{"product_id":"apc-netshelter-9000-switched-rack-pdu-0u-16a-230v-21-c13-3-c19-iec-309-cord-apdu9959eu3","title":"APC NetShelter 9000 Switched Rack PDU 0U 16A 230V 24 Outlets IEC 309 Cord","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Switched Rack PDU, 9000 Series, 0U, 16A, 230V, 21 C13 \u0026amp; 3 C19 Outlets, IEC 309 Cord (APDU9959EU3) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTwenty-Four Switched Outlets on a 16 A Commando Feed\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Switched Rack PDU APDU9959EU3 is the 16 A member of the 9000 series for 230 V racks: twenty-one IEC C13 and three IEC C19 outlets, each individually switchable over the network, rated 3,700 VA. The \"EU3\" suffix means it ships with a 3 m locking input cord that ends in an IEC 60309 16 A 2P+E plug - the blue commando connector found on row PDUs and busway tap-offs in Singapore data centres - plugged into the strip's C20 inlet.\u003c\/p\u003e\n\u003cp\u003eIt is the strip to specify when a rack has a 16 A feed and you want remote power-cycling on every outlet without paying for 32 A capacity you cannot use.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRemote Switching, Sequencing and Alarms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAny outlet can be switched on, off or power-cycled from the built-in web, SNMP or SSH interface or through EcoStruxure IT, so a hung switch in a colocation cage is fixed from your desk. Power-on sequencing and delays keep a rack from drawing its full inrush at once after an outage, and alarm thresholds on the metered load warn you before the 16 A limit is reached. A one-year Secure Network Management Card subscription is included.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e9000-Series Platform: Gigabit Ethernet, NMC3, LCD, Sensor Port\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 9000 series is Schneider's current NetShelter switched platform: a Gigabit Ethernet management port on the NMC3 architecture, a local LCD with buttons for current, power and voltage, a USB port, a universal I\/O port for environmental sensors, and Network Port Sharing that lets one network connection manage a group of 9000-series strips through their Link A and Link B ports. Outlets are hybrid C13\/C15 and C19\/C21 types with a locking feature for APC locking cords, and each has a green LED that shows when it is energised.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e1,794 mm Long and 5.6 kg\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APDU9959EU3 is 1,794 mm long, 55 mm wide and 46 mm deep, weighing 5.61 kg - a full-height 0U unit for a 42U enclosure with a rear vertical channel, mounted toolless with the supplied brackets and consuming no rack units.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC APDU9959EU3 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Switched Rack PDU, 9K series, 0U, 16A, 230V, 21 C13 and 3 C19 outlets, IEC309 Cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAPDU9959EU3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSwitched Rack Power Distribution Unit (PDU), NetShelter 9000 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eZero U (0U), vertical side mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C20 inlet, with supplied locking cord to IEC 60309 16 A 2P+E plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceptable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e220-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacity\u003c\/td\u003e\n\u003ctd\u003e3,700 VA (3.7 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eTwenty-one (21) IEC 60320 C13 and three (3) IEC 60320 C19 - 24 outlets total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Total Current Draw\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Type\u003c\/td\u003e\n\u003ctd\u003eHybrid C13\/C15 and C19\/C21 outlets with locking feature for APC locking cords; per-outlet status LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMetering, Switching \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd\u003eIndividual on\/off control of every outlet over the network, with power-on sequencing and delays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eCurrent, power and voltage for the PDU, shown on the LCD and over the network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Display\u003c\/td\u003e\n\u003ctd\u003eLCD with input buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eBuilt in - NMC3 platform, Gigabit Ethernet (10\/100\/1000BASE-T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interfaces\u003c\/td\u003e\n\u003ctd\u003eWeb, SNMP, SSH, EcoStruxure IT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Platform\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure IT. A one-year Secure Network Management Card subscription is included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Port Sharing\u003c\/td\u003e\n\u003ctd\u003eLink A and Link B ports - manage a group of 9000-series Rack PDUs through one network connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Ports\u003c\/td\u003e\n\u003ctd\u003eUSB port; universal I\/O port for environmental sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided - no surge suppression is specified for this product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e1,794 x 55 x 46 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e5.61 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e8.59 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eToolless vertical mounting; rack mounting brackets included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 3,048 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eEAC, RCM, VDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A, ICES-003, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS \/ REACh\u003c\/td\u003e\n\u003ctd\u003eRoHS compliant with exemptions; REACh declaration available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Rack Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Twenty-one IEC C13 outlets for C14-corded servers, switches and appliances, and three IEC C19 outlets for C20-corded storage or larger switches. The hybrid outlets also accept C15 and C21 plugs, and the locking feature works with APC locking cords.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoad planning.\u003c\/strong\u003e 16 A total, 3,700 VA at 230 V, shared by twenty-four outlets. The PDU meters its load and lets you set an alarm threshold, so you see the headroom rather than guess it. A rack of dual-PSU servers usually wants two 16 A strips on A and B feeds, or the 32 A APDU9953.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeeding it.\u003c\/strong\u003e The supplied 3 m locking cord plugs into the strip's C20 inlet and ends in an IEC 60309 16 A 2P+E commando plug, so the rack needs a 16 A commando socket on a row PDU, busway or fixed outlet. If the rack has a C19 outlet on a UPS instead, tell us - the same strip can be fed with a C19-to-C20 lead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e A 0U strip 1,794 mm long, 55 mm wide and 46 mm deep, weighing 5.61 kg. It needs a full-height enclosure with a rear vertical channel and mounts toolless, consuming no rack units. For a short cabinet the 1U \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e gives eight switched C13 outlets at 16 A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManagement and sensors.