{"title":"UPS \u0026 Power Protection","description":"\u003cp\u003eUninterruptible power supplies and power protection for Singapore businesses — APC by Schneider Electric, Eaton, Vertiv and Socomec, from desktop battery backup to online double-conversion UPS for server rooms and data centres, plus genuine replacement battery cartridges. Get sizing advice, GeBIZ quotes and volume pricing from SourceIT.\u003c\/p\u003e","products":[{"product_id":"apc-back-ups-pro-br-900va","title":"APC Back UPS Pro BR 900VA, 6 Outlets, AVR, LCD Interface","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Back UPS Pro BR 900VA, 6 Outlets, AVR, LCD Interface (BR900MI) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eAPC BR900MI 900 VA \/ 540 W UPS for Singapore's 230V \/ 50Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC BR900MI is a 900 VA \/ 540 W line-interactive UPS with stepped-approximation output, built for 230 V, 50 Hz supplies — exactly what Singapore's PUB grid delivers. It rides through the short dips, brownouts and momentary interruptions that follow an afternoon thunderstorm, and its Automatic Voltage Regulation corrects high and low mains voltage \u003cem\u003ewithout\u003c\/em\u003e going to battery, so the cells are not cycled every time the supply wanders. Output is 6 x C13, all battery-backed.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStepped-Approximation Output — Check Your PSU Before You Order\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BR900MI produces a stepped approximation to a sinewave on battery, which is what the Schneider data sheet states for this exact part number. That is entirely suitable for most desktop PCs, routers, switches, NVRs, POS terminals and comms-cabinet gear. If the load is an active-PFC ATX power supply that is fussy about waveform, specify a sine wave model instead — in the Back-UPS Pro BR range that is the \u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e or \u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e. We would rather tell you that up front than take the return.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutlets, Runtime and Battery Life in a Humid Climate\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOutlets are 6 x IEC 60320 C13 (battery backup and surge protection). The battery is a sealed maintenance-free lead-acid (VRLA) cartridge with a 3 to 5 year expected service life. Singapore's heat and humidity are hard on VRLA cells, so plan on a cartridge change inside that window rather than at the end of it; the replacement part is \u003ca href=\"\/products\/apc-replacement-battery-cartridge-164-apcrbc164\"\u003eAPCRBC164\u003c\/a\u003e. Schneider does not publish a runtime-versus-load table for the BR900MI, so we do not print one — runtime depends entirely on how much of the 540 W you actually draw. Tell us your load in watts and we will size it for you.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSME Office, Home Office and Comms-Cabinet Duty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis is a tower unit at 190 mm (H) x 91 mm (W) x 310 mm (D), 7.1 kg — it sits on a desk, under a counter or on the floor of a comms cupboard rather than in a rack, so it costs you no rack U. Everything SourceIT ships is local Singapore stock with a GST invoice and local warranty support — no grey imports, no chasing an overseas RMA.\u003c\/p\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC BR900MI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eEvery figure below is taken from the Schneider Electric product page (United Kingdom) and the APC BR900MI product data sheet as carried by two independent distributor mirrors that agree. Where Schneider does not publish a value for this exact part number, the row is left out rather than filled in from a similar model.\u003c\/p\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eBR900MI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro, 900VA\/540W, Tower, 230V, 6x IEC C13 outlets, AVR, LCD, User Replaceable Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro BR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive with Automatic Voltage Regulation (AVR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e900 VA \/ 540 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003eRepair or replace; Schneider states 2 years for the rest of the world and 3 years inside the European Community, so Singapore takes the 2-year term\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupported locally by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e540 W \/ 900 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 1 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform (on battery)\u003c\/td\u003e\n\u003ctd\u003eStepped approximation to a sinewave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003e6 x IEC 60320 C13 (battery backup and surge protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e10 ms typical, 12 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Filtering\u003c\/td\u003e\n\u003ctd\u003eFull-time multi-pole noise filtering, 10% of IEEE surge let-through, instantaneous response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e176 to 294 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 3 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e10 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003eAutomatic Voltage Regulation (AVR) — corrects high and low mains voltage without switching to battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed maintenance-free lead-acid (VRLA), user replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e9.4 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Rating\u003c\/td\u003e\n\u003ctd\u003e128 VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e12 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Battery Life\u003c\/td\u003e\n\u003ctd\u003e3 to 5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Runtime\u003c\/td\u003e\n\u003ctd\u003eNo external battery pack is documented for this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Load\u003c\/td\u003e\n\u003ctd\u003eSchneider publishes no runtime-versus-load figures for this model — contact SourceIT with your load in watts for a sizing calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Interface\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Alarms\u003c\/td\u003e\n\u003ctd\u003eAlarm when on battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eNot available on this model — there is no SmartSlot for an internal network management card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e190 mm (H) x 91 mm (W) x 310 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e7.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Mountable\u003c\/td\u003e\n\u003ctd\u003eNo — tower form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-15 to 45 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e45 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, RCM, C-Tick, A-Tick, EAC, TISI, GS Mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e0731304346944\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe BR900MI presents 6 x C13, all battery-backed. All outlets are IEC 60320 C13, so a standard C13 kettle lead connects a PC, monitor, switch, router or NAS directly. Every outlet on this model is battery-backed and surge protected. The unit takes its own supply through an IEC 60320 C14 inlet on a normal 13 A Singapore wall socket — no dedicated circuit and no electrician needed.\u003c\/p\u003e\n\u003ch4\u003eSizing it: VA, watts and how much you can actually load\u003c\/h4\u003e\n\u003cp\u003eThe BR900MI is rated 900 VA apparent power and 540 W real power. Size against the \u003cstrong\u003ewatts\u003c\/strong\u003e, not the VA — the watt figure is the one that runs out first on modern IT loads. As a working rule, keep the connected load under about 70% of 540 W so you have headroom for inrush and for the battery ageing. Schneider publishes no runtime table for this model, so any minutes figure you see quoted elsewhere is someone's estimate, not a manufacturer specification. Send us your equipment list and we will work out the real number.\u003c\/p\u003e\n\u003ch4\u003eBattery and replacement cartridge\u003c\/h4\u003e\n\u003cp\u003eThe battery is a sealed maintenance-free lead-acid (VRLA) cartridge, 12 V 9.4 Ah. Typical recharge time is 12 h. The APC replacement cartridge for this model is \u003cstrong\u003eAPCRBC164\u003c\/strong\u003e — \u003ca href=\"\/products\/apc-replacement-battery-cartridge-164-apcrbc164\"\u003eAPCRBC164\u003c\/a\u003e is stocked by SourceIT. The cartridge is user-replaceable from the front of the unit; APC does not describe this model's battery as swappable while running, so plan a short shutdown for the change.\u003c\/p\u003e\n\u003ch4\u003eRack space and management software\u003c\/h4\u003e\n\u003cp\u003eThis is a tower unit and is not rack mountable, so it consumes no rack U and needs no rail kit. This model has no SmartSlot, so an AP9640 or AP9641 Network Management Card cannot be fitted — if you need SNMP monitoring or an Ethernet-managed UPS, step up to the APC Smart-UPS range and we will quote it. Bundled shutdown software is not documented for this model in the Schneider material we can verify, so we do not claim it; ask us and we will confirm what ships in the current carton.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Back-UPS Pro BR Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cp\u003eSchneider does not itemise the carton contents for this model in the documentation we can verify, so we will not invent a list. What we can tell you is that the unit ships as a complete tower UPS with its battery installed. If the exact carton contents matter for your tender or your install, ask us before you order and we will open a unit and tell you what is actually in it.\u003c\/p\u003e\n\u003ch4\u003eAPC Back-UPS and Back-UPS Pro BR range at SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-500va-300w-tower-230v-br500ci-as\"\u003eBR500CI-AS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS, 500VA \/ 300W tower, 3x C13 — 500 VA \/ 300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-650va\"\u003eBR650MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 650VA \/ 390W tower, 6x C13 — 650 VA \/ 390 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBR900MI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBack-UPS Pro, 900VA \/ 540W tower, 6x C13 — 900 VA \/ 540 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1200VA \/ 720W tower, 8x C13, sine wave, USB A+C — 1200 VA \/ 720 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-1300va\"\u003eBR1300MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1300VA \/ 780W tower, 8x C13 — 1300 VA \/ 780 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1500va-865w-tower-230v-10x-iec-c13-outlets-avr-lcd-br1500gi\"\u003eBR1500GI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1500VA \/ 865W tower, 10x C13, external pack capable — 1500 VA \/ 865 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1600va-960w-tower-230v-br1600mi\"\u003eBR1600MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13 — 1600 VA \/ 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13, sine wave, USB A+C — 1600 VA \/ 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-external-battery-pack-for-1500va-back-ups-pro-models-br24bpg\"\u003eBR24BPG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro external battery pack, 24 V \/ 372 VAh (for BR1500GI) — Battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMatching replacement battery cartridge\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003eAPCRBC164\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for the BR900MI — \u003ca href=\"\/products\/apc-replacement-battery-cartridge-164-apcrbc164\"\u003eAPCRBC164\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003cp\u003eRail kits and network management cards do not apply to this range: every Back-UPS Pro BR model is a tower with no SmartSlot. For rack-mount or network-managed power protection, ask us about the APC Smart-UPS SMT, SMC and SMX ranges.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eLinks open on Schneider Electric's own site. Each one was checked before publication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/BR900MI\/apc-backups-pro-900va-540w-tower-230v-6x-iec-c13-outlets-avr-lcd-user-replaceable-battery\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for the APC BR900MI\u003c\/a\u003e — official product name, characteristics and the full document list (United Kingdom site)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/SPD_AHUG-B59B4X_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Back-UPS Pro BR650\/900\/1300\/1600MI User Manual (Schneider document library)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's direct datasheet PDF links sit behind a path that blocks automated retrieval, so we link the product page and the document library entry instead — every link above resolves and carries the current document. If you need the datasheet or manual emailed to you as a file for a tender submission, ask us and we will send it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC BR900MI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 900 VA and the 540 W rating?\u003c\/h4\u003e\n\u003cp\u003e900 VA is apparent power and 540 W is real power. Your equipment consumes real power, so the 540 W figure is the one that limits what you can connect. Add up the wattage on the nameplates of everything you intend to back up and keep the total comfortably below 540 W.\u003c\/p\u003e\n\u003ch4\u003eHow long will the BR900MI run my equipment?\u003c\/h4\u003e\n\u003cp\u003eIt depends entirely on load, and Schneider publishes no runtime table for this model — which is why you will not find minutes quoted on this page. A lightly loaded unit runs for many minutes; one near 540 W runs for a few. Send SourceIT your load in watts and we will calculate it against the 128 VAh battery rating rather than guess.\u003c\/p\u003e\n\u003ch4\u003eWhat does the \"MI\" in BR900MI mean?\u003c\/h4\u003e\n\u003cp\u003eIt identifies the build variant. MI is the 230 V IEC-outlet build sold across Asia, the Middle East and Europe, with a stepped-approximation output waveform and no USB charging ports. These suffixes are not interchangeable — outlet counts, waveform and battery cartridge all change with them, so order by the exact part number.\u003c\/p\u003e\n\u003ch4\u003eIs the output a pure sine wave, and will it drive an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eNo. The BR900MI produces a stepped approximation to a sinewave, as stated in its data sheet. That is fine for most desktops, routers, switches, NVRs and POS gear, but some active-PFC ATX power supplies will alarm or drop out on it. If your load has an active-PFC supply, choose the \u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e or \u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e instead — both are sine wave.\u003c\/p\u003e\n\u003ch4\u003eWhich replacement battery does it take, and can I fit it myself?\u003c\/h4\u003e\n\u003cp\u003eThe APC replacement battery cartridge for the BR900MI is \u003cstrong\u003eAPCRBC164\u003c\/strong\u003e, stocked here: \u003ca href=\"\/products\/apc-replacement-battery-cartridge-164-apcrbc164\"\u003eAPCRBC164\u003c\/a\u003e. It is user-replaceable — no tools beyond a screwdriver and no service call. APC does not describe this model's battery as swappable while running, so shut the unit down for the swap. Expect three to five years of service in an air-conditioned office, and less in a hot, humid comms cupboard.\u003c\/p\u003e\n\u003ch4\u003eCan I rack mount it or add a network management card?\u003c\/h4\u003e\n\u003cp\u003eNo on both counts. The BR900MI is a tower unit with no rack ears or rail kit option, and the Back-UPS Pro BR range has no SmartSlot, so an AP9640 or AP9641 card cannot be fitted. If you need a 19-inch rack UPS or SNMP monitoring, ask SourceIT about the APC Smart-UPS SMT, SMC and SMX ranges.\u003c\/p\u003e\n\u003ch4\u003eHow does the BR900MI compare with the BR650MI?\u003c\/h4\u003e\n\u003cp\u003eThe \u003ca href=\"\/products\/apc-back-ups-pro-br-650va\"\u003eBR650MI\u003c\/a\u003e drops to 650 VA \/ 390 W in an identically sized chassis if your load is lighter. Both are stocked by SourceIT in Singapore — tell us the load and the budget and we will tell you which one is the right buy.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC BR900MI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the BR900MI with a 2-year manufacturer warranty. Note that Schneider states three years inside the European Community and two years elsewhere — Singapore takes the two-year term, and any listing quoting three years for this market has copied the European figure.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/dZ-hRA5gJ48\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879303127204,"sku":"BR900MI","price":425.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_a17f3b56-c67a-4b8a-bbbc-048dafc6625f.jpg?v=1789718814"},{"product_id":"apc-smart-ups-rt-19-rail-kit-for-smart-ups-rt-3-5-7-5-10kva","title":"APC Smart-UPS RT Rail Kit for 3\/5\/7.5\/10kVA UPS","description":"\u003ch2\u003e\u003cstrong\u003eAPC Smart-UPS RT Rail Kit for 3\/5\/7.5\/10kVA UPS (SURTRK2) - 1 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eEnhance Your APC Smart-UPS RT\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUpgrade your APC Smart-UPS RT 3\/5\/7.5\/10kVA installation with the SURTRK2 Rail Kit, designed specifically for these models. This rail kit lets you securely mount your Smart-UPS RT in a standard 19-inch rack, saving valuable space in your data center or server room while keeping heavy UPS hardware properly supported and accessible for servicing.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEasy Installation Process\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SURTRK2 Rail Kit is easy to install, making it simple to configure your UPS system quickly and efficiently. Step-by-step instructions are included with the kit to ensure a hassle-free installation, so you can have your Smart-UPS RT mounted and running in minimal time without specialized tools or expertise.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDurable Design for Reliable Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eConstructed from heavy-duty steel, the SURTRK2 provides reliable support for your Smart-UPS RT. Its sturdy design ensures the UPS is securely mounted, reducing the risk of damage or instability in your rack. This durable build gives you confidence that the unit stays firmly in place over the long term.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOptimize Space and Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBy securely mounting your UPS, the SURTRK2 helps you optimize rack space and keep equipment organized and easily accessible. The kit is compatible with a range of Smart-UPS RT models, including 3kVA, 5kVA, 7.5kVA, and 10kVA systems, offering an adjustable fit for various rack depths and configurations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Rackmount Rail Kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e SURTRK2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for 3kVA, 5kVA, 7.5kVA, and 10kVA models of APC Smart-UPS RT (including SRT3K, SRT5K, SRT7.5K, and SRT10K)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePurpose:\u003c\/strong\u003e Enables easy installation of Smart-UPS RT models into a standard 19-inch server rack; provides secure, adjustable mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Heavy-duty steel construction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Style:\u003c\/strong\u003e Adjustable rack-mountable design; 2U and 3U compatibility depending on the UPS model\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Typically around 482mm width x 530mm depth (adjustable based on UPS size)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 4 kg (8.8 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeatures:\u003c\/strong\u003e Includes all necessary hardware for installation; secure mounting that slides in and out of the rack; adjustable design for varying UPS depths\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e UL, CE compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal Use Case:\u003c\/strong\u003e Data centers and server rooms mounting APC Smart-UPS RT 3\/5\/7.5\/10kVA units securely into standard 19-inch racks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGTIN\/UPC:\u003c\/strong\u003e 731304271065\u003c\/p\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879306141860,"sku":"SURTRK2","price":375.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-smart-ups-rt-19-rail-kit-for-smart-ups-rt-357510kva-1-years-local-warranty-862407.jpg?v=1654153898"},{"product_id":"apc-service-bypass-pdu-230v-16amp-w-6-iec-c13-and-1-c19","title":"APC Bypass PDU 230V 16A, 6xC13, 1xC19","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Service Bypass PDU, 2U, 230V 16A, (6) C13 \u0026amp; (1) C19, C20 Inlet (SBP3000RMI) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eService Your UPS Without Dropping the Load\u003c\/h3\u003e\n\u003cp\u003eThe APC Service Bypass PDU (SBP3000RMI) sits between your rack UPS and the equipment it feeds, so the UPS can be serviced, have its batteries replaced, or be swapped out entirely while the connected load keeps running on utility power.\u003c\/p\u003e\n\u003cp\u003eSchneider describes two positions. In the normal position the load is fed FROM UPS OUTPUT, with full battery backup. In BYPASS the load is fed directly from utility, with no battery support - and the UPS can then be unplugged and removed. It turns a full shutdown into a short maintenance window. Schneider's documents disagree on whether the transfer is make-before-break or break-before-make, so plan for a brief interruption and ask us to confirm before scheduling a live transfer.\u003c\/p\u003e\n\u003ch3\u003eThe Piece Most Singapore Racks Are Missing\u003c\/h3\u003e\n\u003cp\u003eSealed lead-acid batteries in a Singapore comms room typically want replacing every three to five years, and eventually the UPS itself reaches end of life. Without a bypass panel, both jobs mean shutting down whatever the UPS feeds - which in practice means either a weekend call-out or a deferred battery replacement that quietly leaves the rack unprotected.\u003c\/p\u003e\n\u003cp\u003eWith an SBP3000RMI fitted from the start, battery replacement and UPS swap-out become in-hours work. For any rack where downtime has to be scheduled with a business owner, that changes the economics of maintenance.\u003c\/p\u003e\n\u003ch3\u003e16A, Six C13 and One C19 Outlets in 2U\u003c\/h3\u003e\n\u003cp\u003eThe unit is rated 16 A at 230 V (220 to 240 VAC, 50\/60 Hz) for a maximum load of 3,000 VA, fed through an IEC 60320 C20 inlet on a 2.5 m cord. Output is six IEC C13 outlets plus one C19, with an IEC jumper included.\u003c\/p\u003e\n\u003cp\u003eIt occupies 2U of rack space at 432 mm wide, 89 mm high and 76 mm deep, and weighs 2.09 kg. Rack mounting brackets and the user manual are supplied.\u003c\/p\u003e\n\u003ch3\u003eA Passive Panel - Metering, Networking and Surge Are Not Provided\u003c\/h3\u003e\n\u003cp\u003eThis is deliberately simple hardware: a manual transfer arrangement and a set of outlets. Metering, a display, network management and surge protection are not provided. That simplicity is a virtue in a device whose whole job is to still work when it is needed years after installation.\u003c\/p\u003e\n\u003cp\u003eSurge protection and power conditioning are the UPS's job, which is exactly why the panel exists - so the UPS can be kept in good order. Supplied and invoiced locally in Singapore with GST.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SBP3000RMI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSBP3000RMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Service Bypass PDU, 230V 16AMP W\/ (6) IEC C13 AND (1) C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eMaintenance bypass - transfers the load to utility so the UPS can be serviced or removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e2U rack-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e0731304266747\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eYes - supplied and supported locally by SourceIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e220 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C20 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e2.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOutput \u0026amp; Receptacles\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load\u003c\/td\u003e\n\u003ctd\u003e3,000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC13 Outlets\u003c\/td\u003e\n\u003ctd\u003e6 x IEC 60320 C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC19 Outlets\u003c\/td\u003e\n\u003ctd\u003e1 x IEC 60320 C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Jumper\u003c\/td\u003e\n\u003ctd\u003e1 IEC jumper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBypass Operation \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Position\u003c\/td\u003e\n\u003ctd\u003eFROM UPS OUTPUT - load fed through the UPS with battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBypass Position\u003c\/td\u003e\n\u003ctd\u003eBYPASS - load fed from utility only, no battery support; the UPS can be removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eNot provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eNot provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eNot provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided - surge protection is the function of the UPS this panel serves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e432 x 89 x 76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e2.09 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 4,500 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-15 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eVDE; RoHS and REACH compliant (no SVHCs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eBypass PDU, rack mounting brackets, user manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Load Planning\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhich UPS models this panel is for.\u003c\/strong\u003e Schneider's own user guide for this unit is titled \"Service Bypass Panel Smart-UPS 1500\/2200\/3000 RM Series\" - that is, rack-mount Smart-UPS units of 1500, 2200 and 3000 VA. The se.com product page adds that it is designed for APC InfraStruXure Type A, Smart-UPS and Symmetra products. Its 16 A rating and 3,000 VA maximum load are the electrical ceiling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack-mount Smart-UPS in the SourceIT catalogue that sit in this band\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-1500va-lcd-rm-1u-230v-smt1500rmi1u\"\u003eSMT1500RMI1U\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 1500VA LCD RM 1U 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-1500va-lcd-rm-2u-230v-with-smartconnect-smt1500rmi2uc\"\u003eSMT1500RMI2UC\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 1500VA LCD RM 2U 230V with SmartConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-2200va-lcd-rm-2u-230v-with-smartconnect-smt2200rmi2uc\"\u003eSMT2200RMI2UC\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 2200VA LCD RM 2U 230V with SmartConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-3000va-lcd-rm-2u-230v-smt3000rmi2u\"\u003eSMT3000RMI2U\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 3000VA LCD RM 2U 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eSend us your exact UPS part number before ordering and we will confirm the pairing against Schneider's documentation rather than inferring it from the VA rating alone. Note that the Smart-UPS X family is not named in this panel's user guide title, so a Smart-UPS X pairing needs confirming specifically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnector check.\u003c\/strong\u003e The panel's inlet is an IEC 60320 C20, and Schneider specifies a 2.5 m cord; ask us to confirm how that cord is terminated for your supply. Output is six C13 and one C19 - if your equipment needs more C19 positions than one, or more than seven outlets in total, this panel will need a rack PDU downstream of it, or a larger panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoad ceiling.\u003c\/strong\u003e 16 A and 3,000 VA maximum. That is the whole panel, not per outlet. Total the connected load before specifying, and remember that in bypass the same load runs on raw utility with no UPS protection at all.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack space.\u003c\/strong\u003e 2U, 432 x 89 x 76 mm, 2.09 kg. Budget 2U in addition to the UPS itself - a 2U UPS plus this panel is 4U of cabinet. Rack mounting brackets are supplied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it does not do.\u003c\/strong\u003e No metering, no display, no network management and no surge protection. If you need remote visibility of the load, that is a metered rack PDU downstream - and it must be one this panel can actually feed, which means a 16 A unit with a C20 inlet such as the \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e, not a 32 A model. If you need automatic transfer between two independent supplies rather than a manual maintenance bypass, that is a Rack ATS such as the \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423\u003c\/a\u003e - a different product solving a different problem.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLarger loads.\u003c\/strong\u003e For 32 A and up to 7,680 VA, with eight C13 and two C19 outlets and a choice of C20 or hardwire input, see the \u003ca href=\"\/products\/apc-service-bypass-panel-230v-sbp5000rmi2u\"\u003eSBP5000RMI2U\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; APC Service Bypass Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eIn the box:\u003c\/strong\u003e the bypass PDU, rack mounting brackets and user manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPC service bypass panels in the SourceIT catalogue\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRating and outlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSBP3000RMI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2U, 230 V, 16 A, 3,000 VA - 6 C13 + 1 C19, C20 inlet\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-service-bypass-panel-230v-sbp5000rmi2u\"\u003eSBP5000RMI2U\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2U, 230 V, 32 A, 7,680 VA - 8 C13 + 2 C19, C20 or hardwire input, Break Before Make switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRack-mount Smart-UPS this panel is intended to serve\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-1500va-lcd-rm-2u-230v-with-smartconnect-smt1500rmi2uc\"\u003eSMT1500RMI2UC\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 1500VA LCD RM 2U 230V with SmartConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-2200va-lcd-rm-2u-230v-with-smartconnect-smt2200rmi2uc\"\u003eSMT2200RMI2UC\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 2200VA LCD RM 2U 230V with SmartConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-3000va-lcd-rm-2u-230v-smt3000rmi2u\"\u003eSMT3000RMI2U\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 3000VA LCD RM 2U 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRack power and monitoring to go downstream of it\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU Basic, 1U, 16 A - 10 C13 + 2 C19, for racks needing more outlets than the panel provides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU Metered, 0U, 16 A, 3.7 kW - 18 C13 + 2 C19, C20 inlet, so it can be fed from this panel's C19 outlet; adds the load visibility the panel does not provide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack ATS, 1U, 16 A - automatic transfer between two supplies, a different function from manual maintenance bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC SBP3000RMI. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/SBP3000RMI\/apc-service-bypass-pdu-230v-16amp-w-6-iec-c13-and-1-c19\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page - APC Service Bypass PDU SBP3000RMI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/at\/de\/download\/document\/SPD_ABRE-7TSP2E_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eService Bypass Panel Smart-UPS 1500\/2200\/3000 RM Series user guide (SPD_ABRE-7TSP2E_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/eg\/en\/faqs\/FAQ000270396\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric FAQ FAQ000270396 - service bypass panel modes of operation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/cz\/cs\/faqs\/FA240007\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric FAQ FA240007 - what a service bypass panel does\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed a specific document, a compliance declaration or a written quotation? Contact SourceIT and we will supply it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SBP3000RMI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat does a service bypass panel actually do?\u003c\/h4\u003e\n\u003cp\u003eIt lets you take the UPS out of the power path without dropping the load. In the normal position the load runs FROM UPS OUTPUT with full battery backup. Switch to BYPASS and the load runs directly on utility power, with no battery support, at which point the UPS can be unplugged, serviced, have its batteries changed, or be replaced entirely. Without one, every UPS battery replacement is a shutdown.\u003c\/p\u003e\n\u003ch4\u003eHow much rack space does it take - is it 1U or 2U?\u003c\/h4\u003e\n\u003cp\u003e2U. The unit measures 432 x 89 x 76 mm (W x H x D) and weighs 2.09 kg. Budget that on top of the UPS itself, so a 2U rack UPS plus this panel occupies 4U of cabinet. Rack mounting brackets are supplied.\u003c\/p\u003e\n\u003ch4\u003eWhich UPS models does it suit?\u003c\/h4\u003e\n\u003cp\u003eSchneider's user guide for the unit covers the Smart-UPS 1500, 2200 and 3000 VA RM series, and the product page adds APC InfraStruXure Type A, Smart-UPS and Symmetra products. Its electrical ceiling is 16 A and 3,000 VA. Schneider does not publish a per-model compatibility table we can verify, so send us your UPS part number and we will confirm the pairing before you order.\u003c\/p\u003e\n\u003ch4\u003eWhat are the input and output connectors?\u003c\/h4\u003e\n\u003cp\u003eInput is an IEC 60320 C20 inlet, with a 2.5 m cord specified; ask us to confirm how it is terminated for your supply. Output is six IEC C13 outlets plus one C19, and an IEC jumper is included. If your rack needs more outlets than that, put a suitably rated rack PDU downstream of the panel.\u003c\/p\u003e\n\u003ch4\u003eIs my load protected while the panel is in bypass?\u003c\/h4\u003e\n\u003cp\u003eNo, and this is the point to be clear about with whoever owns the equipment. In BYPASS the load runs on raw utility power with no battery backup and no UPS conditioning. That is intentional - it is what allows the UPS to be removed - but it means bypass is a maintenance state, not a normal running state. Keep the window short and avoid scheduling it during periods of unstable supply.\u003c\/p\u003e\n\u003ch4\u003eDoes it provide metering, network management or surge protection?\u003c\/h4\u003e\n\u003cp\u003eNone of the three are provided. It is a passive panel with outlets, and Schneider's technical documentation for it carries no metering, display, networking or surge fields. For load visibility, add a suitably rated metered rack PDU downstream - one with a 16 A C20 inlet that this panel can actually feed. For surge protection and ride-through, that is the UPS's job - which is precisely why this panel exists, so the UPS can be properly maintained.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC SBP3000RMI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SBP3000RMI with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879309877412,"sku":"SBP3000RMI","price":705.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-service-bypass-pdu-230v-16amp-w-6-iec-c13-and-1-c19-1-years-local-warranty-848634.jpg?v=1654153909"},{"product_id":"apc-rack-pdu-switched-1u-16a-208-230v-8c13","title":"APC Rack PDU, Switched, 1U, 16A, 208\/230V, (8)C13","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Switched Rack PDU, 1U, 1 Phase, 3.7kW 230V 16A, (8) C13 Outlets, C20 Cord (AP7921B) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eRemote Outlet Control for Equipment That Locks Up\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Switched Rack PDU AP7921B lets you switch each of its eight IEC C13 outlets on and off individually over the network. Power-cycling a frozen firewall or switch becomes a browser action rather than a site visit - the difference between minutes and hours of downtime when the equipment sits in a co-location cage or an unstaffed branch office.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e16 A and 3.7 kW on Singapore Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFed through an IEC C20 inlet on a 2.4 m cord, the AP7921B carries 16 A total for 3.7 kW at 230 V, with 10 A available per outlet under IEC rules. That is roughly 60% more capacity than its C14-fed sibling, which makes it the switched PDU to choose when servers rather than just network gear are involved.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eNetwork Management Is Built In - Not Optional\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWeb, Telnet, SNMP and SSH access come as standard, reporting into EcoStruxure IT Expert, and a one-year Secure Network Management Card subscription is included. Network connectivity is sometimes described as an option on this part; it is not - there is no card to buy and nothing to fit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLocal Metering in a Compact 1U Chassis\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA digital display shows aggregate current at the unit, measured to ±5%, so you can see the load at the rack as well as from your desk. The chassis is 44.5 mm high, 444.5 mm wide and 108 mm deep at 2.26 kg - shallow enough for a comms cabinet, light enough to retrofit into a rack that is already cabled.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP7921B Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Switched Rack PDU, 1U, 1PH, 3.7 kW 230 V 16 A or 3.3 kW 208 V 16 A, 8 C13 outlets, C20 cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP7921B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSwitched Rack Power Distribution Unit (PDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e1U, 19-inch horizontal rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eCommercialised (current product)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C20 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e2.4 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e200-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e16 A total and 10 A per outlet (IEC markets, including Singapore); 16 A total and 12 A per outlet (UL); 12 A total (cUL, Canada only - not applicable in Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacity\u003c\/td\u003e\n\u003ctd\u003e3,680 VA - 3.7 kW at 230 V; 3.3 kW at 208 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eEight (8) IEC 60320 C13\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMetering, Switching \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd\u003eIndividual on\/off control of every outlet, remotely over the network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Display\u003c\/td\u003e\n\u003ctd\u003eDigital display showing aggregate current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% (amps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eBuilt in as standard - no separate card required, and not an optional extra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interfaces\u003c\/td\u003e\n\u003ctd\u003eWeb, Telnet, SNMP, SSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Platform\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure IT Expert. A one-year Secure Network Management Card subscription is included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided - no surge suppression is specified for this product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e44.5 x 444.5 x 108.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e2.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 3,048 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003ecULus-EU, CE, RCM, EAC, CMIM, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15, ICES-003, EN 55024, EN 55032, AS\/NZS CISPR 32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e731304331629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Load Planning\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Eight IEC C13 outlets taking standard C14 equipment cords, with\n10 A available per outlet under IEC rules. That covers switches, routers, firewalls, appliances and 1U or 2U\nservers. There are no C19 outlets on this model - a device with a 16 A C20 inlet cannot be connected, and\nshould not be adapted down onto a C13.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLoad planning.\u003c\/strong\u003e 16 A total, 3.7 kW at 230 V. Eight outlets share that budget,\nso about 2 A each on average - comfortable for network equipment and workable for a few modest servers. The\nlocal display and the network interface both report aggregate current to ±5%, so you can watch the headroom\nrather than estimate it.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e 1U high, 444.5 mm wide, 108 mm deep, 2.26 kg. Fits any 19-inch rack\nincluding shallow comms cabinets. Rack mounting brackets, a user manual and an installation guide are supplied.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeeding it.\u003c\/strong\u003e An IEC C20 inlet with a 2.4 m cord supplied. That is a step up from the\n\u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B\u003c\/a\u003e, which plugs into an ordinary C13 socket - the AP7921B wants a\n16 A supply, ideally from a UPS or a 16 A outlet on a row PDU.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eManagement.\u003c\/strong\u003e Built in, not optional: Web, Telnet, SNMP and SSH, reporting into EcoStruxure IT\nExpert, with a one-year Secure NMC subscription included. The AP9640 and AP9641 cards we sell are Smart-UPS\naccessories and have nothing to do with this PDU. Schneider does not document an environmental sensor port on\nthis model, so we do not claim one.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat it does not do.\u003c\/strong\u003e No surge protection - the specification guide contains no surge section,\nso do not plan on it. And no battery: a switched PDU controls power, it\ndoes not store it, so a UPS is still required for ride-through.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Metered and Switched Rack PDU Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC NetShelter Switched Rack PDU (AP7921B) with 2.4 m IEC C20 input cord\u003c\/li\u003e\n\u003cli\u003eRack mounting brackets\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMetered \u0026amp; Switched Rack PDU Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 10 A, 2.3 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C14 inlet, 2.4 m cord supplied\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP7921B (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitched\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 16 A, 3.7 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC C20 inlet, 2.4 m cord supplied\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(8) C13\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, no cord supplied\u003c\/td\u003e\n\u003ctd\u003e(18) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-metered-2u-32a-230v-12-c13-4-c19\"\u003eAP7822B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(12) C13, (4) C19\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(36) C13, (6) C19\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP7921B. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-5826_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Switched Rack PDU AP7921B - Overview and Specifications (990-5826_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/product\/AP7921B\/apc-netshelter-switched-rack-pdu-1u-1ph-3-7kw-230v-16a-or-3-3kw-208v-16a-8-c13-outlets-c20-cord\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric AP7921B product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/id\/en\/faqs\/FAQ000277528\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric Rack PDU warranty policy (FAQ000277528)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP7921B\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eIs network management optional on the AP7921B?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo - it is built in. Web, Telnet, SNMP and SSH access are standard, the unit reports into EcoStruxure IT Expert, and a one-year Secure Network Management Card subscription is included. Network connectivity is sometimes described as optional against this part number in third-party data; it is not.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat can I do remotely with a Switched PDU?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTurn any individual outlet on or off, power-cycle a hung device, and define the sequence and delays in which outlets come up after a power failure. That is the practical difference from a Metered PDU, which shows you the load but cannot act on it.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow much load will it take?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e16 A total, 3.7 kW at 230 V, with 10 A available per outlet under IEC rules. Eight outlets share the 16 A, so plan against total nameplate current rather than outlet count.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider's specification guide for the AP7921B contains no surge section, joule rating or clamping figure. Put a UPS upstream if you need surge and sag protection - that is not a PDU function.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does it compare with the AP7920B?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSame 1U chassis, same eight C13 outlets, and the same built-in remote switching and network management. The \u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B\u003c\/a\u003e is 10 A \/ 2.3 kW with a C14 inlet that plugs into any ordinary C13 socket; the AP7921B is 16 A \/ 3.7 kW with a C20 inlet needing a 16 A cord. If your load is only switches and appliances, the AP7920B is enough; if servers are involved, take the AP7921B.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan I meter individual outlets?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. The AP7921B switches per outlet but meters aggregate current only, shown on the local display and over the network. Per-outlet measurement is a separate product class (Switched Metered-by-Outlet) - ask us if that is what your application needs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs it a current product?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes - Schneider records the AP7921B as Commercialised, with no end-of-life date. It is one of the few models in this rack power range with no discontinuation notice against it.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Switched Rack PDU AP7921B sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the AP7921B with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879311384740,"sku":"AP7921B","price":945.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_b2398a5c-0ab2-4ee0-96bd-86a6f39c624f.jpg?v=1789718886"},{"product_id":"apc-rack-pdu-metered-2u-32a-230v-12-c13-4-c19","title":"APC Rack PDU, Metered, 2U, 32A, 230V, (12) C13 \u0026 (4) C19","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Metered Rack PDU, 2U, 1 Phase, 7.4kW 230V 32A, (12) C13 \u0026amp; (4) C19, IEC 309 Cord (AP7822B) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKnow What the Rack Is Actually Drawing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Metered Rack PDU AP7822B measures the current on each of its two 16 A banks and shows the aggregate on a digital display, so you can see the real load instead of estimating it from nameplates. Amps are measured to within ±5%, which is enough to balance banks, spot creeping growth and avoid the overload that trips a breaker at the worst possible moment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e7.4 kW of Capacity Through Sixteen Outlets\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA 32 A IEC 60309 cord feeds twelve IEC C13 outlets rated to 10 A each and four IEC C19 outlets rated to 16 A each, for 7.4 kW total at 230 V. Four C19 outlets is a generous allocation - enough for a pair of blade chassis and two storage shelves in the same rack.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTwo Protected Banks\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe outlets sit behind two single-pole 16 A circuit breakers, so a fault or overload on one bank leaves the other running. The display reports current per bank, which makes balancing the load across the two a matter of reading a number rather than guessing.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eNetwork Management Built In, in a 2U Chassis\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRemote monitoring over Web, Telnet, SNMP and SSH is standard, with reporting into EcoStruxure IT Data Center Expert - no card to buy. The 2U chassis is 88.3 mm high, 443.7 mm wide and only 112 mm deep, and weighs 2.76 kg, so it mounts easily in a Singapore server room or comms cabinet where power visibility has become an operational requirement rather than a nice-to-have.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP7822B Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Metered Rack PDU, 2U, 1PH, 7.4 kW 230 V 32 A, x12 C13 and x4 C19 outlets, IEC 309 cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP7822B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMetered Rack Power Distribution Unit (PDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e2U, 19-inch horizontal rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60309, 32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e12 ft (3.66 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e220-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacity\u003c\/td\u003e\n\u003ctd\u003e7.4 kW at 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eTwelve (12) IEC 60320 C13 and four (4) IEC 60320 C19 - 16 outlets total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e220-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per C13 Outlet\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per C19 Outlet\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Bank\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003ctd\u003eTwo (2) single-pole 16 A circuit breakers, one per bank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMetering, Switching \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eAggregate current per bank, shown on a digital display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% (amps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd\u003eNone - this is a Metered model, not a Switched one\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eBuilt in as standard - no separate card required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interfaces\u003c\/td\u003e\n\u003ctd\u003eWeb, Telnet, SNMP, SSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Platform\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure IT Data Center Expert (formerly StruxureWare Data Center Expert)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided - no surge suppression is specified for this product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e88.3 x 443.7 x 112.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e2.76 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e4.44 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 15,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Approvals\u003c\/td\u003e\n\u003ctd\u003eVDE, CE, EAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 55022, EN 55024, CISPR 22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e0731304331520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Load Planning\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Twelve IEC C13 outlets, 10 A each, for C14-corded servers,\nswitches and appliances. Four IEC C19 outlets, 16 A each, for C20-corded blade chassis, storage shelves and\nlarge core switches. Four C19 outlets is the most of any 1U or 2U model in this range.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLoad planning and banks.\u003c\/strong\u003e 32 A input, 7.4 kW at 230 V, split across two\n16 A banks each protected by its own single-pole breaker. Balance the load between banks rather than filling\none - the display reports current per bank, so you can do it by reading a number rather than guessing. Metering accuracy is ±5% on amps, which\nis fine for capacity planning and load balancing; it is not a billing-grade meter.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e 2U high, 443.7 mm wide, 112 mm deep, 2.76 kg. Budget two rack units.\nIf you have no rack units to spare and still want metering, the \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e delivers\nthe same 32 A and 7.4 kW as a 0U vertical strip that consumes no rack units at all.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeeding it.\u003c\/strong\u003e A captive 32 A IEC 60309 cord, 12 ft (3.66 m). The rack needs\na 32 A commando socket on a dedicated circuit - a fixed electrical installation, not a wall plug. If that\ncircuit does not exist yet, factor in an electrician, or step down to the 16 A C20-fed metered\n\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e, which keeps both the metering and the C19 outlets.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eManagement.\u003c\/strong\u003e Web, Telnet, SNMP and SSH are built in, with EcoStruxure IT Data Center Expert\nreporting. No network management card purchase is needed. Note that Schneider does not document a\ntemperature\/humidity sensor port on this model, so we do not claim one - if environmental monitoring in the rack\nmatters to you, the 0U \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e does have a sensor port and takes the\n\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat it does not do.\u003c\/strong\u003e No outlet switching - you cannot power-cycle a hung device remotely from\nthis PDU. That is the Switched range: \u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B\u003c\/a\u003e and\n\u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e. And no surge protection - Schneider's specification guide for this\nmodel contains no surge section at all.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Metered and Switched Rack PDU Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSchneider does not publish a package contents list for the AP7822B, so rather than guess we have not listed one. Ask us and we will confirm the current box contents with the distributor before you order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMetered \u0026amp; Switched Rack PDU Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 10 A, 2.3 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C14 inlet, 2.4 m cord supplied\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, 2.4 m cord supplied\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, no cord supplied\u003c\/td\u003e\n\u003ctd\u003e(18) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP7822B (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMetered\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 32 A, 7.4 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCaptive IEC 60309 32 A cord\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(12) C13, (4) C19\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(36) C13, (6) C19\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP7822B. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-5817_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Metered Rack PDU AP7822B - Overview and Specifications (990-5817_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/AP7822B\/apc-netshelter-metered-rack-pdu-2u-1-phase-7-4kw-230v-32a-12-c13-and-4-c19-outlets-iec-309-inlet\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric AP7822B product page (Singapore)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/id\/en\/faqs\/FAQ000277528\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric Rack PDU warranty policy (FAQ000277528)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP7822B\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat does \"Metered\" give me that \"Basic\" does not?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA current meter, a local digital display and a built-in network port. You can see what the rack is drawing, per bank, from the front of the PDU or from your desk over Web or SNMP. A Basic PDU such as the \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552\u003c\/a\u003e just distributes power. Metered does not include remote outlet switching - that is the Switched range.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs it metered per outlet?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. The AP7822B meters aggregate current per bank - two banks, two 16 A breakers - and displays it locally. Per-outlet measurement is a different product class (Metered-by-Outlet). For most capacity planning and load balancing, bank-level metering is what you actually need.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow accurate is the metering?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e±5% on amps, per Schneider's published figure. That is good enough to balance banks, track growth and stay clear of the breaker limit. It is not a revenue-grade meter and should not be used for tenant billing.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDo I need to buy a network management card?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Web, Telnet, SNMP and SSH access are built into the AP7822B, along with EcoStruxure IT Data Center Expert reporting. The AP9640 and AP9641 cards in our catalogue are for Smart-UPS units, not for this PDU.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat input circuit does it need?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA 32 A IEC 60309 commando socket on a dedicated circuit. The 12 ft cord is captive. This is a fixed electrical installation - if your rack has only a 16 A C20 supply available, the metered \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e is the right step down, since it keeps the metering and the C19 outlets. Add a switched \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e as well if you also want remote outlet control.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider's specification guide for the AP7822B contains no surge section, joule rating or clamping figure. Surge suppression is not something this PDU does - put a UPS upstream if you need it.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does it compare with the AP8853?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSame capacity class - both 32 A, 7.4 kW, metered, with built-in network management. The AP7822B is a 2U horizontal unit with sixteen outlets (12 C13, 4 C19). The \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e is a 1,791 mm 0U vertical strip with forty-two outlets (36 C13, 6 C19), an interactive LCD and an environmental sensor port. Choose the AP8853 for a densely populated full-height rack; the AP7822B where a horizontal unit suits the cabinet better.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Metered Rack PDU AP7822B sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the AP7822B with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879312171172,"sku":"AP7822B","price":1275.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_a6cf6823-969a-4f10-82dd-a8fd98776600.jpg?v=1789718951"},{"product_id":"apc-rack-pdu-basic-1u-16a-208-230v-12c13","title":"APC Rack PDU. Basic. 1U. 16A. 208\/230V. (12)C13","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Basic Rack PDU, 1U, 1 Phase, 3.7kW 230V 16A, (12) C13 Outlets, C20 Cord (AP9565) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTwelve C13 Outlets in One Rack Unit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Basic Rack PDU AP9565 puts twelve IEC C13 outlets into a single 1U chassis - enough to power a full cabinet of switches, routers, appliances and 1U servers from one strip. Every outlet is C13, so if your equipment is all C14-corded (and most rack equipment is), this is the straightforward, economical choice.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e3.7 kW at Singapore's 230 V Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSchneider rates the AP9565 at 3.7 kW on a 230 V 16 A supply, or 3.3 kW at 208 V. On Singapore's 230 V, 50 Hz network that is the full 3.7 kW - ample for a comms cabinet or a lightly loaded server rack.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFed by a C20 Cord, Not a Locking Twist Plug\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe input is an IEC 60320 C20 inlet on a 2.5 m cord - Schneider's own product name ends \"C20 cord\". An L6-20P twist-lock plug is sometimes quoted for this part in third-party data; that belongs to the US-market siblings of this PDU, not to this part number.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eShallow, Light and Easy to Retrofit\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAt 44 x 447 x 57 mm and 2.05 kg the AP9565 slides into any 19-inch rack, including shallow wall-mount comms cabinets where a 1.6 m 0U strip simply will not fit. Rack mounting brackets and the installation guide are in the box. There is no meter, display or network port - this is a Basic PDU, and the simplicity is the point.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP9565 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Basic Rack PDU, 1U, 1 phase, 3.7 kW 230 V 16 A or 3.3 kW 208 V 16 A, 12 C13 outlets, C20 cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP9565\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBasic Rack Power Distribution Unit (PDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e1U, 19-inch horizontal rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C20 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e2.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e200 V, 208 V, 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Rating\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacity\u003c\/td\u003e\n\u003ctd\u003e3,680 VA - 3.7 kW at 230 V \/ 16 A, or 3.3 kW at 208 V \/ 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eTwelve (12) IEC 60320 C13 - no C19 outlets on this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMetering, Switching \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eNone - this is a Basic PDU with no meter and no local display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eNone - there is no network port on this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd\u003eNone - outlets are always live when the PDU is powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided - no surge suppression is specified for this product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e44 x 447 x 57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3.64 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE and VDE are stated consistently across Schneider documentation for this model. The current Schneider characteristics sheet additionally lists UL Listed and cUL Listed against UL 60950, while an older APC-format sheet lists CE only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e731304213055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Load Planning\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Twelve IEC C13 outlets, each taking a standard C14 equipment cord.\nThat covers switches, routers, firewalls, NAS and SAN heads, KVMs and the great majority of 1U and 2U servers.\nThere are \u003cem\u003eno\u003c\/em\u003e C19 outlets on this model - if anything in your rack has a 16 A C20 inlet, you need\nthe \u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559\u003c\/a\u003e (ten C13 plus two C19) or a larger model instead. Do not adapt a\n16 A device down onto a 10 A C13 outlet.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLoad planning.\u003c\/strong\u003e 16 A giving 3.7 kW at 230 V. Twelve outlets is a generous\ncount for that capacity, so current, not sockets, is your limit - total the nameplate figures before you commit,\nand leave room for the inrush when a full cabinet powers up together. With no meter on board, measure upstream\nat the UPS if you want ongoing visibility.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e 1U, 447 mm wide, 57 mm deep, 2.05 kg. Shallow enough for wall-mount\nand short comms cabinets and light enough to retrofit into a rack that is already cabled. Rack mounting brackets\nare supplied; there is no toolless mounting kit, which is a 0U accessory.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeeding it.\u003c\/strong\u003e An IEC C20 inlet with a 2.5 m cord supplied - Schneider's own product name\nfor this part ends \"C20 cord\", so there is nothing extra to buy on the input side. A 16 A circuit\nor a 16 A outlet on a UPS is the sensible upstream arrangement. This model does \u003cem\u003enot\u003c\/em\u003e use an L6-20P\ntwist-lock plug - that belongs to the US-market variants of this PDU, not to this part number.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eManagement and monitoring.\u003c\/strong\u003e None on this model. No meter, no LCD, no network port, no outlet\nswitching and no surge protection. Schneider publishes none of those fields for the AP9565. For remote\nmonitoring choose a metered\nmodel such as the \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e; for remote reboot, the switched\n\u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Basic Rack PDU Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC NetShelter Basic Rack PDU (AP9565) with 2.5 m IEC C20 input cord\u003c\/li\u003e\n\u003cli\u003eRack mounting brackets\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eBasic Rack PDU Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP9565 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 16 A, 3,680 VA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC C20 inlet, 2.5 m cord supplied\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(12) C13\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3,680 VA\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, 2.5 m cord supplied\u003c\/td\u003e\n\u003ctd\u003e(10) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3,680 VA\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, cord to be confirmed\u003c\/td\u003e\n\u003ctd\u003e(20) C13, (4) C19\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-32a-230v-ap7553\"\u003eAP7553\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7,400 VA\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(20) C13, (4) C19\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP9565. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-7213_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Rack PDU AP9559 \/ AP9565 - Installation, Operation and Specifications (990-7213_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/in\/en\/product\/AP9565\/apc-netshelter-basic-rack-pdu-1u-1-phase-3-7kw-230v-16a-or-3-3kw-208v-16a-12-c13-outlets-c20-cord\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric AP9565 product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/id\/en\/faqs\/FAQ000277528\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric Rack PDU warranty policy (FAQ000277528)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP9565\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes the AP9565 use an L6-20P plug?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. The input is an IEC 60320 C20 inlet on a 2.5 m cord - Schneider's own product name for this part ends \"C20 cord\", and both current data sheets say the same. L6-20P and L6-30P twist-lock inputs belong to the US-market siblings in this family, and are sometimes quoted against this part number in error.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow much load can it carry?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e16 A - 3.7 kW on a 230 V Singapore supply, or 3.3 kW at 208 V. Twelve outlets share that single 16 A budget, so add up your equipment's nameplate current rather than counting sockets.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAre there any C19 outlets?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo - all twelve outlets are C13. If you have a device with a 16 A C20 inlet, this is the wrong model: the \u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559\u003c\/a\u003e is the same 1U chassis with ten C13 and two C19 outlets, and the larger 0U models offer more.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. No Schneider document for the AP9565 contains a surge rating, joule figure or clamping specification. Descriptions claiming \"basic surge protection\" for this part are not supported by Schneider. Surge protection is a UPS function.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan I see how much power the rack is drawing?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNot from this PDU - it is a Basic model with no meter and no network port. If per-rack visibility matters, the metered \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e adds unit-level metering and a built-in network port; the switched \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e adds remote per-outlet control on top.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWill it fit a wall-mount comms cabinet?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes - 1U high and only 57 mm deep, so it fits shallow wall-mount enclosures where a 0U strip cannot. That is the practical reason most Singapore SME sites choose a 1U PDU over a 0U one.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Basic Rack PDU AP9565 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the AP9565 with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879313907876,"sku":"AP9565","price":267.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_1abd80d2-d4aa-4d8a-9637-48f5542ea230.jpg?v=1789719031"},{"product_id":"apc-power-cord-kit","title":"APC Power Cord Kit (6 ea). Locking. C13 to C14. 1.2m","description":"\u003ch2\u003e\u003cstrong\u003eAPC Power Cord Kit (6 ea). Locking. C13 to C14. 1.2m (AP8704S-WW) - 1 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eSecure, Locking Power Connections\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC Power Cord Kit (AP8704S-WW) includes six locking C13 to C14 power cords designed to keep critical connections firmly in place. The locking mechanism prevents accidental disconnection from vibration, cable bumps, or maintenance work, delivering reliable power in high-traffic data center and industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOptimal 1.2m Cable Length\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEach cord measures 1.2 meters, providing the flexibility to route power neatly between equipment and PDUs or UPS systems. The convenient length supports tidy cable management within IT racks while ensuring devices stay reliably powered without strain on connectors.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDurable, Professional-Grade Construction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBuilt with high-quality PVC-insulated cable rated for 250V AC and 10A, these cords are made to withstand daily use in demanding environments. The sturdy build ensures dependable power delivery and reduces the risk of downtime caused by failing or loose connections.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEasy Installation and Broad Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInstallation is quick: plug the locking C13 connector into your device and the C14 connector into the power source for an instantly secure link. The kit is compatible with servers, network equipment, and UPS systems requiring C13 to C14 connections, making it a versatile choice for rack deployments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Power Cord Kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length\u003c\/strong\u003e: 1.2 meters (4 feet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity\u003c\/strong\u003e: 6 cords per kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Type 1\u003c\/strong\u003e: Locking C13 (female)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Type 2\u003c\/strong\u003e: C14 (male)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking Mechanism\u003c\/strong\u003e: Yes, locking feature for secure connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Type\u003c\/strong\u003e: Standard power cable with locking connectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: 250V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e: 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e: UL; CE; RoHS compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Compatible with servers, network equipment, and UPS systems requiring C13 to C14 connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsage\u003c\/strong\u003e: Ideal for use in data centers, IT racks, and other environments requiring secure power connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor\u003c\/strong\u003e: Black\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial\u003c\/strong\u003e: PVC (Polyvinyl Chloride) insulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeatures\u003c\/strong\u003e: Locking connectors to prevent accidental unplugging; high-quality construction for durable and safe power delivery; designed for use in professional environments like data centers and server racks; ensures reliable power connections for sensitive equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e: Operating Temperature 0°C to 70°C (32°F to 158°F); Humidity 0% to 95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal Use Case:\u003c\/strong\u003e Ideal for data centers and IT racks that need secure, locking C13 to C14 power connections between servers, network gear, and PDUs or UPS systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGTIN\/UPC:\u003c\/strong\u003e 731304267978\u003c\/p\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879315447972,"sku":"AP8704S-WW","price":155.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-power-cord-kit-6-ea-locking-c13-to-c14-12m-1-years-local-warranty-533896.jpg?v=1654153894"},{"product_id":"apc-temperature-humidity-sensor","title":"APC Temperature \u0026 Humidity Sensor","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Temperature \u0026amp; Humidity Sensor, RJ45, 3.9 m Lead (AP9335TH) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eRack Temperature and Humidity, Reported Through Equipment You Already Own\u003c\/h3\u003e\n\u003cp\u003eThe APC Temperature \u0026amp; Humidity Sensor (AP9335TH) measures temperature and relative humidity in a data centre, server room or network closet and reports through an APC host device - a NetBotz appliance, or a Network Management Card 3 with environmental monitoring capability, both of which put the readings on your network.\u003c\/p\u003e\n\u003cp\u003eIt connects with a standard RJ45 lead 3.9 m long, so the sensor head can sit at the point that actually matters - the top of the rack, the cold aisle inlet, the shelf where the switch stack runs hottest - rather than wherever the host device happens to be mounted.\u003c\/p\u003e\n\u003ch3\u003eHumidity Is Not an Optional Reading in Singapore\u003c\/h3\u003e\n\u003cp\u003eTemperature alarms are the ones people fit. Humidity is the one that quietly does damage. Singapore's ambient relative humidity sits high year-round, and a comms cabinet that loses cooling accumulates moisture as well as heat. Sustained high humidity corrodes contacts and connectors and shortens sealed lead-acid battery life; very low humidity, in an over-dried computer room, raises static risk.\u003c\/p\u003e\n\u003cp\u003eMeasuring both from one sensor, with thresholds and alerting handled by a networked host - a Network Management Card 3 with environmental monitoring, or a NetBotz appliance - turns an invisible risk into an e-mail.\u003c\/p\u003e\n\u003ch3\u003ePlugs Into the AP9641, the AP9613 or a NetBotz Appliance\u003c\/h3\u003e\n\u003cp\u003eSchneider lists the AP9335TH as compatible with NetBotz appliances and with an NMC3 that has environmental monitoring capability - that is the AP9641. It also connects to the universal I\/O ports on the AP9613 Dry Contact I\/O SmartSlot Card, and to the universal sensor ports on the NetBotz Rack Monitor 250.\u003c\/p\u003e\n\u003cp\u003eIt will not work with the AP9640, which has no universal I\/O ports. If you are buying a management card and a sensor together, specify the AP9641.\u003c\/p\u003e\n\u003ch3\u003eA Small Purchase That Closes a Real Monitoring Gap\u003c\/h3\u003e\n\u003cp\u003eMost SME server rooms in Singapore monitor the UPS and nothing else in the rack. Adding a sensor to an existing card costs little, needs no new management platform when the host card or appliance is already on the network, and gives you an early warning on the failure mode that most often takes out a comms cabinet over a public holiday.\u003c\/p\u003e\n\u003cp\u003eStocked and invoiced locally in Singapore with GST.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP9335TH Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP9335TH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Temperature \u0026amp; Humidity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eMeasures temperature and humidity in a data centre or network closet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReports Through\u003c\/td\u003e\n\u003ctd\u003eNetBotz appliances, or an NMC3 with environmental monitoring capability (AP9641). The AP9613 Dry Contact I\/O Card also accepts the sensor on its universal I\/O ports.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric) - standard hardware warranty for repair or replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eYes - supplied and supported locally by SourceIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFunction \u0026amp; Connectivity\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasured Values\u003c\/td\u003e\n\u003ctd\u003eTemperature and relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3.9 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Devices - Cards\u003c\/td\u003e\n\u003ctd\u003eAP9641 (universal I\/O ports); AP9613 Dry Contact I\/O Card (universal I\/O ports 1 and 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Devices - Appliances\u003c\/td\u003e\n\u003ctd\u003eNetBotz appliances including the NetBotz Rack Monitor 250 (NBRK0250A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNot Compatible With\u003c\/td\u003e\n\u003ctd\u003eAP9640 - that card has no universal I\/O ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlerting\u003c\/td\u003e\n\u003ctd\u003eThresholds, e-mail, SNMP traps and logging are handled by a networked host - the AP9641 or a NetBotz appliance. The AP9613 is a dry contact signalling card with no network interface, so it cannot send network alerts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions and Net Weight\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this part - ask SourceIT if you need a figure for a mounting plan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003eNot published in the AP9335TH product documentation - ask SourceIT if a stated tolerance is required for your application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature and Humidity Range\u003c\/td\u003e\n\u003ctd\u003eNot published in the AP9335TH product documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat the AP9335TH plugs into.\u003c\/strong\u003e It is a sensor, not a standalone monitor - it always reports through a host device. Schneider lists compatibility with NetBotz appliances and with an NMC3 that has environmental monitoring capability.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNMC3 with Environmental Monitoring - 2 universal I\/O ports. This is the card to pair the sensor with.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-dry-contact-i-o-smartslot-card-ap9613\"\u003eAP9613\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eDry Contact I\/O SmartSlot Card - universal I\/O ports 1 and 2 accept the AP9335TH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNBRK0250A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNetBotz Rack Monitor 250 - 6 universal sensor ports, supports up to 42 wired sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-ap9640\"\u003eAP9640\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eNot compatible\u003c\/strong\u003e - the AP9640 has no universal I\/O ports. Specify the AP9641 instead.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eCable reach.\u003c\/strong\u003e The lead is 3.9 m, terminated RJ45. That is enough to run from a card in a UPS at the bottom of a rack to a sensing point at the top of the same rack, or across to an adjacent cabinet. It is not enough to cross a room - for wider coverage, use a NetBotz appliance with several sensors rather than one long run.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many can I connect?\u003c\/strong\u003e Two per AP9641 or AP9613 (they have two universal I\/O ports each). Six directly on a NetBotz Rack Monitor 250, which supports up to 42 wired sensors in total using its A-Link ports.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack PDU sensor ports.\u003c\/strong\u003e Schneider's published compatibility for the AP9335TH names NetBotz appliances and NMC3 cards with environmental monitoring. If you want environmental sensing on a specific Rack PDU model, ask SourceIT to confirm the supported sensor part number for that unit rather than assuming this one fits.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; APC Environmental Sensor Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eIn the box.\u003c\/strong\u003e Schneider Electric does not publish a package contents list for the AP9335TH that we can verify, so we do not reproduce one here. The sensor has a 3.9 m RJ45 lead. SourceIT will confirm the contents before you order.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHost devices for this sensor, in the SourceIT catalogue\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSensor capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 universal I\/O ports; ships with an AP9335T temperature sensor already included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-dry-contact-i-o-smartslot-card-ap9613\"\u003eAP9613\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 universal I\/O ports, plus 4 dry contact inputs and 6 output relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNBRK0250A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 universal sensor ports; up to 42 wired and 47 wireless sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRelated sensors and accessories\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP9335TH (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature and humidity, RJ45, 3.9 m lead\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335T\u003c\/td\u003e\n\u003ctd\u003eTemperature only - not a stocked SourceIT line, available to order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9810\u003c\/td\u003e\n\u003ctd\u003eDry contact I\/O accessory for AP9613 and AP9641 universal I\/O ports - not stocked, available to order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRacks and enclosures\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-6u-low-profile-wallmount-rack-enclosure-ar106vi\"\u003eAR106VI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNetShelter 6U low-profile wallmount enclosure, 230 V fans - a common home for a sensor of this kind\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP9335TH. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/AP9335TH\/apc-temperature-humidity-sensor\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page (Singapore) - APC Temperature \u0026amp; Humidity Sensor AP9335TH\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/iportal.se.com\/Contents\/docs\/UPS%20NETWORK%20MANAGEMENT%20CARD%203_USER%20GUIDE.PDF\" target=\"_blank\" rel=\"noopener\"\u003eUPS Network Management Card 3 user guide (PDF) - covers sensor connection to the AP9641\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed a specific document, a compliance declaration or a written quotation? Contact SourceIT and we will supply it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP9335TH\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWill the AP9335TH work with any APC network management card?\u003c\/h4\u003e\n\u003cp\u003eNo. It needs universal I\/O ports, which the \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641\u003c\/a\u003e has and the \u003ca href=\"\/products\/apc-ups-network-management-card-3-ap9640\"\u003eAP9640\u003c\/a\u003e does not. Schneider's own description of the sensor names NetBotz appliances and an NMC3 with environmental monitoring capability. If you are ordering a card and sensor together, order the AP9641.\u003c\/p\u003e\n\u003ch4\u003eWhat does the \"TH\" in AP9335TH mean?\u003c\/h4\u003e\n\u003cp\u003eTemperature and Humidity. The AP9335T without the H is the temperature-only version of the same sensor. They are different part numbers and different products - the T is the one that ships in the box with an AP9641, and the TH is the one you add when you want humidity as well.\u003c\/p\u003e\n\u003ch4\u003eHow long is the cable?\u003c\/h4\u003e\n\u003cp\u003e3.9 m, terminated RJ45. That is enough to run from a management card in a UPS at the bottom of a rack to a sensing point at the top, or into the adjacent cabinet. For coverage across a room, use a NetBotz appliance with multiple sensors rather than one long cable run.\u003c\/p\u003e\n\u003ch4\u003eHow many sensors can I connect?\u003c\/h4\u003e\n\u003cp\u003eTwo per AP9641 or AP9613, since each card has two universal I\/O ports. A \u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNetBotz Rack Monitor 250\u003c\/a\u003e has six universal sensor ports directly and supports up to 42 wired sensors in total.\u003c\/p\u003e\n\u003ch4\u003eDoes the sensor send the alerts itself?\u003c\/h4\u003e\n\u003cp\u003eNo - the host device does. Thresholds, e-mail notification, SNMP traps and logging are all configured on the network management card or NetBotz appliance the sensor plugs into, and the sensor supplies the readings. Note that the AP9613 Dry Contact I\/O Card also accepts this sensor but has no network interface of its own, so it cannot send network alerts.\u003c\/p\u003e\n\u003ch4\u003eWhy monitor humidity and not just temperature?\u003c\/h4\u003e\n\u003cp\u003eBecause in Singapore's climate humidity is the slower, less visible failure mode. Sustained high relative humidity in an unconditioned comms cabinet corrodes connectors and shortens sealed lead-acid battery life, and a cabinet that has lost cooling gains moisture as well as heat. Temperature tells you about today; humidity tells you why the hardware aged faster than expected.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC AP9335TH sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the AP9335TH with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879316365476,"sku":"AP9335TH","price":265.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_1383e95e-8b5b-4ed7-bb65-8948bfcb05e1.jpg?v=1789719055"},{"product_id":"apc-back-ups-pro-br-650va","title":"APC Back UPS Pro BR 650VA, 6 Outlets, AVR, LCD Interface","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Back UPS Pro BR 650VA, 6 Outlets, AVR, LCD Interface (BR650MI) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eAPC BR650MI 650 VA \/ 390 W UPS for Singapore's 230V \/ 50Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC BR650MI is a 650 VA \/ 390 W line-interactive UPS with stepped-approximation output, built for 230 V, 50 Hz supplies — exactly what Singapore's PUB grid delivers. It rides through the short dips, brownouts and momentary interruptions that follow an afternoon thunderstorm, and its Automatic Voltage Regulation corrects high and low mains voltage \u003cem\u003ewithout\u003c\/em\u003e going to battery, so the cells are not cycled every time the supply wanders. Output is 6 x C13, all battery-backed.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStepped-Approximation Output — Check Your PSU Before You Order\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BR650MI produces a stepped approximation to a sinewave on battery, which is what the Schneider data sheet states for this exact part number. That is entirely suitable for most desktop PCs, routers, switches, NVRs, POS terminals and comms-cabinet gear. If the load is an active-PFC ATX power supply that is fussy about waveform, specify a sine wave model instead — in the Back-UPS Pro BR range that is the \u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e or \u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e. We would rather tell you that up front than take the return.