{"product_id":"apc-easy-ups-on-line-li-ion-srvl-3000va-2700w-rack-tower-4u-230v-extended-runtime-rail-kit-srvl3krilrk","title":"APC Easy UPS On-Line Li-Ion SRVL 3000VA Rack\/Tower 4U 230V Extended Runtime","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Easy UPS On-Line Li-Ion SRVL 3000VA\/2700W Rack\/Tower 4U 230V Extended Runtime with Rail Kit (SRVL3KRILRK) - 3 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eOn-Line Double Conversion with a Lithium-Ion Battery Pack\u003c\/h3\u003e\n\u003cp\u003eThe APC Easy UPS On-Line Li-Ion SRVL3KRILRK is a true double-conversion on-line UPS rated at 3000 VA \/ 2700 W, supplied as a complete extended-runtime kit: the 2U SRVLPM3KRIL power module, one 2U SRVL48RMBP2U lithium-ion battery pack (48 V, 2400 Wh) and two SRVRK1 rail kits, occupying \u003cstrong\u003e4U\u003c\/strong\u003e of rack space in total. The load runs from the inverter continuously on a clean 230 V sine wave, so voltage sag, brownout and switching transients on a Singapore riser are absorbed by the rectifier rather than passed to your servers, and the battery is held in reserve for a genuine outage.\u003c\/p\u003e\n\u003cp\u003eWhat sets the SRVL apart from the lead-acid Easy UPS On-Line SRV models in our catalogue is the battery: Schneider Electric prints an 8 to 10 year battery life for the lithium-ion pack, against three to five years for VRLA, and a 4.8 hours recharge. In a warm Singapore comms room that is the difference between one battery cycle and two or three over the life of the UPS.\u003c\/p\u003e\n\u003ch3\u003e0.9 Power Factor and 2700 W of Real Power\u003c\/h3\u003e\n\u003cp\u003eThe SRVL is a 0.9 power factor build, delivering 2700 W from 3000 VA. Watts are the number that decides whether a UPS copes with a rack of servers, switches and storage, so size on the total continuous watts of the connected load with headroom for start-up surge. Schneider Electric prints up to 90% efficiency in on-line double-conversion mode and up to 96% in ECO mode for this model, which keeps the heat load in the cabinet modest.\u003c\/p\u003e\n\u003cp\u003eOutput is provided on six IEC C13 outlets plus one IEC C19 outlet, so ordinary IEC leads plug straight in. The input is an IEC 60320 C20 inlet with a wide 160–300 V operating window at full load (110–300 V at 60% load).\u003c\/p\u003e\n\u003ch3\u003eRuntime, and Adding a Second Pack\u003c\/h3\u003e\n\u003cp\u003eSchneider Electric's SRVL brochure prints 85 minutes at half load and 40 minutes at full load for this model on its internal pack alone. Where you need longer, additional SRVL48RMBP2U packs can be added — Schneider's product page states up to two; confirm with us for your runtime target.\u003c\/p\u003e\n\u003ch3\u003e4U Rack\/Tower Convertible, Rails Included\u003c\/h3\u003e\n\u003cp\u003eThe kit occupies \u003cstrong\u003e4U\u003c\/strong\u003e: a 2U power module of 86 x 438 x 502 mm and a 2U battery pack of 86 x 438 x 616 mm, with two SRVRK1 rail kits in the carton and stabiliser brackets for tower use. At 616 mm deep the pack needs a server-depth cabinet rather than a shallow comms cabinet.\u003c\/p\u003e\n\u003ch3\u003eInput Lead — Read Before You Plug In\u003c\/h3\u003e\n\u003cp\u003eThe input lead in the carton is a \u003cstrong\u003eSchuko (CEE 7\/7) to IEC\u003c\/strong\u003e mains lead. A Schuko plug does not fit Singapore's BS 1363 (Type G) wall sockets. The normal solution in Singapore is a BS 1363 to IEC lead of the right rating, or feeding the UPS from an IEC-outlet rack PDU such as the \u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559 basic rack PDU\u003c\/a\u003e. We do not bundle a BS 1363 lead with the UPS, so tell us how you intend to feed it and we will quote the right lead.\u003c\/p\u003e\n\u003ch3\u003eEmergency Power Off, Intelligent Card Slot and PowerChute\u003c\/h3\u003e\n\u003cp\u003eThe power module carries a multifunction LCD, USB and RS-232 ports and an Emergency Power Off connector for a room EPO loop. An Intelligent Card Slot takes the optional AP9544 Network Management Card 3 for SNMP monitoring, with Modbus and dry-contact cards also listed by Schneider Electric. PowerChute software is in the box for graceful unattended shutdown over USB or serial.\u003c\/p\u003e\n\u003ch3\u003eSupplied Locally, with GST Invoice and Singapore Warranty\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the SRVL3KRILRK as an APC by Schneider Electric product with a full GST invoice and local Singapore warranty support. Schneider Electric's printed term for this model is three years repair or replace on the UPS and five years repair or replace on the lithium-ion battery.