\u003c\/strong\u003e Gigabit Ethernet on the NMC3 platform with Web, SNMP and SSH, reporting into EcoStruxure IT, plus Network Port Sharing so a row of 9000-series strips can share one uplink. The universal I\/O port takes an APC environmental sensor; ask us to confirm the right sensor part for the 9000 series when you order. The AP9640 and AP9641 cards we sell are Smart-UPS accessories and are not used with this PDU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it does not do.\u003c\/strong\u003e No surge protection and no battery - a UPS upstream is still required. It is not metered per outlet; the 2G AP8659 provides per-outlet metering and switching at the same 16 A rating.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; NetShelter 9000 and Switched Rack PDU Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC NetShelter Switched Rack PDU 9000 series (APDU9959EU3)\u003c\/li\u003e\n\u003cli\u003e3 m locking input power cord, IEC 60309 16 A 2P+E plug\u003c\/li\u003e\n\u003cli\u003eRack mounting brackets\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003cli\u003eSafety guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eNetShelter 9000 \u0026amp; Switched Rack PDU Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 10 A, 2.3 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C14 inlet, 2.4 m cord\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, 2.4 m cord\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPDU9959EU3 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitched (9000 series)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 16 A, 3.7 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC C20 inlet, 3 m locking IEC 60309 16 A cord\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(21) C13, (3) C19\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0U, 1,794 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPDU9953\u003c\/td\u003e\n\u003ctd\u003eSwitched (9000 series)\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord, 3 m\u003c\/td\u003e\n\u003ctd\u003e(21) C13, (3) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,829 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8659\u003c\/td\u003e\n\u003ctd\u003eMetered-by-Outlet + Switched (2G)\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet\u003c\/td\u003e\n\u003ctd\u003e(21) C13, (3) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,829 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8653\u003c\/td\u003e\n\u003ctd\u003eMetered-by-Outlet + Switched (2G)\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord, 3 m\u003c\/td\u003e\n\u003ctd\u003e(21) C13, (3) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,829 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8858EU3\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e3 m locking cord, IEC 60309 16 A plug\u003c\/td\u003e\n\u003ctd\u003e(18) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 902 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-rack-pdu-switched-0u-3-phase-22kw-230v-epdu1232s\"\u003eEPDU1232S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched (Easy Rack PDU)\u003c\/td\u003e\n\u003ctd\u003e230 V, 3-phase, 22 kW\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 3P+N+E\u003c\/td\u003e\n\u003ctd\u003eSee listing\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC APDU9959EU3. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/APDU9959EU3\/apc-rack-pdu-9000-switched-zerou-16a-230v-21-c13-3-c19-iec309-cord\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric APDU9959EU3 product page (Singapore)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-91395_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eNetShelter 9000 Series Switched Rack PDU APDU9959EU3 - Overview and Specifications (990-91395_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/ca\/en\/download\/document\/990-6302-001_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eNetShelter 9000 Series Switched Rack PDU - User Guide (990-6302-001_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's own datasheet download links redirect to a host that has served wrong-model files, so email sales@sourceit.com.sg quoting the SKU for the PDF and we will send you the correct document.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC APDU9959EU3\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat does the EU3 suffix mean?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThat the strip ships with a 3 m locking input cord ending in an IEC 60309 16 A 2P+E commando plug, fitted to the strip's C20 inlet. It is the version for racks fed from 16 A commando sockets, which is the usual arrangement in Singapore data centres and colocation cages.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the capacity - some listings say 11 kW?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e16 A and 3,700 VA at 230 V. That is what Schneider's specification sheet for the APDU9959EU3 prints, and it is what a 16 A single-phase feed can deliver. Any larger figure you may see against this part number belongs to a three-phase model in the same series.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs it metered per outlet?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. The APDU9959EU3 meters the PDU load and switches every outlet individually, but it does not report energy per outlet. If per-outlet metering is the requirement, the 2G AP8659 provides it at the same 16 A rating and outlet count.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is Network Port Sharing?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA way of managing several 9000-series Rack PDUs through one network connection. The strips are cabled together through their Link A and Link B ports and appear under the one management interface, saving switch ports and IP addresses across a row.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan I add a temperature and humidity sensor?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes - the 9000 series has a universal I\/O port for APC environmental sensors. Ask us to confirm the right sensor part number for the 9000 series when you order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider's specification sheet for the APDU9959EU3 has no surge section, joule rating or clamping figure. Surge and sag protection belongs at a UPS upstream.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does it compare with the APDU9953?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSame 9000-series platform and the same twenty-one C13 and three C19 outlets. The APDU9959EU3 is 16 A and 3.7 kW with a C20 inlet and a supplied locking IEC 60309 16 A cord, 1,794 mm long; the APDU9953 is 32 A and 7.4 kW on a captive IEC 60309 32 A cord, 1,829 mm long. Choose on the supply in the rack and the load you need to carry.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDo I need a network management card?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Management is built into the strip on the NMC3 platform with a one-year Secure Network Management Card subscription included. The AP9640 and AP9641 cards are Smart-UPS accessories and are not used with this PDU.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Switched Rack PDU 9000 APDU9959EU3 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs the APDU9959EU3 with a 2-year manufacturer warranty.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482588741796,"sku":"APDU9959EU3","price":1568.6,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_a7096380-2d60-4598-8ac4-9733c8dcc160.jpg?v=1789712470","url":"https:\/\/sourceit.com.sg\/products\/apc-netshelter-9000-switched-rack-pdu-0u-16a-230v-21-c13-3-c19-iec-309-cord-apdu9959eu3","provider":"SourceIT ","version":"1.0","type":"link"}