{"product_id":"apc-easy-rack-pdu-metered-0u-1-phase-3-7kw-230v-16a-18-c13-3-c19-iec-60309-epdu1116m","title":"APC Easy Rack PDU Metered 0U 16A 230V 3.7kW 18 C13 3 C19 IEC 309 Inlet","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Easy Rack PDU, Metered, 0U, 1 Phase, 3.7kW 230V 16A, 18 C13 \u0026amp; 3 C19 Outlets, IEC 60309 2P+E Inlet (EPDU1116M) - 1 Year Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eMetered 0U Distribution at a Value Price\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC Easy Rack PDU Metered EPDU1116M puts a metered, network-managed 0U strip within reach of a branch office or small server room budget. Eighteen IEC C13 and three IEC C19 outlets on a 902 mm vertical strip, rated 16 A and 3.7 kW at 230 V, fed by a 3 m cord ending in an IEC 60309 16 A 2P+E commando plug. Schneider's own description is \"reliable and affordable rack power distribution\", and that is exactly the brief.\u003c\/p\u003e\n\u003cp\u003eThe Easy Rack PDU line sits below the NetShelter 2G and 9000 series: the same job of metered distribution, a simpler feature set, and a one-year warranty rather than two.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLocal LCD and Load LED, Remote Web and SNMP\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA local LCD shows the current draw at the strip and a load-indicator LED gives a glance-level status, so an engineer at the rack can see the headroom without a laptop. Remotely, the strip serves a web interface, speaks SNMP v1, v2c and v3 and Modbus TCP, and lets you set alarm thresholds so an overload is warned about before it trips anything. Management is built in: a web interface over HTTP or HTTPS, SNMP v1, v2c and v3 with traps, and Modbus TCP, reporting current, power and voltage. There is a port for a temperature and humidity sensor and the firmware is flash-upgradeable. Toolless vertical mounting brackets are supplied.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e16 A and 3.7 kW Through a Commando Plug\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 16 A rating covers a cabinet of network equipment and a handful of servers; for a rack of dual-PSU servers you would run two strips on A and B feeds or step up to the 32 A EPDU1132M. The commando plug means the rack needs a 16 A IEC 60309 socket - the standard arrangement in a Singapore data centre or a properly wired comms room, but not something a wall socket provides.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eA Half-Height Strip for Mid-Height and Full-Height Cabinets\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAt 902 mm long, 62 mm wide and 44 mm deep and 2.5 kg, the EPDU1116M fits a 24U or 27U enclosure with a vertical channel and takes up about half the channel in a 42U rack, leaving space for a second strip. Its aluminium housing keeps the weight down.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC EPDU1116M Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy Rack PDU, Metered, 0U, 1 Phase, 3.7kW, 230V, 16A, 18 x C13 and 3 x C19 outlets, IEC60309 2P+E inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eEPDU1116M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAPC Easy Rack PDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMetered Rack Power Distribution Unit (PDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eZero U (0U), vertical side mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e1-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 16 A 2P+E plug on attached cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e200 V, 208 V, 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacity\u003c\/td\u003e\n\u003ctd\u003e3,680 VA (3.7 kW at 230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eEighteen (18) IEC 60320 C13 and three (3) IEC 60320 C19 - 21 outlets total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Total Current Draw\u003c\/td\u003e\n\u003ctd\u003e16 A across the whole strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMetering, Switching \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eDevice level - current, power and voltage for the whole strip. Not metered per outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Display\u003c\/td\u003e\n\u003ctd\u003eLCD for local current monitoring, plus load indicator LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd\u003eNot fitted - this is a Metered model, not a Switched one\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eBuilt in - no separate card required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interfaces\u003c\/td\u003e\n\u003ctd\u003eWeb (HTTP\/HTTPS), SNMP v1, v2c, v3 with traps, Modbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Sensor Port\u003c\/td\u003e\n\u003ctd\u003eTemperature\/humidity sensor port - sensor sold separately, ask us for the matching part\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware\u003c\/td\u003e\n\u003ctd\u003eFlash upgradeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided - APC Rack PDUs are distribution devices, not surge suppressors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e902 x 62 x 44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eAluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eToolless vertical mounting; mounting brackets included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 15,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, TÜV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eEU RoHS compliant; mercury free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Rack Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Eighteen IEC C13 outlets for C14-corded servers, switches, firewalls and appliances, and three IEC C19 outlets for C20-corded storage, a larger switch or a rack UPS input. Twenty-one outlets is plenty for a mid-height cabinet or one feed of a full-height rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoad planning.\u003c\/strong\u003e 16 A total, 3,680 VA at 230 V. The LCD and the web interface both show the aggregate load, and the alarm threshold warns you as you approach the limit. Plan against total nameplate current, not outlet count. For a heavier rack, the 32 A EPDU1132M carries twice the load on the same platform.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeeding it.\u003c\/strong\u003e The attached 3 m cord ends in an IEC 60309 16 A 2P+E commando plug, so the rack needs a matching 16 A socket on a row PDU, busway or fixed outlet. It cannot be plugged into a BS 1363 wall socket or a C13 UPS outlet. If your supply is a C19 outlet on a UPS, the \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e with its C20 inlet is the strip to use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e A 0U strip 902 mm long, 62 mm wide and 44 mm deep, weighing 2.5 kg. It fits a 24U or 27U enclosure with a vertical channel and takes about half the channel in a 42U rack, mounted toolless with the supplied brackets. Note the 62 mm width - a little wider than the 56 mm NetShelter strips - and check the channel clearance in a narrow cabinet. For a wallmount or short cabinet, the 1U \u003ca href=\"\/products\/apc-easy-rack-pdu-basic-1u-1-phase-2-3kw-230v-epdu1010b-sch\"\u003eEPDU1010B-SCH\u003c\/a\u003e is the Easy Rack PDU alternative.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManagement and sensors.\u003c\/strong\u003e Web, SNMP v1\/v2c\/v3 and Modbus TCP are built in, with a port for a temperature and humidity sensor. Ask us to confirm the matching sensor part for the Easy Rack PDU line when you order - the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH\u003c\/a\u003e is the NetShelter sensor and we will check which one this range takes. The AP9640 and AP9641 cards we sell are Smart-UPS accessories and are not used with this PDU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it does not do.\u003c\/strong\u003e No outlet switching - to power-cycle a device remotely you want the switched \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e in 1U or the 0U APDU9959EU3. No per-outlet metering. And no surge protection, which belongs at a UPS upstream.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy Rack PDU Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC Easy Rack PDU Metered (EPDU1116M) with attached 3 m IEC 60309 16 A input cord\u003c\/li\u003e\n\u003cli\u003eVertical mounting brackets\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEasy Rack PDU \u0026amp; Metered Rack PDU Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-rack-pdu-basic-1u-1-phase-2-3kw-230v-epdu1010b-sch\"\u003eEPDU1010B-SCH\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic (Easy Rack PDU)\u003c\/td\u003e\n\u003ctd\u003e230 V, 10 A, 2.3 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C14 inlet, 2.5 m cord\u003c\/td\u003e\n\u003ctd\u003e(6) SCHUKO, (1) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEPDU1116M (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMetered (Easy Rack PDU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 16 A, 3.7 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 60309 16 A cord, 3 m\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(18) C13, (3) C19\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0U, 902 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPDU1132M\u003c\/td\u003e\n\u003ctd\u003eMetered (Easy Rack PDU)\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 32 A cord, 3 m\u003c\/td\u003e\n\u003ctd\u003e(20) C13, (4) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,175 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-rack-pdu-switched-0u-3-phase-22kw-230v-epdu1232s\"\u003eEPDU1232S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched (Easy Rack PDU)\u003c\/td\u003e\n\u003ctd\u003e230 V, 3-phase, 22 kW\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 3P+N+E\u003c\/td\u003e\n\u003ctd\u003eSee listing\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered (NetShelter 