{"product_id":"apc-easy-ups-on-line-li-ion-srvl-6kva-6kw-rack-tower-5u-230v-extended-runtime-rail-kit-srvl6krilrk","title":"APC Easy UPS On-Line Li-Ion SRVL 6kVA 6kW Rack\/Tower 5U 230V Extended Runtime","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Easy UPS On-Line Li-Ion SRVL 6kVA\/6kW Rack\/Tower 5U 230V Extended Runtime with Rail Kit (SRVL6KRILRK) - 3 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003e6 kVA \/ 6 kW On-Line Double Conversion with a Lithium-Ion Pack\u003c\/h3\u003e\n\u003cp\u003eThe APC Easy UPS On-Line Li-Ion SRVL6KRILRK is the 6 kVA model of the lithium-ion Easy UPS On-Line range, rated at \u003cstrong\u003e6 kVA \/ 6 kW\u003c\/strong\u003e — a unity power factor build, so the full 6000 W is available to the load. It is supplied as a complete extended-runtime kit: a 2U power module, a 3U SRVL48RMBP3U lithium-ion battery pack (48 V, 4800 Wh) and the rail kit, occupying \u003cstrong\u003e5U\u003c\/strong\u003e in total. The load runs from the inverter continuously on a 230 V sine wave, with the rectifier absorbing the sags, brownouts and switching transients of a loaded Singapore riser.\u003c\/p\u003e\n\u003cp\u003eAt this rating the SRVL6KRILRK is a hardwired product: input and output are a single 1P+N+E hardwire connection each, so it is installed by a licensed electrical worker on a dedicated circuit and normally feeds a rack PDU rather than individual IEC leads. That is the same arrangement as the lead-acid \u003ca href=\"\/products\/apc-easy-ups-srv-rm-6000va-230v-with-railkit-external-battery-pack-srv6krirk\"\u003eSRV6KRIRK\u003c\/a\u003e it sits alongside in our catalogue.\u003c\/p\u003e\n\u003ch3\u003eWhy Lithium-Ion at 6 kVA\u003c\/h3\u003e\n\u003cp\u003eA 6 kVA lead-acid UPS carries a heavy VRLA bank that needs replacing every three to five years in a warm Singapore plant room, and each replacement is a lift-and-swap job on a live rack. Schneider Electric describes the SRVL lithium-ion battery as minimising the need to replace the battery during the UPS lifetime, and backs it with a five-year repair-or-replace warranty on the battery against three years on the UPS itself. Fewer battery cycles, less weight per watt-hour and a smaller footprint are the practical gains.\u003c\/p\u003e\n\u003ch3\u003eScalable Runtime with SRVL48RMBP3U Packs\u003c\/h3\u003e\n\u003cp\u003eSchneider Electric's product page states that up to three external SRVL48RMBP3U packs can be added to this model for extended runtime. Each pack is a 3U, 48 V, 4800 Wh unit, so a rack with one power module and the maximum pack count is a serious runtime installation rather than a ride-through UPS. Runtime figures for this model are not printed on the Schneider product page, so we do not print them here; send us your load and hold-up time and we will size it from the manufacturer's runtime data.\u003c\/p\u003e\n\u003ch3\u003e5U Rack\/Tower Convertible, Rails Included\u003c\/h3\u003e\n\u003cp\u003eThe kit occupies \u003cstrong\u003e5U\u003c\/strong\u003e and measures 217 x 438 x 685 mm assembled, with a net weight of 69.2 kg. The rail kit and stabilisation feet are in the carton, so the module and pack can be racked or stood as a tower without a separate order. At 685 mm deep it needs a proper server cabinet — 1000 mm or 1070 mm deep — rather than a comms cabinet.\u003c\/p\u003e\n\u003ch3\u003eIntelligent Card Slot, EPO and PowerChute\u003c\/h3\u003e\n\u003cp\u003eThe power module carries a multifunction LCD and an Intelligent Card Slot that takes the optional AP9544 Network Management Card 3 for SNMP monitoring and alerting; Schneider Electric also lists Modbus and dry-contact cards for the slot. Graceful shutdown of servers and workstations is handled by PowerChute over USB or serial, as Schneider's product page describes.\u003c\/p\u003e\n\u003ch3\u003eSupplied Locally, with GST Invoice and Singapore Warranty\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the SRVL6KRILRK as an APC by Schneider Electric product with a full GST invoice and local Singapore warranty support. Schneider Electric's printed term for this model is three years repair or replace on the UPS and five years repair or replace on the lithium-ion battery. Because the unit is hardwired, we can also introduce a licensed electrical contractor for the installation if you do not have one.\u003c\/p\u003e\n\u003cp\u003eEmail sales@sourceit.com.sg with your load in watts, the runtime you need and the cabinet you intend to use, and we will confirm the configuration and send the current Schneider datasheet.