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutlets, Runtime and Battery Life in a Humid Climate\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOutlets are 6 x IEC 60320 C13 (battery backup and surge protection). The battery is a sealed maintenance-free lead-acid (VRLA) cartridge with a 3 to 5 year expected service life. Singapore's heat and humidity are hard on VRLA cells, so plan on a cartridge change inside that window rather than at the end of it; the replacement part is \u003ca href=\"\/products\/apc-replacement-battery-cartridge-110-apcrbc110\"\u003eAPCRBC110\u003c\/a\u003e. Schneider does not publish a runtime-versus-load table for the BR650MI, so we do not print one — runtime depends entirely on how much of the 390 W you actually draw. Tell us your load in watts and we will size it for you.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSME Office, Home Office and Comms-Cabinet Duty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis is a tower unit at 190 mm (H) x 91 mm (W) x 310 mm (D), 6.4 kg — it sits on a desk, under a counter or on the floor of a comms cupboard rather than in a rack, so it costs you no rack U. Everything SourceIT ships is local Singapore stock with a GST invoice and local warranty support — no grey imports, no chasing an overseas RMA.\u003c\/p\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC BR650MI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eEvery figure below is taken from the Schneider Electric product page (Singapore) and the APC BR650MI product data sheet, corroborated by the official Back-UPS Pro 230V brochure. Where Schneider does not publish a value for this exact part number, the row is left out rather than filled in from a similar model.\u003c\/p\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eBR650MI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro, 650VA\/390W, Tower, 230V, 6x IEC C13 outlets, AVR, LCD, User Replaceable Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro BR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive with Automatic Voltage Regulation (AVR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e650 VA \/ 390 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003eRepair or replace; Schneider states 2 years for the rest of the world and 3 years inside the European Community, so Singapore takes the 2-year term\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupported locally by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e390 W \/ 650 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 1 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform (on battery)\u003c\/td\u003e\n\u003ctd\u003eStepped approximation to a sinewave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003e6 x IEC 60320 C13 (battery backup and surge protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e10 ms typical, 12 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Filtering\u003c\/td\u003e\n\u003ctd\u003eFull-time multi-pole noise filtering, 10% of IEEE surge let-through, instantaneous response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e176 to 294 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 3 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e10 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003eAutomatic Voltage Regulation (AVR) — corrects high and low mains voltage without switching to battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed maintenance-free lead-acid (VRLA), user replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e7.0 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Rating\u003c\/td\u003e\n\u003ctd\u003e75 VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e12 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Battery Life\u003c\/td\u003e\n\u003ctd\u003e3 to 5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Runtime\u003c\/td\u003e\n\u003ctd\u003eNo external battery pack is documented for this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Load\u003c\/td\u003e\n\u003ctd\u003eSchneider publishes no runtime-versus-load figures for this model — contact SourceIT with your load in watts for a sizing calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Interface\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Alarms\u003c\/td\u003e\n\u003ctd\u003eAlarm when on battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eNot available on this model — there is no SmartSlot for an internal network management card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e190 mm (H) x 91 mm (W) x 310 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e6.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Mountable\u003c\/td\u003e\n\u003ctd\u003eNo — tower form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-15 to 45 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e45 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, RCM, C-Tick, A-Tick, EAC, TISI, GS Mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe BR650MI presents 6 x C13, all battery-backed. All outlets are IEC 60320 C13, so a standard C13 kettle lead connects a PC, monitor, switch, router or NAS directly. Every outlet on this model is battery-backed and surge protected. The unit takes its own supply through an IEC 60320 C14 inlet on a normal 13 A Singapore wall socket — no dedicated circuit and no electrician needed.\u003c\/p\u003e\n\u003ch4\u003eSizing it: VA, watts and how much you can actually load\u003c\/h4\u003e\n\u003cp\u003eThe BR650MI is rated 650 VA apparent power and 390 W real power. Size against the \u003cstrong\u003ewatts\u003c\/strong\u003e, not the VA — the watt figure is the one that runs out first on modern IT loads. As a working rule, keep the connected load under about 70% of 390 W so you have headroom for inrush and for the battery ageing. Schneider publishes no runtime table for this model, so any minutes figure you see quoted elsewhere is someone's estimate, not a manufacturer specification. Send us your equipment list and we will work out the real number.\u003c\/p\u003e\n\u003ch4\u003eBattery and replacement cartridge\u003c\/h4\u003e\n\u003cp\u003eThe battery is a sealed maintenance-free lead-acid (VRLA) cartridge, 12 V 7.0 Ah. Typical recharge time is 12 h. The APC replacement cartridge for this model is \u003cstrong\u003eAPCRBC110\u003c\/strong\u003e — \u003ca href=\"\/products\/apc-replacement-battery-cartridge-110-apcrbc110\"\u003eAPCRBC110\u003c\/a\u003e is stocked by SourceIT. The cartridge is user-replaceable from the front of the unit; APC does not describe this model's battery as swappable while running, so plan a short shutdown for the change.\u003c\/p\u003e\n\u003ch4\u003eRack space and management software\u003c\/h4\u003e\n\u003cp\u003eThis is a tower unit and is not rack mountable, so it consumes no rack U and needs no rail kit. This model has no SmartSlot, so an AP9640 or AP9641 Network Management Card cannot be fitted — if you need SNMP monitoring or an Ethernet-managed UPS, step up to the APC Smart-UPS range and we will quote it. Bundled shutdown software is not documented for this model in the Schneider material we can verify, so we do not claim it; ask us and we will confirm what ships in the current carton.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Back-UPS Pro BR Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cp\u003eSchneider does not itemise the carton contents for this model in the documentation we can verify, so we will not invent a list. What we can tell you is that the unit ships as a complete tower UPS with its battery installed. If the exact carton contents matter for your tender or your install, ask us before you order and we will open a unit and tell you what is actually in it.\u003c\/p\u003e\n\u003ch4\u003eAPC Back-UPS and Back-UPS Pro BR range at SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-500va-300w-tower-230v-br500ci-as\"\u003eBR500CI-AS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS, 500VA \/ 300W tower, 3x C13 — 500 VA \/ 300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBR650MI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBack-UPS Pro, 650VA \/ 390W tower, 6x C13 — 650 VA \/ 390 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-900va\"\u003eBR900MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 900VA \/ 540W tower, 6x C13 — 900 VA \/ 540 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1200VA \/ 720W tower, 8x C13, sine wave, USB A+C — 1200 VA \/ 720 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-1300va\"\u003eBR1300MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1300VA \/ 780W tower, 8x C13 — 1300 VA \/ 780 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1500va-865w-tower-230v-10x-iec-c13-outlets-avr-lcd-br1500gi\"\u003eBR1500GI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1500VA \/ 865W tower, 10x C13, external pack capable — 1500 VA \/ 865 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1600va-960w-tower-230v-br1600mi\"\u003eBR1600MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13 — 1600 VA \/ 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13, sine wave, USB A+C — 1600 VA \/ 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-external-battery-pack-for-1500va-back-ups-pro-models-br24bpg\"\u003eBR24BPG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro external battery pack, 24 V \/ 372 VAh (for BR1500GI) — Battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMatching replacement battery cartridge\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003eAPCRBC110\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for the BR650MI — \u003ca href=\"\/products\/apc-replacement-battery-cartridge-110-apcrbc110\"\u003eAPCRBC110\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003cp\u003eRail kits and network management cards do not apply to this range: every Back-UPS Pro BR model is a tower with no SmartSlot. For rack-mount or network-managed power protection, ask us about the APC Smart-UPS SMT, SMC and SMX ranges.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eLinks open on Schneider Electric's own site. Each one was checked before publication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/BR650MI\/apc-backups-pro-650va-390w-tower-230v-6x-iec-c13-outlets-avr-lcd-user-replaceable-battery\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for the APC BR650MI\u003c\/a\u003e — official product name, characteristics and the full document list (Singapore site)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/SPD_AHUG-B59B4X_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Back-UPS Pro BR650\/900\/1300\/1600MI User Manual (Schneider document library)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's direct datasheet PDF links sit behind a path that blocks automated retrieval, so we link the product page and the document library entry instead — every link above resolves and carries the current document. If you need the datasheet or manual emailed to you as a file for a tender submission, ask us and we will send it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC BR650MI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 650 VA and the 390 W rating?\u003c\/h4\u003e\n\u003cp\u003e650 VA is apparent power and 390 W is real power. Your equipment consumes real power, so the 390 W figure is the one that limits what you can connect. Add up the wattage on the nameplates of everything you intend to back up and keep the total comfortably below 390 W.\u003c\/p\u003e\n\u003ch4\u003eHow long will the BR650MI run my equipment?\u003c\/h4\u003e\n\u003cp\u003eIt depends entirely on load, and Schneider publishes no runtime table for this model — which is why you will not find minutes quoted on this page. A lightly loaded unit runs for many minutes; one near 390 W runs for a few. Send SourceIT your load in watts and we will calculate it against the 75 VAh battery rating rather than guess.\u003c\/p\u003e\n\u003ch4\u003eWhat does the \"MI\" in BR650MI mean?\u003c\/h4\u003e\n\u003cp\u003eIt identifies the build variant. MI is the 230 V IEC-outlet build sold across Asia, the Middle East and Europe, with a stepped-approximation output waveform and no USB charging ports. These suffixes are not interchangeable — outlet counts, waveform and battery cartridge all change with them, so order by the exact part number.\u003c\/p\u003e\n\u003ch4\u003eIs the output a pure sine wave, and will it drive an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eNo. The BR650MI produces a stepped approximation to a sinewave, as stated in its data sheet. That is fine for most desktops, routers, switches, NVRs and POS gear, but some active-PFC ATX power supplies will alarm or drop out on it. If your load has an active-PFC supply, choose the \u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e or \u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e instead — both are sine wave.\u003c\/p\u003e\n\u003ch4\u003eWhich replacement battery does it take, and can I fit it myself?\u003c\/h4\u003e\n\u003cp\u003eThe APC replacement battery cartridge for the BR650MI is \u003cstrong\u003eAPCRBC110\u003c\/strong\u003e, stocked here: \u003ca href=\"\/products\/apc-replacement-battery-cartridge-110-apcrbc110\"\u003eAPCRBC110\u003c\/a\u003e. It is user-replaceable — no tools beyond a screwdriver and no service call. APC does not describe this model's battery as swappable while running, so shut the unit down for the swap. Expect three to five years of service in an air-conditioned office, and less in a hot, humid comms cupboard.\u003c\/p\u003e\n\u003ch4\u003eCan I rack mount it or add a network management card?\u003c\/h4\u003e\n\u003cp\u003eNo on both counts. The BR650MI is a tower unit with no rack ears or rail kit option, and the Back-UPS Pro BR range has no SmartSlot, so an AP9640 or AP9641 card cannot be fitted. If you need a 19-inch rack UPS or SNMP monitoring, ask SourceIT about the APC Smart-UPS SMT, SMC and SMX ranges.\u003c\/p\u003e\n\u003ch4\u003eHow does the BR650MI compare with the BR900MI?\u003c\/h4\u003e\n\u003cp\u003eThe \u003ca href=\"\/products\/apc-back-ups-pro-br-900va\"\u003eBR900MI\u003c\/a\u003e steps up from 650 VA \/ 390 W to 900 VA \/ 540 W on the same 190 x 91 x 310 mm chassis for very little extra footprint. Both are stocked by SourceIT in Singapore — tell us the load and the budget and we will tell you which one is the right buy.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC BR650MI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the BR650MI with a 2-year manufacturer warranty. Note that Schneider states three years inside the European Community and two years elsewhere — Singapore takes the two-year term, and any listing quoting three years for this market has copied the European figure.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/dZ-hRA5gJ48\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879324623012,"sku":"BR650MI","price":285.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_ca681e02-7382-435a-b8a5-61b2caad00fd.jpg?v=1789719091"},{"product_id":"apc-back-ups-625va","title":"APC Back-UPS 625VA, 230V, AVR, Floor, Universal Sockets","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Back-UPS 625VA, 230V, AVR, Floor, Universal Sockets (BX625CI-MS) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eAPC BX625CI-MS — 625 VA \/ 325 W of battery backup and AVR for Singapore's 230 V mains\u003c\/h3\u003e\n\u003cp\u003eThe APC BX625CI-MS is a line-interactive unit rated 625 VA \/ 325 W at 230 V, built for the way Singapore's supply actually behaves. Our grid is reliable but not flat: PUB-fed 230 V \/ 50 Hz mains sags during afternoon storms, and switching events in an older building push the voltage around enough to reboot a desktop or corrupt a file mid-save. Automatic Voltage Regulation corrects those high and low excursions using the transformer rather than the battery, so the unit rides out routine brownouts without spending a charge cycle.\u003c\/p\u003e\n\u003ch3\u003eUniversal sockets that take a Singapore three-pin plug directly\u003c\/h3\u003e\n\u003cp\u003eThis model provides 3 universal outlets, all battery-backed. The universal receptacles accept BS 1363 three-pin plugs as supplied on equipment sold here, alongside the European and North American plug bodies you find on imported kit — so nothing needs an adaptor hanging off the back of it. Surge protection is rated at 273 Joules, absorbing the switching transients and lightning-season spikes that do slow, cumulative damage to power supplies.\u003c\/p\u003e\n\u003ch3\u003eSized for the SME office, the home office and the comms cupboard\u003c\/h3\u003e\n\u003cp\u003eAt 279 mm (H) x 160 mm (W) x 89 mm (D) and 5.0 kg this is a unit you put under a desk, beside a router or inside a small comms cabinet and then forget about. It is a tower, designed to live on the floor or on a shelf. It is rated for 0 to 40 °C ambient with a relative humidity range of 0 to 95 % non-condensing — worth noting, because ambient heat and humidity are what shorten a sealed lead-acid battery's life here far more than the number of power cuts it sees. Keep it in the conditioned part of the room and you will get the full three to five years out of the battery.\u003c\/p\u003e\n\u003ch3\u003eBought locally, invoiced locally, supported locally\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the BX625CI-MS as the ASEAN -MS build, which is the correct specification for Singapore, with a GST invoice and local warranty support. That matters on power protection more than on most categories: a UPS bought grey has no practical warranty path here, and by the time it fails you are dealing with the battery, not the electronics. If you are protecting more than a single desk, send us the equipment list and we will size the whole set for you rather than sell you the model whose number looks closest.\u003c\/p\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC BX625CI-MS Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eBX625CI-MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Schneider Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS, 625VA, Floor, 230V, 3 Universal outlets, AVR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS BX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive with Automatic Voltage Regulation (AVR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eFloor-standing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Capacity\u003c\/td\u003e\n\u003ctd\u003e625 VA \/ 325 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupplied and warranted locally by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOutput\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e625 VA \/ 325 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform on Battery\u003c\/td\u003e\n\u003ctd\u003eSquare wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlets\u003c\/td\u003e\n\u003ctd\u003e3 universal receptacles, all with battery backup and surge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e273 Joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Voltage Regulation\u003c\/td\u003e\n\u003ctd\u003eYes — AVR corrects high and low mains voltage without drawing on the battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInput\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e151 to 299 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e45 to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBatteries \u0026amp; Runtime\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed lead-acid with suspended electrolyte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCommunications \u0026amp; Management\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eLED status display showing on-line and on-battery conditions\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e279 mm (H) x 160 mm (W) x 89 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e5.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e45 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications we do not publish for this model\u003c\/h3\u003e\n\u003cp\u003eSourceIT lists only figures confirmed by Schneider Electric's own documentation for this exact part number. The following are deliberately absent rather than unknown to us:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTransfer time and output frequency — printed in only one of the two data sheet mirrors reached.\u003c\/li\u003e\n\u003cli\u003eCertification list — single source only.\u003c\/li\u003e\n\u003cli\u003eBattery voltage and amp-hour capacity — not published for this model.\u003c\/li\u003e\n\u003cli\u003eRuntime at load — Schneider publishes no runtime table for this model.\u003c\/li\u003e\n\u003cli\u003eInput plug type and cord length — the data sheet contradicts itself (input connection IEC-320 C14, package contents a NEMA 5-15P cord), so neither figure is published here.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf a missing figure matters to your specification, ask us and we will confirm it with the distributor rather than guess.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat you can plug into it\u003c\/h3\u003e\n\u003cp\u003eThe BX625CI-MS provides 3 universal outlets, all battery-backed. Universal receptacles accept Singapore BS 1363 three-pin plugs as well as the common European and North American plug bodies, so a mixed desk of local kit and imported equipment plugs straight in without adaptors. Size the load in watts, not in the number of free sockets: this model is rated at 325 W of real power and that figure, not the socket count, is the limit.\u003c\/p\u003e\n\u003cp\u003eSurge protection is rated at 273 Joules. That covers the switching transients and lightning-season spikes that a Singapore office sees on a 230 V supply; it is not a substitute for a properly earthed circuit.\u003c\/p\u003e\n\u003ch3\u003eRuntime\u003c\/h3\u003e\n\u003cp\u003eSchneider Electric does not publish a runtime table for this model, so SourceIT does not print one. Runtime depends entirely on the connected load. Tell us what you intend to plug in and we will size it against the published wattage rather than quote you a number we cannot source.\u003c\/p\u003e\n\u003cp\u003eRecharge from a full discharge takes about 6 hours, so a unit that has ridden out a long outage will not deliver full backup again immediately.\u003c\/p\u003e\n\u003ch3\u003eBattery replacement\u003c\/h3\u003e\n\u003cp\u003eThe battery in this unit is user-replaceable and the correct APC replacement cartridge is \u003cstrong\u003eAPCRBC110\u003c\/strong\u003e, which SourceIT stocks: \u003ca href=\"\/products\/apc-replacement-battery-cartridge-110-apcrbc110\"\u003eAPC Replacement Battery Cartridge APCRBC110\u003c\/a\u003e. A sealed lead-acid battery in a Singapore office typically wants replacing every three to five years; heat and humidity shorten that, air-conditioned comms rooms extend it. Replacing the cartridge is far cheaper than replacing the UPS.\u003c\/p\u003e\n\u003ch3\u003eManagement, software and monitoring\u003c\/h3\u003e\n\u003cp\u003eNo communication port is listed in the Schneider specification for this build, so SourceIT makes no shutdown-software or network-management claim for it. If unattended server shutdown or SNMP monitoring is a requirement, the APC Smart-UPS SMT and SMC ranges are the right place to look — ask us and we will compare them against your load.\u003c\/p\u003e\n\u003ch3\u003eSiting it\u003c\/h3\u003e\n\u003cp\u003eFootprint is 279 mm (H) x 160 mm (W) x 89 mm (D) at 5.0 kg, and the unit is rated for 0 to 40 °C ambient with a relative humidity range of 0 to 95 % non-condensing. It is a floor-standing or under-desk tower. Battery life is temperature-driven, so keep it out of direct sun and away from the warm side of a rack.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Back-UPS BX Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the box\u003c\/h3\u003e\n\u003cp\u003eUPS unit, detachable input power cord, user manual.\u003c\/p\u003e\n\u003ch3\u003eAPC Back-UPS BX range at SourceIT\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCapacity and outlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBX625CI-MS (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e625 VA \/ 325 W — 3 universal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-750va-230v-avr-universal-sockets-bx750mi-ms\"\u003eBX750MI-MS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e750 VA \/ 410 W — 2 universal + 1 C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-950va-230v-avr-bx950mi-ms\"\u003eBX950MI-MS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e950 VA \/ 520 W — 2 universal + 2 C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-1200va-230v-avr-universal-sockets-bx1200mi-ms\"\u003eBX1200MI-MS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 VA \/ 650 W — 4 universal + 1 C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-1600va-230v-avr-universal-sockets-bx1600mi-ms\"\u003eBX1600MI-MS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1600 VA \/ 900 W — 4 universal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-2200va-230v-avr-bx2200mi-ms\"\u003eBX2200MI-MS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2200 VA \/ 1200 W — 4 universal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eReplacement battery cartridges\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-110-apcrbc110\"\u003eAPCRBC110\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCorrect APC replacement cartridge for the BX625CI-MS\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch3\u003eWhat this range does not take\u003c\/h3\u003e\n\u003cp\u003eThe APC Back-UPS BX range is a self-contained UPS. It has no SmartSlot, no external battery pack option and no rail kit — the battery inside it is the only battery, and extending runtime means moving up the range or moving to an APC Smart-UPS. If you need a rack-mounted unit, an internal network management card or an external battery pack, ask us about the Smart-UPS SMT, SMC and SMX families instead.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/BX625CI-MS\/apc-backups-625va-floor-230v-3-universal-outlets-avr\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for the BX625CI-MS\u003c\/a\u003e — official product identity, feature list and document library (Singapore site)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/download\/document\/SPD_AHUG-97RDHC_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Back-UPS BX625CI-MS — User Manual (SPD_AHUG-97RDHC_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEach link above was checked and resolved at the time this page was written. Schneider's own canonical datasheet download path blocks automated retrieval, so we link the product page and document library entries that do open rather than a URL that will fail for you. If you need the PDF datasheet attached to a quotation or a tender submission, email us and we will send it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC BX625CI-MS\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eHow do I size the BX625CI-MS — is VA or W the number that matters?\u003c\/h3\u003e\n\u003cp\u003eWatts. The BX625CI-MS is rated 625 VA apparent power and \u003cstrong\u003e325 W\u003c\/strong\u003e real power, and it is the watt figure that limits what you can connect. Add up the wattage on the nameplates of everything you want backed up, then leave headroom — a UPS run at its ceiling gives you the shortest possible runtime and works its battery hardest. As a rule of thumb, aim to load it to about half its watt rating for comfortable backup.\u003c\/p\u003e\n\u003ch3\u003eHow long will it run in a power cut?\u003c\/h3\u003e\n\u003cp\u003eSchneider Electric publishes no runtime table for this model, so we do not print one. Anyone quoting you an exact minute figure for it is guessing.\u003c\/p\u003e\n\u003cp\u003eRuntime on any UPS of this class is measured in minutes, not hours. The purpose is to ride through the short dips and brief outages that are the common failure mode on Singapore's grid, and to give you time for a clean shutdown on a longer one — not to keep you working through an extended blackout. Tell us your actual load and we will size it with you.\u003c\/p\u003e\n\u003ch3\u003eWhat does the “-MS” suffix in BX625CI-MS mean?\u003c\/h3\u003e\n\u003cp\u003eIt identifies the ASEAN regional build, supplied with universal receptacles that accept Singapore BS 1363 plugs directly. It is a genuinely different build from the European “-GR” (Schuko), the UK “-UK” and the plain IEC-outlet variants of the same capacity — outlet types, cord and approvals differ, and specifications from those builds should not be read across to this one. SourceIT supplies the -MS build, which is the correct one for Singapore.\u003c\/p\u003e\n\u003ch3\u003eDoes it produce a pure sine wave — will it run an active-PFC power supply?\u003c\/h3\u003e\n\u003cp\u003eNo. This model's output on battery is a \u003cstrong\u003esquare wave\u003c\/strong\u003e, not a pure sine wave. That is entirely normal for this class of UPS and it is fine for the vast majority of office equipment: desktop PCs with conventional power supplies, monitors, routers, switches, NAS boxes, POS terminals and phone systems.\u003c\/p\u003e\n\u003cp\u003eIt matters in one case. Some modern power supplies with \u003cem\u003eactive power factor correction\u003c\/em\u003e — common in higher-end workstations, gaming PCs and some servers — can refuse to run or can shut down abruptly on a stepped or square waveform. If the equipment you are protecting has an active-PFC supply, choose a sine-wave UPS instead: the APC Smart-UPS SMT and SMC ranges are sine wave and we stock both. Ask us and we will check the specification of your PSU before you buy.\u003c\/p\u003e\n\u003ch3\u003eWhich replacement battery does it take, and can I fit it myself?\u003c\/h3\u003e\n\u003cp\u003eThe correct APC replacement cartridge is \u003cstrong\u003eAPCRBC110\u003c\/strong\u003e, which we stock: \u003ca href=\"\/products\/apc-replacement-battery-cartridge-110-apcrbc110\"\u003eAPC Replacement Battery Cartridge APCRBC110\u003c\/a\u003e. The battery is user-replaceable: the unit is designed to be opened and the cartridge swapped by the owner, with the UPS switched off and unplugged. Expect three to five years of service life in a Singapore environment; heat and humidity are what wear a sealed lead-acid battery out, so a unit living in an air-conditioned room lasts longer than one in a warm store cupboard.\u003c\/p\u003e\n\u003ch3\u003eDoes it come with shutdown software or network monitoring?\u003c\/h3\u003e\n\u003cp\u003eNo communication port is listed in the Schneider specification for this build, so we make no shutdown-software or monitoring claim for it.\u003c\/p\u003e\n\u003cp\u003eIf you need a UPS that closes files and shuts a server down cleanly when the battery runs low, or that an IT team can poll over the network, that is what the APC Smart-UPS SMT, SMC and SMX ranges are for — every one of them has a USB or serial port and most take an APC Network Management Card. We carry the full range and can quote the nearest equivalent by wattage.\u003c\/p\u003e\n\u003ch3\u003eHow does the BX625CI-MS compare with the BX750MI-MS?\u003c\/h3\u003e\n\u003cp\u003eThe BX750MI-MS is 750 VA \/ 410 W with 2 universal + 1 C13 outlets, against 625 VA \/ 325 W and 3 universal outlets on this unit. Within the APC Back-UPS BX range every model is line-interactive with AVR and surge protection — what changes as you go up the range is the watt rating, the socket count and the size of the battery, and therefore how long it holds up a given load. Check the waveform row on each listing as well, because it is not identical across the whole range. If your load is close to the ceiling of one model, buy the next one up: you gain runtime as well as headroom. See \u003ca href=\"\/products\/apc-back-ups-750va-230v-avr-universal-sockets-bx750mi-ms\"\u003eBX750MI-MS\u003c\/a\u003e for the full specification of that model.\u003c\/p\u003e\n\u003ch3\u003eIs the BX625CI-MS covered by a local Singapore warranty?\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC BX625CI-MS sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the BX625CI-MS with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003cp\u003eSchneider states this range's warranty as two years repair or replace, with no separate European Community figure — so the two-year term above is the correct one for a unit bought and used in Singapore, and it is what we honour here.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/JoErEwjle3g\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879363387556,"sku":"BX625CI-MS","price":125.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_c3f3b251-0c78-48e0-9c98-256f1119d95f.jpg?v=1789719129"},{"product_id":"apc-back-ups-pro-br-1300va","title":"APC Back UPS Pro BR 1300VA, 8 Outlets, AVR, LCD Interface","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Back UPS Pro BR 1300VA, 8 Outlets, AVR, LCD Interface (BR1300MI) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eAPC BR1300MI 1300 VA \/ 780 W UPS for Singapore's 230V \/ 50Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC BR1300MI is a 1300 VA \/ 780 W line-interactive UPS with stepped-approximation output, built for 230 V, 50 Hz supplies — exactly what Singapore's PUB grid delivers. It rides through the short dips, brownouts and momentary interruptions that follow an afternoon thunderstorm, and its Automatic Voltage Regulation corrects high and low mains voltage \u003cem\u003ewithout\u003c\/em\u003e going to battery, so the cells are not cycled every time the supply wanders. Output is 8 x C13 — 6 battery-backed, 2 surge-only.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStepped-Approximation Output — Check Your PSU Before You Order\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BR1300MI produces a stepped approximation to a sinewave on battery, which is what the Schneider data sheet states for this exact part number. That is entirely suitable for most desktop PCs, routers, switches, NVRs, POS terminals and comms-cabinet gear. If the load is an active-PFC ATX power supply that is fussy about waveform, specify a sine wave model instead — in the Back-UPS Pro BR range that is the \u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e or \u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e. We would rather tell you that up front than take the return.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutlets, Runtime and Battery Life in a Humid Climate\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOutlets are 6 x IEC 60320 C13 (battery backup and surge protection) plus 2 x IEC 60320 C13 (surge protection only). The surge-only outlets are there for printers, monitors and chargers that do not need backup but do need protection — keeping them off the battery bank is what buys you runtime on the equipment that matters. The battery is a sealed maintenance-free lead-acid (VRLA) cartridge with a 3 to 5 year expected service life. Singapore's heat and humidity are hard on VRLA cells, so plan on a cartridge change inside that window rather than at the end of it; the replacement part is \u003ca href=\"\/products\/apc-replacement-battery-cartridge-165-apcrbc165\"\u003eAPCRBC165\u003c\/a\u003e. Schneider does not publish a runtime-versus-load table for the BR1300MI, so we do not print one — runtime depends entirely on how much of the 780 W you actually draw. Tell us your load in watts and we will size it for you.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSME Office, Home Office and Comms-Cabinet Duty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis is a tower unit at 100 mm (H) x 250 mm (W) x 382 mm (D), 10.2 kg (11.85 kg packaged) — it sits on a desk, under a counter or on the floor of a comms cupboard rather than in a rack, so it costs you no rack U. An RJ45 10\/100\/1000 Base-T port is built in to protect the data line as well as the power, which is worth having on a fibre-to-the-building service where the router is the thing that keeps dying. Everything SourceIT ships is local Singapore stock with a GST invoice and local warranty support — no grey imports, no chasing an overseas RMA.\u003c\/p\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC BR1300MI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eEvery figure below is taken from the Schneider Electric product page (United Kingdom) and the APC BR1300MI product data sheet, with the replacement cartridge corroborated by the official Back-UPS Pro 230V brochure. Where Schneider does not publish a value for this exact part number, the row is left out rather than filled in from a similar model.\u003c\/p\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eBR1300MI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro, 1300VA\/780W, Tower, 230V, 8x IEC C13 outlets, AVR, LCD, User Replaceable Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro BR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive with Automatic Voltage Regulation (AVR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e1300 VA \/ 780 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003eRepair or replace; Schneider states 2 years for the rest of the world and 3 years inside the European Community, so Singapore takes the 2-year term\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupported locally by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e780 W \/ 1300 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 1 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform (on battery)\u003c\/td\u003e\n\u003ctd\u003eStepped approximation to a sinewave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003e6 x IEC 60320 C13 (battery backup and surge protection) plus 2 x IEC 60320 C13 (surge protection only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e509 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Filtering\u003c\/td\u003e\n\u003ctd\u003eFull-time multi-pole noise filtering, 10% of IEEE surge let-through, instantaneous response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e176 to 294 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 3 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e10 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003eAutomatic Voltage Regulation (AVR) — corrects high and low mains voltage without switching to battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed maintenance-free lead-acid (VRLA), user replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e16 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Battery Life\u003c\/td\u003e\n\u003ctd\u003e3 to 5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Runtime\u003c\/td\u003e\n\u003ctd\u003eNo external battery pack is documented for this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Load\u003c\/td\u003e\n\u003ctd\u003eSchneider publishes no runtime-versus-load figures for this model — contact SourceIT with your load in watts for a sizing calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Interface\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Line Protection\u003c\/td\u003e\n\u003ctd\u003eRJ45 10\/100\/1000 Base-T Ethernet data line protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Alarms\u003c\/td\u003e\n\u003ctd\u003eAlarm when on battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eNot available on this model — there is no SmartSlot for an internal network management card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e100 mm (H) x 250 mm (W) x 382 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e10.2 kg (11.85 kg packaged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Mountable\u003c\/td\u003e\n\u003ctd\u003eNo — tower form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-15 to 45 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e45 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, RCM, C-Tick, A-Tick, EAC, TISI, GS Mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e0731304346906\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe BR1300MI presents 8 x C13 — 6 battery-backed, 2 surge-only. All outlets are IEC 60320 C13, so a standard C13 kettle lead connects a PC, monitor, switch, router or NAS directly. Only the battery-backed outlets carry the load through an outage; the surge-only outlets stay dead when the mains fails, which is the point — put the printer and the monitor there and keep the battery for the machine that must not stop. The unit takes its own supply through an IEC 60320 C14 inlet on a normal 13 A Singapore wall socket — no dedicated circuit and no electrician needed.\u003c\/p\u003e\n\u003ch4\u003eSizing it: VA, watts and how much you can actually load\u003c\/h4\u003e\n\u003cp\u003eThe BR1300MI is rated 1300 VA apparent power and 780 W real power. Size against the \u003cstrong\u003ewatts\u003c\/strong\u003e, not the VA — the watt figure is the one that runs out first on modern IT loads. As a working rule, keep the connected load under about 70% of 780 W so you have headroom for inrush and for the battery ageing. Schneider publishes no runtime table for this model, so any minutes figure you see quoted elsewhere is someone's estimate, not a manufacturer specification. Send us your equipment list and we will work out the real number.\u003c\/p\u003e\n\u003ch4\u003eBattery and replacement cartridge\u003c\/h4\u003e\n\u003cp\u003eThe battery is a sealed maintenance-free lead-acid (VRLA) cartridge. Typical recharge time is 16 h. The APC replacement cartridge for this model is \u003cstrong\u003eAPCRBC165\u003c\/strong\u003e — \u003ca href=\"\/products\/apc-replacement-battery-cartridge-165-apcrbc165\"\u003eAPCRBC165\u003c\/a\u003e is stocked by SourceIT. The cartridge is user-replaceable from the front of the unit; APC does not describe this model's battery as swappable while running, so plan a short shutdown for the change.\u003c\/p\u003e\n\u003ch4\u003eRack space and management software\u003c\/h4\u003e\n\u003cp\u003eThis is a tower unit and is not rack mountable, so it consumes no rack U and needs no rail kit. This model has no SmartSlot, so an AP9640 or AP9641 Network Management Card cannot be fitted — if you need SNMP monitoring or an Ethernet-managed UPS, step up to the APC Smart-UPS range and we will quote it. Bundled shutdown software is not documented for this model in the Schneider material we can verify, so we do not claim it; ask us and we will confirm what ships in the current carton.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Back-UPS Pro BR Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cp\u003eSchneider does not itemise the carton contents for this model in the documentation we can verify, so we will not invent a list. What we can tell you is that the unit ships as a complete tower UPS with its battery installed. If the exact carton contents matter for your tender or your install, ask us before you order and we will open a unit and tell you what is actually in it.\u003c\/p\u003e\n\u003ch4\u003eAPC Back-UPS and Back-UPS Pro BR range at SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-500va-300w-tower-230v-br500ci-as\"\u003eBR500CI-AS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS, 500VA \/ 300W tower, 3x C13 — 500 VA \/ 300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-650va\"\u003eBR650MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 650VA \/ 390W tower, 6x C13 — 650 VA \/ 390 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-900va\"\u003eBR900MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 900VA \/ 540W tower, 6x C13 — 900 VA \/ 540 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1200VA \/ 720W tower, 8x C13, sine wave, USB A+C — 1200 VA \/ 720 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBR1300MI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBack-UPS Pro, 1300VA \/ 780W tower, 8x C13 — 1300 VA \/ 780 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1500va-865w-tower-230v-10x-iec-c13-outlets-avr-lcd-br1500gi\"\u003eBR1500GI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1500VA \/ 865W tower, 10x C13, external pack capable — 1500 VA \/ 865 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1600va-960w-tower-230v-br1600mi\"\u003eBR1600MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13 — 1600 VA \/ 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13, sine wave, USB A+C — 1600 VA \/ 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-external-battery-pack-for-1500va-back-ups-pro-models-br24bpg\"\u003eBR24BPG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro external battery pack, 24 V \/ 372 VAh (for BR1500GI) — Battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMatching replacement battery cartridge\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003eAPCRBC165\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for the BR1300MI — \u003ca href=\"\/products\/apc-replacement-battery-cartridge-165-apcrbc165\"\u003eAPCRBC165\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003cp\u003eRail kits and network management cards do not apply to this range: every Back-UPS Pro BR model is a tower with no SmartSlot. For rack-mount or network-managed power protection, ask us about the APC Smart-UPS SMT, SMC and SMX ranges.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eLinks open on Schneider Electric's own site. Each one was checked before publication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/BR1300MI\/apc-backups-pro-1300va-780w-tower-230v-8x-iec-c13-outlets-avr-lcd-user-replaceable-battery\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for the APC BR1300MI\u003c\/a\u003e — official product name, characteristics and the full document list (United Kingdom site)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/SPD_AHUG-B59B4X_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Back-UPS Pro BR650\/900\/1300\/1600MI User Manual (Schneider document library)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's direct datasheet PDF links sit behind a path that blocks automated retrieval, so we link the product page and the document library entry instead — every link above resolves and carries the current document. If you need the datasheet or manual emailed to you as a file for a tender submission, ask us and we will send it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC BR1300MI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 1300 VA and the 780 W rating?\u003c\/h4\u003e\n\u003cp\u003e1300 VA is apparent power and 780 W is real power. Your equipment consumes real power, so the 780 W figure is the one that limits what you can connect. Add up the wattage on the nameplates of everything you intend to back up and keep the total comfortably below 780 W.\u003c\/p\u003e\n\u003ch4\u003eHow long will the BR1300MI run my equipment?\u003c\/h4\u003e\n\u003cp\u003eIt depends entirely on load, and Schneider publishes no runtime table for this model — which is why you will not find minutes quoted on this page. A lightly loaded unit runs for many minutes; one near 780 W runs for a few. Send SourceIT your load in watts and we will calculate it against the published battery rating rather than guess.\u003c\/p\u003e\n\u003ch4\u003eWhat does the \"MI\" in BR1300MI mean?\u003c\/h4\u003e\n\u003cp\u003eIt identifies the build variant. MI is the 230 V IEC-outlet build sold across Asia, the Middle East and Europe, with a stepped-approximation output waveform and no USB charging ports. These suffixes are not interchangeable — outlet counts, waveform and battery cartridge all change with them, so order by the exact part number.\u003c\/p\u003e\n\u003ch4\u003eIs the output a pure sine wave, and will it drive an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eNo. The BR1300MI produces a stepped approximation to a sinewave, as stated in its data sheet. That is fine for most desktops, routers, switches, NVRs and POS gear, but some active-PFC ATX power supplies will alarm or drop out on it. If your load has an active-PFC supply, choose the \u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e or \u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e instead — both are sine wave.\u003c\/p\u003e\n\u003ch4\u003eWhich replacement battery does it take, and can I fit it myself?\u003c\/h4\u003e\n\u003cp\u003eThe APC replacement battery cartridge for the BR1300MI is \u003cstrong\u003eAPCRBC165\u003c\/strong\u003e, stocked here: \u003ca href=\"\/products\/apc-replacement-battery-cartridge-165-apcrbc165\"\u003eAPCRBC165\u003c\/a\u003e. It is user-replaceable — no tools beyond a screwdriver and no service call. APC does not describe this model's battery as swappable while running, so shut the unit down for the swap. Expect three to five years of service in an air-conditioned office, and less in a hot, humid comms cupboard.\u003c\/p\u003e\n\u003ch4\u003eCan I rack mount it or add a network management card?\u003c\/h4\u003e\n\u003cp\u003eNo on both counts. The BR1300MI is a tower unit with no rack ears or rail kit option, and the Back-UPS Pro BR range has no SmartSlot, so an AP9640 or AP9641 card cannot be fitted. If you need a 19-inch rack UPS or SNMP monitoring, ask SourceIT about the APC Smart-UPS SMT, SMC and SMX ranges.\u003c\/p\u003e\n\u003ch4\u003eHow does the BR1300MI compare with the BR1600MI?\u003c\/h4\u003e\n\u003cp\u003eThe \u003ca href=\"\/products\/apc-back-ups-pro-1600va-960w-tower-230v-br1600mi\"\u003eBR1600MI\u003c\/a\u003e adds 300 VA and 180 W in the same 100 x 250 x 382 mm chassis with the same outlet layout, for a modest price step. Both are stocked by SourceIT in Singapore — tell us the load and the budget and we will tell you which one is the right buy.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC BR1300MI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the BR1300MI with a 2-year manufacturer warranty. Note that Schneider states three years inside the European Community and two years elsewhere — Singapore takes the two-year term, and any listing quoting three years for this market has copied the European figure.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/dZ-hRA5gJ48\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879366467748,"sku":"BR1300MI","price":695.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_2f25e273-9619-4056-a5d2-da22c7820af4.jpg?v=1789719185"},{"product_id":"apc-ups-network-management-card-3-ap9640","title":"APC UPS Network Management Card 3","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC UPS Network Management Card 3, Gigabit Ethernet, Secure Remote UPS Monitoring (AP9640) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eSecure Remote UPS Monitoring and Management Over Your Network\u003c\/h3\u003e\n\u003cp\u003eThe APC UPS Network Management Card 3 (AP9640) installs in a Smart-UPS SmartSlot bay and gives the UPS its own IP address, web interface, command line and SNMP agent. From there you can see load, battery status, runtime and input conditions, receive real-time event notification, and pull detailed data and event logs - without walking to the rack.\u003c\/p\u003e\n\u003cp\u003eNMC3 is the current generation of APC's management card and it is a security-led design: HTTPS with TLS, SSH, SNMPv3, RADIUS authentication and 802.1X port-based network access control are all supported, alongside the older HTTP, Telnet and SNMPv1 methods where a legacy monitoring system still needs them.\u003c\/p\u003e\n\u003ch3\u003eProtocol Coverage for NMS, BMS and Building Automation\u003c\/h3\u003e\n\u003cp\u003eThe card speaks the protocols a mixed Singapore estate actually runs on. For network monitoring: SNMP v1, v2c and v3, Syslog and SMTP e-mail alerting. For building and industrial systems: Modbus TCP\/IP and BACnet\/IP, so a UPS in a comms room can report into the same head-end as the chillers and the access control. For file transfer and firmware work: FTP and SCP. Addressing covers DHCP, BOOTP and NTP time sync.\u003c\/p\u003e\n\u003cp\u003eThe card is also the network half of PowerChute Network Shutdown, which lets a UPS gracefully shut down physical and virtual servers when runtime runs short - the piece most SME server rooms miss until the first long outage.\u003c\/p\u003e\n\u003ch3\u003eGigabit Ethernet and a One-Year Secure NMC System Subscription\u003c\/h3\u003e\n\u003cp\u003eConnection is a single 10\/100\/1000 Base-T RJ45 port, with a micro-USB console port for local configuration. Every AP9640 includes a one-year Secure NMC System subscription, Schneider's programme for keeping card firmware current against new vulnerabilities - a point worth raising with any customer who has to answer a security audit.\u003c\/p\u003e\n\u003cp\u003eThe card is EcoStruxure IT compatible, so it can report into Schneider's monitoring platform alongside the rest of the estate.\u003c\/p\u003e\n\u003ch3\u003eBuilt for Server Rooms and Comms Cabinets on Singapore's 230V Mains\u003c\/h3\u003e\n\u003cp\u003eA UPS that nobody can see is a UPS nobody maintains. Fitting an AP9640 turns a standalone Smart-UPS into a monitored asset: you get e-mail alerts and SNMP traps on UPS and power events, and detailed data and event logs that tell you how often the PUB supply actually dipped during the last storm season.\u003c\/p\u003e\n\u003cp\u003eThe card runs at 0 to 45 °C and 0 to 95% humidity. Supplied and invoiced locally in Singapore with GST.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP9640 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP9640\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eNetwork Management Card 3 (NMC3), secure remote UPS monitoring and management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eAPC SmartSlot plug-in card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Subscription\u003c\/td\u003e\n\u003ctd\u003e1-Year Secure NMC System subscription\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Sensor Ports\u003c\/td\u003e\n\u003ctd\u003eNone - see AP9641 for a card with universal I\/O ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eGreen Premium, EU RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eYes - supplied and supported locally by SourceIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFunction \u0026amp; Connectivity\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Port\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100\/1000 Base-T Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003e1 x micro-USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb \u0026amp; Terminal Access\u003c\/td\u003e\n\u003ctd\u003eHTTP, HTTPS (TLS), SSH, Telnet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Monitoring\u003c\/td\u003e\n\u003ctd\u003eSNMP v1, SNMP v2c, SNMP v3, Syslog, SMTP e-mail alerts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding \u0026amp; Industrial\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP, BACnet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFile Transfer\u003c\/td\u003e\n\u003ctd\u003eFTP, SCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuthentication \u0026amp; Access\u003c\/td\u003e\n\u003ctd\u003eRADIUS, 802.1X (EAPoL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing \u0026amp; Time\u003c\/td\u003e\n\u003ctd\u003eDHCP, BOOTP, NTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutdown Software\u003c\/td\u003e\n\u003ctd\u003ePowerChute Network Shutdown supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Platform\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure IT compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware (Smart-UPS)\u003c\/td\u003e\n\u003ctd\u003eNMC3 firmware v2.5.5.1, released 13 June 2025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e38 x 121 x 114 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.08 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Weight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimensions\u003c\/td\u003e\n\u003ctd\u003e23.5 x 15.9 x 5.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 10,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 15,240 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eEN 55022 Class A, EN 55024, ICES-003, AS\/NZS 3548 (C-Tick) Class A, FCC Part 15 Class A, GOST, VCCI Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhich UPS families accept the AP9640.\u003c\/strong\u003e The card fits an APC SmartSlot bay. Schneider's UPS network management card compatibility chart lists single-phase support for SUA, SUM, SURT, SURTA, SURTD and SUVT legacy units, MGE Galaxy 3500, and the current SMT, SMX, SRT, SRC, SMTL, SRTL and SRYL ranges, plus Symmetra LX and Symmetra RM at firmware v1.5.1.1 or later. Three-phase support covers Symmetra PX1 20\/40\/48 kW, Symmetra PX2 96\/100\/160 kW, Galaxy VM, Galaxy VX, Galaxy PX, Galaxy 3L Pro, Easy UPS 3-Phase Modular and Easy UPS 3M Advanced. Legacy SUA units must be manufactured after 2008 and running firmware v1.4.2 or later.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn the SourceIT catalogue\u003c\/strong\u003e that covers the Smart-UPS SmartConnect range (SMT and SMC), the Smart-UPS X range - for example the \u003ca href=\"\/products\/apc-smart-ups-x-1500va-rack-tower-lcd-230v-smx1500rmi2u\"\u003eSMX1500RMI2U\u003c\/a\u003e - and the Smart-UPS On-Line SRT range, such as the \u003ca href=\"\/products\/apc-smart-ups-on-line-3kva-rackmount-2u-230v-8x-c13-2x-c19-iec-srt3000rmxli\"\u003eSRT3000RMXLI\u003c\/a\u003e. Note that the \"NC\" variants of the Smart-UPS X ship with a management card already fitted and no free SmartSlot - check before ordering a second card.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many SmartSlots do I have?\u003c\/strong\u003e Most single-phase Smart-UPS models have exactly one. That slot can hold this card, the \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641\u003c\/a\u003e, or the \u003ca href=\"\/products\/apc-dry-contact-i-o-smartslot-card-ap9613\"\u003eAP9613 dry contact card\u003c\/a\u003e - not two of them. Choose on function: AP9640 for network management alone, AP9641 if you also want temperature and humidity sensing from the same slot.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSensors.\u003c\/strong\u003e The AP9640 has no universal I\/O ports, so it does not take the AP9335T or AP9335TH sensors. If environmental monitoring is part of the requirement, specify the AP9641 instead, or add a \u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNetBotz Rack Monitor 250 (NBRK0250A)\u003c\/a\u003e for rack-level sensing and door access control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot for Rack PDUs.\u003c\/strong\u003e APC Rack PDUs with network management - the AP79xx, AP88xx and APDU ranges - have their own network port built in and do not use a Network Management Card. The AP9640 is for UPS SmartSlot bays only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can do once it is on the network.\u003c\/strong\u003e Browser and command-line management, SNMP polling and traps into your NMS, e-mail alerts, Syslog, scheduled self-tests, event and data logs, firmware updates over the network, Modbus TCP\/IP or BACnet\/IP into a BMS, and graceful server shutdown through PowerChute Network Shutdown.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; APC Network Management Card 3 Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eIn the box:\u003c\/strong\u003e Network Management Card 3, user manual, USB cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPC Network Management Card 3 range and related management options\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eWhat it adds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP9640 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork management - Gigabit Ethernet, no sensor ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNetwork management plus 2 universal I\/O ports, 3 USB ports, Modbus RTU over serial; ships with an AP9335T temperature sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-dry-contact-i-o-smartslot-card-ap9613\"\u003eAP9613\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eDry contact signalling only - 4 input contacts, 6 output relays; no network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSensors and rack monitoring\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature and humidity sensor, RJ45, 3.9 m lead - requires a host with universal I\/O ports (the AP9641 or the AP9613) or a NetBotz appliance; it will not connect to the AP9640\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNBRK0250A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNetBotz Rack Monitor 250 - 1U appliance, 6 universal sensor ports, badged access control for two rack doors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSmart-UPS models in the SourceIT catalogue that take this card\u003c\/strong\u003e - confirm the SmartSlot is free before ordering\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-1500va-lcd-rm-2u-230v-with-smartconnect-smt1500rmi2uc\"\u003eSMT1500RMI2UC\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 1500VA LCD RM 2U 230V with SmartConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-2200va-lcd-rm-2u-230v-with-smartconnect-smt2200rmi2uc\"\u003eSMT2200RMI2UC\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 2200VA LCD RM 2U 230V with SmartConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-1500va-rack-tower-lcd-230v-smx1500rmi2u\"\u003eSMX1500RMI2U\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS X 1500VA Rack\/Tower LCD 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-on-line-3kva-rackmount-2u-230v-8x-c13-2x-c19-iec-srt3000rmxli\"\u003eSRT3000RMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS On-Line 3kVA Rackmount 2U 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP9640. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/product\/AP9640\/apc-ups-network-management-card-3\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page - AP9640 UPS Network Management Card 3\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/iportal.se.com\/Contents\/docs\/AP9640_DATASHEET.PDF\" target=\"_blank\" rel=\"noopener\"\u003eAPC AP9640 product data sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/iportal.se.com\/Contents\/docs\/UPS%20NETWORK%20MANAGEMENT%20CARD%203_USER%20GUIDE.PDF\" target=\"_blank\" rel=\"noopener\"\u003eUPS Network Management Card 3 user guide (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/APC_NMC3_SU_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eNMC3 firmware for Smart-UPS - current release\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/faqs\/FA237786\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric FAQ FA237786 - UPS Network Management Card compatibility chart\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed a specific document, a compliance declaration or a written quotation? Contact SourceIT and we will supply it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP9640\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the AP9640 and the AP9641?\u003c\/h4\u003e\n\u003cp\u003eSensor ports. The AP9640 has none. The \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641\u003c\/a\u003e adds two universal I\/O ports that accept the AP9335T temperature sensor or the AP9335TH temperature and humidity sensor, plus three USB ports rather than one micro-USB console, Modbus RTU over serial, and support for the AP9834 Wi-Fi dongle. The AP9641 also ships with an AP9335T temperature sensor in the box. Network management itself is the same on both cards. If you have one SmartSlot and any interest in rack temperature, the AP9641 is usually the better buy.\u003c\/p\u003e\n\u003ch4\u003eWill it fit my UPS?\u003c\/h4\u003e\n\u003cp\u003eIt needs a free SmartSlot. Schneider's compatibility chart covers SMT, SMX, SRT, SRC, SMTL, SRTL and SRYL current ranges plus SUA, SUM, SURT, SURTA, SURTD, SUVT and MGE Galaxy 3500 legacy units, Symmetra LX and RM, and the three-phase Symmetra PX and Galaxy families. Legacy SUA units need post-2008 manufacture and firmware v1.4.2 or later. Send us your UPS part number and we will confirm both compatibility and whether the slot is already occupied.\u003c\/p\u003e\n\u003ch4\u003eCan I use it with an APC Rack PDU?\u003c\/h4\u003e\n\u003cp\u003eNo, and you do not need to. APC's managed Rack PDUs - the AP79xx, AP88xx and APDU Advanced ranges - have network management built into the unit with their own Ethernet port, web interface and SNMP agent. Network Management Cards are for UPS SmartSlot bays.\u003c\/p\u003e\n\u003ch4\u003eWhich protocols does it support?\u003c\/h4\u003e\n\u003cp\u003eHTTP and HTTPS with TLS, SSH, Telnet, SNMP v1, v2c and v3, FTP, SCP, Modbus TCP\/IP, BACnet\/IP, RADIUS, 802.1X (EAPoL), DHCP, BOOTP, NTP, Syslog and SMTP. That covers modern secure management, legacy monitoring systems and building automation head-ends.\u003c\/p\u003e\n\u003ch4\u003eWhat is the Secure NMC System subscription that comes with it?\u003c\/h4\u003e\n\u003cp\u003eEvery AP9640 includes a one-year Secure NMC System subscription, Schneider's programme for keeping the card's firmware current against newly disclosed vulnerabilities. It is a useful line to have on file if your organisation has to evidence patching of network-connected infrastructure.\u003c\/p\u003e\n\u003ch4\u003eDoes it let servers shut down automatically?\u003c\/h4\u003e\n\u003cp\u003eYes, in combination with PowerChute Network Shutdown, which the card supports. PowerChute talks to the card over the network and shuts physical and virtual machines down gracefully before the battery runs out. Ask SourceIT about licensing for your host count.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC AP9640 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the AP9640 with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879369875620,"sku":"AP9640","price":555.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_ee57a385-098d-4f97-b643-20adbc102c6a.jpg?v=1789719235"},{"product_id":"apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out","title":"APC NetShelter Rack ATS 1U 16A 230V, 2 C20 In, 8 C13 1 C19 Out","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Rack ATS 1U 16A 230V, 2 C20 In, 8 C13 1 C19 Out (AP4423A) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e16 A Source Redundancy with a C19 Outlet\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Rack ATS AP4423A gives single-corded equipment two independent power sources and switches between them automatically. Its 16 A, 3,700 VA rating and mixed outlet layout - eight IEC C13 plus one IEC C19 - suit a cabinet that mixes ordinary network gear with one heavier device such as a blade chassis, storage shelf or large switch that needs a 16 A C20 connection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTransfers in 10 ms or Less\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen the preferred source drifts outside tolerance the AP4423A transfers the load to the alternate feed in 10 ms maximum on the high sensitivity setting, or 12 ms maximum on low sensitivity. That is short enough for a normal server power supply to ride through without rebooting. Sensitivity, transfer ranges and source preference are set from the front panel or the Web UI.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDesigned for 230 V Singapore Racks\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRated at 230 V AC nominal with a 207 to 253 V window and 50\/60 Hz operation, the AP4423A runs directly on Singapore mains. Feeding one input from a UPS and the other from a separate breaker or riser turns a single-PSU appliance into something that survives the loss of either feed - the same protection a dual-PSU server gets for free.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFifth-Generation Management: NMC3, Colour LCD, Sensor Port\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AP4423A carries Schneider's Network Management Card 3 as standard, and the NMC\/display module is field-replaceable. Gigabit Ethernet, a secure Web UI, SSH, SNMP v1 and v3, Modbus TCP and EcoStruxure IT integration are all built in. The colour LCD shows both sources' voltage and frequency, load in amps, alarms and the preferred source; the Universal I\/O port takes an AP9335T or AP9335TH sensor; and the Link A\/B ports let up to 32 Rack ATS units share a single IP address. In a 1U chassis 236 mm deep, it fits comms cabinets and server racks alike.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP4423A Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Rack Automatic Transfer Switch, 1U, 16A, 230V, 2 C20 IN, 8 C13, 1 C19 OUT, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP4423A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Rack ATS, fifth generation (AP44XXA series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRack-mount Automatic Transfer Switch (ATS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e1U, 19-inch rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric); 5-year extended warranty available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connections\u003c\/td\u003e\n\u003ctd\u003eTwo (2) IEC 60320 C20 inlets, 16 A 2P+E (Source A and Source B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e207 to 253 V (±10% of nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Current\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Line Current (as printed by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003ctd\u003eNot fitted (without circuit breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Cords\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric as supplied - ask us to quote a pair of 16 A C19-to-C20 input cords with the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eEight (8) IEC 60320 C13 and one (1) IEC 60320 C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per C13 Outlet\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per C19 Outlet\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Capacity\u003c\/td\u003e\n\u003ctd\u003e3,700 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum (high sensitivity); 12 ms maximum (low sensitivity); typical total transfer 8 to 12 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Technology\u003c\/td\u003e\n\u003ctd\u003eBreak-before-make relay switching; sources may be up to 180 degrees out of phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunications \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management Card\u003c\/td\u003e\n\u003ctd\u003eNetwork Management Card 3 (NMC3) integrated as standard; the NMC\/display module is field-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Port\u003c\/td\u003e\n\u003ctd\u003eGigabit Ethernet (10\/100\/1000) with link status LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interfaces\u003c\/td\u003e\n\u003ctd\u003eWeb UI (HTTP\/HTTPS), Command Line Interface (SSH\/SCP, Telnet), SNMP v1 and v3 with traps, Modbus TCP, FTP, Syslog, e-mail notification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Platform\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure IT compatible (alerts and control for one or many ATS units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Port Sharing\u003c\/td\u003e\n\u003ctd\u003eLink A and Link B ports: up to 32 AP44XXA Rack ATS units share one network connection and one IP address; one unit acts as host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003eMicro-USB for local CLI access (cable not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003eUSB-A for firmware upgrade from a USB drive and for the optional APC AP9834 Wi-Fi USB device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Sensor Port\u003c\/td\u003e\n\u003ctd\u003eUniversal I\/O port for the optional AP9335T temperature sensor or AP9335TH temperature\/humidity sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Display\u003c\/td\u003e\n\u003ctd\u003eColour LCD rotating through four default screens: Source A and B voltage and frequency, load per bank and total load in amps, alarm status, preferred source; Home\/Down\/Select buttons; backlight off after 10 minutes of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource Preference\u003c\/td\u003e\n\u003ctd\u003eSelectable - Source A, Source B, or no preference, from the front panel or remotely\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Sensitivity\u003c\/td\u003e\n\u003ctd\u003eSelectable high or low; up to three configurable transfer ranges (one active at a time) and a frequency deviation setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcurrent Users\u003c\/td\u003e\n\u003ctd\u003eUp to four users logged in simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware\u003c\/td\u003e\n\u003ctd\u003eFlash-upgradeable over the network or from a USB drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e43.7 x 431.8 x 236.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e3.74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e5.51 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 15,240 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e114 x 600 x 356 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards (as printed by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003ecUL Listed; UL Listed; CE; EN 55022 Class A; FCC Part 15 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS \/ REACh\u003c\/td\u003e\n\u003ctd\u003eEU RoHS compliant, lead-free and mercury-free; REACh declaration available from Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Load Planning\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Eight IEC C13 outlets take standard C14 equipment cords - switches, routers, firewalls, appliances, 1U and 2U servers. The single IEC C19 outlet is rated to 16 A and takes a C20 cord, which is what larger blade chassis, storage shelves and big core switches use. There is one C19 on this model, not two; if you need two, step up to the \u003ca href=\"\/products\/apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424\"\u003eAP4424A\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLoad planning.\u003c\/strong\u003e Rated capacity is 3,700 VA at 16 A. Plan against that figure and your equipment's nameplate current, not the outlet count. Remember that during a failover a single source carries the whole load, so both feeds and both upstream breakers must be sized for the full 16 A, not half of it. The unit has no internal circuit breaker, so protection comes from the branch circuit feeding each source.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e 1U high, 431.8 mm wide, 236.2 mm deep. The shallow depth suits wall-mount and comms cabinets as well as full-depth racks. The 1U rack-mount bracket kit, screws, cage nuts and clip-on nuts are in the box; front and rear rail segments and a cord retention bracket are not.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeeding it.\u003c\/strong\u003e Both inlets are IEC C20, so each source needs a C19-to-C20 cord rated for 16 A - do not feed a 16 A unit through a 10 A C13 cord and an adapter. The two sources must be genuinely independent for the redundancy to mean anything: separate UPS units, or separate breakers on separate risers. Both cords into one PDU protects against nothing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eManagement.\u003c\/strong\u003e The AP4423A carries Schneider's Network Management Card 3 as standard - there is no SmartSlot to populate and no card to buy. You get a Gigabit Ethernet port, a secure Web UI over HTTP\/HTTPS, a CLI over SSH, SNMP v1 and v3 with traps, Modbus TCP for a building management system, Syslog and e-mail alerts, and EcoStruxure IT integration. The NMC\/display module can be swapped in the field, so a damaged card is a spare-part exchange rather than a whole-unit return. The micro-USB console cable is not in the box.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental monitoring.\u003c\/strong\u003e The Universal I\/O port accepts the optional AP9335T temperature sensor or the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH temperature and humidity sensor\u003c\/a\u003e, so a comms cabinet with no other monitoring can report rack temperature through the same IP address as its power switching. Thresholds and alarms are set in the same Web UI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMany units, one IP.\u003c\/strong\u003e With Link A and Link B on the front panel, up to 32 AP44XXA-series Rack ATS units can be chained so that one network connection serves them all. One unit is the host; the rest appear under it in the Web UI and in SNMP. \u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; NetShelter Rack ATS Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC NetShelter Rack ATS (AP4423A)\u003c\/li\u003e\n\u003cli\u003e1U rack-mount bracket kit\u003c\/li\u003e\n\u003cli\u003ePhillips screws (10-32 x 0.5 in), cage nuts and clip-on nuts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInput power cords: the AP4423A has C20 inlets, so budget a 16 A C19-to-C20 cord for each source and ask us to include them on the quotation. A micro-USB cable for the console port is not included; any standard micro-USB data cable will do. Front and rear rail segments and a cord retention bracket are optional accessories and are not in the box.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eNetShelter Rack ATS Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-10a-c14-in-12-c13-out\"\u003eAP4421A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 10 A, 2,000 VA\u003c\/td\u003e\n\u003ctd\u003e2 x IEC C14 inlets\u003c\/td\u003e\n\u003ctd\u003e(12) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP4423A (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 16 A, 3,700 VA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2 x IEC C20 inlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(8) C13, (1) C19\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424\"\u003eAP4424A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7,400 VA\u003c\/td\u003e\n\u003ctd\u003e2 x IEC 60309 32 A\u003c\/td\u003e\n\u003ctd\u003e(16) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335TH\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAPC Temperature \u0026amp; Humidity Sensor\u003c\/a\u003e - plugs into the Universal I\/O port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335T\u003c\/td\u003e\n\u003ctd\u003eAPC Temperature Sensor - plugs into the Universal I\/O port; ask us for availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9834\u003c\/td\u003e\n\u003ctd\u003eAPC Wi-Fi USB device for cable-free setup and management via the USB-A port; ask us for availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eSchneider Electric hosts the official documentation for the AP44XXA-series Rack ATS. The links below are the document landing pages and product page that resolve to the correct part number. Links open in a new tab.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct overview and specifications\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-91724_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eNetShelter Rack ATS AP4423A Overview and Specifications (990-91724_EN)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-91718_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eRack ATS with Network Management Card 3 User Guide AP44XXA (990-91718_EN)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical brochure\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/sg\/en\/download\/document\/AP44xxA_Technical_Brochure\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC NetShelter Rack ATS Fifth Generation AP44xxA Series Technical Brochure\u003c\/a\u003e — Singapore site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric product page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/AP4423A\/apc-netshelter-rack-automatic-transfer-switch-1u-16a-230v-2-c20-in-8-c13-1-c19-out-50-60hz\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC AP4423A on se.com\u003c\/a\u003e — Singapore site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eSchneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eAP4423A\u003c\/strong\u003e and we will send you the current PDF datasheet and user guide directly.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP4423A\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy only one C19 outlet, and what fits it?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AP4423A's layout is eight C13 plus one C19 - Schneider's own product name says so. The C19 is rated to 16 A and accepts a C20 cord, which is what blade chassis, larger storage shelves and some core switches use. If your cabinet has two such devices, the \u003ca href=\"\/products\/apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424\"\u003eAP4424A\u003c\/a\u003e has two C19 outlets and a 32 A, 7,400 VA rating.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes the AP4423A have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider states this plainly in the AP44XXA user guide (990-91718): the Rack ATS does not include power surge protection, and it recommends connecting each Rack ATS source to a double-conversion on-line UPS. Claims of surge suppression against this part are incorrect. If surge and dip protection is what you actually need, an on-line UPS such as the Smart-UPS SRT range in front of the ATS is the right answer, and it also gives the ATS a genuinely independent second source.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs network management built in, or do I need to buy a card?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBuilt in. The AP4423A ships with Network Management Card 3 integrated - Gigabit Ethernet, Web UI over HTTP\/HTTPS, SSH, SNMP v1 and v3, Modbus TCP and EcoStruxure IT support are all standard. You do not buy a card for it. If the module is ever damaged it can be replaced in the field rather than sending the whole switch away.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan it monitor rack temperature and humidity?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes, with an optional sensor. Plug an AP9335T (temperature) or \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH (temperature and humidity)\u003c\/a\u003e into the Universal I\/O port and the readings, thresholds and alarms appear in the same Web UI and SNMP tree as the power data. No NetBotz appliance is needed for a single-cabinet site.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat does \"manage up to 32 ATS from one IP address\" mean in practice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEach AP44XXA-series unit has Link A and Link B ports. Chain up to 32 units through those ports, connect only the host unit to your network, and every unit in the group is visible and configurable through that one IP address. It saves a switch port and an address per cabinet and keeps the whole estate under one login.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow fast does it transfer, and will my servers notice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA maximum of 10 ms on the high sensitivity setting, 12 ms on low sensitivity, with Schneider quoting a typical total transfer of 8 to 12 ms. That is inside the hold-up time of a normal server or network power supply, so equipment generally rides through without restarting. High sensitivity reacts sooner to a marginal source; low sensitivity tolerates more deviation before acting, which is useful when a generator feed would otherwise make the unit transfer more often than you want. The two sources may be up to 180 degrees out of phase.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does the AP4423A differ from the AP4423 it replaces?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe electrical side is unchanged: same 16 A, 230 V rating, same inlet type and the same outlet configuration, so the AP4423A drops into an existing AP4423 installation without rewiring. What Schneider changed is the management module. The AP4423A moves from Network Management Card 2 to Network Management Card 3, and that card and its display are now field-replaceable. It adds a Universal I\/O port for an AP9335T or AP9335TH sensor, Link A and Link B ports for Network Port Sharing of up to 32 units on one IP address, Gigabit Ethernet in place of 10\/100, a colour LCD, a micro-USB console port instead of the old RJ12 serial lead, a USB-A port for firmware upgrade and the AP9834 Wi-Fi device, Modbus TCP, updated security (secured interfaces and a stricter password policy) and EcoStruxure IT integration. The standard warranty stays at 2 years.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does it compare with the AP4421A and AP4424A?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThree power classes on the same NMC3 platform. \u003ca href=\"\/products\/apc-rack-ats-230v-10a-c14-in-12-c13-out\"\u003eAP4421A\u003c\/a\u003e: 10 A, 2,000 VA, C14 inlets, twelve C13, 1U. AP4423A (this listing): 16 A, 3,700 VA, C20 inlets, eight C13 plus one C19, 1U. \u003ca href=\"\/products\/apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424\"\u003eAP4424A\u003c\/a\u003e: 32 A, 7,400 VA, IEC 60309 inputs, sixteen C13 plus two C19, and 2U rather than 1U. Pick on total current draw first, then on whether you need C19 outlets.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Rack ATS AP4423A sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs the AP4423A with a 2-year manufacturer warranty, and a 5-year extended warranty is offered by Schneider - ask us to quote it with the unit.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879372431524,"sku":"AP4423A","price":1905.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_dfe39a64-d7e0-41bc-a110-7d62894bbefb.jpg?v=1789701462"},{"product_id":"apc-rack-ats-230v-10a-c14-in-12-c13-out","title":"APC NetShelter Rack ATS 1U 10A 230V, C14 In, 12 C13 Out","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Rack ATS 1U 10A 230V, C14 In, 12 C13 Out (AP4421A) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eAutomatic Source Failover for Single-Corded Equipment\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMost switches, routers, appliances and entry-level servers ship with a single power supply, which makes them the weakest link in an otherwise redundant rack. The APC NetShelter Rack ATS AP4421A sits between two independent 230 V feeds and the equipment, transferring the load to the alternate source when the preferred one drifts out of tolerance. Transfer completes in 10 ms or less on the high sensitivity setting, well inside the ride-through of a normal IT power supply.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBuilt for Singapore's 230 V \/ 50 Hz Supply\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AP4421A is a 230 V, 50\/60 Hz unit that accepts 207 to 253 V, so it works directly on Singapore mains without a step transformer. Pairing one feed from a UPS with a second from a different riser or a second UPS gives a comms cabinet genuine source diversity, which matters during the voltage dips that accompany a heavy afternoon storm on the PUB network. Rated capacity is 2,000 VA at 10 A.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTwelve C13 Outlets in a Single Rack U\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTwo IEC C14 inlets feed twelve IEC C13 outlets across a 1U chassis just 236 mm deep, so the unit fits shallow comms cabinets as easily as a full-depth server rack. Twelve outlets is enough to cover a stack of switches and appliances from one transfer switch rather than duplicating hardware.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eNetwork Management Card 3, Colour LCD and Sensor Port Built In\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AP4421A is the fifth-generation NetShelter Rack ATS, and the difference from the earlier AP4421 is all in the management. Schneider's Network Management Card 3 is integrated as standard and the NMC\/display module can be replaced in the field. It brings a Gigabit Ethernet port, a secure Web UI, SSH, SNMP v1 and v3, Modbus TCP and EcoStruxure IT integration; a colour LCD that cycles through source voltage and frequency, load in amps, alarms and the preferred source; a Universal I\/O port for an AP9335T or AP9335TH temperature\/humidity sensor; and Link A\/B ports that let up to 32 Rack ATS units share one IP address. There is no card to buy separately.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP4421A Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC Netshelter Rack Automatic Transfer Switch, 1U, 10A, 230V, C14 IN, 12 C13 OUT, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP4421A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Rack ATS, fifth generation (AP44XXA series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRack-mount Automatic Transfer Switch (ATS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e1U, 19-inch rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric); 5-year extended warranty available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connections\u003c\/td\u003e\n\u003ctd\u003eTwo (2) IEC 60320 C14 inlets, 10 A 2P+E (Source A and Source B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e207 to 253 V (±10% of nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Current\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003ctd\u003eNot fitted (without circuit breaker); Schneider's datasheet calls for external 16 A facility branch protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Cords\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric as supplied - ask us to quote a pair of C13-to-C14 input cords with the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eTwelve (12) IEC 60320 C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Outlet\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e10 A overall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Capacity\u003c\/td\u003e\n\u003ctd\u003e2,000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum (high sensitivity); 12 ms maximum (low sensitivity); typical total transfer 8 to 12 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Technology\u003c\/td\u003e\n\u003ctd\u003eBreak-before-make relay switching; sources may be up to 180 degrees out of phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunications \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management Card\u003c\/td\u003e\n\u003ctd\u003eNetwork Management Card 3 (NMC3) integrated as standard; the NMC\/display module is field-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Port\u003c\/td\u003e\n\u003ctd\u003eGigabit Ethernet (10\/100\/1000) with link status LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interfaces\u003c\/td\u003e\n\u003ctd\u003eWeb UI (HTTP\/HTTPS), Command Line Interface (SSH\/SCP, Telnet), SNMP v1 and v3 with traps, Modbus TCP, FTP, Syslog, e-mail notification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Platform\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure IT compatible (alerts and control for one or many ATS units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Port Sharing\u003c\/td\u003e\n\u003ctd\u003eLink A and Link B ports: up to 32 AP44XXA Rack ATS units share one network connection and one IP address; one unit acts as host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003eMicro-USB for local CLI access (cable not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003eUSB-A for firmware upgrade from a USB drive and for the optional APC AP9834 Wi-Fi USB device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Sensor Port\u003c\/td\u003e\n\u003ctd\u003eUniversal I\/O port for the optional AP9335T temperature sensor or AP9335TH temperature\/humidity sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Display\u003c\/td\u003e\n\u003ctd\u003eColour LCD rotating through four default screens: Source A and B voltage and frequency, load per bank and total load in amps, alarm status, preferred source; Home\/Down\/Select buttons; backlight off after 10 minutes of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource Preference\u003c\/td\u003e\n\u003ctd\u003eSelectable - Source A, Source B, or no preference, from the front panel or remotely\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Sensitivity\u003c\/td\u003e\n\u003ctd\u003eSelectable high or low; up to three configurable transfer ranges (one active at a time) and a frequency deviation setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcurrent Users\u003c\/td\u003e\n\u003ctd\u003eUp to four users logged in simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware\u003c\/td\u003e\n\u003ctd\u003eFlash-upgradeable over the network or from a USB drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e43.7 x 431.8 x 236.