{"product_id":"apc-easy-ups-on-line-srv-120v-3u-rackmount-battery-pack-for-15-20kva-srv120rlbp2-9a","title":"APC Easy UPS On-Line SRV 120V 3U Rackmount Battery Pack for 15\/20kVA Models","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Easy UPS On-Line SRV 120V 3U Rackmount Extended-Runtime Battery Pack for 15\/20kVA Rack Models (SRV120RLBP2-9A) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eThe Battery Pack Behind the 15 and 20 kVA Easy UPS On-Line Rack Kits\u003c\/h3\u003e\n\u003cp\u003eThe APC Easy UPS On-Line SRV120RLBP2-9A is the external battery pack for the SRV15KRILRK and SRV20KRILRK rack kits and the SRV15KRIL \/ SRV20KRIL \/ SRV15KUXI-IN \/ SRV20KUXI-IN power modules they are built on. Those UPS units carry no internal batteries at all, so every minute of hold-up time comes from packs like this one. Two are supplied in each 9U kit; this listing is the pack on its own, for adding runtime to an installed system or for replacing a pack that has reached the end of its service life.\u003c\/p\u003e\n\u003cp\u003eThe pack runs on Schneider's ±120 V DC bus — twenty sealed lead-acid blocks in a single string — and is matched to the 2340 W charger in the 15 and 20 kVA power modules. Schneider states those models accept \u003cstrong\u003eup to 10 packs\u003c\/strong\u003e, so a site that starts with the two supplied packs can add runtime in 3U steps as the load or the required hold-up time grows, without changing the UPS.\u003c\/p\u003e\n\u003ch3\u003eSizing Runtime in Singapore\u003c\/h3\u003e\n\u003cp\u003eSingapore's grid is reliable, but the outages that do occur — a substation fault, a building switchboard trip, a generator changeover that fails to synchronise — tend to last minutes rather than seconds, and a 15 or 20 kW load empties a small battery bank quickly. The usual planning question is how long the servers need to run through a graceful network shutdown, or how long until the standby generator is confirmed on load. Send us the load in watts and the hold-up time you want and we will calculate the pack count with the distributor against Schneider's runtime data.\u003c\/p\u003e\n\u003ch3\u003eRack Fit: 3U, 686 mm Deep, 64 kg — and the Right Rail Kit\u003c\/h3\u003e\n\u003cp\u003eThe pack occupies \u003cstrong\u003e3U\u003c\/strong\u003e and measures 133 x 438 x 686 mm, so it needs a server-depth cabinet of 800 mm or more with clearance behind for the battery cable. At \u003cstrong\u003e64 kg\u003c\/strong\u003e it is a two-person lift and belongs at the bottom of the rack; check the cabinet's static load rating before stacking several. Schneider lists the mounting as “rack-mounted with kit” and includes the rack mounting brackets and the battery cable in the carton.\u003c\/p\u003e\n\u003cp\u003eFor sliding support rails, the kit to specify is the 900 mm \u003cstrong\u003eSRVRK2\u003c\/strong\u003e, which is rated for 100 kg — it is the kit pictured on Schneider's page for the 15 and 20 kVA systems. The shorter SRVRK1 is rated for 60 kg and is not the right choice for a 64 kg pack.\u003c\/p\u003e\n\u003ch3\u003eSupplied Locally, with GST Invoice and Singapore Warranty\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the SRV120RLBP2-9A as an APC by Schneider Electric product with a full GST invoice and local Singapore warranty support. Schneider's printed manufacturer term is two years, repair or replace. Sealed lead-acid batteries lose life in a warm cabinet, so a comms room held close to 25 °C will get materially more service from a pack than one that sits at 35 °C. Email sales@sourceit.com.sg with your UPS part number and we will confirm the fit and the quantity before you order.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRV120RLBP2-9A Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV 120V RM Battery Pack for 15\/20kVA Rack Extended Runtime Model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRV120RLBP2-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExternal battery pack, rackmount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty, repair or replace (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eIncluded with every unit supplied by SourceIT, together with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBattery\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed lead-acid (VRLA), maintenance-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Bus Voltage\u003c\/td\u003e\n\u003ctd\u003e±120 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Blocks per String\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity (Ah \/ VAh)\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric on the product page — ask us for the runtime calculation instead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Packs per UPS\u003c\/td\u003e\n\u003ctd\u003eUp to 10 (as stated by Schneider for the SRV15KRILRK and SRV20KRILRK)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharger\u003c\/td\u003e\n\u003ctd\u003eCharged by the 2340 W charger in the 15 \/ 20 kVA power module; Schneider prints a 6-hour recharge for the kit as supplied with two packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Cartridge Part Number\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible UPS Models\u003c\/td\u003e\n\u003ctd\u003eEasy UPS On-Line SRV 15 kVA and 20 kVA rack