{"product_id":"apc-easy-ups-on-line-srv-15kva-15kw-rackmount-9u-230v-extended-runtime-rail-kit-srv15krilrk","title":"APC Easy UPS On-Line SRV 15kVA 15kW Rackmount 9U 230V Extended Runtime Kit","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Easy UPS On-Line SRV 15kVA\/15kW Rackmount 9U Extended-Runtime UPS 230V with Battery Packs and Rail Kit (SRV15KRILRK) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eDouble-Conversion On-Line Protection at 15 kW for Singapore's 230V\/50Hz Supply\u003c\/h3\u003e\n\u003cp\u003eThe APC Easy UPS On-Line SRV15KRILRK is a true double-conversion on-line UPS rated at 15000 VA \/ 15000 W. Incoming mains is rectified to DC and rebuilt by the inverter as a clean 230 V sine wave with 2% maximum distortion, so the load never sees the raw utility waveform and there is no transfer to wait for when the supply fails. Rated efficiency is 95% at full load, with an energy-saving ECO mode available.\u003c\/p\u003e\n\u003cp\u003eIn Singapore the practical risk is far more often a sag, a brownout or a switching transient during a thunderstorm than a full blackout. The SRV15KRILRK accepts 176–300 V AC at full load and 110–300 V AC at half load, so those events are absorbed on the mains side and the batteries are held in reserve for a real outage. Output frequency is synchronised to the mains at 50\/60 Hz ±3 Hz.\u003c\/p\u003e\n\u003ch3\u003eUnity Power Factor — Every kVA Is a Real Kilowatt\u003c\/h3\u003e\n\u003cp\u003eThis model is rated at unity power factor: 15 kVA gives a full 15 kW with no derating, which is worth checking against competing units that quote 0.8 or 0.9 power factor at the same kVA. Size on watts: add up the continuous draw of everything to be protected, allow for start-up surge and growth, and compare it with 15000 W — or send us the load list and we will do the sum with you.\u003c\/p\u003e\n\u003ch3\u003eHardwired Input and Output, with a Single-Phase or Three-Phase Feed\u003c\/h3\u003e\n\u003cp\u003eThis is a hardwired unit. Schneider's product name reads “Hard wire 3-wire (1P+N+E) outlet”: the output is a terminal block, there are \u003cstrong\u003eno IEC C13 or C19 sockets\u003c\/strong\u003e, and the protected equipment connects through a downstream rack PDU or distribution board. On the input side Schneider fits two terminal connections — a 3-wire (1P+N+E) single-phase input at 230 V and a 5-wire (3P+N+E) three-phase input at 415 V — so the UPS can be fed from a single-phase 230 V circuit or from a 400\/415 V three-phase supply while still delivering a single-phase 230 V output.\u003c\/p\u003e\n\u003cp\u003eA 15 kW load draws in the order of 65 A at 230 V single-phase, which is why the three-phase input option matters: it spreads the draw across three phases and makes the supply circuit far easier to provision. Either way a licensed electrical worker must terminate both ends, and the circuit, breaker and cabling have to be sized before delivery day.\u003c\/p\u003e\n\u003ch3\u003e9U Kit: 3U Power Module, Two 3U Battery Packs and the Rail Kit\u003c\/h3\u003e\n\u003cp\u003eThe SRV15KRILRK is Schneider's complete kit part number: the power module, two external SRV120RLBP2-9A battery packs, the battery cable, rack brackets, stabilisation feet, jumper bars, the USB and RS-232 cables and the user manual, and the product name ends “W\/ Rail Kit”. The delivered system occupies \u003cstrong\u003e9U\u003c\/strong\u003e — a 3U power module plus two 3U battery packs — and weighs 157 kg, of which 64 kg is each battery pack.\u003c\/p\u003e\n\u003cp\u003eThe power module carries no internal batteries; all stored energy lives in the external packs, which is what lets the runtime scale. Schneider states the UPS accepts \u003cstrong\u003eup to 10 SRV120RLBP2-9A packs\u003c\/strong\u003e, and the 2340 W charger recharges the supplied packs in six hours. \u003cstrong\u003eCheck the cabinet before ordering:\u003c\/strong\u003e the kit is 690 mm deep, so a standard 600 mm comms cabinet will not take it. Plan on an 800–1000 mm deep server rack with rear clearance for the hardwired conduit, and mount the packs low.\u003c\/p\u003e\n\u003ch3\u003eBypass, Emergency Power Off and Network Management\u003c\/h3\u003e\n\u003cp\u003eAn internal bypass operates automatically on overload or fault and can be commanded manually from the LCD console, so a service visit does not have to drop the load. A rear-panel Emergency Power Off connector takes a room EPO loop, the Intelligent Card Slot accepts an AP9544 Network Management Card 3 for SNMP monitoring and network shutdown, and USB and RS-232 ports are fitted as standard.