{"product_id":"apc-easy-ups-on-line-srv-1000va-900w-tower-230v-srv1ki-e","title":"APC Easy UPS On-Line SRV 1000VA 900W Tower UPS 230V","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Easy UPS On-Line SRV 1000VA\/900W Tower UPS 230V (SRV1KI-E) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eOn-Line Double Conversion for Singapore's 230V\/50Hz Supply\u003c\/h3\u003e\n\u003cp\u003eThe APC Easy UPS On-Line SRV1KI-E is a true double-conversion on-line UPS rated at 1000 VA \/ 900 W in a compact tower. The load runs from the inverter continuously, on a clean 230 V sine wave with 3% maximum distortion, rather than waiting on a transfer when the mains misbehaves.\u003c\/p\u003e\n\u003cp\u003eFor a Singapore office, clinic or small comms room that means the everyday problems — voltage sag during a storm, a brownout on a loaded riser, switching transients from lift or air-conditioning plant — are absorbed by the rectifier rather than passed to your equipment, and the battery is held in reserve for a real outage. The input stage accepts anything from 180 V to 285 V at full load without touching the battery, which is a far wider window than a line-interactive UPS offers.\u003c\/p\u003e\n\u003ch3\u003e0.9 Power Factor — More Real Watts per kVA\u003c\/h3\u003e\n\u003cp\u003eThe -E generation is the 0.9 power factor build of the Easy UPS On-Line SRV range, and that is the main reason to choose it: the SRV1KI-E delivers 900 W from 1000 VA, where the earlier SRV1KI delivers 800 W from the same VA rating. When you are sizing against a tower server, a NAS, a small switch stack or a point-of-sale back office, watts are the number that decides whether the UPS copes.\u003c\/p\u003e\n\u003cp\u003eSize on the total continuous watts of the connected load with headroom for start-up surge, and talk to us if you are close to the limit — we would rather size it right than have it trip.\u003c\/p\u003e\n\u003ch3\u003eA Small Tower That Sits Beside the Equipment\u003c\/h3\u003e\n\u003cp\u003eAt 223 mm high, 145 mm wide and 288 mm deep, and 9.6 kg, the SRV1KI-E is a genuine desk-side or floor-standing unit. It needs no rack, no rails and no lifting help, which makes it the natural choice where the load is one server or a wall-mounted comms panel rather than a cabinet. It is not rack-mountable; if you need the same 1 kVA rating on rails, the SRV1KRIRK-E is the 2U rackmount build.\u003c\/p\u003e\n\u003cp\u003eAudible noise is 50 dBA, so it is acceptable in a back office but is not a silent unit — place it in a store room or comms cupboard rather than on a shared desk if that matters.\u003c\/p\u003e\n\u003ch3\u003eOutlets, Power Cord and Network Management\u003c\/h3\u003e\n\u003cp\u003eOutput is provided on 3 x IEC C13, so ordinary IEC power leads plug straight in — no electrician and no hardwiring required. Input is a standard IEC C14 inlet. The input lead in the carton is an IEC C13 to Schuko (CEE 7\/7) cable, which does not fit Singapore's BS 1363 (Type G) wall sockets. The normal solution here is a BS 1363 to IEC C13 lead, which plugs into the unit's C14 inlet, or feeding the UPS from an IEC-outlet rack PDU. Neither is bundled; ask us if you need one.\u003c\/p\u003e\n\u003cp\u003eThe -E generation adds an Emergency Power Off connector, using normally-closed contacts, which the earlier non-E models do not have — a genuine advantage where a room EPO loop is a condition of occupancy. An Intelligent Card Slot takes an AP9544 Network Management Card 3 for SNMP monitoring, and PowerChute Serial Shutdown handles graceful unattended shutdown over USB or serial.\u003c\/p\u003e\n\u003ch3\u003eSupplied Locally, with GST Invoice and Singapore Warranty\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the SRV1KI-E as an APC by Schneider Electric product with a full GST invoice and local Singapore warranty support. APC's manufacturer term for the Easy UPS On-Line SRV range is two years, repair or replace, applied worldwide with no separate European figure.\u003c\/p\u003e\n\u003cp\u003eNot sure whether you need the -E build, the earlier non-E model, the rackmount version or an extended-runtime model? Email sales@sourceit.com.sg with your load and the runtime you need and we will size it for you.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRV1KI-E Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line, 1000VA\/900W, Tower, 230V, 3x IEC C13 outlets, Intelligent Card Slot, LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRV1KI-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV, -E generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower, free-standing (not rack-mountable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eIncluded with every unit supplied by SourceIT, together with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eOutput\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 900 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Factor\u003c\/td\u003e\n\u003ctd\u003e0.9 — the -E generation delivers more real watts than the 0.8 power factor of the earlier non-E SRV models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V, configurable to 220 V \/ 230 V \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±3 Hz synchronised to mains; ±0.1 Hz on battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Distortion\u003c\/td\u003e\n\u003ctd\u003e3% maximum (linear load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e3 x IEC C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e88% at full load in double conversion; up to 94% in ECO mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e945 joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bypass\u003c\/td\u003e\n\u003ctd\u003eAutomatic and manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for the -E generation — the load is fed continuously from the inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInput\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (full load)\u003c\/td\u003e\n\u003ctd\u003e180–285 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (reduced load)\u003c\/td\u003e\n\u003ctd\u003e110–285 V AC at half load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Circuit Breaker\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBatteries \u0026amp; Runtime\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed maintenance-free lead-acid (VRLA), 12 V 9 Ah blocks, 3 to 5 year typical service life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Bus Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (2 x 12 V 9 Ah)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBCV203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Battery Packs\u003c\/td\u003e\n\u003ctd\u003eNot supported on this model. The extended-runtime SRV1KRILRK-E, SRV2KRILRK-E and SRV3KRILRK-E are the models documented to take the SRV36RLBP-9A \/ SRV72RLBP-9A packs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Load\u003c\/td\u003e\n\u003ctd\u003eSchneider's range brochure prints 10 minutes at half load and 3 minutes at full load; runtime depends on the connected load — ask us for a sizing calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCommunications \u0026amp; Management\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eUSB (Type B), RS-232 serial, EPO connector, Intelligent Card Slot (1 slot, free)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes — EPO connector with normally-closed contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Panel\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD with LED status indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eOptional AP9544 Network Management Card 3, fitted in the Intelligent Card Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutdown Software\u003c\/td\u003e\n\u003ctd\u003ePowerChute Serial Shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e223 x 145 x 288 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e9.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e10.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e50 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e380 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eBlack, RAL 7010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e0–40 °C, 0–95% relative humidity non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003eRated load up to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−20 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, TISI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 62040-1:2019\/A11:2021; EN\/IEC 62040-2:2018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eIEC C13 to Schuko input cable, IEC C13 to C14 cable, USB cable, RS-232 serial cable, PowerChute Serial Shutdown software, front bezel, user documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eOutlets and What Can Be Plugged In\u003c\/h3\u003e\n\u003cp\u003eThe SRV1KI-E provides \u003cstrong\u003e3 x IEC C13\u003c\/strong\u003e on the output. Standard IEC leads plug straight in, so no electrician is needed for the load side. Three outlets is enough for a server, its monitor and a switch, or a NAS plus a router and a modem; if you need more, an IEC C14-to-multiple-C13 splitter or a small IEC-outlet PDU on one of the C13 sockets is the usual answer, provided the total stays inside 900 W.\u003c\/p\u003e\n\u003cp\u003eSize on watts, not on VA. This unit is a 0.9 power factor build rated at 900 W. Add up the continuous draw of everything you intend to connect, leave headroom for start-up surge, and check the total against that figure. We are happy to do the sum for you.\u003c\/p\u003e\n\u003ch3\u003ePlacement\u003c\/h3\u003e\n\u003cp\u003eThe chassis is a tower measuring 223 x 145 x 288 mm and weighing 9.6 kg. It stands vertically on its own feet with the supplied front bezel and is not designed for rack mounting. Leave clear space at the rear and sides for the cooling fan, and keep it off carpet where dust builds up; a shelf in a comms cupboard or the floor of a plant room beside the equipment is ideal.\u003c\/p\u003e\n\u003ch3\u003eBattery and Runtime\u003c\/h3\u003e\n\u003cp\u003eThe battery is a sealed maintenance-free VRLA type — two 12 V 9 Ah blocks on a 24 V bus — with a typical three to five year service life in normal conditions. Singapore's humidity and ambient temperature both shorten battery life, so a room that stays close to 25 °C will get materially more service out of a battery than one that sits at 35 °C. The replacement cartridge for this model is \u003cstrong\u003eAPCRBCV203\u003c\/strong\u003e — note that the -E generation uses different cartridge part numbers from the earlier non-E models, so check the part number against your actual unit before ordering.