extended-runtime models: SRV15KRILRK, SRV20KRILRK, and the SRV15KRIL \/ SRV20KRIL \/ SRV15KUXI-IN \/ SRV20KUXI-IN power modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNot Compatible With\u003c\/td\u003e\n\u003ctd\u003eThe 6 \/ 10 kVA extended-runtime models (240 V SRV240BP-9A \/ SRV240RLBP-9A), the SRV6KRIRK \/ SRV10KRIRK (192 V modules) and the 1–3 kVA models (36 V \/ 72 V packs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRail Kit\u003c\/td\u003e\n\u003ctd\u003eSRVRK2 (900 mm, 100 kg rating) — pictured by Schneider with the 15 \/ 20 kVA systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e133 x 438 x 686 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e64 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaged Dimensions (H x W x L)\u003c\/td\u003e\n\u003ctd\u003e250 x 580 x 870 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e72 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack-mounted with kit; rack mounting brackets supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e0–40 °C, 0–95% relative humidity non-condensing, 0–3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Environment\u003c\/td\u003e\n\u003ctd\u003e−15 to 40 °C, 0–95% relative humidity non-condensing, 0–15000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eBattery pack, user manual, documentation CD, battery cable, rack mounting brackets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Rack Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhich UPS Takes This Pack\u003c\/h3\u003e\n\u003cp\u003eSchneider names this pack for the 15 and 20 kVA rack extended-runtime models. In practice that means the complete kits SRV15KRILRK and SRV20KRILRK, which ship with two of these packs, and the bare power modules (SRV15KRIL, SRV20KRIL, SRV15KUXI-IN, SRV20KUXI-IN) that some regions sell separately. The pack connects through the supplied battery cable, and additional packs are chained the same way.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMatch the bus voltage.\u003c\/strong\u003e The Easy UPS On-Line SRV range uses a different battery voltage at each power level: 36 V for the 1 kVA and 72 V for the 2–3 kVA extended-runtime models, 192 V modules in the SRV6KRIRK \/ SRV10KRIRK, 240 V packs for the 6–10 kVA extended-runtime models, and ±120 V here. A pack from another level will not connect and must not be forced. If you are unsure which UPS you have, send us the part number from the label.\u003c\/p\u003e\n\u003ch3\u003eHow Many Packs\u003c\/h3\u003e\n\u003cp\u003eThe 15 and 20 kVA models accept up to 10 packs. Schneider's runtime figures are not printed on the product page, so we do not publish a table; tell us the load in watts and the hold-up time you need and we will size the bank. Remember that the charger recharges a bigger bank more slowly, so a site with frequent short outages should not over-specify packs without also planning for recovery time between them.\u003c\/p\u003e\n\u003ch3\u003eRack Fit\u003c\/h3\u003e\n\u003cp\u003eEach pack adds 3U, 686 mm of depth and 64 kg. A 600 mm comms cabinet will not take it; use an 800 mm or deeper server rack, mount the packs low, and check the static load rating when stacking several. For sliding rails use the SRVRK2 900 mm kit (100 kg rating); the SRVRK1 is limited to 60 kg.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cp\u003eBattery pack, user manual, documentation CD, battery cable, rack mounting brackets.\u003c\/p\u003e\n\u003ch3\u003eEasy UPS On-Line SRV Battery Packs and Host UPS Ordering Information\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSRV120RLBP2-9A (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±120 V, 3U, 64 kg\u003c\/td\u003e\n\u003ctd\u003eSRV15KRILRK \/ SRV20KRILRK\u003c\/td\u003e\n\u003ctd\u003eUp to 10 per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV15KRILRK\u003c\/td\u003e\n\u003ctd\u003e15 kVA \/ 15 kW, 9U kit\u003c\/td\u003e\n\u003ctd\u003eShips with 2 x SRV120RLBP2-9A\u003c\/td\u003e\n\u003ctd\u003eBeing added to our catalogue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV20KRILRK\u003c\/td\u003e\n\u003ctd\u003e20 kVA \/ 20 kW, 9U kit\u003c\/td\u003e\n\u003ctd\u003eShips with 2 x SRV120RLBP2-9A\u003c\/td\u003e\n\u003ctd\u003eBeing added to our catalogue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV240RLBP-9A\u003c\/td\u003e\n\u003ctd\u003e240 V, 3U, 63 kg\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-6000va-rm-230v-with-extended-runtime-battery-srv6kril\"\u003eSRVPM6KRIL\u003c\/a\u003e \/ \u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-external-battery-pack-srv10krirk\"\u003eSRVPM10KRIL\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003eUp to 4 per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV72RLBP-9A\u003c\/td\u003e\n\u003ctd\u003e72 V, 2U, 42.5 kg\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-battery-pack-rail-kit-srv2krilrk-e\"\u003eSRV2KRILRK-E\u003c\/a\u003e \/ \u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-battery-pack-rail-kit-srv3krilrk-e\"\u003eSRV3KRILRK-E\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003eUp to 4 per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srvl-48v-2400wh-lithium-ion-external-battery-pack-2u-srvl48rmbp2u\"\u003eSRVL48RMBP2U\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e48 V