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e3.93 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003eNot published consistently by Schneider Electric - ask us for the carton weight before freight booking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 15,240 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards (as printed by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003eEN 55022 Class A; FCC Part 15 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS \/ REACh\u003c\/td\u003e\n\u003ctd\u003eEU RoHS compliant; REACh declaration available from Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Load Planning\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Twelve IEC C13 outlets accept any standard IEC C14 equipment cord, which covers essentially all rack-mount switches, routers, firewalls, NAS appliances and 1U servers. There are no C19 outlets on this model, so a device needing a 16 A C20 inlet - a large blade chassis or a high-draw storage shelf - needs the \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423A\u003c\/a\u003e or \u003ca href=\"\/products\/apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424\"\u003eAP4424A\u003c\/a\u003e instead.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLoad planning.\u003c\/strong\u003e The AP4421A is rated at 10 A and 2,000 VA. Size the connected load against that ceiling rather than the outlet count - twelve outlets does not mean twelve full-draw servers. Work from the nameplate current of your equipment and leave headroom for inrush at power-on. Both feeds must be capable of carrying the entire load on their own, because in a failover one of them will. The unit has no internal circuit breaker; Schneider's datasheet asks for 16 A facility branch protection upstream of each source.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e 1U high, 431.8 mm wide and only 236.2 mm deep, so it mounts in shallow wall-mount comms cabinets as well as full-depth server racks. The 1U rack-mount bracket kit, screws, cage nuts and clip-on nuts are supplied in the box. Front and rear rail segments and a cord retention bracket are not included.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeeding it.\u003c\/strong\u003e Both inlets are IEC C14, so each source needs a C13-to-C14 cord - tell us and we will quote a pair of input cords with the unit. For the redundancy to be real the two sources must be genuinely independent: two separate UPS units, or one UPS feed and one direct mains feed on a different breaker. Two cords into the same PDU on the same breaker gives you no protection at all.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eManagement.\u003c\/strong\u003e The AP4421A carries Schneider's Network Management Card 3 as standard - there is no SmartSlot to populate and no card to buy. You get a Gigabit Ethernet port, a secure Web UI over HTTP\/HTTPS, a CLI over SSH, SNMP v1 and v3 with traps, Modbus TCP for a building management system, Syslog and e-mail alerts, and EcoStruxure IT integration. The NMC\/display module can be swapped in the field, so a damaged card is a spare-part exchange rather than a whole-unit return. The micro-USB console cable is not in the box.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental monitoring.\u003c\/strong\u003e The Universal I\/O port accepts the optional AP9335T temperature sensor or the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH temperature and humidity sensor\u003c\/a\u003e, so a comms cabinet with no other monitoring can report rack temperature through the same IP address as its power switching. Thresholds and alarms are set in the same Web UI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMany units, one IP.\u003c\/strong\u003e With Link A and Link B on the front panel, up to 32 AP44XXA-series Rack ATS units can be chained so that one network connection serves them all. One unit is the host; the rest appear under it in the Web UI and in SNMP. \u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; NetShelter Rack ATS Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC NetShelter Rack ATS (AP4421A)\u003c\/li\u003e\n\u003cli\u003e1U rack-mount bracket kit\u003c\/li\u003e\n\u003cli\u003ePhillips screws (10-32 x 0.5 in), cage nuts and clip-on nuts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInput power cords: the AP4421A has C14 inlets, so budget a C13-to-C14 cord for each source and ask us to include them on the quotation. A micro-USB cable for the console port is not included; any standard micro-USB data cable will do. Front and rear rail segments and a cord retention bracket are optional accessories and are not in the box.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eNetShelter Rack ATS Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP4421A (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 10 A, 2,000 VA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2 x IEC C14 inlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(12) C13\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3,700 VA\u003c\/td\u003e\n\u003ctd\u003e2 x IEC C20 inlets\u003c\/td\u003e\n\u003ctd\u003e(8) C13, (1) C19\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424\"\u003eAP4424A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7,400 VA\u003c\/td\u003e\n\u003ctd\u003e2 x IEC 60309 32 A\u003c\/td\u003e\n\u003ctd\u003e(16) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335TH\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAPC Temperature \u0026amp; Humidity Sensor\u003c\/a\u003e - plugs into the Universal I\/O port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335T\u003c\/td\u003e\n\u003ctd\u003eAPC Temperature Sensor - plugs into the Universal I\/O port; ask us for availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9834\u003c\/td\u003e\n\u003ctd\u003eAPC Wi-Fi USB device for cable-free setup and management via the USB-A port; ask us for availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eSchneider Electric hosts the official documentation for the AP44XXA-series Rack ATS. The links below are the document landing pages and product page that resolve to the correct part number. Links open in a new tab.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct overview and specifications\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-91720_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eNetShelter Rack ATS AP4421A Overview and Specifications (990-91720_EN)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-91718_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eRack ATS with Network Management Card 3 User Guide AP44XXA (990-91718_EN)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical brochure\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/sg\/en\/download\/document\/AP44xxA_Technical_Brochure\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC NetShelter Rack ATS Fifth Generation AP44xxA Series Technical Brochure\u003c\/a\u003e — Singapore site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric product page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/us\/en\/product\/AP4421A\/apc-netshelter-rack-automatic-transfer-switch-1u-10a-230v-c14-in-12-c13-out-50-60hz\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC AP4421A on se.com\u003c\/a\u003e — Schneider Electric US site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eSchneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eAP4421A\u003c\/strong\u003e and we will send you the current PDF datasheet and user guide directly.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP4421A\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat does a Rack ATS actually do, and how is it different from a UPS?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA Rack ATS switches between two power sources; a UPS stores energy. The AP4421A has no battery and cannot ride through an outage that hits both feeds at once - if Source A and Source B both fail, the load drops. Its job is to give single-corded equipment the same dual-feed resilience that dual-PSU equipment already has. In a well-designed rack the ATS sits downstream of a UPS on at least one of its two inputs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes the AP4421A have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider states this plainly in the AP44XXA user guide (990-91718): the Rack ATS does not include power surge protection, and it recommends connecting each Rack ATS source to a double-conversion on-line UPS. Claims of surge suppression against this part are incorrect. If surge and dip protection is what you actually need, an on-line UPS such as the Smart-UPS SRT range in front of the ATS is the right answer, and it also gives the ATS a genuinely independent second source.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs network management built in, or do I need to buy a card?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBuilt in. The AP4421A ships with Network Management Card 3 integrated - Gigabit Ethernet, Web UI over HTTP\/HTTPS, SSH, SNMP v1 and v3, Modbus TCP and EcoStruxure IT support are all standard. You do not buy a card for it. If the module is ever damaged it can be replaced in the field rather than sending the whole switch away.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan it monitor rack temperature and humidity?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes, with an optional sensor. Plug an AP9335T (temperature) or \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH (temperature and humidity)\u003c\/a\u003e into the Universal I\/O port and the readings, thresholds and alarms appear in the same Web UI and SNMP tree as the power data. No NetBotz appliance is needed for a single-cabinet site.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat does \"manage up to 32 ATS from one IP address\" mean in practice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEach AP44XXA-series unit has Link A and Link B ports. Chain up to 32 units through those ports, connect only the host unit to your network, and every unit in the group is visible and configurable through that one IP address. It saves a switch port and an address per cabinet and keeps the whole estate under one login.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow fast does it transfer, and will my servers notice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA maximum of 10 ms on the high sensitivity setting, 12 ms on low sensitivity, with Schneider quoting a typical total transfer of 8 to 12 ms. That is inside the hold-up time of a normal server or network power supply, so equipment generally rides through without restarting. High sensitivity reacts sooner to a marginal source; low sensitivity tolerates more deviation before acting, which is useful when a generator feed would otherwise make the unit transfer more often than you want. The two sources may be up to 180 degrees out of phase.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does the AP4421A differ from the AP4421 it replaces?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe electrical side is unchanged: same 10 A, 230 V rating, same inlet type and the same outlet configuration, so the AP4421A drops into an existing AP4421 installation without rewiring. What Schneider changed is the management module. The AP4421A moves from Network Management Card 2 to Network Management Card 3, and that card and its display are now field-replaceable. It adds a Universal I\/O port for an AP9335T or AP9335TH sensor, Link A and Link B ports for Network Port Sharing of up to 32 units on one IP address, Gigabit Ethernet in place of 10\/100, a colour LCD, a micro-USB console port instead of the old RJ12 serial lead, a USB-A port for firmware upgrade and the AP9834 Wi-Fi device, Modbus TCP, updated security (secured interfaces and a stricter password policy) and EcoStruxure IT integration. The standard warranty stays at 2 years.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does it compare with the AP4423A?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSame chassis, same NMC3 management, different power class. The AP4421A is 10 A and 2,000 VA with C14 inlets and twelve C13 outlets. The \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423A\u003c\/a\u003e is 16 A and 3,700 VA with C20 inlets and trades four C13 outlets for a C19 - eight C13 plus one C19 - to serve a single higher-draw device. If everything in the cabinet is C14-corded and the total draw is under 10 A, the AP4421A is the correct choice. Note that the 32 A \u003ca href=\"\/products\/apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424\"\u003eAP4424A\u003c\/a\u003e is 2U, not 1U, so do not budget rack space for one and order the other.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Rack ATS AP4421A sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs the AP4421A with a 2-year manufacturer warranty, and a 5-year extended warranty is offered by Schneider - ask us to quote it with the unit.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879373906084,"sku":"AP4421A","price":1825.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_0201317a-de3d-4cb8-811f-1a504bc32ec0.jpg?v=1789701457"},{"product_id":"apc-easy-ups-bvx-900va","title":"APC Easy UPS BVX 900VA, 230V, AVR, Universal Sockets","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Easy UPS BVX 900VA, 230V, AVR, Universal Sockets (BVX900LI-MS) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003eNo Longer Available. New or Similar items below:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/apc-easy-ups-700va-tower-230v-2-universal-outlets\"\u003eAPC Easy UPS BVG 700VA Tower, 230V, 2 Universal Outlets, AVR (BVG700I-MSX)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/apc-easy-ups-1200va-tower-230v-4-universal-outlets\"\u003eAPC Easy UPS BVG 1200VA Tower, 230V, 4 Universal Outlets, AVR (BVG1200I-MSX)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/apc-easy-ups-1600va-tower-230v-4-universal-outlets\"\u003eAPC Easy UPS BVG 1600VA Tower, 230V, 4 Universal Outlets, AVR (BVG1600I-MSX)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/apc-easy-ups-2200va-tower-230v-4-universal-outlets\"\u003eAPC Easy UPS BVG 2200VA Tower, 230V, 4 Universal Outlets, AVR (BVG2200I-MSX)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAPC BVX900LI-MS — 900 VA \/ 480 W Backup Power for Singapore Offices\u003c\/h3\u003e\n\u003cp\u003eThe APC Easy UPS BVX900LI-MS is a line-interactive UPS with automatic voltage regulation, rated 900 VA \/ 480 W and fitted with two universal sockets and one IEC C13, all battery-backed. Its universal sockets take Singapore three-pin plugs directly, so there are no adapters cluttering the back of the desk. AVR is the feature that earns its keep here: it corrects the sags and swells that come with an ageing building riser or a heavy air-conditioning load without discharging the battery, which means the battery is still full when you actually need it.\u003c\/p\u003e\n\u003ch3\u003e230 V, 50 Hz Mains Protection Built for Singapore Conditions\u003c\/h3\u003e\n\u003cp\u003eSingapore's mains is nominally 230 V at 50 Hz and PUB's grid is among the most reliable anywhere, but reliable is not the same as clean. Lightning is frequent, lifts and chillers starting on the same riser pull the voltage down, and older buildings sag noticeably at the far end of a long run. The BVX900LI-MS's automatic voltage regulation corrects those conditions electronically and keeps the output within tolerance without switching to battery, so the battery is preserved for genuine outages. When the supply does fail, transfer happens in 6 ms typical, 10 ms maximum — far quicker than a computer power supply can notice.\u003c\/p\u003e\n\u003ch3\u003eUser-Replaceable Battery and Humidity Considerations\u003c\/h3\u003e\n\u003cp\u003eThe BVX900LI-MS runs from a maintenance-free sealed lead-acid battery that you can replace yourself when it reaches the end of its life. The correct cartridge is the APC RBC17, which SourceIT stocks: \u003ca href=\"\/products\/apc-replacement-battery-cartridge-17-rbc17\"\u003eAPC Replacement Battery Cartridge RBC17\u003c\/a\u003e. Battery life in Singapore is genuinely shorter than in temperate markets: sustained heat and humidity accelerate the chemistry, and a unit kept in an un-airconditioned store room or a closed cabinet will age faster than one on an open desk. Giving the vents clear air is the single most effective thing you can do to get full service life out of it, and treating the cartridge as a scheduled consumable rather than waiting for a failure is the difference between a planned five-minute swap and an unprotected server room.\u003c\/p\u003e\n\u003ch3\u003eWhere This Model Fits — SME Office, Home Office and Comms Cabinet\u003c\/h3\u003e\n\u003cp\u003eAt 480 W of usable output across two universal sockets and one IEC C13, all battery-backed, the BVX900LI-MS suits a desktop and monitor, a router and ONT, a small NAS, a point-of-sale terminal or the network gear at the bottom of a comms cabinet. It is a tower unit, not a rack product, and there is no rail kit for it. If your requirement involves a rack, a server with an active-PFC power supply, SNMP monitoring or extended runtime, that is Smart-UPS territory and SourceIT will point you at the right SMC, SMT or SMX model instead of overselling this one. Everything we supply comes with local Singapore warranty and a GST invoice.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC BVX900LI-MS Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eBVX900LI-MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS, 900VA, Tower, 230V, 2 Universal + 1 IEC C13 outlets, AVR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEasy UPS BVX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Voltage Regulation (AVR)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Display\u003c\/td\u003e\n\u003ctd\u003eLED status display (on line \/ on battery) plus audible alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupplied by SourceIT Pte Ltd with GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e900 VA \/ 480 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±1 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eStepped approximation to a sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e6 ms typical, 10 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003e2 × universal sockets and 1 × IEC 60320 C13, all with battery backup and surge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Line Protection\u003c\/td\u003e\n\u003ctd\u003eNot fitted on this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed lead-acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Nominal Voltage\u003c\/td\u003e\n\u003ctd\u003e12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e9.0 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPC Replacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eRBC17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e8 hours typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Replacement\u003c\/td\u003e\n\u003ctd\u003eUser-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at 240 W (50% load)\u003c\/td\u003e\n\u003ctd\u003eapproximately 6.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at 70% load\u003c\/td\u003e\n\u003ctd\u003emore than 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003eNo data or management port, and no shutdown software is supplied with this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold Start\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm high × 120 mm wide (depth not published by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eUPS unit and user manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eEvery figure in these tables is taken from Schneider Electric's published documentation for this exact part number. Where Schneider does not publish a value, or where two of its own documents disagree, the row is left out rather than estimated — ask SourceIT and we will confirm it with the distributor.\u003c\/p\u003e\n\u003cp\u003eSchneider Electric does not publish a downloadable product data sheet for the BVX900LI-MS, so several rows that appear on its sibling models — input voltage window, surge energy rating, humidity range, audible noise and the certification list — are deliberately left out here rather than copied across from the 700 VA or 1200 VA sheet. The two Schneider documents that do cover this model also disagree on its depth (335 mm in the brochure, 355 mm in the user manual), so depth is omitted. Ask SourceIT if you need any of these figures confirmed for a tender or a rack drawing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe BVX900LI-MS provides 2 × universal sockets and 1 × IEC 60320 C13, all with battery backup and surge protection. Its usable output is \u003cstrong\u003e480 watts\u003c\/strong\u003e — that is the number to size against, not the 900 VA headline. Add up the wattage of everything you intend to protect and keep the total comfortably below 480 W so the unit is not running at its limit every day.\u003c\/p\u003e\n\u003cp\u003eThe universal sockets accept Singapore three-pin BS 1363 plugs as well as the common two-pin styles, so no adapter is needed, and every socket on this model carries battery backup and surge protection. The IEC C13 socket takes a standard kettle-style computer or monitor lead directly.\u003c\/p\u003e\n\u003ch4\u003eRuntime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e240 W (50% load)\u003c\/td\u003e\n\u003ctd\u003eapproximately 6.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e70% load\u003c\/td\u003e\n\u003ctd\u003emore than 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eRuntime falls away sharply as load rises, so these published points are a guide rather than a promise for your particular equipment. A UPS in this class is sized to ride through the short dips and to give you a clean shutdown, not to keep a desk running through a long outage. If you need a specific number of minutes at a specific load, send SourceIT your equipment list and we will size it properly.\u003c\/p\u003e\n\u003ch4\u003eBattery and replacement cartridge\u003c\/h4\u003e\n\u003cp\u003eThe BVX900LI-MS takes the \u003cstrong\u003eAPC RBC17\u003c\/strong\u003e replacement battery cartridge, which SourceIT stocks: \u003ca href=\"\/products\/apc-replacement-battery-cartridge-17-rbc17\"\u003eAPC Replacement Battery Cartridge RBC17\u003c\/a\u003e. The battery is user-replaceable, so a cartridge swap does not require a service visit. In Singapore's heat and humidity a UPS battery generally reaches the end of its useful life before the electronics do, so budget for a cartridge as a consumable rather than a fault.\u003c\/p\u003e\n\u003ch4\u003eManagement and monitoring\u003c\/h4\u003e\n\u003cp\u003eConnectivity: No data or management port, and no shutdown software is supplied with this model. Schneider Electric lists no SmartSlot bay or network management card option for this range. If you need SNMP monitoring, EcoStruxure IT integration or scripted shutdown across several machines, the Smart-UPS SMC and SMT ranges are the right place to look and SourceIT can quote them.\u003c\/p\u003e\n\u003ch4\u003eSiting it\u003c\/h4\u003e\n\u003cp\u003eThis is a tower unit measuring 160 mm high and 120 mm wide, with depth not published by Schneider Electric, weighing 6 kg, and it is rated for 0 to 40 °C. It is designed to stand on or under a desk, on a shelf, or on the floor of a comms cabinet — it is not a rack-mount product and no rail kit is available for it. Leave clear air around the vents; an enclosed cupboard in an un-airconditioned room will shorten the battery's life more than anything else you can do to it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS BVX Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cp\u003eUPS unit and user manual.\u003c\/p\u003e\n\u003ch4\u003eEasy UPS BVX series — ordering information\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-bvx-700va-230v-avr-bvx700lui-ms\"\u003eBVX700LUI-MS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e700 VA \/ 360 W — 2 × universal (both battery-backed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBVX900LI-MS (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e900 VA \/ 480 W — 2 × universal + 1 × IEC C13 (all battery-backed)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-bvx-1200va\"\u003eBVX1200LI-MS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 VA \/ 650 W — 4 × universal + 1 × IEC C13 (all battery-backed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eThe three BVX models differ in more than capacity: the socket mix changes at every step, and only the 700 VA model carries a USB charging port. Check the outlet row in the specification table before ordering.\u003c\/p\u003e\n\u003ch4\u003eReplacement battery cartridges\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-17-rbc17\"\u003eAPC RBC17\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for this unit. Also fits: BK650EI, BK650-AS.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eRelated equipment\u003c\/h4\u003e\n\u003cp\u003eThese are standalone tower units, and Schneider Electric lists no rail kit, external battery pack or network management card option for any of them. If your requirement has grown past that — rack mounting, SNMP monitoring, extended runtime, or a pure sine wave output for an active-PFC server power supply — the APC Smart-UPS SMC, SMT and SMX ranges are the step up, and SourceIT stocks them with the same local warranty and GST invoicing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/BVX900LI-MS\/apc-easy-ups-900va-tower-230v-2-universal-+-1-iec-c13-outlets-avr\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for the BVX900LI-MS\u003c\/a\u003e — the official product record. This is the Singapore record.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/in\/en\/download\/document\/SPD_BU-UM-990-6292_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Easy UPS BVX User Manual, 230 V ASEAN models (Schneider Electric, SPD_BU-UM-990-6292_EN)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eEach link above was checked and resolves at the time of writing. Schneider Electric hosts its documents through a redirect service that sometimes serves a different model's file; where that happened during our checks we have linked the document record page instead of the direct PDF, so you always land on the correct document for this product. If you need a copy of the data sheet for a tender submission, email SourceIT and we will send the current revision.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC BVX900LI-MS\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between 900 VA and 480 W, and which should I size against?\u003c\/h4\u003e\n\u003cp\u003eSize against the watts. VA is apparent power and W is real power; for this class of UPS the watt figure is the honest ceiling on what you can actually run. The BVX900LI-MS is rated \u003cstrong\u003e900 VA \/ 480 W\u003c\/strong\u003e. Add up the wattage on the labels or power supplies of everything you want to protect and keep the total below 480 W with room to spare. A modern desktop and monitor typically draw well under 200 W together, but a laser printer can spike far higher, which is one reason printers should not be on a UPS at all.\u003c\/p\u003e\n\u003ch4\u003eHow long will it run during a power cut?\u003c\/h4\u003e\n\u003cp\u003eIt depends entirely on your load, which is why the published points in the Compatibility \u0026amp; Runtime section are given at stated wattages rather than as a single number. Lighter loads run considerably longer than heavy ones. In practice a UPS of this size is bought to ride out the brief dips and momentary cuts that come with thunderstorms on the Singapore grid, and to give you a few minutes to save your work and shut down properly — not to keep working through a long outage.\u003c\/p\u003e\n\u003ch4\u003eWhat do the \"LI\", \"LUI\" and \"-MS\" suffixes mean? Is this a lithium battery?\u003c\/h4\u003e\n\u003cp\u003eIt is \u003cstrong\u003enot\u003c\/strong\u003e a lithium battery — that is a common misreading of the part number. All three BVX models use a sealed lead-acid (VRLA) battery, confirmed in Schneider Electric's brochure, data sheets and user manual. The letters denote the build: \"LI\" is the international IEC build, \"LUI\" is the same with a USB charging port added, and \"-MS\" is the ASEAN build with universal sockets. If you specifically want lithium-ion, that is the Smart-UPS Ultra and SRTL ranges, which SourceIT can quote separately.\u003c\/p\u003e\n\u003ch4\u003eIs the output a pure sine wave? Will it work with an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eNo — the BVX900LI-MS produces a \u003cstrong\u003estepped approximation to a sine wave\u003c\/strong\u003e on battery, which is what Schneider Electric's documentation states for this model. That is entirely normal for this class of UPS and it is fine for the great majority of desktops, monitors, routers, modems, NAS boxes and point-of-sale terminals. It is worth knowing, though, that some high-efficiency power supplies with active power factor correction — typically in servers and higher-end workstations — can be fussy about a stepped waveform and may shut down or refuse to transfer. If you are protecting a server or an active-PFC workstation, ask SourceIT about the APC Smart-UPS SMC or SMT range, which produces a true sine wave output.\u003c\/p\u003e\n\u003ch4\u003eWhich replacement battery does it take, and can I change it myself?\u003c\/h4\u003e\n\u003cp\u003eYes. The correct cartridge is the \u003cstrong\u003eAPC RBC17\u003c\/strong\u003e, which SourceIT stocks: \u003ca href=\"\/products\/apc-replacement-battery-cartridge-17-rbc17\"\u003eAPC Replacement Battery Cartridge RBC17\u003c\/a\u003e. It is user-replaceable, so you do not need a service call — follow the instructions in the user manual, and take the old cartridge to a proper battery recycling point rather than putting it in the bin.\u003c\/p\u003e\n\u003ch4\u003eHow does this compare with the Easy UPS BVG models?\u003c\/h4\u003e\n\u003cp\u003eThe BVG range is the current Easy UPS line that SourceIT stocks alongside the BVX. The practical differences are the socket mix and the plug: BVG models arrive with a moulded British three-pin plug and universal sockets throughout, while the BVX models use an IEC C14 inlet and mix universal sockets with an IEC C13. If you are choosing between them today, the BVG is the range with current supply — see \u003ca href=\"\/products\/apc-easy-ups-1200va-tower-230v-4-universal-outlets\"\u003eBVG1200I-MSX\u003c\/a\u003e and \u003ca href=\"\/products\/apc-easy-ups-1600va-tower-230v-4-universal-outlets\"\u003eBVG1600I-MSX\u003c\/a\u003e for the closest equivalents by capacity. SourceIT is happy to advise on a like-for-like swap.\u003c\/p\u003e\n\u003ch4\u003eIs this suitable for a server?\u003c\/h4\u003e\n\u003cp\u003eA UPS in this class is designed for desktops, monitors, routers, modems, NAS boxes, point-of-sale terminals and small office equipment. It is not the right protection for a production server: there is no network management card option, no SmartSlot, no extended-runtime battery pack, and the output is a stepped approximation rather than a true sine wave, which some server power supplies will not accept. For a server, a comms cabinet or anything in a rack, ask SourceIT about the APC Smart-UPS SMC, SMT and SMX ranges.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC BVX900LI-MS sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the BVX900LI-MS with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/UTKl_tMIaSY\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879381967012,"sku":"BVX900LI-MS","price":175.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-easy-ups-bvx-900va-230v-avr-universal-sockets-pnbvx900li-ms-2-year-local-warranty-427049.jpg?v=1654153905"},{"product_id":"apc-easy-ups-bvx-1200va","title":"APC Easy UPS BVX 1200VA, 230V, AVR, Universal Sockets","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Easy UPS BVX 1200VA, 230V, AVR, Universal Sockets (BVX1200LI-MS) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003eNo Longer Available. New or Similar items below:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/apc-easy-ups-700va-tower-230v-2-universal-outlets\"\u003eAPC Easy UPS BVG 700VA Tower, 230V, 2 Universal Outlets, AVR (BVG700I-MSX)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/apc-easy-ups-1200va-tower-230v-4-universal-outlets\"\u003eAPC Easy UPS BVG 1200VA Tower, 230V, 4 Universal Outlets, AVR (BVG1200I-MSX)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/apc-easy-ups-1600va-tower-230v-4-universal-outlets\"\u003eAPC Easy UPS BVG 1600VA Tower, 230V, 4 Universal Outlets, AVR (BVG1600I-MSX)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/apc-easy-ups-2200va-tower-230v-4-universal-outlets\"\u003eAPC Easy UPS BVG 2200VA Tower, 230V, 4 Universal Outlets, AVR (BVG2200I-MSX)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAPC BVX1200LI-MS — 1200 VA \/ 650 W Backup Power for Singapore Offices\u003c\/h3\u003e\n\u003cp\u003eThe APC Easy UPS BVX1200LI-MS is a line-interactive UPS with automatic voltage regulation, rated 1200 VA \/ 650 W and fitted with four universal sockets and one IEC C13, all battery-backed. Its universal sockets take Singapore three-pin plugs directly, so there are no adapters cluttering the back of the desk. AVR is the feature that earns its keep here: it corrects the sags and swells that come with an ageing building riser or a heavy air-conditioning load without discharging the battery, which means the battery is still full when you actually need it.\u003c\/p\u003e\n\u003ch3\u003e230 V, 50 Hz Mains Protection Built for Singapore Conditions\u003c\/h3\u003e\n\u003cp\u003eSingapore's mains is nominally 230 V at 50 Hz and PUB's grid is among the most reliable anywhere, but reliable is not the same as clean. Lightning is frequent, lifts and chillers starting on the same riser pull the voltage down, and older buildings sag noticeably at the far end of a long run. The BVX1200LI-MS's automatic voltage regulation corrects those conditions electronically and keeps the output within tolerance without switching to battery, so the battery is preserved for genuine outages. When the supply does fail, transfer happens in 6 ms typical, 10 ms maximum — far quicker than a computer power supply can notice.\u003c\/p\u003e\n\u003ch3\u003eSurge Protection and Equipment Safety\u003c\/h3\u003e\n\u003cp\u003eThe BVX1200LI-MS carries a surge energy rating of 273 Joules, absorbing the transients that follow a nearby lightning strike or a large motor switching on the same circuit. Surge damage is cumulative and usually silent — equipment does not fail on the day, it fails months later — which is why the protection is worth having on equipment you would rather not replace.\u003c\/p\u003e\n\u003ch3\u003eUser-Replaceable Battery and Humidity Considerations\u003c\/h3\u003e\n\u003cp\u003eThe BVX1200LI-MS runs from a maintenance-free sealed lead-acid battery that you can replace yourself when it reaches the end of its life. Battery life in Singapore is genuinely shorter than in temperate markets: sustained heat and humidity accelerate the chemistry, and a unit kept in an un-airconditioned store room or a closed cabinet will age faster than one on an open desk. Giving the vents clear air is the single most effective thing you can do to get full service life out of it, and treating the cartridge as a scheduled consumable rather than waiting for a failure is the difference between a planned five-minute swap and an unprotected server room.\u003c\/p\u003e\n\u003ch3\u003eWhere This Model Fits — SME Office, Home Office and Comms Cabinet\u003c\/h3\u003e\n\u003cp\u003eAt 650 W of usable output across four universal sockets and one IEC C13, all battery-backed, the BVX1200LI-MS suits a desktop and monitor, a router and ONT, a small NAS, a point-of-sale terminal or the network gear at the bottom of a comms cabinet. It is a tower unit, not a rack product, and there is no rail kit for it. If your requirement involves a rack, a server with an active-PFC power supply, SNMP monitoring or extended runtime, that is Smart-UPS territory and SourceIT will point you at the right SMC, SMT or SMX model instead of overselling this one. Everything we supply comes with local Singapore warranty and a GST invoice.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC BVX1200LI-MS Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eBVX1200LI-MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS, 1200VA, Tower, 230V, 4 Universal + 1 IEC C13 outlets, AVR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEasy UPS BVX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Voltage Regulation (AVR)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Display\u003c\/td\u003e\n\u003ctd\u003eLED status display (on line \/ on battery) plus audible alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupplied by SourceIT Pte Ltd with GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e1200 VA \/ 650 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±1 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eStepped approximation to a sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e6 ms typical, 10 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003e4 × universal sockets and 1 × IEC 60320 C13, all with battery backup and surge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e273 Joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Line Protection\u003c\/td\u003e\n\u003ctd\u003eNot fitted on this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e140–300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±5 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet, 1.22 m detachable cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Factor\u003c\/td\u003e\n\u003ctd\u003e0.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed lead-acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Nominal Voltage\u003c\/td\u003e\n\u003ctd\u003e12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e9.0 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPC Replacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e8 hours typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Replacement\u003c\/td\u003e\n\u003ctd\u003eUser-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at 300 W (50% load)\u003c\/td\u003e\n\u003ctd\u003eapproximately 5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at 70% load\u003c\/td\u003e\n\u003ctd\u003eapproximately 3.2 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at 650 W (full load)\u003c\/td\u003e\n\u003ctd\u003eapproximately 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003eNo data or management port. Schneider's specification records this model as \"USB compatible: No\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold Start\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e190 × 140 × 390 mm (H × W × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e7.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e0–95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e40 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, CB (EN\/IEC 62040-1:2019\/A11:2021, EN\/IEC 62040-2:2006\/AC:2006, EN\/IEC 62040-2:2018)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eUPS unit and user manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarcode\u003c\/td\u003e\n\u003ctd\u003eSCC14 10731304404375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eEvery figure in these tables is taken from Schneider Electric's published documentation for this exact part number. Where Schneider does not publish a value, or where two of its own documents disagree, the row is left out rather than estimated — ask SourceIT and we will confirm it with the distributor.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe BVX1200LI-MS provides 4 × universal sockets and 1 × IEC 60320 C13, all with battery backup and surge protection. Its usable output is \u003cstrong\u003e650 watts\u003c\/strong\u003e — that is the number to size against, not the 1200 VA headline. Add up the wattage of everything you intend to protect and keep the total comfortably below 650 W so the unit is not running at its limit every day.\u003c\/p\u003e\n\u003cp\u003eThe universal sockets accept Singapore three-pin BS 1363 plugs as well as the common two-pin styles, so no adapter is needed, and every socket on this model carries battery backup and surge protection. The IEC C13 socket takes a standard kettle-style computer or monitor lead directly.\u003c\/p\u003e\n\u003ch4\u003eRuntime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e300 W (50% load)\u003c\/td\u003e\n\u003ctd\u003eapproximately 5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e70% load\u003c\/td\u003e\n\u003ctd\u003eapproximately 3.2 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e650 W (full load)\u003c\/td\u003e\n\u003ctd\u003eapproximately 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eRuntime falls away sharply as load rises, so these published points are a guide rather than a promise for your particular equipment. A UPS in this class is sized to ride through the short dips and to give you a clean shutdown, not to keep a desk running through a long outage. If you need a specific number of minutes at a specific load, send SourceIT your equipment list and we will size it properly.\u003c\/p\u003e\n\u003ch4\u003eBattery and replacement cartridge\u003c\/h4\u003e\n\u003cp\u003eThe BVX1200LI-MS takes the \u003cstrong\u003eAPC APCRBC175\u003c\/strong\u003e replacement battery cartridge. This part is not currently a stocked SourceIT line — contact us and we will source it. The battery is user-replaceable, so a cartridge swap does not require a service visit, and in Singapore's heat and humidity it should be budgeted as a consumable rather than treated as a fault.\u003c\/p\u003e\n\u003ch4\u003eManagement and monitoring\u003c\/h4\u003e\n\u003cp\u003eConnectivity: No data or management port. Schneider's specification records this model as \"USB compatible: No\". Schneider Electric lists no SmartSlot bay or network management card option for this range. If you need SNMP monitoring, EcoStruxure IT integration or scripted shutdown across several machines, the Smart-UPS SMC and SMT ranges are the right place to look and SourceIT can quote them.\u003c\/p\u003e\n\u003ch4\u003eSiting it\u003c\/h4\u003e\n\u003cp\u003eThis is a tower unit measuring 190 × 140 × 390 mm (H × W × D), weighing 7.5 kg, and it is rated for 0 to 40 °C. It is designed to stand on or under a desk, on a shelf, or on the floor of a comms cabinet — it is not a rack-mount product and no rail kit is available for it. Leave clear air around the vents; an enclosed cupboard in an un-airconditioned room will shorten the battery's life more than anything else you can do to it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS BVX Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cp\u003eUPS unit and user manual.\u003c\/p\u003e\n\u003ch4\u003eEasy UPS BVX series — ordering information\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-bvx-700va-230v-avr-bvx700lui-ms\"\u003eBVX700LUI-MS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e700 VA \/ 360 W — 2 × universal (both battery-backed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-bvx-900va\"\u003eBVX900LI-MS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e900 VA \/ 480 W — 2 × universal + 1 × IEC C13 (all battery-backed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBVX1200LI-MS (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1200 VA \/ 650 W — 4 × universal + 1 × IEC C13 (all battery-backed)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eThe three BVX models differ in more than capacity: the socket mix changes at every step, and only the 700 VA model carries a USB charging port. Check the outlet row in the specification table before ordering.\u003c\/p\u003e\n\u003ch4\u003eReplacement battery cartridges\u003c\/h4\u003e\n\u003cp\u003eThis model takes the APC APCRBC175 cartridge, which is not currently a stocked SourceIT line. Contact us and we will source it.\u003c\/p\u003e\n\u003ch4\u003eRelated equipment\u003c\/h4\u003e\n\u003cp\u003eThese are standalone tower units, and Schneider Electric lists no rail kit, external battery pack or network management card option for any of them. If your requirement has grown past that — rack mounting, SNMP monitoring, extended runtime, or a pure sine wave output for an active-PFC server power supply — the APC Smart-UPS SMC, SMT and SMX ranges are the step up, and SourceIT stocks them with the same local warranty and GST invoicing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/BVX1200LI-MS\/apc-easy-ups-1200va-tower-230v-4-universal-+-1-iec-c13-outlets-avr\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for the BVX1200LI-MS\u003c\/a\u003e — the official product record. This is the Singapore record.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/in\/en\/download\/document\/SPD_BU-UM-990-6292_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Easy UPS BVX User Manual, 230 V ASEAN models (Schneider Electric, SPD_BU-UM-990-6292_EN)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eEach link above was checked and resolves at the time of writing. Schneider Electric hosts its documents through a redirect service that sometimes serves a different model's file; where that happened during our checks we have linked the document record page instead of the direct PDF, so you always land on the correct document for this product. If you need a copy of the data sheet for a tender submission, email SourceIT and we will send the current revision.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC BVX1200LI-MS\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between 1200 VA and 650 W, and which should I size against?\u003c\/h4\u003e\n\u003cp\u003eSize against the watts. VA is apparent power and W is real power; for this class of UPS the watt figure is the honest ceiling on what you can actually run. The BVX1200LI-MS is rated \u003cstrong\u003e1200 VA \/ 650 W\u003c\/strong\u003e. Add up the wattage on the labels or power supplies of everything you want to protect and keep the total below 650 W with room to spare. A modern desktop and monitor typically draw well under 200 W together, but a laser printer can spike far higher, which is one reason printers should not be on a UPS at all.\u003c\/p\u003e\n\u003ch4\u003eHow long will it run during a power cut?\u003c\/h4\u003e\n\u003cp\u003eIt depends entirely on your load, which is why the published points in the Compatibility \u0026amp; Runtime section are given at stated wattages rather than as a single number. Lighter loads run considerably longer than heavy ones. In practice a UPS of this size is bought to ride out the brief dips and momentary cuts that come with thunderstorms on the Singapore grid, and to give you a few minutes to save your work and shut down properly — not to keep working through a long outage.\u003c\/p\u003e\n\u003ch4\u003eWhat do the \"LI\", \"LUI\" and \"-MS\" suffixes mean? Is this a lithium battery?\u003c\/h4\u003e\n\u003cp\u003eIt is \u003cstrong\u003enot\u003c\/strong\u003e a lithium battery — that is a common misreading of the part number. All three BVX models use a sealed lead-acid (VRLA) battery, confirmed in Schneider Electric's brochure, data sheets and user manual. The letters denote the build: \"LI\" is the international IEC build, \"LUI\" is the same with a USB charging port added, and \"-MS\" is the ASEAN build with universal sockets. If you specifically want lithium-ion, that is the Smart-UPS Ultra and SRTL ranges, which SourceIT can quote separately.\u003c\/p\u003e\n\u003ch4\u003eIs the output a pure sine wave? Will it work with an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eNo — the BVX1200LI-MS produces a \u003cstrong\u003estepped approximation to a sine wave\u003c\/strong\u003e on battery, which is what Schneider Electric's documentation states for this model. That is entirely normal for this class of UPS and it is fine for the great majority of desktops, monitors, routers, modems, NAS boxes and point-of-sale terminals. It is worth knowing, though, that some high-efficiency power supplies with active power factor correction — typically in servers and higher-end workstations — can be fussy about a stepped waveform and may shut down or refuse to transfer. If you are protecting a server or an active-PFC workstation, ask SourceIT about the APC Smart-UPS SMC or SMT range, which produces a true sine wave output.\u003c\/p\u003e\n\u003ch4\u003eWhich replacement battery does it take, and can I change it myself?\u003c\/h4\u003e\n\u003cp\u003eThe correct cartridge is the \u003cstrong\u003eAPC APCRBC175\u003c\/strong\u003e. It is user-replaceable, so you do not need a service call. This part is not currently a stocked SourceIT line — contact us and we will source it for you rather than risk you ordering a cartridge that does not fit.\u003c\/p\u003e\n\u003ch4\u003eHow does this compare with the Easy UPS BVG models?\u003c\/h4\u003e\n\u003cp\u003eThe BVG range is the current Easy UPS line that SourceIT stocks alongside the BVX. The practical differences are the socket mix and the plug: BVG models arrive with a moulded British three-pin plug and universal sockets throughout, while the BVX models use an IEC C14 inlet and mix universal sockets with an IEC C13. If you are choosing between them today, the BVG is the range with current supply — see \u003ca href=\"\/products\/apc-easy-ups-1200va-tower-230v-4-universal-outlets\"\u003eBVG1200I-MSX\u003c\/a\u003e and \u003ca href=\"\/products\/apc-easy-ups-1600va-tower-230v-4-universal-outlets\"\u003eBVG1600I-MSX\u003c\/a\u003e for the closest equivalents by capacity. SourceIT is happy to advise on a like-for-like swap.\u003c\/p\u003e\n\u003ch4\u003eIs this suitable for a server?\u003c\/h4\u003e\n\u003cp\u003eA UPS in this class is designed for desktops, monitors, routers, modems, NAS boxes, point-of-sale terminals and small office equipment. It is not the right protection for a production server: there is no network management card option, no SmartSlot, no extended-runtime battery pack, and the output is a stepped approximation rather than a true sine wave, which some server power supplies will not accept. For a server, a comms cabinet or anything in a rack, ask SourceIT about the APC Smart-UPS SMC, SMT and SMX ranges.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC BVX1200LI-MS sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the BVX1200LI-MS with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/UTKl_tMIaSY\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":41879382720676,"sku":"BVX1200LI-MS","price":205.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-easy-ups-bvx-1200va-230v-avr-universal-sockets-pnbvx1200li-ms-2-year-local-warrant-495515.jpg?v=1654153903"},{"product_id":"apc-back-ups-pro-1500va-865w-tower-230v-10x-iec-c13-outlets-avr-lcd-br1500gi","title":"APC Back-UPS Pro 1500VA, 10xC13, AVR, LCD","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Back-UPS Pro 1500VA, 10xC13, AVR, LCD (BR1500GI) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eAPC BR1500GI 1500 VA \/ 865 W UPS for Singapore's 230V \/ 50Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC BR1500GI is a 1500 VA \/ 865 W line-interactive UPS with stepped-approximation output, built for 230 V, 50 Hz supplies — exactly what Singapore's PUB grid delivers. It rides through the short dips, brownouts and momentary interruptions that follow an afternoon thunderstorm, and its Automatic Voltage Regulation corrects high and low mains voltage \u003cem\u003ewithout\u003c\/em\u003e going to battery, so the cells are not cycled every time the supply wanders. Output is 10 x C13 — 5 battery-backed, 5 surge-only, plus 2 jumper cords.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStepped-Approximation Output — Check Your PSU Before You Order\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BR1500GI produces a stepped approximation to a sinewave on battery, which is what the Schneider data sheet states for this exact part number. That is entirely suitable for most desktop PCs, routers, switches, NVRs, POS terminals and comms-cabinet gear. If the load is an active-PFC ATX power supply that is fussy about waveform, specify a sine wave model instead — in the Back-UPS Pro BR range that is the \u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e or \u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e. We would rather tell you that up front than take the return.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutlets, Runtime and Battery Life in a Humid Climate\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOutlets are 5 x IEC 60320 C13 (battery backup and surge protection) plus 5 x IEC 60320 C13 (surge protection only) and 2 IEC jumper cords. The surge-only outlets are there for printers, monitors and chargers that do not need backup but do need protection — keeping them off the battery bank is what buys you runtime on the equipment that matters. The battery is a sealed maintenance-free lead-acid (VRLA) cartridge with a 3 to 5 year expected service life. Singapore's heat and humidity are hard on VRLA cells, so plan on a cartridge change inside that window rather than at the end of it; the replacement part is \u003ca href=\"\/products\/apc-replacement-battery-cartridge-124-apcrbc124\"\u003eAPCRBC124\u003c\/a\u003e. Schneider does not publish a runtime-versus-load table for the BR1500GI, so we do not print one — runtime depends entirely on how much of the 865 W you actually draw. Tell us your load in watts and we will size it for you.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSME Office, Home Office and Comms-Cabinet Duty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis is a tower unit at 301 mm (H) x 112 mm (W) x 380 mm (D), 12.7 kg — it sits on a desk, under a counter or on the floor of a comms cupboard rather than in a rack, so it costs you no rack U. Everything SourceIT ships is local Singapore stock with a GST invoice and local warranty support — no grey imports, no chasing an overseas RMA.\u003c\/p\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC BR1500GI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eEvery figure below is taken from the Schneider Electric product page (United Kingdom) and the APC BR1500GI product data sheet as carried by two independent distributor mirrors that agree. Where Schneider does not publish a value for this exact part number, the row is left out rather than filled in from a similar model.\u003c\/p\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eBR1500GI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro, 1500VA\/865W, Tower, 230V, 10x IEC C13 outlets, AVR, LCD, User Replaceable Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro BR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive with Automatic Voltage Regulation (AVR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e1500 VA \/ 865 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003eRepair or replace; Schneider states 2 years for the rest of the world and 3 years inside the European Community, so Singapore takes the 2-year term\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupported locally by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e865 W \/ 1500 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 1 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform (on battery)\u003c\/td\u003e\n\u003ctd\u003eStepped approximation to a sinewave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003e5 x IEC 60320 C13 (battery backup and surge protection) plus 5 x IEC 60320 C13 (surge protection only) and 2 IEC jumper cords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e10 ms typical, 12 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e441 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Filtering\u003c\/td\u003e\n\u003ctd\u003eFull-time multi-pole noise filtering, 10% of IEEE surge let-through, instantaneous response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e156 to 300 V, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 3 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e10 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003eAutomatic Voltage Regulation (AVR) — corrects high and low mains voltage without switching to battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed maintenance-free lead-acid (VRLA), user replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e9.0 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Rating\u003c\/td\u003e\n\u003ctd\u003e216 VAh (187 VAh usable runtime rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e8 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Battery Life\u003c\/td\u003e\n\u003ctd\u003e3 to 5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Runtime\u003c\/td\u003e\n\u003ctd\u003eSupports the BR24BPG external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Load\u003c\/td\u003e\n\u003ctd\u003eSchneider publishes no runtime-versus-load figures for this model — contact SourceIT with your load in watts for a sizing calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Interface\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Alarms\u003c\/td\u003e\n\u003ctd\u003eAlarm when on battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eNot available on this model — there is no SmartSlot for an internal network management card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e301 mm (H) x 112 mm (W) x 380 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e12.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Mountable\u003c\/td\u003e\n\u003ctd\u003eNo — tower form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-15 to 45 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e45 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe BR1500GI presents 10 x C13 — 5 battery-backed, 5 surge-only, plus 2 jumper cords. All outlets are IEC 60320 C13, so a standard C13 kettle lead connects a PC, monitor, switch, router or NAS directly. Only the battery-backed outlets carry the load through an outage; the surge-only outlets stay dead when the mains fails, which is the point — put the printer and the monitor there and keep the battery for the machine that must not stop. The unit takes its own supply through an IEC 60320 C14 inlet on a normal 13 A Singapore wall socket — no dedicated circuit and no electrician needed.\u003c\/p\u003e\n\u003ch4\u003eSizing it: VA, watts and how much you can actually load\u003c\/h4\u003e\n\u003cp\u003eThe BR1500GI is rated 1500 VA apparent power and 865 W real power. Size against the \u003cstrong\u003ewatts\u003c\/strong\u003e, not the VA — the watt figure is the one that runs out first on modern IT loads. As a working rule, keep the connected load under about 70% of 865 W so you have headroom for inrush and for the battery ageing. Schneider publishes no runtime table for this model, so any minutes figure you see quoted elsewhere is someone's estimate, not a manufacturer specification. Send us your equipment list and we will work out the real number.\u003c\/p\u003e\n\u003ch4\u003eBattery and replacement cartridge\u003c\/h4\u003e\n\u003cp\u003eThe battery is a sealed maintenance-free lead-acid (VRLA) cartridge, 24 V 9.0 Ah. Typical recharge time is 8 h. The APC replacement cartridge for this model is \u003cstrong\u003eAPCRBC124\u003c\/strong\u003e — \u003ca href=\"\/products\/apc-replacement-battery-cartridge-124-apcrbc124\"\u003eAPCRBC124\u003c\/a\u003e is stocked by SourceIT. The cartridge is user-replaceable from the front of the unit; APC does not describe this model's battery as swappable while running, so plan a short shutdown for the change.\u003c\/p\u003e\n\u003ch4\u003eRack space and management software\u003c\/h4\u003e\n\u003cp\u003eThis is a tower unit and is not rack mountable, so it consumes no rack U and needs no rail kit. This model has no SmartSlot, so an AP9640 or AP9641 Network Management Card cannot be fitted — if you need SNMP monitoring or an Ethernet-managed UPS, step up to the APC Smart-UPS range and we will quote it. Bundled shutdown software is not documented for this model in the Schneider material we can verify, so we do not claim it; ask us and we will confirm what ships in the current carton.\u003c\/p\u003e\n\u003ch4\u003eExtended runtime\u003c\/h4\u003e\n\u003cp\u003eUniquely in this range, the BR1500GI accepts the \u003ca href=\"\/products\/apc-back-ups-pro-external-battery-pack-for-1500va-back-ups-pro-models-br24bpg\"\u003eBR24BPG external battery pack\u003c\/a\u003e — a 24 V, 372 VAh pack that multiplies the runtime available to the battery-backed outlets. None of the other Back-UPS Pro BR models on this site accept an external pack.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Back-UPS Pro BR Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cp\u003eSchneider does not itemise the carton contents for this model in the documentation we can verify, so we will not invent a list. What we can tell you is that the unit ships as a complete tower UPS with its battery installed. If the exact carton contents matter for your tender or your install, ask us before you order and we will open a unit and tell you what is actually in it.\u003c\/p\u003e\n\u003ch4\u003eAPC Back-UPS and Back-UPS Pro BR range at SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-500va-300w-tower-230v-br500ci-as\"\u003eBR500CI-AS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS, 500VA \/ 300W tower, 3x C13 — 500 VA \/ 300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-650va\"\u003eBR650MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 650VA \/ 390W tower, 6x C13 — 650 VA \/ 390 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-900va\"\u003eBR900MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 900VA \/ 540W tower, 6x C13 — 900 VA \/ 540 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1200VA \/ 720W tower, 8x C13, sine wave, USB A+C — 1200 VA \/ 720 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-1300va\"\u003eBR1300MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1300VA \/ 780W tower, 8x C13 — 1300 VA \/ 780 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBR1500GI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBack-UPS Pro, 1500VA \/ 865W tower, 10x C13, external pack capable — 1500 VA \/ 865 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1600va-960w-tower-230v-br1600mi\"\u003eBR1600MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13 — 1600 VA \/ 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13, sine wave, USB A+C — 1600 VA \/ 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-external-battery-pack-for-1500va-back-ups-pro-models-br24bpg\"\u003eBR24BPG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro external battery pack, 24 V \/ 372 VAh (for BR1500GI) — Battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMatching replacement battery cartridge\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003eAPCRBC124\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for the BR1500GI — \u003ca href=\"\/products\/apc-replacement-battery-cartridge-124-apcrbc124\"\u003eAPCRBC124\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch4\u003eExternal battery pack\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003eBR24BPG\u003c\/td\u003e\n\u003ctd\u003e24 V \/ 372 VAh external battery pack for the BR1500GI — \u003ca href=\"\/products\/apc-back-ups-pro-external-battery-pack-for-1500va-back-ups-pro-models-br24bpg\"\u003eview the BR24BPG\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003cp\u003eRail kits and network management cards do not apply to this range: every Back-UPS Pro BR model is a tower with no SmartSlot. For rack-mount or network-managed power protection, ask us about the APC Smart-UPS SMT, SMC and SMX ranges.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eLinks open on Schneider Electric's own site. Each one was checked before publication.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/BR1500GI\/apc-powersaving-backups-pro-1500-1500va-230v-lcd-10-iec-outlets-5-surge\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for the APC BR1500GI\u003c\/a\u003e — official product name, characteristics and the full document list (United Kingdom site)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eSchneider's direct datasheet PDF links sit behind a path that blocks automated retrieval, so we link the product page instead — every link above resolves and carries the current document. If you need the datasheet or manual emailed to you as a file for a tender submission, ask us and we will send it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC BR1500GI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 1500 VA and the 865 W rating?\u003c\/h4\u003e\n\u003cp\u003e1500 VA is apparent power and 865 W is real power. Your equipment consumes real power, so the 865 W figure is the one that limits what you can connect. Add up the wattage on the nameplates of everything you intend to back up and keep the total comfortably below 865 W.\u003c\/p\u003e\n\u003ch4\u003eHow long will the BR1500GI run my equipment?\u003c\/h4\u003e\n\u003cp\u003eIt depends entirely on load, and Schneider publishes no runtime table for this model — which is why you will not find minutes quoted on this page. A lightly loaded unit runs for many minutes; one near 865 W runs for a few. Send SourceIT your load in watts and we will calculate it against the 216 VAh (187 VAh usable runtime rating) battery rating rather than guess.\u003c\/p\u003e\n\u003ch4\u003eWhat does the \"GI\" in BR1500GI mean?\u003c\/h4\u003e\n\u003cp\u003eIt identifies the build variant. GI is the 230 V IEC-outlet Power-Saving Back-UPS Pro build, the only one in this family that accepts an external battery pack. These suffixes are not interchangeable — outlet counts, waveform and battery cartridge all change with them, so order by the exact part number.\u003c\/p\u003e\n\u003ch4\u003eIs the output a pure sine wave, and will it drive an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eNo. The BR1500GI produces a stepped approximation to a sinewave, as stated in its data sheet. That is fine for most desktops, routers, switches, NVRs and POS gear, but some active-PFC ATX power supplies will alarm or drop out on it. If your load has an active-PFC supply, choose the \u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e or \u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e instead — both are sine wave.\u003c\/p\u003e\n\u003ch4\u003eWhich replacement battery does it take, and can I fit it myself?\u003c\/h4\u003e\n\u003cp\u003eThe APC replacement battery cartridge for the BR1500GI is \u003cstrong\u003eAPCRBC124\u003c\/strong\u003e, stocked here: \u003ca href=\"\/products\/apc-replacement-battery-cartridge-124-apcrbc124\"\u003eAPCRBC124\u003c\/a\u003e. It is user-replaceable — no tools beyond a screwdriver and no service call. APC does not describe this model's battery as swappable while running, so shut the unit down for the swap. Expect three to five years of service in an air-conditioned office, and less in a hot, humid comms cupboard.\u003c\/p\u003e\n\u003ch4\u003eCan I rack mount it or add a network management card?\u003c\/h4\u003e\n\u003cp\u003eNo on both counts. The BR1500GI is a tower unit with no rack ears or rail kit option, and the Back-UPS Pro BR range has no SmartSlot, so an AP9640 or AP9641 card cannot be fitted. If you need a 19-inch rack UPS or SNMP monitoring, ask SourceIT about the APC Smart-UPS SMT, SMC and SMX ranges.\u003c\/p\u003e\n\u003ch4\u003eHow does the BR1500GI compare with the BR1600MI?\u003c\/h4\u003e\n\u003cp\u003eThe \u003ca href=\"\/products\/apc-back-ups-pro-1600va-960w-tower-230v-br1600mi\"\u003eBR1600MI\u003c\/a\u003e offers slightly more capacity at 1600 VA \/ 960 W, but the BR1500GI is the only model in this range that takes an external battery pack. Both are stocked by SourceIT in Singapore — tell us the load and the budget and we will tell you which one is the right buy.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC BR1500GI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the BR1500GI with a 2-year manufacturer warranty. Note that Schneider states three years inside the European Community and two years elsewhere — Singapore takes the two-year term, and any listing quoting three years for this market has copied the European figure.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/dZ-hRA5gJ48\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039177441444,"sku":"BR1500GI","price":835.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_24b836c0-7fc7-4bdd-93b4-c9dc72b36bbe.jpg?v=1789720183"},{"product_id":"apc-back-ups-pro-external-battery-pack-for-1500va-back-ups-pro-models-br24bpg","title":"APC External Battery Pack for 1500VA UPS","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC External Battery Pack for 1500VA UPS (BR24BPG) - Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eAPC BR24BPG External Battery Pack — More Runtime for a 1500VA Back-UPS Pro\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC BR24BPG is a 24 V DC, 372 VAh external battery pack that extends how long a compatible 1500 VA Back-UPS Pro can carry your load through an outage. In Singapore that usually means one of two things: riding out a longer PUB interruption instead of just a storm-time dip, or buying enough time for a clean, unattended shutdown of a workstation or small server when nobody is in the office.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat It Fits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAPC specifies the BR24BPG for 1500 VA Back-UPS Pro models. In the SourceIT catalogue that is the \u003ca href=\"\/products\/apc-back-ups-pro-1500va-865w-tower-230v-10x-iec-c13-outlets-avr-lcd-br1500gi\"\u003eAPC Back-UPS Pro BR1500GI\u003c\/a\u003e, whose own data sheet names the BR24BP \/ BR24BPG as its extended-runtime option. It is \u003cstrong\u003enot\u003c\/strong\u003e compatible with the BR650MI, BR900MI, BR1300MI, BR1600MI, BR1200SI, BR1600SI or BR500CI-AS — none of those models has an external battery connector. Check the part number on your UPS before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSealed Lead-Acid, Stackable, No Rack Space\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe pack holds sealed lead-acid batteries in a matching tower enclosure at 301 mm (H) x 112 mm (W) x 382 mm (D) and 13.4 kg, designed to sit alongside the UPS rather than in a rack. APC quotes 4 to 6 years for the cells. In a warm, humid comms cupboard expect the lower end of that range — heat, not cycles, is what kills VRLA batteries in this climate.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLocal Supply, GST Invoice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the BR24BPG as local Singapore stock with a GST invoice and local warranty support. Batteries are a consumable, so if you are buying a pack to refresh an ageing installation, ask us about the matching replacement cartridge for the UPS itself at the same time — replacing one and not the other leaves you with a mismatched bank.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC BR24BPG Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eEvery figure below is taken from the Schneider Electric BR24BPG product page and the APC BR24BPG product data sheet. Values Schneider does not publish for this part number are left out rather than estimated.\u003c\/p\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eBR24BPG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro External Battery Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExternal battery pack for APC Back-UPS Pro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower, stackable — not rack mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible UPS\u003c\/td\u003e\n\u003ctd\u003e1500 VA APC Back-UPS Pro models (BR1500GI in the SourceIT range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003e3 years repair or replace (stated in the APC product data sheet; this figure appears in a single official source, so confirm the term at order)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupported locally by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBattery Specifications\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed lead-acid (VRLA), mercury-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e18 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Rating\u003c\/td\u003e\n\u003ctd\u003e372 VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Service Life\u003c\/td\u003e\n\u003ctd\u003e4 to 6 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Replaceable\u003c\/td\u003e\n\u003ctd\u003eYes — the pack contains replaceable battery modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime Added\u003c\/td\u003e\n\u003ctd\u003eDepends on the connected load; Schneider publishes no runtime table for this pack — contact SourceIT with your load in watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e301 mm (H) x 112 mm (W) x 382 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e13.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003e2 battery modules, 1 connection cable and the user manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eTUV; RoHS compliant; mercury-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Mountable\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhich UPS models the BR24BPG fits\u003c\/h4\u003e\n\u003cp\u003eAPC lists the BR24BPG for 1500 VA Back-UPS Pro units. The model SourceIT stocks that accepts it is the \u003ca href=\"\/products\/apc-back-ups-pro-1500va-865w-tower-230v-10x-iec-c13-outlets-avr-lcd-br1500gi\"\u003eBR1500GI\u003c\/a\u003e (1500 VA \/ 865 W, 10 x IEC C13). The BR1500GI data sheet names the BR24BP and BR24BPG as its external battery pack options, which is the confirmation that matters.\u003c\/p\u003e\n\u003cp\u003eIt does \u003cstrong\u003enot\u003c\/strong\u003e fit the rest of the Back-UPS Pro BR range sold here — \u003ca href=\"\/products\/apc-back-ups-pro-br-650va\"\u003eBR650MI\u003c\/a\u003e, \u003ca href=\"\/products\/apc-back-ups-pro-br-900va\"\u003eBR900MI\u003c\/a\u003e, \u003ca href=\"\/products\/apc-back-ups-pro-br-1300va\"\u003eBR1300MI\u003c\/a\u003e, \u003ca href=\"\/products\/apc-back-ups-pro-1600va-960w-tower-230v-br1600mi\"\u003eBR1600MI\u003c\/a\u003e, \u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e, \u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e and \u003ca href=\"\/products\/apc-back-ups-500va-300w-tower-230v-br500ci-as\"\u003eBR500CI-AS\u003c\/a\u003e have no external battery connector. If you need longer runtime on one of those, the answer is a larger UPS, not a pack.\u003c\/p\u003e\n\u003ch4\u003eHow much extra runtime\u003c\/h4\u003e\n\u003cp\u003eThe pack is rated 372 VAh at 24 V DC. How many extra minutes that buys depends entirely on the load: at a light load it can more than double the runtime of the internal battery, and at a heavy load the gain is proportionally smaller. Schneider publishes no runtime-versus-load table for this pack, so we do not print one. Tell SourceIT your load in watts and we will calculate it.\u003c\/p\u003e\n\u003ch4\u003eInstallation and rack space\u003c\/h4\u003e\n\u003cp\u003eThe pack is a tower enclosure designed to stand beside or beneath the UPS — it takes no rack U and needs no rail kit. It connects to the UPS with the supplied cable. APC does not describe this pack as hot-connectable, so shut the UPS down before attaching it. Recharge time for the combined bank is longer than for the UPS alone; allow the unit to charge fully before you rely on the extra runtime.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Back-UPS Pro BR Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cp\u003e2 battery modules, 1 connection cable and the user manual.\u003c\/p\u003e\n\u003ch4\u003eThe UPS this pack is for\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBR1500GI\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro 1500VA \/ 865W, 10 x IEC C13, AVR, LCD — \u003ca href=\"\/products\/apc-back-ups-pro-1500va-865w-tower-230v-10x-iec-c13-outlets-avr-lcd-br1500gi\"\u003eview the BR1500GI\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPCRBC124\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for the BR1500GI — \u003ca href=\"\/products\/apc-replacement-battery-cartridge-124-apcrbc124\"\u003eview this cartridge\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eAPC Back-UPS and Back-UPS Pro BR range at SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-500va-300w-tower-230v-br500ci-as\"\u003eBR500CI-AS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS, 500VA \/ 300W tower, 3x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-650va\"\u003eBR650MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 650VA \/ 390W tower, 6x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-900va\"\u003eBR900MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 900VA \/ 540W tower, 6x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1200VA \/ 720W tower, 8x C13, sine wave, USB A+C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-1300va\"\u003eBR1300MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1300VA \/ 780W tower, 8x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1500va-865w-tower-230v-10x-iec-c13-outlets-avr-lcd-br1500gi\"\u003eBR1500GI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1500VA \/ 865W tower, 10x C13, external pack capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1600va-960w-tower-230v-br1600mi\"\u003eBR1600MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13, sine wave, USB A+C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBR24BPG (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBack-UPS Pro external battery pack, 24 V \/ 372 VAh (for BR1500GI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eRail kits and network management cards do not apply — this is a tower pack for a tower UPS, and the Back-UPS Pro BR range has no SmartSlot.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eLinks open on Schneider Electric's own site. Each one was checked before publication.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/www.se.com\/us\/en\/product\/BR24BPG\/apc-backups-pro-external-battery-pack\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for the APC BR24BPG\u003c\/a\u003e — official product name, characteristics and the full document list (United States site)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eSchneider's direct datasheet PDF link for this part sits behind a path that blocks automated retrieval, so we link the product page rather than publish a URL we cannot verify. Ask SourceIT if you need the datasheet emailed as a file for a tender submission.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC BR24BPG\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhich UPS models does the BR24BPG work with?\u003c\/h4\u003e\n\u003cp\u003e1500 VA APC Back-UPS Pro units. In the SourceIT range that is the \u003ca href=\"\/products\/apc-back-ups-pro-1500va-865w-tower-230v-10x-iec-c13-outlets-avr-lcd-br1500gi\"\u003eBR1500GI\u003c\/a\u003e. It does not fit the BR650MI, BR900MI, BR1300MI, BR1600MI, BR1200SI, BR1600SI or BR500CI-AS.\u003c\/p\u003e\n\u003ch4\u003eHow much runtime does it add?\u003c\/h4\u003e\n\u003cp\u003eThat depends on your load. The pack adds 372 VAh at 24 V DC on top of the UPS's internal battery. Schneider publishes no runtime table for it, so rather than quote a number that would not apply to your equipment, send us your load in watts and we will work it out.\u003c\/p\u003e\n\u003ch4\u003eWhat does the \"G\" in BR24BPG mean?\u003c\/h4\u003e\n\u003cp\u003eIt denotes the pack generation. APC has shipped BR24BP and BR24BPG variants of the 24 V Back-UPS Pro pack; the BR1500GI data sheet names both as valid options for that UPS. Order by the exact part number on your quotation.\u003c\/p\u003e\n\u003ch4\u003eCan I fit the batteries myself?\u003c\/h4\u003e\n\u003cp\u003eYes — the pack contains user-replaceable battery modules. APC does not describe the pack as hot-connectable, so power the UPS down before connecting or servicing it.\u003c\/p\u003e\n\u003ch4\u003eDoes it take rack space?\u003c\/h4\u003e\n\u003cp\u003eNo. It is a tower enclosure that stands beside or beneath the UPS. There is no rack-mount option and no rail kit for it.\u003c\/p\u003e\n\u003ch4\u003eHow long do the batteries last?\u003c\/h4\u003e\n\u003cp\u003eAPC quotes four to six years of typical service life. Singapore's heat and humidity push that toward the lower end, particularly in an unconditioned comms cupboard. Budget for replacement inside that window rather than at the end of it.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC BR24BPG sold by SourceIT comes with local Singapore warranty and a GST invoice. APC's own data sheet for this pack states a three-year repair-or-replace manufacturer warranty; that figure appears in a single official source, so we state it here rather than in the product heading and we will confirm the current term with the distributor on request.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039202181284,"sku":"BR24BPG","price":345.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_b128515a-c074-4b58-adf6-4e0a370b6b1d.png?v=1789720315"},{"product_id":"apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets","title":"APC Back-UPS Pro 1600VA, 8xC13, AVR, LCD, USB A+C","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Back-UPS Pro 1600VA, 8xC13, AVR, LCD, USB A+C (BR1600SI) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eAPC BR1600SI 1600 VA \/ 960 W UPS for Singapore's 230V \/ 50Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC BR1600SI is a 1600 VA \/ 960 W line-interactive UPS with sine wave output, built for 230 V, 50 Hz supplies — exactly what Singapore's PUB grid delivers. It rides through the short dips, brownouts and momentary interruptions that follow an afternoon thunderstorm, and its Automatic Voltage Regulation corrects high and low mains voltage \u003cem\u003ewithout\u003c\/em\u003e going to battery, so the cells are not cycled every time the supply wanders. Output is 8 x C13 — 6 battery-backed, 2 surge-only.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSine Wave Output for Active-PFC Power Supplies\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSchneider's official product name for the BR1600SI states sine wave output. That matters: modern active-PFC ATX power supplies, many NAS units and some network appliances can chatter, alarm or shut down on a stepped waveform. If you are protecting a workstation or small server built in the last few years, the sine wave build is the one to specify. Two USB charging ports — one Type A and one Type C — are built into the front for phones and accessories.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutlets, Runtime and Battery Life in a Humid Climate\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOutlets are 6 x IEC 60320 C13 (battery backup and surge protection) plus 2 x IEC 60320 C13 (surge protection only). The surge-only outlets are there for printers, monitors and chargers that do not need backup but do need protection — keeping them off the battery bank is what buys you runtime on the equipment that matters. The battery is a sealed maintenance-free lead-acid (VRLA) cartridge with a 3 to 5 year expected service life. Singapore's heat and humidity are hard on VRLA cells, so plan on a cartridge change inside that window rather than at the end of it; the replacement part is \u003ca href=\"\/products\/apc-replacement-battery-cartridge-163-apcrbc163\"\u003eAPCRBC163\u003c\/a\u003e. Schneider does not publish a runtime-versus-load table for the BR1600SI, so we do not print one — runtime depends entirely on how much of the 960 W you actually draw. Tell us your load in watts and we will size it for you.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSME Office, Home Office and Comms-Cabinet Duty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis is a tower unit at 260 mm (H) x 100 mm (W) x 368 mm (D), 12.1 kg (13.75 kg packaged) — it sits on a desk, under a counter or on the floor of a comms cupboard rather than in a rack, so it costs you no rack U. An RJ45 10\/100\/1000 Base-T port is built in to protect the data line as well as the power, which is worth having on a fibre-to-the-building service where the router is the thing that keeps dying. Everything SourceIT ships is local Singapore stock with a GST invoice and local warranty support — no grey imports, no chasing an overseas RMA.\u003c\/p\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC BR1600SI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eEvery figure below is taken from the Schneider Electric product page (United Kingdom) and the APC BR1600SI product data sheet as carried by two independent distributor mirrors that agree. Where Schneider does not publish a value for this exact part number, the row is left out rather than filled in from a similar model.\u003c\/p\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eBR1600SI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro, 1600VA\/960W, Tower, 230V, 8x IEC C13 outlets, Sine Wave, AVR, USB Type A + C ports, LCD, User Replaceable Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro BR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive with Automatic Voltage Regulation (AVR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e1600 VA \/ 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003eRepair or replace; Schneider states 2 years for the rest of the world and 3 years inside the European Community, so Singapore takes the 2-year term\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupported locally by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e960 W \/ 1600 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 1 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform (on battery)\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003e6 x IEC 60320 C13 (battery backup and surge protection) plus 2 x IEC 60320 C13 (surge protection only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e509 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Filtering\u003c\/td\u003e\n\u003ctd\u003eFull-time multi-pole noise filtering, 10% of IEEE surge let-through, instantaneous response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e176 to 294 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 3 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e10 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003eAutomatic Voltage Regulation (AVR) — corrects high and low mains voltage without switching to battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed maintenance-free lead-acid (VRLA), user replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e9.4 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Rating\u003c\/td\u003e\n\u003ctd\u003e260 VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e16 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC163\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Battery Life\u003c\/td\u003e\n\u003ctd\u003e3 to 5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Runtime\u003c\/td\u003e\n\u003ctd\u003eNo external battery pack is documented for this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Load\u003c\/td\u003e\n\u003ctd\u003eSchneider publishes no runtime-versus-load figures for this model — contact SourceIT with your load in watts for a sizing calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Interface\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Charging Ports\u003c\/td\u003e\n\u003ctd\u003e1 x USB Type A and 1 x USB Type C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Line Protection\u003c\/td\u003e\n\u003ctd\u003eRJ45 10\/100\/1000 Base-T Ethernet data line protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Alarms\u003c\/td\u003e\n\u003ctd\u003eAlarm when on battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eNot available on this model — there is no SmartSlot for an internal network management card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e260 mm (H) x 100 mm (W) x 368 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e12.1 kg (13.75 kg packaged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Mountable\u003c\/td\u003e\n\u003ctd\u003eNo — tower form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-15 to 45 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e45 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e0731304346920\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe BR1600SI presents 8 x C13 — 6 battery-backed, 2 surge-only. All outlets are IEC 60320 C13, so a standard C13 kettle lead connects a PC, monitor, switch, router or NAS directly. Only the battery-backed outlets carry the load through an outage; the surge-only outlets stay dead when the mains fails, which is the point — put the printer and the monitor there and keep the battery for the machine that must not stop. The unit takes its own supply through an IEC 60320 C14 inlet on a normal 13 A Singapore wall socket — no dedicated circuit and no electrician needed.