{"product_id":"apc-netshelter-9000-switched-rack-pdu-0u-32a-230v-21-c13-3-c19-iec-309-apdu9953","title":"APC NetShelter 9000 Switched Rack PDU 0U 32A 230V 21 C13 3 C19 IEC 309","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Switched Rack PDU, 9000 Series, 0U, 32A, 230V, 21 C13 \u0026amp; 3 C19 Outlets, IEC 309 Cord (APDU9953) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eThe Current-Generation Switched Rack PDU at 32 A\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Switched Rack PDU APDU9953 is the 9000-series, 32 A, single-phase switched strip: twenty-one IEC C13 and three IEC C19 outlets, each of which can be switched on, off or power-cycled over the network, on a 0U vertical chassis fed by a captive 3 m IEC 60309 32 A cord. Schneider rates it at 7,400 VA, which is enough to run a full rack of dual-PSU servers from one strip.\u003c\/p\u003e\n\u003cp\u003eIt replaces the 2G-era switched units in the catalogue with a faster management platform and a chassis designed for warmer, denser racks - the two things that matter most in a Singapore data hall where the hot aisle is genuinely hot.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRemote Switching, Sequencing and Load Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEvery outlet is individually controllable, so a hung firewall or a wedged hypervisor becomes a browser action rather than a site visit. Outlet power-on sequencing and delays stop a rack from drawing its full inrush at once after an outage, and alarm thresholds on the metered load warn you before a bank is overloaded. Schneider includes a one-year Secure Network Management Card subscription, and the strip reports into EcoStruxure IT.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e9000-Series Platform: Gigabit Ethernet, NMC3, LCD, Sensor Port\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 9000 series is Schneider's current NetShelter switched platform: a Gigabit Ethernet management port on the NMC3 architecture, a local LCD with buttons for current, power and voltage, a USB port, a universal I\/O port for environmental sensors, and Network Port Sharing that lets one network connection manage a group of 9000-series strips through their Link A and Link B ports. Outlets are hybrid C13\/C15 and C19\/C21 types with a locking feature for APC locking cords, and each has a green LED that shows when it is energised.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eA Full-Height Strip, Rated 32 A, Weighing 7.3 kg\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APDU9953 is 1,829 mm long, 56 mm wide and 46 mm deep, weighing 7.34 kg. It is built for a full-height 42U enclosure with a rear vertical channel, mounts toolless with the supplied brackets and consumes no rack units. The captive commando cord means the rack needs a 32 A IEC 60309 socket on a dedicated circuit - a fixed electrical installation.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC APDU9953 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Switched Rack PDU, 9K series, 0U, 32A, 230V, 21 C13 and 3 C19 outlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAPDU9953\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSwitched Rack Power Distribution Unit (PDU), NetShelter 9000 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eZero U (0U), vertical side mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 32 A attached cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e200 V, 208 V, 230 V (220-240 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacity\u003c\/td\u003e\n\u003ctd\u003e7,400 VA (7,360 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eTwenty-one (21) IEC 60320 C13 and three (3) IEC 60320 C19 - 24 outlets total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Type\u003c\/td\u003e\n\u003ctd\u003eHybrid C13\/C15 and C19\/C21 outlets with locking feature for APC locking cords; per-outlet status LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercurrent Protection\u003c\/td\u003e\n\u003ctd\u003eCircuit breakers on the outlet banks - bank rating not published by Schneider Electric for this SKU, ask us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMetering, Switching \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd\u003eIndividual on\/off control of every outlet over the network, with power-on sequencing and delays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eCurrent, power and voltage for the PDU, shown on the LCD and over the network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Display\u003c\/td\u003e\n\u003ctd\u003eLCD with input buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eBuilt in - NMC3 platform, Gigabit Ethernet (10\/100\/1000BASE-T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interfaces\u003c\/td\u003e\n\u003ctd\u003eWeb, SNMP, SSH, EcoStruxure IT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Platform\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure IT. A one-year Secure Network Management Card subscription is included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Port Sharing\u003c\/td\u003e\n\u003ctd\u003eLink A and Link B ports - manage a group of 9000-series Rack PDUs through one network connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Ports\u003c\/td\u003e\n\u003ctd\u003eUSB port; universal I\/O port for environmental sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided - no surge suppression is specified for this product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e1,829 x 56 x 46 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e7.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e9.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eToolless vertical mounting; rack mounting brackets included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 3,048 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eEAC, RCM, VDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Rack Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Twenty-one IEC C13 outlets for C14-corded servers, switches and appliances, and three IEC C19 outlets for C20-corded storage shelves, blade chassis and core switches. The hybrid outlets also accept C15 and C21 plugs, and the locking feature works with APC locking cords.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoad planning.\u003c\/strong\u003e 32 A input and 7,400 VA total. The PDU meters its load and shows it on the LCD and over the network, and you can set alarm thresholds so it warns you before a bank is overloaded. Twenty-four outlets on 7.4 kW is modest per-outlet draw; the outlets are there for reach, not so each can pull its maximum. For per-outlet energy data, the 2G AP8653 is the alternative at the same rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeeding it.\u003c\/strong\u003e A captive 3 m IEC 60309 32 A commando cord. The rack needs a matching 32 A socket on a dedicated circuit. If the site only has 16 A supplies, the APDU9959EU3 is the same 9000-series strip at 16 A with a C20 inlet and a locking IEC 60309 16 A cord.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e A 0U strip 1,829 mm long, 56 mm wide and 46 mm deep, weighing 7.34 kg - a full-height unit for a 42U enclosure with a rear vertical channel. It mounts toolless and consumes no rack units. In a short cabinet the 1U switched \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e (16 A, eight C13) is the compact alternative.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManagement and sensors.\u003c\/strong\u003e Gigabit Ethernet on the NMC3 platform with Web, SNMP and SSH, reporting into EcoStruxure IT, plus Network Port Sharing so a row of 9000-series strips can share one uplink. The universal I\/O port takes an APC environmental sensor; ask us to confirm the right sensor part for the 9000 series when you order. The AP9640 and AP9641 cards we sell are Smart-UPS accessories and are not used with this PDU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it does not do.