\u003c\/p\u003e\n\u003ch3\u003eSupplied Locally, with GST Invoice and Singapore Warranty\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the SRV15KRILRK as an APC by Schneider Electric product with a full GST invoice and local Singapore warranty support. Schneider's printed manufacturer term for this model is two years, repair or replace. Email sales@sourceit.com.sg with your load list and the hold-up time you need and we will size the UPS, the supply and the battery pack count with you.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRV15KRILRK Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line, 15kVA\/15kW, Rackmount 9U, 230V, Hard wire 3-wire(1P+N+E) outlet, Intelligent Card Slot, LCD, Extended Runtime, W\/ Rail Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRV15KRILRK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eRackmount, 9U in total (3U power module plus two 3U battery packs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit Composition\u003c\/td\u003e\n\u003ctd\u003ePower module, 2 x SRV120RLBP2-9A external battery packs, rail kit and mounting hardware in one part number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty, repair or replace (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eIncluded with every unit supplied by SourceIT, together with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eOutput\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e15000 VA \/ 15000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Factor\u003c\/td\u003e\n\u003ctd\u003eUnity (1.0) — the watt rating equals the VA rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V, configurable to 220 V \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±3 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Distortion\u003c\/td\u003e\n\u003ctd\u003e2% maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Crest Factor\u003c\/td\u003e\n\u003ctd\u003e3:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e95% at full load; energy-saving ECO mode available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connection\u003c\/td\u003e\n\u003ctd\u003e1 x hard wire 3-wire (1P+N+E) terminal block — no IEC receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bypass\u003c\/td\u003e\n\u003ctd\u003eAutomatic and manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e600 joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInput\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC single-phase or 415 V AC three-phase (220 V \/ 230 V \/ 415 V selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connections\u003c\/td\u003e\n\u003ctd\u003e1 x hard wire 3-wire (1P+N+E) and 1 x hard wire 5-wire (3P+N+E) — hardwired, no inlet plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (full load)\u003c\/td\u003e\n\u003ctd\u003e176–300 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (half load)\u003c\/td\u003e\n\u003ctd\u003e110–300 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBatteries \u0026amp; Runtime\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Configuration\u003c\/td\u003e\n\u003ctd\u003eNo internal batteries in the power module — all stored energy is in the external SRV120RLBP2-9A packs (two supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed lead-acid (VRLA), maintenance-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Bus Voltage\u003c\/td\u003e\n\u003ctd\u003e±120 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charger Power\u003c\/td\u003e\n\u003ctd\u003e2340 W rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e6 hours (as printed by Schneider for the kit as supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Battery Packs\u003c\/td\u003e\n\u003ctd\u003eUp to 10 x SRV120RLBP2-9A per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Load\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric as a figure we can reproduce — runtime depends on the load and the number of packs fitted; ask us for a sizing calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCommunications \u0026amp; Management\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eUSB, RS-232 serial, Intelligent Card Slot, EPO connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Panel\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eOptional AP9544 Network Management Card 3 in the Intelligent Card Slot; Schneider lists the NMC3 Easy