\u003c\/p\u003e\n\u003ch4\u003eSizing it: VA, watts and how much you can actually load\u003c\/h4\u003e\n\u003cp\u003eThe BR1600SI is rated 1600 VA apparent power and 960 W real power. Size against the \u003cstrong\u003ewatts\u003c\/strong\u003e, not the VA — the watt figure is the one that runs out first on modern IT loads. As a working rule, keep the connected load under about 70% of 960 W so you have headroom for inrush and for the battery ageing. Schneider publishes no runtime table for this model, so any minutes figure you see quoted elsewhere is someone's estimate, not a manufacturer specification. Send us your equipment list and we will work out the real number.\u003c\/p\u003e\n\u003ch4\u003eBattery and replacement cartridge\u003c\/h4\u003e\n\u003cp\u003eThe battery is a sealed maintenance-free lead-acid (VRLA) cartridge, 24 V 9.4 Ah. Typical recharge time is 16 h. The APC replacement cartridge for this model is \u003cstrong\u003eAPCRBC163\u003c\/strong\u003e — \u003ca href=\"\/products\/apc-replacement-battery-cartridge-163-apcrbc163\"\u003eAPCRBC163\u003c\/a\u003e is stocked by SourceIT. The cartridge is user-replaceable from the front of the unit; APC does not describe this model's battery as swappable while running, so plan a short shutdown for the change.\u003c\/p\u003e\n\u003ch4\u003eRack space and management software\u003c\/h4\u003e\n\u003cp\u003eThis is a tower unit and is not rack mountable, so it consumes no rack U and needs no rail kit. This model has no SmartSlot, so an AP9640 or AP9641 Network Management Card cannot be fitted — if you need SNMP monitoring or an Ethernet-managed UPS, step up to the APC Smart-UPS range and we will quote it. Bundled shutdown software is not documented for this model in the Schneider material we can verify, so we do not claim it; ask us and we will confirm what ships in the current carton.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Back-UPS Pro BR Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cp\u003eSchneider does not itemise the carton contents for this model in the documentation we can verify, so we will not invent a list. What we can tell you is that the unit ships as a complete tower UPS with its battery installed. If the exact carton contents matter for your tender or your install, ask us before you order and we will open a unit and tell you what is actually in it.\u003c\/p\u003e\n\u003ch4\u003eAPC Back-UPS and Back-UPS Pro BR range at SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-500va-300w-tower-230v-br500ci-as\"\u003eBR500CI-AS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS, 500VA \/ 300W tower, 3x C13 — 500 VA \/ 300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-650va\"\u003eBR650MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 650VA \/ 390W tower, 6x C13 — 650 VA \/ 390 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-900va\"\u003eBR900MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 900VA \/ 540W tower, 6x C13 — 900 VA \/ 540 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1200VA \/ 720W tower, 8x C13, sine wave, USB A+C — 1200 VA \/ 720 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-1300va\"\u003eBR1300MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1300VA \/ 780W tower, 8x C13 — 1300 VA \/ 780 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1500va-865w-tower-230v-10x-iec-c13-outlets-avr-lcd-br1500gi\"\u003eBR1500GI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1500VA \/ 865W tower, 10x C13, external pack capable — 1500 VA \/ 865 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1600va-960w-tower-230v-br1600mi\"\u003eBR1600MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13 — 1600 VA \/ 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBR1600SI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13, sine wave, USB A+C — 1600 VA \/ 960 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-external-battery-pack-for-1500va-back-ups-pro-models-br24bpg\"\u003eBR24BPG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro external battery pack, 24 V \/ 372 VAh (for BR1500GI) — Battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMatching replacement battery cartridge\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003eAPCRBC163\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for the BR1600SI — \u003ca href=\"\/products\/apc-replacement-battery-cartridge-163-apcrbc163\"\u003eAPCRBC163\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003cp\u003eRail kits and network management cards do not apply to this range: every Back-UPS Pro BR model is a tower with no SmartSlot. For rack-mount or network-managed power protection, ask us about the APC Smart-UPS SMT, SMC and SMX ranges.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eLinks open on Schneider Electric's own site. Each one was checked before publication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/BR1600SI\/apc-backups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets-sine-wave-avr-usb-type-a-+-c-ports-lcd-user-replaceable-battery\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for the APC BR1600SI\u003c\/a\u003e — official product name, characteristics and the full document list (United Kingdom site)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/SPD_AHUG-B6CBPT_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Back-UPS Pro BR1200SI \/ BR1600SI User Manual (Schneider document library)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's direct datasheet PDF links sit behind a path that blocks automated retrieval, so we link the product page and the document library entry instead — every link above resolves and carries the current document. If you need the datasheet or manual emailed to you as a file for a tender submission, ask us and we will send it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC BR1600SI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 1600 VA and the 960 W rating?\u003c\/h4\u003e\n\u003cp\u003e1600 VA is apparent power and 960 W is real power. Your equipment consumes real power, so the 960 W figure is the one that limits what you can connect. Add up the wattage on the nameplates of everything you intend to back up and keep the total comfortably below 960 W.\u003c\/p\u003e\n\u003ch4\u003eHow long will the BR1600SI run my equipment?\u003c\/h4\u003e\n\u003cp\u003eIt depends entirely on load, and Schneider publishes no runtime table for this model — which is why you will not find minutes quoted on this page. A lightly loaded unit runs for many minutes; one near 960 W runs for a few. Send SourceIT your load in watts and we will calculate it against the 260 VAh battery rating rather than guess.\u003c\/p\u003e\n\u003ch4\u003eWhat does the \"SI\" in BR1600SI mean?\u003c\/h4\u003e\n\u003cp\u003eIt identifies the build variant. SI is the newer 230 V build with true sine wave output and two USB charging ports (Type A and Type C) — a genuinely different unit from the same-VA \"MI\" model, not just a cosmetic variation. These suffixes are not interchangeable — outlet counts, waveform and battery cartridge all change with them, so order by the exact part number.\u003c\/p\u003e\n\u003ch4\u003eIs the output a pure sine wave, and will it drive an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eYes — Schneider's official product name for the BR1600SI states sine wave output, so it suits active-PFC ATX power supplies, NAS units and other equipment that objects to a stepped waveform.\u003c\/p\u003e\n\u003ch4\u003eWhich replacement battery does it take, and can I fit it myself?\u003c\/h4\u003e\n\u003cp\u003eThe APC replacement battery cartridge for the BR1600SI is \u003cstrong\u003eAPCRBC163\u003c\/strong\u003e, stocked here: \u003ca href=\"\/products\/apc-replacement-battery-cartridge-163-apcrbc163\"\u003eAPCRBC163\u003c\/a\u003e. It is user-replaceable — no tools beyond a screwdriver and no service call. APC does not describe this model's battery as swappable while running, so shut the unit down for the swap. Expect three to five years of service in an air-conditioned office, and less in a hot, humid comms cupboard.\u003c\/p\u003e\n\u003ch4\u003eCan I rack mount it or add a network management card?\u003c\/h4\u003e\n\u003cp\u003eNo on both counts. The BR1600SI is a tower unit with no rack ears or rail kit option, and the Back-UPS Pro BR range has no SmartSlot, so an AP9640 or AP9641 card cannot be fitted. If you need a 19-inch rack UPS or SNMP monitoring, ask SourceIT about the APC Smart-UPS SMT, SMC and SMX ranges.\u003c\/p\u003e\n\u003ch4\u003eHow does the BR1600SI compare with the BR1600MI?\u003c\/h4\u003e\n\u003cp\u003eThe \u003ca href=\"\/products\/apc-back-ups-pro-1600va-960w-tower-230v-br1600mi\"\u003eBR1600MI\u003c\/a\u003e is the same 1600 VA \/ 960 W capacity in the older stepped-approximation build without USB charging ports — cheaper, but not for active-PFC loads. Both are stocked by SourceIT in Singapore — tell us the load and the budget and we will tell you which one is the right buy.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC BR1600SI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the BR1600SI with a 2-year manufacturer warranty. Note that Schneider states three years inside the European Community and two years elsewhere — Singapore takes the two-year term, and any listing quoting three years for this market has copied the European figure.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/dZ-hRA5gJ48\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039207882916,"sku":"BR1600SI","price":815.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-br1600si-image-apc-apc-brand-image-apc-apc-brand-image-apc-back-ups-pro-1600va960w-tower-230v-8x-iec-c13-outlets-sine-wave-avr-usb-type-a-c-ports-lcd-br1600-884486.jpg?v=1671696949"},{"product_id":"apc-easy-ups-on-line-srv-1000va-230v-srv1ki","title":"APC Easy UPS On-Line SRV 1000VA 230V","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRV 1000VA 230V (SRV1KI) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDouble-Conversion On-Line Protection for Singapore's 230 V \/ 50 Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC SRV1KI is a \u003cstrong\u003edouble-conversion on-line UPS\u003c\/strong\u003e: incoming mains is rectified to DC and rebuilt as a clean sine wave output, so the connected load never sees the supply it is actually plugged into. That matters on the Singapore grid, where the day-to-day problem is rarely a full blackout and much more often the voltage sag that arrives with an afternoon thunderstorm, or the disturbance from a large motor load elsewhere in the building. The unit rides those out on its inverter, holding a 160–280 V full-load input window before it needs the battery at all.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e1000 VA of Protected Capacity, 800 W of Real Power\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRated at \u003cstrong\u003e1000 VA \/ 800 W\u003c\/strong\u003e, the SRV1KI is sized for a small comms cabinet, a single server or a workgroup of network equipment. Size against the watts figure rather than the VA figure — servers, switches and storage are watts loads — and leave headroom rather than running it hard, which costs you both runtime and battery life. On-line efficiency is 88 % at full load, and output distortion is held to 3 %, which is what an active-PFC server power supply expects to see.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTower Format with Three C13 Outlets\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA tower at 223 mm (H) × 145 mm (W) × 288 mm (D) and 9.3 kg net \/ 10.6 kg shipping, the SRV1KI suits an SME office, a home office or a floor comms position where there is no rack to mount into. Output is 3 × IEC 60320 C13 (all battery backup and surge protected), and every one of them carries battery backup and surge protection — there is no surge-only bank to accidentally plug a server into. Input connection is IEC 60320 C14 inlet, 1.5 m input cord.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBatteries, Service Life and Singapore's Heat\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInternal batteries are maintenance-free sealed VRLA (24 V DC, from 2 × 12 V 9 Ah blocks), recharging in 4 hours, with an expected service life of 3–5 years. Heat is what actually kills UPS batteries, and a poorly ventilated cabinet in Singapore's climate will take years off them — the unit is rated for 0 °C to 40 °C and runs at 50 dBA, so give it airflow. When the time comes the cartridge is \u003cstrong\u003eAPCRBCV203 (VRLA, 9 Ah, 24 V DC)\u003c\/strong\u003e and it is user-replaceable, with battery condition readable from the front-panel LCD.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBuy the APC SRV1KI in Singapore with Local Warranty and GST Invoice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the APC SRV1KI from Singapore with a GST invoice and local warranty support, backed by APC's 2-year manufacturer warranty. Tell us the load you need to protect — in watts, and how long you need it to stay up — and we will size the unit, the cartridge and the network card properly rather than sell you the nearest number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRV1KI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRV1KI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSRV1KI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \/ Series\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric — Easy UPS On-Line SRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider product name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line, 1000VA\/800W, Tower, 230V, 3x IEC C13 outlets, Intelligent Card Slot, LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal, configurable for 220 \/ 230 \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz ± 3 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage distortion\u003c\/td\u003e\n\u003ctd\u003e3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3 : 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-line efficiency\u003c\/td\u003e\n\u003ctd\u003e88 % at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput connections\u003c\/td\u003e\n\u003ctd\u003e3 × IEC 60320 C13 (all battery backup and surge protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e600 Joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range\u003c\/td\u003e\n\u003ctd\u003e160–280 V at full load; 110–285 V at half load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet, 1.5 m input cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed valve-regulated lead-acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC, from 2 × 12 V 9 Ah blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement battery cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBCV203 (VRLA, 9 Ah, 24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical recharge time\u003c\/td\u003e\n\u003ctd\u003e4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected battery life\u003c\/td\u003e\n\u003ctd\u003e3–5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime\u003c\/td\u003e\n\u003ctd\u003eUp to 4 minutes at full load; approximately 10 minutes at half load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal battery pack\u003c\/td\u003e\n\u003ctd\u003eNot supported on this model — internal batteries only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eYes (USB cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial port\u003c\/td\u003e\n\u003ctd\u003eRS-232, DB-9 (configuration cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard slot\u003c\/td\u003e\n\u003ctd\u003e1 × Intelligent Card Slot (Schneider’s term — not a Smart-UPS “SmartSlot”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork management card\u003c\/td\u003e\n\u003ctd\u003eAPV9601 — APC Easy UPS On-Line SRV SNMP card (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutdown software\u003c\/td\u003e\n\u003ctd\u003eCompatible with PowerChute Serial Shutdown and PowerChute Business Edition — Schneider FAQ FA315835 lists SRV models of 3 kVA and below as supported over USB or serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eNot available on this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm\u003c\/td\u003e\n\u003ctd\u003eOn battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e223 mm (H) × 145 mm (W) × 288 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e9.3 kg net \/ 10.6 kg shipping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity\u003c\/td\u003e\n\u003ctd\u003e0–95 % relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating elevation\u003c\/td\u003e\n\u003ctd\u003e0–3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible noise\u003c\/td\u003e\n\u003ctd\u003e50 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications and standards\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, EAC, TISI; EN\/IEC 62040-1, EN\/IEC 62040-2; EU and China RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe SRV1KI provides \u003cstrong\u003e3 × IEC 60320 C13 (all battery backup and surge protected)\u003c\/strong\u003e. Every outlet is fed from the inverter, so all of them carry battery backup and surge protection — there is no surge-only bank on this model. Rated capacity is 1000 VA \/ 800 W: size the load against the \u003cstrong\u003e800 W figure\u003c\/strong\u003e, because a server, switch or storage array is a watts load, not a VA load.\u003c\/p\u003e\n\u003ch4\u003eInput and circuit requirements\u003c\/h4\u003e\n\u003cp\u003eInput connection is \u003cstrong\u003eIEC 60320 C14 inlet, 1.5 m input cord\u003c\/strong\u003e. Singapore mains is 230 V \/ 50 Hz, which sits comfortably inside this unit's 160–280 V full-load input window, and the on-line inverter regenerates the output waveform continuously rather than switching to battery for every dip — useful during the voltage sags that accompany a thunderstorm on the PUB grid.\u003c\/p\u003e\n\u003ch4\u003eFootprint\u003c\/h4\u003e\n\u003cp\u003eThis is a \u003cstrong\u003etower\u003c\/strong\u003e unit at 223 mm (H) × 145 mm (W) × 288 mm (D) and it is not rack-mountable. The rackmount equivalent at the same capacity is a separate part number — see the ordering block below.\u003c\/p\u003e\n\u003ch4\u003eBatteries and runtime\u003c\/h4\u003e\n\u003cp\u003eThe SRV1KI runs on sealed maintenance-free VRLA batteries at 24 V DC, from 2 × 12 V 9 Ah blocks, and recharges in 4 hours. Expected service life is 3–5 years in a temperature-controlled room; Singapore's ambient heat and humidity are the main things that shorten it, so a comms cabinet with airflow is worth the effort.\u003c\/p\u003e\n\u003cp\u003eSchneider's published runtime figure for this model is \u003cstrong\u003eup to 4 minutes at full load, and approximately 10 minutes at half load\u003c\/strong\u003e. Runtime always depends on the actual connected load — treat that as the manufacturer's headline figure, not a guarantee for your particular equipment.\u003c\/p\u003e\n\u003cp\u003eThe matching replacement battery cartridge is \u003cstrong\u003eAPCRBCV203 (VRLA, 9 Ah, 24 V DC)\u003c\/strong\u003e. Note this is the APCRBCV series used by Easy UPS On-Line, which is a different range from the APCRBC cartridges used by Smart-UPS — do not substitute across the two.\u003c\/p\u003e\n\u003cp\u003eThis model does \u003cstrong\u003enot\u003c\/strong\u003e accept an external battery pack. If you need longer autonomy at this capacity, the extended-runtime power-module models are the correct product — they are listed in the ordering block below.\u003c\/p\u003e\n\u003ch4\u003eManagement options\u003c\/h4\u003e\n\u003cp\u003eThe SRV1KI has a USB port, an RS-232 DB-9 serial port and one \u003cstrong\u003eIntelligent Card Slot\u003c\/strong\u003e. Schneider's card for that slot is the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e. The Easy UPS On-Line SRV range uses a different card family from Smart-UPS: the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will \u003cstrong\u003enot\u003c\/strong\u003e work in this UPS.\u003c\/p\u003e\n\u003cp\u003eFor direct USB or serial shutdown of a single host, Schneider's FAQ FA315835 lists SRV models of 3 kVA and below as supported by PowerChute Serial Shutdown and PowerChute Business Edition. PowerChute itself is a Schneider download rather than a licence sold with the UPS — ask us if you want the current version confirmed for your operating system before you commission.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 × IEC C13 to Schuko power cable\u003c\/li\u003e\n\u003cli\u003e1 × IEC C13 to C14 power cable\u003c\/li\u003e\n\u003cli\u003e1 × USB cable\u003c\/li\u003e\n\u003cli\u003e1 × RS-232 configuration cable\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's documented carton contents list an IEC C13-to-Schuko (European) cord. In Singapore these units are normally fed from a rack PDU or a locally fitted BS 1363 cord — tell us how you intend to power it and we will confirm what ships in the Singapore carton and supply the right cordage with the order.\u003c\/p\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — tower models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRV1KI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-srv2ki\"\u003eAPC Easy UPS On-Line SRV2KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-srv3ki\"\u003eAPC Easy UPS On-Line SRV3KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — rackmount 2U models (supplied with SRVRK1 rail kit)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri\"\u003eAPC Easy UPS On-Line SRV1KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri\"\u003eAPC Easy UPS On-Line SRV2KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri\"\u003eAPC Easy UPS On-Line SRV3KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eExtended-runtime models (no internal battery, external pack supplied)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery pack\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-external-battery-pack-srv3kri\"\u003eAPC Easy UPS On-Line SRVPM1KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · SRV36BP-9A (36 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-with-extended-runtime-battery-pack-srv2kil\"\u003eAPC Easy UPS On-Line SRVPM2KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-with-extended-runtime-battery-pack-srv3kil\"\u003eAPC Easy UPS On-Line SRVPM3KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eLarger Easy UPS On-Line SRV models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity and format\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-6000va-230v-srv6ki\"\u003eAPC Easy UPS On-Line SRV6KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-10000va-230v-srv10ki\"\u003eAPC Easy UPS On-Line SRV10KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-6000va-230v-with-railkit-external-battery-pack-srv6krirk\"\u003eAPC Easy UPS On-Line SRV6KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-railkit-external-battery-pack-srv10krirk\"\u003eAPC Easy UPS On-Line SRV10KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eAccessories for this UPS\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWhat it is\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPC Easy UPS On-Line SRV SNMP Card (APV9601)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSNMP network management card for the Intelligent Card Slot. The correct card for Easy UPS On-Line SRV — the Smart-UPS AP9640 and AP9641 cards do not fit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPCRBCV203 (VRLA, 9 Ah, 24 V DC)\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for this model. User-replaceable. Order by this exact part number — the APCRBCV series is specific to Easy UPS On-Line and is not interchangeable with Smart-UPS APCRBC cartridges. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e to order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/SRV1KI\/apc-easy-ups-on-line-srv-1000va-230v\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Schneider Electric product page for the APC SRV1KI\u003c\/a\u003e — Singapore regional page. Schneider publishes the product datasheet, user guide and environmental disclosure from the document list on that page.\u003c\/p\u003e\n\u003cp\u003eSchneider serves its APC datasheet PDFs from a redirecting download host that regularly returns the wrong model's document, so we do not publish direct PDF links that we cannot verify resolve to the right part number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with the model you need and we will send the correct current-revision datasheet and user manual, along with a GST-invoiced quotation.\u003c\/p\u003e\n\u003cp\u003eEvery specification on this page was taken from Schneider Electric's own product page and its published product datasheet or user manual for this exact part number. Where Schneider's own sources disagreed, or published nothing, the field has been left out rather than estimated.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRV1KI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 1000 VA and 800 W ratings, and how do I size it?\u003c\/h4\u003e\n\u003cp\u003eVA is apparent power, watts is real power. The SRV1KI is rated 1000 VA \/ 800 W, an output power factor of 0.8. Add up the watts of everything you intend to protect, keep the total under 800 W, and leave headroom — loading a UPS to 100 % shortens both runtime and battery life. As a rough Singapore rule of thumb, a 1U rack server draws 200–400 W, a 24-port PoE switch 150–400 W depending on how much PoE is actually drawn, and a small NAS 60–120 W. Send us the list and we will size it.\u003c\/p\u003e\n\u003ch4\u003eHow long will the SRV1KI run my equipment?\u003c\/h4\u003e\n\u003cp\u003eSchneider's published figure for this model is \u003cstrong\u003eup to 4 minutes at full load, and approximately 10 minutes at half load\u003c\/strong\u003e, with healthy batteries.\u003c\/p\u003e\n\u003cp\u003eWhat matters in practice is that an on-line UPS in this class is sized for a clean shutdown or a generator start, not for riding through a long outage. If you need tens of minutes, the extended-runtime power-module models with external battery packs are the right product. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with your load in watts and the autonomy you want.\u003c\/p\u003e\n\u003ch4\u003eIs the output a true sine wave, and will it work with an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eYes. Schneider's datasheet for this exact model states a \u003cstrong\u003esine wave\u003c\/strong\u003e output with 3 % voltage distortion, and the topology is \u003cstrong\u003edouble conversion on-line\u003c\/strong\u003e — the load is fed from the inverter continuously rather than being switched over when mains fails. That is what an active-PFC server or workstation PSU wants; the step-approximated output of a low-cost standby UPS is what causes those supplies to trip. Schneider does not publish a numeric transfer time for this model and we do not claim one.\u003c\/p\u003e\n\u003ch4\u003eWhat do the different Easy UPS On-Line suffixes mean?\u003c\/h4\u003e\n\u003cp\u003eThey are genuinely different builds, not marketing variants. \u003cstrong\u003eKI\u003c\/strong\u003e is a tower with internal batteries. \u003cstrong\u003eKRI\u003c\/strong\u003e is the 2U rackmount build of the same capacity — different outlet count and dimensions, so do not read tower specs onto a rack unit. \u003cstrong\u003ePM…IL\u003c\/strong\u003e is an extended-runtime power module with no internal batteries, supplied with an external pack. \u003cstrong\u003e-E\u003c\/strong\u003e is the newer generation with a 0.9 output power factor, so an SRV3KI-E delivers 2700 W where this generation delivers 2400 W at the same 3 kVA. \u003cstrong\u003eRK\u003c\/strong\u003e means the rail kit is included in the part number.\u003c\/p\u003e\n\u003ch4\u003eWhich replacement battery cartridge does the SRV1KI take, and can I change it myself?\u003c\/h4\u003e\n\u003cp\u003eThe cartridge is \u003cstrong\u003eAPCRBCV203 (VRLA, 9 Ah, 24 V DC)\u003c\/strong\u003e. It is user-replaceable, and the batteries are the consumable part of any UPS — expect 3–5 years in a well-ventilated room, less in a hot cabinet, which is the usual Singapore constraint. Order by that exact part number: the \u003cstrong\u003eAPCRBCV\u003c\/strong\u003e series belongs to Easy UPS On-Line and is \u003cem\u003enot\u003c\/em\u003e interchangeable with the \u003cstrong\u003eAPCRBC\u003c\/strong\u003e cartridges used by Smart-UPS, even where the voltage looks similar. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e to order one.\u003c\/p\u003e\n\u003ch4\u003eCan the SRV1KI be rack mounted?\u003c\/h4\u003e\n\u003cp\u003eNo. This is a tower unit at 223 mm (H) × 145 mm (W) × 288 mm (D). Schneider builds the rackmount version as a separate part number — the 2U SRVxKRI family listed in the ordering block above. The two are not convertible, and their outlet counts and dimensions differ, so pick the form factor at the point of order.\u003c\/p\u003e\n\u003ch4\u003eHow do I monitor it over the network?\u003c\/h4\u003e\n\u003cp\u003eFit the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e in the UPS Intelligent Card Slot. That is the Easy UPS On-Line card — the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will not work here. Without a card you still get USB and RS-232 for a direct shutdown link to one host, with PowerChute Serial Shutdown or PowerChute Business Edition. Note that Schneider has discontinued the APV9601; ask us about current stock and the AP9544 successor before you commit to a monitoring design.\u003c\/p\u003e\n\u003ch4\u003eIs the SRV1KI covered by warranty in Singapore?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC SRV1KI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRV1KI with a 2-year manufacturer warranty. Schneider publishes a single worldwide figure of “2 years repair or replace” for the Easy UPS On-Line SRV range — there is no separate European and rest-of-world split on this family, so the term above is the one that applies in Singapore.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bzQk-YuLvCM\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039210930340,"sku":"SRV1KI","price":500.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-easy-ups-on-line-srv-1000va-230v-srv1ki-377202.jpg?v=1671696949"},{"product_id":"apc-easy-ups-on-line-srv-2000va-230v-srv2ki","title":"APC Easy UPS On-Line SRV 2000VA 230V","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRV 2000VA 230V (SRV2KI) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDouble-Conversion On-Line Protection for Singapore's 230 V \/ 50 Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC SRV2KI is a \u003cstrong\u003edouble-conversion on-line UPS\u003c\/strong\u003e: incoming mains is rectified to DC and rebuilt as a clean sine wave output, so the connected load never sees the supply it is actually plugged into. That matters on the Singapore grid, where the day-to-day problem is rarely a full blackout and much more often the voltage sag that arrives with an afternoon thunderstorm, or the disturbance from a large motor load elsewhere in the building. The unit rides those out on its inverter, holding a 160–280 V full-load input window before it needs the battery at all.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e2000 VA of Protected Capacity, 1600 W of Real Power\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRated at \u003cstrong\u003e2000 VA \/ 1600 W\u003c\/strong\u003e, the SRV2KI is sized for a comms cabinet, a pair of servers or a PoE switch stack. Size against the watts figure rather than the VA figure — servers, switches and storage are watts loads — and leave headroom rather than running it hard, which costs you both runtime and battery life. On-line efficiency is 88 % at full load, and output distortion is held to 3 %, which is what an active-PFC server power supply expects to see.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTower Format with Four C13 Outlets\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA tower at 238 mm (H) × 145 mm (W) × 400 mm (D) and 16.8 kg net \/ 18.1 kg shipping, the SRV2KI suits an SME office, a home office or a floor comms position where there is no rack to mount into. Output is 4 × IEC 60320 C13 (all battery backup and surge protected), and every one of them carries battery backup and surge protection — there is no surge-only bank to accidentally plug a server into. Input connection is IEC 60320 C14 inlet, 1.5 m input cord.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBatteries, Service Life and Singapore's Heat\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInternal batteries are maintenance-free sealed VRLA (48 V DC, from 4 × 12 V 9 Ah blocks), recharging in 4 hours, with an expected service life of 3–5 years. Heat is what actually kills UPS batteries, and a poorly ventilated cabinet in Singapore's climate will take years off them — the unit is rated for 0 °C to 40 °C and runs at 50 dBA, so give it airflow. When the time comes the cartridge is \u003cstrong\u003eAPCRBCV204 (VRLA, 9 Ah, 48 V DC)\u003c\/strong\u003e and it is user-replaceable, with battery condition readable from the front-panel LCD.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBuy the APC SRV2KI in Singapore with Local Warranty and GST Invoice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the APC SRV2KI from Singapore with a GST invoice and local warranty support, backed by APC's 2-year manufacturer warranty. Tell us the load you need to protect — in watts, and how long you need it to stay up — and we will size the unit, the cartridge and the network card properly rather than sell you the nearest number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRV2KI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRV2KI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSRV2KI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \/ Series\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric — Easy UPS On-Line SRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider product name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line, 2000VA\/1600W, Tower, 230V, 4x IEC C13 outlets, Intelligent Card Slot, LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal, configurable for 220 \/ 230 \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz ± 3 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage distortion\u003c\/td\u003e\n\u003ctd\u003e3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3 : 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-line efficiency\u003c\/td\u003e\n\u003ctd\u003e88 % at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput connections\u003c\/td\u003e\n\u003ctd\u003e4 × IEC 60320 C13 (all battery backup and surge protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e600 Joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal bypass\u003c\/td\u003e\n\u003ctd\u003eAutomatic and manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range\u003c\/td\u003e\n\u003ctd\u003e160–280 V at full load; 110–285 V at half load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet, 1.5 m input cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed valve-regulated lead-acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e48 V DC, from 4 × 12 V 9 Ah blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement battery cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBCV204 (VRLA, 9 Ah, 48 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical recharge time\u003c\/td\u003e\n\u003ctd\u003e4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected battery life\u003c\/td\u003e\n\u003ctd\u003e3–5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime\u003c\/td\u003e\n\u003ctd\u003eUp to 4 minutes at full load; approximately 10 minutes at half load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal battery pack\u003c\/td\u003e\n\u003ctd\u003eNot supported on this model — internal batteries only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eYes (USB cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial port\u003c\/td\u003e\n\u003ctd\u003eRS-232, DB-9 (configuration cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard slot\u003c\/td\u003e\n\u003ctd\u003e1 × Intelligent Card Slot (Schneider’s term — not a Smart-UPS “SmartSlot”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork management card\u003c\/td\u003e\n\u003ctd\u003eAPV9601 — APC Easy UPS On-Line SRV SNMP card (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutdown software\u003c\/td\u003e\n\u003ctd\u003eCompatible with PowerChute Serial Shutdown and PowerChute Business Edition — Schneider FAQ FA315835 lists SRV models of 3 kVA and below as supported over USB or serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eNot available on this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm\u003c\/td\u003e\n\u003ctd\u003eOn battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e238 mm (H) × 145 mm (W) × 400 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e16.8 kg net \/ 18.1 kg shipping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity\u003c\/td\u003e\n\u003ctd\u003e0–95 % relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating elevation\u003c\/td\u003e\n\u003ctd\u003e0–3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible noise\u003c\/td\u003e\n\u003ctd\u003e50 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal dissipation\u003c\/td\u003e\n\u003ctd\u003e745 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack (RAL 7010)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications and standards\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, EAC, TISI; EN\/IEC 62040-1, EN\/IEC 62040-2; EU and China RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe SRV2KI provides \u003cstrong\u003e4 × IEC 60320 C13 (all battery backup and surge protected)\u003c\/strong\u003e. Every outlet is fed from the inverter, so all of them carry battery backup and surge protection — there is no surge-only bank on this model. Rated capacity is 2000 VA \/ 1600 W: size the load against the \u003cstrong\u003e1600 W figure\u003c\/strong\u003e, because a server, switch or storage array is a watts load, not a VA load.\u003c\/p\u003e\n\u003ch4\u003eInput and circuit requirements\u003c\/h4\u003e\n\u003cp\u003eInput connection is \u003cstrong\u003eIEC 60320 C14 inlet, 1.5 m input cord\u003c\/strong\u003e. Singapore mains is 230 V \/ 50 Hz, which sits comfortably inside this unit's 160–280 V full-load input window, and the on-line inverter regenerates the output waveform continuously rather than switching to battery for every dip — useful during the voltage sags that accompany a thunderstorm on the PUB grid.\u003c\/p\u003e\n\u003ch4\u003eFootprint\u003c\/h4\u003e\n\u003cp\u003eThis is a \u003cstrong\u003etower\u003c\/strong\u003e unit at 238 mm (H) × 145 mm (W) × 400 mm (D) and it is not rack-mountable. The rackmount equivalent at the same capacity is a separate part number — see the ordering block below.\u003c\/p\u003e\n\u003ch4\u003eBatteries and runtime\u003c\/h4\u003e\n\u003cp\u003eThe SRV2KI runs on sealed maintenance-free VRLA batteries at 48 V DC, from 4 × 12 V 9 Ah blocks, and recharges in 4 hours. Expected service life is 3–5 years in a temperature-controlled room; Singapore's ambient heat and humidity are the main things that shorten it, so a comms cabinet with airflow is worth the effort.\u003c\/p\u003e\n\u003cp\u003eSchneider's published runtime figure for this model is \u003cstrong\u003eup to 4 minutes at full load, and approximately 10 minutes at half load\u003c\/strong\u003e. Runtime always depends on the actual connected load — treat that as the manufacturer's headline figure, not a guarantee for your particular equipment.\u003c\/p\u003e\n\u003cp\u003eThe matching replacement battery cartridge is \u003cstrong\u003eAPCRBCV204 (VRLA, 9 Ah, 48 V DC)\u003c\/strong\u003e. Note this is the APCRBCV series used by Easy UPS On-Line, which is a different range from the APCRBC cartridges used by Smart-UPS — do not substitute across the two.\u003c\/p\u003e\n\u003cp\u003eThis model does \u003cstrong\u003enot\u003c\/strong\u003e accept an external battery pack. If you need longer autonomy at this capacity, the extended-runtime power-module models are the correct product — they are listed in the ordering block below.\u003c\/p\u003e\n\u003ch4\u003eManagement options\u003c\/h4\u003e\n\u003cp\u003eThe SRV2KI has a USB port, an RS-232 DB-9 serial port and one \u003cstrong\u003eIntelligent Card Slot\u003c\/strong\u003e. Schneider's card for that slot is the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e. The Easy UPS On-Line SRV range uses a different card family from Smart-UPS: the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will \u003cstrong\u003enot\u003c\/strong\u003e work in this UPS.\u003c\/p\u003e\n\u003cp\u003eFor direct USB or serial shutdown of a single host, Schneider's FAQ FA315835 lists SRV models of 3 kVA and below as supported by PowerChute Serial Shutdown and PowerChute Business Edition. PowerChute itself is a Schneider download rather than a licence sold with the UPS — ask us if you want the current version confirmed for your operating system before you commission.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 × IEC C13 to Schuko power cable\u003c\/li\u003e\n\u003cli\u003e1 × IEC C13 to C14 power cable\u003c\/li\u003e\n\u003cli\u003e1 × USB cable\u003c\/li\u003e\n\u003cli\u003e1 × RS-232 configuration cable\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's documented carton contents list an IEC C13-to-Schuko (European) cord. In Singapore these units are normally fed from a rack PDU or a locally fitted BS 1363 cord — tell us how you intend to power it and we will confirm what ships in the Singapore carton and supply the right cordage with the order.\u003c\/p\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — tower models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-230v-srv1ki\"\u003eAPC Easy UPS On-Line SRV1KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRV2KI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-srv3ki\"\u003eAPC Easy UPS On-Line SRV3KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — rackmount 2U models (supplied with SRVRK1 rail kit)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri\"\u003eAPC Easy UPS On-Line SRV1KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri\"\u003eAPC Easy UPS On-Line SRV2KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri\"\u003eAPC Easy UPS On-Line SRV3KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eExtended-runtime models (no internal battery, external pack supplied)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery pack\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-external-battery-pack-srv3kri\"\u003eAPC Easy UPS On-Line SRVPM1KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · SRV36BP-9A (36 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-with-extended-runtime-battery-pack-srv2kil\"\u003eAPC Easy UPS On-Line SRVPM2KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-with-extended-runtime-battery-pack-srv3kil\"\u003eAPC Easy UPS On-Line SRVPM3KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eLarger Easy UPS On-Line SRV models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity and format\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-6000va-230v-srv6ki\"\u003eAPC Easy UPS On-Line SRV6KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-10000va-230v-srv10ki\"\u003eAPC Easy UPS On-Line SRV10KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-6000va-230v-with-railkit-external-battery-pack-srv6krirk\"\u003eAPC Easy UPS On-Line SRV6KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-railkit-external-battery-pack-srv10krirk\"\u003eAPC Easy UPS On-Line SRV10KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eAccessories for this UPS\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWhat it is\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPC Easy UPS On-Line SRV SNMP Card (APV9601)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSNMP network management card for the Intelligent Card Slot. The correct card for Easy UPS On-Line SRV — the Smart-UPS AP9640 and AP9641 cards do not fit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPCRBCV204 (VRLA, 9 Ah, 48 V DC)\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for this model. User-replaceable. Order by this exact part number — the APCRBCV series is specific to Easy UPS On-Line and is not interchangeable with Smart-UPS APCRBC cartridges. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e to order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCurrent-generation alternative\u003c\/h4\u003e\n\u003cp\u003eSchneider has moved this range to the “-E” generation, which is a genuinely different build — higher output wattage at the same VA rating (0.9 output power factor instead of 0.8), EPO support and different battery cartridges. If you are specifying a new installation rather than matching existing equipment, look at \u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-1800w-230v-srv2ki-e\"\u003eAPC Easy UPS On-Line SRV 2000VA 1800W 230V (SRV2KI-E)\u003c\/a\u003e. Do not assume the two share specifications.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/SRV2KI\/apc-easy-ups-on-line-srv-2000va-230v\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Schneider Electric product page for the APC SRV2KI\u003c\/a\u003e — Singapore regional page. Schneider publishes the product datasheet, user guide and environmental disclosure from the document list on that page.\u003c\/p\u003e\n\u003cp\u003eSchneider serves its APC datasheet PDFs from a redirecting download host that regularly returns the wrong model's document, so we do not publish direct PDF links that we cannot verify resolve to the right part number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with the model you need and we will send the correct current-revision datasheet and user manual, along with a GST-invoiced quotation.\u003c\/p\u003e\n\u003cp\u003eEvery specification on this page was taken from Schneider Electric's own product page and its published product datasheet or user manual for this exact part number. Where Schneider's own sources disagreed, or published nothing, the field has been left out rather than estimated.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRV2KI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 2000 VA and 1600 W ratings, and how do I size it?\u003c\/h4\u003e\n\u003cp\u003eVA is apparent power, watts is real power. The SRV2KI is rated 2000 VA \/ 1600 W, an output power factor of 0.8. Add up the watts of everything you intend to protect, keep the total under 1600 W, and leave headroom — loading a UPS to 100 % shortens both runtime and battery life. As a rough Singapore rule of thumb, a 1U rack server draws 200–400 W, a 24-port PoE switch 150–400 W depending on how much PoE is actually drawn, and a small NAS 60–120 W. Send us the list and we will size it.\u003c\/p\u003e\n\u003ch4\u003eHow long will the SRV2KI run my equipment?\u003c\/h4\u003e\n\u003cp\u003eSchneider's published figure for this model is \u003cstrong\u003eup to 4 minutes at full load, and approximately 10 minutes at half load\u003c\/strong\u003e, with healthy batteries.\u003c\/p\u003e\n\u003cp\u003eWhat matters in practice is that an on-line UPS in this class is sized for a clean shutdown or a generator start, not for riding through a long outage. If you need tens of minutes, the extended-runtime power-module models with external battery packs are the right product. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with your load in watts and the autonomy you want.\u003c\/p\u003e\n\u003ch4\u003eIs the output a true sine wave, and will it work with an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eYes. Schneider's datasheet for this exact model states a \u003cstrong\u003esine wave\u003c\/strong\u003e output with 3 % voltage distortion, and the topology is \u003cstrong\u003edouble conversion on-line\u003c\/strong\u003e — the load is fed from the inverter continuously rather than being switched over when mains fails. That is what an active-PFC server or workstation PSU wants; the step-approximated output of a low-cost standby UPS is what causes those supplies to trip. Schneider does not publish a numeric transfer time for this model and we do not claim one.\u003c\/p\u003e\n\u003ch4\u003eWhat do the different Easy UPS On-Line suffixes mean?\u003c\/h4\u003e\n\u003cp\u003eThey are genuinely different builds, not marketing variants. \u003cstrong\u003eKI\u003c\/strong\u003e is a tower with internal batteries. \u003cstrong\u003eKRI\u003c\/strong\u003e is the 2U rackmount build of the same capacity — different outlet count and dimensions, so do not read tower specs onto a rack unit. \u003cstrong\u003ePM…IL\u003c\/strong\u003e is an extended-runtime power module with no internal batteries, supplied with an external pack. \u003cstrong\u003e-E\u003c\/strong\u003e is the newer generation with a 0.9 output power factor, so an SRV3KI-E delivers 2700 W where this generation delivers 2400 W at the same 3 kVA. \u003cstrong\u003eRK\u003c\/strong\u003e means the rail kit is included in the part number.\u003c\/p\u003e\n\u003ch4\u003eWhich replacement battery cartridge does the SRV2KI take, and can I change it myself?\u003c\/h4\u003e\n\u003cp\u003eThe cartridge is \u003cstrong\u003eAPCRBCV204 (VRLA, 9 Ah, 48 V DC)\u003c\/strong\u003e. It is user-replaceable, and the batteries are the consumable part of any UPS — expect 3–5 years in a well-ventilated room, less in a hot cabinet, which is the usual Singapore constraint. Order by that exact part number: the \u003cstrong\u003eAPCRBCV\u003c\/strong\u003e series belongs to Easy UPS On-Line and is \u003cem\u003enot\u003c\/em\u003e interchangeable with the \u003cstrong\u003eAPCRBC\u003c\/strong\u003e cartridges used by Smart-UPS, even where the voltage looks similar. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e to order one.\u003c\/p\u003e\n\u003ch4\u003eCan the SRV2KI be rack mounted?\u003c\/h4\u003e\n\u003cp\u003eNo. This is a tower unit at 238 mm (H) × 145 mm (W) × 400 mm (D). Schneider builds the rackmount version as a separate part number — the 2U SRVxKRI family listed in the ordering block above. The two are not convertible, and their outlet counts and dimensions differ, so pick the form factor at the point of order.\u003c\/p\u003e\n\u003ch4\u003eHow do I monitor it over the network?\u003c\/h4\u003e\n\u003cp\u003eFit the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e in the UPS Intelligent Card Slot. That is the Easy UPS On-Line card — the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will not work here. Without a card you still get USB and RS-232 for a direct shutdown link to one host, with PowerChute Serial Shutdown or PowerChute Business Edition. Note that Schneider has discontinued the APV9601; ask us about current stock and the AP9544 successor before you commit to a monitoring design.\u003c\/p\u003e\n\u003ch4\u003eIs the SRV2KI covered by warranty in Singapore?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC SRV2KI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRV2KI with a 2-year manufacturer warranty. Schneider publishes a single worldwide figure of “2 years repair or replace” for the Easy UPS On-Line SRV range — there is no separate European and rest-of-world split on this family, so the term above is the one that applies in Singapore.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bzQk-YuLvCM\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039227248804,"sku":"SRV2KI","price":995.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-easy-ups-on-line-srv-2000va-230v-srv2ki-865185.jpg?v=1702980106"},{"product_id":"apc-easy-ups-on-line-srv-3000va-230v-srv3ki","title":"APC Easy UPS On-Line SRV 3000VA 230V","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRV 3000VA 230V (SRV3KI) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDouble-Conversion On-Line Protection for Singapore's 230 V \/ 50 Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC SRV3KI is a \u003cstrong\u003edouble-conversion on-line UPS\u003c\/strong\u003e: incoming mains is rectified to DC and rebuilt as a clean sine wave output, so the connected load never sees the supply it is actually plugged into. That matters on the Singapore grid, where the day-to-day problem is rarely a full blackout and much more often the voltage sag that arrives with an afternoon thunderstorm, or the disturbance from a large motor load elsewhere in the building. The unit rides those out on its inverter, holding a 160–280 V full-load input window before it needs the battery at all.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e3000 VA of Protected Capacity, 2400 W of Real Power\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRated at \u003cstrong\u003e3000 VA \/ 2400 W\u003c\/strong\u003e, the SRV3KI is sized for a loaded comms cabinet, a small server room or a rack of network and storage equipment. Size against the watts figure rather than the VA figure — servers, switches and storage are watts loads — and leave headroom rather than running it hard, which costs you both runtime and battery life. On-line efficiency is 88 % at full load, and output distortion is held to 3 %, which is what an active-PFC server power supply expects to see.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTower Format with Six C13 and One C19 Outlet\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA tower at 336 mm (H) × 190 mm (W) × 425 mm (D) and 26.8 kg net \/ 29 kg shipping, the SRV3KI suits an SME office, a home office or a floor comms position where there is no rack to mount into. Output is 6 × IEC 60320 C13 + 1 × IEC 60320 C19 (all battery backup and surge protected), and every one of them carries battery backup and surge protection — there is no surge-only bank to accidentally plug a server into. Input connection is IEC 60320 C20 inlet — a 16 A inlet, not the 10 A C14 used on the 1 kVA and 2 kVA models.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBatteries, Service Life and Singapore's Heat\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInternal batteries are maintenance-free sealed VRLA (72 V DC, from 6 × 12 V 9 Ah blocks), recharging in 4 hours, with an expected service life of 3–5 years. Heat is what actually kills UPS batteries, and a poorly ventilated cabinet in Singapore's climate will take years off them — the unit is rated for 0 °C to 40 °C and runs at 50 dBA, so give it airflow. When the time comes the cartridge is \u003cstrong\u003eAPCRBCV205 (VRLA, 9 Ah, 72 V DC)\u003c\/strong\u003e and it is user-replaceable, with battery condition readable from the front-panel LCD.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBuy the APC SRV3KI in Singapore with Local Warranty and GST Invoice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the APC SRV3KI from Singapore with a GST invoice and local warranty support, backed by APC's 2-year manufacturer warranty. Tell us the load you need to protect — in watts, and how long you need it to stay up — and we will size the unit, the cartridge and the network card properly rather than sell you the nearest number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRV3KI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRV3KI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSRV3KI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \/ Series\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric — Easy UPS On-Line SRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider product name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line, 3kVA\/2400W, Tower, 230V, 6x IEC C13 + 1x IEC C19 outlets, Intelligent Card Slot, LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal, configurable for 220 \/ 230 \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz ± 3 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage distortion\u003c\/td\u003e\n\u003ctd\u003e3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3 : 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-line efficiency\u003c\/td\u003e\n\u003ctd\u003e88 % at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput connections\u003c\/td\u003e\n\u003ctd\u003e6 × IEC 60320 C13 + 1 × IEC 60320 C19 (all battery backup and surge protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e600 Joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal bypass\u003c\/td\u003e\n\u003ctd\u003eAutomatic and manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range\u003c\/td\u003e\n\u003ctd\u003e160–280 V at full load; 110–285 V at half load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C20 inlet — a 16 A inlet, not the 10 A C14 used on the 1 kVA and 2 kVA models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed valve-regulated lead-acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e72 V DC, from 6 × 12 V 9 Ah blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement battery cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBCV205 (VRLA, 9 Ah, 72 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical recharge time\u003c\/td\u003e\n\u003ctd\u003e4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected battery life\u003c\/td\u003e\n\u003ctd\u003e3–5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal battery pack\u003c\/td\u003e\n\u003ctd\u003eNot supported on this model — internal batteries only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eYes (USB cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial port\u003c\/td\u003e\n\u003ctd\u003eRS-232, DB-9 (configuration cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard slot\u003c\/td\u003e\n\u003ctd\u003e1 × Intelligent Card Slot (Schneider’s term — not a Smart-UPS “SmartSlot”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork management card\u003c\/td\u003e\n\u003ctd\u003eAPV9601 — APC Easy UPS On-Line SRV SNMP card (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutdown software\u003c\/td\u003e\n\u003ctd\u003eCompatible with PowerChute Serial Shutdown and PowerChute Business Edition — Schneider FAQ FA315835 lists SRV models of 3 kVA and below as supported over USB or serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eNot available on this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm\u003c\/td\u003e\n\u003ctd\u003eOn battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e336 mm (H) × 190 mm (W) × 425 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e26.8 kg net \/ 29 kg shipping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity\u003c\/td\u003e\n\u003ctd\u003e0–95 % relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating elevation\u003c\/td\u003e\n\u003ctd\u003e0–3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible noise\u003c\/td\u003e\n\u003ctd\u003e50 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications and standards\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, EAC, TISI; EN\/IEC 62040-1, EN\/IEC 62040-2; EU and China RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe SRV3KI provides \u003cstrong\u003e6 × IEC 60320 C13 + 1 × IEC 60320 C19 (all battery backup and surge protected)\u003c\/strong\u003e. Every outlet is fed from the inverter, so all of them carry battery backup and surge protection — there is no surge-only bank on this model. Rated capacity is 3000 VA \/ 2400 W: size the load against the \u003cstrong\u003e2400 W figure\u003c\/strong\u003e, because a server, switch or storage array is a watts load, not a VA load.\u003c\/p\u003e\n\u003cp\u003eThe single IEC C19 outlet is the one to reserve for a higher-draw device — a blade chassis, a large PSU or a rack PDU feeding a sub-bank. Note this model has \u003cstrong\u003eone\u003c\/strong\u003e C19, not two.\u003c\/p\u003e\n\u003ch4\u003eInput and circuit requirements\u003c\/h4\u003e\n\u003cp\u003eInput connection is \u003cstrong\u003eIEC 60320 C20 inlet — a 16 A inlet, not the 10 A C14 used on the 1 kVA and 2 kVA models\u003c\/strong\u003e. Singapore mains is 230 V \/ 50 Hz, which sits comfortably inside this unit's 160–280 V full-load input window, and the on-line inverter regenerates the output waveform continuously rather than switching to battery for every dip — useful during the voltage sags that accompany a thunderstorm on the PUB grid.\u003c\/p\u003e\n\u003ch4\u003eFootprint\u003c\/h4\u003e\n\u003cp\u003eThis is a \u003cstrong\u003etower\u003c\/strong\u003e unit at 336 mm (H) × 190 mm (W) × 425 mm (D) and it is not rack-mountable. The rackmount equivalent at the same capacity is a separate part number — see the ordering block below.\u003c\/p\u003e\n\u003ch4\u003eBatteries and runtime\u003c\/h4\u003e\n\u003cp\u003eThe SRV3KI runs on sealed maintenance-free VRLA batteries at 72 V DC, from 6 × 12 V 9 Ah blocks, and recharges in 4 hours. Expected service life is 3–5 years in a temperature-controlled room; Singapore's ambient heat and humidity are the main things that shorten it, so a comms cabinet with airflow is worth the effort.\u003c\/p\u003e\n\u003cp\u003eSchneider publishes no runtime-at-load table for this model that we could verify against two independent sources, so none is quoted here. Send us your load in watts and the autonomy you need — \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e — and we will size it properly rather than guess.\u003c\/p\u003e\n\u003cp\u003eThe matching replacement battery cartridge is \u003cstrong\u003eAPCRBCV205 (VRLA, 9 Ah, 72 V DC)\u003c\/strong\u003e. Note this is the APCRBCV series used by Easy UPS On-Line, which is a different range from the APCRBC cartridges used by Smart-UPS — do not substitute across the two.\u003c\/p\u003e\n\u003cp\u003eThis model does \u003cstrong\u003enot\u003c\/strong\u003e accept an external battery pack. If you need longer autonomy at this capacity, the extended-runtime power-module models are the correct product — they are listed in the ordering block below.\u003c\/p\u003e\n\u003ch4\u003eManagement options\u003c\/h4\u003e\n\u003cp\u003eThe SRV3KI has a USB port, an RS-232 DB-9 serial port and one \u003cstrong\u003eIntelligent Card Slot\u003c\/strong\u003e. Schneider's card for that slot is the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e. The Easy UPS On-Line SRV range uses a different card family from Smart-UPS: the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will \u003cstrong\u003enot\u003c\/strong\u003e work in this UPS.\u003c\/p\u003e\n\u003cp\u003eFor direct USB or serial shutdown of a single host, Schneider's FAQ FA315835 lists SRV models of 3 kVA and below as supported by PowerChute Serial Shutdown and PowerChute Business Edition. PowerChute itself is a Schneider download rather than a licence sold with the UPS — ask us if you want the current version confirmed for your operating system before you commission.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 × IEC C13 to Schuko power cable\u003c\/li\u003e\n\u003cli\u003e1 × IEC C13 to C14 power cable\u003c\/li\u003e\n\u003cli\u003e1 × USB cable\u003c\/li\u003e\n\u003cli\u003e1 × RS-232 configuration cable\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's documented carton contents list an IEC C13-to-Schuko (European) cord. In Singapore these units are normally fed from a rack PDU or a locally fitted BS 1363 cord — tell us how you intend to power it and we will confirm what ships in the Singapore carton and supply the right cordage with the order.\u003c\/p\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — tower models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-230v-srv1ki\"\u003eAPC Easy UPS On-Line SRV1KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-srv2ki\"\u003eAPC Easy UPS On-Line SRV2KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRV3KI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — rackmount 2U models (supplied with SRVRK1 rail kit)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri\"\u003eAPC Easy UPS On-Line SRV1KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri\"\u003eAPC Easy UPS On-Line SRV2KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri\"\u003eAPC Easy UPS On-Line SRV3KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eExtended-runtime models (no internal battery, external pack supplied)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery pack\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-external-battery-pack-srv3kri\"\u003eAPC Easy UPS On-Line SRVPM1KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · SRV36BP-9A (36 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-with-extended-runtime-battery-pack-srv2kil\"\u003eAPC Easy UPS On-Line SRVPM2KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-with-extended-runtime-battery-pack-srv3kil\"\u003eAPC Easy UPS On-Line SRVPM3KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eLarger Easy UPS On-Line SRV models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity and format\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-6000va-230v-srv6ki\"\u003eAPC Easy UPS On-Line SRV6KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-10000va-230v-srv10ki\"\u003eAPC Easy UPS On-Line SRV10KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-6000va-230v-with-railkit-external-battery-pack-srv6krirk\"\u003eAPC Easy UPS On-Line SRV6KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-railkit-external-battery-pack-srv10krirk\"\u003eAPC Easy UPS On-Line SRV10KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eAccessories for this UPS\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWhat it is\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPC Easy UPS On-Line SRV SNMP Card (APV9601)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSNMP network management card for the Intelligent Card Slot. The correct card for Easy UPS On-Line SRV — the Smart-UPS AP9640 and AP9641 cards do not fit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPCRBCV205 (VRLA, 9 Ah, 72 V DC)\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for this model. User-replaceable. Order by this exact part number — the APCRBCV series is specific to Easy UPS On-Line and is not interchangeable with Smart-UPS APCRBC cartridges. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e to order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCurrent-generation alternative\u003c\/h4\u003e\n\u003cp\u003eSchneider has moved this range to the “-E” generation, which is a genuinely different build — higher output wattage at the same VA rating (0.9 output power factor instead of 0.8), EPO support and different battery cartridges. If you are specifying a new installation rather than matching existing equipment, look at \u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-2700w-230v-srv3ki-e\"\u003eAPC Easy UPS On-Line SRV 3000VA 2700W 230V (SRV3KI-E)\u003c\/a\u003e. Do not assume the two share specifications.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/SRV3KI\/apc-easy-ups-on-line-srv-3000va-230v.\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Schneider Electric product page for the APC SRV3KI\u003c\/a\u003e — Singapore regional page. Schneider publishes the product datasheet, user guide and environmental disclosure from the document list on that page.\u003c\/p\u003e\n\u003cp\u003eSchneider serves its APC datasheet PDFs from a redirecting download host that regularly returns the wrong model's document, so we do not publish direct PDF links that we cannot verify resolve to the right part number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with the model you need and we will send the correct current-revision datasheet and user manual, along with a GST-invoiced quotation.\u003c\/p\u003e\n\u003cp\u003eEvery specification on this page was taken from Schneider Electric's own product page and its published product datasheet or user manual for this exact part number. Where Schneider's own sources disagreed, or published nothing, the field has been left out rather than estimated.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRV3KI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 3000 VA and 2400 W ratings, and how do I size it?\u003c\/h4\u003e\n\u003cp\u003eVA is apparent power, watts is real power. The SRV3KI is rated 3000 VA \/ 2400 W, an output power factor of 0.8. Add up the watts of everything you intend to protect, keep the total under 2400 W, and leave headroom — loading a UPS to 100 % shortens both runtime and battery life. As a rough Singapore rule of thumb, a 1U rack server draws 200–400 W, a 24-port PoE switch 150–400 W depending on how much PoE is actually drawn, and a small NAS 60–120 W. Send us the list and we will size it.\u003c\/p\u003e\n\u003ch4\u003eHow long will the SRV3KI run my equipment?\u003c\/h4\u003e\n\u003cp\u003eSchneider does not publish a runtime-at-load table for this model that we could verify against two independent official sources, so we do not quote minutes here rather than invent them.\u003c\/p\u003e\n\u003cp\u003eWhat matters in practice is that an on-line UPS in this class is sized for a clean shutdown or a generator start, not for riding through a long outage. If you need tens of minutes, the extended-runtime power-module models with external battery packs are the right product. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with your load in watts and the autonomy you want.\u003c\/p\u003e\n\u003ch4\u003eIs the output a true sine wave, and will it work with an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eYes. Schneider's datasheet for this exact model states a \u003cstrong\u003esine wave\u003c\/strong\u003e output with 3 % voltage distortion, and the topology is \u003cstrong\u003edouble conversion on-line\u003c\/strong\u003e — the load is fed from the inverter continuously rather than being switched over when mains fails. That is what an active-PFC server or workstation PSU wants; the step-approximated output of a low-cost standby UPS is what causes those supplies to trip. Schneider does not publish a numeric transfer time for this model and we do not claim one.\u003c\/p\u003e\n\u003ch4\u003eWhat do the different Easy UPS On-Line suffixes mean?\u003c\/h4\u003e\n\u003cp\u003eThey are genuinely different builds, not marketing variants. \u003cstrong\u003eKI\u003c\/strong\u003e is a tower with internal batteries. \u003cstrong\u003eKRI\u003c\/strong\u003e is the 2U rackmount build of the same capacity — different outlet count and dimensions, so do not read tower specs onto a rack unit. \u003cstrong\u003ePM…IL\u003c\/strong\u003e is an extended-runtime power module with no internal batteries, supplied with an external pack. \u003cstrong\u003e-E\u003c\/strong\u003e is the newer generation with a 0.9 output power factor, so an SRV3KI-E delivers 2700 W where this generation delivers 2400 W at the same 3 kVA. \u003cstrong\u003eRK\u003c\/strong\u003e means the rail kit is included in the part number.\u003c\/p\u003e\n\u003ch4\u003eWhich replacement battery cartridge does the SRV3KI take, and can I change it myself?\u003c\/h4\u003e\n\u003cp\u003eThe cartridge is \u003cstrong\u003eAPCRBCV205 (VRLA, 9 Ah, 72 V DC)\u003c\/strong\u003e. It is user-replaceable, and the batteries are the consumable part of any UPS — expect 3–5 years in a well-ventilated room, less in a hot cabinet, which is the usual Singapore constraint. Order by that exact part number: the \u003cstrong\u003eAPCRBCV\u003c\/strong\u003e series belongs to Easy UPS On-Line and is \u003cem\u003enot\u003c\/em\u003e interchangeable with the \u003cstrong\u003eAPCRBC\u003c\/strong\u003e cartridges used by Smart-UPS, even where the voltage looks similar. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e to order one.\u003c\/p\u003e\n\u003ch4\u003eCan the SRV3KI be rack mounted?\u003c\/h4\u003e\n\u003cp\u003eNo. This is a tower unit at 336 mm (H) × 190 mm (W) × 425 mm (D). Schneider builds the rackmount version as a separate part number — the 2U SRVxKRI family listed in the ordering block above. The two are not convertible, and their outlet counts and dimensions differ, so pick the form factor at the point of order.\u003c\/p\u003e\n\u003ch4\u003eHow do I monitor it over the network?\u003c\/h4\u003e\n\u003cp\u003eFit the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e in the UPS Intelligent Card Slot. That is the Easy UPS On-Line card — the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will not work here. Without a card you still get USB and RS-232 for a direct shutdown link to one host, with PowerChute Serial Shutdown or PowerChute Business Edition. Note that Schneider has discontinued the APV9601; ask us about current stock and the AP9544 successor before you commit to a monitoring design.\u003c\/p\u003e\n\u003ch4\u003eIs the SRV3KI covered by warranty in Singapore?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC SRV3KI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRV3KI with a 2-year manufacturer warranty. Schneider publishes a single worldwide figure of “2 years repair or replace” for the Easy UPS On-Line SRV range — there is no separate European and rest-of-world split on this family, so the term above is the one that applies in Singapore.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bzQk-YuLvCM\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039243042980,"sku":"SRV3KI","price":1445.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-easy-ups-on-line-srv-3000va-230v-srv3ki-479242.jpg?v=1702980114"},{"product_id":"apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri","title":"APC Easy UPS On-Line SRV 1000VA RM 230V with Rail Kit","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRV 1000VA RM 230V with Rail Kit (SRV1KRI) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDouble-Conversion On-Line Protection for Singapore's 230 V \/ 50 Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC SRV1KRI is a \u003cstrong\u003edouble-conversion on-line UPS\u003c\/strong\u003e: incoming mains is rectified to DC and rebuilt as a clean sine wave output, so the connected load never sees the supply it is actually plugged into. That matters on the Singapore grid, where the day-to-day problem is rarely a full blackout and much more often the voltage sag that arrives with an afternoon thunderstorm, or the disturbance from a large motor load elsewhere in the building. The unit rides those out on its inverter, holding a 160–280 V full-load input window before it needs the battery at all.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e1000 VA of Protected Capacity, 800 W of Real Power\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRated at \u003cstrong\u003e1000 VA \/ 800 W\u003c\/strong\u003e, the SRV1KRI is sized for a small comms cabinet, a single server or a workgroup of network equipment. Size against the watts figure rather than the VA figure — servers, switches and storage are watts loads — and leave headroom rather than running it hard, which costs you both runtime and battery life. On-line efficiency is 88 % at full load, and output distortion is held to 3 %, which is what an active-PFC server power supply expects to see.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e2U Rackmount with SRVRK1 Rail Kit for Your Comms Cabinet\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis build occupies \u003cstrong\u003e2U\u003c\/strong\u003e and measures 86 mm (H) × 437 mm (W) × 312 mm (D), with a chassis depth of \u003cstrong\u003e312 mm\u003c\/strong\u003e — the number to check against your cabinet before you order. Schneider sells the bare UPS as a “W\/O rail kit” part number; this SourceIT bundle adds the \u003cstrong\u003eSRVRK1\u003c\/strong\u003e 19-inch rail kit, rated to 60 kg, as a separate carton, and the UPS carton itself contains rack mounting brackets. Output is 3 × IEC 60320 C13 (all battery backup and surge protected).\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBatteries, Service Life and Singapore's Heat\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInternal batteries are maintenance-free sealed VRLA (24 V DC), recharging in 4 hours, with an expected service life of 3–5 years. Heat is what actually kills UPS batteries, and a poorly ventilated cabinet in Singapore's climate will take years off them — the unit is rated for 0 °C to 40 °C and runs at 50 dBA, so give it airflow. When the time comes the cartridge is \u003cstrong\u003eAPCRBCV200 (VRLA, 9 Ah, 24 V DC)\u003c\/strong\u003e and it is user-replaceable, with battery condition readable from the front-panel LCD.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBuy the APC SRV1KRI in Singapore with Local Warranty and GST Invoice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the APC SRV1KRI from Singapore with a GST invoice and local warranty support, backed by APC's 2-year manufacturer warranty. Tell us the load you need to protect — in watts, and how long you need it to stay up — and we will size the unit, the cartridge and the network card properly rather than sell you the nearest number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRV1KRI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRV1KRI + SRVRK1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSRV1KRI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \/ Series\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric — Easy UPS On-Line SRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider product name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line, 1000VA\/800W, Rackmount 2U, 230V, 3x IEC C13 outlets, Intelligent Card Slot, LCD, W\/O rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eRackmount, 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack height\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal, configurable for 220 \/ 230 \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz ± 3 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage distortion\u003c\/td\u003e\n\u003ctd\u003e3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3 : 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-line efficiency\u003c\/td\u003e\n\u003ctd\u003e88 % at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput connections\u003c\/td\u003e\n\u003ctd\u003e3 × IEC 60320 C13 (all battery backup and surge protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e600 Joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range\u003c\/td\u003e\n\u003ctd\u003e160–280 V at full load; 110–285 V at half load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet, 1.5 m input cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed valve-regulated lead-acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement battery cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBCV200 (VRLA, 9 Ah, 24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical recharge time\u003c\/td\u003e\n\u003ctd\u003e4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected battery life\u003c\/td\u003e\n\u003ctd\u003e3–5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal battery pack\u003c\/td\u003e\n\u003ctd\u003eNot supported on this model — internal batteries only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eYes (USB cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial port\u003c\/td\u003e\n\u003ctd\u003eRS-232, DB-9 (configuration cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard slot\u003c\/td\u003e\n\u003ctd\u003e1 × Intelligent Card Slot (Schneider’s term — not a Smart-UPS “SmartSlot”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork management card\u003c\/td\u003e\n\u003ctd\u003eAPV9601 — APC Easy UPS On-Line SRV SNMP card (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutdown software\u003c\/td\u003e\n\u003ctd\u003eCompatible with PowerChute Serial Shutdown and PowerChute Business Edition — Schneider FAQ FA315835 lists SRV models of 3 kVA and below as supported over USB or serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eNot available on this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm\u003c\/td\u003e\n\u003ctd\u003eOn battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86 mm (H) × 437 mm (W) × 312 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e11.0 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity\u003c\/td\u003e\n\u003ctd\u003e0–95 % relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating elevation\u003c\/td\u003e\n\u003ctd\u003e0–3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible noise\u003c\/td\u003e\n\u003ctd\u003e50 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications and standards\u003c\/td\u003e\n\u003ctd\u003eCE, EAC, TISI; EN\/IEC 62040-1, EN\/IEC 62040-2; RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eSRVRK1 Rail Kit (supplied with this bundle)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRVRK1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV 19-inch rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS Rackmount SRV and SRVL models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum equipment weight\u003c\/td\u003e\n\u003ctd\u003e60 kg (132 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported equipment width\u003c\/td\u003e\n\u003ctd\u003e43–45 cm (16.75–17.7 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider publishes two contradictory cabinet-depth figures for the SRVRK1 across its own regional catalogues (700 mm on some, 780 mm on others), so no depth rating is quoted here. The figure that actually governs your install is the UPS chassis depth of 312 mm, given above.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe SRV1KRI provides \u003cstrong\u003e3 × IEC 60320 C13 (all battery backup and surge protected)\u003c\/strong\u003e. Every outlet is fed from the inverter, so all of them carry battery backup and surge protection — there is no surge-only bank on this model. Rated capacity is 1000 VA \/ 800 W: size the load against the \u003cstrong\u003e800 W figure\u003c\/strong\u003e, because a server, switch or storage array is a watts load, not a VA load.\u003c\/p\u003e\n\u003ch4\u003eInput and circuit requirements\u003c\/h4\u003e\n\u003cp\u003eInput connection is \u003cstrong\u003eIEC 60320 C14 inlet, 1.5 m input cord\u003c\/strong\u003e. Singapore mains is 230 V \/ 50 Hz, which sits comfortably inside this unit's 160–280 V full-load input window, and the on-line inverter regenerates the output waveform continuously rather than switching to battery for every dip — useful during the voltage sags that accompany a thunderstorm on the PUB grid.\u003c\/p\u003e\n\u003ch4\u003eRack space and depth\u003c\/h4\u003e\n\u003cp\u003eThis is a \u003cstrong\u003e2U rackmount\u003c\/strong\u003e unit, 86 mm (H) × 437 mm (W) × 312 mm (D), and it is rack-only — there is no tower conversion. The number that decides whether it fits your cabinet is the chassis depth of \u003cstrong\u003e312 mm\u003c\/strong\u003e. At 312 mm it suits a standard comms cabinet comfortably.\u003c\/p\u003e\n\u003cp\u003eSchneider's own part number for this UPS ends in “W\/O rail kit” — the bare SRV1KRI does not include rails. This SourceIT listing is the bundle: the UPS plus a separate \u003cstrong\u003eSRVRK1\u003c\/strong\u003e 19-inch rail kit carton, rated to 60 kg. The UPS carton itself also contains rack mounting brackets.\u003c\/p\u003e\n\u003ch4\u003eBatteries and runtime\u003c\/h4\u003e\n\u003cp\u003eThe SRV1KRI runs on sealed maintenance-free VRLA batteries at 24 V DC, and recharges in 4 hours. Expected service life is 3–5 years in a temperature-controlled room; Singapore's ambient heat and humidity are the main things that shorten it, so a comms cabinet with airflow is worth the effort.\u003c\/p\u003e\n\u003cp\u003eSchneider publishes no runtime-at-load table for this model that we could verify against two independent sources, so none is quoted here. Send us your load in watts and the autonomy you need — \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e — and we will size it properly rather than guess.\u003c\/p\u003e\n\u003cp\u003eThe matching replacement battery cartridge is \u003cstrong\u003eAPCRBCV200 (VRLA, 9 Ah, 24 V DC)\u003c\/strong\u003e. Note this is the APCRBCV series used by Easy UPS On-Line, which is a different range from the APCRBC cartridges used by Smart-UPS — do not substitute across the two.\u003c\/p\u003e\n\u003cp\u003eThis model does \u003cstrong\u003enot\u003c\/strong\u003e accept an external battery pack. If you need longer autonomy at this capacity, the extended-runtime power-module models are the correct product — they are listed in the ordering block below.\u003c\/p\u003e\n\u003ch4\u003eManagement options\u003c\/h4\u003e\n\u003cp\u003eThe SRV1KRI has a USB port, an RS-232 DB-9 serial port and one \u003cstrong\u003eIntelligent Card Slot\u003c\/strong\u003e. Schneider's card for that slot is the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e. The Easy UPS On-Line SRV range uses a different card family from Smart-UPS: the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will \u003cstrong\u003enot\u003c\/strong\u003e work in this UPS.\u003c\/p\u003e\n\u003cp\u003eFor direct USB or serial shutdown of a single host, Schneider's FAQ FA315835 lists SRV models of 3 kVA and below as supported by PowerChute Serial Shutdown and PowerChute Business Edition. PowerChute itself is a Schneider download rather than a licence sold with the UPS — ask us if you want the current version confirmed for your operating system before you commission.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 × RS-232 signalling cable\u003c\/li\u003e\n\u003cli\u003e1 × USB cable\u003c\/li\u003e\n\u003cli\u003e1 × CD with software\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003cli\u003eRack mounting brackets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — tower models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-230v-srv1ki\"\u003eAPC Easy UPS On-Line SRV1KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-srv2ki\"\u003eAPC Easy UPS On-Line SRV2KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-srv3ki\"\u003eAPC Easy UPS On-Line SRV3KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — rackmount 2U models (supplied with SRVRK1 rail kit)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRV1KRI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri\"\u003eAPC Easy UPS On-Line SRV2KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri\"\u003eAPC Easy UPS On-Line SRV3KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eExtended-runtime models (no internal battery, external pack supplied)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery pack\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-external-battery-pack-srv3kri\"\u003eAPC Easy UPS On-Line SRVPM1KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · SRV36BP-9A (36 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-with-extended-runtime-battery-pack-srv2kil\"\u003eAPC Easy UPS On-Line SRVPM2KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-with-extended-runtime-battery-pack-srv3kil\"\u003eAPC Easy UPS On-Line SRVPM3KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eLarger Easy UPS On-Line SRV models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity and format\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-6000va-230v-srv6ki\"\u003eAPC Easy UPS On-Line SRV6KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-10000va-230v-srv10ki\"\u003eAPC Easy UPS On-Line SRV10KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-6000va-230v-with-railkit-external-battery-pack-srv6krirk\"\u003eAPC Easy UPS On-Line SRV6KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-railkit-external-battery-pack-srv10krirk\"\u003eAPC Easy UPS On-Line SRV10KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eAccessories for this UPS\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWhat it is\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPC Easy UPS On-Line SRV SNMP Card (APV9601)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSNMP network management card for the Intelligent Card Slot. The correct card for Easy UPS On-Line SRV — the Smart-UPS AP9640 and AP9641 cards do not fit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPCRBCV200 (VRLA, 9 Ah, 24 V DC)\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for this model. User-replaceable. Order by this exact part number — the APCRBCV series is specific to Easy UPS On-Line and is not interchangeable with Smart-UPS APCRBC cartridges. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e to order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVRK1\u003c\/td\u003e\n\u003ctd\u003e19-inch rail kit, rated to 60 kg. Already included in this bundle as a separate carton.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCurrent-generation alternative\u003c\/h4\u003e\n\u003cp\u003eSchneider has moved this range to the “-E” generation, which is a genuinely different build — higher output wattage at the same VA rating (0.9 output power factor instead of 0.8), EPO support and different battery cartridges. If you are specifying a new installation rather than matching existing equipment, look at \u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-battery-pack-rail-kit-srv1krilrk-e\"\u003eAPC Easy UPS SRV 1000VA RM 230V with Battery \u0026amp; Rail Kit (SRV1KRILRK-E)\u003c\/a\u003e. Do not assume the two share specifications.