\u003c\/p\u003e\n\u003cp\u003eSchneider's range brochure prints 10 minutes at half load and 3 minutes at full load — enough for a graceful shutdown, not for continued working. For tens of minutes, look at the SRV1KRILRK-E extended-runtime model. Send us your load in watts and the hold-up time you need and we will size it for you.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cp\u003eIEC C13 to Schuko input cable, IEC C13 to C14 cable, USB cable, RS-232 serial cable, PowerChute Serial Shutdown software, front bezel, user documentation\u003c\/p\u003e\n\u003ch3\u003eEasy UPS On-Line SRV -E Range Ordering Information\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSRV1KI-E (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kVA \/ 900 W\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003ctd\u003e3 x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-1800w-230v-srv2ki-e\"\u003eSRV2KI-E\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kVA \/ 1800 W\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003ctd\u003e4 x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-2700w-230v-srv3ki-e\"\u003eSRV3KI-E\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kVA \/ 2700 W\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003ctd\u003e6 x C13, 1 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV1KRIRK-E\u003c\/td\u003e\n\u003ctd\u003e1 kVA \/ 900 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U, rail kit\u003c\/td\u003e\n\u003ctd\u003e3 x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-rm-2000va-1800w-230v-with-rail-kit-srv2krirk-e\"\u003eSRV2KRIRK-E\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kVA \/ 1800 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U, rail kit\u003c\/td\u003e\n\u003ctd\u003e4 x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV3KRI-E\u003c\/td\u003e\n\u003ctd\u003e3 kVA \/ 2700 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U, without rail kit\u003c\/td\u003e\n\u003ctd\u003e6 x C13, 1 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-rm-3000va-2700w-230v-with-rail-kit-srv3krirk-e\"\u003eSRV3KRIRK-E\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kVA \/ 2700 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U, rail kit\u003c\/td\u003e\n\u003ctd\u003e6 x C13, 1 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-battery-pack-rail-kit-srv1krilrk-e\"\u003eSRV1KRILRK-E\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kVA \/ 900 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 4U, rail kit\u003c\/td\u003e\n\u003ctd\u003e4 x C13, extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-battery-pack-rail-kit-srv2krilrk-e\"\u003eSRV2KRILRK-E\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kVA \/ 1800 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 4U, rail kit\u003c\/td\u003e\n\u003ctd\u003e4 x C13, extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-battery-pack-rail-kit-srv3krilrk-e\"\u003eSRV3KRILRK-E\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kVA \/ 2700 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 4U, rail kit\u003c\/td\u003e\n\u003ctd\u003e6 x C13, 1 x C19, extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eReplacement Battery Cartridges\u003c\/h3\u003e\n\u003cp\u003eThe -E generation uses the APCRBCV cartridge series. Cartridge numbers differ between the tower and rackmount builds and between generations, so match the cartridge to the exact part number on your unit.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPCRBCV203\u003c\/td\u003e\n\u003ctd\u003eReplacement cartridge for the SRV1KI-E tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPCRBCV204\u003c\/td\u003e\n\u003ctd\u003eReplacement cartridge for the SRV2KI-E tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPCRBCV205\u003c\/td\u003e\n\u003ctd\u003eReplacement cartridge for the SRV3KI-E tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPCRBCV200\u003c\/td\u003e\n\u003ctd\u003eReplacement cartridge for the SRV1KRIRK-E rackmount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPCRBCV201\u003c\/td\u003e\n\u003ctd\u003eReplacement cartridge for the SRV2KRIRK-E rackmount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPCRBCV202\u003c\/td\u003e\n\u003ctd\u003eReplacement cartridge for the SRV3KRI-E and SRV3KRIRK-E rackmount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9544\u003c\/td\u003e\n\u003ctd\u003eNetwork Management Card 3 for the Intelligent Card Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eWe do not hold these cartridges in stock — email sales@sourceit.com.sg with your part number and we will source it.\u003c\/p\u003e\n\u003ch3\u003eThe Earlier Non-E Models\u003c\/h3\u003e\n\u003cp\u003eThe earlier 0.8 power factor generation is also in our catalogue: fewer real watts per kVA and no EPO connector, but a sound choice where neither matters.