{"product_id":"apc-dry-contact-i-o-accessory-for-nmc-universal-i-o-port-ap9810","title":"APC Dry Contact I\/O Accessory, 2 Inputs and Relay Output for NMC Ports","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Dry Contact I\/O Accessory, 2 Inputs \u0026amp; 1 Relay Output for Universal I\/O Port (AP9810) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eTwo Dry Contact Inputs and a Relay Output From a Sensor Port\u003c\/h3\u003e\n\u003cp\u003eThe APC Dry Contact I\/O Accessory (AP9810) is a small interface module that plugs into a universal I\/O port on an APC Network Management Card or Dry Contact I\/O Card and gives it hard-wired signalling: two dry contact inputs (Zone A and Zone B), one Form C relay output, and a 12 V, 25 mA supply for powering a small external sensor. It turns a management card that only spoke SNMP and e-mail into one that can also read a door switch or a leak detector and close a contact for an alarm panel.\u003c\/p\u003e\n\u003ch3\u003eWhere It Fits\u003c\/h3\u003e\n\u003cp\u003eSchneider designed the AP9810 for the universal I\/O ports found on the AP9641 Network Management Card 3 with environmental monitoring, the earlier AP9631 and AP9635 Network Management Card 2 models, and the AP9613 Dry Contact I\/O SmartSlot Card. On the AP9613 it lifts the card's contact count from four inputs and six outputs to eight of each. Because the accessory sits on a network-connected card, its inputs and relay are monitored and controlled from that card's web interface, and state changes on the inputs can be mapped to configurable actions such as an e-mail, an SNMP trap or a UPS shutdown.\u003c\/p\u003e\n\u003ch3\u003ePractical Uses in a Singapore Server Room\u003c\/h3\u003e\n\u003cp\u003ePlenty of comms rooms already have volt-free signals that nobody is watching: a fire-suppression pre-alarm, a water leak rope under the raised floor, a cabinet door contact, a generator-running signal. Wire two of them to the AP9810's inputs and the UPS management card reports them. The relay output goes the other way - a UPS-on-battery or low-runtime condition can drive a beacon, a BMS digital input or an annunciator panel that has never heard of SNMP.\u003c\/p\u003e\n\u003ch3\u003eSupplied Locally in Singapore with GST Invoice\u003c\/h3\u003e\n\u003cp\u003eThe AP9810 is available to order through SourceIT with local Singapore warranty support and a GST invoice. It ships with the network cable it needs, and installation is a plug-in job on the host card's universal I\/O port with screw terminals for your contacts.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP9810 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP9810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eDry Contact I\/O Accessory - additional dry contact input and relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAPC Management Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eAdds dry contact inputs and a relay output to a host with a universal I\/O port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eYes - supplied and supported locally by SourceIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eFunction \u0026amp; Connectivity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDry Contact Inputs\u003c\/td\u003e\n\u003ctd\u003e2 (Zone A and Zone B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output\u003c\/td\u003e\n\u003ctd\u003e1 x Form C relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Power Output\u003c\/td\u003e\n\u003ctd\u003e12 V DC, 25 mA (Pwr terminal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay - Normal Switching Capacity\u003c\/td\u003e\n\u003ctd\u003e1 A at 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay - Maximum Switching Power\u003c\/td\u003e\n\u003ctd\u003e30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay - Maximum Switching Voltage\u003c\/td\u003e\n\u003ctd\u003e60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay - Maximum Switching and Carrying Current\u003c\/td\u003e\n\u003ctd\u003e2 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay - Surge Rating\u003c\/td\u003e\n\u003ctd\u003e2 kV per Bellcore TA-NWT-001089; 1.5 kV per FCC Part 68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply From Host\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Connection\u003c\/td\u003e\n\u003ctd\u003eUniversal I\/O port via the supplied network cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Hosts\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641\u003c\/a\u003e NMC3 with environmental monitoring; AP9631 and AP9635 NMC2; \u003ca href=\"\/products\/apc-dry-contact-i-o-smartslot-card-ap9613\"\u003eAP9613\u003c\/a\u003e Dry Contact I\/O SmartSlot Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring \u0026amp; Control\u003c\/td\u003e\n\u003ctd\u003eInput contacts and relay state shown in the host card's interface; configurable actions on state change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e23 x 46 x 46 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications (as printed by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003eEN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-6; RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhich cards take the AP9810.