Cord IEC C19 to C20 16A 2.0m Black","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Jumper Power Cord, IEC C19 to C20, 16A, 2.0 m (AP9877) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eThe C19 to C20 Jumper for High-Power Rack Connections\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Power Cord AP9877 is a 2.0 m IEC 60320 C19 to C20 jumper: a C20 plug for a C19 outlet on a UPS, Rack ATS or PDU, and a C19 connector for the C20 inlet on the device being fed. It is the cord for anything in the rack that runs above the 10 A limit of a C13 - a 16 A PDU hanging off a UPS, a Rack ATS with C20 inlets, a blade chassis, a large storage shelf or a core switch.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRated for the Full C19\/C20 Coupler Capacity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIEC 60320 rates the C19\/C20 coupler at 16 A, and that is the figure that applies on a 230 V Singapore installation. Schneider's US listing prints the same coupler's 20 A North American rating. Either way the cord is built for the whole coupler capacity, which is what a 16 A PDU or ATS needs - a C13 cord cannot physically mate with a C20 inlet, and would be under-rated if it could.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e2.0 m for UPS-to-PDU and ATS Runs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTwo metres covers the typical connection from a UPS's C19 outlet at the bottom of the rack to a zero-U PDU inlet on the rear rail, or from a UPS to a Rack ATS in the next few U. It also reaches from a 1U ATS or PDU to a heavy device further up the same cabinet, with enough slack to route through the cable management.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSupplied Locally in Singapore with GST Invoice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSchneider lists the AP9877 as EU RoHS compliant and REACh conformant, with a 2-year repair-or-replace warranty. SourceIT supplies it with a GST invoice and local Singapore warranty support and will add the right number to any UPS, ATS or PDU quotation.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP9877 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP9877\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Power Cord, IEC C19 to C20, 2.0m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Power Cords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower cord (jumper)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity per Pack\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric) - repair or replace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eYes - supplied and supported locally by SourceIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eConnectors \u0026amp; Electrical\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug End\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C20 (3-pin male)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector End\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C19 (3-pin female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 60320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e16 A under IEC 60320 (the C19\/C20 coupler rating used in Singapore); Schneider's US attribute sheet prints the coupler's 20 A North American rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e2.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Gauge\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this part\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards (as printed)\u003c\/td\u003e\n\u003ctd\u003eEU RoHS compliant; REACh - free of substances of very high concern above threshold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it goes.\u003c\/strong\u003e C20 plug into a C19 outlet; C19 connector into a C20 inlet. Both ends are IEC 60320, so it never touches a wall socket - it lives entirely inside the rack, between APC equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eC19 outlets that feed it, from the SourceIT catalogue.\u003c\/strong\u003e UPS: \u003ca href=\"\/products\/apc-smart-ups-on-line-3kva-rackmount-2u-230v-8x-c13-2x-c19-iec-srt3000rmxli\"\u003eSmart-UPS SRT 3000VA (8 C13, 2 C19 outlets)\u003c\/a\u003e and \u003ca href=\"\/products\/apc-smart-ups-3000va-lcd-rm-2u-230v-smt3000rmi2u\"\u003eSmart-UPS SMT 3000VA rackmount\u003c\/a\u003e (two C19 outlets each). Rack ATS: \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423A Rack ATS (C20 in, 8 C13 and 1 C19 out)\u003c\/a\u003e (one C19 outlet) and \u003ca href=\"\/products\/apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424\"\u003eAP4424A Rack ATS (IEC 309 32 A in, 16 C13 and 2 C19 out)\u003c\/a\u003e (two). PDUs: \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552 zero-U basic PDU (20 C13, 4 C19, C20 inlet)\u003c\/a\u003e, \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853 metered zero-U PDU (36 C13, 6 C19)\u003c\/a\u003e, \u003ca href=\"\/products\/apc-rack-pdu-metered-2u-32a-230v-12-c13-4-c19\"\u003eAP7822B metered 2U PDU (12 C13, 4 C19)\u003c\/a\u003e and \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423A Rack ATS (C20 in, 8 C13 and 1 C19 out)\u003c\/a\u003e all carry C19 outlets. Bypass: \u003ca href=\"\/products\/apc-service-bypass-pdu-230v-16amp-w-6-iec-c13-and-1-c19\"\u003eSBP3000RMI service bypass PDU (6 C13, 1 C19)\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eC20 inlets it feeds.