UPS single-phase firmware on this product's page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBundled Shutdown Software\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this model — use the network management card for monitoring and shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e9U in total — 3U power module plus two 3U battery packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D), kit\u003c\/td\u003e\n\u003ctd\u003e393 x 438 x 690 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D), each battery pack\u003c\/td\u003e\n\u003ctd\u003e133 x 438 x 686 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e157 kg for the kit as supplied; each battery pack 64 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e196 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack-mounted, horizontal; rail kit and rack mounting brackets supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack, RAL 7010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e0–40 °C, 0–95% relative humidity non-condensing, 0–3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Environment\u003c\/td\u003e\n\u003ctd\u003e−20 to 60 °C, 0–95% relative humidity non-condensing, 0–15000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e65 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e2503 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 62040-1:2019\/A11:2021; EN\/IEC 62040-2:2006\/AC:2006; EN\/IEC 62040-2:2018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eUPS power module, 2 x SRV120RLBP2-9A external battery packs, battery cable, rail kit, 3 x rack mounting brackets, 3 x stabilisation\/wall-mounting feet, 6 x jumper bars, USB cable, RS-232 configuration cable, user manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat Connects to This UPS\u003c\/h3\u003e\n\u003cp\u003eThere are no IEC sockets on this model. The hard-wire 3-wire (1P+N+E) output feeds a rack PDU, a sub-distribution board or a dedicated final circuit, and your equipment plugs into that. A 15 kW load draws roughly 65 A at 230 V, so installations of this size normally split the output across several rack PDUs (such as the 16 A \u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559\u003c\/a\u003e) or a distribution board with individual breakers.\u003c\/p\u003e\n\u003ch3\u003eSingle-Phase or Three-Phase Input\u003c\/h3\u003e\n\u003cp\u003eSchneider fits both a 3-wire single-phase (230 V) and a 5-wire three-phase (415 V) input connection; the output is single-phase 230 V in either case. Confirm which feed you intend to use when you order so the electrician can prepare the right circuit.\u003c\/p\u003e\n\u003ch3\u003eBattery Packs and Scaling Runtime\u003c\/h3\u003e\n\u003cp\u003eThe power module holds no batteries. Two SRV120RLBP2-9A packs (±120 V DC, 3U, 64 kg each) are supplied and Schneider states the UPS accepts \u003cstrong\u003eup to 10 packs\u003c\/strong\u003e, so runtime can be extended later without replacing the UPS; each additional pack adds 3U and 64 kg. \u003cstrong\u003eDo not cross-order packs between ranges:\u003c\/strong\u003e the 240 V SRV240RLBP-9A packs of the 6 and 10 kVA extended-runtime models and the 192 V modules in the SRV6KRIRK \/ SRV10KRIRK are different bus voltages and do not fit this UPS.\u003c\/p\u003e\n\u003cp\u003eSchneider publishes no runtime table for this kit that we can reproduce, so we do not print one. Tell us the load in watts and the hold-up time you need and we will calculate the pack count with the distributor.\u003c\/p\u003e\n\u003ch3\u003eRack Fit, Depth and Weight\u003c\/h3\u003e\n\u003cp\u003eBudget \u003cstrong\u003e9U\u003c\/strong\u003e plus 3U for each additional pack. The kit is 690 mm deep and each pack 686 mm, so specify an 800–1000 mm deep server rack with rear clearance for conduit. At 157 kg, check the cabinet's static load rating and fit the packs at the bottom. The rail kit pictured on Schneider's product page is the 900 mm SRVRK2, rated for 100 kg per chassis; the lighter SRVRK1 is rated for 60 kg and is not the right choice for a 64 kg pack.\u003c\/p\u003e\n\u003ch3\u003eManagement and Software\u003c\/h3\u003e\n\u003cp\u003eThe Intelligent Card Slot accepts an AP9544 Network Management Card 3 for SNMP monitoring, alerting and network shutdown. Schneider does not document a bundled shutdown software package for this model, so plan monitoring and shutdown around the management card. The APV9601 card in our catalogue is for the 1–3 kVA models and should not be ordered for this unit.