\u003c\/strong\u003e Any APC host with a universal I\/O port. In the current range that is the \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641\u003c\/a\u003e Network Management Card 3 with environmental monitoring (two ports) and the \u003ca href=\"\/products\/apc-dry-contact-i-o-smartslot-card-ap9613\"\u003eAP9613\u003c\/a\u003e Dry Contact I\/O SmartSlot Card (two ports); Schneider also lists the AP9631 and AP9635 Network Management Card 2 models. Schneider's technical guide for the accessory covers connection to an NMC3 host.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot for the AP9640 or AP9544.\u003c\/strong\u003e The \u003ca href=\"\/products\/apc-ups-network-management-card-3-ap9640\"\u003eAP9640\u003c\/a\u003e and the Easy UPS card AP9544 have no universal I\/O port, so the AP9810 has nowhere to plug in. If you need contacts on a Smart-UPS with a single SmartSlot, the AP9641 plus an AP9810 gives you network management and two inputs and a relay from one slot.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack ATS and Rack PDU sensor ports.\u003c\/strong\u003e The fifth-generation NetShelter Rack ATS units and sensor-port Rack PDUs are published as accepting the AP9335T and AP9335TH temperature sensors. Schneider does not list the AP9810 against those ports, so do not assume it works there - ask us to confirm for the specific unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePort budget.\u003c\/strong\u003e Each AP9810 occupies one universal I\/O port. On an AP9641 or AP9613 with two ports, that leaves one port for an \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH\u003c\/a\u003e temperature and humidity sensor or an AP9335T temperature sensor. On an AP9613 you can fit two AP9810 units for eight inputs and eight relays in total.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat the relay can drive.\u003c\/strong\u003e The Form C relay is a signalling contact: 1 A at 30 V DC normal switching, 2 A DC maximum, 60 V DC maximum, 30 W. Use it for alarm panel inputs, BMS digital inputs, a beacon or a PLC input. It is not a power switch and it is not rated for mains.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat the inputs read.\u003c\/strong\u003e Two volt-free contacts - normally open or normally closed, set in the host card's interface - plus a 12 V, 25 mA output for a sensor that needs a little power. Door contacts, leak rope controllers, fire panel auxiliary contacts and generator status relays are the usual candidates.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; APC UPS Management Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eIn the box.\u003c\/strong\u003e Dry Contact I\/O Accessory (AP9810), network cable for the universal I\/O port, documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHost cards for this accessory, in the SourceIT catalogue\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUniversal I\/O ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 - network management card; ships with an AP9335T temperature sensor in one port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-dry-contact-i-o-smartslot-card-ap9613\"\u003eAP9613\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 - dry contact card with 4 inputs and 6 relays of its own; two AP9810 units take it to 8 and 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-ap9640\"\u003eAP9640\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - not compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOther devices for the same ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP9810 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2 dry contact inputs, 1 Form C relay output, 12 V sensor supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335TH\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAPC Temperature \u0026amp; Humidity Sensor\u003c\/a\u003e - stocked by SourceIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335T\u003c\/td\u003e\n\u003ctd\u003eAPC Temperature Sensor - available to order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRack-level alternative\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNBRK0250A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNetBotz Rack Monitor 250 - 6 universal sensor ports, dry contact inputs, relay output and door access control in a 1U appliance, for sites that outgrow a card-based setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP9810. Links open in a new tab.