\u003c\/strong\u003e Rack PDUs \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552 zero-U basic PDU (20 C13, 4 C19, C20 inlet)\u003c\/a\u003e and \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B switched 1U PDU (8 C13, C20 cord)\u003c\/a\u003e, the \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423A Rack ATS (C20 in, 8 C13 and 1 C19 out)\u003c\/a\u003e Rack ATS (two C20 inlets, so two cords for two sources), and any server, blade chassis or storage shelf with a C20 inlet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe classic pairing.\u003c\/strong\u003e Smart-UPS SRT C19 outlet, AP9877, C20-inlet PDU. That puts a whole 16 A PDU behind the UPS with one cord and no adapters. Add a second SRT and an AP4423A ATS in between, with an AP9877 from each UPS into the ATS, and every single-corded device on the PDU gets two sources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRating.\u003c\/strong\u003e Plan on 16 A - the IEC 60320 coupler rating and the rating of every 16 A UPS outlet and PDU inlet it will meet in Singapore. The 20 A figure on Schneider's US listing is the same coupler under North American rules, not extra headroom on a 16 A circuit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIEC Connector Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRack power cords are named by the IEC 60320 coupler on each end. The socket side of a coupler is the odd number and the pin side is the even number, so a C14 plug goes into a C13 outlet and a C19 connector goes onto a C20 inlet.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFound on\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMates with\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC13 (socket)\u003c\/td\u003e\n\u003ctd\u003eCord end that goes into equipment; PDU, UPS and ATS outlets\u003c\/td\u003e\n\u003ctd\u003eC14\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC14 (pins)\u003c\/td\u003e\n\u003ctd\u003eCord plug; inlet on servers, switches, 10 A PDUs and UPS units\u003c\/td\u003e\n\u003ctd\u003eC13\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC19 (socket)\u003c\/td\u003e\n\u003ctd\u003eCord end for high-power equipment; outlets on larger UPS, ATS and PDUs\u003c\/td\u003e\n\u003ctd\u003eC20\u003c\/td\u003e\n\u003ctd\u003e16 A (IEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC20 (pins)\u003c\/td\u003e\n\u003ctd\u003eCord plug; inlet on 16 A PDUs, Rack ATS and high-power servers\u003c\/td\u003e\n\u003ctd\u003eC19\u003c\/td\u003e\n\u003ctd\u003e16 A (IEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEC 60309 16 A 2P+E (blue commando)\u003c\/td\u003e\n\u003ctd\u003eWall and busway sockets, UPS and bypass outlets, captive PDU and ATS input cords\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 16 A socket\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eNot one of these is a BS 1363 (Type G) wall plug. In a Singapore rack the mains connection is normally made once, at the UPS or PDU input, and everything downstream is IEC to IEC.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; APC NetShelter Power Cord Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC NetShelter Power Cord, IEC C19 to C20, 2.0 m (AP9877)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAPC NetShelter Power Cords — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese five NetShelter cords cover the common rack connections. Each is a separate listing; the one you are reading is in bold.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical use\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9870\u003c\/td\u003e\n\u003ctd\u003eIEC C13 to C14\u003c\/td\u003e\n\u003ctd\u003e10 A, 250 V\u003c\/td\u003e\n\u003ctd\u003e2.5 m\u003c\/td\u003e\n\u003ctd\u003eEquipment cord: PDU, UPS or ATS C13 outlet to a C14 inlet on a server or switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9876\u003c\/td\u003e\n\u003ctd\u003eIEC C19 to IEC 60309 16 A plug\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003ctd\u003e2.5 m\u003c\/td\u003e\n\u003ctd\u003eInput cord: 16 A commando socket to a C20-inlet PDU, ATS or UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP9877 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC C19 to C20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16 A (IEC 60320)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.0 m\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eJumper: UPS or ATS C19 outlet to a C20-inlet PDU, ATS or high-power server\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9878\u003c\/td\u003e\n\u003ctd\u003eIEC C19 to C14\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003ctd\u003e2.0 m\u003c\/td\u003e\n\u003ctd\u003eAdapter cord: C13 outlet to a C20-inlet device at 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9890\u003c\/td\u003e\n\u003ctd\u003eIEC C13 to C14, 5 cords\u003c\/td\u003e\n\u003ctd\u003e10 A (IEC 60320 coupler rating)\u003c\/td\u003e\n\u003ctd\u003e0.6 m\u003c\/td\u003e\n\u003ctd\u003eShort equipment cords for tidy in-rack runs from a zero-U PDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Alternative\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAP8704S-WW locking C13 to C14 cord kit, 6 x 1.2 m\u003c\/a\u003e - locking C13 connectors that cannot be nudged out of a PDU outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP9877. Links open in a new tab.