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cp\u003eUPS power module, 2 x SRV120RLBP2-9A external battery packs, battery cable, rail kit, 3 x rack mounting brackets, 3 x stabilisation\/wall-mounting feet, 6 x jumper bars, USB cable, RS-232 configuration cable, user manual.\u003c\/p\u003e\n\u003ch3\u003eEasy UPS On-Line SRV 6–20 kVA Ordering Information\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-6000va-230v-with-railkit-external-battery-pack-srv6krirk\"\u003eSRV6KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kVA \/ 6 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 4U, rail kit\u003c\/td\u003e\n\u003ctd\u003e192 V battery module included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-railkit-external-battery-pack-srv10krirk\"\u003eSRV10KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA \/ 10 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 4U, rail kit\u003c\/td\u003e\n\u003ctd\u003e192 V battery module included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-6000va-rm-230v-with-extended-runtime-battery-srv6kril\"\u003eSRVPM6KRIL + SRV240RLBP-9A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kVA \/ 6 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U + 3U pack\u003c\/td\u003e\n\u003ctd\u003e240 V pack, extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-external-battery-pack-srv10krirk\"\u003eSRVPM10KRIL + SRV240RLBP-9A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA \/ 10 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U + 3U pack\u003c\/td\u003e\n\u003ctd\u003e240 V pack, extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSRV15KRILRK (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kVA \/ 15 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 9U, rail kit\u003c\/td\u003e\n\u003ctd\u003e2 x ±120 V packs, extended runtime, up to 10 packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSRV20KRILRK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kVA \/ 20 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 9U, rail kit\u003c\/td\u003e\n\u003ctd\u003e2 x ±120 V packs, extended runtime, up to 10 packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eThe 20 kVA kit, SRV20KRILRK, is being added alongside this one; ask us for it by part number.\u003c\/p\u003e\n\u003ch3\u003eAccessories and Additional Battery Packs\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV120RLBP2-9A\u003c\/td\u003e\n\u003ctd\u003eAdditional ±120 V 3U rackmount battery pack for the 15 and 20 kVA rack models, up to 10 per UPS. Being added to our catalogue — email sales@sourceit.com.sg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVRK2\u003c\/td\u003e\n\u003ctd\u003e19-inch rail kit, up to 900 mm depth, rated for 100 kg — the kit for the 3U battery packs. Being added to our catalogue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9544\u003c\/td\u003e\n\u003ctd\u003eNetwork Management Card 3 for the Intelligent Card Slot. Not currently stocked — email sales@sourceit.com.sg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU, Basic, 1U, 16 A, 230 V — one option for distributing the hardwired output to IEC-plugged equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eNeed the fuller Smart-UPS feature set at this rating? The \u003ca href=\"\/products\/apc-smart-ups-rt-15kva-230v-international-srtg15kxli\"\u003eSRTG15KXLI\u003c\/a\u003e and \u003ca href=\"\/products\/apc-smart-ups-rt-20kva-230v-international-srtg20kxli\"\u003eSRTG20KXLI\u003c\/a\u003e are the Smart-UPS RT equivalents and we stock both.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eSchneider Electric hosts the official documentation for this product. The links below are the product and document landing pages that show the correct part number.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric product page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/SRV15KRILRK\/apc-easy-ups-online-15kva-15kw-rackmount-9u-230v-hard-wire-3wire1p+n+e-outlet-intelligent-card-slot-lcd-extended-runtime-w-rail-kit\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC SRV15KRILRK on se.com\u003c\/a\u003e — Singapore site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser guide landing page\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/download\/document\/SPD_SUO-UM-990-91467_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eUser Guide Easy UPS On-Line SRV15KUXI-IN, SRV15KRIL, SRV15KRILRK, SRV20KUXI-IN, SRV20KRIL, SRV20KRILRK (990-91467)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery pack user manual landing page\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/download\/document\/SPD_EOU-UM-990-91539_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eUser Manual Easy UPS On-Line External Battery Pack SRV120RLBP2-9A (990-91539)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eSRV15KRILRK\u003c\/strong\u003e and we will send you the current PDF datasheet and user manual directly.