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRVL6KRILRK Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line, 6kVA\/6kW, Lithium-ion, Rack\/Tower 5U, 230V, 1 Hard wire (1P+N+E) outlet, Intelligent Card Slot, Extended runtime, W\/ rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRVL6KRILRK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit Composition\u003c\/td\u003e\n\u003ctd\u003e2U lithium-ion power module, 3U SRVL48RMBP3U battery pack (48 V, 4800 Wh) and rail kit — 5U in total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line Lithium-ion SRVL, extended-runtime models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eRack\/Tower convertible, 5U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e3 years UPS, 5 years lithium-ion battery — repair or replace (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eIncluded with every unit supplied by SourceIT, together with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eOutput\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e6 kVA \/ 6 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Factor\u003c\/td\u003e\n\u003ctd\u003e1.0 — the full 6000 W is available to the load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connection\u003c\/td\u003e\n\u003ctd\u003e1 x hardwire, 1P+N+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric on the product page — ask us and we will confirm from the current datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric on the product page — ask us and we will confirm from the current datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bypass\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric on the product page — ask us and we will confirm from the current datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric — the load is fed continuously from the inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInput\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003e1 x hardwire, 1P+N+E — installed by a licensed electrical worker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric on the product page — ask us and we will confirm from the current datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric on the product page — ask us and we will confirm from the current datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBatteries \u0026amp; Runtime\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLithium-ion — Schneider Electric describes it as minimising the need to replace the battery during the UPS lifetime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Pack\u003c\/td\u003e\n\u003ctd\u003eSRVL48RMBP3U — 48 V, 4800 Wh, 3U rackmount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Bus Voltage\u003c\/td\u003e\n\u003ctd\u003e48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Battery Packs\u003c\/td\u003e\n\u003ctd\u003eUp to three external SRVL48RMBP3U packs, as stated on Schneider Electric's product page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric on the product page — ask us and we will confirm from the current datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Load\u003c\/td\u003e\n\u003ctd\u003eNot published on the Schneider Electric product page — ask us for a sizing calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCommunications \u0026amp; Management\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eIntelligent Card Slot (1 slot, free); USB and serial for PowerChute as described on Schneider's product page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Panel\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eOptional AP9544 Network Management Card 3 for the Intelligent Card Slot; Modbus and dry-contact cards also listed by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutdown Software\u003c\/td\u003e\n\u003ctd\u003ePowerChute — graceful shutdown of servers and workstations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric on the product page — ask us and we will confirm from the current datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e5U (2U power module + 3U battery pack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e217 x 438 x 685 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e69.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric on the product page — ask us and we will confirm from the current datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack or tower; rail kit and stabilisation feet included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric on the product page — ask us and we will confirm from the current datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric on the product page — ask us and we will confirm from the current datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAs printed on the current Schneider Electric datasheet — ask us for the PDF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003ePower module, SRVL48RMBP3U battery pack, rail kit, stabilisation feet and documentation; the full cable list is on the Schneider datasheet we can send you\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eHardwired Input and Output\u003c\/h3\u003e\n\u003cp\u003eThe SRVL6KRILRK has a single 1P+N+E hardwire connection for input and another for output. There are no IEC outlets on the UPS itself; the output normally feeds one or more rack PDUs — for example a switched \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e or a basic \u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559\u003c\/a\u003e — and the IEC leads for the servers plug into those. Installation must be done by a licensed electrical worker on a dedicated circuit sized for 6 kW plus battery charging. Because the input is hardwired there is no plug type to worry about for Singapore.