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/SRV1KRI\/apc-easy-ups-online-1000va-800w-rackmount-2u-230v-3x-iec-c13-outlets-intelligent-card-slot-lcd-w-o-rail-kit\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Schneider Electric product page for the APC SRV1KRI\u003c\/a\u003e — Singapore regional page. Schneider publishes the product datasheet, user guide and environmental disclosure from the document list on that page.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/SRVRK1\/apc-easy-ups-online-srv-19-rail-kit-780mm-depth\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Schneider Electric product page for the SRVRK1 rail kit\u003c\/a\u003e supplied with this bundle.\u003c\/p\u003e\n\u003cp\u003eSchneider serves its APC datasheet PDFs from a redirecting download host that regularly returns the wrong model's document, so we do not publish direct PDF links that we cannot verify resolve to the right part number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with the model you need and we will send the correct current-revision datasheet and user manual, along with a GST-invoiced quotation.\u003c\/p\u003e\n\u003cp\u003eEvery specification on this page was taken from Schneider Electric's own product page and its published product datasheet or user manual for this exact part number. Where Schneider's own sources disagreed, or published nothing, the field has been left out rather than estimated.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRV1KRI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 1000 VA and 800 W ratings, and how do I size it?\u003c\/h4\u003e\n\u003cp\u003eVA is apparent power, watts is real power. The SRV1KRI is rated 1000 VA \/ 800 W, an output power factor of 0.8. Add up the watts of everything you intend to protect, keep the total under 800 W, and leave headroom — loading a UPS to 100 % shortens both runtime and battery life. As a rough Singapore rule of thumb, a 1U rack server draws 200–400 W, a 24-port PoE switch 150–400 W depending on how much PoE is actually drawn, and a small NAS 60–120 W. Send us the list and we will size it.\u003c\/p\u003e\n\u003ch4\u003eHow long will the SRV1KRI run my equipment?\u003c\/h4\u003e\n\u003cp\u003eSchneider does not publish a runtime-at-load table for this model that we could verify against two independent official sources, so we do not quote minutes here rather than invent them.\u003c\/p\u003e\n\u003cp\u003eWhat matters in practice is that an on-line UPS in this class is sized for a clean shutdown or a generator start, not for riding through a long outage. If you need tens of minutes, the extended-runtime power-module models with external battery packs are the right product. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with your load in watts and the autonomy you want.\u003c\/p\u003e\n\u003ch4\u003eIs the output a true sine wave, and will it work with an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eYes. Schneider's datasheet for this exact model states a \u003cstrong\u003esine wave\u003c\/strong\u003e output with 3 % voltage distortion, and the topology is \u003cstrong\u003edouble conversion on-line\u003c\/strong\u003e — the load is fed from the inverter continuously rather than being switched over when mains fails. That is what an active-PFC server or workstation PSU wants; the step-approximated output of a low-cost standby UPS is what causes those supplies to trip. Schneider does not publish a numeric transfer time for this model and we do not claim one.\u003c\/p\u003e\n\u003ch4\u003eWhat do the different Easy UPS On-Line suffixes mean?\u003c\/h4\u003e\n\u003cp\u003eThey are genuinely different builds, not marketing variants. \u003cstrong\u003eKI\u003c\/strong\u003e is a tower with internal batteries. \u003cstrong\u003eKRI\u003c\/strong\u003e is the 2U rackmount build of the same capacity — different outlet count and dimensions, so do not read tower specs onto a rack unit. \u003cstrong\u003ePM…IL\u003c\/strong\u003e is an extended-runtime power module with no internal batteries, supplied with an external pack. \u003cstrong\u003e-E\u003c\/strong\u003e is the newer generation with a 0.9 output power factor, so an SRV3KI-E delivers 2700 W where this generation delivers 2400 W at the same 3 kVA. \u003cstrong\u003eRK\u003c\/strong\u003e means the rail kit is included in the part number.\u003c\/p\u003e\n\u003ch4\u003eWhich replacement battery cartridge does the SRV1KRI take, and can I change it myself?\u003c\/h4\u003e\n\u003cp\u003eThe cartridge is \u003cstrong\u003eAPCRBCV200 (VRLA, 9 Ah, 24 V DC)\u003c\/strong\u003e. It is user-replaceable, and the batteries are the consumable part of any UPS — expect 3–5 years in a well-ventilated room, less in a hot cabinet, which is the usual Singapore constraint. Order by that exact part number: the \u003cstrong\u003eAPCRBCV\u003c\/strong\u003e series belongs to Easy UPS On-Line and is \u003cem\u003enot\u003c\/em\u003e interchangeable with the \u003cstrong\u003eAPCRBC\u003c\/strong\u003e cartridges used by Smart-UPS, even where the voltage looks similar. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e to order one.\u003c\/p\u003e\n\u003ch4\u003eHow much rack space does it need, and are the rails included?\u003c\/h4\u003e\n\u003cp\u003eIt occupies \u003cstrong\u003e2U\u003c\/strong\u003e and the chassis is \u003cstrong\u003e312 mm deep\u003c\/strong\u003e. Schneider's part number for the bare UPS ends in “W\/O rail kit”, so the rails are a separate item — and they are included in this SourceIT bundle as an \u003cstrong\u003eSRVRK1\u003c\/strong\u003e carton alongside the UPS. The UPS carton also contains rack mounting brackets. The rail kit is rated to 60 kg, comfortably above this unit's net weight of 11.0 kg. At 312 mm it fits a standard comms cabinet.\u003c\/p\u003e\n\u003ch4\u003eHow do I monitor it over the network?\u003c\/h4\u003e\n\u003cp\u003eFit the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e in the UPS Intelligent Card Slot. That is the Easy UPS On-Line card — the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will not work here. Without a card you still get USB and RS-232 for a direct shutdown link to one host, with PowerChute Serial Shutdown or PowerChute Business Edition. Note that Schneider has discontinued the APV9601; ask us about current stock and the AP9544 successor before you commit to a monitoring design.\u003c\/p\u003e\n\u003ch4\u003eIs the SRV1KRI covered by warranty in Singapore?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC SRV1KRI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRV1KRI with a 2-year manufacturer warranty. Schneider publishes a single worldwide figure of “2 years repair or replace” for the Easy UPS On-Line SRV range — there is no separate European and rest-of-world split on this family, so the term above is the one that applies in Singapore.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bzQk-YuLvCM\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039262834852,"sku":"SRV1KRI + SRVRK1","price":625.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri-939358.jpg?v=1671696950"},{"product_id":"apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri","title":"APC Easy UPS On-Line SRV 2000VA RM 230V with Rail Kit","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRV 2000VA RM 230V with Rail Kit (SRV2KRI) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDouble-Conversion On-Line Protection for Singapore's 230 V \/ 50 Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC SRV2KRI is a \u003cstrong\u003edouble-conversion on-line UPS\u003c\/strong\u003e: incoming mains is rectified to DC and rebuilt as a clean sine wave output, so the connected load never sees the supply it is actually plugged into. That matters on the Singapore grid, where the day-to-day problem is rarely a full blackout and much more often the voltage sag that arrives with an afternoon thunderstorm, or the disturbance from a large motor load elsewhere in the building. The unit rides those out on its inverter, holding a 160–280 V full-load input window before it needs the battery at all.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e2000 VA of Protected Capacity, 1600 W of Real Power\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRated at \u003cstrong\u003e2000 VA \/ 1600 W\u003c\/strong\u003e, the SRV2KRI is sized for a comms cabinet, a pair of servers or a PoE switch stack. Size against the watts figure rather than the VA figure — servers, switches and storage are watts loads — and leave headroom rather than running it hard, which costs you both runtime and battery life. On-line efficiency is 88 % at full load, and output distortion is held to 3 %, which is what an active-PFC server power supply expects to see.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e2U Rackmount with SRVRK1 Rail Kit for Your Comms Cabinet\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis build occupies \u003cstrong\u003e2U\u003c\/strong\u003e and measures 86 mm (H) × 437 mm (W) × 462 mm (D), with a chassis depth of \u003cstrong\u003e462 mm\u003c\/strong\u003e — the number to check against your cabinet before you order. Schneider sells the bare UPS as a “W\/O rail kit” part number; this SourceIT bundle adds the \u003cstrong\u003eSRVRK1\u003c\/strong\u003e 19-inch rail kit, rated to 60 kg, as a separate carton, and the UPS carton itself contains rack mounting brackets. Output is 4 × IEC 60320 C13 (all battery backup and surge protected).\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBatteries, Service Life and Singapore's Heat\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInternal batteries are maintenance-free sealed VRLA (48 V DC, 305 VAh), recharging in 4 hours, with an expected service life of 3–5 years. Heat is what actually kills UPS batteries, and a poorly ventilated cabinet in Singapore's climate will take years off them — the unit is rated for 0 °C to 40 °C and runs at 50 dBA, so give it airflow. When the time comes the cartridge is \u003cstrong\u003eAPCRBCV201 (VRLA, 9 Ah, 48 V DC)\u003c\/strong\u003e and it is user-replaceable, with battery condition readable from the front-panel LCD.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBuy the APC SRV2KRI in Singapore with Local Warranty and GST Invoice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the APC SRV2KRI from Singapore with a GST invoice and local warranty support, backed by APC's 2-year manufacturer warranty. Tell us the load you need to protect — in watts, and how long you need it to stay up — and we will size the unit, the cartridge and the network card properly rather than sell you the nearest number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRV2KRI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRV2KRI + SRVRK1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSRV2KRI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \/ Series\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric — Easy UPS On-Line SRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider product name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line, 2000VA\/1600W, Rackmount 2U, 230V, 4x IEC C13 outlets, Intelligent Card Slot, LCD, W\/O rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eRackmount, 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack height\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal, configurable for 220 \/ 230 \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz ± 3 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage distortion\u003c\/td\u003e\n\u003ctd\u003e3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3 : 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-line efficiency\u003c\/td\u003e\n\u003ctd\u003e88 % at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput connections\u003c\/td\u003e\n\u003ctd\u003e4 × IEC 60320 C13 (all battery backup and surge protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e600 Joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range\u003c\/td\u003e\n\u003ctd\u003e160–280 V at full load; 110–285 V at half load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet, 1.5 m input cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed valve-regulated lead-acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e48 V DC, 305 VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement battery cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBCV201 (VRLA, 9 Ah, 48 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical recharge time\u003c\/td\u003e\n\u003ctd\u003e4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected battery life\u003c\/td\u003e\n\u003ctd\u003e3–5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal battery pack\u003c\/td\u003e\n\u003ctd\u003eNot supported on this model — internal batteries only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging power\u003c\/td\u003e\n\u003ctd\u003e70 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eYes (USB cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial port\u003c\/td\u003e\n\u003ctd\u003eRS-232, DB-9 (configuration cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard slot\u003c\/td\u003e\n\u003ctd\u003e1 × Intelligent Card Slot (Schneider’s term — not a Smart-UPS “SmartSlot”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork management card\u003c\/td\u003e\n\u003ctd\u003eAPV9601 — APC Easy UPS On-Line SRV SNMP card (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutdown software\u003c\/td\u003e\n\u003ctd\u003eCompatible with PowerChute Serial Shutdown and PowerChute Business Edition — Schneider FAQ FA315835 lists SRV models of 3 kVA and below as supported over USB or serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eNot available on this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm\u003c\/td\u003e\n\u003ctd\u003eOn battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86 mm (H) × 437 mm (W) × 462 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e18.2 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity\u003c\/td\u003e\n\u003ctd\u003e0–95 % relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating elevation\u003c\/td\u003e\n\u003ctd\u003e0–3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible noise\u003c\/td\u003e\n\u003ctd\u003e50 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal dissipation\u003c\/td\u003e\n\u003ctd\u003e745 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications and standards\u003c\/td\u003e\n\u003ctd\u003eCE, EAC, TISI; EN\/IEC 62040-1, EN\/IEC 62040-2; RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eSRVRK1 Rail Kit (supplied with this bundle)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRVRK1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV 19-inch rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS Rackmount SRV and SRVL models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum equipment weight\u003c\/td\u003e\n\u003ctd\u003e60 kg (132 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported equipment width\u003c\/td\u003e\n\u003ctd\u003e43–45 cm (16.75–17.7 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider publishes two contradictory cabinet-depth figures for the SRVRK1 across its own regional catalogues (700 mm on some, 780 mm on others), so no depth rating is quoted here. The figure that actually governs your install is the UPS chassis depth of 462 mm, given above.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe SRV2KRI provides \u003cstrong\u003e4 × IEC 60320 C13 (all battery backup and surge protected)\u003c\/strong\u003e. Every outlet is fed from the inverter, so all of them carry battery backup and surge protection — there is no surge-only bank on this model. Rated capacity is 2000 VA \/ 1600 W: size the load against the \u003cstrong\u003e1600 W figure\u003c\/strong\u003e, because a server, switch or storage array is a watts load, not a VA load.\u003c\/p\u003e\n\u003ch4\u003eInput and circuit requirements\u003c\/h4\u003e\n\u003cp\u003eInput connection is \u003cstrong\u003eIEC 60320 C14 inlet, 1.5 m input cord\u003c\/strong\u003e. Singapore mains is 230 V \/ 50 Hz, which sits comfortably inside this unit's 160–280 V full-load input window, and the on-line inverter regenerates the output waveform continuously rather than switching to battery for every dip — useful during the voltage sags that accompany a thunderstorm on the PUB grid.\u003c\/p\u003e\n\u003ch4\u003eRack space and depth\u003c\/h4\u003e\n\u003cp\u003eThis is a \u003cstrong\u003e2U rackmount\u003c\/strong\u003e unit, 86 mm (H) × 437 mm (W) × 462 mm (D), and it is rack-only — there is no tower conversion. The number that decides whether it fits your cabinet is the chassis depth of \u003cstrong\u003e462 mm\u003c\/strong\u003e. At 462 mm it suits a standard comms cabinet comfortably.\u003c\/p\u003e\n\u003cp\u003eSchneider's own part number for this UPS ends in “W\/O rail kit” — the bare SRV2KRI does not include rails. This SourceIT listing is the bundle: the UPS plus a separate \u003cstrong\u003eSRVRK1\u003c\/strong\u003e 19-inch rail kit carton, rated to 60 kg. The UPS carton itself also contains rack mounting brackets.\u003c\/p\u003e\n\u003ch4\u003eBatteries and runtime\u003c\/h4\u003e\n\u003cp\u003eThe SRV2KRI runs on sealed maintenance-free VRLA batteries at 48 V DC, 305 VAh, and recharges in 4 hours. Expected service life is 3–5 years in a temperature-controlled room; Singapore's ambient heat and humidity are the main things that shorten it, so a comms cabinet with airflow is worth the effort.\u003c\/p\u003e\n\u003cp\u003eSchneider publishes no runtime-at-load table for this model that we could verify against two independent sources, so none is quoted here. Send us your load in watts and the autonomy you need — \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e — and we will size it properly rather than guess.\u003c\/p\u003e\n\u003cp\u003eThe matching replacement battery cartridge is \u003cstrong\u003eAPCRBCV201 (VRLA, 9 Ah, 48 V DC)\u003c\/strong\u003e. Note this is the APCRBCV series used by Easy UPS On-Line, which is a different range from the APCRBC cartridges used by Smart-UPS — do not substitute across the two.\u003c\/p\u003e\n\u003cp\u003eThis model does \u003cstrong\u003enot\u003c\/strong\u003e accept an external battery pack. If you need longer autonomy at this capacity, the extended-runtime power-module models are the correct product — they are listed in the ordering block below.\u003c\/p\u003e\n\u003ch4\u003eManagement options\u003c\/h4\u003e\n\u003cp\u003eThe SRV2KRI has a USB port, an RS-232 DB-9 serial port and one \u003cstrong\u003eIntelligent Card Slot\u003c\/strong\u003e. Schneider's card for that slot is the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e. The Easy UPS On-Line SRV range uses a different card family from Smart-UPS: the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will \u003cstrong\u003enot\u003c\/strong\u003e work in this UPS.\u003c\/p\u003e\n\u003cp\u003eFor direct USB or serial shutdown of a single host, Schneider's FAQ FA315835 lists SRV models of 3 kVA and below as supported by PowerChute Serial Shutdown and PowerChute Business Edition. PowerChute itself is a Schneider download rather than a licence sold with the UPS — ask us if you want the current version confirmed for your operating system before you commission.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 × RS-232 signalling cable\u003c\/li\u003e\n\u003cli\u003e1 × USB cable\u003c\/li\u003e\n\u003cli\u003e1 × CD with software\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003cli\u003eRack mounting brackets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — tower models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-230v-srv1ki\"\u003eAPC Easy UPS On-Line SRV1KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-srv2ki\"\u003eAPC Easy UPS On-Line SRV2KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-srv3ki\"\u003eAPC Easy UPS On-Line SRV3KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — rackmount 2U models (supplied with SRVRK1 rail kit)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri\"\u003eAPC Easy UPS On-Line SRV1KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRV2KRI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri\"\u003eAPC Easy UPS On-Line SRV3KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eExtended-runtime models (no internal battery, external pack supplied)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery pack\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-external-battery-pack-srv3kri\"\u003eAPC Easy UPS On-Line SRVPM1KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · SRV36BP-9A (36 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-with-extended-runtime-battery-pack-srv2kil\"\u003eAPC Easy UPS On-Line SRVPM2KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-with-extended-runtime-battery-pack-srv3kil\"\u003eAPC Easy UPS On-Line SRVPM3KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eLarger Easy UPS On-Line SRV models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity and format\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-6000va-230v-srv6ki\"\u003eAPC Easy UPS On-Line SRV6KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-10000va-230v-srv10ki\"\u003eAPC Easy UPS On-Line SRV10KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-6000va-230v-with-railkit-external-battery-pack-srv6krirk\"\u003eAPC Easy UPS On-Line SRV6KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-railkit-external-battery-pack-srv10krirk\"\u003eAPC Easy UPS On-Line SRV10KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eAccessories for this UPS\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWhat it is\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPC Easy UPS On-Line SRV SNMP Card (APV9601)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSNMP network management card for the Intelligent Card Slot. The correct card for Easy UPS On-Line SRV — the Smart-UPS AP9640 and AP9641 cards do not fit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPCRBCV201 (VRLA, 9 Ah, 48 V DC)\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for this model. User-replaceable. Order by this exact part number — the APCRBCV series is specific to Easy UPS On-Line and is not interchangeable with Smart-UPS APCRBC cartridges. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e to order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVRK1\u003c\/td\u003e\n\u003ctd\u003e19-inch rail kit, rated to 60 kg. Already included in this bundle as a separate carton.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCurrent-generation alternative\u003c\/h4\u003e\n\u003cp\u003eSchneider has moved this range to the “-E” generation, which is a genuinely different build — higher output wattage at the same VA rating (0.9 output power factor instead of 0.8), EPO support and different battery cartridges. If you are specifying a new installation rather than matching existing equipment, look at \u003ca href=\"\/products\/apc-easy-ups-on-line-srv-rm-2000va-1800w-230v-with-rail-kit-srv2krirk-e\"\u003eAPC Easy UPS SRV 2000VA 1800W 230V with Rail Kit (SRV2KRIRK-E)\u003c\/a\u003e. Do not assume the two share specifications.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/au\/en\/product\/SRV2KRI\/apc-easy-ups-online-2000va-1600w-rackmount-2u-230v-4x-iec-c13-outlets-intelligent-card-slot-lcd-w-o-rail-kit\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Schneider Electric product page for the APC SRV2KRI\u003c\/a\u003e — Australia (no Singapore page is published for this part number) regional page. Schneider publishes the product datasheet, user guide and environmental disclosure from the document list on that page.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/SRVRK1\/apc-easy-ups-online-srv-19-rail-kit-780mm-depth\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Schneider Electric product page for the SRVRK1 rail kit\u003c\/a\u003e supplied with this bundle.\u003c\/p\u003e\n\u003cp\u003eSchneider serves its APC datasheet PDFs from a redirecting download host that regularly returns the wrong model's document, so we do not publish direct PDF links that we cannot verify resolve to the right part number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with the model you need and we will send the correct current-revision datasheet and user manual, along with a GST-invoiced quotation.\u003c\/p\u003e\n\u003cp\u003eEvery specification on this page was taken from Schneider Electric's own product page and its published product datasheet or user manual for this exact part number. Where Schneider's own sources disagreed, or published nothing, the field has been left out rather than estimated.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRV2KRI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 2000 VA and 1600 W ratings, and how do I size it?\u003c\/h4\u003e\n\u003cp\u003eVA is apparent power, watts is real power. The SRV2KRI is rated 2000 VA \/ 1600 W, an output power factor of 0.8. Add up the watts of everything you intend to protect, keep the total under 1600 W, and leave headroom — loading a UPS to 100 % shortens both runtime and battery life. As a rough Singapore rule of thumb, a 1U rack server draws 200–400 W, a 24-port PoE switch 150–400 W depending on how much PoE is actually drawn, and a small NAS 60–120 W. Send us the list and we will size it.\u003c\/p\u003e\n\u003ch4\u003eHow long will the SRV2KRI run my equipment?\u003c\/h4\u003e\n\u003cp\u003eSchneider does not publish a runtime-at-load table for this model that we could verify against two independent official sources, so we do not quote minutes here rather than invent them.\u003c\/p\u003e\n\u003cp\u003eWhat matters in practice is that an on-line UPS in this class is sized for a clean shutdown or a generator start, not for riding through a long outage. If you need tens of minutes, the extended-runtime power-module models with external battery packs are the right product. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with your load in watts and the autonomy you want.\u003c\/p\u003e\n\u003ch4\u003eIs the output a true sine wave, and will it work with an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eYes. Schneider's datasheet for this exact model states a \u003cstrong\u003esine wave\u003c\/strong\u003e output with 3 % voltage distortion, and the topology is \u003cstrong\u003edouble conversion on-line\u003c\/strong\u003e — the load is fed from the inverter continuously rather than being switched over when mains fails. That is what an active-PFC server or workstation PSU wants; the step-approximated output of a low-cost standby UPS is what causes those supplies to trip. Schneider does not publish a numeric transfer time for this model and we do not claim one.\u003c\/p\u003e\n\u003ch4\u003eWhat do the different Easy UPS On-Line suffixes mean?\u003c\/h4\u003e\n\u003cp\u003eThey are genuinely different builds, not marketing variants. \u003cstrong\u003eKI\u003c\/strong\u003e is a tower with internal batteries. \u003cstrong\u003eKRI\u003c\/strong\u003e is the 2U rackmount build of the same capacity — different outlet count and dimensions, so do not read tower specs onto a rack unit. \u003cstrong\u003ePM…IL\u003c\/strong\u003e is an extended-runtime power module with no internal batteries, supplied with an external pack. \u003cstrong\u003e-E\u003c\/strong\u003e is the newer generation with a 0.9 output power factor, so an SRV3KI-E delivers 2700 W where this generation delivers 2400 W at the same 3 kVA. \u003cstrong\u003eRK\u003c\/strong\u003e means the rail kit is included in the part number.\u003c\/p\u003e\n\u003ch4\u003eWhich replacement battery cartridge does the SRV2KRI take, and can I change it myself?\u003c\/h4\u003e\n\u003cp\u003eThe cartridge is \u003cstrong\u003eAPCRBCV201 (VRLA, 9 Ah, 48 V DC)\u003c\/strong\u003e. It is user-replaceable, and the batteries are the consumable part of any UPS — expect 3–5 years in a well-ventilated room, less in a hot cabinet, which is the usual Singapore constraint. Order by that exact part number: the \u003cstrong\u003eAPCRBCV\u003c\/strong\u003e series belongs to Easy UPS On-Line and is \u003cem\u003enot\u003c\/em\u003e interchangeable with the \u003cstrong\u003eAPCRBC\u003c\/strong\u003e cartridges used by Smart-UPS, even where the voltage looks similar. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e to order one.\u003c\/p\u003e\n\u003ch4\u003eHow much rack space does it need, and are the rails included?\u003c\/h4\u003e\n\u003cp\u003eIt occupies \u003cstrong\u003e2U\u003c\/strong\u003e and the chassis is \u003cstrong\u003e462 mm deep\u003c\/strong\u003e. Schneider's part number for the bare UPS ends in “W\/O rail kit”, so the rails are a separate item — and they are included in this SourceIT bundle as an \u003cstrong\u003eSRVRK1\u003c\/strong\u003e carton alongside the UPS. The UPS carton also contains rack mounting brackets. The rail kit is rated to 60 kg, comfortably above this unit's net weight of 18.2 kg. At 462 mm it fits a standard comms cabinet.\u003c\/p\u003e\n\u003ch4\u003eHow do I monitor it over the network?\u003c\/h4\u003e\n\u003cp\u003eFit the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e in the UPS Intelligent Card Slot. That is the Easy UPS On-Line card — the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will not work here. Without a card you still get USB and RS-232 for a direct shutdown link to one host, with PowerChute Serial Shutdown or PowerChute Business Edition. Note that Schneider has discontinued the APV9601; ask us about current stock and the AP9544 successor before you commit to a monitoring design.\u003c\/p\u003e\n\u003ch4\u003eIs the SRV2KRI covered by warranty in Singapore?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC SRV2KRI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRV2KRI with a 2-year manufacturer warranty. Schneider publishes a single worldwide figure of “2 years repair or replace” for the Easy UPS On-Line SRV range — there is no separate European and rest-of-world split on this family, so the term above is the one that applies in Singapore.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bzQk-YuLvCM\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039281479844,"sku":"SRV2KRI + SRVRK1","price":1165.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri-879471.jpg?v=1702980113"},{"product_id":"apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri","title":"APC Easy UPS On-Line SRV 3000VA RM 230V with Rail Kit","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRV 3000VA RM 230V with Rail Kit (SRV3KRI) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDouble-Conversion On-Line Protection for Singapore's 230 V \/ 50 Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC SRV3KRI is a \u003cstrong\u003edouble-conversion on-line UPS\u003c\/strong\u003e: incoming mains is rectified to DC and rebuilt as a clean sine wave output, so the connected load never sees the supply it is actually plugged into. That matters on the Singapore grid, where the day-to-day problem is rarely a full blackout and much more often the voltage sag that arrives with an afternoon thunderstorm, or the disturbance from a large motor load elsewhere in the building. The unit rides those out on its inverter, holding a 160–280 V full-load input window before it needs the battery at all.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e3000 VA of Protected Capacity, 2400 W of Real Power\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRated at \u003cstrong\u003e3000 VA \/ 2400 W\u003c\/strong\u003e, the SRV3KRI is sized for a loaded comms cabinet, a small server room or a rack of network and storage equipment. Size against the watts figure rather than the VA figure — servers, switches and storage are watts loads — and leave headroom rather than running it hard, which costs you both runtime and battery life. On-line efficiency is 88 % at full load, and output distortion is held to 3 %, which is what an active-PFC server power supply expects to see.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e2U Rackmount with SRVRK1 Rail Kit for Your Comms Cabinet\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis build occupies \u003cstrong\u003e2U\u003c\/strong\u003e and measures 86 mm (H) × 437 mm (W) × 632 mm (D), with a chassis depth of \u003cstrong\u003e632 mm\u003c\/strong\u003e — the number to check against your cabinet before you order. Schneider sells the bare UPS as a “W\/O rail kit” part number; this SourceIT bundle adds the \u003cstrong\u003eSRVRK1\u003c\/strong\u003e 19-inch rail kit, rated to 60 kg, as a separate carton, and the UPS carton itself contains rack mounting brackets. Output is 6 × IEC 60320 C13 + 1 × IEC 60320 C19 (all battery backup and surge protected).\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBatteries, Service Life and Singapore's Heat\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInternal batteries are maintenance-free sealed VRLA (72 V DC), recharging in 4 hours, with an expected service life of 3–5 years. Heat is what actually kills UPS batteries, and a poorly ventilated cabinet in Singapore's climate will take years off them — the unit is rated for 0 °C to 40 °C and runs at 50 dBA, so give it airflow. When the time comes the cartridge is \u003cstrong\u003eAPCRBCV202 (VRLA, 9 Ah, 72 V DC)\u003c\/strong\u003e and it is user-replaceable, with battery condition readable from the front-panel LCD.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBuy the APC SRV3KRI in Singapore with Local Warranty and GST Invoice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the APC SRV3KRI from Singapore with a GST invoice and local warranty support, backed by APC's 2-year manufacturer warranty. Tell us the load you need to protect — in watts, and how long you need it to stay up — and we will size the unit, the cartridge and the network card properly rather than sell you the nearest number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRV3KRI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRV3KRI + SRVRK1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSRV3KRI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \/ Series\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric — Easy UPS On-Line SRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider product name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line, 3kVA\/2400W, Rackmount 2U, 230V, 6x IEC C13 + 1x IEC C19 outlets, Intelligent Card Slot, LCD, W\/O rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eRackmount, 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack height\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal, configurable for 220 \/ 230 \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz ± 3 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage distortion\u003c\/td\u003e\n\u003ctd\u003e3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3 : 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-line efficiency\u003c\/td\u003e\n\u003ctd\u003e88 % at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput connections\u003c\/td\u003e\n\u003ctd\u003e6 × IEC 60320 C13 + 1 × IEC 60320 C19 (all battery backup and surge protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e600 Joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range\u003c\/td\u003e\n\u003ctd\u003e160–280 V at full load; 110–285 V at half load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C20 inlet, 1.48 m input cord — a 16 A inlet, not the 10 A C14 used on the 1 kVA and 2 kVA models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed valve-regulated lead-acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e72 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement battery cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBCV202 (VRLA, 9 Ah, 72 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical recharge time\u003c\/td\u003e\n\u003ctd\u003e4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected battery life\u003c\/td\u003e\n\u003ctd\u003e3–5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal battery pack\u003c\/td\u003e\n\u003ctd\u003eNot supported on this model — internal batteries only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging power\u003c\/td\u003e\n\u003ctd\u003e60 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eYes (USB cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial port\u003c\/td\u003e\n\u003ctd\u003eRS-232, DB-9 (configuration cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard slot\u003c\/td\u003e\n\u003ctd\u003e1 × Intelligent Card Slot (Schneider’s term — not a Smart-UPS “SmartSlot”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork management card\u003c\/td\u003e\n\u003ctd\u003eAPV9601 — APC Easy UPS On-Line SRV SNMP card (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutdown software\u003c\/td\u003e\n\u003ctd\u003eCompatible with PowerChute Serial Shutdown and PowerChute Business Edition — Schneider FAQ FA315835 lists SRV models of 3 kVA and below as supported over USB or serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eNot available on this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm\u003c\/td\u003e\n\u003ctd\u003eOn battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86 mm (H) × 437 mm (W) × 632 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e27.6 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity\u003c\/td\u003e\n\u003ctd\u003e0–95 % relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating elevation\u003c\/td\u003e\n\u003ctd\u003e0–3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible noise\u003c\/td\u003e\n\u003ctd\u003e50 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications and standards\u003c\/td\u003e\n\u003ctd\u003eCE, EAC, TISI; EN\/IEC 62040-1, EN\/IEC 62040-2; RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eSRVRK1 Rail Kit (supplied with this bundle)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRVRK1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV 19-inch rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS Rackmount SRV and SRVL models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum equipment weight\u003c\/td\u003e\n\u003ctd\u003e60 kg (132 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported equipment width\u003c\/td\u003e\n\u003ctd\u003e43–45 cm (16.75–17.7 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider publishes two contradictory cabinet-depth figures for the SRVRK1 across its own regional catalogues (700 mm on some, 780 mm on others), so no depth rating is quoted here. The figure that actually governs your install is the UPS chassis depth of 632 mm, given above.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe SRV3KRI provides \u003cstrong\u003e6 × IEC 60320 C13 + 1 × IEC 60320 C19 (all battery backup and surge protected)\u003c\/strong\u003e. Every outlet is fed from the inverter, so all of them carry battery backup and surge protection — there is no surge-only bank on this model. Rated capacity is 3000 VA \/ 2400 W: size the load against the \u003cstrong\u003e2400 W figure\u003c\/strong\u003e, because a server, switch or storage array is a watts load, not a VA load.\u003c\/p\u003e\n\u003cp\u003eThe single IEC C19 outlet is the one to reserve for a higher-draw device — a blade chassis, a large PSU or a rack PDU feeding a sub-bank. Note this model has \u003cstrong\u003eone\u003c\/strong\u003e C19, not two.\u003c\/p\u003e\n\u003ch4\u003eInput and circuit requirements\u003c\/h4\u003e\n\u003cp\u003eInput connection is \u003cstrong\u003eIEC 60320 C20 inlet, 1.48 m input cord — a 16 A inlet, not the 10 A C14 used on the 1 kVA and 2 kVA models\u003c\/strong\u003e. Singapore mains is 230 V \/ 50 Hz, which sits comfortably inside this unit's 160–280 V full-load input window, and the on-line inverter regenerates the output waveform continuously rather than switching to battery for every dip — useful during the voltage sags that accompany a thunderstorm on the PUB grid.\u003c\/p\u003e\n\u003ch4\u003eRack space and depth\u003c\/h4\u003e\n\u003cp\u003eThis is a \u003cstrong\u003e2U rackmount\u003c\/strong\u003e unit, 86 mm (H) × 437 mm (W) × 632 mm (D), and it is rack-only — there is no tower conversion. The number that decides whether it fits your cabinet is the chassis depth of \u003cstrong\u003e632 mm\u003c\/strong\u003e. At 632 mm this unit will \u003cstrong\u003enot\u003c\/strong\u003e fit a shallow 600 mm comms cabinet; plan on an 800 mm or deeper rack.\u003c\/p\u003e\n\u003cp\u003eSchneider's own part number for this UPS ends in “W\/O rail kit” — the bare SRV3KRI does not include rails. This SourceIT listing is the bundle: the UPS plus a separate \u003cstrong\u003eSRVRK1\u003c\/strong\u003e 19-inch rail kit carton, rated to 60 kg. The UPS carton itself also contains rack mounting brackets.\u003c\/p\u003e\n\u003ch4\u003eBatteries and runtime\u003c\/h4\u003e\n\u003cp\u003eThe SRV3KRI runs on sealed maintenance-free VRLA batteries at 72 V DC, and recharges in 4 hours. Expected service life is 3–5 years in a temperature-controlled room; Singapore's ambient heat and humidity are the main things that shorten it, so a comms cabinet with airflow is worth the effort.\u003c\/p\u003e\n\u003cp\u003eSchneider publishes no runtime-at-load table for this model that we could verify against two independent sources, so none is quoted here. Send us your load in watts and the autonomy you need — \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e — and we will size it properly rather than guess.\u003c\/p\u003e\n\u003cp\u003eThe matching replacement battery cartridge is \u003cstrong\u003eAPCRBCV202 (VRLA, 9 Ah, 72 V DC)\u003c\/strong\u003e. Note this is the APCRBCV series used by Easy UPS On-Line, which is a different range from the APCRBC cartridges used by Smart-UPS — do not substitute across the two.\u003c\/p\u003e\n\u003cp\u003eThis model does \u003cstrong\u003enot\u003c\/strong\u003e accept an external battery pack. If you need longer autonomy at this capacity, the extended-runtime power-module models are the correct product — they are listed in the ordering block below.\u003c\/p\u003e\n\u003ch4\u003eManagement options\u003c\/h4\u003e\n\u003cp\u003eThe SRV3KRI has a USB port, an RS-232 DB-9 serial port and one \u003cstrong\u003eIntelligent Card Slot\u003c\/strong\u003e. Schneider's card for that slot is the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e. The Easy UPS On-Line SRV range uses a different card family from Smart-UPS: the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will \u003cstrong\u003enot\u003c\/strong\u003e work in this UPS.\u003c\/p\u003e\n\u003cp\u003eFor direct USB or serial shutdown of a single host, Schneider's FAQ FA315835 lists SRV models of 3 kVA and below as supported by PowerChute Serial Shutdown and PowerChute Business Edition. PowerChute itself is a Schneider download rather than a licence sold with the UPS — ask us if you want the current version confirmed for your operating system before you commission.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 × IEC C20 to Schuko input power cord\u003c\/li\u003e\n\u003cli\u003e1 × IEC C13 to C14 power cord\u003c\/li\u003e\n\u003cli\u003e1 × RS-232 signalling cable\u003c\/li\u003e\n\u003cli\u003e1 × USB cable\u003c\/li\u003e\n\u003cli\u003e1 × CD with software\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003cli\u003eRack mounting brackets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — tower models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-230v-srv1ki\"\u003eAPC Easy UPS On-Line SRV1KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-srv2ki\"\u003eAPC Easy UPS On-Line SRV2KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-srv3ki\"\u003eAPC Easy UPS On-Line SRV3KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — rackmount 2U models (supplied with SRVRK1 rail kit)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri\"\u003eAPC Easy UPS On-Line SRV1KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri\"\u003eAPC Easy UPS On-Line SRV2KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRV3KRI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eExtended-runtime models (no internal battery, external pack supplied)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery pack\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-external-battery-pack-srv3kri\"\u003eAPC Easy UPS On-Line SRVPM1KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · SRV36BP-9A (36 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-with-extended-runtime-battery-pack-srv2kil\"\u003eAPC Easy UPS On-Line SRVPM2KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-with-extended-runtime-battery-pack-srv3kil\"\u003eAPC Easy UPS On-Line SRVPM3KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eLarger Easy UPS On-Line SRV models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity and format\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-6000va-230v-srv6ki\"\u003eAPC Easy UPS On-Line SRV6KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-10000va-230v-srv10ki\"\u003eAPC Easy UPS On-Line SRV10KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-6000va-230v-with-railkit-external-battery-pack-srv6krirk\"\u003eAPC Easy UPS On-Line SRV6KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-railkit-external-battery-pack-srv10krirk\"\u003eAPC Easy UPS On-Line SRV10KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eAccessories for this UPS\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWhat it is\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPC Easy UPS On-Line SRV SNMP Card (APV9601)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSNMP network management card for the Intelligent Card Slot. The correct card for Easy UPS On-Line SRV — the Smart-UPS AP9640 and AP9641 cards do not fit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPCRBCV202 (VRLA, 9 Ah, 72 V DC)\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for this model. User-replaceable. Order by this exact part number — the APCRBCV series is specific to Easy UPS On-Line and is not interchangeable with Smart-UPS APCRBC cartridges. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e to order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVRK1\u003c\/td\u003e\n\u003ctd\u003e19-inch rail kit, rated to 60 kg. Already included in this bundle as a separate carton.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCurrent-generation alternative\u003c\/h4\u003e\n\u003cp\u003eSchneider has moved this range to the “-E” generation, which is a genuinely different build — higher output wattage at the same VA rating (0.9 output power factor instead of 0.8), EPO support and different battery cartridges. If you are specifying a new installation rather than matching existing equipment, look at \u003ca href=\"\/products\/apc-easy-ups-on-line-srv-rm-3000va-2700w-230v-with-rail-kit-srv3krirk-e\"\u003eAPC Easy UPS SRV 3000VA 2700W 230V with Rail Kit (SRV3KRIRK-E)\u003c\/a\u003e. Do not assume the two share specifications.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/SRV3KRI\/apc-easy-ups-online-srv-3000va-rm-230v\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Schneider Electric product page for the APC SRV3KRI\u003c\/a\u003e — Singapore regional page. Schneider publishes the product datasheet, user guide and environmental disclosure from the document list on that page.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/SRVRK1\/apc-easy-ups-online-srv-19-rail-kit-780mm-depth\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Schneider Electric product page for the SRVRK1 rail kit\u003c\/a\u003e supplied with this bundle.\u003c\/p\u003e\n\u003cp\u003eSchneider serves its APC datasheet PDFs from a redirecting download host that regularly returns the wrong model's document, so we do not publish direct PDF links that we cannot verify resolve to the right part number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with the model you need and we will send the correct current-revision datasheet and user manual, along with a GST-invoiced quotation.\u003c\/p\u003e\n\u003cp\u003eEvery specification on this page was taken from Schneider Electric's own product page and its published product datasheet or user manual for this exact part number. Where Schneider's own sources disagreed, or published nothing, the field has been left out rather than estimated.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRV3KRI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 3000 VA and 2400 W ratings, and how do I size it?\u003c\/h4\u003e\n\u003cp\u003eVA is apparent power, watts is real power. The SRV3KRI is rated 3000 VA \/ 2400 W, an output power factor of 0.8. Add up the watts of everything you intend to protect, keep the total under 2400 W, and leave headroom — loading a UPS to 100 % shortens both runtime and battery life. As a rough Singapore rule of thumb, a 1U rack server draws 200–400 W, a 24-port PoE switch 150–400 W depending on how much PoE is actually drawn, and a small NAS 60–120 W. Send us the list and we will size it.\u003c\/p\u003e\n\u003ch4\u003eHow long will the SRV3KRI run my equipment?\u003c\/h4\u003e\n\u003cp\u003eSchneider does not publish a runtime-at-load table for this model that we could verify against two independent official sources, so we do not quote minutes here rather than invent them.\u003c\/p\u003e\n\u003cp\u003eWhat matters in practice is that an on-line UPS in this class is sized for a clean shutdown or a generator start, not for riding through a long outage. If you need tens of minutes, the extended-runtime power-module models with external battery packs are the right product. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with your load in watts and the autonomy you want.\u003c\/p\u003e\n\u003ch4\u003eIs the output a true sine wave, and will it work with an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eYes. Schneider's datasheet for this exact model states a \u003cstrong\u003esine wave\u003c\/strong\u003e output with 3 % voltage distortion, and the topology is \u003cstrong\u003edouble conversion on-line\u003c\/strong\u003e — the load is fed from the inverter continuously rather than being switched over when mains fails. That is what an active-PFC server or workstation PSU wants; the step-approximated output of a low-cost standby UPS is what causes those supplies to trip. Schneider does not publish a numeric transfer time for this model and we do not claim one.\u003c\/p\u003e\n\u003ch4\u003eWhat do the different Easy UPS On-Line suffixes mean?\u003c\/h4\u003e\n\u003cp\u003eThey are genuinely different builds, not marketing variants. \u003cstrong\u003eKI\u003c\/strong\u003e is a tower with internal batteries. \u003cstrong\u003eKRI\u003c\/strong\u003e is the 2U rackmount build of the same capacity — different outlet count and dimensions, so do not read tower specs onto a rack unit. \u003cstrong\u003ePM…IL\u003c\/strong\u003e is an extended-runtime power module with no internal batteries, supplied with an external pack. \u003cstrong\u003e-E\u003c\/strong\u003e is the newer generation with a 0.9 output power factor, so an SRV3KI-E delivers 2700 W where this generation delivers 2400 W at the same 3 kVA. \u003cstrong\u003eRK\u003c\/strong\u003e means the rail kit is included in the part number.\u003c\/p\u003e\n\u003ch4\u003eWhich replacement battery cartridge does the SRV3KRI take, and can I change it myself?\u003c\/h4\u003e\n\u003cp\u003eThe cartridge is \u003cstrong\u003eAPCRBCV202 (VRLA, 9 Ah, 72 V DC)\u003c\/strong\u003e. It is user-replaceable, and the batteries are the consumable part of any UPS — expect 3–5 years in a well-ventilated room, less in a hot cabinet, which is the usual Singapore constraint. Order by that exact part number: the \u003cstrong\u003eAPCRBCV\u003c\/strong\u003e series belongs to Easy UPS On-Line and is \u003cem\u003enot\u003c\/em\u003e interchangeable with the \u003cstrong\u003eAPCRBC\u003c\/strong\u003e cartridges used by Smart-UPS, even where the voltage looks similar. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e to order one.\u003c\/p\u003e\n\u003ch4\u003eHow much rack space does it need, and are the rails included?\u003c\/h4\u003e\n\u003cp\u003eIt occupies \u003cstrong\u003e2U\u003c\/strong\u003e and the chassis is \u003cstrong\u003e632 mm deep\u003c\/strong\u003e. Schneider's part number for the bare UPS ends in “W\/O rail kit”, so the rails are a separate item — and they are included in this SourceIT bundle as an \u003cstrong\u003eSRVRK1\u003c\/strong\u003e carton alongside the UPS. The UPS carton also contains rack mounting brackets. The rail kit is rated to 60 kg, comfortably above this unit's net weight of 27.6 kg. At 632 mm deep, check your cabinet before ordering — this will not fit a 600 mm comms cabinet.\u003c\/p\u003e\n\u003ch4\u003eHow do I monitor it over the network?\u003c\/h4\u003e\n\u003cp\u003eFit the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e in the UPS Intelligent Card Slot. That is the Easy UPS On-Line card — the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will not work here. Without a card you still get USB and RS-232 for a direct shutdown link to one host, with PowerChute Serial Shutdown or PowerChute Business Edition. Note that Schneider has discontinued the APV9601; ask us about current stock and the AP9544 successor before you commit to a monitoring design.\u003c\/p\u003e\n\u003ch4\u003eIs the SRV3KRI covered by warranty in Singapore?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC SRV3KRI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRV3KRI with a 2-year manufacturer warranty. Schneider publishes a single worldwide figure of “2 years repair or replace” for the Easy UPS On-Line SRV range — there is no separate European and rest-of-world split on this family, so the term above is the one that applies in Singapore.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bzQk-YuLvCM\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039309922468,"sku":"SRV3KRI + SRVRK1","price":1565.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri-837106.jpg?v=1702980107"},{"product_id":"apc-easy-ups-on-line-srv-3000va-rm-230v-with-external-battery-pack-srv3kri","title":"APC Easy UPS On-Line 1000VA, Ext. Runtime","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Easy UPS On-Line 1000VA, Ext. Runtime (SRVPM1KIL) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDouble-Conversion On-Line Protection for Singapore's 230 V \/ 50 Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC SRVPM1KIL is a \u003cstrong\u003edouble-conversion on-line UPS\u003c\/strong\u003e: incoming mains is rectified to DC and rebuilt as a clean sine wave output, so the connected load never sees the supply it is actually plugged into. That matters on the Singapore grid, where the day-to-day problem is rarely a full blackout and much more often the voltage sag that arrives with an afternoon thunderstorm, or the disturbance from a large motor load elsewhere in the building. The unit rides those out on its inverter, holding a 160–280 V full-load input window before it needs the battery at all.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e1000 VA of Protected Capacity, 800 W of Real Power\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRated at \u003cstrong\u003e1000 VA \/ 800 W\u003c\/strong\u003e, the SRVPM1KIL is sized for a small comms cabinet, a single server or a workgroup of network equipment. Size against the watts figure rather than the VA figure — servers, switches and storage are watts loads — and leave headroom rather than running it hard, which costs you both runtime and battery life. On-line efficiency is 88 % at full load, and output distortion is held to 3 %, which is what an active-PFC server power supply expects to see.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eExtended Runtime: Power Module Plus SRV36BP-9A Battery Pack\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis is the \u003cstrong\u003eextended-runtime\u003c\/strong\u003e build. Schneider's own product name for the SRVPM1KIL ends in “Extended runtime, No Battery” — the power module holds no internal batteries and does not operate on its own. SourceIT supplies it as a complete working system with one \u003cstrong\u003eSRV36BP-9A\u003c\/strong\u003e external battery pack (36 V DC), and up to \u003cstrong\u003e4 packs\u003c\/strong\u003e can be connected as your autonomy requirement grows. That is the practical difference from the standard SRV1KI tower, which has fixed internal batteries and accepts no expansion at all. Output is 3 × IEC 60320 C13 (all battery backup and surge protected).\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBatteries, Service Life and Singapore's Heat\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SRV36BP-9A pack uses maintenance-free sealed VRLA blocks, and the system recharges in 4.5 hours. Heat is what actually kills UPS batteries, and a poorly ventilated cabinet in Singapore's climate will take years off them — the unit is rated for 0 °C to 40 °C and runs at 50 dBA, so give it airflow and it will give you the service life the specification implies. Battery condition is readable from the front-panel LCD and, with an \u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e fitted, over the network.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBuy the APC SRVPM1KIL in Singapore with Local Warranty and GST Invoice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the APC SRVPM1KIL from Singapore with a GST invoice and local warranty support, backed by APC's 2-year manufacturer warranty. Tell us the load you need to protect — in watts, and how long you need it to stay up — and we will size the unit, the battery pack count and the network card properly rather than sell you the nearest number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRVPM1KIL Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRVPM1KIL + SRV36BP-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSRVPM1KIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \/ Series\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric — Easy UPS On-Line SRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider product name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line, 1000VA\/800W, Tower, 230V, 3x IEC C13 outlets, Intelligent Card Slot, LCD, Extended runtime, No Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal, configurable for 220 \/ 230 \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz ± 3 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage distortion\u003c\/td\u003e\n\u003ctd\u003e3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3 : 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-line efficiency\u003c\/td\u003e\n\u003ctd\u003e88 % at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput connections\u003c\/td\u003e\n\u003ctd\u003e3 × IEC 60320 C13 (all battery backup and surge protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e600 Joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range\u003c\/td\u003e\n\u003ctd\u003e160–280 V at full load; 110–285 V at half load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed valve-regulated lead-acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e36 V DC bus — supplied entirely by the external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical recharge time\u003c\/td\u003e\n\u003ctd\u003e4.5 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharger rating\u003c\/td\u003e\n\u003ctd\u003e175 W rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected battery life\u003c\/td\u003e\n\u003ctd\u003e3–5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal battery pack\u003c\/td\u003e\n\u003ctd\u003eUp to 4 × SRV36BP-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eYes (USB cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial port\u003c\/td\u003e\n\u003ctd\u003eRS-232, DB-9 (configuration cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimultaneous USB and serial\u003c\/td\u003e\n\u003ctd\u003eNo — the USB and RS-232 ports cannot be used at the same time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard slot\u003c\/td\u003e\n\u003ctd\u003e1 × Intelligent Card Slot (Schneider’s term — not a Smart-UPS “SmartSlot”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork management card\u003c\/td\u003e\n\u003ctd\u003eAPV9601 — APC Easy UPS On-Line SRV SNMP card (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutdown software\u003c\/td\u003e\n\u003ctd\u003eCompatible with PowerChute Serial Shutdown and PowerChute Business Edition — Schneider FAQ FA315835 lists SRV models of 3 kVA and below as supported over USB or serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eNot available on this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm\u003c\/td\u003e\n\u003ctd\u003eOn battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e223 mm (H) × 145 mm (W) × 288 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e4.4 kg net (power module only) \/ 5.9 kg packaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity\u003c\/td\u003e\n\u003ctd\u003e0–95 % relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating elevation\u003c\/td\u003e\n\u003ctd\u003e0–3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible noise\u003c\/td\u003e\n\u003ctd\u003e50 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eExternal Battery Pack — SRV36BP-9A\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRV36BP-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider product name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV Battery Pack (1kVA) for Extended Runtime Model 36V, 648VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC voltage\u003c\/td\u003e\n\u003ctd\u003e36 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e648 VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed VRLA lead-acid, 12 V \/ 9 Ah blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum packs per UPS\u003c\/td\u003e\n\u003ctd\u003eUp to 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider does not publish a replacement battery cartridge part number, the physical dimensions or the net weight of the SRV36BP-9A in any document we could verify, so none is stated above. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e and we will confirm current details with the distributor before you order.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe SRVPM1KIL provides \u003cstrong\u003e3 × IEC 60320 C13 (all battery backup and surge protected)\u003c\/strong\u003e. Every outlet is fed from the inverter, so all of them carry battery backup and surge protection — there is no surge-only bank on this model. Rated capacity is 1000 VA \/ 800 W: size the load against the \u003cstrong\u003e800 W figure\u003c\/strong\u003e, because a server, switch or storage array is a watts load, not a VA load.\u003c\/p\u003e\n\u003ch4\u003eInput and circuit requirements\u003c\/h4\u003e\n\u003cp\u003eInput connection is \u003cstrong\u003eIEC 60320 C14 inlet\u003c\/strong\u003e. Singapore mains is 230 V \/ 50 Hz, which sits comfortably inside this unit's 160–280 V full-load input window, and the on-line inverter regenerates the output waveform continuously rather than switching to battery for every dip — useful during the voltage sags that accompany a thunderstorm on the PUB grid.\u003c\/p\u003e\n\u003ch4\u003eFootprint\u003c\/h4\u003e\n\u003cp\u003eThis is a \u003cstrong\u003etower\u003c\/strong\u003e power module at 223 mm (H) × 145 mm (W) × 288 mm (D) and it is not rack-mountable, and the battery pack is a tower too. Schneider builds a rackmount extended-runtime equivalent under a separate part number in the SRVPM…KRIL series with rackmount battery packs — ask us if a rack build is what you need.\u003c\/p\u003e\n\u003ch4\u003eBatteries and runtime\u003c\/h4\u003e\n\u003cp\u003eThis is an \u003cstrong\u003eextended-runtime power module\u003c\/strong\u003e. Schneider's own product name for it ends in “Extended runtime, No Battery”, and the user manual confirms these units \u003cstrong\u003ehave no internal batteries\u003c\/strong\u003e — an external battery pack must be connected before the UPS will operate. This listing ships the power module together with one \u003cstrong\u003eSRV36BP-9A\u003c\/strong\u003e pack (36 V DC). Up to \u003cstrong\u003e4 packs\u003c\/strong\u003e can be connected for longer autonomy.\u003c\/p\u003e\n\u003cp\u003eRecharge time is 4.5 hours. Schneider publishes \u003cstrong\u003eno runtime table\u003c\/strong\u003e for these extended-runtime bundles that we were able to verify against two independent sources, so no minutes-at-load figures are quoted here. Runtime depends on the connected load, the number of packs fitted and battery age. Tell us your actual load in watts and the autonomy you need and we will size the pack count for you — \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch4\u003eManagement options\u003c\/h4\u003e\n\u003cp\u003eThe SRVPM1KIL has a USB port, an RS-232 DB-9 serial port and one \u003cstrong\u003eIntelligent Card Slot\u003c\/strong\u003e. Schneider's card for that slot is the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e. The Easy UPS On-Line SRV range uses a different card family from Smart-UPS: the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will \u003cstrong\u003enot\u003c\/strong\u003e work in this UPS.\u003c\/p\u003e\n\u003cp\u003eFor direct USB or serial shutdown of a single host, Schneider's FAQ FA315835 lists SRV models of 3 kVA and below as supported by PowerChute Serial Shutdown and PowerChute Business Edition. PowerChute itself is a Schneider download rather than a licence sold with the UPS — ask us if you want the current version confirmed for your operating system before you commission.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 × RS-232 signalling cable\u003c\/li\u003e\n\u003cli\u003e1 × USB cable\u003c\/li\u003e\n\u003cli\u003e1 × DC cable to the battery pack\u003c\/li\u003e\n\u003cli\u003e1 × country-specific power cord\u003c\/li\u003e\n\u003cli\u003e1 × SRV36BP-9A external battery pack\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider documents a “country-specific power cord” in this carton without naming the plug type. Tell us how you intend to power it — rack PDU, wall socket or a fixed supply — and we will confirm what ships in the Singapore carton and supply the right cordage with the order.\u003c\/p\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — tower models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-230v-srv1ki\"\u003eAPC Easy UPS On-Line SRV1KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-srv2ki\"\u003eAPC Easy UPS On-Line SRV2KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-srv3ki\"\u003eAPC Easy UPS On-Line SRV3KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — rackmount 2U models (supplied with SRVRK1 rail kit)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri\"\u003eAPC Easy UPS On-Line SRV1KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri\"\u003eAPC Easy UPS On-Line SRV2KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri\"\u003eAPC Easy UPS On-Line SRV3KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eExtended-runtime models (no internal battery, external pack supplied)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery pack\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRVPM1KIL (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · SRV36BP-9A (36 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-with-extended-runtime-battery-pack-srv2kil\"\u003eAPC Easy UPS On-Line SRVPM2KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-with-extended-runtime-battery-pack-srv3kil\"\u003eAPC Easy UPS On-Line SRVPM3KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eLarger Easy UPS On-Line SRV models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity and format\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-6000va-230v-srv6ki\"\u003eAPC Easy UPS On-Line SRV6KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-10000va-230v-srv10ki\"\u003eAPC Easy UPS On-Line SRV10KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-6000va-230v-with-railkit-external-battery-pack-srv6krirk\"\u003eAPC Easy UPS On-Line SRV6KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-railkit-external-battery-pack-srv10krirk\"\u003eAPC Easy UPS On-Line SRV10KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eAccessories for this UPS\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWhat it is\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPC Easy UPS On-Line SRV SNMP Card (APV9601)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSNMP network management card for the Intelligent Card Slot. The correct card for Easy UPS On-Line SRV — the Smart-UPS AP9640 and AP9641 cards do not fit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV36BP-9A\u003c\/td\u003e\n\u003ctd\u003eAdditional external battery pack — up to 4 can be connected to this power module for longer autonomy. Ordered separately; email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e for pricing and lead time.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/SRVPM1KIL\/apc-easy-ups-online-1000va-800w-tower-230v-3x-iec-c13-outlets-intelligent-card-slot-lcd-extended-runtime-no-battery\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Schneider Electric product page for the APC SRVPM1KIL\u003c\/a\u003e — United Kingdom (no Singapore page is published for this part number) regional page. Schneider publishes the product datasheet, user guide and environmental disclosure from the document list on that page.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/SRV36BP-9A\/apc-easy-ups-online-srv-battery-pack-1kva-for-extended-runtime-model-36v-648vah\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Schneider Electric product page for the SRV36BP-9A external battery pack\u003c\/a\u003e supplied with this UPS — Singapore regional page.\u003c\/p\u003e\n\u003cp\u003eSchneider serves its APC datasheet PDFs from a redirecting download host that regularly returns the wrong model's document, so we do not publish direct PDF links that we cannot verify resolve to the right part number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with the model you need and we will send the correct current-revision datasheet and user manual, along with a GST-invoiced quotation.\u003c\/p\u003e\n\u003cp\u003eEvery specification on this page was taken from Schneider Electric's own product page and its published product datasheet or user manual for this exact part number. Where Schneider's own sources disagreed, or published nothing, the field has been left out rather than estimated.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRVPM1KIL\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 1000 VA and 800 W ratings, and how do I size it?\u003c\/h4\u003e\n\u003cp\u003eVA is apparent power, watts is real power. The SRVPM1KIL is rated 1000 VA \/ 800 W, an output power factor of 0.8. Add up the watts of everything you intend to protect, keep the total under 800 W, and leave headroom — loading a UPS to 100 % shortens both runtime and battery life. As a rough Singapore rule of thumb, a 1U rack server draws 200–400 W, a 24-port PoE switch 150–400 W depending on how much PoE is actually drawn, and a small NAS 60–120 W. Send us the list and we will size it.\u003c\/p\u003e\n\u003ch4\u003eHow long will the SRVPM1KIL run my equipment?\u003c\/h4\u003e\n\u003cp\u003eSchneider does not publish a runtime-at-load table for this model that we could verify against two independent official sources, so we do not quote minutes here rather than invent them.\u003c\/p\u003e\n\u003cp\u003eWhat matters in practice is that autonomy on this build is set by how many \u003cstrong\u003eSRV36BP-9A\u003c\/strong\u003e packs you fit, not by anything inside the UPS — up to 4 can be connected. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with your load in watts and the autonomy you want and we will work out the pack count.\u003c\/p\u003e\n\u003ch4\u003eIs the output a true sine wave, and will it work with an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eYes. Schneider's datasheet for this exact model states a \u003cstrong\u003esine wave\u003c\/strong\u003e output with 3 % voltage distortion, and the topology is \u003cstrong\u003edouble conversion on-line\u003c\/strong\u003e — the load is fed from the inverter continuously rather than being switched over when mains fails. That is what an active-PFC server or workstation PSU wants; the step-approximated output of a low-cost standby UPS is what causes those supplies to trip. Schneider does not publish a numeric transfer time for this model and we do not claim one.\u003c\/p\u003e\n\u003ch4\u003eWhat does the “PM” in SRVPM1KIL mean, and does it come with batteries?\u003c\/h4\u003e\n\u003cp\u003ePM stands for \u003cstrong\u003epower module\u003c\/strong\u003e. Schneider's product name for it ends in “Extended runtime, No Battery” and the user manual confirms these units contain no internal batteries at all — they will not operate until an external battery pack is connected. \u003cstrong\u003eThis SourceIT listing is a complete working system\u003c\/strong\u003e: the SRVPM1KIL power module supplied together with one SRV36BP-9A battery pack (36 V DC). Up to 4 packs can be connected. Schneider also markets the same combination under the bundle designation SRV1KIL.\u003c\/p\u003e\n\u003ch4\u003eCan I add more battery packs later?\u003c\/h4\u003e\n\u003cp\u003eYes — up to \u003cstrong\u003e4 SRV36BP-9A packs\u003c\/strong\u003e can be connected to this power module. The batteries are the pack's, so autonomy scales with pack count rather than with anything inside the UPS. Schneider publishes no verified runtime matrix for these combinations, so rather than quote numbers we will size it against your measured load. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch4\u003eCan the SRVPM1KIL be rack mounted?\u003c\/h4\u003e\n\u003cp\u003eNo. This is a tower unit at 223 mm (H) × 145 mm (W) × 288 mm (D). Schneider builds the rackmount version as a separate part number — the SRVPM…KRIL rackmount extended-runtime series, which we can quote on request. The two are not convertible, and their outlet counts and dimensions differ, so pick the form factor at the point of order.\u003c\/p\u003e\n\u003ch4\u003eHow do I monitor it over the network?\u003c\/h4\u003e\n\u003cp\u003eFit the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e in the UPS Intelligent Card Slot. That is the Easy UPS On-Line card — the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will not work here. Without a card you still get USB and RS-232 for a direct shutdown link to one host, with PowerChute Serial Shutdown or PowerChute Business Edition. Note that Schneider has discontinued the APV9601; ask us about current stock and the AP9544 successor before you commit to a monitoring design.\u003c\/p\u003e\n\u003ch4\u003eIs the SRVPM1KIL covered by warranty in Singapore?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC SRVPM1KIL sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRVPM1KIL with a 2-year manufacturer warranty. Schneider publishes a single worldwide figure of “2 years repair or replace” for the Easy UPS On-Line SRV range — there is no separate European and rest-of-world split on this family, so the term above is the one that applies in Singapore.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bzQk-YuLvCM\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039336562852,"sku":"SRVPM1KIL + SRV36BP-9A","price":785.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/SRV1KIL.png?v=1671696082"},{"product_id":"apc-easy-ups-on-line-srv-2000va-230v-with-extended-runtime-battery-pack-srv2kil","title":"APC Easy UPS On-Line 2000VA, Ext. Runtime","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Easy UPS On-Line 2000VA, Ext. Runtime (SRVPM2KIL) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDouble-Conversion On-Line Protection for Singapore's 230 V \/ 50 Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC SRVPM2KIL is a \u003cstrong\u003edouble-conversion on-line UPS\u003c\/strong\u003e: incoming mains is rectified to DC and rebuilt as a clean sine wave output, so the connected load never sees the supply it is actually plugged into. That matters on the Singapore grid, where the day-to-day problem is rarely a full blackout and much more often the voltage sag that arrives with an afternoon thunderstorm, or the disturbance from a large motor load elsewhere in the building. The unit rides those out on its inverter, holding a 160–280 V full-load input window before it needs the battery at all.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e2000 VA of Protected Capacity, 1600 W of Real Power\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRated at \u003cstrong\u003e2000 VA \/ 1600 W\u003c\/strong\u003e, the SRVPM2KIL is sized for a comms cabinet, a pair of servers or a PoE switch stack. Size against the watts figure rather than the VA figure — servers, switches and storage are watts loads — and leave headroom rather than running it hard, which costs you both runtime and battery life. On-line efficiency is 88 % at full load, and output distortion is held to 3 %, which is what an active-PFC server power supply expects to see.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eExtended Runtime: Power Module Plus SRV72BP-9A Battery Pack\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis is the \u003cstrong\u003eextended-runtime\u003c\/strong\u003e build. Schneider's own product name for the SRVPM2KIL ends in “Extended runtime, No Battery” — the power module holds no internal batteries and does not operate on its own. SourceIT supplies it as a complete working system with one \u003cstrong\u003eSRV72BP-9A\u003c\/strong\u003e external battery pack (72 V DC), and up to \u003cstrong\u003e4 packs\u003c\/strong\u003e can be connected as your autonomy requirement grows. That is the practical difference from the standard SRV2KI tower, which has fixed internal batteries and accepts no expansion at all. Output is 4 × IEC 60320 C13 (all battery backup and surge protected).\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBatteries, Service Life and Singapore's Heat\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SRV72BP-9A pack uses maintenance-free sealed VRLA blocks, and the system recharges in 5.5 hours. Heat is what actually kills UPS batteries, and a poorly ventilated cabinet in Singapore's climate will take years off them — the unit is rated for 0 °C to 40 °C and runs at 50 dBA, so give it airflow and it will give you the service life the specification implies. Battery condition is readable from the front-panel LCD and, with an \u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e fitted, over the network.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBuy the APC SRVPM2KIL in Singapore with Local Warranty and GST Invoice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the APC SRVPM2KIL from Singapore with a GST invoice and local warranty support, backed by APC's 2-year manufacturer warranty. Tell us the load you need to protect — in watts, and how long you need it to stay up — and we will size the unit, the battery pack count and the network card properly rather than sell you the nearest number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRVPM2KIL Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRVPM2KIL + SRV72BP-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSRVPM2KIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \/ Series\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric — Easy UPS On-Line SRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal, configurable for 220 \/ 230 \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz ± 3 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage distortion\u003c\/td\u003e\n\u003ctd\u003e3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3 : 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-line efficiency\u003c\/td\u003e\n\u003ctd\u003e88 % at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput connections\u003c\/td\u003e\n\u003ctd\u003e4 × IEC 60320 C13 (all battery backup and surge protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e600 Joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range\u003c\/td\u003e\n\u003ctd\u003e160–280 V at full load; 110–285 V at half load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed valve-regulated lead-acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e72 V DC bus — supplied entirely by the external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical recharge time\u003c\/td\u003e\n\u003ctd\u003e5.5 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharger rating\u003c\/td\u003e\n\u003ctd\u003e350 W rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected battery life\u003c\/td\u003e\n\u003ctd\u003e3–5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal battery pack\u003c\/td\u003e\n\u003ctd\u003eUp to 4 × SRV72BP-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eYes (USB cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial port\u003c\/td\u003e\n\u003ctd\u003eRS-232, DB-9 (configuration cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimultaneous USB and serial\u003c\/td\u003e\n\u003ctd\u003eNo — the USB and RS-232 ports cannot be used at the same time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard slot\u003c\/td\u003e\n\u003ctd\u003e1 × Intelligent Card Slot (Schneider’s term — not a Smart-UPS “SmartSlot”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork management card\u003c\/td\u003e\n\u003ctd\u003eAPV9601 — APC Easy UPS On-Line SRV SNMP card (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutdown software\u003c\/td\u003e\n\u003ctd\u003eCompatible with PowerChute Serial Shutdown and PowerChute Business Edition — Schneider FAQ FA315835 lists SRV models of 3 kVA and below as supported over USB or serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eNot available on this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm\u003c\/td\u003e\n\u003ctd\u003eOn battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e238 mm (H) × 145 mm (W) × 400 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e7.4 kg net (power module only) \/ 9.1 kg packaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComplete system weight\u003c\/td\u003e\n\u003ctd\u003e45.4 kg net for the complete SRV2KIL system (power module plus one battery pack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity\u003c\/td\u003e\n\u003ctd\u003e0–95 % relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating elevation\u003c\/td\u003e\n\u003ctd\u003e0–3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible noise\u003c\/td\u003e\n\u003ctd\u003e50 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eExternal Battery Pack — SRV72BP-9A\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRV72BP-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider product name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV Battery Pack for 2\/3kVA Extended runtime model, 72V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC voltage\u003c\/td\u003e\n\u003ctd\u003e72 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed VRLA lead-acid, 12 V \/ 9 Ah blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum packs per UPS\u003c\/td\u003e\n\u003ctd\u003eUp to 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider does not publish a replacement battery cartridge part number, the physical dimensions or the net weight of the SRV72BP-9A in any document we could verify, so none is stated above. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e and we will confirm current details with the distributor before you order.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe SRVPM2KIL provides \u003cstrong\u003e4 × IEC 60320 C13 (all battery backup and surge protected)\u003c\/strong\u003e. Every outlet is fed from the inverter, so all of them carry battery backup and surge protection — there is no surge-only bank on this model. Rated capacity is 2000 VA \/ 1600 W: size the load against the \u003cstrong\u003e1600 W figure\u003c\/strong\u003e, because a server, switch or storage array is a watts load, not a VA load.\u003c\/p\u003e\n\u003ch4\u003eInput and circuit requirements\u003c\/h4\u003e\n\u003cp\u003eInput connection is \u003cstrong\u003eIEC 60320 C14 inlet\u003c\/strong\u003e. Singapore mains is 230 V \/ 50 Hz, which sits comfortably inside this unit's 160–280 V full-load input window, and the on-line inverter regenerates the output waveform continuously rather than switching to battery for every dip — useful during the voltage sags that accompany a thunderstorm on the PUB grid.\u003c\/p\u003e\n\u003ch4\u003eFootprint\u003c\/h4\u003e\n\u003cp\u003eThis is a \u003cstrong\u003etower\u003c\/strong\u003e power module at 238 mm (H) × 145 mm (W) × 400 mm (D) and it is not rack-mountable, and the battery pack is a tower too. Schneider builds a rackmount extended-runtime equivalent under a separate part number in the SRVPM…KRIL series with rackmount battery packs — ask us if a rack build is what you need.\u003c\/p\u003e\n\u003ch4\u003eBatteries and runtime\u003c\/h4\u003e\n\u003cp\u003eThis is an \u003cstrong\u003eextended-runtime power module\u003c\/strong\u003e. Schneider's own product name for it ends in “Extended runtime, No Battery”, and the user manual confirms these units \u003cstrong\u003ehave no internal batteries\u003c\/strong\u003e — an external battery pack must be connected before the UPS will operate. This listing ships the power module together with one \u003cstrong\u003eSRV72BP-9A\u003c\/strong\u003e pack (72 V DC). Up to \u003cstrong\u003e4 packs\u003c\/strong\u003e can be connected for longer autonomy.\u003c\/p\u003e\n\u003cp\u003eRecharge time is 5.5 hours. Schneider publishes \u003cstrong\u003eno runtime table\u003c\/strong\u003e for these extended-runtime bundles that we were able to verify against two independent sources, so no minutes-at-load figures are quoted here. Runtime depends on the connected load, the number of packs fitted and battery age. Tell us your actual load in watts and the autonomy you need and we will size the pack count for you — \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch4\u003eManagement options\u003c\/h4\u003e\n\u003cp\u003eThe SRVPM2KIL has a USB port, an RS-232 DB-9 serial port and one \u003cstrong\u003eIntelligent Card Slot\u003c\/strong\u003e. Schneider's card for that slot is the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e. The Easy UPS On-Line SRV range uses a different card family from Smart-UPS: the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will \u003cstrong\u003enot\u003c\/strong\u003e work in this UPS.\u003c\/p\u003e\n\u003cp\u003eFor direct USB or serial shutdown of a single host, Schneider's FAQ FA315835 lists SRV models of 3 kVA and below as supported by PowerChute Serial Shutdown and PowerChute Business Edition. PowerChute itself is a Schneider download rather than a licence sold with the UPS — ask us if you want the current version confirmed for your operating system before you commission.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 × RS-232 signalling cable\u003c\/li\u003e\n\u003cli\u003e1 × USB cable\u003c\/li\u003e\n\u003cli\u003e1 × DC cable to the battery pack\u003c\/li\u003e\n\u003cli\u003e1 × country-specific power cord\u003c\/li\u003e\n\u003cli\u003e1 × SRV72BP-9A external battery pack\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider documents a “country-specific power cord” in this carton without naming the plug type. Tell us how you intend to power it — rack PDU, wall socket or a fixed supply — and we will confirm what ships in the Singapore carton and supply the right cordage with the order.\u003c\/p\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — tower models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-230v-srv1ki\"\u003eAPC Easy UPS On-Line SRV1KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-srv2ki\"\u003eAPC Easy UPS On-Line SRV2KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-srv3ki\"\u003eAPC Easy UPS On-Line SRV3KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — rackmount 2U models (supplied with SRVRK1 rail kit)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri\"\u003eAPC Easy UPS On-Line SRV1KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri\"\u003eAPC Easy UPS On-Line SRV2KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri\"\u003eAPC Easy UPS On-Line SRV3KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eExtended-runtime models (no internal battery, external pack supplied)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery pack\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-external-battery-pack-srv3kri\"\u003eAPC Easy UPS On-Line SRVPM1KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · SRV36BP-9A (36 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRVPM2KIL (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-with-extended-runtime-battery-pack-srv3kil\"\u003eAPC Easy UPS On-Line SRVPM3KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eLarger Easy UPS On-Line SRV models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity and format\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-6000va-230v-srv6ki\"\u003eAPC Easy UPS On-Line SRV6KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-10000va-230v-srv10ki\"\u003eAPC Easy UPS On-Line SRV10KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-6000va-230v-with-railkit-external-battery-pack-srv6krirk\"\u003eAPC Easy UPS On-Line SRV6KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-railkit-external-battery-pack-srv10krirk\"\u003eAPC Easy UPS On-Line SRV10KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eAccessories for this UPS\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWhat it is\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPC Easy UPS On-Line SRV SNMP Card (APV9601)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSNMP network management card for the Intelligent Card Slot. The correct card for Easy UPS On-Line SRV — the Smart-UPS AP9640 and AP9641 cards do not fit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV72BP-9A\u003c\/td\u003e\n\u003ctd\u003eAdditional external battery pack — up to 4 can be connected to this power module for longer autonomy. Ordered separately; email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e for pricing and lead time.