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric product page\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/product\/AP9810\/apc-dry-contact-i-o-accessory\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Dry Contact I\/O Accessory AP9810 on se.com\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/SPD_JSAI-7PRKBU_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eDry Contact Accessory (AP9810) Technical Guide - connecting to a Network Management Card 3 host (990-3577)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eSchneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eAP9810\u003c\/strong\u003e and we will send you the current PDF datasheet and user guide directly.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP9810\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eHow many inputs and outputs does the AP9810 have?\u003c\/h3\u003e\n\u003cp\u003eTwo dry contact inputs, labelled Zone A and Zone B, one Form C relay output, and one 12 V DC, 25 mA power output for a small external sensor. Each AP9810 uses one universal I\/O port on the host card.\u003c\/p\u003e\n\u003ch3\u003eWhich cards does it work with?\u003c\/h3\u003e\n\u003cp\u003eCards with a universal I\/O port: the \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641\u003c\/a\u003e Network Management Card 3 with environmental monitoring, the \u003ca href=\"\/products\/apc-dry-contact-i-o-smartslot-card-ap9613\"\u003eAP9613\u003c\/a\u003e Dry Contact I\/O SmartSlot Card, and the earlier AP9631 and AP9635 Network Management Card 2. It does not fit the \u003ca href=\"\/products\/apc-ups-network-management-card-3-ap9640\"\u003eAP9640\u003c\/a\u003e or the Easy UPS AP9544, which have no such port.\u003c\/p\u003e\n\u003ch3\u003eCan I use it to get dry contacts on a Smart-UPS that only has one SmartSlot?\u003c\/h3\u003e\n\u003cp\u003eYes, and it is often the best answer. Fit an AP9641 for network management and plug an AP9810 into one of its universal I\/O ports. You get SNMP, HTTPS and PowerChute Network Shutdown from the card and two inputs plus a relay from the accessory, with the second port still free for a temperature sensor.\u003c\/p\u003e\n\u003ch3\u003eWhat can the relay switch?\u003c\/h3\u003e\n\u003cp\u003eSignalling loads: 1 A at 30 V DC normal switching, 2 A DC maximum switching and carrying current, 60 V DC maximum, 30 W maximum. That covers alarm panel inputs, BMS digital inputs, beacons and PLC inputs. Do not put mains or equipment load through it.\u003c\/p\u003e\n\u003ch3\u003eDoes it add contacts to an AP9613?\u003c\/h3\u003e\n\u003cp\u003eYes. The AP9613 has four inputs and six relays on its own; Schneider's manual for that card says adding AP9810 accessories lifts both counts to eight, using the card's two universal I\/O ports.\u003c\/p\u003e\n\u003ch3\u003eDoes it work on a Rack ATS or Rack PDU sensor port?\u003c\/h3\u003e\n\u003cp\u003eSchneider publishes those ports as accepting the AP9335T and AP9335TH sensors and does not list the AP9810 against them, so we do not claim it. Tell us the exact Rack ATS or PDU model and we will confirm before you order.\u003c\/p\u003e\n\u003ch3\u003eWhat is in the box, and how is it set up?\u003c\/h3\u003e\n\u003cp\u003eThe accessory, the network cable that connects it to the host's universal I\/O port, and documentation. Your own contacts connect to screw terminals on the accessory. Once plugged in, the host card detects it and the two inputs and the relay appear in that card's web interface, where you name each zone, set normal open or normal closed, and choose what happens on a state change - an e-mail, an SNMP trap, a log entry or, on a UPS card, a shutdown sequence. No separate software or power supply is needed; the accessory is fed from the host port.\u003c\/p\u003e\n\u003ch3\u003eDoes it come with a Singapore warranty?\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC AP9810 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs the AP9810 with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":51482595033252,"sku":"AP9810","price":230.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_c62d5e5a-ede1-4f04-98dd-ad0be080e9f5.jpg?v=1789712964","url":"https:\/\/sourceit.com.sg\/products\/apc-dry-contact-i-o-accessory-for-nmc-universal-i-o-port-ap9810","provider":"SourceIT ","version":"1.0","type":"link"}