{"product_id":"apc-easy-rack-42u-800mm-wide-1000mm-deep-server-rack-enclosure-black-er8202","title":"APC Easy Rack 42U 800mm Wide 1000mm Deep Server Rack Enclosure Black","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Easy Rack, 42U, Black, With Roof, Castors, Feet, 4 Brackets, and Side Panels, No Bottom, 1991H x 800W x 1000D mm (ER8202) - 5 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eAPC ER8202 — a 42U, 800 mm wide, 1000 mm deep server cabinet that arrives assembled\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC ER8202 is the Easy Rack 800mm\/42U\/1000mm from the Easy Rack range by APC by Schneider Electric: a 42U floor-standing enclosure, 1991 mm high, 800 mm wide and 1000 mm deep, delivered assembled with the roof, both side panels, four castors, four levelling feet and four baying brackets already on it. Wheel it off the pallet, roll it to the comms room, drop the feet and start racking. There is no bottom panel, which is deliberate — it is what lets you bring power and data up from a raised floor or a floor trunking without cutting anything.\u003c\/p\u003e\n\u003cp\u003eEasy Rack is Schneider's value line, sitting below the NetShelter SX in the catalogue. It keeps the things that matter on a working cabinet — an EIA-310-E compliant 19-inch frame, a 1200 kg static rating, ventilated doors, keyed-alike locking — and leaves out the premium extras. For a Singapore SME server room, a branch comms room or a small colocation footprint, that is usually the right trade.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e800 mm wide, 1000 mm deep: what that buys you\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 800 mm width is the reason to choose the ER8202 over a 600 mm cabinet. The extra 200 mm sits either side of the 19-inch mounting rails, and that is exactly where you want space for vertical cable managers, 0U rack PDUs and the bundles of patch leads that a 42U rack full of switches and patch panels generates. If this cabinet is going to carry structured cabling or a core switch with hundreds of ports, take the 800 mm.\u003c\/p\u003e\n\u003cp\u003eThe 1000 mm external depth gives a mounting-rail adjustment range of 242 mm to 838 mm between the front and rear rails, with the rails factory-set at 737 mm — the position Schneider specifies for standard rack-mount servers and UPS. That accommodates today's 1U and 2U servers, rack-mount Smart-UPS and Easy UPS units and their battery packs with room behind for power cords and PDUs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eVentilated doors, locking side panels and a 1200 kg frame\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFront and rear doors are perforated with 80.8% open area — the figure Schneider prints in the Easy Rack installation guide — so front-to-back airflow through the cabinet is close to that of an open frame. The front door is removable and reversible, so the hinge and lock can be swapped to the opposite side to suit the room. Doors and side panels are keyed alike and the keys are in the box. The side panels are split into an upper locking panel and a lower panel that can only be removed once the upper one is off, so a technician can get at one half of the cabinet without lifting a full-height sheet of steel.\u003c\/p\u003e\n\u003cp\u003eThe frame is rated for 1200 kg static and 600 kg dynamic (rolling on the castors), with 16-gauge posts, an 18-gauge front door and a 19-gauge rear door. In practice that means a cabinet full of 2U servers, a 3 kVA rack UPS and its battery packs is well inside the limit — but Schneider is explicit that the castors are for positioning only, and that the cabinet should be levelled on its feet and secured to the floor before equipment goes in.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSingapore installation notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNet weight is 128.4 kg and it ships on a pallet at 137 kg, 1050 mm wide by 850 mm long by 2120 mm high, so plan the delivery route: a goods lift, a ramp, and a doorway taller than 2.12 m for the crate, or unpack at the loading bay and roll the bare cabinet (1991 mm high) through a standard door. The cabinet has two M6 earthing inserts top and bottom for bonding to the building earth, which Schneider requires. Everything SourceIT ships is local Singapore stock with a GST invoice and a local 5-year Schneider warranty behind it.