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric product page\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/product\/AP9877\/apc-netshelter-power-cord-iec-c19-to-c20-2-0m\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC AP9877 NetShelter Power Cord, IEC C19 to C20, 2.0 m on se.com\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eSchneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eAP9877\u003c\/strong\u003e and we will send you the current PDF datasheet and user guide directly.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP9877\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat is a C19 to C20 jumper for?\u003c\/h3\u003e\n\u003cp\u003eConnecting two pieces of rack equipment that both use the 16 A IEC connector: a UPS with C19 outlets to a PDU with a C20 inlet, a UPS to a Rack ATS with C20 inlets, or a PDU or ATS C19 outlet to a server, blade chassis or storage shelf with a C20 inlet. It is the 16 A equivalent of the everyday C13 to C14 cord.\u003c\/p\u003e\n\u003ch3\u003eIs it 16 A or 20 A?\u003c\/h3\u003e\n\u003cp\u003eBoth figures refer to the same IEC 60320 C19\/C20 coupler: 16 A under the IEC standard used in Singapore and Europe, 20 A under the North American rating that appears on Schneider's US attribute sheet. On a 230 V Singapore installation, plan on 16 A - that is what the UPS outlet, the PDU inlet and the branch circuit behind them are rated for.\u003c\/p\u003e\n\u003ch3\u003eWhich APC UPS models have C19 outlets?\u003c\/h3\u003e\n\u003cp\u003eIn the SourceIT catalogue the \u003ca href=\"\/products\/apc-smart-ups-on-line-3kva-rackmount-2u-230v-8x-c13-2x-c19-iec-srt3000rmxli\"\u003eSmart-UPS SRT 3000VA (8 C13, 2 C19 outlets)\u003c\/a\u003e and \u003ca href=\"\/products\/apc-smart-ups-3000va-lcd-rm-2u-230v-smt3000rmi2u\"\u003eSmart-UPS SMT 3000VA rackmount\u003c\/a\u003e each provide two C19 outlets alongside their C13s, and the \u003ca href=\"\/products\/apc-service-bypass-pdu-230v-16amp-w-6-iec-c13-and-1-c19\"\u003eSBP3000RMI service bypass PDU (6 C13, 1 C19)\u003c\/a\u003e bypass PDU has one. The Easy UPS On-Line SRV 1 to 3 kVA units use C13 outlets only, so they do not take this cord.\u003c\/p\u003e\n\u003ch3\u003eCan I use it to feed the AP4423A Rack ATS?\u003c\/h3\u003e\n\u003cp\u003eYes - that is one of its main jobs. The \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423A Rack ATS (C20 in, 8 C13 and 1 C19 out)\u003c\/a\u003e has two C20 inlets. Run an AP9877 from a C19 outlet on each of two independent sources - two UPS units, or a UPS and a bypass PDU - into the two inlets. If a source is a commando socket rather than a C19 outlet, use the AP9876 for that side instead.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between this and the AP9878?\u003c\/h3\u003e\n\u003cp\u003eThe plug end and the rating. The AP9877 has a C20 plug and carries the full 16 A coupler rating. The AP9878 has a C14 plug, so it draws from a C13 outlet and is limited to 10 A - a way to power a C20-inlet device from a C13 outlet when the load is small. Same C19 connector on the equipment end.\u003c\/p\u003e\n\u003ch3\u003eIs 2.0 m long enough?\u003c\/h3\u003e\n\u003cp\u003eFor a UPS-to-PDU or UPS-to-ATS run in the same rack, yes, with slack for routing. For a run between racks, measure the route through the cable tray first and tell us the distance.\u003c\/p\u003e\n\u003ch3\u003eWill this plug into a Singapore wall socket?\u003c\/h3\u003e\n\u003cp\u003eNo. The AP9877 has an IEC C20 plug and an IEC C19 connector. Singapore wall sockets are BS 1363 (Type G), and none of the connectors on this cord are BS 1363. The normal Singapore arrangement is an IEC-fed rack PDU or a UPS with IEC outlets, with cords like this one running from those outlets to the equipment. If you need a BS 1363 to IEC lead for a UPS or PDU input, ask us separately.\u003c\/p\u003e\n\u003ch3\u003eDoes it come with a Singapore warranty?\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC AP9877 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs its NetShelter power cords with a 2-year repair-or-replace manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482608304292,"sku":"AP9877","price":44.16,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_c6a0b904-c801-444c-9555-b23f92bc656a.jpg?v=1789715667","url":"https:\/\/sourceit.com.sg\/products\/apc-netshelter-jumper-power-cord-c19-to-c20-16a-2-0m-ap9877","provider":"SourceIT ","version":"1.0","type":"link"}