\u003c\/p\u003e\n\u003cp\u003eNot sure whether you need this kit or the lead-acid \u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-battery-pack-rail-kit-srv3krilrk-e\"\u003eSRV3KRILRK-E\u003c\/a\u003e? Email sales@sourceit.com.sg with your load and runtime and we will size it for you.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRVL3KRILRK Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line, 3kVA, Lithium-ion, Rack\/Tower 4U, 230V, 6 IEC C13 + 1 IEC C19 outlets, Intelligent Card Slot, Extended runtime, W\/ rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRVL3KRILRK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit Composition\u003c\/td\u003e\n\u003ctd\u003eSRVLPM3KRIL 2U power module x 1, SRVL48RMBP2U 2U lithium-ion battery pack x 1, SRVRK1 rail kit x 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line Lithium-ion SRVL, extended-runtime models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eRack\/Tower convertible, 4U in total (2U module + 2U battery pack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e3 years UPS, 5 years lithium-ion battery — repair or replace (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eIncluded with every unit supplied by SourceIT, together with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eOutput\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2700 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Factor\u003c\/td\u003e\n\u003ctd\u003e0.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V, configurable to 220 V \/ 230 V \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±3 Hz synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e6 x IEC C13 + 1 x IEC C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor\u003c\/td\u003e\n\u003ctd\u003e3:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 90% in on-line double-conversion mode; up to 96% in ECO mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bypass\u003c\/td\u003e\n\u003ctd\u003eAutomatic and manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Regulation\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric as a percentage figure for this model — ask us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric — the load is fed continuously from the inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInput\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (full load)\u003c\/td\u003e\n\u003ctd\u003e160–300 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (60% load)\u003c\/td\u003e\n\u003ctd\u003e110–300 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C20 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Lead Supplied\u003c\/td\u003e\n\u003ctd\u003eSchuko (CEE 7\/7) to IEC lead — does not fit Singapore BS 1363 sockets; see the note above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBatteries \u0026amp; Runtime\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLithium-ion, 8 to 10 year battery life as printed by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Pack\u003c\/td\u003e\n\u003ctd\u003eSRVL48RMBP2U — 48 V, 2400 Wh, 2U rackmount (recommended charge voltage 52.5 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Bus Voltage\u003c\/td\u003e\n\u003ctd\u003e48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e4.8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charger Power\u003c\/td\u003e\n\u003ctd\u003e500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Half Load\u003c\/td\u003e\n\u003ctd\u003e85 minutes — as published by Schneider Electric (brochure), internal pack only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Full Load\u003c\/td\u003e\n\u003ctd\u003e40 minutes — as published by Schneider Electric (brochure), internal pack only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Battery Packs\u003c\/td\u003e\n\u003ctd\u003eAdditional SRVL48RMBP2U packs can be added — Schneider's product page states up to two; confirm with us for your runtime target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Replacement\u003c\/td\u003e\n\u003ctd\u003eExternal 2U pack connected by cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCommunications \u0026amp; Management\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eUSB (Type B), RS-232 serial, EPO connector, RJ45 battery-pack communication port, Intelligent Card Slot (1 slot, free)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Panel\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Alarm\u003c\/td\u003e\n\u003ctd\u003eAlarm when on battery, distinctive low-battery