\u003c\/p\u003e\n\u003cp\u003eThe governing document for this model is Schneider user guide 990-91467, which covers the SRV15KUXI-IN, SRV15KRIL, SRV15KRILRK, SRV20KUXI-IN, SRV20KRIL and SRV20KRILRK.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRV15KRILRK\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat is the difference between the VA and the watt rating, and how do I size this UPS?\u003c\/h3\u003e\n\u003cp\u003eVA is apparent power and watts is real power; the watt rating limits what you can connect. This model is rated at unity power factor, so 15000 VA gives a full 15000 W. Add up the continuous watts of everything you intend to protect, leave headroom for start-up surge and growth, and check the total against 15000 W — or send us the list.\u003c\/p\u003e\n\u003ch3\u003eDoes this model have IEC outlets I can plug servers into?\u003c\/h3\u003e\n\u003cp\u003eNo. The output is a hard-wire 3-wire (1P+N+E) terminal block; there are no C13 or C19 sockets and the input is hardwired too. The output feeds a rack PDU or a distribution board and a licensed electrical worker must terminate both ends. If you need a UPS you can simply plug into, look at the 1–3 kVA Easy UPS On-Line SRV models instead.\u003c\/p\u003e\n\u003ch3\u003eCan I feed it from a three-phase supply?\u003c\/h3\u003e\n\u003cp\u003eYes. Schneider fits both a 3-wire single-phase (230 V) input and a 5-wire three-phase (415 V) input connection. The output is single-phase 230 V in either case. A three-phase feed spreads the 65 A or so of input current across three phases, which is usually the easier circuit to provision. Tell us which feed you plan to use so the electrician prepares the right circuit.\u003c\/p\u003e\n\u003ch3\u003eWhat exactly is in the kit, and how much rack space does it take?\u003c\/h3\u003e\n\u003cp\u003eThe part number is a complete kit: the 3U power module, two 3U SRV120RLBP2-9A battery packs, the battery cable, the rail kit, rack brackets, stabilisation feet, jumper bars, the USB and RS-232 cables and the manual. Budget 9U. At 690 mm deep it needs an 800–1000 mm server rack, not a 600 mm comms cabinet.\u003c\/p\u003e\n\u003ch3\u003eWhat runtime will I get, and how do I extend it?\u003c\/h3\u003e\n\u003cp\u003eSchneider does not publish a runtime table for this kit that we can reproduce, so we will not print a figure. Runtime depends on the load and on the number of packs. The UPS accepts up to 10 SRV120RLBP2-9A packs, each 3U and 64 kg, so runtime scales without changing the UPS. Email sales@sourceit.com.sg with your load in watts and the hold-up time you need and we will size the pack count.\u003c\/p\u003e\n\u003ch3\u003eCan I use the battery packs from the 6 or 10 kVA Easy UPS models?\u003c\/h3\u003e\n\u003cp\u003eNo. The 6 and 10 kVA extended-runtime models run a 240 V bus (SRV240BP-9A \/ SRV240RLBP-9A) and the SRV6KRIRK \/ SRV10KRIRK use 192 V modules. This UPS runs a ±120 V bus and takes only the SRV120RLBP2-9A.\u003c\/p\u003e\n\u003ch3\u003eHow do I monitor it over the network?\u003c\/h3\u003e\n\u003cp\u003eThe Intelligent Card Slot takes an AP9544 Network Management Card 3 for SNMP monitoring, alerting and network shutdown. USB and RS-232 ports are fitted as standard. Schneider does not document a bundled shutdown software package for this model, so please do not assume PowerChute over USB — ask us and we will confirm what is supported for your build.\u003c\/p\u003e\n\u003ch3\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC SRV15KRILRK sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRV15KRILRK with a 2-year manufacturer warranty, repair or replace.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482585170084,"sku":"SRV15KRILRK","price":7709.6,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_2e7e1b1d-bb4e-41e5-8893-5631da0b153b.jpg?v=1789711357","url":"https:\/\/sourceit.com.sg\/products\/apc-easy-ups-on-line-srv-15kva-15kw-rackmount-9u-230v-extended-runtime-rail-kit-srv15krilrk","provider":"SourceIT ","version":"1.0","type":"link"}