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eSchneider Electric does not publish an English-language product page for the \u003cstrong\u003eSRVPM2KIL\u003c\/strong\u003e part number in any region we could verify, so no direct link is given here rather than sending you to a page for a different model.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/SRV72BP-9A\/apc-easy-ups-online-srv-battery-pack-for-2-3kva-extended-runtime-model-72v\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Schneider Electric product page for the SRV72BP-9A external battery pack\u003c\/a\u003e supplied with this UPS — Singapore regional page.\u003c\/p\u003e\n\u003cp\u003eSchneider serves its APC datasheet PDFs from a redirecting download host that regularly returns the wrong model's document, so we do not publish direct PDF links that we cannot verify resolve to the right part number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with the model you need and we will send the correct current-revision datasheet and user manual, along with a GST-invoiced quotation.\u003c\/p\u003e\n\u003cp\u003eEvery specification on this page was taken from Schneider Electric's own product page and its published product datasheet or user manual for this exact part number. Where Schneider's own sources disagreed, or published nothing, the field has been left out rather than estimated.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRVPM2KIL\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 2000 VA and 1600 W ratings, and how do I size it?\u003c\/h4\u003e\n\u003cp\u003eVA is apparent power, watts is real power. The SRVPM2KIL is rated 2000 VA \/ 1600 W, an output power factor of 0.8. Add up the watts of everything you intend to protect, keep the total under 1600 W, and leave headroom — loading a UPS to 100 % shortens both runtime and battery life. As a rough Singapore rule of thumb, a 1U rack server draws 200–400 W, a 24-port PoE switch 150–400 W depending on how much PoE is actually drawn, and a small NAS 60–120 W. Send us the list and we will size it.\u003c\/p\u003e\n\u003ch4\u003eHow long will the SRVPM2KIL run my equipment?\u003c\/h4\u003e\n\u003cp\u003eSchneider does not publish a runtime-at-load table for this model that we could verify against two independent official sources, so we do not quote minutes here rather than invent them.\u003c\/p\u003e\n\u003cp\u003eWhat matters in practice is that autonomy on this build is set by how many \u003cstrong\u003eSRV72BP-9A\u003c\/strong\u003e packs you fit, not by anything inside the UPS — up to 4 can be connected. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with your load in watts and the autonomy you want and we will work out the pack count.\u003c\/p\u003e\n\u003ch4\u003eIs the output a true sine wave, and will it work with an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eYes. Schneider's datasheet for this exact model states a \u003cstrong\u003esine wave\u003c\/strong\u003e output with 3 % voltage distortion, and the topology is \u003cstrong\u003edouble conversion on-line\u003c\/strong\u003e — the load is fed from the inverter continuously rather than being switched over when mains fails. That is what an active-PFC server or workstation PSU wants; the step-approximated output of a low-cost standby UPS is what causes those supplies to trip. Schneider does not publish a numeric transfer time for this model and we do not claim one.\u003c\/p\u003e\n\u003ch4\u003eWhat does the “PM” in SRVPM2KIL mean, and does it come with batteries?\u003c\/h4\u003e\n\u003cp\u003ePM stands for \u003cstrong\u003epower module\u003c\/strong\u003e. Schneider's product name for it ends in “Extended runtime, No Battery” and the user manual confirms these units contain no internal batteries at all — they will not operate until an external battery pack is connected. \u003cstrong\u003eThis SourceIT listing is a complete working system\u003c\/strong\u003e: the SRVPM2KIL power module supplied together with one SRV72BP-9A battery pack (72 V DC). Up to 4 packs can be connected. Schneider also markets the same combination under the bundle designation SRV2KIL.\u003c\/p\u003e\n\u003ch4\u003eCan I add more battery packs later?\u003c\/h4\u003e\n\u003cp\u003eYes — up to \u003cstrong\u003e4 SRV72BP-9A packs\u003c\/strong\u003e can be connected to this power module. The batteries are the pack's, so autonomy scales with pack count rather than with anything inside the UPS. Schneider publishes no verified runtime matrix for these combinations, so rather than quote numbers we will size it against your measured load. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch4\u003eCan the SRVPM2KIL be rack mounted?\u003c\/h4\u003e\n\u003cp\u003eNo. This is a tower unit at 238 mm (H) × 145 mm (W) × 400 mm (D). Schneider builds the rackmount version as a separate part number — the SRVPM…KRIL rackmount extended-runtime series, which we can quote on request. The two are not convertible, and their outlet counts and dimensions differ, so pick the form factor at the point of order.\u003c\/p\u003e\n\u003ch4\u003eHow do I monitor it over the network?\u003c\/h4\u003e\n\u003cp\u003eFit the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e in the UPS Intelligent Card Slot. That is the Easy UPS On-Line card — the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will not work here. Without a card you still get USB and RS-232 for a direct shutdown link to one host, with PowerChute Serial Shutdown or PowerChute Business Edition. Note that Schneider has discontinued the APV9601; ask us about current stock and the AP9544 successor before you commit to a monitoring design.\u003c\/p\u003e\n\u003ch4\u003eIs the SRVPM2KIL covered by warranty in Singapore?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC SRVPM2KIL sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRVPM2KIL with a 2-year manufacturer warranty. Schneider publishes a single worldwide figure of “2 years repair or replace” for the Easy UPS On-Line SRV range — there is no separate European and rest-of-world split on this family, so the term above is the one that applies in Singapore.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bzQk-YuLvCM\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039358714020,"sku":"SRVPM2KIL + SRV72BP-9A","price":1325.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-easy-ups-on-line-srv-2000va-230v-with-extended-runtime-battery-pack-srv2kil-924685.jpg?v=1702980108"},{"product_id":"apc-easy-ups-on-line-srv-3000va-230v-with-extended-runtime-battery-pack-srv3kil","title":"APC Easy UPS On-Line 3000VA, Ext. Runtime","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Easy UPS On-Line 3000VA, Ext. Runtime (SRVPM3KIL) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDouble-Conversion On-Line Protection for Singapore's 230 V \/ 50 Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC SRVPM3KIL is a \u003cstrong\u003edouble-conversion on-line UPS\u003c\/strong\u003e: incoming mains is rectified to DC and rebuilt as a clean sine wave output, so the connected load never sees the supply it is actually plugged into. That matters on the Singapore grid, where the day-to-day problem is rarely a full blackout and much more often the voltage sag that arrives with an afternoon thunderstorm, or the disturbance from a large motor load elsewhere in the building. The unit rides those out on its inverter, holding a 160–280 V full-load input window before it needs the battery at all.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e3000 VA of Protected Capacity, 2400 W of Real Power\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRated at \u003cstrong\u003e3000 VA \/ 2400 W\u003c\/strong\u003e, the SRVPM3KIL is sized for a loaded comms cabinet, a small server room or a rack of network and storage equipment. Size against the watts figure rather than the VA figure — servers, switches and storage are watts loads — and leave headroom rather than running it hard, which costs you both runtime and battery life. On-line efficiency is 88 % at full load, and output distortion is held to 3 %, which is what an active-PFC server power supply expects to see.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eExtended Runtime: Power Module Plus SRV72BP-9A Battery Pack\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis is the \u003cstrong\u003eextended-runtime\u003c\/strong\u003e build. Schneider's own product name for the SRVPM3KIL ends in “Extended runtime, No Battery” — the power module holds no internal batteries and does not operate on its own. SourceIT supplies it as a complete working system with one \u003cstrong\u003eSRV72BP-9A\u003c\/strong\u003e external battery pack (72 V DC), and up to \u003cstrong\u003e4 packs\u003c\/strong\u003e can be connected as your autonomy requirement grows. That is the practical difference from the standard SRV3KI tower, which has fixed internal batteries and accepts no expansion at all. Output is 6 × IEC 60320 C13 + 1 × IEC 60320 C19 (all battery backup and surge protected).\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBatteries, Service Life and Singapore's Heat\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SRV72BP-9A pack uses maintenance-free sealed VRLA blocks, and the system recharges in 4 hours. Heat is what actually kills UPS batteries, and a poorly ventilated cabinet in Singapore's climate will take years off them — the unit is rated for 0 °C to 40 °C and runs at 50 dBA, so give it airflow and it will give you the service life the specification implies. Battery condition is readable from the front-panel LCD and, with an \u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e fitted, over the network.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBuy the APC SRVPM3KIL in Singapore with Local Warranty and GST Invoice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the APC SRVPM3KIL from Singapore with a GST invoice and local warranty support, backed by APC's 2-year manufacturer warranty. Tell us the load you need to protect — in watts, and how long you need it to stay up — and we will size the unit, the battery pack count and the network card properly rather than sell you the nearest number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRVPM3KIL Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRVPM3KIL + SRV72BP-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSRVPM3KIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \/ Series\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric — Easy UPS On-Line SRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider product name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line, 3kVA\/2.4kW, Tower, 230V, 6x IEC C13 + 1x IEC C19 outlets, Intelligent Card Slot, LCD, Extended runtime, No Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal, configurable for 220 \/ 230 \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz ± 3 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage distortion\u003c\/td\u003e\n\u003ctd\u003e3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3 : 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-line efficiency\u003c\/td\u003e\n\u003ctd\u003e88 % at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput connections\u003c\/td\u003e\n\u003ctd\u003e6 × IEC 60320 C13 + 1 × IEC 60320 C19 (all battery backup and surge protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e600 Joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range\u003c\/td\u003e\n\u003ctd\u003e160–280 V at full load; 110–285 V at half load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed valve-regulated lead-acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e72 V DC bus — supplied entirely by the external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical recharge time\u003c\/td\u003e\n\u003ctd\u003e4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected battery life\u003c\/td\u003e\n\u003ctd\u003e3–5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal battery pack\u003c\/td\u003e\n\u003ctd\u003eUp to 4 × SRV72BP-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eYes (USB cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial port\u003c\/td\u003e\n\u003ctd\u003eRS-232, DB-9 (configuration cable supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimultaneous USB and serial\u003c\/td\u003e\n\u003ctd\u003eNo — the USB and RS-232 ports cannot be used at the same time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard slot\u003c\/td\u003e\n\u003ctd\u003e1 × Intelligent Card Slot (Schneider’s term — not a Smart-UPS “SmartSlot”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork management card\u003c\/td\u003e\n\u003ctd\u003eAPV9601 — APC Easy UPS On-Line SRV SNMP card (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShutdown software\u003c\/td\u003e\n\u003ctd\u003eCompatible with PowerChute Serial Shutdown and PowerChute Business Edition — Schneider FAQ FA315835 lists SRV models of 3 kVA and below as supported over USB or serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eNot available on this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm\u003c\/td\u003e\n\u003ctd\u003eOn battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e336 mm (H) × 190 mm (W) × 425 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e7.9 kg net (power module only) \/ 9.6 kg packaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComplete system weight\u003c\/td\u003e\n\u003ctd\u003e45.9 kg net for the complete SRV3KIL system (power module plus one battery pack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity\u003c\/td\u003e\n\u003ctd\u003e0–95 % relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating elevation\u003c\/td\u003e\n\u003ctd\u003e0–3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible noise\u003c\/td\u003e\n\u003ctd\u003e50 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eExternal Battery Pack — SRV72BP-9A\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRV72BP-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider product name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV Battery Pack for 2\/3kVA Extended runtime model, 72V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC voltage\u003c\/td\u003e\n\u003ctd\u003e72 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed VRLA lead-acid, 12 V \/ 9 Ah blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum packs per UPS\u003c\/td\u003e\n\u003ctd\u003eUp to 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider does not publish a replacement battery cartridge part number, the physical dimensions or the net weight of the SRV72BP-9A in any document we could verify, so none is stated above. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e and we will confirm current details with the distributor before you order.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe SRVPM3KIL provides \u003cstrong\u003e6 × IEC 60320 C13 + 1 × IEC 60320 C19 (all battery backup and surge protected)\u003c\/strong\u003e. Every outlet is fed from the inverter, so all of them carry battery backup and surge protection — there is no surge-only bank on this model. Rated capacity is 3000 VA \/ 2400 W: size the load against the \u003cstrong\u003e2400 W figure\u003c\/strong\u003e, because a server, switch or storage array is a watts load, not a VA load.\u003c\/p\u003e\n\u003cp\u003eThe single IEC C19 outlet is the one to reserve for a higher-draw device — a blade chassis, a large PSU or a rack PDU feeding a sub-bank. Note this model has \u003cstrong\u003eone\u003c\/strong\u003e C19, not two.\u003c\/p\u003e\n\u003ch4\u003eInput and circuit requirements\u003c\/h4\u003e\n\u003cp\u003eSingapore mains is 230 V \/ 50 Hz, which sits comfortably inside this unit's 160–280 V full-load input window, and the on-line inverter regenerates the output waveform continuously rather than switching to battery for every dip. The input connector type printed in Schneider's documentation for this power module is inconsistent with its 2400 W rating, so we have not published a figure — email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e and we will confirm the inlet on the actual Singapore stock before you order cabling.\u003c\/p\u003e\n\u003ch4\u003eFootprint\u003c\/h4\u003e\n\u003cp\u003eThis is a \u003cstrong\u003etower\u003c\/strong\u003e power module at 336 mm (H) × 190 mm (W) × 425 mm (D) and it is not rack-mountable, and the battery pack is a tower too. Schneider builds a rackmount extended-runtime equivalent under a separate part number in the SRVPM…KRIL series with rackmount battery packs — ask us if a rack build is what you need.\u003c\/p\u003e\n\u003ch4\u003eBatteries and runtime\u003c\/h4\u003e\n\u003cp\u003eThis is an \u003cstrong\u003eextended-runtime power module\u003c\/strong\u003e. Schneider's own product name for it ends in “Extended runtime, No Battery”, and the user manual confirms these units \u003cstrong\u003ehave no internal batteries\u003c\/strong\u003e — an external battery pack must be connected before the UPS will operate. This listing ships the power module together with one \u003cstrong\u003eSRV72BP-9A\u003c\/strong\u003e pack (72 V DC). Up to \u003cstrong\u003e4 packs\u003c\/strong\u003e can be connected for longer autonomy.\u003c\/p\u003e\n\u003cp\u003eRecharge time is 4 hours. Schneider publishes \u003cstrong\u003eno runtime table\u003c\/strong\u003e for these extended-runtime bundles that we were able to verify against two independent sources, so no minutes-at-load figures are quoted here. Runtime depends on the connected load, the number of packs fitted and battery age. Tell us your actual load in watts and the autonomy you need and we will size the pack count for you — \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch4\u003eManagement options\u003c\/h4\u003e\n\u003cp\u003eThe SRVPM3KIL has a USB port, an RS-232 DB-9 serial port and one \u003cstrong\u003eIntelligent Card Slot\u003c\/strong\u003e. Schneider's card for that slot is the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e. The Easy UPS On-Line SRV range uses a different card family from Smart-UPS: the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will \u003cstrong\u003enot\u003c\/strong\u003e work in this UPS.\u003c\/p\u003e\n\u003cp\u003eFor direct USB or serial shutdown of a single host, Schneider's FAQ FA315835 lists SRV models of 3 kVA and below as supported by PowerChute Serial Shutdown and PowerChute Business Edition. PowerChute itself is a Schneider download rather than a licence sold with the UPS — ask us if you want the current version confirmed for your operating system before you commission.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 × RS-232 signalling cable\u003c\/li\u003e\n\u003cli\u003e1 × USB cable\u003c\/li\u003e\n\u003cli\u003e1 × DC cable to the battery pack\u003c\/li\u003e\n\u003cli\u003e1 × country-specific power cord\u003c\/li\u003e\n\u003cli\u003e1 × SRV72BP-9A external battery pack\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider documents a “country-specific power cord” in this carton without naming the plug type. Tell us how you intend to power it — rack PDU, wall socket or a fixed supply — and we will confirm what ships in the Singapore carton and supply the right cordage with the order.\u003c\/p\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — tower models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-230v-srv1ki\"\u003eAPC Easy UPS On-Line SRV1KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-srv2ki\"\u003eAPC Easy UPS On-Line SRV2KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-srv3ki\"\u003eAPC Easy UPS On-Line SRV3KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eEasy UPS On-Line SRV 1–3 kVA — rackmount 2U models (supplied with SRVRK1 rail kit)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri\"\u003eAPC Easy UPS On-Line SRV1KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri\"\u003eAPC Easy UPS On-Line SRV2KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri\"\u003eAPC Easy UPS On-Line SRV3KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eExtended-runtime models (no internal battery, external pack supplied)\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and battery pack\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-external-battery-pack-srv3kri\"\u003eAPC Easy UPS On-Line SRVPM1KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · SRV36BP-9A (36 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-with-extended-runtime-battery-pack-srv2kil\"\u003eAPC Easy UPS On-Line SRVPM2KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRVPM3KIL (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · SRV72BP-9A (72 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eLarger Easy UPS On-Line SRV models\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity and format\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-6000va-230v-srv6ki\"\u003eAPC Easy UPS On-Line SRV6KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-10000va-230v-srv10ki\"\u003eAPC Easy UPS On-Line SRV10KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-6000va-230v-with-railkit-external-battery-pack-srv6krirk\"\u003eAPC Easy UPS On-Line SRV6KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-railkit-external-battery-pack-srv10krirk\"\u003eAPC Easy UPS On-Line SRV10KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA rackmount with rail kit and external battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eAccessories for this UPS\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWhat it is\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPC Easy UPS On-Line SRV SNMP Card (APV9601)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSNMP network management card for the Intelligent Card Slot. The correct card for Easy UPS On-Line SRV — the Smart-UPS AP9640 and AP9641 cards do not fit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV72BP-9A\u003c\/td\u003e\n\u003ctd\u003eAdditional external battery pack — up to 4 can be connected to this power module for longer autonomy. Ordered separately; email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e for pricing and lead time.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/SRVPM3KIL\/apc-easy-ups-online-3kva-2-4kw-tower-230v-6x-iec-c13-+-1x-iec-c19-outlets-intelligent-card-slot-lcd-extended-runtime-no-battery\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Schneider Electric product page for the APC SRVPM3KIL\u003c\/a\u003e — United Kingdom (no Singapore page is published for this part number) regional page. Schneider publishes the product datasheet, user guide and environmental disclosure from the document list on that page.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/SRV72BP-9A\/apc-easy-ups-online-srv-battery-pack-for-2-3kva-extended-runtime-model-72v\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Schneider Electric product page for the SRV72BP-9A external battery pack\u003c\/a\u003e supplied with this UPS — Singapore regional page.\u003c\/p\u003e\n\u003cp\u003eSchneider serves its APC datasheet PDFs from a redirecting download host that regularly returns the wrong model's document, so we do not publish direct PDF links that we cannot verify resolve to the right part number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with the model you need and we will send the correct current-revision datasheet and user manual, along with a GST-invoiced quotation.\u003c\/p\u003e\n\u003cp\u003eEvery specification on this page was taken from Schneider Electric's own product page and its published product datasheet or user manual for this exact part number. Where Schneider's own sources disagreed, or published nothing, the field has been left out rather than estimated.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRVPM3KIL\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 3000 VA and 2400 W ratings, and how do I size it?\u003c\/h4\u003e\n\u003cp\u003eVA is apparent power, watts is real power. The SRVPM3KIL is rated 3000 VA \/ 2400 W, an output power factor of 0.8. Add up the watts of everything you intend to protect, keep the total under 2400 W, and leave headroom — loading a UPS to 100 % shortens both runtime and battery life. As a rough Singapore rule of thumb, a 1U rack server draws 200–400 W, a 24-port PoE switch 150–400 W depending on how much PoE is actually drawn, and a small NAS 60–120 W. Send us the list and we will size it.\u003c\/p\u003e\n\u003ch4\u003eHow long will the SRVPM3KIL run my equipment?\u003c\/h4\u003e\n\u003cp\u003eSchneider does not publish a runtime-at-load table for this model that we could verify against two independent official sources, so we do not quote minutes here rather than invent them.\u003c\/p\u003e\n\u003cp\u003eWhat matters in practice is that autonomy on this build is set by how many \u003cstrong\u003eSRV72BP-9A\u003c\/strong\u003e packs you fit, not by anything inside the UPS — up to 4 can be connected. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with your load in watts and the autonomy you want and we will work out the pack count.\u003c\/p\u003e\n\u003ch4\u003eIs the output a true sine wave, and will it work with an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eYes. Schneider's datasheet for this exact model states a \u003cstrong\u003esine wave\u003c\/strong\u003e output with 3 % voltage distortion, and the topology is \u003cstrong\u003edouble conversion on-line\u003c\/strong\u003e — the load is fed from the inverter continuously rather than being switched over when mains fails. That is what an active-PFC server or workstation PSU wants; the step-approximated output of a low-cost standby UPS is what causes those supplies to trip. Schneider does not publish a numeric transfer time for this model and we do not claim one.\u003c\/p\u003e\n\u003ch4\u003eWhat does the “PM” in SRVPM3KIL mean, and does it come with batteries?\u003c\/h4\u003e\n\u003cp\u003ePM stands for \u003cstrong\u003epower module\u003c\/strong\u003e. Schneider's product name for it ends in “Extended runtime, No Battery” and the user manual confirms these units contain no internal batteries at all — they will not operate until an external battery pack is connected. \u003cstrong\u003eThis SourceIT listing is a complete working system\u003c\/strong\u003e: the SRVPM3KIL power module supplied together with one SRV72BP-9A battery pack (72 V DC). Up to 4 packs can be connected. Schneider also markets the same combination under the bundle designation SRV3KIL.\u003c\/p\u003e\n\u003ch4\u003eCan I add more battery packs later?\u003c\/h4\u003e\n\u003cp\u003eYes — up to \u003cstrong\u003e4 SRV72BP-9A packs\u003c\/strong\u003e can be connected to this power module. The batteries are the pack's, so autonomy scales with pack count rather than with anything inside the UPS. Schneider publishes no verified runtime matrix for these combinations, so rather than quote numbers we will size it against your measured load. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch4\u003eCan the SRVPM3KIL be rack mounted?\u003c\/h4\u003e\n\u003cp\u003eNo. This is a tower unit at 336 mm (H) × 190 mm (W) × 425 mm (D). Schneider builds the rackmount version as a separate part number — the SRVPM…KRIL rackmount extended-runtime series, which we can quote on request. The two are not convertible, and their outlet counts and dimensions differ, so pick the form factor at the point of order.\u003c\/p\u003e\n\u003ch4\u003eHow do I monitor it over the network?\u003c\/h4\u003e\n\u003cp\u003eFit the \u003cstrong\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601\"\u003eAPV9601 SNMP card\u003c\/a\u003e\u003c\/strong\u003e in the UPS Intelligent Card Slot. That is the Easy UPS On-Line card — the AP9640 and AP9641 Network Management Card 3 units fit Smart-UPS SmartSlot equipment and will not work here. Without a card you still get USB and RS-232 for a direct shutdown link to one host, with PowerChute Serial Shutdown or PowerChute Business Edition. Note that Schneider has discontinued the APV9601; ask us about current stock and the AP9544 successor before you commit to a monitoring design.\u003c\/p\u003e\n\u003ch4\u003eIs the SRVPM3KIL covered by warranty in Singapore?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC SRVPM3KIL sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRVPM3KIL with a 2-year manufacturer warranty. Schneider publishes a single worldwide figure of “2 years repair or replace” for the Easy UPS On-Line SRV range — there is no separate European and rest-of-world split on this family, so the term above is the one that applies in Singapore.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bzQk-YuLvCM\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039360385188,"sku":"SRVPM3KIL + SRV72BP-9A","price":1685.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-easy-ups-on-line-srv-3000va-230v-with-extended-runtime-battery-pack-srv3kil-504159.jpg?v=1702980109"},{"product_id":"apc-easy-ups-on-line-srv-6000va-rm-230v-with-extended-runtime-battery-srv6kril","title":"APC Easy UPS On-Line 6000VA RM, Ext. Runtime","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Easy UPS On-Line SRV 6kVA\/6kW Rackmount Extended-Runtime UPS with 240V Battery Pack (SRVPM6KRIL + SRV240RLBP-9A) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eDouble-Conversion On-Line Protection for Singapore's 230V\/50Hz Supply\u003c\/h3\u003e\n\u003cp\u003eThe APC Easy UPS On-Line SRVPM6KRIL is a true double-conversion on-line UPS rated at 6000 VA \/ 6000 W. Incoming mains is rectified to DC and rebuilt as a clean sine wave, so the load is fed from the inverter continuously rather than being switched across to battery when something goes wrong. Output voltage is held to within ±1% and distortion to 1% at full linear load.\u003c\/p\u003e\n\u003cp\u003eThat matters in Singapore, where the practical risk is far more often a sag, a brownout or a switching transient during a thunderstorm than a full blackout. The SRVPM6KRIL accepts 176–300 V AC at 100% load and 110–300 V AC at 60% load, so it rides through PUB grid disturbances on mains and keeps the batteries in reserve for genuine outages. Efficiency is better than 94% at rated load, which keeps the heat load on a comms room air-conditioner down.\u003c\/p\u003e\n\u003ch3\u003eHardwired 3-Wire Installation — Please Plan For This\u003c\/h3\u003e\n\u003cp\u003eThis is a hardwired unit. Schneider's own product name for it reads “Hard wire 3-wire(1P+N+E) outlet”: both the input and the output are terminal blocks. There is \u003cstrong\u003eno plug and there are no IEC C13 or C19 sockets on this model\u003c\/strong\u003e. Anything you want to protect is connected through a downstream rack PDU or distribution board, not plugged into the back of the UPS.\u003c\/p\u003e\n\u003cp\u003eInstallation therefore needs a licensed electrician and a dedicated supply. A 6 kVA load draws in the order of 26 A at 230 V, so the circuit, breaker and cabling have to be sized for it before delivery day. If you were expecting to plug servers straight into the UPS, the IEC-outlet models in the same family are the 1–3 kVA Easy UPS On-Line SRV range — we are happy to help you choose.\u003c\/p\u003e\n\u003ch3\u003eExtended Runtime by Design — 240 V Battery Packs, Not Internal Cells\u003c\/h3\u003e\n\u003cp\u003eThis listing is a two-part system: the SRVPM6KRIL power module and one SRV240RLBP-9A battery pack. The power module carries \u003cstrong\u003eno internal batteries at all\u003c\/strong\u003e — Schneider's own product name for it ends “Extended runtime, No battery”. Every minute of stored energy lives in the external pack, which is what lets this configuration scale far beyond a standard-runtime UPS.\u003c\/p\u003e\n\u003cp\u003eThe pack supplied is a rackmount, 3u chassis holding 2160 VAh on a 240 V DC bus, and up to four packs can be fitted to one UPS. Add packs later as the load or the required hold-up time grows, without replacing the UPS itself. The 1170 W charger brings one pack back to 90% charge in around five hours; each additional pack extends that, and the charge current is configurable at 1, 2, 3 or 4 A so a large bank can be recharged without overloading the supply.\u003c\/p\u003e\n\u003ch3\u003eRack Space and Depth — Check Before You Order\u003c\/h3\u003e\n\u003cp\u003eThe power module is 2U and the battery pack is 3U, so budget \u003cstrong\u003e5U\u003c\/strong\u003e for the system as delivered, plus 3U for every additional pack. The battery pack includes its rack mounting kit; note that Schneider's name for the SRVPM6KRIL power module ends “W\/O rail kit”, so plan the module's mounting with us at quotation stage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDepth matters here.\u003c\/strong\u003e The power module is 615 mm deep and the battery pack 606 mm, so neither fits a standard 600 mm comms cabinet. A 700–900 mm deep rack is the realistic requirement, and the pack weighs 63 kg, so check the cabinet's static load rating and plan to fit it low in the rack.\u003c\/p\u003e\n\u003ch3\u003eFull Nameplate Watts, Bypass, EPO and Network Management\u003c\/h3\u003e\n\u003cp\u003eThe SRVPM6KRIL is rated at unity power factor — 6000 VA gives a full 6000 W with no derating, and efficiency is better than 94% at rated load. An internal bypass operates automatically on overload or fault and can be commanded manually from the LCD console.\u003c\/p\u003e\n\u003cp\u003eA rear-panel Emergency Power Off connector accepts a normally-closed contact for a room EPO loop. The Intelligent Card Slot takes an AP9544 Network Management Card 3 for SNMP monitoring, alerting and network shutdown, with USB and RS-232 ports fitted as standard.\u003c\/p\u003e\n\u003ch3\u003eSupplied Locally, with GST Invoice and Singapore Warranty\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the SRVPM6KRIL as an APC by Schneider Electric product with a full GST invoice and local Singapore warranty support. APC's manufacturer term for this range is two years, repair or replace, and it applies worldwide — there is no separate European figure to catch you out. Schneider ask that the product be registered within ten days of purchase.\u003c\/p\u003e\n\u003cp\u003eBecause this is a hardwired unit, we would rather talk through the supply arrangement, the cabinet depth and the downstream distribution before you commit to a part number. Email sales@sourceit.com.sg with your load list and we will size it properly.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRVPM6KRIL Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral — SRVPM6KRIL Power Module\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line, 6kVA\/6kW, Rackmount 2U, 230V, 1x Hard wire 3-wire(1P+N+E) outlet, Intelligent Slot, Extended runtime, No battery, W\/O rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRVPM6KRIL + SRV240RLBP-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eRackmount, 2U power module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBundle Composition\u003c\/td\u003e\n\u003ctd\u003eSRVPM6KRIL power module supplied together with one SRV240RLBP-9A battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eIncluded with every unit supplied by SourceIT, together with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eOutput — SRVPM6KRIL\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e6000 VA \/ 6000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Factor\u003c\/td\u003e\n\u003ctd\u003eUnity (1.0) — the watt rating equals the VA rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V, configurable to 220 V \/ 230 V \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (on battery)\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±1% static\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Distortion\u003c\/td\u003e\n\u003ctd\u003e1% max at full linear load; 4% max at full non-linear (RCD) load; 15% for the last 60 seconds of backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Crest Factor\u003c\/td\u003e\n\u003ctd\u003e3:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eGreater than 94% at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connection\u003c\/td\u003e\n\u003ctd\u003e1 x hard wire 3-wire (1P+N+E) terminal block — no IEC receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bypass\u003c\/td\u003e\n\u003ctd\u003eAutomatic and manual; bypass range 185–250 V AC ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this model — the load is fed continuously from the inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInput — SRVPM6KRIL\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (100% load)\u003c\/td\u003e\n\u003ctd\u003e176–300 V AC ±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (60% load)\u003c\/td\u003e\n\u003ctd\u003e110–300 V AC ±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Factor\u003c\/td\u003e\n\u003ctd\u003e0.99 or better at 100% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003e1 x hard wire 3-wire (1P+N+E) — hardwired, no inlet plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Protection\u003c\/td\u003e\n\u003ctd\u003eThermal circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e600 joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBatteries \u0026amp; Runtime\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Configuration\u003c\/td\u003e\n\u003ctd\u003eThe SRVPM6KRIL power module carries no internal batteries — Schneider's own product name for it ends “Extended runtime, No battery”. All stored energy is in the external pack(s).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Bus Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed maintenance-free VRLA (valve-regulated lead-acid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Pack Supplied\u003c\/td\u003e\n\u003ctd\u003e1 x SRV240RLBP-9A (240 V DC, 2160 VAh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Battery Packs\u003c\/td\u003e\n\u003ctd\u003eUp to 4 packs per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharger Power\u003c\/td\u003e\n\u003ctd\u003e1170 W rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 5 hours to 90% charge with one battery pack; each additional pack extends the recharge time. Charge current is configurable at 1 A, 2 A, 3 A or 4 A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Load\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this configuration — runtime depends on the load and the number of packs fitted; ask us for a sizing calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCommunications \u0026amp; Management\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eUSB port, RS-232 (DB-9) serial port, Intelligent Card Slot, EPO connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes — Emergency Power Off connector on the rear panel (normally-closed contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Panel\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eOptional AP9544 Network Management Card 3, fitted in the Intelligent Card Slot. Schneider's network management card compatibility chart covers the SRV 5–20 kVA range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBundled Shutdown Software\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for the 6\/10 kVA range — use the network management card for monitoring and shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Card Fitting Note\u003c\/td\u003e\n\u003ctd\u003eFor the SRVPM6KRIL, Schneider notes that an alternate mounting bracket is supplied in the box with the AP9544 card and must be fitted to the card before it is inserted into the slot.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental — SRVPM6KRIL\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e2U for the power module; 5U in total once the 3U battery pack is racked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e86.5 x 438 x 615 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaged Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e240 x 600 x 760 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e1172 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e55 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight Source Note\u003c\/td\u003e\n\u003ctd\u003eThe power module net and shipping weights are printed only in Schneider user manual 990-91615 and are not corroborated by a second document, so treat them as approximate for freight purposes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–40 °C at rated load; 40–45 °C derated linearly to 85% load; 45–50 °C derated linearly to 75% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−15 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e0–95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0–1000 m at full output; 1000–3000 m output derates 1% per 100 m; the UPS will not operate above 3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection \u0026amp; Installation Class\u003c\/td\u003e\n\u003ctd\u003eIP20, pollution degree 2, overvoltage category II, TN power system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, EAC, TISI; EN\/IEC 62040-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eUSB cable, RS-232 serial cable, user documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBattery Pack — SRV240RLBP-9A\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV Battery Pack (6\/10kVA) for Extended Runtime Model 240V, 2160VAh, rackmount with kit, 3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eSRV240RLBP-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Bus Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e2160 VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Blocks\u003c\/td\u003e\n\u003ctd\u003e20 x 12 V 9 Ah sealed maintenance-free VRLA blocks per string\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eRackmount, 3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e133 x 438 x 606 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e250 x 870 x 580 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e63 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Quantity\u003c\/td\u003e\n\u003ctd\u003eUp to 4 packs per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003e5 kVA \/ 6 kVA \/ 10 kVA Easy UPS On-Line SRV extended-runtime models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e0–40 °C, 0–95% RH non-condensing, 0–3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, EAC, EN\/IEC 62040-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eUser manual, battery cable, rack mounting brackets (mounting kit included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Cartridge Part Number\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat Connects to This UPS\u003c\/h3\u003e\n\u003cp\u003eThere are no IEC sockets on this model. Schneider's product name specifies a single hard-wire 3-wire (1P+N+E) output, which is a terminal block. In practice the UPS output feeds a rack PDU, a sub-distribution board or a dedicated final circuit, and your equipment plugs into that. The input is a matching hard-wire 3-wire terminal block, so there is no plug to fit into a wall socket. Both ends must be terminated by a licensed electrician.\u003c\/p\u003e\n\u003cp\u003eSizing guidance: this unit is rated at unity power factor, so its 6000 W rating is the real continuous watts available. A 6000 W load draws in the order of 26 A at 230 V on the output side, and the supply circuit, breaker and cabling need to be sized accordingly, with headroom for battery recharge current on top of the load.\u003c\/p\u003e\n\u003ch3\u003eBattery Packs and Scaling Runtime\u003c\/h3\u003e\n\u003cp\u003eThe SRVPM6KRIL power module holds no batteries. It is supplied here with one SRV240RLBP-9A pack (240 V DC, 2160 VAh) and accepts \u003cstrong\u003eup to four packs\u003c\/strong\u003e in total, so runtime can be extended later without changing the UPS. The packs run on a 240 V DC bus and are built from 20 x 12 V 9 Ah sealed VRLA blocks per string.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo not cross-order packs between ranges.\u003c\/strong\u003e The 192 V battery modules used by the standard-runtime SRV6KRIRK and SRV10KRIRK (SRV192RBP-7A \/ SRV192RBP-9A) are a different bus voltage and are not interchangeable with these 240 V packs. Schneider does not publish a replacement cartridge part number for the packs themselves, and makes no hot-swap claim for them, so we do not make one either.\u003c\/p\u003e\n\u003ch3\u003eRack Fit, Depth and Weight\u003c\/h3\u003e\n\u003cp\u003eBudget \u003cstrong\u003e5U\u003c\/strong\u003e for the delivered system: 2U for the power module and 3U for the battery pack, plus a further 3U for each additional pack. The power module is 615 mm deep and the pack 606 mm, so a standard 600 mm cabinet will not take either — plan on 700–900 mm. The pack weighs 63 kg, so mount it low and check the cabinet's static load rating.\u003c\/p\u003e\n\u003cp\u003eThe battery pack includes its rack mounting kit. Schneider's name for the power module ends “W\/O rail kit”, so please confirm the module's mounting hardware with us at quotation stage rather than assuming rails are in the box.\u003c\/p\u003e\n\u003ch3\u003eRuntime\u003c\/h3\u003e\n\u003cp\u003eSchneider publishes no runtime figures for this configuration, so we do not print any. Runtime depends on the load and on how many packs are fitted. Tell us the load in watts and the hold-up time you need and we will calculate the pack count with the distributor.\u003c\/p\u003e\n\u003ch3\u003eManagement and Software\u003c\/h3\u003e\n\u003cp\u003eThe Intelligent Card Slot accepts an AP9544 Network Management Card 3; Schneider's card compatibility chart covers the SRV 5–20 kVA range. USB and RS-232 serial ports are fitted as standard, and a rear-panel EPO connector takes a normally-closed contact for a room emergency power off loop.\u003c\/p\u003e\n\u003cp\u003eNote for this part number specifically: Schneider records that an alternate mounting bracket is supplied in the box with the AP9544 card and must be fitted to the card before it is inserted into the SRVPM6KRIL.\u003c\/p\u003e\n\u003cp\u003eSchneider does not document a bundled shutdown software package for the 6 and 10 kVA models, so we do not advertise one — network monitoring and shutdown are provided by the management card. The APV9601 card listed in our catalogue is documented for the smaller Easy UPS On-Line SRV models and should not be ordered for this unit.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cp\u003eUSB cable, RS-232 serial cable, user documentation\u003c\/p\u003e\n\u003cp\u003eSupplied with it: 1 x SRV240RLBP-9A battery pack — User manual, battery cable, rack mounting brackets (mounting kit included).\u003c\/p\u003e\n\u003ch3\u003eEasy UPS On-Line SRV 6–10 kVA Ordering Information\u003c\/h3\u003e\n\u003cp\u003eEvery model below is hardwired at both input and output. Choose by rating first, then by form factor, then by whether you need standard or extended runtime.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-6000va-230v-srv6ki\"\u003eSRV6KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kVA \/ 6 kW\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003ctd\u003eInternal battery, standard runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-10000va-230v-srv10ki\"\u003eSRV10KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA \/ 10 kW\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003ctd\u003eInternal battery, standard runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-6000va-230v-with-railkit-external-battery-pack-srv6krirk\"\u003eSRV6KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kVA \/ 6 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 4U, rail kit\u003c\/td\u003e\n\u003ctd\u003e192 V battery module included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-railkit-external-battery-pack-srv10krirk\"\u003eSRV10KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA \/ 10 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 4U, rail kit\u003c\/td\u003e\n\u003ctd\u003e192 V battery module included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSRVPM6KRIL + SRV240RLBP-9A (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kVA \/ 6 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U + 3U pack\u003c\/td\u003e\n\u003ctd\u003e240 V pack, extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-10000va-230v-with-extended-runtime-battery-pack-srv10kil\"\u003eSRVPM10KIL + SRV240BP-9A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA \/ 10 kW\u003c\/td\u003e\n\u003ctd\u003eTower + tower pack\u003c\/td\u003e\n\u003ctd\u003e240 V pack, extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-external-battery-pack-srv10krirk\"\u003eSRVPM10KRIL + SRV240RLBP-9A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA \/ 10 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U + 3U pack\u003c\/td\u003e\n\u003ctd\u003e240 V pack, extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories and Replacement Batteries\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV192RBP-7A\u003c\/td\u003e\n\u003ctd\u003eReplacement 192 V battery module for the SRV6KRIRK. Not currently stocked — email sales@sourceit.com.sg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV192RBP-9A\u003c\/td\u003e\n\u003ctd\u003eReplacement 192 V battery module for the SRV10KRIRK. Not currently stocked — email sales@sourceit.com.sg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV240BP-9A\u003c\/td\u003e\n\u003ctd\u003e240 V 2160 VAh tower battery pack for the extended-runtime tower models, up to 4 per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV240RLBP-9A\u003c\/td\u003e\n\u003ctd\u003e240 V 2160 VAh 3U rackmount battery pack with mounting kit, for the extended-runtime rack models, up to 4 per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9544\u003c\/td\u003e\n\u003ctd\u003eNetwork Management Card 3 for the Intelligent Card Slot, per Schneider's card compatibility chart for SRV 5–20 kVA. Not currently stocked — email sales@sourceit.com.sg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVRK1 \/ SRVRK2\u003c\/td\u003e\n\u003ctd\u003eRail kits named by Schneider as optional accessories for the base SRV6KRI \/ SRV10KRI. SRVRK2 is the 900 mm depth kit for the battery module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eSmaller Ratings in the Same Family\u003c\/h3\u003e\n\u003cp\u003eIf 6 kVA is more than you need, the 1–3 kVA Easy UPS On-Line SRV models use IEC outlets and a standard plug, so they need no electrician.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-230v-srv1ki\"\u003eSRV1KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kVA \/ 800 W\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-srv2ki\"\u003eSRV2KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kVA \/ 1600 W\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-srv3ki\"\u003eSRV3KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kVA \/ 2400 W\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri\"\u003eSRV1KRI + SRVRK1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kVA \/ 800 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri\"\u003eSRV2KRI + SRVRK1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kVA \/ 1600 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri\"\u003eSRV3KRI + SRVRK1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kVA \/ 2400 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eSchneider Electric hosts the official documentation for this product. The link below is the product page we verified resolves and shows the correct part number.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric product page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/il\/en\/product\/SRVPM6KRIL\/apc-easy-ups-online-srv-rm-extended-runtime-6000va-230v-no-battery\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC SRVPM6KRIL on se.com\u003c\/a\u003e — Israel (no Singapore page is published for this part number) site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery pack product page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/eg\/en\/product\/SRV240RLBP-9A\/apc-easy-ups-online-srv-battery-pack-6-10kva-for-extended-runtime-model-240v-2160vah-rackmount-with-kit-3u\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC SRV240RLBP-9A on se.com\u003c\/a\u003e — Egypt site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eSRVPM6KRIL\u003c\/strong\u003e and we will send you the current PDF datasheet and user manual directly.\u003c\/p\u003e\n\u003cp\u003eThe governing document for this model is Schneider user manual 990-91615, which covers the SRV5KRIL, SRV6KRIL, SRV10KRIL, SRV6KIL and SRV10KIL extended-runtime models.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRVPM6KRIL\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat is the difference between the VA and the watt rating, and how do I size this UPS?\u003c\/h3\u003e\n\u003cp\u003eVA is apparent power and watts is real power. On most UPS ranges the watt figure is lower than the VA figure, so the watt rating is the one that limits what you can connect. This model is unusual and welcome in that it is rated at unity power factor: 6000 VA gives a full 6000 W. Add up the continuous watts of everything you intend to protect, leave headroom for start-up surge and for future growth, and check the total against 6000 W. Send us the list and we will do it with you.\u003c\/p\u003e\n\u003ch3\u003eDoes this model have IEC outlets I can plug servers into?\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider's product name specifies a hard-wire 3-wire (1P+N+E) output, which is a terminal block. There are no C13 or C19 sockets on the unit at all, and the input is hardwired too. The output feeds a rack PDU or a distribution board, and a licensed electrician must terminate both ends. If you need a UPS you can simply plug into, look at the 1–3 kVA Easy UPS On-Line SRV models instead.\u003c\/p\u003e\n\u003ch3\u003eWhat runtime will I get?\u003c\/h3\u003e\n\u003cp\u003eSchneider does not publish a runtime table for this model, and we will not print a figure we cannot source. Runtime depends on how heavily the UPS is loaded — a unit at 30 per cent load runs far longer than the same unit at 90 per cent. Email sales@sourceit.com.sg with your load in watts and the hold-up time you need and we will get a proper figure from the distributor.\u003c\/p\u003e\n\u003ch3\u003eWhat does the “PM” in SRVPM6KRIL mean, and where are the batteries?\u003c\/h3\u003e\n\u003cp\u003ePM stands for power module. Schneider's official name for this part ends “Extended runtime, No battery”: the module itself contains no batteries at all. All the stored energy is in the external SRV240RLBP-9A pack supplied with it, and up to four packs can be fitted to one UPS. That is precisely why this configuration can be scaled to long runtimes that a standard-runtime UPS cannot reach.\u003c\/p\u003e\n\u003ch3\u003eCan I use the battery packs from the standard-runtime SRV6KRIRK or SRV10KRIRK?\u003c\/h3\u003e\n\u003cp\u003eNo, and this is worth being careful about. The standard-runtime rack models run a 192 V DC battery bus and use a complete replacement battery module (SRV192RBP-7A or SRV192RBP-9A). The extended-runtime models on this page run a 240 V DC bus and use the SRV240BP-9A or SRV240RLBP-9A packs. The two are not interchangeable in either direction.\u003c\/p\u003e\n\u003ch3\u003eHow much rack space does it need, and will it fit my cabinet?\u003c\/h3\u003e\n\u003cp\u003eThe delivered system occupies 5U (2U power module plus a 3U battery pack). Depth is the thing to check: at 615 mm the chassis will not fit a standard 600 mm comms cabinet, so plan on a deeper rack, typically 800–900 mm, with rear clearance for the hardwired conduit. Please measure before you order — depth is the most common cause of an avoidable return on a unit this size.\u003c\/p\u003e\n\u003ch3\u003eHow do I monitor it over the network?\u003c\/h3\u003e\n\u003cp\u003eThe Intelligent Card Slot takes an AP9544 Network Management Card 3, which Schneider's compatibility chart covers for the SRV 5–20 kVA range. That gives SNMP monitoring, alerting and network shutdown. USB and RS-232 ports are fitted as standard. Schneider does not document a bundled shutdown software package for the 6 and 10 kVA models, so please do not assume PowerChute over USB — ask us and we will confirm what is supported for your build. The APV9601 card in our catalogue is for the smaller Easy UPS On-Line SRV models and should not be ordered for this one.\u003c\/p\u003e\n\u003ch3\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC SRVPM6KRIL sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRVPM6KRIL with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bzQk-YuLvCM\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039373459620,"sku":"SRVPM6KRIL + SRV240RLBP-9A","price":3745.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-easy-ups-on-line-srv-6000va-rm-230v-with-extended-runtime-battery-pack-srv6kril-603981.jpg?v=1671740217"},{"product_id":"apc-easy-ups-on-line-srv-10000va-230v-with-extended-runtime-battery-pack-srv10kil","title":"APC Easy UPS On-Line 10000VA, Ext. Runtime","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Easy UPS On-Line SRV 10kVA\/10kW Tower Extended-Runtime UPS with 240V Battery Pack (SRVPM10KIL + SRV240BP-9A) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eDouble-Conversion On-Line Protection for Singapore's 230V\/50Hz Supply\u003c\/h3\u003e\n\u003cp\u003eThe APC Easy UPS On-Line SRVPM10KIL is a true double-conversion on-line UPS rated at 10000 VA \/ 10000 W. Incoming mains is rectified to DC and rebuilt as a clean sine wave, so the load is fed from the inverter continuously rather than being switched across to battery when something goes wrong. Output voltage is held to within ±1% and distortion to 1% at full linear load.\u003c\/p\u003e\n\u003cp\u003eThat matters in Singapore, where the practical risk is far more often a sag, a brownout or a switching transient during a thunderstorm than a full blackout. The SRVPM10KIL accepts 176–300 V AC at 100% load and 110–300 V AC at 60% load, so it rides through PUB grid disturbances on mains and keeps the batteries in reserve for genuine outages. Efficiency is better than 94% at rated load, which keeps the heat load on a comms room air-conditioner down.\u003c\/p\u003e\n\u003ch3\u003eHardwired 3-Wire Installation — Please Plan For This\u003c\/h3\u003e\n\u003cp\u003eThis is a hardwired unit. Schneider's own product name for it reads “Hard wire 3-wire(1P+N+E) outlet”: both the input and the output are terminal blocks. There is \u003cstrong\u003eno plug and there are no IEC C13 or C19 sockets on this model\u003c\/strong\u003e. Anything you want to protect is connected through a downstream rack PDU or distribution board, not plugged into the back of the UPS.\u003c\/p\u003e\n\u003cp\u003eInstallation therefore needs a licensed electrician and a dedicated supply. A 10 kVA load draws in the order of 44 A at 230 V, so the circuit, breaker and cabling have to be sized for it before delivery day. If you were expecting to plug servers straight into the UPS, the IEC-outlet models in the same family are the 1–3 kVA Easy UPS On-Line SRV range — we are happy to help you choose.\u003c\/p\u003e\n\u003ch3\u003eExtended Runtime by Design — 240 V Battery Packs, Not Internal Cells\u003c\/h3\u003e\n\u003cp\u003eThis listing is a two-part system: the SRVPM10KIL power module and one SRV240BP-9A battery pack. The power module carries \u003cstrong\u003eno internal batteries at all\u003c\/strong\u003e — Schneider's own product name for it ends “Extended runtime, No battery”. Every minute of stored energy lives in the external pack, which is what lets this configuration scale far beyond a standard-runtime UPS.\u003c\/p\u003e\n\u003cp\u003eThe pack supplied is a tower chassis holding 2160 VAh on a 240 V DC bus, and up to four packs can be fitted to one UPS. Add packs later as the load or the required hold-up time grows, without replacing the UPS itself. The 1170 W charger brings one pack back to 90% charge in around five hours; each additional pack extends that, and the charge current is configurable at 1, 2, 3 or 4 A so a large bank can be recharged without overloading the supply.\u003c\/p\u003e\n\u003ch3\u003eTower Footprint and Weight\u003c\/h3\u003e\n\u003cp\u003eThe power module is a compact 336 x 190 x 447 mm tower at 16.5 kg. The SRV240BP-9A battery pack beside it is 368 x 190 x 485 mm and 60 kg, and Schneider publishes a combined system net weight of 76.5 kg for the equivalent bundle. Both are 190 mm wide, so the pair stands side by side in roughly 380 mm of floor width.\u003c\/p\u003e\n\u003cp\u003eThat weight is worth planning for: a raised floor, a lift and a two-person delivery are all sensible assumptions, and every additional pack adds another 60 kg.\u003c\/p\u003e\n\u003ch3\u003eFull Nameplate Watts, Bypass, EPO and Network Management\u003c\/h3\u003e\n\u003cp\u003eThe SRVPM10KIL is rated at unity power factor — 10000 VA gives a full 10000 W with no derating, and efficiency is better than 94% at rated load. An internal bypass operates automatically on overload or fault and can be commanded manually from the LCD console.\u003c\/p\u003e\n\u003cp\u003eA rear-panel Emergency Power Off connector accepts a normally-closed contact for a room EPO loop. The Intelligent Card Slot takes an AP9544 Network Management Card 3 for SNMP monitoring, alerting and network shutdown, with USB and RS-232 ports fitted as standard.\u003c\/p\u003e\n\u003ch3\u003eSupplied Locally, with GST Invoice and Singapore Warranty\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the SRVPM10KIL as an APC by Schneider Electric product with a full GST invoice and local Singapore warranty support. APC's manufacturer term for this range is two years, repair or replace, and it applies worldwide — there is no separate European figure to catch you out. Schneider ask that the product be registered within ten days of purchase.\u003c\/p\u003e\n\u003cp\u003eBecause this is a hardwired unit, we would rather talk through the supply arrangement and the downstream distribution before you commit to a part number. Email sales@sourceit.com.sg with your load list and we will size it properly.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRVPM10KIL Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral — SRVPM10KIL Power Module\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line, 10kVA\/10kW, Tower, 230V, 1x Hard wire 3-wire(1P+N+E) outlet, Intelligent Card Slot, LCD, Extended runtime, No battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRVPM10KIL + SRV240BP-9A (Tower)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower power module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBundle Composition\u003c\/td\u003e\n\u003ctd\u003eSRVPM10KIL power module supplied together with one SRV240BP-9A battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eIncluded with every unit supplied by SourceIT, together with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eOutput — SRVPM10KIL\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e10000 VA \/ 10000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Factor\u003c\/td\u003e\n\u003ctd\u003eUnity (1.0) — the watt rating equals the VA rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V, configurable to 220 V \/ 230 V \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (on battery)\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±1% static\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Distortion\u003c\/td\u003e\n\u003ctd\u003e1% max at full linear load; 4% max at full non-linear (RCD) load; 15% for the last 60 seconds of backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Crest Factor\u003c\/td\u003e\n\u003ctd\u003e3:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eGreater than 94% at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connection\u003c\/td\u003e\n\u003ctd\u003e1 x hard wire 3-wire (1P+N+E) terminal block — no IEC receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bypass\u003c\/td\u003e\n\u003ctd\u003eAutomatic and manual; bypass range 185–250 V AC ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this model — the load is fed continuously from the inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInput — SRVPM10KIL\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (100% load)\u003c\/td\u003e\n\u003ctd\u003e176–300 V AC ±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (60% load)\u003c\/td\u003e\n\u003ctd\u003e110–300 V AC ±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Factor\u003c\/td\u003e\n\u003ctd\u003e0.99 or better at 100% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003e1 x hard wire 3-wire (1P+N+E) — hardwired, no inlet plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Protection\u003c\/td\u003e\n\u003ctd\u003eThermal circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e600 joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBatteries \u0026amp; Runtime\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Configuration\u003c\/td\u003e\n\u003ctd\u003eThe SRVPM10KIL power module carries no internal batteries — Schneider's own product name for it ends “Extended runtime, No battery”. All stored energy is in the external pack(s).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Bus Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed maintenance-free VRLA (valve-regulated lead-acid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Pack Supplied\u003c\/td\u003e\n\u003ctd\u003e1 x SRV240BP-9A (240 V DC, 2160 VAh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Battery Packs\u003c\/td\u003e\n\u003ctd\u003eUp to 4 packs per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharger Power\u003c\/td\u003e\n\u003ctd\u003e1170 W rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 5 hours to 90% charge with one battery pack; each additional pack extends the recharge time. Charge current is configurable at 1 A, 2 A, 3 A or 4 A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Load\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this configuration — runtime depends on the load and the number of packs fitted; ask us for a sizing calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCommunications \u0026amp; Management\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eUSB port, RS-232 (DB-9) serial port, Intelligent Card Slot, EPO connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes — Emergency Power Off connector on the rear panel (normally-closed contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Panel\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eOptional AP9544 Network Management Card 3, fitted in the Intelligent Card Slot. Schneider's network management card compatibility chart covers the SRV 5–20 kVA range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBundled Shutdown Software\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for the 6\/10 kVA range — use the network management card for monitoring and shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental — SRVPM10KIL\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e336 x 190 x 447 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaged Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e460 x 290 x 570 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e16.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e19.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e2128 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e58 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight Source Note\u003c\/td\u003e\n\u003ctd\u003eSchneider publishes a combined system net weight of 76.5 kg for the equivalent SRV10KIL bundle, which reconciles with the 16.5 kg module plus the 60 kg battery pack.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–40 °C at rated load; 40–45 °C derated linearly to 85% load; 45–50 °C derated linearly to 75% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−15 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e0–95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0–1000 m at full output; 1000–3000 m output derates 1% per 100 m; the UPS will not operate above 3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection \u0026amp; Installation Class\u003c\/td\u003e\n\u003ctd\u003eIP20, pollution degree 2, overvoltage category II, TN power system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, EAC, TISI; EN\/IEC 62040-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eUSB cable, RS-232 serial cable, user documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBattery Pack — SRV240BP-9A\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV Battery Pack for 6\/10kVA Extended runtime model, 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eSRV240BP-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Bus Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e2160 VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Blocks\u003c\/td\u003e\n\u003ctd\u003e20 x 12 V 9 Ah sealed maintenance-free VRLA blocks per string\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e368 x 190 x 485 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e460 x 570 x 290 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e63 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Quantity\u003c\/td\u003e\n\u003ctd\u003eUp to 4 packs per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003e6 kVA \/ 10 kVA Easy UPS On-Line SRV extended-runtime models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e0–40 °C, 0–95% RH non-condensing, 0–3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, EAC, EN\/IEC 62040-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eUser manual, battery cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Cartridge Part Number\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat Connects to This UPS\u003c\/h3\u003e\n\u003cp\u003eThere are no IEC sockets on this model. Schneider's product name specifies a single hard-wire 3-wire (1P+N+E) output, which is a terminal block. In practice the UPS output feeds a rack PDU, a sub-distribution board or a dedicated final circuit, and your equipment plugs into that. The input is a matching hard-wire 3-wire terminal block, so there is no plug to fit into a wall socket. Both ends must be terminated by a licensed electrician.\u003c\/p\u003e\n\u003cp\u003eSizing guidance: this unit is rated at unity power factor, so its 10000 W rating is the real continuous watts available. A 10000 W load draws in the order of 44 A at 230 V on the output side, and the supply circuit, breaker and cabling need to be sized accordingly, with headroom for battery recharge current on top of the load.\u003c\/p\u003e\n\u003ch3\u003eBattery Packs and Scaling Runtime\u003c\/h3\u003e\n\u003cp\u003eThe SRVPM10KIL power module holds no batteries. It is supplied here with one SRV240BP-9A pack (240 V DC, 2160 VAh) and accepts \u003cstrong\u003eup to four packs\u003c\/strong\u003e in total, so runtime can be extended later without changing the UPS. The packs run on a 240 V DC bus and are built from 20 x 12 V 9 Ah sealed VRLA blocks per string.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo not cross-order packs between ranges.\u003c\/strong\u003e The 192 V battery modules used by the standard-runtime SRV6KRIRK and SRV10KRIRK (SRV192RBP-7A \/ SRV192RBP-9A) are a different bus voltage and are not interchangeable with these 240 V packs. Schneider does not publish a replacement cartridge part number for the packs themselves, and makes no hot-swap claim for them, so we do not make one either.\u003c\/p\u003e\n\u003ch3\u003eSiting and Weight\u003c\/h3\u003e\n\u003cp\u003eBoth the power module and the pack are tower chassis 190 mm wide, standing side by side in roughly 380 mm of floor width. The pack weighs 60 kg on its own and each additional pack adds the same again, so plan delivery and floor loading accordingly.\u003c\/p\u003e\n\u003ch3\u003eRuntime\u003c\/h3\u003e\n\u003cp\u003eSchneider publishes no runtime figures for this configuration, so we do not print any. Runtime depends on the load and on how many packs are fitted. Tell us the load in watts and the hold-up time you need and we will calculate the pack count with the distributor.\u003c\/p\u003e\n\u003ch3\u003eManagement and Software\u003c\/h3\u003e\n\u003cp\u003eThe Intelligent Card Slot accepts an AP9544 Network Management Card 3; Schneider's card compatibility chart covers the SRV 5–20 kVA range. USB and RS-232 serial ports are fitted as standard, and a rear-panel EPO connector takes a normally-closed contact for a room emergency power off loop.\u003c\/p\u003e\n\u003cp\u003eSchneider does not document a bundled shutdown software package for the 6 and 10 kVA models, so we do not advertise one — network monitoring and shutdown are provided by the management card. The APV9601 card listed in our catalogue is documented for the smaller Easy UPS On-Line SRV models and should not be ordered for this unit.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cp\u003eUSB cable, RS-232 serial cable, user documentation\u003c\/p\u003e\n\u003cp\u003eSupplied with it: 1 x SRV240BP-9A battery pack — User manual, battery cable.\u003c\/p\u003e\n\u003ch3\u003eEasy UPS On-Line SRV 6–10 kVA Ordering Information\u003c\/h3\u003e\n\u003cp\u003eEvery model below is hardwired at both input and output. Choose by rating first, then by form factor, then by whether you need standard or extended runtime.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-6000va-230v-srv6ki\"\u003eSRV6KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kVA \/ 6 kW\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003ctd\u003eInternal battery, standard runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-10000va-230v-srv10ki\"\u003eSRV10KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA \/ 10 kW\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003ctd\u003eInternal battery, standard runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-6000va-230v-with-railkit-external-battery-pack-srv6krirk\"\u003eSRV6KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kVA \/ 6 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 4U, rail kit\u003c\/td\u003e\n\u003ctd\u003e192 V battery module included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-railkit-external-battery-pack-srv10krirk\"\u003eSRV10KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA \/ 10 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 4U, rail kit\u003c\/td\u003e\n\u003ctd\u003e192 V battery module included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-6000va-rm-230v-with-extended-runtime-battery-srv6kril\"\u003eSRVPM6KRIL + SRV240RLBP-9A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kVA \/ 6 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U + 3U pack\u003c\/td\u003e\n\u003ctd\u003e240 V pack, extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSRVPM10KIL + SRV240BP-9A (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA \/ 10 kW\u003c\/td\u003e\n\u003ctd\u003eTower + tower pack\u003c\/td\u003e\n\u003ctd\u003e240 V pack, extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-external-battery-pack-srv10krirk\"\u003eSRVPM10KRIL + SRV240RLBP-9A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA \/ 10 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U + 3U pack\u003c\/td\u003e\n\u003ctd\u003e240 V pack, extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories and Replacement Batteries\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV192RBP-7A\u003c\/td\u003e\n\u003ctd\u003eReplacement 192 V battery module for the SRV6KRIRK. Not currently stocked — email sales@sourceit.com.sg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV192RBP-9A\u003c\/td\u003e\n\u003ctd\u003eReplacement 192 V battery module for the SRV10KRIRK. Not currently stocked — email sales@sourceit.com.sg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV240BP-9A\u003c\/td\u003e\n\u003ctd\u003e240 V 2160 VAh tower battery pack for the extended-runtime tower models, up to 4 per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV240RLBP-9A\u003c\/td\u003e\n\u003ctd\u003e240 V 2160 VAh 3U rackmount battery pack with mounting kit, for the extended-runtime rack models, up to 4 per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9544\u003c\/td\u003e\n\u003ctd\u003eNetwork Management Card 3 for the Intelligent Card Slot, per Schneider's card compatibility chart for SRV 5–20 kVA. Not currently stocked — email sales@sourceit.com.sg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVRK1 \/ SRVRK2\u003c\/td\u003e\n\u003ctd\u003eRail kits named by Schneider as optional accessories for the base SRV6KRI \/ SRV10KRI. SRVRK2 is the 900 mm depth kit for the battery module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eSmaller Ratings in the Same Family\u003c\/h3\u003e\n\u003cp\u003eIf 6 kVA is more than you need, the 1–3 kVA Easy UPS On-Line SRV models use IEC outlets and a standard plug, so they need no electrician.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-230v-srv1ki\"\u003eSRV1KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kVA \/ 800 W\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-srv2ki\"\u003eSRV2KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kVA \/ 1600 W\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-srv3ki\"\u003eSRV3KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kVA \/ 2400 W\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri\"\u003eSRV1KRI + SRVRK1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kVA \/ 800 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri\"\u003eSRV2KRI + SRVRK1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kVA \/ 1600 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri\"\u003eSRV3KRI + SRVRK1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kVA \/ 2400 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eSchneider Electric hosts the official documentation for this product. The link below is the product page we verified resolves and shows the correct part number.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric product page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/th\/en\/product\/SRVPM10KIL\/apc-easy-ups-online-10kva-10kw-tower-230v-1x-hard-wire-3wire1p+n+e-outlet-intelligent-card-slot-lcd-extended-runtime-no-battery\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC SRVPM10KIL on se.com\u003c\/a\u003e — Thailand (no Singapore page is published for this part number) site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery pack product page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/eg\/en\/product\/SRV240BP-9A\/apc-easy-ups-online-srv-battery-pack-6-10kva-for-extended-runtime-model-240v-2160vah\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC SRV240BP-9A on se.com\u003c\/a\u003e — Egypt site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eSRVPM10KIL\u003c\/strong\u003e and we will send you the current PDF datasheet and user manual directly.\u003c\/p\u003e\n\u003cp\u003eThe governing document for this model is Schneider user manual 990-91615, which covers the SRV5KRIL, SRV6KRIL, SRV10KRIL, SRV6KIL and SRV10KIL extended-runtime models.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRVPM10KIL\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat is the difference between the VA and the watt rating, and how do I size this UPS?\u003c\/h3\u003e\n\u003cp\u003eVA is apparent power and watts is real power. On most UPS ranges the watt figure is lower than the VA figure, so the watt rating is the one that limits what you can connect. This model is unusual and welcome in that it is rated at unity power factor: 10000 VA gives a full 10000 W. Add up the continuous watts of everything you intend to protect, leave headroom for start-up surge and for future growth, and check the total against 10000 W. Send us the list and we will do it with you.\u003c\/p\u003e\n\u003ch3\u003eDoes this model have IEC outlets I can plug servers into?\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider's product name specifies a hard-wire 3-wire (1P+N+E) output, which is a terminal block. There are no C13 or C19 sockets on the unit at all, and the input is hardwired too. The output feeds a rack PDU or a distribution board, and a licensed electrician must terminate both ends. If you need a UPS you can simply plug into, look at the 1–3 kVA Easy UPS On-Line SRV models instead.\u003c\/p\u003e\n\u003ch3\u003eWhat runtime will I get?\u003c\/h3\u003e\n\u003cp\u003eSchneider does not publish a runtime table for this model, and we will not print a figure we cannot source. Runtime depends on how heavily the UPS is loaded — a unit at 30 per cent load runs far longer than the same unit at 90 per cent. Email sales@sourceit.com.sg with your load in watts and the hold-up time you need and we will get a proper figure from the distributor.\u003c\/p\u003e\n\u003ch3\u003eWhat does the “PM” in SRVPM10KIL mean, and where are the batteries?\u003c\/h3\u003e\n\u003cp\u003ePM stands for power module. Schneider's official name for this part ends “Extended runtime, No battery”: the module itself contains no batteries at all. All the stored energy is in the external SRV240BP-9A pack supplied with it, and up to four packs can be fitted to one UPS. That is precisely why this configuration can be scaled to long runtimes that a standard-runtime UPS cannot reach.\u003c\/p\u003e\n\u003ch3\u003eCan I use the battery packs from the standard-runtime SRV6KRIRK or SRV10KRIRK?\u003c\/h3\u003e\n\u003cp\u003eNo, and this is worth being careful about. The standard-runtime rack models run a 192 V DC battery bus and use a complete replacement battery module (SRV192RBP-7A or SRV192RBP-9A). The extended-runtime models on this page run a 240 V DC bus and use the SRV240BP-9A or SRV240RLBP-9A packs. The two are not interchangeable in either direction.\u003c\/p\u003e\n\u003ch3\u003eCan this tower model be rack mounted?\u003c\/h3\u003e\n\u003cp\u003eSchneider's official name for it says Tower and offers no rail kit, so we do not advertise it as rack-mountable. The rackmount build of the same rating is a separate part number and is listed in the ordering table above.\u003c\/p\u003e\n\u003ch3\u003eHow do I monitor it over the network?\u003c\/h3\u003e\n\u003cp\u003eThe Intelligent Card Slot takes an AP9544 Network Management Card 3, which Schneider's compatibility chart covers for the SRV 5–20 kVA range. That gives SNMP monitoring, alerting and network shutdown. USB and RS-232 ports are fitted as standard. Schneider does not document a bundled shutdown software package for the 6 and 10 kVA models, so please do not assume PowerChute over USB — ask us and we will confirm what is supported for your build. The APV9601 card in our catalogue is for the smaller Easy UPS On-Line SRV models and should not be ordered for this one.\u003c\/p\u003e\n\u003ch3\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC SRVPM10KIL sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRVPM10KIL with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bzQk-YuLvCM\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039384928420,"sku":"SRVPM10KIL + SRV240BP-9A  (Tower)","price":4605.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-easy-ups-on-line-srv-10000va-230v-with-extended-runtime-battery-pack-srv10kil-284189.jpg?v=1671740217"},{"product_id":"apc-easy-ups-srv-rm-10000va-230v-with-external-battery-pack-srv10krirk","title":"APC Easy UPS SRV RM 10000VA 230V, Ext. Battery Pack","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Easy UPS On-Line SRV 10kVA\/10kW Rackmount Extended-Runtime UPS with 240V Battery Pack (SRVPM10KRIL + SRV240RLBP-9A) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eDouble-Conversion On-Line Protection for Singapore's 230V\/50Hz Supply\u003c\/h3\u003e\n\u003cp\u003eThe APC Easy UPS On-Line SRVPM10KRIL is a true double-conversion on-line UPS rated at 10000 VA \/ 10000 W. Incoming mains is rectified to DC and rebuilt as a clean sine wave, so the load is fed from the inverter continuously rather than being switched across to battery when something goes wrong. Output voltage is held to within ±1% and distortion to 1% at full linear load.\u003c\/p\u003e\n\u003cp\u003eThat matters in Singapore, where the practical risk is far more often a sag, a brownout or a switching transient during a thunderstorm than a full blackout. The SRVPM10KRIL accepts 176–300 V AC at 100% load and 110–300 V AC at 60% load, so it rides through PUB grid disturbances on mains and keeps the batteries in reserve for genuine outages. Efficiency is better than 94% at rated load, which keeps the heat load on a comms room air-conditioner down.\u003c\/p\u003e\n\u003ch3\u003eHardwired 3-Wire Installation — Please Plan For This\u003c\/h3\u003e\n\u003cp\u003eThis is a hardwired unit. Schneider's own product name for it reads “Hard wire 3-wire(1P+N+E) outlet”: both the input and the output are terminal blocks. There is \u003cstrong\u003eno plug and there are no IEC C13 or C19 sockets on this model\u003c\/strong\u003e. Anything you want to protect is connected through a downstream rack PDU or distribution board, not plugged into the back of the UPS.\u003c\/p\u003e\n\u003cp\u003eInstallation therefore needs a licensed electrician and a dedicated supply. A 10 kVA load draws in the order of 44 A at 230 V, so the circuit, breaker and cabling have to be sized for it before delivery day. If you were expecting to plug servers straight into the UPS, the IEC-outlet models in the same family are the 1–3 kVA Easy UPS On-Line SRV range — we are happy to help you choose.\u003c\/p\u003e\n\u003ch3\u003eExtended Runtime by Design — 240 V Battery Packs, Not Internal Cells\u003c\/h3\u003e\n\u003cp\u003eThis listing is a two-part system: the SRVPM10KRIL power module and one SRV240RLBP-9A battery pack. The power module carries \u003cstrong\u003eno internal batteries at all\u003c\/strong\u003e — Schneider's own product name for it ends “Extended runtime, No battery”. Every minute of stored energy lives in the external pack, which is what lets this configuration scale far beyond a standard-runtime UPS.\u003c\/p\u003e\n\u003cp\u003eThe pack supplied is a rackmount, 3u chassis holding 2160 VAh on a 240 V DC bus, and up to four packs can be fitted to one UPS. Add packs later as the load or the required hold-up time grows, without replacing the UPS itself. The 1170 W charger brings one pack back to 90% charge in around five hours; each additional pack extends that, and the charge current is configurable at 1, 2, 3 or 4 A so a large bank can be recharged without overloading the supply.\u003c\/p\u003e\n\u003ch3\u003eRack Space and Depth — Check Before You Order\u003c\/h3\u003e\n\u003cp\u003eThe power module is 2U and the battery pack is 3U, so budget \u003cstrong\u003e5U\u003c\/strong\u003e for the system as delivered, plus 3U for every additional pack. The battery pack includes its rack mounting kit; note that Schneider's name for the SRVPM10KRIL power module ends “W\/O rail kit”, so plan the module's mounting with us at quotation stage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDepth matters here.\u003c\/strong\u003e The power module is 615 mm deep and the battery pack 606 mm, so neither fits a standard 600 mm comms cabinet. A 700–900 mm deep rack is the realistic requirement, and the pack weighs 63 kg, so check the cabinet's static load rating and plan to fit it low in the rack.\u003c\/p\u003e\n\u003ch3\u003eFull Nameplate Watts, Bypass, EPO and Network Management\u003c\/h3\u003e\n\u003cp\u003eThe SRVPM10KRIL is rated at unity power factor — 10000 VA gives a full 10000 W with no derating, and efficiency is better than 94% at rated load. An internal bypass operates automatically on overload or fault and can be commanded manually from the LCD console.\u003c\/p\u003e\n\u003cp\u003eA rear-panel Emergency Power Off connector accepts a normally-closed contact for a room EPO loop. The Intelligent Card Slot takes an AP9544 Network Management Card 3 for SNMP monitoring, alerting and network shutdown, with USB and RS-232 ports fitted as standard.\u003c\/p\u003e\n\u003ch3\u003eSupplied Locally, with GST Invoice and Singapore Warranty\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the SRVPM10KRIL as an APC by Schneider Electric product with a full GST invoice and local Singapore warranty support. APC's manufacturer term for this range is two years, repair or replace, and it applies worldwide — there is no separate European figure to catch you out. Schneider ask that the product be registered within ten days of purchase.\u003c\/p\u003e\n\u003cp\u003eBecause this is a hardwired unit, we would rather talk through the supply arrangement, the cabinet depth and the downstream distribution before you commit to a part number. Email sales@sourceit.com.sg with your load list and we will size it properly.