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC ER8202 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eFigures below are taken from the Schneider Electric product page and the APC ER8202 product data sheet as carried by two independent distributor mirrors that agree, and from the Easy Rack installation guide. Where Schneider does not publish a value for this exact part number, the row is left out rather than filled in from a similar model.\u003c\/p\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eER8202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy Rack, 42U, Black, With Roof, Castors, Feet, 4 Brackets, and Side Panels, No Bottom, 1991H x 800W x 1000D mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAPC Easy Rack (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFloor-standing 19-inch server and network rack enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelivered\u003c\/td\u003e\n\u003ctd\u003eAssembled — roof, side panels, castors, levelling feet and 4 baying brackets fitted at the factory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003e5 years repair or replace, as printed on the Schneider data sheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupported locally by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDimensions \u0026amp; Capacity\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e42U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e1991 mm x 800 mm x 1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Width\u003c\/td\u003e\n\u003ctd\u003e19 inch (EIA-310-E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Rail Depth Range\u003c\/td\u003e\n\u003ctd\u003e242 mm minimum to 838 mm maximum (front rail to rear rail), factory set at 737 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Static Load\u003c\/td\u003e\n\u003ctd\u003e1200 kg (Schneider prints 1199.75 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Dynamic (Rolling) Load\u003c\/td\u003e\n\u003ctd\u003e600 kg (Schneider prints 599.65 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e128.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eConstruction \u0026amp; Access\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Door\u003c\/td\u003e\n\u003ctd\u003ePerforated, 80.8% open area, 18 gauge, removable and reversible, keyed lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Door\u003c\/td\u003e\n\u003ctd\u003ePerforated, 80.8% open area, 19 gauge, keyed lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVertical Posts\u003c\/td\u003e\n\u003ctd\u003e16 gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide Panels\u003c\/td\u003e\n\u003ctd\u003eIncluded; split into a removable locking upper panel and a removable lower panel on each side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoof\u003c\/td\u003e\n\u003ctd\u003eIncluded; removable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBottom\u003c\/td\u003e\n\u003ctd\u003eNo bottom panel — open for under-floor cable entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocks\u003c\/td\u003e\n\u003ctd\u003eDoors and side panels keyed alike; keys supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCastors\u003c\/td\u003e\n\u003ctd\u003e4, pre-installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLevelling Feet\u003c\/td\u003e\n\u003ctd\u003e4, supplied; lowered with a 13 mm open-ended spanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaying\u003c\/td\u003e\n\u003ctd\u003e4 brackets supplied (2 front, 2 rear) with M5 x 12 countersunk screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eAirflow \u0026amp; Cable Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor Perforation\u003c\/td\u003e\n\u003ctd\u003e80.8% open area front and rear for front-to-back airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Entry\u003c\/td\u003e\n\u003ctd\u003eOpen bottom for raised-floor or trunking entry; roof removable for overhead entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Mounting\u003c\/td\u003e\n\u003ctd\u003e0U rack PDUs and vertical cable managers fit inside the frame beside the rails; optional ER7PDUBRKT PDU brackets, ER7RCC42 rear cable channel and ER7VCM42 vertical cable manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Bag\u003c\/td\u003e\n\u003ctd\u003e50 x M6 cage nuts, 50 x M6 x 16 screws, 50 x plastic cup washers, 4 x M5 x 12 screws, Torx T30 \/ #2 Phillips tool, cage nut tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarthing\u003c\/td\u003e\n\u003ctd\u003eTwo M6 threaded inserts at the top and at the bottom of the frame for bonding to the building earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e42U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions (W x L x H)\u003c\/td\u003e\n\u003ctd\u003e1050 mm x 850 mm x 2120 mm, on pallet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e137 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEIA-310-E, UL 2416, UL 60950-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eEU RoHS: out of legal scope for this product category; packaging uses recycled cardboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat fits in the frame\u003c\/h4\u003e\n\u003cp\u003eAny EIA-310 19-inch equipment: rack-mount servers, switches, patch panels, NAS, KVM and the rack-mount Smart-UPS and Easy UPS models SourceIT sells. The front and rear rails are square-hole, so cage nuts (50 in the box) and toolless rails both work. The rail-to-rail range of 242 mm to 838 mm covers everything from a shallow patch panel to a full-depth server with rail kit; set the rails once for your deepest chassis and leave them.\u003c\/p\u003e\n\u003ch4\u003eUPS and rack PDU pairing\u003c\/h4\u003e\n\u003cp\u003eA 42U cabinet in a Singapore server room is normally fed from one or two rack PDUs and a rack-mount UPS at the bottom. For a single-phase 16 A feed the \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552 Rack PDU Basic 0U 16 A\u003c\/a\u003e or the \u003ca href=\"\/products\/apc-easy-rack-pdu-basic-1u-1-phase-2-3kw-230v-epdu1010b-sch\"\u003eEPDU1010B-SCH Easy Rack PDU Basic 1U\u003c\/a\u003e mount vertically in the rear corners without using a U; the \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-32a-230v-ap7553\"\u003eAP7553 Rack PDU Basic 0U 32 A\u003c\/a\u003e gives you a 32 A feed for a fuller rack. If you need per-outlet control the \u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B NetShelter Switched Rack PDU\u003c\/a\u003e is the usual choice, and the \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853 NetShelter Metered Rack PDU\u003c\/a\u003e or \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858 NetShelter Metered Rack PDU\u003c\/a\u003e give metering. Where two supplies are available, a rack ATS such as the \u003ca href=\"\/products\/apc-rack-ats-230v-10a-c14-in-12-c13-out\"\u003eAP4421 Rack ATS 10 A\u003c\/a\u003e or the \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423 Rack ATS 16 A\u003c\/a\u003e at the top of the rack keeps single-corded switches alive when one feed drops. For the UPS itself, the \u003ca href=\"\/products\/apc-smart-ups-1500va-lcd-rm-2u-230v-with-smartconnect-smt1500rmi2uc\"\u003eSmart-UPS SMT1500RMI2UC\u003c\/a\u003e in 2U or the \u003ca href=\"\/products\/apc-smart-ups-on-line-3kva-rackmount-2u-230v-8x-c13-2x-c19-iec-srt3000rmxli\"\u003eSmart-UPS SRT3000RMXLI\u003c\/a\u003e in 2U on-line double conversion are the common pairings for a cabinet this size, with the \u003ca href=\"\/products\/apc-smart-ups-rt-5kva-5kw-rack-tower-4u-230v-on-line-srtg5kxli\"\u003eSmart-UPS RT SRTG5KXLI\u003c\/a\u003e where the load approaches 5 kVA.\u003c\/p\u003e\n\u003ch4\u003eMonitoring\u003c\/h4\u003e\n\u003cp\u003eFit a \u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNetBotz Rack Monitor 250 (NBRK0250A)\u003c\/a\u003e for temperature, humidity, door and leak sensing across the cabinet, or if the UPS has a SmartSlot, an \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641 Network Management Card\u003c\/a\u003e with an \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH temperature and humidity sensor\u003c\/a\u003e at the top of the rack is the lower-cost way to catch a failed air-conditioner over a weekend.\u003c\/p\u003e\n\u003ch4\u003eRoom and floor\u003c\/h4\u003e\n\u003cp\u003eAllow clearance front and rear for the doors to swing and for a technician to work; Schneider's guidance for its cabinets is to keep the rear clear enough to open the door fully. The cabinet must be levelled on its feet and secured to the floor before it is loaded — the pallet shipping brackets can be reused as floor brackets. Baying two or more Easy Racks with the supplied brackets aligns them but Schneider states it gives only limited stability, so each cabinet still needs to be bolted down.