lithium-ion, 2U\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-li-ion-srvl-1000va-900w-rack-tower-4u-230v-extended-runtime-rail-kit-srvl1krilrk\"\u003eSRVL 1–3 kVA\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eLithium-ion range only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVRK2\u003c\/td\u003e\n\u003ctd\u003e19-inch rail kit, up to 900 mm depth, 100 kg rating — the rail kit for this pack. Being added to our catalogue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9544\u003c\/td\u003e\n\u003ctd\u003eNetwork Management Card 3 for the host UPS. Not currently stocked — email sales@sourceit.com.sg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eSchneider Electric hosts the official documentation for this product. The links below are the product and document landing pages that show the correct part number.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric product page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/SRV120RLBP2-9A\/apc-easy-ups-online-srv-120v-rm-battery-pack-for-15-20kva-rack-extended-runtime-model\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC SRV120RLBP2-9A on se.com\u003c\/a\u003e — Singapore site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser manual landing page\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/download\/document\/SPD_EOU-UM-990-91539_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eUser Manual Easy UPS On-Line — External Battery Pack SRV120RLBP2-9A (990-91539)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical drawing landing page\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/download\/document\/SRV120RLBP2-9A_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eSRV120RLBP2-9A — APC Easy UPS On-Line SRV 120V RM Battery Pack (dimensional drawing)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost UPS user guide landing page\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/download\/document\/SPD_SUO-UM-990-91467_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eUser Guide Easy UPS On-Line SRV15KRILRK \/ SRV20KRILRK and related models (990-91467)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eSRV120RLBP2-9A\u003c\/strong\u003e and we will send you the current PDF datasheet and user manual directly.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRV120RLBP2-9A\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhich UPS models does this pack fit?\u003c\/h3\u003e\n\u003cp\u003eThe Easy UPS On-Line SRV 15 and 20 kVA rack extended-runtime models: the SRV15KRILRK and SRV20KRILRK kits, and the SRV15KRIL \/ SRV20KRIL \/ SRV15KUXI-IN \/ SRV20KUXI-IN power modules. It runs on a ±120 V bus and does not fit the 6 \/ 10 kVA models (240 V or 192 V) or the 1–3 kVA models (36 V \/ 72 V).\u003c\/p\u003e\n\u003ch3\u003eHow many can I connect?\u003c\/h3\u003e\n\u003cp\u003eSchneider states the 15 and 20 kVA models accept up to 10 packs. The kits ship with two, so up to eight more can be added, each taking a further 3U.\u003c\/p\u003e\n\u003ch3\u003eWhat runtime does one pack give?\u003c\/h3\u003e\n\u003cp\u003eSchneider does not print a runtime figure on the product page, so we do not publish one. Runtime depends on the load and the number of packs. Send sales@sourceit.com.sg the load in watts and the hold-up time you need and we will size the bank.\u003c\/p\u003e\n\u003ch3\u003eWhat is the Ah or VAh rating?\u003c\/h3\u003e\n\u003cp\u003eSchneider does not publish an Ah or VAh figure for this pack on the product page; it lists the bus voltage (±120 V), the battery type (sealed lead-acid) and 20 blocks per string. We would rather size your runtime from Schneider's data than quote a capacity figure we cannot verify.\u003c\/p\u003e\n\u003ch3\u003eDo I need a rail kit, and which one?\u003c\/h3\u003e\n\u003cp\u003eThe carton includes rack mounting brackets and the battery cable. For sliding support rails specify the SRVRK2 900 mm kit, which is rated for 100 kg and is the kit Schneider pictures with the 15 \/ 20 kVA systems. The SRVRK1 is rated for 60 kg and is not suitable for this 64 kg pack.\u003c\/p\u003e\n\u003ch3\u003eWill it fit a 600 mm deep cabinet?\u003c\/h3\u003e\n\u003cp\u003eNo. The pack is 686 mm deep before the battery cable, so it needs an 800 mm or deeper server rack. Mount it low and check the rack's static load rating — each pack is 64 kg.\u003c\/p\u003e\n\u003ch3\u003eCan I replace the batteries inside the pack?\u003c\/h3\u003e\n\u003cp\u003eSchneider does not publish a replacement cartridge part number for this pack, so the documented replacement is the complete pack. Ask us if you have a pack that needs renewal and we will confirm the current service option with the distributor.\u003c\/p\u003e\n\u003ch3\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC SRV120RLBP2-9A sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRV120RLBP2-9A with a 2-year manufacturer warranty, repair or replace.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482586644644,"sku":"SRV120RLBP2-9A","price":1789.4,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_4def9d53-469b-4c0e-8d55-2f2907edde98.jpg?v=1789711557","url":"https:\/\/sourceit.com.sg\/products\/apc-easy-ups-on-line-srv-120v-3u-rackmount-battery-pack-for-15-20kva-srv120rlbp2-9a","provider":"SourceIT ","version":"1.0","type":"link"}