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRVPM10KRIL Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral — SRVPM10KRIL Power Module\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line, 10kVA\/10kW, Rackmount 2U, 230V, 1x Hard wire 3-wire(1P+N+E) outlet, Intelligent Slot, Extended runtime, No battery, W\/O rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRVPM10KRIL + SRV240RLBP-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble conversion on-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eRackmount, 2U power module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBundle Composition\u003c\/td\u003e\n\u003ctd\u003eSRVPM10KRIL power module supplied together with one SRV240RLBP-9A battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eIncluded with every unit supplied by SourceIT, together with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eOutput — SRVPM10KRIL\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e10000 VA \/ 10000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Factor\u003c\/td\u003e\n\u003ctd\u003eUnity (1.0) — the watt rating equals the VA rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V, configurable to 220 V \/ 230 V \/ 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency (on battery)\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±1% static\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Distortion\u003c\/td\u003e\n\u003ctd\u003e1% max at full linear load; 4% max at full non-linear (RCD) load; 15% for the last 60 seconds of backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Crest Factor\u003c\/td\u003e\n\u003ctd\u003e3:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eGreater than 94% at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connection\u003c\/td\u003e\n\u003ctd\u003e1 x hard wire 3-wire (1P+N+E) terminal block — no IEC receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bypass\u003c\/td\u003e\n\u003ctd\u003eAutomatic and manual; bypass range 185–250 V AC ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this model — the load is fed continuously from the inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInput — SRVPM10KRIL\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (100% load)\u003c\/td\u003e\n\u003ctd\u003e176–300 V AC ±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (60% load)\u003c\/td\u003e\n\u003ctd\u003e110–300 V AC ±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e40–70 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Factor\u003c\/td\u003e\n\u003ctd\u003e0.99 or better at 100% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003e1 x hard wire 3-wire (1P+N+E) — hardwired, no inlet plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Protection\u003c\/td\u003e\n\u003ctd\u003eThermal circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e600 joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBatteries \u0026amp; Runtime\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Configuration\u003c\/td\u003e\n\u003ctd\u003eThe SRVPM10KRIL power module carries no internal batteries — Schneider's own product name for it ends “Extended runtime, No battery”. All stored energy is in the external pack(s).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Bus Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed maintenance-free VRLA (valve-regulated lead-acid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Pack Supplied\u003c\/td\u003e\n\u003ctd\u003e1 x SRV240RLBP-9A (240 V DC, 2160 VAh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Battery Packs\u003c\/td\u003e\n\u003ctd\u003eUp to 4 packs per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharger Power\u003c\/td\u003e\n\u003ctd\u003e1170 W rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 5 hours to 90% charge with one battery pack; each additional pack extends the recharge time. Charge current is configurable at 1 A, 2 A, 3 A or 4 A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Load\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this configuration — runtime depends on the load and the number of packs fitted; ask us for a sizing calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCommunications \u0026amp; Management\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eUSB port, RS-232 (DB-9) serial port, Intelligent Card Slot, EPO connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes — Emergency Power Off connector on the rear panel (normally-closed contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Panel\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eOptional AP9544 Network Management Card 3, fitted in the Intelligent Card Slot. Schneider's network management card compatibility chart covers the SRV 5–20 kVA range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBundled Shutdown Software\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for the 6\/10 kVA range — use the network management card for monitoring and shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental — SRVPM10KRIL\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e2U for the power module; 5U in total once the 3U battery pack is racked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e86.5 x 438 x 615 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaged Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e240 x 600 x 760 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e2128 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e58 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight Source Note\u003c\/td\u003e\n\u003ctd\u003eThe power module net and shipping weights are printed only in Schneider user manual 990-91615 and are not corroborated by a second document, so treat them as approximate for freight purposes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–40 °C at rated load; 40–45 °C derated linearly to 85% load; 45–50 °C derated linearly to 75% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−15 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e0–95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0–1000 m at full output; 1000–3000 m output derates 1% per 100 m; the UPS will not operate above 3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection \u0026amp; Installation Class\u003c\/td\u003e\n\u003ctd\u003eIP20, pollution degree 2, overvoltage category II, TN power system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, EAC, TISI; EN\/IEC 62040-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eUSB cable, RS-232 serial cable, user documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBattery Pack — SRV240RLBP-9A\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV Battery Pack (6\/10kVA) for Extended Runtime Model 240V, 2160VAh, rackmount with kit, 3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eSRV240RLBP-9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Bus Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e2160 VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Blocks\u003c\/td\u003e\n\u003ctd\u003e20 x 12 V 9 Ah sealed maintenance-free VRLA blocks per string\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eRackmount, 3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e133 x 438 x 606 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e250 x 870 x 580 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e63 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Quantity\u003c\/td\u003e\n\u003ctd\u003eUp to 4 packs per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003e5 kVA \/ 6 kVA \/ 10 kVA Easy UPS On-Line SRV extended-runtime models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e0–40 °C, 0–95% RH non-condensing, 0–3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, EAC, EN\/IEC 62040-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eUser manual, battery cable, rack mounting brackets (mounting kit included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Cartridge Part Number\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat Connects to This UPS\u003c\/h3\u003e\n\u003cp\u003eThere are no IEC sockets on this model. Schneider's product name specifies a single hard-wire 3-wire (1P+N+E) output, which is a terminal block. In practice the UPS output feeds a rack PDU, a sub-distribution board or a dedicated final circuit, and your equipment plugs into that. The input is a matching hard-wire 3-wire terminal block, so there is no plug to fit into a wall socket. Both ends must be terminated by a licensed electrician.\u003c\/p\u003e\n\u003cp\u003eSizing guidance: this unit is rated at unity power factor, so its 10000 W rating is the real continuous watts available. A 10000 W load draws in the order of 44 A at 230 V on the output side, and the supply circuit, breaker and cabling need to be sized accordingly, with headroom for battery recharge current on top of the load.\u003c\/p\u003e\n\u003ch3\u003eBattery Packs and Scaling Runtime\u003c\/h3\u003e\n\u003cp\u003eThe SRVPM10KRIL power module holds no batteries. It is supplied here with one SRV240RLBP-9A pack (240 V DC, 2160 VAh) and accepts \u003cstrong\u003eup to four packs\u003c\/strong\u003e in total, so runtime can be extended later without changing the UPS. The packs run on a 240 V DC bus and are built from 20 x 12 V 9 Ah sealed VRLA blocks per string.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo not cross-order packs between ranges.\u003c\/strong\u003e The 192 V battery modules used by the standard-runtime SRV6KRIRK and SRV10KRIRK (SRV192RBP-7A \/ SRV192RBP-9A) are a different bus voltage and are not interchangeable with these 240 V packs. Schneider does not publish a replacement cartridge part number for the packs themselves, and makes no hot-swap claim for them, so we do not make one either.\u003c\/p\u003e\n\u003ch3\u003eRack Fit, Depth and Weight\u003c\/h3\u003e\n\u003cp\u003eBudget \u003cstrong\u003e5U\u003c\/strong\u003e for the delivered system: 2U for the power module and 3U for the battery pack, plus a further 3U for each additional pack. The power module is 615 mm deep and the pack 606 mm, so a standard 600 mm cabinet will not take either — plan on 700–900 mm. The pack weighs 63 kg, so mount it low and check the cabinet's static load rating.\u003c\/p\u003e\n\u003cp\u003eThe battery pack includes its rack mounting kit. Schneider's name for the power module ends “W\/O rail kit”, so please confirm the module's mounting hardware with us at quotation stage rather than assuming rails are in the box.\u003c\/p\u003e\n\u003ch3\u003eRuntime\u003c\/h3\u003e\n\u003cp\u003eSchneider publishes no runtime figures for this configuration, so we do not print any. Runtime depends on the load and on how many packs are fitted. Tell us the load in watts and the hold-up time you need and we will calculate the pack count with the distributor.\u003c\/p\u003e\n\u003ch3\u003eManagement and Software\u003c\/h3\u003e\n\u003cp\u003eThe Intelligent Card Slot accepts an AP9544 Network Management Card 3; Schneider's card compatibility chart covers the SRV 5–20 kVA range. USB and RS-232 serial ports are fitted as standard, and a rear-panel EPO connector takes a normally-closed contact for a room emergency power off loop.\u003c\/p\u003e\n\u003cp\u003eSchneider does not document a bundled shutdown software package for the 6 and 10 kVA models, so we do not advertise one — network monitoring and shutdown are provided by the management card. The APV9601 card listed in our catalogue is documented for the smaller Easy UPS On-Line SRV models and should not be ordered for this unit.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cp\u003eUSB cable, RS-232 serial cable, user documentation\u003c\/p\u003e\n\u003cp\u003eSupplied with it: 1 x SRV240RLBP-9A battery pack — User manual, battery cable, rack mounting brackets (mounting kit included).\u003c\/p\u003e\n\u003ch3\u003eEasy UPS On-Line SRV 6–10 kVA Ordering Information\u003c\/h3\u003e\n\u003cp\u003eEvery model below is hardwired at both input and output. Choose by rating first, then by form factor, then by whether you need standard or extended runtime.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-6000va-230v-srv6ki\"\u003eSRV6KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kVA \/ 6 kW\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003ctd\u003eInternal battery, standard runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-10000va-230v-srv10ki\"\u003eSRV10KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA \/ 10 kW\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003ctd\u003eInternal battery, standard runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-6000va-230v-with-railkit-external-battery-pack-srv6krirk\"\u003eSRV6KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kVA \/ 6 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 4U, rail kit\u003c\/td\u003e\n\u003ctd\u003e192 V battery module included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-rm-10000va-230v-with-railkit-external-battery-pack-srv10krirk\"\u003eSRV10KRIRK\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA \/ 10 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 4U, rail kit\u003c\/td\u003e\n\u003ctd\u003e192 V battery module included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-6000va-rm-230v-with-extended-runtime-battery-srv6kril\"\u003eSRVPM6KRIL + SRV240RLBP-9A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kVA \/ 6 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U + 3U pack\u003c\/td\u003e\n\u003ctd\u003e240 V pack, extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-10000va-230v-with-extended-runtime-battery-pack-srv10kil\"\u003eSRVPM10KIL + SRV240BP-9A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA \/ 10 kW\u003c\/td\u003e\n\u003ctd\u003eTower + tower pack\u003c\/td\u003e\n\u003ctd\u003e240 V pack, extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSRVPM10KRIL + SRV240RLBP-9A (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA \/ 10 kW\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U + 3U pack\u003c\/td\u003e\n\u003ctd\u003e240 V pack, extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eAccessories and Replacement Batteries\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV192RBP-7A\u003c\/td\u003e\n\u003ctd\u003eReplacement 192 V battery module for the SRV6KRIRK. Not currently stocked — email sales@sourceit.com.sg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV192RBP-9A\u003c\/td\u003e\n\u003ctd\u003eReplacement 192 V battery module for the SRV10KRIRK. Not currently stocked — email sales@sourceit.com.sg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV240BP-9A\u003c\/td\u003e\n\u003ctd\u003e240 V 2160 VAh tower battery pack for the extended-runtime tower models, up to 4 per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRV240RLBP-9A\u003c\/td\u003e\n\u003ctd\u003e240 V 2160 VAh 3U rackmount battery pack with mounting kit, for the extended-runtime rack models, up to 4 per UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9544\u003c\/td\u003e\n\u003ctd\u003eNetwork Management Card 3 for the Intelligent Card Slot, per Schneider's card compatibility chart for SRV 5–20 kVA. Not currently stocked — email sales@sourceit.com.sg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRVRK1 \/ SRVRK2\u003c\/td\u003e\n\u003ctd\u003eRail kits named by Schneider as optional accessories for the base SRV6KRI \/ SRV10KRI. SRVRK2 is the 900 mm depth kit for the battery module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eSmaller Ratings in the Same Family\u003c\/h3\u003e\n\u003cp\u003eIf 6 kVA is more than you need, the 1–3 kVA Easy UPS On-Line SRV models use IEC outlets and a standard plug, so they need no electrician.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-230v-srv1ki\"\u003eSRV1KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kVA \/ 800 W\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-srv2ki\"\u003eSRV2KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kVA \/ 1600 W\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-srv3ki\"\u003eSRV3KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kVA \/ 2400 W\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri\"\u003eSRV1KRI + SRVRK1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kVA \/ 800 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri\"\u003eSRV2KRI + SRVRK1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kVA \/ 1600 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri\"\u003eSRV3KRI + SRVRK1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kVA \/ 2400 W\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eSchneider Electric hosts the official documentation for this product. The link below is the product page we verified resolves and shows the correct part number.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric product page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/be\/en\/product\/SRVPM10KRIL\/apc-easy-ups-online-10kva-10kw-rackmount-2u-230v-1x-hard-wire-3wire1p+n+e-outlet-intelligent-slot-extended-runtime-no-battery-w-o-rail-kit\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC SRVPM10KRIL on se.com\u003c\/a\u003e — Belgium (no Singapore page is published for this part number) site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery pack product page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/eg\/en\/product\/SRV240RLBP-9A\/apc-easy-ups-online-srv-battery-pack-6-10kva-for-extended-runtime-model-240v-2160vah-rackmount-with-kit-3u\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC SRV240RLBP-9A on se.com\u003c\/a\u003e — Egypt site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eSRVPM10KRIL\u003c\/strong\u003e and we will send you the current PDF datasheet and user manual directly.\u003c\/p\u003e\n\u003cp\u003eThe governing document for this model is Schneider user manual 990-91615, which covers the SRV5KRIL, SRV6KRIL, SRV10KRIL, SRV6KIL and SRV10KIL extended-runtime models.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRVPM10KRIL\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat is the difference between the VA and the watt rating, and how do I size this UPS?\u003c\/h3\u003e\n\u003cp\u003eVA is apparent power and watts is real power. On most UPS ranges the watt figure is lower than the VA figure, so the watt rating is the one that limits what you can connect. This model is unusual and welcome in that it is rated at unity power factor: 10000 VA gives a full 10000 W. Add up the continuous watts of everything you intend to protect, leave headroom for start-up surge and for future growth, and check the total against 10000 W. Send us the list and we will do it with you.\u003c\/p\u003e\n\u003ch3\u003eDoes this model have IEC outlets I can plug servers into?\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider's product name specifies a hard-wire 3-wire (1P+N+E) output, which is a terminal block. There are no C13 or C19 sockets on the unit at all, and the input is hardwired too. The output feeds a rack PDU or a distribution board, and a licensed electrician must terminate both ends. If you need a UPS you can simply plug into, look at the 1–3 kVA Easy UPS On-Line SRV models instead.\u003c\/p\u003e\n\u003ch3\u003eWhat runtime will I get?\u003c\/h3\u003e\n\u003cp\u003eSchneider does not publish a runtime table for this model, and we will not print a figure we cannot source. Runtime depends on how heavily the UPS is loaded — a unit at 30 per cent load runs far longer than the same unit at 90 per cent. Email sales@sourceit.com.sg with your load in watts and the hold-up time you need and we will get a proper figure from the distributor.\u003c\/p\u003e\n\u003ch3\u003eWhat does the “PM” in SRVPM10KRIL mean, and where are the batteries?\u003c\/h3\u003e\n\u003cp\u003ePM stands for power module. Schneider's official name for this part ends “Extended runtime, No battery”: the module itself contains no batteries at all. All the stored energy is in the external SRV240RLBP-9A pack supplied with it, and up to four packs can be fitted to one UPS. That is precisely why this configuration can be scaled to long runtimes that a standard-runtime UPS cannot reach.\u003c\/p\u003e\n\u003ch3\u003eCan I use the battery packs from the standard-runtime SRV6KRIRK or SRV10KRIRK?\u003c\/h3\u003e\n\u003cp\u003eNo, and this is worth being careful about. The standard-runtime rack models run a 192 V DC battery bus and use a complete replacement battery module (SRV192RBP-7A or SRV192RBP-9A). The extended-runtime models on this page run a 240 V DC bus and use the SRV240BP-9A or SRV240RLBP-9A packs. The two are not interchangeable in either direction.\u003c\/p\u003e\n\u003ch3\u003eHow much rack space does it need, and will it fit my cabinet?\u003c\/h3\u003e\n\u003cp\u003eThe delivered system occupies 5U (2U power module plus a 3U battery pack). Depth is the thing to check: at 615 mm the chassis will not fit a standard 600 mm comms cabinet, so plan on a deeper rack, typically 800–900 mm, with rear clearance for the hardwired conduit. Please measure before you order — depth is the most common cause of an avoidable return on a unit this size.\u003c\/p\u003e\n\u003ch3\u003eHow do I monitor it over the network?\u003c\/h3\u003e\n\u003cp\u003eThe Intelligent Card Slot takes an AP9544 Network Management Card 3, which Schneider's compatibility chart covers for the SRV 5–20 kVA range. That gives SNMP monitoring, alerting and network shutdown. USB and RS-232 ports are fitted as standard. Schneider does not document a bundled shutdown software package for the 6 and 10 kVA models, so please do not assume PowerChute over USB — ask us and we will confirm what is supported for your build. The APV9601 card in our catalogue is for the smaller Easy UPS On-Line SRV models and should not be ordered for this one.\u003c\/p\u003e\n\u003ch3\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC SRVPM10KRIL sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRVPM10KRIL with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bzQk-YuLvCM\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039392989348,"sku":"SRVPM10KRIL + SRV240RLBP-9A","price":5115.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-easy-ups-srv-rm-10000va-230v-with-external-battery-pack-srv10krirk-443599.jpg?v=1671740216"},{"product_id":"apc-easy-ups-on-line-srv-snmp-card-apv9601","title":"APC Easy UPS On-Line SRV SNMP Card","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Easy UPS On-Line SRV SNMP Card (APV9601) - Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eSNMP Network Monitoring for APC Easy UPS On-Line SRV\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC Easy UPS On-Line SRV SNMP Card (APV9601) slots into the Intelligent Card Slot of an Easy UPS On-Line SRV and puts the UPS on your network. Input and output voltage, battery condition and load level become readable over SNMP v1, v2c or v3, so a UPS in a comms cabinet on another floor stops being a device somebody has to walk to.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eThe Right Card for an Easy UPS — Not a Smart-UPS Card\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis is the part of the APC accessory range that catches people out. Easy UPS On-Line SRV uses an \u003cstrong\u003eIntelligent Card Slot\u003c\/strong\u003e and takes the APV9601. Smart-UPS SMT, SMC, SMX and SRT use a \u003cstrong\u003eSmartSlot\u003c\/strong\u003e and take the AP9640 or AP9641 Network Management Card 3. The two are not interchangeable, and Easy UPS SMV takes a third card again, the APV9602. Buy against your actual UPS model, and if you are not certain, send us the serial number.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eUnattended Shutdown for Singapore Server Rooms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA network-managed UPS is what turns a power event into a controlled shutdown instead of a hard stop. With the APV9601 fitted, SchneiderUPS Network Shutdown can bring hosts down cleanly when the battery reaches a set threshold — worth having in an SME server room or comms cabinet where nobody is on site when a storm takes the grid down.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBuy the APV9601 in Singapore with GST Invoice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the APV9601 from Singapore stock with a GST invoice and local warranty support. Schneider has moved this range to the AP9544 card for new deployments, so if you are designing a monitoring scheme from scratch rather than adding a card to an installed Easy UPS On-Line SRV, ask us which is the better buy — \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC APV9601 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAPV9601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider product name\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV Network Management Card, with direct SNMP connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eSNMP network management card for APC Easy UPS On-Line SRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocument reference\u003c\/td\u003e\n\u003ctd\u003eEasy UPS On-Line SRV SNMP Card User Guide, EN 990-91198A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePublished firmware\u003c\/td\u003e\n\u003ctd\u003ev2.0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle\u003c\/td\u003e\n\u003ctd\u003eSchneider lists APV9601 as discontinued (31 Aug 2023), with end of standard service 31 Aug 2024. The current-generation Schneider card for Easy UPS On-Line 1-phase is AP9544.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eFunction \u0026amp; Connectivity\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork interface\u003c\/td\u003e\n\u003ctd\u003eRJ-45, auto-sensing 10\/100 Mbps Fast Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus indicators\u003c\/td\u003e\n\u003ctd\u003eStatus LED, 100M link LED (green), 10M link LED (yellow)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSNMP versions\u003c\/td\u003e\n\u003ctd\u003eSNMP v1, v2c and v3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport protocols\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP and UDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP addressing\u003c\/td\u003e\n\u003ctd\u003eDHCP supported; a static address is assigned using the APC Easy UPS On-Line UPS Monitoring Software (SFAPV9601)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration method\u003c\/td\u003e\n\u003ctd\u003eVia the APC Easy UPS On-Line UPS Monitoring Software running on a PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnattended shutdown\u003c\/td\u003e\n\u003ctd\u003eSupports SchneiderUPS Network Shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eSNMP v3 is Schneider's recommended setting. The card ships with default password 12345678 and does not force a change — change it during commissioning.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor port\u003c\/td\u003e\n\u003ctd\u003ePhysically present, but Schneider's user guide states the temperature and smoke sensor accessory is not available for the SRV and SRVS series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits\u003c\/td\u003e\n\u003ctd\u003eAPC Easy UPS On-Line SRV series, in the UPS Intelligent Card Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e47 mm (W) × 25 mm (H) × 80 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg (card); 0.3 kg packaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage dimensions\u003c\/td\u003e\n\u003ctd\u003e168 mm × 42 mm × 132 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack mountable\u003c\/td\u003e\n\u003ctd\u003eNo — the card installs inside the UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity\u003c\/td\u003e\n\u003ctd\u003e0–95 % relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider publishes no warranty term for the APV9601 in any document we were able to verify, and its own regional product pages render no warranty field, so no duration is claimed above. SourceIT supplies the card with local Singapore warranty support and a GST invoice — email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e for the current term in writing before you order.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Fitment\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhich UPS models the APV9601 fits\u003c\/h4\u003e\n\u003cp\u003eSchneider's user guide states the card “can be installed in any compatible device that has an Intelligent Card Slot, including: Easy UPS On-Line: SRV series UPS”. In practice that means the \u003cstrong\u003eAPC Easy UPS On-Line SRV\u003c\/strong\u003e range and nothing else.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEasy UPS On-Line SRV model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-230v-srv1ki\"\u003eAPC Easy UPS On-Line SRV1KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-srv2ki\"\u003eAPC Easy UPS On-Line SRV2KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-srv3ki\"\u003eAPC Easy UPS On-Line SRV3KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri\"\u003eAPC Easy UPS On-Line SRV1KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA rackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri\"\u003eAPC Easy UPS On-Line SRV2KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA rackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri\"\u003eAPC Easy UPS On-Line SRV3KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA rackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-external-battery-pack-srv3kri\"\u003eAPC Easy UPS On-Line SRVPM1KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-with-extended-runtime-battery-pack-srv2kil\"\u003eAPC Easy UPS On-Line SRVPM2KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-with-extended-runtime-battery-pack-srv3kil\"\u003eAPC Easy UPS On-Line SRVPM3KIL\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA extended runtime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-6000va-230v-srv6ki\"\u003eAPC Easy UPS On-Line SRV6KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-srv-10000va-230v-srv10ki\"\u003eAPC Easy UPS On-Line SRV10KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 VA tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eEvery model above carries an Intelligent Card Slot in its Schneider product name. Schneider does not publish a per-SKU compatibility matrix for the APV9601, so if you are fitting a card to an older or a non-SRV unit, email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with the UPS serial number and we will confirm before shipping.\u003c\/p\u003e\n\u003ch4\u003eWhat it does not fit — read this before ordering\u003c\/h4\u003e\n\u003cp\u003eThree genuine mix-ups are worth stating plainly:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart-UPS (SMT, SMC, SMX, SRT) is not supported.\u003c\/strong\u003e Those units use a \u003cem\u003eSmartSlot\u003c\/em\u003e and take the AP9640 \/ AP9641 Network Management Card 3. Schneider's APV9601 documentation makes no mention of any Smart-UPS model.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy UPS SMV and Easy UPS LI take the APV9602\u003c\/strong\u003e, not this card. Reseller copy claiming the APV9601 “suits SMV and SRV” is wrong.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe SRVS series takes the APVS9601\u003c\/strong\u003e, a separate part number with its own user guide.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironmental monitoring\u003c\/h4\u003e\n\u003cp\u003eThe card has a sensor port, but Schneider's user guide states in terms that the temperature and smoke sensor accessory \u003cstrong\u003eis not available for the SRV and SRVS series\u003c\/strong\u003e. If you need rack temperature and humidity monitoring alongside an Easy UPS On-Line, plan a separate sensor path rather than expecting it from this card.\u003c\/p\u003e\n\u003ch4\u003eNetwork and management support\u003c\/h4\u003e\n\u003cp\u003eThe card presents SNMP v1, v2c and v3 over a 10\/100 Mbps RJ-45 port, supports DHCP, and is configured from the APC Easy UPS On-Line UPS Monitoring Software (SFAPV9601) rather than a browser — Schneider's user guide documents no web interface, HTTPS, SSH or email alerting for this card, so we do not advertise them. Unattended shutdown is via SchneiderUPS Network Shutdown. PowerChute Network Shutdown and EcoStruxure IT support are not documented for the APV9601 and are not claimed here.\u003c\/p\u003e\n\u003cp\u003eSecurity note worth acting on: the card ships with default password \u003cstrong\u003e12345678\u003c\/strong\u003e and does not force a change at first login. Change it and move to SNMP v3 during commissioning.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Easy UPS On-Line SRV Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 × APV9601 SNMP card\u003c\/li\u003e\n\u003cli\u003e1 × user manual\u003c\/li\u003e\n\u003cli\u003e1 × utility CD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhich UPS to pair it with\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEasy UPS On-Line SRV tower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-230v-srv1ki\"\u003eAPC Easy UPS On-Line SRV1KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-230v-srv2ki\"\u003eAPC Easy UPS On-Line SRV2KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-230v-srv3ki\"\u003eAPC Easy UPS On-Line SRV3KI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEasy UPS On-Line SRV rackmount 2U\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity, outlets and cartridge\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-1000va-rm-230v-with-rail-kit-srv1kri\"\u003eAPC Easy UPS On-Line SRV1KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W · 3 × C13 · APCRBCV200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-2000va-rm-230v-with-rail-kit-srv2kri\"\u003eAPC Easy UPS On-Line SRV2KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1600 W · 4 × C13 · APCRBCV201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-ups-on-line-srv-3000va-rm-230v-with-rail-kit-srv3kri\"\u003eAPC Easy UPS On-Line SRV3KRI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W · 6 × C13 + 1 × C19 · APCRBCV202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/APV9601\/apc-easy-ups-online-srv-network-management-card-with-direct-snmp-connection\/\" target=\"_blank\" rel=\"noopener\"\u003eOfficial Schneider Electric product page for the APC APV9601\u003c\/a\u003e — Singapore regional page. Schneider publishes the product datasheet, user guide and environmental disclosure from the document list on that page.\u003c\/p\u003e\n\u003cp\u003eSchneider serves its APC datasheet PDFs from a redirecting download host that regularly returns the wrong model's document, so we do not publish direct PDF links that we cannot verify resolve to the right part number. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with the model you need and we will send the correct current-revision datasheet and user manual, along with a GST-invoiced quotation.\u003c\/p\u003e\n\u003cp\u003eEvery specification on this page was taken from Schneider Electric's own product page and its published product datasheet or user manual for this exact part number. Where Schneider's own sources disagreed, or published nothing, the field has been left out rather than estimated.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC APV9601\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhich UPS models does the APV9601 fit?\u003c\/h4\u003e\n\u003cp\u003eThe APC Easy UPS On-Line \u003cstrong\u003eSRV\u003c\/strong\u003e series, in the UPS Intelligent Card Slot. Schneider's user guide scopes it to “Easy UPS On-Line: SRV series UPS” and does not publish a per-SKU list, so if you are fitting an older unit, send us the serial number first.\u003c\/p\u003e\n\u003ch4\u003eWill it work in a Smart-UPS SMT, SMC, SMX or SRT?\u003c\/h4\u003e\n\u003cp\u003eNo. Smart-UPS models use a \u003cem\u003eSmartSlot\u003c\/em\u003e and take the AP9640 or AP9641 Network Management Card 3. Schneider's APV9601 documentation makes no mention of any Smart-UPS model. This is the single most common ordering mistake on this part — if your UPS is a Smart-UPS, you want an AP964x card instead.\u003c\/p\u003e\n\u003ch4\u003eDoes it give me rack temperature and humidity monitoring?\u003c\/h4\u003e\n\u003cp\u003eNo, not on an SRV. The card has a sensor port, but Schneider's user guide states directly that the temperature and smoke sensor accessory is \u003cstrong\u003enot available for the SRV and SRVS series\u003c\/strong\u003e — and SRV is the only range this card fits. If you need environmental monitoring in the same cabinet, plan a separate sensor path and talk to us about it.\u003c\/p\u003e\n\u003ch4\u003eCan I manage it from a web browser?\u003c\/h4\u003e\n\u003cp\u003eSchneider's user guide for the APV9601 documents configuration through the APC Easy UPS On-Line UPS Monitoring Software (SFAPV9601) on a PC, and describes no web interface, HTTPS, SSH or email alerting. We therefore do not advertise those. What is documented is SNMP v1, v2c and v3 over a 10\/100 Mbps RJ-45 port, DHCP addressing, and unattended shutdown through SchneiderUPS Network Shutdown.\u003c\/p\u003e\n\u003ch4\u003eIs it secure out of the box?\u003c\/h4\u003e\n\u003cp\u003eNot until you configure it. The card ships with default password \u003cstrong\u003e12345678\u003c\/strong\u003e and does not force a change at first login. Change the password and switch to SNMP v3 during commissioning — Schneider's own guidance recommends exactly this. Treat the card as a managed network device and put it on your management VLAN.\u003c\/p\u003e\n\u003ch4\u003eSchneider lists this card as discontinued — should I still buy it?\u003c\/h4\u003e\n\u003cp\u003eIt depends on why you need it. Schneider marks APV9601 as discontinued from 31 Aug 2023 with end of standard service from 31 Aug 2024, and names \u003cstrong\u003eAP9544\u003c\/strong\u003e (Network Management Card 3 for Easy UPS On-Line 1-Phase) as the current-generation replacement. If you are adding a card to an existing Easy UPS On-Line SRV, the APV9601 is the card that unit was designed around and SourceIT holds stock. If you are specifying a new deployment, ask us about AP9544 first — email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch4\u003eIs the APV9601 covered by warranty in Singapore?\u003c\/h4\u003e\n\u003cp\u003eEvery APC APV9601 sold by SourceIT comes with local Singapore warranty and a GST invoice. Schneider does not publish a warranty duration for this card in any document we were able to verify, and its own product pages render no warranty field, so we do not state a number here rather than quote one we cannot stand behind. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e and we will confirm the current term in writing before you order.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43039395905700,"sku":"APV9601","price":265.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-easy-ups-on-line-srv-snmp-card-apv9601-105627.jpg?v=1671740214"},{"product_id":"apc-smart-ups-on-line-3kva-rackmount-2u-230v-8x-c13-2x-c19-iec-srt3000rmxli","title":"APC Smart-UPS On-Line 3kVA Rackmount 2U 230V","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Smart-UPS On-Line 3kVA Rackmount 2U 230V (SRT3000RMXLI) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eDouble-Conversion On-Line Power Protection for Singapore's 230V Mains\u003c\/h3\u003e\n\u003cp\u003eThe APC Smart-UPS SRT 3 kVA (SRT3000RMXLI) is an on-line, double-conversion UPS: incoming mains is rectified to DC and regenerated as a clean sine wave output, so the load is fed from the inverter continuously rather than being switched over when the supply fails. On Singapore's 230V \/ 50Hz supply that matters most during the afternoon storm season, when PUB grid dips, brownouts and momentary interruptions are common enough to reset a server or corrupt a database write. Schneider specifies the SRT3000RMXLI to accept an input range of 100-275 V adjustable (half load) at 40-70Hz auto-sensing, so it rides through sag and swell without drawing on the battery.\u003c\/p\u003e\n\u003ch3\u003e3,000 VA \/ 2,700 W of Sine Wave Output on (8) C13 and (2) C19 Outlets\u003c\/h3\u003e\n\u003cp\u003eSchneider rates the SRT3000RMXLI at 3,000 VA \/ 2,700 W with a nominal 230V AC single-phase output at 50\/60Hz (±3Hz, synchronised to mains) and a sine wave output waveform. Outlets are (8) IEC 60320 C13 and (2) IEC 60320 C19, so it will take a mixed load of rack servers, switches, NAS and comms equipment; the C19 outlets suit higher-draw devices such as blade chassis and larger storage arrays. Size on watts, not VA: total the real power draw of everything you intend to protect and keep it comfortably under 2,700 W.\u003c\/p\u003e\n\u003ch3\u003eRuntime and Extended Runtime with SRT Battery Packs\u003c\/h3\u003e\n\u003cp\u003eSchneider's published runtime for the SRT3000RMXLI on its internal battery is 11.8 minutes at half load (1,350 W) and 4.0 minutes at full load (2,700 W) — enough to ride out a short outage or to shut a rack down cleanly. Where you need longer, the SRT3000RMXLI accepts external battery packs: the SRT96RMBP matches this unit's 96V battery bus, the UPS will recognise as many as ten packs, and the internal cartridge is the APCRBC152. Battery service life in a Singapore comms cabinet depends heavily on ambient temperature, so keep the room cool and dry; Schneider rates the unit for 0-40°C operation at 0-95% non-condensing humidity.\u003c\/p\u003e\n\u003ch3\u003e2U Rack-Ready, Rail Kit Included\u003c\/h3\u003e\n\u003cp\u003eThe SRT3000RMXLI occupies 2U (85 mm) of rack height in a 85 mm (H) x 432 mm (W) x 635 mm (D) chassis and ships \u003cstrong\u003ewith the rail kit included\u003c\/strong\u003e, so it goes straight into a standard 19-inch cabinet without a separate accessory order. Net weight is 31.3 kg — plan the lift and mount it low in the cabinet. The same chassis converts to tower orientation if the deployment changes. Check your cabinet depth against the 635 mm (D) figure before ordering.\u003c\/p\u003e\n\u003ch3\u003eManagement, Monitoring and Local Singapore Supply\u003c\/h3\u003e\n\u003cp\u003eSerial (RJ45) and USB (Type A) interface ports are built in, together with an available SmartSlot for an APC Network Management Card 3 (AP9640 or AP9641) where you need SNMP, web access or EcoStruxure IT monitoring, and an emergency power off (EPO) connection. A multi-function LCD console gives status and configuration at the unit. Audible noise is rated at 55 dBA. SourceIT supplies the SRT3000RMXLI from Singapore stock with a GST invoice and local warranty support — no overseas RMA, no import paperwork.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRT3000RMXLI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRT3000RMXLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS On-Line, 3kVA, Rackmount 2U, 230V, 8x C13+2x C19 IEC outlets, SmartSlot, Extended runtime, W\/ rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPS Type \/ Topology\u003c\/td\u003e\n\u003ctd\u003eOn-Line, double conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN \/ UPC\u003c\/td\u003e\n\u003ctd\u003e731304273574\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e3,000 VA \/ 2,700 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±3 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003e(8) IEC 60320 C13 and (2) IEC 60320 C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e100-275 V adjustable (half load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e40-70 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C20, BS 1363 (British) or CEE 7\/7 (Schuko); 2.4 m input cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed, maintenance-free, valve-regulated lead-acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e96 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e3 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Runtime at Half Load\u003c\/td\u003e\n\u003ctd\u003e11.8 minutes (1,350 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Runtime at Full Load\u003c\/td\u003e\n\u003ctd\u003e4.0 minutes (2,700 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible External Battery Packs\u003c\/td\u003e\n\u003ctd\u003eSRT96BP (tower) \/ SRT96RMBP (rackmount), up to 10 packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Ports\u003c\/td\u003e\n\u003ctd\u003eSerial (RJ45), USB (Type A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmartSlot\u003c\/td\u003e\n\u003ctd\u003eYes — accepts APC Network Management Card 3 (AP9640 \/ AP9641) and other SmartSlot accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management Card\u003c\/td\u003e\n\u003ctd\u003eNot included — SmartSlot is supplied empty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes (NO\/NC connections)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Panel\u003c\/td\u003e\n\u003ctd\u003eMulti-function LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e85 mm (H) x 432 mm (W) x 635 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e31.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e2U (85 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRail Kit\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcoustic Level\u003c\/td\u003e\n\u003ctd\u003e55 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 3,000 m (0 to 10,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards \u0026amp; Marks\u003c\/td\u003e\n\u003ctd\u003eCE, EAC, RCM, VDE, UK PSTI, EN\/IEC 62040-1:2019\/A11:2021, EN\/IEC 62040-2:2018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e3 years UPS electronics \/ 2 years battery (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003e2 years, supplied and supported by SourceIT Pte Ltd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug in.\u003c\/strong\u003e The SRT3000RMXLI provides (8) IEC 60320 C13 and (2) IEC 60320 C19. All outlets are battery-backed. Total the real power draw (watts) of the equipment you intend to protect and keep it below the 2,700 W rating — runtime falls sharply as load rises, as the figures below show.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal battery, half load (1,350 W)\u003c\/td\u003e\n\u003ctd\u003e11.8 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal battery, full load (2,700 W)\u003c\/td\u003e\n\u003ctd\u003e4.0 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRuntime depends on load.\u003c\/strong\u003e These are Schneider's published estimates for a healthy battery at 25°C; real runtime varies with load, battery age and ambient temperature, which in an unconditioned Singapore comms cabinet can shorten battery life considerably.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtended runtime.\u003c\/strong\u003e Connect SRT96BP (tower) or SRT96RMBP (rackmount) external battery packs on the 96V battery bus. The UPS will recognise as many as ten packs. Recharge time increases with each pack added.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e Occupies 2U (85 mm) and ships with the rail kit included; chassis depth is 635 mm (D).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput and circuit.\u003c\/strong\u003e The SRT3000RMXLI input is IEC 60320 C20, BS 1363 (British) or CEE 7\/7 (Schuko); 2.4 m input cord. At 2,700 W a dedicated 13A or 16A supply is the sensible provision; confirm the circuit with your electrician before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork management.\u003c\/strong\u003e The SmartSlot is supplied empty. Fit an \u003ca href=\"\/products\/apc-ups-network-management-card-3-ap9640\" target=\"_blank\" rel=\"noopener\"\u003eAP9640\u003c\/a\u003e or \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\" target=\"_blank\" rel=\"noopener\"\u003eAP9641\u003c\/a\u003e Network Management Card 3 for SNMP, HTTPS and EcoStruxure IT monitoring; the AP9641 adds environmental monitoring inputs for the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\" target=\"_blank\" rel=\"noopener\"\u003eAP9335TH\u003c\/a\u003e sensor. Serial and USB are built in for direct PowerChute connection to a single host.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Smart-UPS SRT Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eIn the box:\u003c\/strong\u003e UPS unit, rail kit and rack mounting brackets, battery cable\/connector hardware, user documentation and warranty card. Exact contents are listed in the APC user guide linked in the Downloads section below.\u003c\/p\u003e\n\u003ch4\u003eSmart-UPS SRT 1-3 kVA range at SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-1000va-230v-srt1000xli\" target=\"_blank\" rel=\"noopener\"\u003eSRT1000XLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 VA \/ 1,000 W · Tower · no rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-1500va-230v-srt1500xli\" target=\"_blank\" rel=\"noopener\"\u003eSRT1500XLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1,500 VA \/ 1,500 W · Tower · no rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-2200va-230v-srt2200xli\" target=\"_blank\" rel=\"noopener\"\u003eSRT2200XLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2,200 VA \/ 1,980 W · Tower · no rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-3000va-230v-srt3000xli\" target=\"_blank\" rel=\"noopener\"\u003eSRT3000XLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000 VA \/ 2,700 W · Tower · no rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-on-line-1000va-1000w-rackmount-2u-230v-srt1000rmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT1000RMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 VA \/ 1,000 W · Rackmount 2U · rail kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-on-line-1500va-1500w-rackmount-2u-230v-srt1500rmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT1500RMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1,500 VA \/ 1,500 W · Rackmount 2U · rail kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-2200va-rm-230v-srt2200rmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT2200RMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2,200 VA \/ 1,980 W · Rackmount 2U · rail kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSRT3000RMXLI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000 VA \/ 2,700 W · Rackmount 2U · rail kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMatching external battery packs\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-96v-3kva-battery-pack-srt96bp\" target=\"_blank\" rel=\"noopener\"\u003eSRT96BP\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e96 V, SRT 3 kVA · Tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-96v-3kva-rm-battery-pack-srt96rmbp\" target=\"_blank\" rel=\"noopener\"\u003eSRT96RMBP\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e96 V, SRT 3 kVA · Rackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eReplacement battery cartridge\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003eAPCRBC152\u003c\/td\u003e\n\u003ctd\u003eInternal replacement battery cartridge for the SRT3000RMXLI\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch4\u003eNetwork management and SmartSlot accessories\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-ap9640\" target=\"_blank\" rel=\"noopener\"\u003eAP9640\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eUPS Network Management Card 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\" target=\"_blank\" rel=\"noopener\"\u003eAP9641\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eUPS Network Management Card 3 with Environmental Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-dry-contact-i-o-smartslot-card-ap9613\" target=\"_blank\" rel=\"noopener\"\u003eAP9613\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eDry Contact I\/O SmartSlot Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-temperature-humidity-sensor\" target=\"_blank\" rel=\"noopener\"\u003eAP9335TH\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature \u0026amp; Humidity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/SRT3000RMXLI\/apc-smartups-online-3kva-rackmount-2u-230v-8x-c13+2x-c19-iec-outlets-smartslot-extended-runtime-w-rail-kit\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page — SRT3000RMXLI\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/SPD_JGNY-9NNEDA_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Smart-UPS On-Line SRT2200\/SRT3000 Tower \u0026amp; Rack-Mount 2U installation guide (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/SPD_JGNY-9LPDQJ_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Smart-UPS On-Line SRT user guide \/ operation manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/SPD_VAGL-B3T8YG_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Smart-UPS On-Line SRT 1 kVA - 10 kVA 230V brochure (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eLinks open on Schneider Electric's official document servers.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRT3000RMXLI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 3,000 VA and 2,700 W rating, and how do I size the SRT3000RMXLI?\u003c\/strong\u003e\u003cbr\u003eVA is apparent power and W is real power; equipment nameplates and PSU ratings are quoted in watts, and watts is the figure that limits you. Add up the real draw of everything you want on battery and keep the total below 2,700 W. Sizing to about 70-80% of that leaves headroom for inrush and for future additions, and gives noticeably longer runtime.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long will the SRT3000RMXLI run on battery?\u003c\/strong\u003e\u003cbr\u003eSchneider publishes 11.8 minutes at half load (1,350 W) and 4.0 minutes at full load (2,700 W) on the internal battery. Runtime is not linear with load — halving the load more than doubles the runtime. For longer autonomy, add SRT96BP or SRT96RMBP external battery packs; up to ten can be recognised by the UPS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the SRT3000RMXLI produce a sine wave output, and will it work with an active-PFC power supply?\u003c\/strong\u003e\u003cbr\u003eSchneider's datasheet for the SRT3000RMXLI states a sine wave output waveform, and the unit is an on-line double-conversion design, so the load is fed from the inverter continuously. That is the output type active-PFC server and workstation power supplies expect — unlike the step-approximated output of many entry-level line-interactive and standby UPS units, which some active-PFC supplies reject.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do the XLI and RMXLI suffixes mean?\u003c\/strong\u003e\u003cbr\u003eThey are genuinely different builds, not packaging variants. XLI is the tower orientation supplied without a rail kit; RMXLI is the rackmount 2U build supplied with the rail kit included. Both are 230V international models with extended-runtime capability. Schneider also produces XLT, XLW and -NC (network card) variants of the SRT family that SourceIT does not stock in this band — check the part number carefully against your tender.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich replacement battery does the SRT3000RMXLI take, and can I change it myself?\u003c\/strong\u003e\u003cbr\u003eThe SRT3000RMXLI uses the APCRBC152 replacement battery cartridge. APC designs the SRT battery modules to be user-replaceable, and the front bezel comes off without tools. Plan on replacement every three to five years; heat is the main determinant, so a cabinet that runs hot will shorten cartridge life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much rack space does the SRT3000RMXLI need, and is the rail kit included?\u003c\/strong\u003e\u003cbr\u003eIt occupies 2U (85 mm) in a standard 19-inch cabinet and the rail kit is included in the box. Chassis dimensions are 85 mm (H) x 432 mm (W) x 635 mm (D) — check your cabinet depth, and allow for cable bend radius behind the unit. Net weight is 31.3 kg, so mount it in the lower part of the rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I monitor the SRT3000RMXLI over the network?\u003c\/strong\u003e\u003cbr\u003eNot out of the box — the SmartSlot ships empty. Fit an \u003ca href=\"\/products\/apc-ups-network-management-card-3-ap9640\" target=\"_blank\" rel=\"noopener\"\u003eAP9640\u003c\/a\u003e or \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\" target=\"_blank\" rel=\"noopener\"\u003eAP9641\u003c\/a\u003e Network Management Card 3 for SNMP, HTTPS, email alerting and EcoStruxure IT integration. For a single directly-attached host, the built-in USB or serial port with APC PowerChute is sufficient and costs nothing extra.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the SRT3000RMXLI compare with the SRT2200RMXLI?\u003c\/strong\u003e\u003cbr\u003eBoth are on-line double-conversion SRT units on the same platform. The SRT3000RMXLI is rated 3,000 VA \/ 2,700 W and the SRT2200RMXLI is rated 2,200 VA \/ 1,980 W. They share the same outlet configuration. If your load is close to the boundary, take the larger unit — runtime and battery life both improve when the UPS is not run near its ceiling. See \u003ca href=\"\/products\/apc-smart-ups-srt-2200va-rm-230v-srt2200rmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT2200RMXLI\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the SRT3000RMXLI covered by warranty in Singapore?\u003c\/strong\u003e\u003cbr\u003eYes. Every APC SRT3000RMXLI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRT3000RMXLI with a 3 years UPS electronics \/ 2 years battery manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bnygg_h0bdg\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43073477542052,"sku":"SRT3000RMXLI","price":3875.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_7a239a86-1d77-4b31-be0b-14c602557900.jpg?v=1789721440"},{"product_id":"apc-rack-ats-230v-32a-iec-309-in-16-c13-2-c19-out-ap4424","title":"APC NetShelter Rack ATS 2U 32A 230V, IEC 309 In, 16 C13 2 C19 Out","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Rack ATS 2U 32A 230V, 2 IEC 309 In, 16 C13 2 C19 Out (AP4424A) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e32 A Dual-Source Power for a Fully Populated Rack\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Rack ATS AP4424A is the largest of the three 230 V Rack ATS models, rated 7,400 VA at 32 A. Two IEC 60309 32 A inputs connect it to two independent feeds, and eighteen outlets - sixteen C13 and two C19 - distribute that capacity across a densely populated rack of servers, storage and network equipment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eA 2U Chassis, Not 1U - Budget the Space\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUnlike the 10 A and 16 A models, the AP4424A occupies 2U at 88.1 mm high, 431.8 mm wide and 236.2 mm deep, and the correct 2U bracket kit ships with it. It is easy to assume this model matches its 1U siblings; Schneider's own product name and data sheet both confirm 2U, so plan two rack units for it.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFast Transfer, Selectable Sensitivity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTransfer between sources completes in 10 ms maximum on the high sensitivity setting and 12 ms on low, inside the ride-through of a normal server power supply. Source preference, sensitivity and up to three voltage transfer ranges are selectable from the front panel or the Web UI, and the break-before-make relay design allows the two sources to be up to 180 degrees out of phase.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eNetwork Management Card 3 as Standard\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AP4424A is a fifth-generation NetShelter Rack ATS with Schneider's Network Management Card 3 integrated and field-replaceable: Gigabit Ethernet, a secure Web UI over HTTP\/HTTPS, SSH, SNMP v1 and v3, Modbus TCP and EcoStruxure IT integration, a colour LCD showing load in amps, the state of both sources, the preferred source and alarms, a Universal I\/O port for an AP9335T or AP9335TH sensor, and Link A\/B ports for sharing one IP address across up to 32 units. For a Singapore server room running on 230 V mains and exposed to PUB-side voltage dips, that combination of dual-feed hardware and remote visibility is what turns a single-corded rack into a resilient one.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP4424A Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC Netshelter Rack Automatic Transfer Switch, 2U, 32A, 230V, 2 IEC 309 IN, 16 C13, 2 C19 OUT, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP4424A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Rack ATS, fifth generation (AP44XXA series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRack-mount Automatic Transfer Switch (ATS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e2U, 19-inch rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric); 5-year extended warranty available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connections\u003c\/td\u003e\n\u003ctd\u003eTwo (2) IEC 60309 32 A 2P+E inputs (Source A and Source B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e207 to 253 V (±10% of nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Current\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003ctd\u003eInbuilt (as printed by Schneider Electric); breaker rating and outlet bank split not published - ask us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Cord Length\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this model - ask us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eSixteen (16) IEC 60320 C13 and two (2) IEC 60320 C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Outlet\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider Electric for this model - ask us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Capacity\u003c\/td\u003e\n\u003ctd\u003e7,400 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum (high sensitivity); 12 ms maximum (low sensitivity); typical total transfer 8 to 12 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Technology\u003c\/td\u003e\n\u003ctd\u003eBreak-before-make relay switching; sources may be up to 180 degrees out of phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunications \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management Card\u003c\/td\u003e\n\u003ctd\u003eNetwork Management Card 3 (NMC3) integrated as standard; the NMC\/display module is field-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Port\u003c\/td\u003e\n\u003ctd\u003eGigabit Ethernet (10\/100\/1000) with link status LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interfaces\u003c\/td\u003e\n\u003ctd\u003eWeb UI (HTTP\/HTTPS), Command Line Interface (SSH\/SCP, Telnet), SNMP v1 and v3 with traps, Modbus TCP, FTP, Syslog, e-mail notification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Platform\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure IT compatible (alerts and control for one or many ATS units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Port Sharing\u003c\/td\u003e\n\u003ctd\u003eLink A and Link B ports: up to 32 AP44XXA Rack ATS units share one network connection and one IP address; one unit acts as host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003eMicro-USB for local CLI access (cable not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003eUSB-A for firmware upgrade from a USB drive and for the optional APC AP9834 Wi-Fi USB device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Sensor Port\u003c\/td\u003e\n\u003ctd\u003eUniversal I\/O port for the optional AP9335T temperature sensor or AP9335TH temperature\/humidity sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Display\u003c\/td\u003e\n\u003ctd\u003eColour LCD rotating through four default screens: Source A and B voltage and frequency, load per bank and total load in amps, alarm status, preferred source; Home\/Down\/Select buttons; backlight off after 10 minutes of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource Preference\u003c\/td\u003e\n\u003ctd\u003eSelectable - Source A, Source B, or no preference, from the front panel or remotely\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Sensitivity\u003c\/td\u003e\n\u003ctd\u003eSelectable high or low; up to three configurable transfer ranges (one active at a time) and a frequency deviation setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcurrent Users\u003c\/td\u003e\n\u003ctd\u003eUp to four users logged in simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware\u003c\/td\u003e\n\u003ctd\u003eFlash-upgradeable over the network or from a USB drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e88.1 x 431.8 x 236.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e6.94 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e9.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 15,240 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e210 x 584 x 356 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards (as printed by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003eEN 55022 Class A; FCC Part 15 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS \/ REACh\u003c\/td\u003e\n\u003ctd\u003eEU RoHS compliant; REACh declaration available from Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Load Planning\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Sixteen IEC C13 outlets take standard C14 equipment cords. Two IEC C19 outlets take C20 cords for blade chassis, storage shelves and large core switches. Eighteen outlets and 7,400 VA is enough for a fully populated rack, which is the point of this model over its 10 A and 16 A siblings, the \u003ca href=\"\/products\/apc-rack-ats-230v-10a-c14-in-12-c13-out\"\u003eAP4421A\u003c\/a\u003e and \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423A\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLoad planning and breakers.\u003c\/strong\u003e Maximum capacity is 7,400 VA at 32 A. Schneider lists an inbuilt circuit breaker for this model but does not publish its rating or how the outlets are split between banks, so we do not print those figures - ask us and we will confirm against the current data sheet before you plan the load. Remember that in a failover a single source carries everything, so both upstream feeds must be rated for the full 32 A.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRack fit - this one is 2U.\u003c\/strong\u003e 88.1 mm high, 431.8 mm wide, 236.2 mm deep, and the 2U rack-mount bracket kit ships with it. The AP4421A and AP4423A are 1U; the AP4424A is not. If you are replacing a 1U transfer switch, check you have the extra rack unit free before ordering.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeeding it.\u003c\/strong\u003e Both inputs are IEC 60309 32 A 2P+E, so you need two 32 A IEC 60309 (commando) outlets on two genuinely independent circuits. This is a fixed electrical installation, not something you plug into a wall socket; budget for an electrician if those outlets are not already in the rack. Both feeds must be independent for the redundancy to be meaningful.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eManagement.\u003c\/strong\u003e The AP4424A carries Schneider's Network Management Card 3 as standard - there is no SmartSlot to populate and no card to buy. You get a Gigabit Ethernet port, a secure Web UI over HTTP\/HTTPS, a CLI over SSH, SNMP v1 and v3 with traps, Modbus TCP for a building management system, Syslog and e-mail alerts, and EcoStruxure IT integration. The NMC\/display module can be swapped in the field, so a damaged card is a spare-part exchange rather than a whole-unit return. The micro-USB console cable is not in the box.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental monitoring.\u003c\/strong\u003e The Universal I\/O port accepts the optional AP9335T temperature sensor or the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH temperature and humidity sensor\u003c\/a\u003e, so a comms cabinet with no other monitoring can report rack temperature through the same IP address as its power switching. Thresholds and alarms are set in the same Web UI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMany units, one IP.\u003c\/strong\u003e With Link A and Link B on the front panel, up to 32 AP44XXA-series Rack ATS units can be chained so that one network connection serves them all. One unit is the host; the rest appear under it in the Web UI and in SNMP. \u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; NetShelter Rack ATS Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC NetShelter Rack ATS (AP4424A)\u003c\/li\u003e\n\u003cli\u003e2U rack-mount bracket kit\u003c\/li\u003e\n\u003cli\u003ePhillips screws (10-32 x 0.5 in), cage nuts and clip-on nuts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInput connection: the AP4424A connects to two 32 A IEC 60309 2P+E supplies; whether input cords are captive on this model is not published by Schneider Electric, so ask us to confirm before you order plugs. A micro-USB cable for the console port is not included; any standard micro-USB data cable will do. Front and rear rail segments and a cord retention bracket are optional accessories and are not in the box.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eNetShelter Rack ATS Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-10a-c14-in-12-c13-out\"\u003eAP4421A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 10 A, 2,000 VA\u003c\/td\u003e\n\u003ctd\u003e2 x IEC C14 inlets\u003c\/td\u003e\n\u003ctd\u003e(12) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3,700 VA\u003c\/td\u003e\n\u003ctd\u003e2 x IEC C20 inlets\u003c\/td\u003e\n\u003ctd\u003e(8) C13, (1) C19\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP4424A (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 32 A, 7,400 VA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2 x IEC 60309 32 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(16) C13, (2) C19\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335TH\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAPC Temperature \u0026amp; Humidity Sensor\u003c\/a\u003e - plugs into the Universal I\/O port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335T\u003c\/td\u003e\n\u003ctd\u003eAPC Temperature Sensor - plugs into the Universal I\/O port; ask us for availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9834\u003c\/td\u003e\n\u003ctd\u003eAPC Wi-Fi USB device for cable-free setup and management via the USB-A port; ask us for availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eSchneider Electric hosts the official documentation for the AP44XXA-series Rack ATS. The links below are the document landing pages and product page that resolve to the correct part number. Links open in a new tab.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct overview and specifications\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-91721_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eNetShelter Rack ATS AP4424A Overview and Specifications (990-91721_EN)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-91718_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eRack ATS with Network Management Card 3 User Guide AP44XXA (990-91718_EN)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical brochure\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/sg\/en\/download\/document\/AP44xxA_Technical_Brochure\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC NetShelter Rack ATS Fifth Generation AP44xxA Series Technical Brochure\u003c\/a\u003e — Singapore site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric product page\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.se.com\/us\/en\/product\/AP4424A\/apc-netshelter-rack-automatic-transfer-switch-2u-32a-230v-2-iec-309-in-16-c13-2-c19-out-50-60-hz\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC AP4424A on se.com\u003c\/a\u003e — Schneider Electric US site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eSchneider's own datasheet and user manual download links redirect to a document host that has repeatedly served the wrong model's file, so we do not publish those links here rather than risk sending you the wrong specification. Email \u003cstrong\u003esales@sourceit.com.sg\u003c\/strong\u003e quoting \u003cstrong\u003eAP4424A\u003c\/strong\u003e and we will send you the current PDF datasheet and user guide directly.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP4424A\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eIs the AP4424A 1U or 2U?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2U. Schneider's product name, technical brochure and data sheet all give 2U and a height of 88.1 mm, and the 2U bracket kit ships in the box. Third-party listings sometimes show 1U for this part, so it is worth checking. Its smaller siblings, the \u003ca href=\"\/products\/apc-rack-ats-230v-10a-c14-in-12-c13-out\"\u003eAP4421A\u003c\/a\u003e and \u003ca href=\"\/products\/apc-rack-ats-230v-16a-c20-in-8-c13-1-c19-out\"\u003eAP4423A\u003c\/a\u003e, are the 1U models.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat input supply does it need?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTwo independent 32 A IEC 60309 2P+E (commando) circuits. The outlets themselves are a fixed electrical installation - this is not a plug-into-the-wall product. Both circuits must be able to carry the full 32 A on their own, because in a failover one of them will.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes the AP4424A have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider states this plainly in the AP44XXA user guide (990-91718): the Rack ATS does not include power surge protection, and it recommends connecting each Rack ATS source to a double-conversion on-line UPS. Claims of surge suppression against this part are incorrect. If surge and dip protection is what you actually need, an on-line UPS such as the Smart-UPS SRT range in front of the ATS is the right answer, and it also gives the ATS a genuinely independent second source.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs network management built in, or do I need to buy a card?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBuilt in. The AP4424A ships with Network Management Card 3 integrated - Gigabit Ethernet, Web UI over HTTP\/HTTPS, SSH, SNMP v1 and v3, Modbus TCP and EcoStruxure IT support are all standard. You do not buy a card for it. If the module is ever damaged it can be replaced in the field rather than sending the whole switch away.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan it monitor rack temperature and humidity?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes, with an optional sensor. Plug an AP9335T (temperature) or \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH (temperature and humidity)\u003c\/a\u003e into the Universal I\/O port and the readings, thresholds and alarms appear in the same Web UI and SNMP tree as the power data. No NetBotz appliance is needed for a single-cabinet site.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat does \"manage up to 32 ATS from one IP address\" mean in practice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEach AP44XXA-series unit has Link A and Link B ports. Chain up to 32 units through those ports, connect only the host unit to your network, and every unit in the group is visible and configurable through that one IP address. It saves a switch port and an address per cabinet and keeps the whole estate under one login.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow fast does it transfer, and will my servers notice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA maximum of 10 ms on the high sensitivity setting, 12 ms on low sensitivity, with Schneider quoting a typical total transfer of 8 to 12 ms. That is inside the hold-up time of a normal server or network power supply, so equipment generally rides through without restarting. High sensitivity reacts sooner to a marginal source; low sensitivity tolerates more deviation before acting, which is useful when a generator feed would otherwise make the unit transfer more often than you want. The two sources may be up to 180 degrees out of phase.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does the AP4424A differ from the AP4424 it replaces?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe electrical side is unchanged: same 32 A, 230 V, 7,400 VA rating, same inlet type and the same outlet configuration, so the AP4424A drops into an existing AP4424 installation without rewiring. What Schneider changed is the management module. The AP4424A moves from Network Management Card 2 to Network Management Card 3, and that card and its display are now field-replaceable. It adds a Universal I\/O port for an AP9335T or AP9335TH sensor, Link A and Link B ports for Network Port Sharing of up to 32 units on one IP address, Gigabit Ethernet in place of 10\/100, a colour LCD, a micro-USB console port instead of the old RJ12 serial lead, a USB-A port for firmware upgrade and the AP9834 Wi-Fi device, Modbus TCP, updated security (secured interfaces and a stricter password policy) and EcoStruxure IT integration. The standard warranty stays at 2 years.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Rack ATS AP4424A sold by SourceIT comes with local Singapore warranty and a GST invoice; APC by Schneider Electric backs the AP4424A with a 2-year manufacturer warranty, and a 5-year extended warranty is offered by Schneider - ask us to quote it with the unit.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43073531019428,"sku":"AP4424A","price":2470.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_26f438f9-eb8d-4ae7-8f88-35ecd954d783.jpg?v=1789701468"},{"product_id":"apc-smart-ups-on-line-1000va-1000w-rackmount-2u-230v-srt1000rmxli","title":"APC Smart-UPS On-Line 1000VA Rackmount 2U","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Smart-UPS On-Line 1000VA Rackmount 2U (SRT1000RMXLI) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eDouble-Conversion On-Line Power Protection for Singapore's 230V Mains\u003c\/h3\u003e\n\u003cp\u003eThe APC Smart-UPS SRT 1 kVA (SRT1000RMXLI) is an on-line, double-conversion UPS: incoming mains is rectified to DC and regenerated as a clean sine wave output, so the load is fed from the inverter continuously rather than being switched over when the supply fails. On Singapore's 230V \/ 50Hz supply that matters most during the afternoon storm season, when PUB grid dips, brownouts and momentary interruptions are common enough to reset a server or corrupt a database write. Schneider specifies the SRT1000RMXLI to accept an input range of 176-275 V at full load; 100-275 V at 40% load at 40-70Hz auto-sensing, so it rides through sag and swell without drawing on the battery.\u003c\/p\u003e\n\u003ch3\u003e1,000 VA \/ 1,000 W of Sine Wave Output on (6) C13 Outlets\u003c\/h3\u003e\n\u003cp\u003eSchneider rates the SRT1000RMXLI at 1,000 VA \/ 1,000 W with a nominal 230V AC single-phase output at 50\/60Hz (±3Hz, synchronised to mains) and a sine wave output waveform. The unity power factor means the watt rating equals the VA rating, so you get the full 1,000 W to a modern active-PFC server or network load rather than the derated figure typical of line-interactive units. Outlets are (6) IEC 60320 C13.\u003c\/p\u003e\n\u003ch3\u003eRuntime and Extended Runtime with SRT Battery Packs\u003c\/h3\u003e\n\u003cp\u003eSchneider's published runtime for the SRT1000RMXLI on its internal battery is 21.5 minutes at half load (500 W) and 8.4 minutes at full load (1,000 W) — enough to ride out a short outage or to shut a rack down cleanly. Where you need longer, the SRT1000RMXLI accepts external battery packs: the SRT48RMBP matches this unit's 48V battery bus, the UPS will recognise as many as ten packs, and the internal cartridge is the APCRBC155. Battery service life in a Singapore comms cabinet depends heavily on ambient temperature, so keep the room cool and dry; Schneider rates the unit for 0-40°C operation at 0-95% non-condensing humidity.\u003c\/p\u003e\n\u003ch3\u003e2U Rack-Ready, Rail Kit Included\u003c\/h3\u003e\n\u003cp\u003eThe SRT1000RMXLI occupies 2U (85 mm) of rack height in a 85 mm (H) x 432 mm (W) x 505 mm (D) chassis and ships \u003cstrong\u003ewith the rail kit included\u003c\/strong\u003e, so it goes straight into a standard 19-inch cabinet without a separate accessory order. Net weight is 21 kg — plan the lift and mount it low in the cabinet. The same chassis converts to tower orientation if the deployment changes. Check your cabinet depth against the 505 mm (D) figure before ordering.\u003c\/p\u003e\n\u003ch3\u003eManagement, Monitoring and Local Singapore Supply\u003c\/h3\u003e\n\u003cp\u003eSerial (RJ45) and USB (Type A) interface ports are built in, together with an available SmartSlot for an APC Network Management Card 3 (AP9640 or AP9641) where you need SNMP, web access or EcoStruxure IT monitoring, and an emergency power off (EPO) connection. A multi-function LCD console gives status and configuration at the unit. Audible noise is rated at 50 dBA. SourceIT supplies the SRT1000RMXLI from Singapore stock with a GST invoice and local warranty support — no overseas RMA, no import paperwork.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SRT1000RMXLI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSRT1000RMXLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS On-Line, 1000VA\/1000W, Rackmount 2U, 230V, 6x C13 IEC outlets, SmartSlot, Extended runtime, W\/ rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPS Type \/ Topology\u003c\/td\u003e\n\u003ctd\u003eOn-Line, double conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eRackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN \/ UPC\u003c\/td\u003e\n\u003ctd\u003e731304273431\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e1,000 VA \/ 1,000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±3 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003e(6) IEC 60320 C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e176-275 V at full load; 100-275 V at 40% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e40-70 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14, BS 1363 (British) or CEE 7\/7 (Schuko)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed, maintenance-free, valve-regulated lead-acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC155\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e3 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Runtime at Half Load\u003c\/td\u003e\n\u003ctd\u003e21.5 minutes (500 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Runtime at Full Load\u003c\/td\u003e\n\u003ctd\u003e8.4 minutes (1,000 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible External Battery Packs\u003c\/td\u003e\n\u003ctd\u003eSRT48BP (tower) \/ SRT48RMBP (rackmount), up to 10 packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Ports\u003c\/td\u003e\n\u003ctd\u003eSerial (RJ45), USB (Type A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmartSlot\u003c\/td\u003e\n\u003ctd\u003eYes — accepts APC Network Management Card 3 (AP9640 \/ AP9641) and other SmartSlot accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management Card\u003c\/td\u003e\n\u003ctd\u003eNot included — SmartSlot is supplied empty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes (NO\/NC connections)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Panel\u003c\/td\u003e\n\u003ctd\u003eMulti-function LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e85 mm (H) x 432 mm (W) x 505 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e21 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e2U (85 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRail Kit\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcoustic Level\u003c\/td\u003e\n\u003ctd\u003e50 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 3,000 m (0 to 10,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards \u0026amp; Marks\u003c\/td\u003e\n\u003ctd\u003eCE Mark, EN\/IEC 62040-1:2019\/A11:2021, EN\/IEC 62040-2:2018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e3 years UPS electronics \/ 2 years battery (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003e2 years, supplied and supported by SourceIT Pte Ltd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug in.\u003c\/strong\u003e The SRT1000RMXLI provides (6) IEC 60320 C13. All outlets are battery-backed. Total the real power draw (watts) of the equipment you intend to protect and keep it below the 1,000 W rating — runtime falls sharply as load rises, as the figures below show.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal battery, half load (500 W)\u003c\/td\u003e\n\u003ctd\u003e21.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal battery, full load (1,000 W)\u003c\/td\u003e\n\u003ctd\u003e8.4 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRuntime depends on load.\u003c\/strong\u003e These are Schneider's published estimates for a healthy battery at 25°C; real runtime varies with load, battery age and ambient temperature, which in an unconditioned Singapore comms cabinet can shorten battery life considerably.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtended runtime.\u003c\/strong\u003e Connect SRT48BP (tower) or SRT48RMBP (rackmount) external battery packs on the 48V battery bus. The UPS will recognise as many as ten packs. Recharge time increases with each pack added.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e Occupies 2U (85 mm) and ships with the rail kit included; chassis depth is 505 mm (D).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput and circuit.\u003c\/strong\u003e The SRT1000RMXLI input is IEC 60320 C14, BS 1363 (British) or CEE 7\/7 (Schuko). At 1,000 W a dedicated 13A or 16A supply is the sensible provision; confirm the circuit with your electrician before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork management.\u003c\/strong\u003e The SmartSlot is supplied empty. Fit an \u003ca href=\"\/products\/apc-ups-network-management-card-3-ap9640\" target=\"_blank\" rel=\"noopener\"\u003eAP9640\u003c\/a\u003e or \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\" target=\"_blank\" rel=\"noopener\"\u003eAP9641\u003c\/a\u003e Network Management Card 3 for SNMP, HTTPS and EcoStruxure IT monitoring; the AP9641 adds environmental monitoring inputs for the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\" target=\"_blank\" rel=\"noopener\"\u003eAP9335TH\u003c\/a\u003e sensor. Serial and USB are built in for direct PowerChute connection to a single host.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Smart-UPS SRT Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eIn the box:\u003c\/strong\u003e UPS unit, rail kit and rack mounting brackets, battery cable\/connector hardware, user documentation and warranty card. Exact contents are listed in the APC user guide linked in the Downloads section below.\u003c\/p\u003e\n\u003ch4\u003eSmart-UPS SRT 1-3 kVA range at SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-1000va-230v-srt1000xli\" target=\"_blank\" rel=\"noopener\"\u003eSRT1000XLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 VA \/ 1,000 W · Tower · no rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-1500va-230v-srt1500xli\" target=\"_blank\" rel=\"noopener\"\u003eSRT1500XLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1,500 VA \/ 1,500 W · Tower · no rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-2200va-230v-srt2200xli\" target=\"_blank\" rel=\"noopener\"\u003eSRT2200XLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2,200 VA \/ 1,980 W · Tower · no rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-3000va-230v-srt3000xli\" target=\"_blank\" rel=\"noopener\"\u003eSRT3000XLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000 VA \/ 2,700 W · Tower · no rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSRT1000RMXLI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 VA \/ 1,000 W · Rackmount 2U · rail kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-on-line-1500va-1500w-rackmount-2u-230v-srt1500rmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT1500RMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1,500 VA \/ 1,500 W · Rackmount 2U · rail kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-2200va-rm-230v-srt2200rmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT2200RMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2,200 VA \/ 1,980 W · Rackmount 2U · rail kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-on-line-3kva-rackmount-2u-230v-8x-c13-2x-c19-iec-srt3000rmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT3000RMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3,000 VA \/ 2,700 W · Rackmount 2U · rail kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMatching external battery packs\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-48v-1kva-1-5kva-battery-pack-srt48bp\" target=\"_blank\" rel=\"noopener\"\u003eSRT48BP\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e48 V, SRT 1 kVA \/ 1.5 kVA · Tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-48v-1kva-1-5kva-rm-battery-pack-srt48rmbp\" target=\"_blank\" rel=\"noopener\"\u003eSRT48RMBP\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e48 V, SRT 1 kVA \/ 1.5 kVA · Rackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eReplacement battery cartridge\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003eAPCRBC155\u003c\/td\u003e\n\u003ctd\u003eInternal replacement battery cartridge for the SRT1000RMXLI\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch4\u003eNetwork management and SmartSlot accessories\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-ap9640\" target=\"_blank\" rel=\"noopener\"\u003eAP9640\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eUPS Network Management Card 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\" target=\"_blank\" rel=\"noopener\"\u003eAP9641\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eUPS Network Management Card 3 with Environmental Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-dry-contact-i-o-smartslot-card-ap9613\" target=\"_blank\" rel=\"noopener\"\u003eAP9613\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eDry Contact I\/O SmartSlot Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-temperature-humidity-sensor\" target=\"_blank\" rel=\"noopener\"\u003eAP9335TH\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature \u0026amp; Humidity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/SRT1000RMXLI\/apc-smartups-online-1000va-1000w-rackmount-2u-230v-6x-c13-iec-outlets-smartslot-extended-runtime-w-rail-kit\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page — SRT1000RMXLI\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/sa\/en\/download\/document\/SPD_JGNY-ASG8LT_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Smart-UPS On-Line SRT user guide \/ operation manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/SPD_VAGL-B3T8YG_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Smart-UPS On-Line SRT 1 kVA - 10 kVA 230V brochure (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eLinks open on Schneider Electric's official document servers.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SRT1000RMXLI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 1,000 VA and 1,000 W rating, and how do I size the SRT1000RMXLI?\u003c\/strong\u003e\u003cbr\u003eVA is apparent power and W is real power; equipment nameplates and PSU ratings are quoted in watts, and watts is the figure that limits you. Add up the real draw of everything you want on battery and keep the total below 1,000 W. Sizing to about 70-80% of that leaves headroom for inrush and for future additions, and gives noticeably longer runtime.