alarm, overload continuous-tone alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eOptional AP9544 Network Management Card 3 for the Intelligent Card Slot; Modbus and dry-contact cards also listed by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutdown Software\u003c\/td\u003e\n\u003ctd\u003ePowerChute (supplied in the box) over USB or serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e4U (2U power module + 2U battery pack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, Kit (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e172 x 438 x 616 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, Power Module\u003c\/td\u003e\n\u003ctd\u003e86 x 438 x 502 mm, 10.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, Battery Pack\u003c\/td\u003e\n\u003ctd\u003e86 x 438 x 616 mm, 28.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (kit)\u003c\/td\u003e\n\u003ctd\u003e38.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight (kit)\u003c\/td\u003e\n\u003ctd\u003e50.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Carton\u003c\/td\u003e\n\u003ctd\u003e48 x 80 x 60 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Position\u003c\/td\u003e\n\u003ctd\u003eHorizontal (rack) and vertical (tower), rail kits and stabiliser brackets supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e50 dBA at 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e1024 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eBlack with silver front bezel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e0–40 °C at rated load (40–50 °C with load derated to 80%), 0–95% relative humidity non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003eNot printed as a single figure by Schneider Electric across its documents — ask us if your site is above 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Environment\u003c\/td\u003e\n\u003ctd\u003e−20 to 50 °C, 0–95% relative humidity non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications (as printed)\u003c\/td\u003e\n\u003ctd\u003eCB, CE, RCM, EAC, TISI, UKCA, KC, UN 38.3, IEC 62619\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eSee the In the Box list in the Package Contents section below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eOutlets and What Can Be Plugged In\u003c\/h3\u003e\n\u003cp\u003eThe SRVL3KRILRK provides \u003cstrong\u003e6 x IEC C13 + 1 x IEC C19\u003c\/strong\u003e on the output. Standard IEC leads plug straight in; an IEC C13 to C14 lead is in the box and locking lead kits such as the \u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAP8704S-WW\u003c\/a\u003e are available. The input is an IEC 60320 C20 inlet. Size on watts, not on VA: this is a 0.9 power factor build rated at 2700 W, so add up the continuous draw of everything you intend to connect with headroom for start-up surge.\u003c\/p\u003e\n\u003ch3\u003eRack Fit\u003c\/h3\u003e\n\u003cp\u003eThe kit occupies \u003cstrong\u003e4U\u003c\/strong\u003e. The power module is 86 x 438 x 502 mm and the battery pack 86 x 438 x 616 mm, so the pack needs at least 616 mm of usable depth plus cable clearance. Two SRVRK1 rail kits and stabiliser brackets are in the carton. If depth is tight, ask us about the 2U lead-acid rackmount models.\u003c\/p\u003e\n\u003ch3\u003eBattery and Runtime\u003c\/h3\u003e\n\u003cp\u003eThe battery is a 48 V, 2400 Wh lithium-ion pack (SRVL48RMBP2U) with an 8 to 10 year battery life as printed by Schneider Electric and a 4.8 hours recharge. Schneider's brochure prints 85 minutes at half load and 40 minutes at full load on the internal pack; treat those as sizing figures, since real runtime depends on load, pack age and temperature.\u003c\/p\u003e\n\u003cp\u003eAdditional SRVL48RMBP2U packs can be added — Schneider's product page states up to two; confirm with us for your runtime target. Each extra pack is another 2U and another 28.3 kg, and it is ordered without rails, so add an SRVRK1 rail kit for each one.\u003c\/p\u003e\n\u003ch3\u003eInput Lead\u003c\/h3\u003e\n\u003cp\u003eThe supplied input lead has a Schuko plug that does not fit Singapore BS 1363 sockets — see the note in the description above and tell us how you intend to feed the UPS.\u003c\/p\u003e\n\u003ch3\u003eManagement and Software\u003c\/h3\u003e\n\u003cp\u003eAn Intelligent Card Slot takes the optional AP9544 Network Management Card 3 for SNMP monitoring and alerting. PowerChute connects over the supplied USB or RS-232 cable for graceful unattended shutdown, and the EPO connector lets a room emergency stop drop the UPS output.