\u003c\/p\u003e\n\u003ch4\u003eChoosing between the Easy Rack sizes\u003c\/h4\u003e\n\u003cp\u003eAll three Easy Rack 42U cabinets at SourceIT share the same frame, doors, load rating and warranty. Choose ER6202 for a standard 600 x 1000 mm server rack, ER6212 when you need 100 mm more depth for long chassis or rear PDUs, and ER8202 when the rack is a patching hub that needs 800 mm of width for vertical cable management.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; APC Easy Rack Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cp\u003eOne assembled Easy Rack 800mm\/42U\/1000mm cabinet with roof, two split side panels (upper locking and lower), front and rear perforated doors, 4 pre-installed castors, 4 levelling feet, 4 baying brackets, keys, and a hardware bag with 50 M6 cage nuts, 50 M6 x 16 screws, 50 plastic cup washers, 4 M5 x 12 screws, a Torx T30 \/ #2 Phillips tool and a cage nut tool. Shipped on a pallet with shipping brackets that can be reused to bolt the cabinet to the floor.\u003c\/p\u003e\n\u003ch4\u003eAPC Easy Rack 42U enclosures — the range at SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eER6202\u003c\/td\u003e\n\u003ctd\u003eEasy Rack 600 mm W x 1000 mm D, 42U, assembled — 1200 kg static, 100.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eER6212\u003c\/td\u003e\n\u003ctd\u003eEasy Rack 600 mm W x 1100 mm D, 42U, assembled — 1200 kg static, 105.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eER8202 (this listing)\u003c\/td\u003e\n\u003ctd\u003eEasy Rack 800 mm W x 1000 mm D, 42U, assembled — 1200 kg static, 128.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAR3100\u003c\/td\u003e\n\u003ctd\u003eNetShelter SX 600 mm W x 1070 mm D, 42U — the premium alternative with split rear doors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAR3340\u003c\/td\u003e\n\u003ctd\u003eNetShelter SX 750 mm W x 1200 mm D, 42U networking enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-6u-low-profile-wallmount-rack-enclosure-ar106vi\"\u003eAR106VI NetShelter 6U wall-mount enclosure\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNetShelter 6U wall-mount enclosure for a branch or small comms cupboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eRack power and monitoring to go with it\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552 Rack PDU Basic 0U 16 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU Basic 0U, 16 A, 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-32a-230v-ap7553\"\u003eAP7553 Rack PDU Basic 0U 32 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU Basic 0U, 32 A, 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559 Rack PDU Basic 1U 16 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU Basic 1U, 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-rack-pdu-basic-1u-1-phase-2-3kw-230v-epdu1010b-sch\"\u003eEPDU1010B-SCH Easy Rack PDU Basic 1U\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy Rack PDU Basic 1U, 2.3 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-rack-pdu-switched-0u-3-phase-22kw-230v-epdu1232s\"\u003eEPDU1232S Easy Rack PDU Switched 0U\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy Rack PDU Switched 0U, 3-phase 22 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B NetShelter Switched Rack PDU\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched Rack PDU, 1U, 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853 NetShelter Metered Rack PDU\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered Rack PDU, 0U, 32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423 Rack ATS 16 A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack ATS, 16 A, C20 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNetBotz Rack Monitor 250 (NBRK0250A)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNetBotz Rack Monitor 250, 1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eEasy Rack accessories not listed here — ER7BP1U blanking panels, ER7RCC42 rear cable channel, ER7VCM42 vertical cable manager, ER7PDUBRKT PDU brackets — are available to order; tell us the configuration and we will quote the set.