\u003c\/p\u003e\n\u003ch3\u003eSizing\u003c\/h3\u003e\n\u003cp\u003eThis is a unity power factor build, so size directly on watts: add up the continuous draw of everything downstream of the UPS, allow headroom for start-up surge and growth, and compare it with 6000 W. If you are close to the limit, the 10 kVA lead-acid \u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-railkit-external-battery-pack-srv10krirk\"\u003eSRV10KRIRK\u003c\/a\u003e is the next step in the Easy UPS On-Line range.\u003c\/p\u003e\n\u003ch3\u003eRack Fit\u003c\/h3\u003e\n\u003cp\u003eThe assembled kit occupies \u003cstrong\u003e5U\u003c\/strong\u003e at 217 x 438 x 685 mm and weighs 69.2 kg net, so it belongs at the bottom of a 1000 mm or 1070 mm deep server cabinet with the rail kit supplied. Plan for two people or a lift for installation. Each additional SRVL48RMBP3U pack is a further 3U.\u003c\/p\u003e\n\u003ch3\u003eBattery and Runtime\u003c\/h3\u003e\n\u003cp\u003eThe SRVL48RMBP3U is a 48 V, 4800 Wh lithium-ion pack — twice the energy of the 2U pack used on the 1 to 3 kVA SRVL kits. Schneider Electric's product page states up to three external packs can be added. Runtime and recharge figures are not printed on the product page, so we do not print them; send us your load and the hold-up time you need and we will size the pack count from the manufacturer's data.\u003c\/p\u003e\n\u003ch3\u003eManagement and Software\u003c\/h3\u003e\n\u003cp\u003eAn Intelligent Card Slot takes the optional AP9544 Network Management Card 3 for SNMP monitoring; Modbus and dry-contact cards are also listed by Schneider Electric. PowerChute provides graceful shutdown of servers and workstations.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRVL Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cp\u003ePower module, SRVL48RMBP3U lithium-ion battery pack, rail kit, stabilisation feet and documentation. Ask us for the current Schneider datasheet for the full cable list.\u003c\/p\u003e\n\u003ch3\u003eEasy UPS On-Line Lithium-ion SRVL Range Ordering Information\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVL1KRILRK (ask us)\u003c\/td\u003e\n\u003ctd\u003e1 kVA \/ 900 W\u003c\/td\u003e\n\u003ctd\u003eRack\/Tower 4U, rails included\u003c\/td\u003e\n\u003ctd\u003e6 x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVL2KRILRK (ask us)\u003c\/td\u003e\n\u003ctd\u003e2 kVA \/ 1800 W\u003c\/td\u003e\n\u003ctd\u003eRack\/Tower 4U, rails included\u003c\/td\u003e\n\u003ctd\u003e6 x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVL3KRILRK (ask us)\u003c\/td\u003e\n\u003ctd\u003e3 kVA \/ 2700 W\u003c\/td\u003e\n\u003ctd\u003eRack\/Tower 4U, rails included\u003c\/td\u003e\n\u003ctd\u003e6 x C13, 1 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSRVL6KRILRK (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kVA \/ 6 kW\u003c\/td\u003e\n\u003ctd\u003eRack\/Tower 5U, rails included\u003c\/td\u003e\n\u003ctd\u003eHardwire 1P+N+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVL48RMBP3U (ask us)\u003c\/td\u003e\n\u003ctd\u003e48 V, 4800 Wh battery pack\u003c\/td\u003e\n\u003ctd\u003e3U\u003c\/td\u003e\n\u003ctd\u003eFor this 6 kVA model, up to three\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVL48RMBP2U (ask us)\u003c\/td\u003e\n\u003ctd\u003e48 V, 2400 Wh battery pack\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003ctd\u003eFor the 1, 2 and 3 kVA kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9544\u003c\/td\u003e\n\u003ctd\u003eNetwork Management Card 3 for the Intelligent Card Slot — ask us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVL48RMBP3U\u003c\/td\u003e\n\u003ctd\u003eAdditional 48 V, 4800 Wh lithium-ion battery pack, 3U — up to three per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1U switched rack PDU, 16 A, 8 x C13 — a typical output distribution for a hardwired UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1U basic rack PDU, 16 A — output distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eThe Lead-Acid 6 kVA and 10 kVA Easy UPS On-Line SRV Models\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-6000va-230v-with-railkit-external-battery-pack-srv6krirk\"\u003eSRV6KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kVA\u003c\/td\u003e\n\u003ctd\u003eRackmount, VRLA