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-230v-srv1ki\"\u003eSRV1KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kVA \/ 800 W\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-srv2ki\"\u003eSRV2KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kVA \/ 1600 W\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-srv3ki\"\u003eSRV3KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kVA \/ 2400 W\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri\"\u003eSRV1KRI + SRVRK1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kVA \/ 800 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri\"\u003eSRV2KRI + SRVRK1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kVA \/ 1600 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri\"\u003eSRV3KRI + SRVRK1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kVA \/ 2400 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eSchneider Electric hosts the official documentation for this product. The links below are the Schneider Electric product page for this exact part number and the landing page for the user manual that covers it.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric product page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/SRV1KI-E\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC SRV1KI-E on se.com\u003c\/a\u003e — Singapore site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser manual landing page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/au\/en\/download\/document\/SPD_EUO-UM-990-91498_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eUser Manual Easy UPS On-Line SRV1KI-E, SRV2KI-E, SRV3KI-E, SRV1KRI-E, SRV2KRI-E, SRV3KRI-E (EUO-UM-990-91498A)\u003c\/a\u003e — Schneider Electric document landing page, English\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eSRV1KI-E\u003c\/strong\u003e and we will send you the current PDF datasheet and user manual directly.\u003c\/p\u003e\n\u003cp\u003eThe governing document for the standard -E models is Schneider user manual EUO-UM-990-91498A-MN01_EN.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRV1KI-E\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat is the difference between the VA and the watt rating, and how do I size this UPS?\u003c\/h3\u003e\n\u003cp\u003eVA is apparent power and watts is real power; the watt rating is what limits your load. The -E generation is a 0.9 power factor build, so this model gives 900 W from 1000 VA — more real power than the earlier SRV1KI, which gives 800 W. Total up the continuous watts of everything you want to protect, allow headroom for start-up surge and growth, and compare that to 900 W.\u003c\/p\u003e\n\u003ch3\u003eWhat does the “-E” suffix actually change?\u003c\/h3\u003e\n\u003cp\u003eThree things that matter. The output power factor rises from 0.8 to 0.9, so you get more real watts from the same VA rating. An Emergency Power Off connector is fitted, which the non-E models do not have. And the replacement battery cartridge part number changes — APCRBCV203 for this model — so a cartridge from a non-E unit is not the right part for an -E unit. Everything else — on-line double conversion, the two-year warranty, the Intelligent Card Slot — carries over.\u003c\/p\u003e\n\u003ch3\u003eWill the supplied power cord plug into a Singapore wall socket?\u003c\/h3\u003e\n\u003cp\u003eNo. The input lead in the box is a Schuko (CEE 7\/7) plug to IEC C13, which is the continental European type and does not fit a BS 1363 Type G socket. You need a BS 1363 to IEC C13 lead, which plugs straight into the unit's C14 inlet, or you feed the UPS from an IEC-outlet rack PDU. Neither is included in the carton; ask us and we can quote one.\u003c\/p\u003e\n\u003ch3\u003eWhat runtime will I get?\u003c\/h3\u003e\n\u003cp\u003eSchneider's brochure for the range prints 10 minutes at half load and 3 minutes at full load, and the datasheet gives a maximum of 3 minutes. Runtime falls sharply as load rises, so a 300 W load will run considerably longer than a 900 W one. Email sales@sourceit.com.sg with your load in watts and the hold-up time you need and we will size it against the manufacturer's runtime curve.\u003c\/p\u003e\n\u003ch3\u003eWhich replacement battery cartridge does it take, and can I change it myself?\u003c\/h3\u003e\n\u003cp\u003eThis model takes the \u003cstrong\u003eAPCRBCV203\u003c\/strong\u003e cartridge, a 24 V pack made up of two 12 V 9 Ah blocks. Schneider describes the batteries as user replaceable. Plan on a short shutdown window for a battery change unless we confirm otherwise for your build. Because the -E cartridge numbers differ from the non-E ones, always check the part number printed on the unit before ordering.\u003c\/p\u003e\n\u003ch3\u003eCan I mount it in a rack?\u003c\/h3\u003e\n\u003cp\u003eNo — the SRV1KI-E is a tower-only chassis with no rack ears or rail option. If you need the same 1000 VA \/ 900 W rating in a cabinet, the SRV1KRIRK-E is the 2U rackmount build with the rails in the box, and the SRV1KRILRK-E is the 4U extended-runtime rackmount build.\u003c\/p\u003e\n\u003ch3\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC SRV1KI-E sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRV1KI-E with a 2-year manufacturer warranty, repair or replace.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bzQk-YuLvCM\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482393346212,"sku":"SRV1KI-E","price":469.2,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_9ab076d1-2296-447e-965f-a0bed263aad6.jpg?v=1789701472","url":"https:\/\/sourceit.com.sg\/products\/apc-easy-ups-on-line-srv-1000va-900w-tower-230v-srv1ki-e","provider":"SourceIT ","version":"1.0","type":"link"}