2G)\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, no cord\u003c\/td\u003e\n\u003ctd\u003e(18) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 902 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8858EU3\u003c\/td\u003e\n\u003ctd\u003eMetered (NetShelter 2G)\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003e3 m locking cord, IEC 60309 16 A plug\u003c\/td\u003e\n\u003ctd\u003e(18) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 902 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-metered-2u-32a-230v-12-c13-4-c19\"\u003eAP7822B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered (NetShelter)\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(12) C13, (4) C19\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered (NetShelter 2G)\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(36) C13, (6) C19\u003c\/td\u003e\n\u003ctd\u003e0U, 1,791 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC EPDU1116M. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/EPDU1116M\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric EPDU1116M product page (Singapore)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/ie\/en\/download\/document\/Easy_Metered_PDU_USR_Guide_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Easy Rack PDU Metered (EPDU1016M, EPDU1116M, EPDU1132M) - User Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's own datasheet download links redirect to a host that has served wrong-model files, so email sales@sourceit.com.sg quoting the SKU for the PDF and we will send you the correct document.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC EPDU1116M\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the difference between an Easy Rack PDU and a NetShelter Rack PDU?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Easy Rack PDU line is Schneider's value range: the same metered distribution job, a simpler management feature set - web, SNMP and Modbus TCP rather than the NetShelter's SSH, Telnet, Secure NMC subscription and EcoStruxure IT integration - and a one-year warranty instead of two. For a branch cabinet or a small server room the EPDU1116M does everything you need; for a colocation or managed environment the AP8858EU3 is the NetShelter equivalent.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs it metered per outlet?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. The EPDU1116M meters at device level - current, power and voltage for the whole strip - on the LCD and over the network. Per-outlet metering is a NetShelter 2G feature, on the AP8659.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat supply does it need?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA 16 A IEC 60309 2P+E commando socket. The 3 m cord is attached, so nothing to buy, but a wall socket or a C13 UPS outlet will not do - if that is what you have, the \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e with its C20 inlet is the right strip.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan I add a temperature and humidity sensor?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes, the strip has a temperature\/humidity sensor port. Ask us to confirm the matching sensor part number for the Easy Rack PDU line when you order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider states that APC Rack PDUs are power distribution devices without built-in surge suppression. Feed the strip from a UPS if the load needs protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan it switch outlets off remotely?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo - Metered means measurement, not control. The Easy Rack PDU line has switched models such as the three-phase \u003ca href=\"\/products\/apc-easy-rack-pdu-switched-0u-3-phase-22kw-230v-epdu1232s\"\u003eEPDU1232S\u003c\/a\u003e, and in the NetShelter range the 1U \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e and the 0U APDU9959EU3 provide per-outlet switching.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does it compare with the EPDU1132M?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSame platform, twice the capacity. The EPDU1132M is 32 A and 7.4 kW with twenty C13 and four C19 outlets on a 1,175 mm strip and an IEC 60309 32 A plug; this EPDU1116M is 16 A and 3.7 kW with eighteen C13 and three C19 on a 902 mm strip and a 16 A plug. Choose on the socket in the rack and the load.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC Easy Rack PDU Metered EPDU1116M sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs the EPDU1116M with a 1-year manufacturer warranty.\u003c\/p\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482588938404,"sku":"EPDU1116M","price":501.4,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_45051881-8ca9-416d-a05a-5f1734205695.jpg?v=1789712566","url":"https:\/\/sourceit.com.sg\/products\/apc-easy-rack-pdu-metered-0u-1-phase-3-7kw-230v-16a-18-c13-3-c19-iec-60309-epdu1116m","provider":"SourceIT ","version":"1.0","type":"link"}