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRVL Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cp\u003eUser manual and safety guide, PowerChute management software, RS-232 serial cable, USB cable, RJ45 cable, rack-mount brackets with 8 flat-head screws, stabiliser brackets with 4 pan-head screws, Schuko to IEC utility power cable, IEC C13 to C14 output cable, plus the SRVL48RMBP2U battery pack and its battery cable, and two SRVRK1 rail kits\u003c\/p\u003e\n\u003ch3\u003eEasy UPS On-Line Lithium-ion SRVL Range Ordering Information\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVL1KRILRK (ask us)\u003c\/td\u003e\n\u003ctd\u003e1 kVA \/ 900 W\u003c\/td\u003e\n\u003ctd\u003eRack\/Tower 4U, rails included\u003c\/td\u003e\n\u003ctd\u003e6 x IEC C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVL2KRILRK (ask us)\u003c\/td\u003e\n\u003ctd\u003e2 kVA \/ 1800 W\u003c\/td\u003e\n\u003ctd\u003eRack\/Tower 4U, rails included\u003c\/td\u003e\n\u003ctd\u003e6 x IEC C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSRVL3KRILRK (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kVA \/ 2700 W\u003c\/td\u003e\n\u003ctd\u003eRack\/Tower 4U, rails included\u003c\/td\u003e\n\u003ctd\u003e6 x IEC C13 + 1 x IEC C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVL6KRILRK (ask us)\u003c\/td\u003e\n\u003ctd\u003e6 kVA \/ 6 kW\u003c\/td\u003e\n\u003ctd\u003eRack\/Tower 5U, rails included\u003c\/td\u003e\n\u003ctd\u003eHardwire 1P+N+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVL48RMBP2U (ask us)\u003c\/td\u003e\n\u003ctd\u003e48 V, 2400 Wh battery pack\u003c\/td\u003e\n\u003ctd\u003e2U, rail kit SRVRK1 sold separately\u003c\/td\u003e\n\u003ctd\u003eFor the 1, 2 and 3 kVA kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9544\u003c\/td\u003e\n\u003ctd\u003eNetwork Management Card 3 for the Intelligent Card Slot — SNMP monitoring and alerting, ask us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVL48RMBP2U\u003c\/td\u003e\n\u003ctd\u003eAdditional 48 V, 2400 Wh lithium-ion battery pack, 2U — Schneider's product page states up to two additional packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVRK1\u003c\/td\u003e\n\u003ctd\u003eRail kit for one 2U unit, needed for each additional battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1U basic rack PDU with an IEC inlet — one way to feed the UPS without a Schuko lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eThe Lead-Acid Easy UPS On-Line SRV Kits\u003c\/h3\u003e\n\u003cp\u003eIf lithium-ion is more than the application justifies, the 0.9 power factor -E generation of the lead-acid extended-runtime kits covers the same ratings at 4U with a VRLA pack.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-battery-pack-rail-kit-srv1krilrk-e\"\u003eSRV1KRILRK-E\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kVA \/ 900 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 4U, VRLA pack, rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-battery-pack-rail-kit-srv2krilrk-e\"\u003eSRV2KRILRK-E\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kVA \/ 1800 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 4U, VRLA pack, rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-battery-pack-rail-kit-srv3krilrk-e\"\u003eSRV3KRILRK-E\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kVA \/ 2700 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 4U, VRLA pack, rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eSchneider Electric hosts the official documentation for this product. The links below are the Schneider Electric pages for this part number; each one names the correct model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric product page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/my\/en\/product\/SRVL3KRILRK\/apc-easy-ups-online-3kva-lithiumion-rack-tower-4u-230v-6-iec-c13-+-1-iec-c19-outlets-intelligent-card-slot-extended-runtime-w-rail-kit\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC SRVL3KRILRK on se.com\u003c\/a\u003e — Malaysia (English) site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser manual, Easy UPS On-Line SRVL 1000\/2000\/3000 VA extended runtime (SRVLPM1KRIL \/ SRVLPM2KRIL \/ SRVLPM3KRIL)\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/ie\/en\/download\/document\/SPD_EU_UM_TME23545_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider document SPD_EU_UM_TME23545_EN\u003c\/a\u003e — document landing page, Ireland (English) site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrochure, APC Easy UPS On-Line Lithium-Ion SRVL 230V Extended Runtime\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/uk\/en\/download\/document\/SPD_SRVL_230V_Brochure_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider document SPD_SRVL_230V_Brochure_EN\u003c\/a\u003e — document landing page, UK site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eSRVL3KRILRK\u003c\/strong\u003e and we will send you the current PDF datasheet and user manual directly.