\u003c\/strong\u003e No surge protection and no battery - a switched PDU controls power, it does not condition or store it, so a UPS upstream is still required. It is not metered per outlet; that is the AP8653.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; NetShelter 9000 and Switched Rack PDU Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC NetShelter Switched Rack PDU 9000 series (APDU9953) with attached 3 m IEC 60309 32 A input cord\u003c\/li\u003e\n\u003cli\u003eRack mounting brackets\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003cli\u003eSafety guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eNetShelter 9000 \u0026amp; Switched Rack PDU Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 10 A, 2.3 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C14 inlet, 2.4 m cord\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, 2.4 m cord\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPDU9959EU3\u003c\/td\u003e\n\u003ctd\u003eSwitched (9000 series)\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, 3 m locking IEC 60309 16 A cord\u003c\/td\u003e\n\u003ctd\u003e(21) C13, (3) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,794 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPDU9953 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitched (9000 series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 32 A, 7.4 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCaptive IEC 60309 32 A cord, 3 m\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(21) C13, (3) C19\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0U, 1,829 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8659\u003c\/td\u003e\n\u003ctd\u003eMetered-by-Outlet + Switched (2G)\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet\u003c\/td\u003e\n\u003ctd\u003e(21) C13, (3) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,829 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8653\u003c\/td\u003e\n\u003ctd\u003eMetered-by-Outlet + Switched (2G)\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord, 3 m\u003c\/td\u003e\n\u003ctd\u003e(21) C13, (3) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,829 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(36) C13, (6) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,791 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-rack-pdu-switched-0u-3-phase-22kw-230v-epdu1232s\"\u003eEPDU1232S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched (Easy Rack PDU)\u003c\/td\u003e\n\u003ctd\u003e230 V, 3-phase, 22 kW\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 3P+N+E\u003c\/td\u003e\n\u003ctd\u003eSee listing\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-rack-pdu-advanced-metered-3phase-apdu10450me\"\u003eAPDU10450ME\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAdvanced Metered\u003c\/td\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003ctd\u003eSee listing\u003c\/td\u003e\n\u003ctd\u003eSee listing\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC APDU9953. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/APDU9953\/apc-rack-pdu-9000-switched-zerou-32a-230v-21-c13-3-c19\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric APDU9953 product page (Singapore)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-91389_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eNetShelter 9000 Series Switched Rack PDU APDU9953 - Overview and Specifications (990-91389_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/ca\/en\/download\/document\/990-6302-001_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eNetShelter 9000 Series Switched Rack PDU - User Guide (990-6302-001_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's own datasheet download links redirect to a host that has served wrong-model files, so email sales@sourceit.com.sg quoting the SKU for the PDF and we will send you the correct document.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC APDU9953\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is different about the 9000 series compared with the older switched PDUs?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe management platform and the chassis. The 9000 series runs on the NMC3 architecture with a Gigabit Ethernet port, has an LCD with buttons, a USB port, a universal sensor port and Network Port Sharing across a group of strips, and its outlets are hybrid C13\/C15 and C19\/C21 with a locking feature and a status LED each. The switching, sequencing and alarm functions are the same idea as before, done on newer hardware.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs it metered per outlet?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. The APDU9953 meters the PDU load - current, power and voltage - and switches every outlet individually, but it does not report energy per outlet. If per-outlet metering is the requirement, the 2G AP8653 provides it at the same 32 A rating and outlet count.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat supply does it need?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA 32 A IEC 60309 commando socket on a dedicated circuit. The 3 m cord is attached, so there is nothing to buy, but the socket is a fixed electrical installation - budget for an electrician if one is not already in the rack.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is Network Port Sharing?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA way of managing several 9000-series Rack PDUs through one network connection. The strips are cabled together through their Link A and Link B ports and appear under the one management interface, which saves switch ports and IP addresses in a row of racks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan I add a temperature and humidity sensor?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes - the 9000 series has a universal I\/O port for APC environmental sensors. Ask us to confirm the right sensor part number for the 9000 series when you order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider's specification sheet for the APDU9953 has no surge section, joule rating or clamping figure. Surge and sag protection belongs at a UPS upstream.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDo I need a network management card?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Network management is built into the strip on the NMC3 platform, with a one-year Secure Network Management Card subscription included. The AP9640 and AP9641 cards are Smart-UPS accessories and are not used with this PDU.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does it compare with the APDU9959EU3?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSame 9000-series platform and the same twenty-one C13 and three C19 outlets. The APDU9953 is 32 A and 7.4 kW on a captive IEC 60309 32 A cord and is 1,829 mm long; the APDU9959EU3 is 16 A and 3.7 kW with a C20 inlet and a supplied locking IEC 60309 16 A cord, and is 1,794 mm long. Choose on the supply you have in the rack.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Switched Rack PDU 9000 APDU9953 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs the APDU9953 with a 2-year manufacturer warranty.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482588414116,"sku":"APDU9953","price":1623.8,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_8a90682b-b80a-4d59-8584-913873bbcde5.jpg?v=1789712377","url":"https:\/\/sourceit.com.sg\/products\/apc-netshelter-9000-switched-rack-pdu-0u-32a-230v-21-c13-3-c19-iec-309-apdu9953","provider":"SourceIT ","version":"1.0","type":"link"}