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eLinks open on Schneider Electric's own site. Each one was checked before publication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/ER8202\/apc-easy-rack-42u-black-with-roof-castors-feet-4-brackets-and-side-panels-no-bottom-1991h-x-800w-x-1000d-mm\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for the APC ER8202 (United Kingdom site) — official product name, characteristics and the full document list\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's own datasheet download links redirect to a host that has served wrong-model files, so for the PDF datasheet or manual as a file for a tender, email sales@sourceit.com.sg quoting the SKU and we will send the correct document.\u003c\/p\u003e\n\u003cp\u003eNeed a compliance declaration, a CAD file or a written quotation for a tender? Contact SourceIT and we will supply it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC ER8202\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eDoes the ER8202 come assembled or flat packed?\u003c\/h4\u003e\n\u003cp\u003eAssembled. The ER-series part numbers without an FP suffix ship as a built cabinet on a pallet with the roof, side panels, doors, castors, feet and baying brackets already fitted. Schneider sells a separate flat-pack version of some sizes under an FP1 suffix for sites where the crate cannot get in; if your delivery route needs that, tell us before you order.\u003c\/p\u003e\n\u003ch4\u003eHow much can it carry?\u003c\/h4\u003e\n\u003cp\u003e1200 kg static once it is levelled on its feet and bolted down, and 600 kg dynamic when it is rolled on the castors. A typical mixed rack of servers, switches and a 3 kVA rack UPS with two battery packs sits comfortably under 500 kg, so the limit is rarely the constraint — the floor loading and the lift are more often the question.\u003c\/p\u003e\n\u003ch4\u003eAre the doors perforated, and can I reverse the front door?\u003c\/h4\u003e\n\u003cp\u003eYes on both. Front and rear doors have 80.8% open area for front-to-back airflow, and the front door is removable and reversible so the hinge and lock can be moved to the other side. Doors and side panels are keyed alike.\u003c\/p\u003e\n\u003ch4\u003eWhat is the usable depth between the rails?\u003c\/h4\u003e\n\u003cp\u003eThe front and rear mounting rails adjust from 242 mm to 838 mm apart, and are factory-set at 737 mm, which is the depth Schneider specifies for standard rack-mount servers and UPS. The external depth is 1000 mm, so there is room behind the rear rail for 0U PDUs and power leads.\u003c\/p\u003e\n\u003ch4\u003eIs there a bottom panel or cable entry?\u003c\/h4\u003e\n\u003cp\u003eThere is no bottom panel — the base is open, which is the usual arrangement for raised-floor rooms and for bringing cables up from floor trunking. For overhead entry the roof is removable. Brush-strip gland plates are not part of this part number.\u003c\/p\u003e\n\u003ch4\u003eWhich rack PDUs and UPS fit?\u003c\/h4\u003e\n\u003cp\u003eAny 19-inch EIA-310 equipment. 0U rack PDUs such as the \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552 Rack PDU Basic 0U 16 A\u003c\/a\u003e or \u003ca href=\"\/products\/apc-easy-rack-pdu-switched-0u-3-phase-22kw-230v-epdu1232s\"\u003eEPDU1232S Easy Rack PDU Switched 0U\u003c\/a\u003e mount vertically inside the frame, and 1U or 2U PDUs, ATS and rack-mount Smart-UPS units go on the rails. See the Compatibility accordion for the pairings we sell most often.\u003c\/p\u003e\n\u003ch4\u003eHow does the ER8202 differ from a NetShelter SX?\u003c\/h4\u003e\n\u003cp\u003eEasy Rack is the value line: same EIA-310-E frame, ventilated doors and locking, single-piece rear door, 1200 kg static rating. NetShelter SX adds split rear doors, a higher static rating, quick-release panels and a wider range of factory-fitted options. If the cabinet is a standard server or network rack for an office, the Easy Rack does the job; if you need the SX features, we stock AR3100 and AR3340 too.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC ER8202 sold by SourceIT comes with local Singapore warranty support and a GST invoice; APC by Schneider Electric prints a 5-year repair-or-replace factory warranty for the Easy Rack, which is the term we pass on.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482611482788,"sku":"ER8202","price":1913.6,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_9e1c59ba-27c8-4d84-8493-9bb5aa726787.png?v=1789715996","url":"https:\/\/sourceit.com.sg\/products\/apc-easy-rack-42u-800mm-wide-1000mm-deep-server-rack-enclosure-black-er8202","provider":"SourceIT ","version":"1.0","type":"link"}