\u003c\/p\u003e\n\u003cp\u003eThe governing user manual for the power module is Schneider Electric document 990-91562, and the battery pack has its own user manual (Schneider reference SPD_EU_UM_TME21198_EN) which we can send on request.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRVL3KRILRK\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat is the difference between the VA and the watt rating, and how do I size this UPS?\u003c\/h3\u003e\n\u003cp\u003eVA is apparent power and watts is real power; the watt rating is what limits your load. The SRVL is a 0.9 power factor build, so this model gives 2700 W from 3000 VA. Total up the continuous watts of everything you want to protect, allow headroom for start-up surge and growth, and compare that to 2700 W.\u003c\/p\u003e\n\u003ch3\u003eWhat runtime will I get?\u003c\/h3\u003e\n\u003cp\u003eSchneider Electric's brochure prints 85 minutes at half load and 40 minutes at full load for this model on its internal SRVL48RMBP2U pack. Runtime falls sharply as load rises, so send us your load in watts and the hold-up time you need and we will size it against the manufacturer's runtime curve, including extra packs if you need them.\u003c\/p\u003e\n\u003ch3\u003eCan I add more battery packs, and how many?\u003c\/h3\u003e\n\u003cp\u003eYes. Additional SRVL48RMBP2U packs can be added — Schneider's product page states up to two; confirm with us for your runtime target. Each pack is 2U, 28.3 kg and 616 mm deep and ships without rails, so order an SRVRK1 rail kit for each one.\u003c\/p\u003e\n\u003ch3\u003eHow long does the lithium-ion battery last, and is it user replaceable?\u003c\/h3\u003e\n\u003cp\u003eSchneider Electric prints an 8 to 10 year battery life, two to three times what a VRLA battery gives in the same cabinet. The pack is a separate 2U unit connected by cable rather than a cartridge inside the UPS; Schneider Electric does not describe changing it with the load running, so plan a short maintenance window.\u003c\/p\u003e\n\u003ch3\u003eWill the supplied power lead work in Singapore?\u003c\/h3\u003e\n\u003cp\u003eNot directly. The input lead in the box is a Schuko (CEE 7\/7) to IEC lead, and a Schuko plug does not fit a Singapore BS 1363 (Type G) socket. Use a BS 1363 to IEC lead of the right rating, or feed the UPS from an IEC-outlet rack PDU. We do not bundle a BS 1363 lead, so tell us how you plan to feed the UPS and we will quote the correct lead.\u003c\/p\u003e\n\u003ch3\u003eHow much rack space does it need, and is a rail kit included?\u003c\/h3\u003e\n\u003cp\u003e4U: a 2U power module and a 2U battery pack, with two SRVRK1 rail kits in the carton. The pack is 616 mm deep, so it needs a server-depth cabinet.\u003c\/p\u003e\n\u003ch3\u003eHow do I monitor it and shut servers down safely?\u003c\/h3\u003e\n\u003cp\u003eThe Intelligent Card Slot takes the optional AP9544 Network Management Card 3 for SNMP monitoring; PowerChute is in the box for shutdown over USB or RS-232, and an EPO connector is fitted.\u003c\/p\u003e\n\u003ch3\u003eHow does this compare with the lead-acid SRV -E extended-runtime kits?\u003c\/h3\u003e\n\u003cp\u003eThe lead-acid \u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-battery-pack-rail-kit-srv3krilrk-e\"\u003eSRV3KRILRK-E\u003c\/a\u003e gives the same 2700 W at 4U with a VRLA pack, a two-year warranty and a three to five year battery cycle. The lithium-ion SRVL carries a three-year UPS and five-year battery warranty, an 8 to 10 year battery life and a faster recharge.\u003c\/p\u003e\n\u003ch3\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC SRVL3KRILRK sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs the SRVL3KRILRK with a three-year manufacturer warranty on the UPS and a five-year manufacturer warranty on the lithium-ion battery.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482412941476,"sku":"SRVL3KRILRK","price":3647.8,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_eb7d0cb6-f7e5-4dde-8616-3fe7267ca042.png?v=1789701502","url":"https:\/\/sourceit.com.sg\/products\/apc-easy-ups-on-line-li-ion-srvl-3000va-2700w-rack-tower-4u-230v-extended-runtime-rail-kit-srvl3krilrk","provider":"SourceIT ","version":"1.0","type":"link"}