battery pack and rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-6000va-rm-230v-with-extended-runtime-battery-srv6kril\"\u003eSRVPM6KRIL + SRV240RLBP-9A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kVA\u003c\/td\u003e\n\u003ctd\u003eRackmount, extended runtime VRLA pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-railkit-external-battery-pack-srv10krirk\"\u003eSRV10KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA\u003c\/td\u003e\n\u003ctd\u003eRackmount, VRLA battery pack and rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eSchneider Electric hosts the official documentation for this product. The links below are the Schneider Electric pages for this part number; each one names the correct model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric product page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/il\/en\/product\/SRVL6KRILRK\/apc-easy-ups-online-6kva-6kw-lithiumion-rack-tower-5u-230v-1-hard-wire-1p+n+e-outlet-intelligent-card-slot-extended-runtime-w-rail-kit\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC SRVL6KRILRK on se.com\u003c\/a\u003e — Israel (English) site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrochure, APC Easy UPS On-Line Lithium-Ion SRVL 230V Extended Runtime\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/uk\/en\/download\/document\/SPD_SRVL_230V_Brochure_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider document SPD_SRVL_230V_Brochure_EN\u003c\/a\u003e — document landing page, UK site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eSRVL6KRILRK\u003c\/strong\u003e and we will send you the current PDF datasheet and user manual directly.\u003c\/p\u003e\n\u003cp\u003eThe 6 kVA model has its own user manual (Schneider reference SPD_EU_UM_TME19612_EN) and the SRVL48RMBP3U pack its own guide (SPD_EU_UM_TME19702_EN); email us and we will send both.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRVL6KRILRK\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eDoes the SRVL6KRILRK have IEC outlets?\u003c\/h3\u003e\n\u003cp\u003eNo. Input and output are each a single 1P+N+E hardwire connection. The output normally feeds a rack PDU, and your equipment plugs into the PDU. A licensed electrical worker installs the UPS on a dedicated circuit.\u003c\/p\u003e\n\u003ch3\u003eWhat is included in the kit?\u003c\/h3\u003e\n\u003cp\u003eA 2U lithium-ion power module, a 3U SRVL48RMBP3U battery pack (48 V, 4800 Wh) and the rail kit with stabilisation feet — 5U in total, 217 x 438 x 685 mm and 69.2 kg.\u003c\/p\u003e\n\u003ch3\u003eHow do I size it?\u003c\/h3\u003e\n\u003cp\u003eThis is a 6 kVA \/ 6 kW unity power factor build, so compare the continuous watts of your load, with headroom for surge and growth, directly against 6000 W.\u003c\/p\u003e\n\u003ch3\u003eWhat runtime will I get, and can I add packs?\u003c\/h3\u003e\n\u003cp\u003eSchneider Electric's product page states up to three external SRVL48RMBP3U packs can be added. Runtime figures are not printed on the product page, so we do not print them; send us your load and hold-up time and we will size the pack count from the manufacturer's data.\u003c\/p\u003e\n\u003ch3\u003eIs the battery user replaceable?\u003c\/h3\u003e\n\u003cp\u003eThe battery is an external 3U pack connected by cable rather than a cartridge inside the UPS, and Schneider Electric describes the lithium-ion battery as minimising the need to replace the battery during the UPS lifetime. Schneider Electric does not describe changing the pack with the load running, so plan a maintenance window for any pack change.\u003c\/p\u003e\n\u003ch3\u003eHow do I monitor it and shut servers down?\u003c\/h3\u003e\n\u003cp\u003eThe Intelligent Card Slot takes the optional AP9544 Network Management Card 3 for SNMP; PowerChute handles graceful shutdown of servers and workstations.\u003c\/p\u003e\n\u003ch3\u003eWhich cabinet does it fit?\u003c\/h3\u003e\n\u003cp\u003eAt 685 mm deep and 69.2 kg it belongs in a 1000 mm or 1070 mm deep server cabinet with the supplied rail kit, mounted low. It is not a comms-cabinet product.\u003c\/p\u003e\n\u003ch3\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC SRVL6KRILRK sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs the SRVL6KRILRK with a three-year manufacturer warranty on the UPS and a five-year manufacturer warranty on the lithium-ion battery.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482415366308,"sku":"SRVL6KRILRK","price":7222.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_be7e6697-668e-4866-9427-fee25696427f.jpg?v=1789701510","url":"https:\/\/sourceit.com.sg\/products\/apc-easy-ups-on-line-li-ion-srvl-6kva-6kw-rack-tower-5u-230v-extended-runtime-rail-kit-srvl6krilrk","provider":"SourceIT ","version":"1.0","type":"link"}