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long will the SRT1000RMXLI run on battery?\u003c\/strong\u003e\u003cbr\u003eSchneider publishes 21.5 minutes at half load (500 W) and 8.4 minutes at full load (1,000 W) on the internal battery. Runtime is not linear with load — halving the load more than doubles the runtime. For longer autonomy, add SRT48BP or SRT48RMBP external battery packs; up to ten can be recognised by the UPS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the SRT1000RMXLI produce a sine wave output, and will it work with an active-PFC power supply?\u003c\/strong\u003e\u003cbr\u003eSchneider's datasheet for the SRT1000RMXLI states a sine wave output waveform, and the unit is an on-line double-conversion design, so the load is fed from the inverter continuously. That is the output type active-PFC server and workstation power supplies expect — unlike the step-approximated output of many entry-level line-interactive and standby UPS units, which some active-PFC supplies reject.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do the XLI and RMXLI suffixes mean?\u003c\/strong\u003e\u003cbr\u003eThey are genuinely different builds, not packaging variants. XLI is the tower orientation supplied without a rail kit; RMXLI is the rackmount 2U build supplied with the rail kit included. Both are 230V international models with extended-runtime capability. Schneider also produces XLT, XLW and -NC (network card) variants of the SRT family that SourceIT does not stock in this band — check the part number carefully against your tender.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich replacement battery does the SRT1000RMXLI take, and can I change it myself?\u003c\/strong\u003e\u003cbr\u003eThe SRT1000RMXLI uses the APCRBC155 replacement battery cartridge. APC designs the SRT battery modules to be user-replaceable, and the front bezel comes off without tools. Plan on replacement every three to five years; heat is the main determinant, so a cabinet that runs hot will shorten cartridge life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much rack space does the SRT1000RMXLI need, and is the rail kit included?\u003c\/strong\u003e\u003cbr\u003eIt occupies 2U (85 mm) in a standard 19-inch cabinet and the rail kit is included in the box. Chassis dimensions are 85 mm (H) x 432 mm (W) x 505 mm (D) — check your cabinet depth, and allow for cable bend radius behind the unit. Net weight is 21 kg, so mount it in the lower part of the rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I monitor the SRT1000RMXLI over the network?\u003c\/strong\u003e\u003cbr\u003eNot out of the box — the SmartSlot ships empty. Fit an \u003ca href=\"\/products\/apc-ups-network-management-card-3-ap9640\" target=\"_blank\" rel=\"noopener\"\u003eAP9640\u003c\/a\u003e or \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\" target=\"_blank\" rel=\"noopener\"\u003eAP9641\u003c\/a\u003e Network Management Card 3 for SNMP, HTTPS, email alerting and EcoStruxure IT integration. For a single directly-attached host, the built-in USB or serial port with APC PowerChute is sufficient and costs nothing extra.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the SRT1000RMXLI compare with the SRT1500RMXLI?\u003c\/strong\u003e\u003cbr\u003eBoth are on-line double-conversion SRT units on the same platform. The SRT1000RMXLI is rated 1,000 VA \/ 1,000 W and the SRT1500RMXLI is rated 1,500 VA \/ 1,500 W. They share the same outlet configuration. If your load is close to the boundary, take the larger unit — runtime and battery life both improve when the UPS is not run near its ceiling. See \u003ca href=\"\/products\/apc-smart-ups-on-line-1500va-1500w-rackmount-2u-230v-srt1500rmxli\" target=\"_blank\" rel=\"noopener\"\u003eSRT1500RMXLI\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the SRT1000RMXLI covered by warranty in Singapore?\u003c\/strong\u003e\u003cbr\u003eYes. Every APC SRT1000RMXLI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SRT1000RMXLI with a 3 years UPS electronics \/ 2 years battery manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bnygg_h0bdg\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43073556578468,"sku":"SRT1000RMXLI","price":2005.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_31eda2e5-5864-4f51-b6ae-6c90d910a3e6.jpg?v=1789720366"},{"product_id":"apc-smart-ups-x-battery-pack-for-extended-runtime-smx120rmbp2u","title":"APC Smart-UPS X Battery Pack, Extended Runtime","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Smart-UPS X External Battery Pack, Rack\/Tower 2U, 120 V DC with Rail Kit (SMX120RMBP2U) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003e1200 VAh of Extended Runtime for 2U Rack Smart-UPS X\u003c\/h3\u003e\n\u003cp\u003eThe APC SMX120RMBP2U is the 120 V DC external battery pack matched to the 2U rackmount Smart-UPS X models above 2 kVA. It holds 1200 VAh across ten 12 V blocks per string and two replacement cartridges, and it ships with a rail kit as part of the product itself. In a Singapore data cabinet running on 230 V\/50 Hz mains, this is the difference between riding out a brownout and running a full graceful shutdown of everything in the rack.\u003c\/p\u003e\n\u003ch3\u003eBuilt for the 2U Chassis — 667 mm Deep, Rails Included\u003c\/h3\u003e\n\u003cp\u003eThis pack is 85 mm high (2U), 432 mm wide and 667 mm deep. That depth is the number to check before you order: it needs a genuinely deep cabinet, and it is 177 mm deeper than the 48 V SMX48RMBP2U. At 56.36 kg net it is also heavy enough to matter for rack load planning and for the two people you will want on the install.\u003c\/p\u003e\n\u003ch3\u003eUp to Ten Packs, Managed by the UPS\u003c\/h3\u003e\n\u003cp\u003eThe Smart-UPS X display will recognise as many as ten SMX120RMBP2U packs connected to a single UPS. The UPS handles charging and runtime calculation for the whole string, so front-panel runtime and PowerChute shutdown timing remain correct as you scale. Adding packs later is a straightforward upgrade path when a rack grows past its original power budget.\u003c\/p\u003e\n\u003ch3\u003eRated for a Singapore Comms Room\u003c\/h3\u003e\n\u003cp\u003eThe pack is specified for 0–40 °C operation and 0–95% relative humidity, which covers a Singapore comms cabinet comfortably — though as with all sealed lead-acid, cooler is kinder and battery life shortens in a hot cupboard. It is Green Premium, mercury free, REACh SVHC free and RoHS pro-active compliant. SourceIT supplies it with a GST invoice and local Singapore warranty support.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SMX120RMBP2U Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSMX120RMBP2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS X External Battery Pack, Rack\/Tower 2U, 120 Vdc, with rail kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExternal battery pack (XLBP) for APC Smart-UPS X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eRack\/Tower convertible, 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBattery Specifications\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Battery Voltage\u003c\/td\u003e\n\u003ctd\u003e120 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStored Energy\u003c\/td\u003e\n\u003ctd\u003e1200 VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLead-acid (Schneider Electric data sheet wording)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Blocks per String\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Cartridge Quantity\u003c\/td\u003e\n\u003ctd\u003e2 cartridges per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Packs per UPS\u003c\/td\u003e\n\u003ctd\u003eUp to ten\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e85 × 432 × 667 mm (3.35 × 17.01 × 26.26 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e56.36 kg (124.25 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e63.64 kg (140.30 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e86.9 × 59.6 × 24.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−15 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 3,048 m (0 to 10,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Compliance\u003c\/td\u003e\n\u003ctd\u003eGreen Premium; mercury free; REACh free of SVHC; EU RoHS pro-active compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eExternal battery pack, rail kit, rack-mounting brackets, installation guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eSpecifications We Have Not Published\u003c\/h3\u003e\n\u003cp\u003eSchneider Electric does not publish a recharge time or a safety-agency certification list for this pack, and does not describe it as hot-swappable — so those are not claimed here. The replacement cartridge part number is widely quoted in the trade as APCRBC118 but we could not confirm it in a Schneider-authored document, so we have left it out rather than risk sending you the wrong cartridge; ask us and we will confirm against the label on your unit. Barcode data on this SKU is inconsistent between sources. Where Schneider Electric does not publish a figure for this exact model, SourceIT leaves it out rather than estimate it from a similar part number.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eThe SMX120RMBP2U is the 120 V pack for the \u003cstrong\u003e2U rackmount\u003c\/strong\u003e Smart-UPS X models above 2 kVA. It is not interchangeable with the 4U \u003ca href=\"\/products\/apc-smart-ups-x-120v-short-depth-ebb\"\u003eSMX120BP\u003c\/a\u003e despite both being 120 V and 1200 VAh — different chassis, different depth, different mounting hardware, different UPS family. The models named in Schneider's 2U rack operation manual are:\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-2200va-rack-tower-lcd-200-240v-smx2200rmhv2u\"\u003eAPC Smart-UPS X 2200VA LCD 200-240V Rack\/Tower\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMX2200RMHV2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-3000va-rack-tower-lcd-200-240v-smx3000rmhv2u\"\u003eAPC Smart-UPS X 3000VA Rack\/Tower LCD 200-240V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMX3000RMHV2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-3000va-rack-tower-lcd-ups-w-network-card-smx3000rmhv2unc\"\u003eAPC Smart-UPS X 3000VA Rack\/Tower LCD UPS with Network Card\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMX3000RMHV2UNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSchneider's manual also lists the 100–127 V 2U models SMX2000RMLV2U, SMX2200RMLV2U, SMX3000RMLV2U, SMX3000RMLV2UNC and SMX3000RMJ2U. Those are low-voltage builds not sold for the Singapore 230 V market and SourceIT does not stock them.\u003c\/p\u003e\n\u003cp\u003eSourceIT also stocks the \u003ca href=\"\/products\/apc-smart-ups-x-2200va-lcd-200-240v-with-network-card-smx2200r2hvnc\"\u003eSMX2200R2HVNC\u003c\/a\u003e, a later 2U 200–240 V build in the same chassis family. It is not named in the manual revision we checked, so please confirm pack compatibility with us before ordering for that model rather than assuming it.\u003c\/p\u003e\n\u003cp\u003eRuntime depends on the connected load and Schneider publishes no runtime table for this pack, so we will not quote a figure. Give us your load in watts and your target runtime and we will size the pack count. The pack has no outlets and no AC input of its own — it is a DC extension of the UPS battery bus, and all load connection, metering and network management stay with the UPS.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Smart-UPS X Battery Pack Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAPC Smart-UPS X External Battery Pack (SMX120RMBP2U)\u003c\/li\u003e\n\u003cli\u003eRail kit\u003c\/li\u003e\n\u003cli\u003eRack-mounting brackets\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSmart-UPS X Battery Pack Ordering Information\u003c\/h3\u003e\n\u003cp\u003eThe Smart-UPS X external battery packs split by battery bus voltage and by chassis. Choose the pack that matches your UPS, not the one that matches your rack:\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-series-external-battery-pack-rack-tower-48v-smx48rmbp2u\"\u003eAPC Smart-UPS X-Series External Battery Pack, Rack\/Tower 2U, 48 V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMX48RMBP2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPC Smart-UPS X External Battery Pack, Rack\/Tower 2U, 120 V DC, with rail kit (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSMX120RMBP2U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-120v-short-depth-ebb\"\u003eAPC Smart-UPS X-Series External Battery Pack, Rack\/Tower 4U, 120 V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMX120BP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCartridges for the matching 2U UPS\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-117-apcrbc117\"\u003eAPC Replacement Battery Cartridge #117 (SMX2200RMHV2U \/ SMX3000RMHV2U)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPCRBC117\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eManagement and monitoring for the UPS\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-ap9640\"\u003eAPC UPS Network Management Card 3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAP9640\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAPC UPS Network Management Card 3 with Environmental Monitoring\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAP9641\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAPC Temperature \u0026amp; Humidity Sensor\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAP9335TH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eFull technical documentation for the APC SMX120RMBP2U is published by Schneider Electric. The official product page below lists the Schneider Electric product data sheet and the Smart-UPS X 2U rack operation manual.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/product\/SMX120RMBP2U\/apc-smartups-x-external-battery-pack-rack-tower-2u-120vdc-w-rail-kit\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric official product page — APC SMX120RMBP2U\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eSchneider Electric serves its datasheet and manual PDFs through a redirecting download service that we cannot link to reliably, so we do not publish a direct PDF link that might break or return the wrong model's document. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with the model number and we will send you the current APC SMX120RMBP2U product data sheet and user manual as PDFs, along with a quotation.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SMX120RMBP2U\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhich UPS models does the SMX120RMBP2U fit?\u003c\/h3\u003e\n\u003cp\u003eIt is the 120 V pack for the 2U rackmount Smart-UPS X models above 2 kVA — in the SourceIT range, the \u003ca href=\"\/products\/apc-smart-ups-x-2200va-rack-tower-lcd-200-240v-smx2200rmhv2u\"\u003eSMX2200RMHV2U\u003c\/a\u003e, \u003ca href=\"\/products\/apc-smart-ups-x-3000va-rack-tower-lcd-200-240v-smx3000rmhv2u\"\u003eSMX3000RMHV2U\u003c\/a\u003e and \u003ca href=\"\/products\/apc-smart-ups-x-3000va-rack-tower-lcd-ups-w-network-card-smx3000rmhv2unc\"\u003eSMX3000RMHV2UNC\u003c\/a\u003e. It does not fit the 48 V 750–1500 VA models.\u003c\/p\u003e\n\u003ch3\u003eCan I use this instead of the SMX120BP? They look the same on paper.\u003c\/h3\u003e\n\u003cp\u003eNo. Both are 120 V and 1200 VAh, but the SMX120RMBP2U is a 2U chassis 667 mm deep for the 2U rack UPS family, while the \u003ca href=\"\/products\/apc-smart-ups-x-120v-short-depth-ebb\"\u003eSMX120BP\u003c\/a\u003e is a 4U chassis 483 mm deep for the 4U tower\/rack family. Different mounting hardware and different UPS models — they are not substitutes.\u003c\/p\u003e\n\u003ch3\u003eHow many packs can I connect?\u003c\/h3\u003e\n\u003cp\u003eUp to ten per UPS. The UPS recognises each one and adjusts its runtime estimate automatically.\u003c\/p\u003e\n\u003ch3\u003eHow much runtime will it add?\u003c\/h3\u003e\n\u003cp\u003eIt depends on your load, and Schneider publishes no runtime table for this pack, so we will not invent one. Tell us your load in watts and the number of minutes you need and we will size it properly.\u003c\/p\u003e\n\u003ch3\u003eDoes the rail kit come with it?\u003c\/h3\u003e\n\u003cp\u003eYes — the rail kit is part of the product, and it is in the official Schneider product name. Rack-mounting brackets and the installation guide are in the carton too.\u003c\/p\u003e\n\u003ch3\u003eWhat do I need to allow for in the rack?\u003c\/h3\u003e\n\u003cp\u003e2U of height, \u003cstrong\u003e667 mm of depth\u003c\/strong\u003e and 56.36 kg per pack. The depth is the usual sticking point — check your cabinet before ordering. Mount battery packs low for stability and confirm the rack's static load rating if you are stacking several.\u003c\/p\u003e\n\u003ch3\u003eIs the warranty valid in Singapore, and do I get a GST invoice?\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC SMX120RMBP2U sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SMX120RMBP2U with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43073581777060,"sku":"SMX120RMBP2U","price":1965.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_74dda5ea-4712-4079-b84c-d2d2a9d534f1.jpg?v=1789720402"},{"product_id":"smart-ups-c-3000va-lcd-230v-smc3000i","title":"APC Smart-UPS C 3000VA LCD 230V","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Smart-UPS C, Line Interactive, 3000VA \/ 2100W, Tower, 230V (SMC3000I) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003e3000 VA \/ 2100 W Sine Wave UPS for Server Rooms and Heavier Office Loads\u003c\/h3\u003e\n\u003cp\u003eThe APC Smart-UPS C SMC3000I is the largest tower in the Smart-UPS C range: 3000 VA and \u003cstrong\u003e2100 W\u003c\/strong\u003e of true sine wave output with Automatic Voltage Regulation. At that rating it comfortably carries a small rack of servers, a storage array, or a full comms cabinet's switching and routing. Output distortion stays under 5% at full load, so active-PFC server power supplies see the clean waveform they are designed for.\u003c\/p\u003e\n\u003ch3\u003eAVR Corrects Singapore Mains Without Cycling the Battery\u003c\/h3\u003e\n\u003cp\u003eSingapore runs on 230 V, 50 Hz mains, and the day-to-day threat to equipment here is rarely a full blackout — it is the sag when a PUB feeder is switched, the brownout during a storm, and the surge that follows. Automatic Voltage Regulation corrects those without touching the battery, which is why an AVR unit's batteries last longer in service than a cheaper standby UPS's do in the same building. The SMC3000I accepts input from 180 to 287 V, adjustable from 170 to 300 V, and holds the output steady across that whole range using the transformer rather than the battery.\u003c\/p\u003e\n\u003ch3\u003eEight C13 Outlets Plus a C19 — All Battery-Backed\u003c\/h3\u003e\n\u003cp\u003eYou get eight IEC C13 outlets and one IEC C19, every one of them on battery backup. The C19 takes a C20-terminated cord for a heavier single load such as a blade chassis or a downstream PDU. The unit is fed through an IEC C20 inlet, and at 3000 VA a dedicated circuit is not optional — plan the electrical work with the install.\u003c\/p\u003e\n\u003ch3\u003eFloor-Standing Tower with Graphic LCD and a Genuine APC Cartridge\u003c\/h3\u003e\n\u003cp\u003eThe SMC3000I is a substantial tower at 435 × 197 × 544 mm and 43 kg net, intended to sit on the floor of a server room or comms cupboard rather than on a desk. The multifunction graphic LCD gives load, runtime and input voltage without a laptop, and the battery is a genuine APC APCRBC150 cartridge, user-replaceable when it reaches end of life. For a rack, the equivalent is the \u003ca href=\"\/products\/apc-smart-ups-c-line-interactive-3kva-rackmount-2u-230v-smc3000rmi2u\"\u003eSMC3000RMI2U\u003c\/a\u003e.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SMC3000I Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSMC3000I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS C, Line Interactive, 3kVA, Tower, 230V, 8x IEC C13 + 1x IEC C19 outlets, USB and Serial communication, AVR, Graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction graphic LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eC-Tick, CE, EAC, GOST, SABS, VDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eOutput\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Distortion\u003c\/td\u003e\n\u003ctd\u003eLess than 5% at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003e(8) IEC 320 C13 + (1) IEC 320 C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e300 Joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInput\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range (mains operation)\u003c\/td\u003e\n\u003ctd\u003e180 to 287 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e170 to 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 320 C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003eAutomatic Voltage Regulation (AVR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBatteries \u0026amp; Runtime\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e3 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Battery Life\u003c\/td\u003e\n\u003ctd\u003e3 to 5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Load\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric publishes no runtime table for this model — contact SourceIT with your load in watts for a sizing estimate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCommunications \u0026amp; Management\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eUSB and serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmartSlot\u003c\/td\u003e\n\u003ctd\u003eNone — an internal network management card cannot be fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Software\u003c\/td\u003e\n\u003ctd\u003eCompatible with APC PowerChute management software for graceful shutdown over USB or serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e435 × 197 × 544 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e43.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e51.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 3,048 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e45 dBA at 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e135 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eSoftware CD, documentation CD, USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eSpecifications We Have Not Published\u003c\/h3\u003e\n\u003cp\u003eSchneider Electric does not publish a transfer time, a battery VAh figure, an input current or a battery bus voltage on the SMC3000I data sheet, so none is stated here. UL and cUL are not on the certification list for this 230 V IEC model and are not claimed. The Smart-UPS C series takes no external battery pack, so no extended-runtime option exists for this model. Where Schneider Electric does not publish a figure for this exact model, SourceIT leaves it out rather than estimate it from a similar part number.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eAll nine outlets — eight IEC C13 and one IEC C19 — are battery-backed. There are no surge-only sockets to work around.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSizing.\u003c\/strong\u003e Size against 2100 W, not 3000 VA. Total the nameplate watts of your load and aim to stay below about 1680 W — 80% of capacity — so you keep headroom for inrush and for battery ageing. Schneider publishes no runtime table for this model, so ask us rather than work from a figure found elsewhere.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput.\u003c\/strong\u003e IEC C20 inlet. At 3000 VA plan a dedicated circuit; sharing a general office ring at this rating invites nuisance tripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eForm factor.\u003c\/strong\u003e Tower, 435 × 197 × 544 mm and 43 kg — a floor-standing unit. The rack equivalent is the \u003ca href=\"\/products\/apc-smart-ups-c-line-interactive-3kva-rackmount-2u-230v-smc3000rmi2u\"\u003eSMC3000RMI2U\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManagement.\u003c\/strong\u003e This model has \u003cstrong\u003eno SmartSlot\u003c\/strong\u003e. An internal APC network management card such as the AP9640 or AP9641 cannot be fitted to any Smart-UPS C unit — management is over the bundled USB or serial port to a host running APC PowerChute software. If you need SNMP or web management in the rack, choose a Smart-UPS SMT or SMX model with a SmartSlot, or a Smart-UPS C SmartConnect model with a built-in Ethernet port.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Smart-UPS C Series Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAPC Smart-UPS C 3000VA UPS (SMC3000I)\u003c\/li\u003e\n\u003cli\u003eSoftware CD\u003c\/li\u003e\n\u003cli\u003eDocumentation CD\u003c\/li\u003e\n\u003cli\u003eUSB cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSmart-UPS C Series Ordering Information\u003c\/h3\u003e\n\u003cp\u003eThe Smart-UPS C range runs from 1000 VA to 3000 VA in both tower and 2U rack builds. Watts, not VA, is the number to size against:\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-c-1000va-lcd-230v-smc1000i\"\u003eAPC Smart-UPS C 1000VA LCD 230V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMC1000I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-c-1500va-lcd-230v-smc1500i\"\u003eAPC Smart-UPS C 1500VA LCD 230V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMC1500I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-c-2000va-lcd-230v-smc2000i\"\u003eAPC Smart-UPS C 2000VA LCD 230V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMC2000I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPC Smart-UPS C 3000VA LCD 230V (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSMC3000I\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eSmart-UPS C rackmount siblings\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-c-1000va-2u-rack-mountable-lcd-230v-smc1000i-2u\"\u003eAPC Smart-UPS C 1000VA 2U Rack LCD 230V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMC1000I-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/smart-ups-c-1500va-2u-rack-mountable-lcd-230v-smc1500i-2u\"\u003eAPC Smart-UPS C 1500VA 2U Rack LCD 230V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMC1500I-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/smart-ups-c-2000va-2u-rack-mountable-230v-smc2000i-2u\"\u003eAPC Smart-UPS C 2000VA 2U Rack 230V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMC2000I-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-c-line-interactive-3kva-rackmount-2u-230v-smc3000rmi2u\"\u003eAPC Smart-UPS C 3kVA Rackmount 2U 230V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMC3000RMI2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eSmart-UPS C SmartConnect builds (with built-in Ethernet monitoring)\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-c-1000va-lcd-230v-with-smartconnect-smc1000ic\"\u003eAPC Smart-UPS C 1000VA LCD 230V with SmartConnect\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMC1000IC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-c-1500va-lcd-230v-with-smartconnect-smc1500ic\"\u003eAPC Smart-UPS C 1500VA LCD 230V with SmartConnect\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMC1500IC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-c-1000va-lcd-rm-2u-230v-with-smartconnect-smc1000i-2uc\"\u003eAPC Smart-UPS C 1000VA LCD RM 2U 230V with SmartConnect\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMC1000I-2UC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-c-1500va-lcd-rm-2u-230v-with-smartconnect-smc1500i-2uc\"\u003eAPC Smart-UPS C 1500VA LCD RM 2U 230V with SmartConnect\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMC1500I-2UC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eReplacement battery cartridge for this model\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-150-apcrbc150\"\u003eAPC Replacement Battery Cartridge #150\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPCRBC150\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eFull technical documentation for the APC SMC3000I is published by Schneider Electric. The official product page below lists the Schneider Electric product data sheet and User Guide 990-4493G.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/id\/en\/product\/SMC3000I\/apc-smartups-c-line-interactive-3kva-tower-230v-8x-iec-c13+1x-iec-c19-outlets-usb-and-serial-communication-avr-graphic-lcd\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric official product page — APC SMC3000I\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eSchneider Electric serves its datasheet and manual PDFs through a redirecting download service that we cannot link to reliably, so we do not publish a direct PDF link that might break or return the wrong model's document. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with the model number and we will send you the current APC SMC3000I product data sheet and user manual as PDFs, along with a quotation.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SMC3000I\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhat is the difference between 3000 VA and 2100 W, and which matters?\u003c\/h3\u003e\n\u003cp\u003eWatts is the one that limits you. VA is apparent power, W is real power, and modern IT loads will reach the 2100 W ceiling well before the 3000 VA figure means anything. Total your nameplate watts and stay under roughly 1680 W to leave 20% headroom for inrush and battery ageing.\u003c\/p\u003e\n\u003ch3\u003eHow long will it run for?\u003c\/h3\u003e\n\u003cp\u003eSchneider Electric publishes no runtime table for the SMC3000I, so we will not quote one. Runtime is highly non-linear in load — halving the load far more than doubles the minutes. Send us your load in watts and the runtime you need and we will size it.\u003c\/p\u003e\n\u003ch3\u003eIs the output a true sine wave, and is it safe for active-PFC power supplies?\u003c\/h3\u003e\n\u003cp\u003eYes. True sine wave output with less than 5% distortion at full load, which is what active-PFC server supplies require. Step-approximated output found on Back-UPS and Easy UPS models can cause those supplies to drop the load or run hot — that is the practical reason to buy Smart-UPS rather than Back-UPS for server equipment.\u003c\/p\u003e\n\u003ch3\u003eWhich replacement battery cartridge does it take?\u003c\/h3\u003e\n\u003cp\u003eThe genuine APC \u003ca href=\"\/products\/apc-replacement-battery-cartridge-150-apcrbc150\"\u003eAPCRBC150\u003c\/a\u003e. It is user-replaceable, with 3 to 5 years of expected service life — shorter in a warm room, and Singapore ambient conditions are unforgiving on sealed lead-acid. Plan the swap into a maintenance window and follow the APC user guide.\u003c\/p\u003e\n\u003ch3\u003eCan I add a network management card or an external battery pack?\u003c\/h3\u003e\n\u003cp\u003eNeither. This model has \u003cstrong\u003eno SmartSlot\u003c\/strong\u003e. An internal APC network management card such as the AP9640 or AP9641 cannot be fitted to any Smart-UPS C unit — management is over the bundled USB or serial port to a host running APC PowerChute software. If you need SNMP or web management in the rack, choose a Smart-UPS SMT or SMX model with a SmartSlot, or a Smart-UPS C SmartConnect model with a built-in Ethernet port. And the Smart-UPS C series takes no external battery pack, so runtime is fixed by the internal battery.\u003c\/p\u003e\n\u003ch3\u003eShould I buy this or the rackmount SMC3000RMI2U?\u003c\/h3\u003e\n\u003cp\u003eSame electronics, same 3000 VA \/ 2100 W, same outlet count. The choice is physical: this tower is 435 × 197 × 544 mm and stands on the floor, while the \u003ca href=\"\/products\/apc-smart-ups-c-line-interactive-3kva-rackmount-2u-230v-smc3000rmi2u\"\u003eSMC3000RMI2U\u003c\/a\u003e is 2U of rack space but 670 mm deep and ships with mounting brackets rather than rails. Check your cabinet depth before choosing the rack build.\u003c\/p\u003e\n\u003ch3\u003eHow does it compare with the 2000 VA SMC2000I?\u003c\/h3\u003e\n\u003cp\u003eThe \u003ca href=\"\/products\/apc-smart-ups-c-2000va-lcd-230v-smc2000i\"\u003eSMC2000I\u003c\/a\u003e gives 1300 W and six C13 outlets in a much smaller 27.5 kg tower. This unit adds 800 W of headroom and two more C13 outlets. If your measured load is above about 1000 W, or you expect it to grow, take the 3000 VA.\u003c\/p\u003e\n\u003ch3\u003eIs the warranty valid in Singapore, and do I get a GST invoice?\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC SMC3000I sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SMC3000I with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bnygg_h0bdg\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43073614512292,"sku":"SMC3000I","price":1835.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_9dc54621-0419-49cc-a8c6-2d5ca5e241da.jpg?v=1789720433"},{"product_id":"apc-netshelter-6u-low-profile-wallmount-rack-enclosure-ar106vi","title":"APC NetShelter 6U Low-Profile Wallmount Rack Enclosure","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter WX 6U Low-Profile Wallmount Rack Enclosure, Server Depth, 230V Fans (AR106VI) - 5 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e6U of Server-Depth Rack Space That Hangs on a Wall\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter WX 6U Low-Profile Wallmount Enclosure (AR106VI) puts six usable rack units of EIA-310 19-inch mounting on a wall, with 762 mm of mounting depth - enough for a genuine short-depth server, not just patch panels and a switch. It holds up to 113 kg of static load, and can also stand on the floor with optional casters.\u003c\/p\u003e\n\u003cp\u003eThe point of the low-profile design is the room it does not take: the enclosure extends less than 330 mm off the wall, so it fits a corridor, a store room or the back of an office without eating floor space. External dimensions are 648 mm high, 353 mm wide and 968 mm deep.\u003c\/p\u003e\n\u003ch3\u003eThe 230V Variant - the Right One for Singapore\u003c\/h3\u003e\n\u003cp\u003eAR106VI is the 230 V build of this enclosure, with two integrated 230 V fans providing 103.83 l\/s of forced ventilation. AR106V is the 120 V build of the same enclosure. On Singapore's 230 V mains the AR106VI is the correct part number; the 120 V AR106V is not.\u003c\/p\u003e\n\u003cp\u003eThat active ventilation matters here. A sealed steel box in an unconditioned Singapore corridor becomes an oven; a cabinet with forced ventilation and a MERV 5 \/ G3 dust filter keeps air moving through the equipment instead of letting it stagnate. Fans move ambient air; they cannot cool below room temperature, so consider the room as well as the cabinet.\u003c\/p\u003e\n\u003ch3\u003eLockable Steel Doors, Removable Side Panels, Proper Cable Entry\u003c\/h3\u003e\n\u003cp\u003eFront and rear doors are lockable steel with single-point locking and are reversible, so the cabinet can open the way the room allows. Side panels are included. Two cable entry knockouts, 70 mm and 28 mm, come with brush strip panels, so cabling enters tidily and the ventilation path is not defeated by an open hole.\u003c\/p\u003e\n\u003cp\u003eThe enclosure ships fully assembled with 24 M6 cage nuts and mounting screws, so installation is a mounting job rather than a build.\u003c\/p\u003e\n\u003ch3\u003eWhere It Fits in a Singapore SME or Branch Office\u003c\/h3\u003e\n\u003cp\u003eThis is the enclosure for a comms cabinet in a shophouse office, a retail back room, a clinic, a school block or a branch site: somewhere with no server room, no raised floor and no spare corner, but a real need to lock away a firewall, a switch, a NAS and a small UPS.\u003c\/p\u003e\n\u003cp\u003ePair it with a 1U rack PDU and a rack-mount UPS and the whole site's IT sits behind one lockable door. Supplied and invoiced locally in Singapore with GST, and APC backs this enclosure with a 5-year manufacturer warranty.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AR106VI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAR106VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter 6U Low-Profile Wallmount Rack Enclosure Cabinet 230V Server Depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eNetShelter WX Low-profile Cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsable Height\u003c\/td\u003e\n\u003ctd\u003e6U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRail Standard\u003c\/td\u003e\n\u003ctd\u003eEIA-310 \/ EIA-310-E, 19-inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eCommercialised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e0731304402015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eYes - supplied and supported locally by SourceIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFunction \u0026amp; Fit\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWallmount, or standalone on optional casters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Orientation\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Static Load\u003c\/td\u003e\n\u003ctd\u003e113 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Depth\u003c\/td\u003e\n\u003ctd\u003e762 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall Projection\u003c\/td\u003e\n\u003ctd\u003eLess than 330 mm from the wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoors\u003c\/td\u003e\n\u003ctd\u003eLockable steel front and rear doors, single-point locking, reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide Panels\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVentilation\u003c\/td\u003e\n\u003ctd\u003e2 x integrated 230 V fans, airflow 103.83 l\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Filtration\u003c\/td\u003e\n\u003ctd\u003eMERV 5 \/ G3 dust filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Access\u003c\/td\u003e\n\u003ctd\u003e2 x knockouts, 70 mm and 28 mm, with brush strip panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e648 x 353 x 968 mm as published by Schneider Electric; the enclosure is also stated to project less than 330 mm from the wall - confirm the mounting footprint with SourceIT before installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e36.29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e44.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 2416\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eEnclosure shipped fully assembled, 24 x M6 cage nuts and mounting screws, dust filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat fits inside.\u003c\/strong\u003e Six usable rack units of EIA-310 19-inch mounting, 762 mm of mounting depth and a 113 kg static load rating. That is enough for a short-depth 1U or 2U server, a switch stack, a firewall, a patch panel and a 1U or 2U rack-mount UPS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCheck depth, not just U height.\u003c\/strong\u003e Measure the deepest item you plan to fit, add cabling allowance at the rear, and compare the total against the 762 mm mounting depth before ordering. Depth, not U count, is what usually decides whether a wallmount enclosure works.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich voltage variant to order.\u003c\/strong\u003e AR106VI is the 230 V build, with two integrated 230 V fans - the correct part for Singapore's 230 V, 50 Hz supply. AR106V is the 120 V North American build of the same enclosure. Ordering the wrong one leaves you with fans that will not run correctly on local mains.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWall and floor mounting.\u003c\/strong\u003e Designed to hang on a wall and project less than 330 mm from it. It can also be used standing, with optional casters. At 36.29 kg empty plus up to 113 kg of equipment, wall fixing must be into structure rated for the combined load - confirm the wall construction before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRack power to go with it.\u003c\/strong\u003e A 1U rack PDU is the natural companion for a 6U enclosure. In the SourceIT catalogue the \u003ca href=\"\/products\/apc-easy-rack-pdu-basic-1u-1-phase-2-3kw-230v-epdu1010b-sch\"\u003eEasy Rack PDU Basic 1U (EPDU1010B-SCH)\u003c\/a\u003e gives six SCHUKO and one C13 outlet from a C14 inlet at 10 A, and the \u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559 Rack PDU Basic 1U\u003c\/a\u003e gives ten C13 and two C19 outlets at 16 A. Remember each consumes 1U of your six.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring.\u003c\/strong\u003e An enclosure on a wall in an unconditioned space is exactly where temperature and humidity monitoring earns its keep - see the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH sensor\u003c\/a\u003e with an \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641\u003c\/a\u003e card in the rack UPS, or a \u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNetBotz Rack Monitor 250\u003c\/a\u003e if you also want door access control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot a power product.\u003c\/strong\u003e The AR106VI is a passive steel enclosure. The 230 V in its name refers to the supply for its two integrated fans - it has no power distribution, no metering and no input rating of its own. Power distribution comes from a rack PDU installed inside it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; APC NetShelter WX Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eIn the box:\u003c\/strong\u003e the enclosure shipped fully assembled, 24 x M6 cage nuts and mounting screws, and a MERV 5 \/ G3 dust filter. Side panels and both lockable doors are part of the enclosure as supplied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetShelter WX low-profile wallmount enclosure - voltage variants\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBuild\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAR106VI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6U, server depth, 230 V integrated fans - the Singapore build\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAR106V\u003c\/td\u003e\n\u003ctd\u003e6U, server depth, 120 V integrated fans - not suited to Singapore mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRack power for a 6U enclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-easy-rack-pdu-basic-1u-1-phase-2-3kw-230v-epdu1010b-sch\"\u003eEPDU1010B-SCH\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy Rack PDU Basic, 1U, 10 A, 2.3 kW - 6 SCHUKO + 1 C13, C14 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU Basic, 1U, 16 A, 3.7 kW - 10 C13 + 2 C19, C20 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-12c13\"\u003eAP9565\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRack PDU Basic, 1U, 16 A, 3.7 kW - 12 C13, no C19, C20 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRack-mount UPS that suits a 6U wallmount enclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-1500va-lcd-rm-1u-230v-smt1500rmi1u\"\u003eSMT1500RMI1U\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 1500VA LCD RM 1U 230V - 1U of your 6U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-1500va-lcd-rm-2u-230v-with-smartconnect-smt1500rmi2uc\"\u003eSMT1500RMI2UC\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 1500VA LCD RM 2U 230V with SmartConnect - 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring for the enclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature and humidity sensor, RJ45, 3.9 m lead - needs a host: an \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641\u003c\/a\u003e card in the rack UPS, or a NetBotz appliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNBRK0250A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNetBotz Rack Monitor 250 - environmental sensing plus badged access control for 2 rack doors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AR106VI. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/AR106VI\/apc-netshelter-6u-lowprofile-wallmount-rack-enclosure-cabinet-230v-server-depth\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page (Singapore) - APC NetShelter 6U Low-Profile Wallmount Enclosure AR106VI\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/se.com\/be\/en\/download\/document\/990-6229_EN\" target=\"_blank\" rel=\"noopener\"\u003eNetShelter WX Low-profile Cabinet installation and customization manual (990-6229_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed a specific document, a compliance declaration or a written quotation? Contact SourceIT and we will supply it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AR106VI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat does the \"VI\" in AR106VI mean, and how does it differ from AR106V?\u003c\/h4\u003e\n\u003cp\u003eIt is the voltage build. AR106VI is the 230 V version, with two integrated 230 V fans - the correct part for Singapore. AR106V is the same enclosure with 120 V fans for the North American market. Schneider's own product names carry the distinction: \"230V Server Depth\" versus \"120V Server Depth\". If a supplier offers you an AR106V for a Singapore site, the fans are the problem.\u003c\/p\u003e\n\u003ch4\u003eDoes the enclosure have a power rating or built-in power distribution?\u003c\/h4\u003e\n\u003cp\u003eNo. It is a passive steel enclosure. The 230 V in the product name refers only to the supply for its two integrated ventilation fans. Power distribution to your equipment comes from a rack PDU fitted inside - for a 6U cabinet the \u003ca href=\"\/products\/apc-easy-rack-pdu-basic-1u-1-phase-2-3kw-230v-epdu1010b-sch\"\u003eEPDU1010B-SCH\u003c\/a\u003e or \u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559\u003c\/a\u003e 1U units are the usual choices.\u003c\/p\u003e\n\u003ch4\u003eHow much equipment will it hold?\u003c\/h4\u003e\n\u003cp\u003eSix usable rack units on EIA-310 19-inch rails, up to a 113 kg static load, with 762 mm of mounting depth. Depth is the figure that most often decides it: 762 mm of mounting depth takes a genuine short-depth server. Measure your deepest item plus rear cabling allowance against that figure before ordering.\u003c\/p\u003e\n\u003ch4\u003eHow far does it stick out from the wall?\u003c\/h4\u003e\n\u003cp\u003eLess than 330 mm. That is the whole point of the low-profile design: it fits a corridor, store room or office wall without obstructing it, while still offering 762 mm of mounting depth for real equipment. Schneider also publishes external dimensions of 648 x 353 x 968 mm (H x W x D) - ask SourceIT to confirm the mounting footprint for your wall before installation.\u003c\/p\u003e\n\u003ch4\u003eIs it lockable, and can the doors be reversed?\u003c\/h4\u003e\n\u003cp\u003eYes to both. Front and rear doors are lockable steel with single-point locking and are reversible, so the cabinet can be hung to suit the space. Side panels are included, and two cable entry knockouts of 70 mm and 28 mm come with brush strip panels to keep the ventilation path intact.\u003c\/p\u003e\n\u003ch4\u003eDoes it need cooling, and is any fitted?\u003c\/h4\u003e\n\u003cp\u003eTwo 230 V fans are integrated, giving 103.83 l\/s of airflow, with a MERV 5 \/ G3 dust filter. In an unconditioned Singapore corridor that forced ventilation matters, because a sealed cabinet lets heat build around the equipment - though fans move ambient air and cannot cool below room temperature, so consider the room as well as the cabinet. To know what the cabinet is actually running at, add an \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH sensor\u003c\/a\u003e on an \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641\u003c\/a\u003e card in the rack UPS - the sensor is a probe and needs that host to report.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC AR106VI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the AR106VI with a 5-year manufacturer warranty, which is longer than the term carried by most of the APC electronics in this catalogue.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43074993651876,"sku":"AR106VI","price":1525.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-netshelter-6u-low-profile-wallmount-rack-enclosure-ar106vi-432478.jpg?v=1672995000"},{"product_id":"apc-smart-ups-x-series-external-battery-pack-rack-tower-48v-smx48rmbp2u","title":"APC Smart-UPS X External Battery Pack 48V","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Smart-UPS X-Series External Battery Pack, Rack\/Tower 2U, 48 V, 864 VAh (SMX48RMBP2U) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eExtended Runtime for Smart-UPS X 750 VA to 1500 VA in Singapore Server Rooms\u003c\/h3\u003e\n\u003cp\u003eThe APC SMX48RMBP2U is the 48 V DC external battery pack built for the Smart-UPS X range at 750 VA, 1000 VA and 1500 VA. It stores 864 VAh and connects directly to the UPS battery bus, so the UPS itself does the charging, the monitoring and the runtime calculation. For a Singapore comms cabinet or small server room, this is how you turn a few minutes of ride-through into enough time for a controlled shutdown of a hypervisor host, a NAS or a core switch stack when a PUB feeder dips during an afternoon storm.\u003c\/p\u003e\n\u003ch3\u003e2U Rack or Tower, 490 mm Deep, 28.64 kg\u003c\/h3\u003e\n\u003cp\u003eThe pack is a genuine rack\/tower convertible chassis: 89 mm high (2U), 432 mm wide and 490 mm deep, weighing 28.64 kg net. Plan the rack accordingly — a lead-acid battery pack of this size belongs at the bottom of the cabinet, and the 490 mm depth matches the SMX750I, SMX1000I and SMX1500RMI2U UPS chassis it sits beneath. Rails, rack-mount brackets, two stabiliser brackets and their spacers are supplied in the carton.\u003c\/p\u003e\n\u003ch3\u003eStack Up to Five Packs on One UPS\u003c\/h3\u003e\n\u003cp\u003eA single Smart-UPS X unit will recognise and manage as many as five SMX48RMBP2U packs. Runtime scales close to linearly with each pack added, and because the UPS reads the pack count itself, the front-panel runtime estimate and any PowerChute shutdown timing stay accurate as you expand. That makes it a practical way to grow ride-through without replacing the UPS.\u003c\/p\u003e\n\u003ch3\u003eGenuine APC Cells, Local Supply, GST Invoice\u003c\/h3\u003e\n\u003cp\u003eInside the pack are two APCRBC115 replacement battery cartridges — the same genuine APC cartridges used in the Smart-UPS X 1500 VA UPS itself, which keeps your spares list short. Singapore's year-round humidity and 25–30 °C ambient are hard on sealed lead-acid chemistry, so buying through a local supplier with fresh stock matters. SourceIT supplies the SMX48RMBP2U with a GST invoice and local Singapore warranty support.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC SMX48RMBP2U Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eSMX48RMBP2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS X-Series External Battery Pack, Rack\/Tower 2U, 48 V, 864 VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExternal battery pack (XLBP) for APC Smart-UPS X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eRack\/Tower convertible, 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBattery Specifications\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Battery Voltage\u003c\/td\u003e\n\u003ctd\u003e48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStored Energy\u003c\/td\u003e\n\u003ctd\u003e864 VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLead-acid (Schneider Electric data sheet wording)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC115 × 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Packs per UPS\u003c\/td\u003e\n\u003ctd\u003eUp to five\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e89 × 432 × 490 mm (3.50 × 17.01 × 19.29 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e28.64 kg (63.14 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e35.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e62 × 58.9 × 24.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Compliance\u003c\/td\u003e\n\u003ctd\u003eMercury free; REACh free of SVHC; EU RoHS pro-active compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eExternal battery pack, one pair of rails, one pair of rack-mount brackets, two stabiliser brackets, two spacers for the stabiliser brackets, installation guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eSpecifications We Have Not Published\u003c\/h3\u003e\n\u003cp\u003eSchneider Electric does not publish an operating temperature, humidity, recharge time or safety-agency certification list on the SMX48RMBP2U data sheet, and does not describe the pack as hot-swappable. Those figures are therefore not stated here rather than estimated. Barcode data on this SKU is currently inconsistent between sources — ask us to confirm against physical stock if you need it for goods-receipt. Where Schneider Electric does not publish a figure for this exact model, SourceIT leaves it out rather than estimate it from a similar part number.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eThe SMX48RMBP2U is the 48 V pack. It serves the lower half of the Smart-UPS X range — the 750 VA, 1000 VA and 1500 VA models. It is \u003cstrong\u003enot\u003c\/strong\u003e interchangeable with the 120 V packs (SMX120BP and SMX120RMBP2U), which serve the 2200 VA and 3000 VA models on a completely different battery bus voltage.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-750va-rack-tower-lcd-230v-smx750i\"\u003eAPC Smart-UPS X 750VA Rack\/Tower LCD 230V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMX750I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-1000va-rack-tower-lcd-230v-smx1000i\"\u003eAPC Smart-UPS X 1000VA Rack\/Tower LCD 230V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMX1000I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-1500va-rack-tower-lcd-230v-smx1500rmi2u\"\u003eAPC Smart-UPS X 1500VA Rack\/Tower LCD 230V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMX1500RMI2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-1500va-r-tower-lcd-230v-smx1500rmi2unc\"\u003eAPC Smart-UPS X 1500VA R\/Tower LCD 230V with Network Card\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMX1500RMI2UNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eRuntime depends entirely on the connected load, so no single figure applies. As a rule, each additional pack adds roughly the same increment of runtime as the one before it, and a lightly loaded UPS gains disproportionately more minutes than a heavily loaded one. Tell us your actual load in watts and how many minutes you need, and we will size the number of packs for you rather than guess.\u003c\/p\u003e\n\u003cp\u003eThe pack carries no outlets and no AC input of its own — it is a DC battery extension that connects to the UPS. All load connection, metering and management stay with the UPS, including any SmartSlot network management card fitted to it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Smart-UPS X Battery Pack Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAPC Smart-UPS X-Series External Battery Pack (SMX48RMBP2U)\u003c\/li\u003e\n\u003cli\u003eOne pair of rack rails\u003c\/li\u003e\n\u003cli\u003eOne pair of rack-mount brackets\u003c\/li\u003e\n\u003cli\u003eTwo stabiliser brackets and two spacers (tower orientation)\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSmart-UPS X Battery Pack Ordering Information\u003c\/h3\u003e\n\u003cp\u003eThe Smart-UPS X external battery packs split by battery bus voltage and by chassis. Choose the pack that matches your UPS, not the one that matches your rack:\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPC Smart-UPS X-Series External Battery Pack, Rack\/Tower 2U, 48 V (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSMX48RMBP2U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-battery-pack-for-extended-runtime-smx120rmbp2u\"\u003eAPC Smart-UPS X External Battery Pack, Rack\/Tower 2U, 120 V DC, with rail kit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMX120RMBP2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-120v-short-depth-ebb\"\u003eAPC Smart-UPS X-Series External Battery Pack, Rack\/Tower 4U, 120 V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSMX120BP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eReplacement battery cartridge inside this pack\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-115-apcrbc115\"\u003eAPC Replacement Battery Cartridge #115\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPCRBC115\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCartridges for the matching UPS\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-116-apcrbc116\"\u003eAPC Replacement Battery Cartridge #116 (SMX750I \/ SMX1000I)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPCRBC116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-115-apcrbc115\"\u003eAPC Replacement Battery Cartridge #115 (SMX1500RMI2U)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPCRBC115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eFull technical documentation for the APC SMX48RMBP2U is published by Schneider Electric. The official product page below lists the Schneider Electric product data sheet and the SMX48RMBP2U Installation Sheet.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/product\/SMX48RMBP2U\/apc-smartups-xseries-external-battery-pack-rack-tower-48v-864vah-rackmount-2u\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric official product page — APC SMX48RMBP2U\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eSchneider Electric serves its datasheet and manual PDFs through a redirecting download service that we cannot link to reliably, so we do not publish a direct PDF link that might break or return the wrong model's document. Email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with the model number and we will send you the current APC SMX48RMBP2U product data sheet and user manual as PDFs, along with a quotation.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC SMX48RMBP2U\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003eWhich UPS models does the SMX48RMBP2U fit?\u003c\/h3\u003e\n\u003cp\u003eIt is the 48 V pack for the Smart-UPS X 750 VA, 1000 VA and 1500 VA models — in the SourceIT range that is the \u003ca href=\"\/products\/apc-smart-ups-x-750va-rack-tower-lcd-230v-smx750i\"\u003eSMX750I\u003c\/a\u003e, \u003ca href=\"\/products\/apc-smart-ups-x-1000va-rack-tower-lcd-230v-smx1000i\"\u003eSMX1000I\u003c\/a\u003e, \u003ca href=\"\/products\/apc-smart-ups-x-1500va-rack-tower-lcd-230v-smx1500rmi2u\"\u003eSMX1500RMI2U\u003c\/a\u003e and \u003ca href=\"\/products\/apc-smart-ups-x-1500va-r-tower-lcd-230v-smx1500rmi2unc\"\u003eSMX1500RMI2UNC\u003c\/a\u003e. It will not work with the 2200 VA or 3000 VA Smart-UPS X models, which run a 120 V battery bus.\u003c\/p\u003e\n\u003ch3\u003eHow many packs can I connect to one UPS?\u003c\/h3\u003e\n\u003cp\u003eUp to five. The UPS display recognises each pack as it is added and adjusts its runtime estimate accordingly, so you do not need to reconfigure anything after installation.\u003c\/p\u003e\n\u003ch3\u003eHow much extra runtime will I actually get?\u003c\/h3\u003e\n\u003cp\u003eThat depends on your load. A pack stores 864 VAh; how long that lasts is a function of the watts you are drawing, and Schneider does not publish a runtime table for this pack. Send us your load in watts and your target runtime in minutes and we will work out the pack count.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between SMX48RMBP2U, SMX120RMBP2U and SMX120BP?\u003c\/h3\u003e\n\u003cp\u003eBattery bus voltage first, then chassis. The SMX48RMBP2U is 48 V for the 750–1500 VA models. The \u003ca href=\"\/products\/apc-smart-ups-x-battery-pack-for-extended-runtime-smx120rmbp2u\"\u003eSMX120RMBP2U\u003c\/a\u003e is a 120 V 2U pack for the 2U rack Smart-UPS X models, and the \u003ca href=\"\/products\/apc-smart-ups-x-120v-short-depth-ebb\"\u003eSMX120BP\u003c\/a\u003e is a 120 V 4U pack for the 4U tower\/rack models. They are not substitutes for one another.\u003c\/p\u003e\n\u003ch3\u003eWhat batteries are inside, and can I replace them later?\u003c\/h3\u003e\n\u003cp\u003eTwo APCRBC115 genuine APC replacement battery cartridges. When the pack reaches end of battery life you replace the cartridges rather than the whole pack — order the \u003ca href=\"\/products\/apc-replacement-battery-cartridge-115-apcrbc115\"\u003eAPCRBC115\u003c\/a\u003e from us. Follow the safety instructions in the APC installation guide when servicing; Schneider does not describe this pack as hot-swappable, so plan the work into a maintenance window.\u003c\/p\u003e\n\u003ch3\u003eWhat do I need to allow for in the rack?\u003c\/h3\u003e\n\u003cp\u003e2U of height, 490 mm of depth and 28.64 kg of weight per pack. Mount battery packs low in the cabinet for stability, and check your rack's static load rating before stacking several.\u003c\/p\u003e\n\u003ch3\u003eIs the warranty valid in Singapore, and do I get a GST invoice?\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC SMX48RMBP2U sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the SMX48RMBP2U with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43075023110308,"sku":"SMX48RMBP2U","price":1195.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_2df9378f-2e9b-4f18-b8c2-1843ecaee7c8.png?v=1789720522"},{"product_id":"apc-replacement-battery-cartridge-apcrbc140","title":"APC Replacement Battery Cartridge #140","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Replacement Battery Cartridge #140 for Smart-UPS On-Line, 192V 5.1Ah Battery (APCRBC140) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eGenuine APC Replacement Battery Cartridge #140\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC Replacement Battery Cartridge #140 (APCRBC140) is Schneider Electric's own 192 V DC replacement cartridge for the larger Smart-UPS On-Line systems. It is supplied as two battery modules totalling 34.55 kg and 597 mm deep, rated at 5.1 Ah, with the connectors already fitted. This is a data-centre-class part: it is the battery inside a UPS that is holding up a comms room or a server rack, and it is exactly the component whose age nobody tracks until the day the room goes dark.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy UPS Batteries Need Replacing in Singapore\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSealed lead-acid cells age faster in heat, and a comms cabinet or server room running warm will shorten a cartridge's working life well before its calendar age suggests. Schneider rates this cartridge for operation from 0 to 40 °C at up to 95% relative humidity, so a well-ventilated, air-conditioned rack is doing real work for your battery budget. The failure mode is the dangerous part: a UPS with a tired battery still shows a healthy front panel and still passes mains through, then drops the load the moment a PUB supply dip or a storm-season brownout actually arrives. If your unit has started reporting a battery fault, or has simply been in service for several years, replace the cartridge before you find out the hard way.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eThe Cartridge That Superseded the RBC44\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSchneider's own support documentation is clear on one useful point: the APCRBC140 replaced the older RBC44, and where the RBC44 worked only in SURT units, the APCRBC140 can be used in both SRT and SURT systems. That makes it the current part for a mixed installed base of older SURT and newer SRT machines — one cartridge number to hold rather than two. Schneider's safety documentation describes it as the 192 V battery cartridge for Smart-UPS On-Line systems from 5 kVA to 20 kVA, while a separate support FAQ describes it as covering all SURT and SRT models of 3 kVA and larger. Those two statements do not quite agree on the lower bound, so match the cartridge to your unit's 192 V battery bus and send us the model number to confirm.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLocal Singapore Stock, GST Invoice and Local Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSourceIT holds APC replacement cartridges in Singapore, so a failed battery does not mean a multi-week import wait on a unit that is currently protecting nothing. Every order ships with a GST invoice for your accounts team and carries local Singapore warranty support, and we can quote the cartridge alongside the matching UPS, rack PDU or network management card on a single purchase order. We can also look at arranging collection of the exhausted cartridge for proper lead-acid recycling when the replacement is delivered — ask for that when you order.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC Replacement Battery Cartridge #140 (APCRBC140) Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAPC Replacement Battery Cartridge (RBC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAPCRBC140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Replacement Battery Cartridge for Smart-UPS On-Line, 192V 5.1Ah lead-acid battery, 2-year repair or replace warranty. Earlier documentation uses \"APC Replacement battery cartridge #140 with 2 Year Warranty\".\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003e2 years repair or replace, stated worldwide with no regional variation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupported locally by SourceIT Pte Ltd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Code (as published by APC)\u003c\/td\u003e\n\u003ctd\u003e731304310068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBattery Specifications\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Chemistry\u003c\/td\u003e\n\u003ctd\u003eLead-acid battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e192 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e5.1 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Modules\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Service Life\u003c\/td\u003e\n\u003ctd\u003eNot published against this part number; Schneider's general guidance for sealed lead-acid cartridges is three to five years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C, 0 to 95% relative humidity non-condensing, 0 to 10,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Environment\u003c\/td\u003e\n\u003ctd\u003e-15 to 45 °C, 0 to 95% relative humidity non-condensing, 0 to 50,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e122 x 197 x 597 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e34.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003eSchneider's data sheet prints an obviously erroneous figure for this field, so no shipping weight is published here. Plan freight against the 34.55 kg net weight and ask us to confirm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimensions\u003c\/td\u003e\n\u003ctd\u003e226 x 409 x 781 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003ePro-active compliance (product out of EU RoHS legal scope); REACh declaration available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Footprint\u003c\/td\u003e\n\u003ctd\u003e238 kg CO2 eq. over the product lifecycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eEvery figure above is taken from Schneider Electric's own published documentation for this exact part number. Where Schneider does not publish a value, the row says so rather than carrying a figure borrowed from a similar cartridge — APC ratings differ between parts that look identical.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Schneider states.\u003c\/strong\u003e Its support FAQ for this part reads: \"All SURT\/SRT models 3Kva or larger\", and adds that \"this RBC kit replaced the older RBC44. APCRBC140 can be used in SRT or SURT unit, RBC44 only work in SURT\". Its safety documentation separately describes the APCRBC140 as the 192 V battery cartridge for Smart-UPS On-Line systems of 5 kVA to 20 kVA, naming SRT and SURT 5K to 10K units among others. The two statements differ on the lower bound, so treat 192 V — the battery bus voltage — as the deciding characteristic and confirm your model with us.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSourceIT Smart-UPS On-Line models on a 192 V battery bus.\u003c\/strong\u003e These are the units in our range that Schneider's safety documentation places in scope for this cartridge:\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-5000va-rm-230v-srt5krmxli\"\u003eSRT5KRMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS SRT 5000VA RM 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-6000va-230v-srt6kxli\"\u003eSRT6KXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS SRT 6000VA 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-6000va-rm-230v-srt6krmxli\"\u003eSRT6KRMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS SRT 6000VA RM 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-8000va-230v-srt8kxli\"\u003eSRT8KXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS SRT 8000VA 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-8000va-rm-230v-srt8krmxli\"\u003eSRT8KRMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS SRT 8000VA RM 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-10000va-rm-230v-srt10krmxli\"\u003eSRT10KRMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS SRT 10000VA RM 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe matching external battery packs for these systems — \u003ca href=\"\/products\/apc-smart-ups-srt-192v-5kva-and-6kva-battery-pack-srt192bp\"\u003eSRT192BP\u003c\/a\u003e, \u003ca href=\"\/products\/apc-smart-ups-srt-192v-5kva-and-6kva-rm-battery-pack-srt192rmbp\"\u003eSRT192RMBP\u003c\/a\u003e, \u003ca href=\"\/products\/apc-smart-ups-srt-192v-8kva-and-10kva-battery-pack-srt192bp2\"\u003eSRT192BP2\u003c\/a\u003e and \u003ca href=\"\/products\/apc-smart-ups-srt-192v-8-and-10kva-rm-battery-pack-srt192rmbp2\"\u003eSRT192RMBP2\u003c\/a\u003e — run on the same 192 V bus. Schneider does not publish a cartridge part number against those pack records, so ask us before ordering a cartridge for a pack rather than for the UPS itself.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical fit.\u003c\/strong\u003e Schneider rates this cartridge at 192 V DC, 5.1 Ah, supplied as two battery modules. The 34.55 kg net weight is consistent with a 192 V string, so the published voltage is the cartridge voltage and not a per-block figure. A UPS will only accept the cartridge built for it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRuntime after replacement.\u003c\/strong\u003e A new cartridge restores the runtime the UPS was rated for when new; it does not add runtime beyond that. How long that actually is depends entirely on how heavily the UPS is loaded — a unit at a quarter load runs for considerably longer than the same unit near its rated output. Schneider does not publish runtime figures against the cartridge itself, only against the UPS, so if you need a runtime target for a specific rack load, send us the load in watts and the UPS model and we will size it properly rather than quote a number that will not hold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation.\u003c\/strong\u003e The cartridge is supplied assembled with its connectors fitted. Schneider's own safety notice for this part describes the APCRBC140 as user serviceable and hot swappable; even so, follow the installation guide supplied in the box for the correct sequence on your model, and treat the modules as live throughout — this is a 192 V lead-acid assembly and a shorted terminal is a serious hazard. At 34.55 kg across the two modules, plan for a two-person lift. If you would rather not do it in-house, ask us and we will look at arranging it for you.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; RBC Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the Box\u003c\/h4\u003e\n\u003cp\u003eThe cartridge is supplied fully assembled with all required connectors pre-fitted. Schneider does not publish an itemised package contents list for this part number, so we do not invent one.\u003c\/p\u003e\n\u003ch4\u003eAPC Smart-UPS On-Line and Smart-UPS XL Replacement Cartridges Stocked by SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-105-apcrbc105\"\u003eAPCRBC105\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS XL 48 V external battery pack SUA48RMXLBP3U, which takes two\u003cbr\u003e48 V · 24.55 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPCRBC140 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS On-Line SRT and SURT units on a 192 V battery bus\u003cbr\u003e192 V, 5.1 Ah · 34.55 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMatching UPS Models\u003c\/h4\u003e\n\u003cp\u003eIf you are replacing or adding a Smart-UPS On-Line system rather than re-celling one, these are the SourceIT models on the 192 V battery bus this cartridge serves:\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-5000va-rm-230v-srt5krmxli\"\u003eSRT5KRMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS SRT 5000VA RM 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-6000va-230v-srt6kxli\"\u003eSRT6KXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS SRT 6000VA 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-6000va-rm-230v-srt6krmxli\"\u003eSRT6KRMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS SRT 6000VA RM 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-8000va-230v-srt8kxli\"\u003eSRT8KXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS SRT 8000VA 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-8000va-rm-230v-srt8krmxli\"\u003eSRT8KRMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS SRT 8000VA RM 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-10000va-rm-230v-srt10krmxli\"\u003eSRT10KRMXLI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS SRT 10000VA RM 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eAt 34.55 kg net across two modules this is a palletised or two-person delivery, not a parcel. Schneider also lists the part as non-stock in its own distribution, so ask us early if you have a planned maintenance window to hit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering notes.\u003c\/strong\u003e Quote the part number APCRBC140 on your purchase order — the cartridge number, not the UPS model, is what determines what ships. This cartridge is a lead-acid assembly and travels as such: net weights across the APC RBC range run from under 3 kg to over 30 kg, so check the physical specifications above before you arrange a courier. We can supply the cartridge on its own, or alongside a network management card, rack PDU or a replacement UPS on a single GST invoice.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.se.com\/us\/en\/product\/APCRBC140\/apc-replacement-battery-cartridge-for-smartups-online-192v-5-1ah-leadacid-battery-2year-repair-or-replace-warranty\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for APCRBC140\u003c\/a\u003e — official product identity, environmental data and document library (international catalogue)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/SPD_JGNY-9A5DFN_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eSmart-UPS On-Line Replacement Battery APCRBC140\/APCRBC140J — user guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/faqs\/FA333556\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider support FAQ — APCRBC140 compatibility and its supersession of the RBC44\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/work\/support\/safety-notices\/smart-ups-battery-and-apcrbc140\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider safety notice PRB-239058 — Smart-UPS battery and APCRBC140\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/th\/en\/download\/document\/SDS_AL_APCRBC_LEAD_ACID_NAM_EN\" target=\"_blank\" rel=\"noopener\"\u003eProduct Safety Data Sheet — APC rechargeable lead-acid RBC and battery packs\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider Electric serves its PDF datasheets from a download host that redirects and does not reliably return the document you asked for, so we do not publish direct PDF links here — a link that hands you another model's datasheet is worse than no link at all. If you need the signed product data sheet, the installation guide or a written confirmation of fitment for your unit, email us the UPS model number and we will send the current document across.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC Replacement Battery Cartridge #140 (APCRBC140)\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhich APC UPS models does the APCRBC140 fit?\u003c\/h4\u003e\n\u003cp\u003eSchneider's support FAQ states \"all SURT\/SRT models 3Kva or larger\", while its safety documentation describes the part as the 192 V cartridge for Smart-UPS On-Line systems of 5 kVA to 20 kVA and names SRT and SURT 5K to 10K units. The reliable test is the battery bus voltage: this cartridge is 192 V. Send us the model number from your unit and we will confirm it in writing before anything ships.\u003c\/p\u003e\n\u003ch4\u003eDoes the APCRBC140 replace the older RBC44?\u003c\/h4\u003e\n\u003cp\u003eYes. Schneider states that this cartridge kit replaced the RBC44, and that where the RBC44 worked only in SURT units, the APCRBC140 can be used in either SRT or SURT systems. If you are maintaining a mixed installed base of older SURT and newer SRT machines, that means one cartridge number to stock rather than two.\u003c\/p\u003e\n\u003ch4\u003eIs my APCRBC140 affected by the Schneider safety notice?\u003c\/h4\u003e\n\u003cp\u003eOnly a specific manufacturing window is. Schneider's product recall safety notice PRB-239058 covers cartridges manufactured between 6 May 2019 and 10 May 2020, identified by UPS serial date codes AS1919-AS2019, AQ1919-AQ2019 and 7S1919-7S2019, and battery module date codes 7A1919-7A2019 carrying labels BM13170, BR8376, BR8529, BM13756, BR8856 or MU1457. Schneider's stated hazard is that \"battery issues caused by an internal battery nonconformance may affect the battery performance and, in a very low number of cases, result in localized overheating\", and its stated remedy is that affected batteries need to be replaced and will be provided. The affected manufacturing window closed in May 2020, so this is an installed-base question rather than one about a cartridge bought new today — but if you are servicing an older system, read the date codes off the modules before you refit them. The notice is linked in the downloads section, and we are happy to check a date code for you.\u003c\/p\u003e\n\u003ch4\u003eHow do I make sure I am ordering the right cartridge?\u003c\/h4\u003e\n\u003cp\u003eRead the model number off the label on the rear or side of the UPS and select against that, never against the part number of the battery already inside it and never against the VA rating alone. Schneider says the same thing on its \u003ca href=\"https:\/\/www.se.com\/us\/en\/work\/products\/tools\/ups-replacement-battery-selector\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC UPS Replacement Battery Cartridge Selector Tool\u003c\/a\u003e: two units of identical capacity in tower and rack form take different cartridges, and a SmartConnect or network-card build often differs from the standard build of the same model. Send us the model number and we will confirm the correct cartridge in writing before you order.\u003c\/p\u003e\n\u003ch4\u003eCan I fit the cartridge myself?\u003c\/h4\u003e\n\u003cp\u003eSchneider's own safety notice describes the APCRBC140 as user serviceable and hot swappable, so on a supported system the modules can be changed without dropping the load. In practice, follow the installation guide supplied in the box for the correct sequence on your model rather than assuming, treat the modules as live throughout — this is a 192 V lead-acid assembly — and plan for a two-person lift at 34.55 kg across the two modules. If the UPS is protecting something you would rather not gamble on, ask us about arranging the replacement.\u003c\/p\u003e\n\u003ch4\u003eHow long should the cartridge last?\u003c\/h4\u003e\n\u003cp\u003eSchneider does not publish a service-life figure against this part number. Its general guidance for sealed lead-acid cartridges is three to five years, and on a Smart-UPS On-Line system the UPS itself will report battery health, so use that alongside age. In Singapore, the room temperature is the real variable: a comms room that runs warm will take years off a battery string that would otherwise reach the top of that range.\u003c\/p\u003e\n\u003ch4\u003eWhat do I do with the old cartridge?\u003c\/h4\u003e\n\u003cp\u003eDo not put it in general waste. A UPS cartridge is a sealed lead-acid assembly and is regulated waste in Singapore. Schneider supplies battery recycling information with the cartridge, and SourceIT can look at arranging collection of the exhausted pack for proper recycling when the replacement is delivered — tell us when you order so it can be scheduled with the delivery.\u003c\/p\u003e\n\u003ch4\u003eIs this a genuine APC part, and what does the warranty cover?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC Replacement Battery Cartridge #140 (APCRBC140) sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the APCRBC140 with a 2-year manufacturer warranty, stated as 2 years repair or replace. Schneider publishes this term worldwide with no regional variation, so the Singapore figure is the same 2 years quoted elsewhere — unlike some APC UPS families, where the European figure is higher and does not apply to a Singapore supply.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43075053715620,"sku":"APCRBC140","price":1045.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_df1310e4-29a7-4476-a9c3-dd560ae29cd4.jpg?v=1789720557"},{"product_id":"apc-replacement-battery-cartridge-152-apcrbc152","title":"APC Replacement battery cartridge #152","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003eAPC Replacement Battery Cartridge #152 (APCRBC152) - 2 Years Local Warranty\u003c\/h2\u003e\n\u003ch3\u003eAPCRBC152 Datasheet: the 96 V Cartridge for Smart-UPS On-Line SRT 3 kVA\u003c\/h3\u003e\n\u003cp\u003eThe APCRBC152 is the genuine APC replacement battery cartridge for the 96 V side of the Smart-UPS On-Line SRT range. Schneider's own installation guide covers it together with the APCRBC141 and pairs the two by system voltage: the APCRBC152 with the 96 V battery packs \u003ca href=\"\/products\/apc-smart-ups-srt-96v-3kva-battery-pack-srt96bp\"\u003eSRT96BP\u003c\/a\u003e and \u003ca href=\"\/products\/apc-smart-ups-srt-96v-3kva-rm-battery-pack-srt96rmbp\"\u003eSRT96RMBP\u003c\/a\u003e, the APCRBC141 with the 72 V \u003ca href=\"\/products\/apc-smart-ups-srt-72v-2-2kva-battery-pack-srt72bp\"\u003eSRT72BP\u003c\/a\u003e. That pack pairing is published, and it is the key to reading the rest of the part correctly.\u003c\/p\u003e\n\u003cp\u003eThis is a long, heavy tray — 762 mm deep and 15.29 kg — built as eight 12 V blocks in series. It is not a consumer part and it is not interchangeable with anything else in the range.\u003c\/p\u003e\n\u003ch3\u003eWhy This Listing Says 96 V and Schneider's Says 12 V\u003c\/h3\u003e\n\u003cp\u003eSchneider's current product name for this part reads \"12V 5Ah lead-acid battery\". That is the rating of one block inside the tray, not the rating of the cartridge, and it is the single most common source of confusion on this range.\u003c\/p\u003e\n\u003cp\u003eThe assembled cartridge is \u003cstrong\u003e96 V nominal\u003c\/strong\u003e, made up of eight 12 V blocks in series at 5 Ah. Three things establish it. Schneider's own installation guide pairs the cartridge with the 96 V SRT96BP and SRT96RMBP packs, and 96 divided by 12 is eight. The sibling APCRBC141, covered by the same guide, pairs with the 72 V packs and weighs 11.7 kg — six blocks at 1.95 kg each. This cartridge weighs 15.29 kg, which is eight blocks at 1.91 kg each, within two per cent of the same block. The mass, the block count and the pack voltage all agree.\u003c\/p\u003e\n\u003cp\u003eWe publish 96 V because the derivation is sound and because a buyer comparing this against a 12 V cartridge would otherwise be badly misled. If you want the underlying document, the installation guide is linked in the Downloads section below.\u003c\/p\u003e\n\u003ch3\u003eServer Rooms, Comms Cabinets and the Cost of a Tired Battery\u003c\/h3\u003e\n\u003cp\u003eDouble-conversion On-Line UPS units are bought for the loads that cannot tolerate a transfer — storage arrays, virtualisation hosts, medical and lab equipment, trading and payment systems. The irony is that the battery is the part most likely to fail, and it fails quietly. An SRT with an aged cartridge passes its daily checks and then delivers seconds instead of minutes during an actual PUB event.\u003c\/p\u003e\n\u003cp\u003eSingapore is hard on lead-acid batteries. Ambient temperature sits near the top of the useful band all year, and every few degrees of sustained heat shortens a sealed lead-acid battery's service life measurably. A comms cabinet or riser room that runs warm will age a cartridge faster than an air-conditioned server room will. Plan replacement on the calendar instead of waiting for the UPS to fail its self-test, and keep the unit out of direct sun and clear of the warm-air discharge from whatever it is protecting. On a 3 kVA On-Line unit carrying real load, a tired cartridge is the difference between a graceful shutdown and a hard stop across everything in the cabinet.\u003c\/p\u003e\n\u003ch3\u003eGenuine APC Supply, GST-Invoiced, from Singapore Stock\u003c\/h3\u003e\n\u003cp\u003eSourceIT supplies the APCRBC152 as genuine APC by Schneider Electric stock, sold in Singapore with a GST invoice and local warranty support. We hold this part on the shelf instead of ordering it in, so a failed UPS does not have to wait on a shipment. If you are not certain which cartridge your unit takes, send us the model number printed on the UPS rear panel and we will confirm it against Schneider's documentation before you buy.\u003c\/p\u003e\n\u003cp\u003eSchneider Electric does not publish a UL listing or a CE marking for this cartridge, and we do not claim either. What Schneider does publish is a REACh declaration and a RoHS position, and those are reproduced in the specification table exactly as written.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPCRBC152 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAPCRBC152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Schneider Name\u003c\/td\u003e\n\u003ctd\u003eAPC Replacement Battery Cartridge for Smart-UPS On-Line, 12V 5Ah lead-acid battery, 2-year repair or replace warranty (the older catalogue name is \"APC Replacement battery cartridge #152 with 2 Year Warranty\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for Smart-UPS On-Line SRT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCartridges per Replacement\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Warranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty Coverage\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eBattery Specifications\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage (cartridge)\u003c\/td\u003e\n\u003ctd\u003e96 V — derived from the mass and the host pack voltage; the derivation is set out in full further up the page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e5 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy\u003c\/td\u003e\n\u003ctd\u003eApproximately 480 Wh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Blocks\u003c\/td\u003e\n\u003ctd\u003e8 x 12 V in series (derived from mass and host pack voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer's Per-Block Rating\u003c\/td\u003e\n\u003ctd\u003e12 V, 5 Ah — this is one block, not the cartridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLead-Acid battery (Schneider's published wording)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Service Life\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider for this part\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003eNot a cartridge property — the SRT charges to 90% in the first three hours on utility power, per Schneider's installation guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e76 x 210 x 762 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e15.29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e18.46 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e190 x 350 x 640 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack-mountable\u003c\/td\u003e\n\u003ctd\u003eNo (the cartridge itself; its host SRT is rack or tower)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C, 0 to 95% non-condensing, 0 to 10,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-15 to 45 °C, 0 to 95% non-condensing, 0 to 50,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecycled Plastic Content\u003c\/td\u003e\n\u003ctd\u003e15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging\u003c\/td\u003e\n\u003ctd\u003eRecycled cardboard, minimum 70% recycled content\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003ePro-active compliance; the product is outside the legal scope of EU RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTwo fields deliberately left out.\u003c\/strong\u003e Schneider publishes two different GTIN values for this part across two of its own document revisions, and two different carbon footprint figures across its product page and its data sheet. We have omitted both rather than pick one. If you need the barcode for goods-receipt, ask us and we will confirm which code is on the carton you are being shipped.\u003c\/p\u003e\n\u003cp\u003eSchneider publishes no charge time for a replacement cartridge. Recharge time is a property of the UPS that charges it, not of the battery tray, so look it up on your UPS model, not here.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat the APCRBC152 fits\u003c\/h4\u003e\n\u003cp\u003eFrom Schneider's own installation guide, document reference SPD_JGNY-9K29GH_EN, \"Installation Guide Smart-UPS On-Line APCRBC152 \/ APCRBC141\". The guide writes the host families with a trailing wildcard for the regional suffix, where \u003cstrong\u003eI\u003c\/strong\u003e is the 230 V international build, \u003cstrong\u003eA\u003c\/strong\u003e is 120 \/ 208 V North America, \u003cstrong\u003eT\u003c\/strong\u003e is 208 V and \u003cstrong\u003eJ\u003c\/strong\u003e is Japan. Singapore takes the \u003cstrong\u003eI\u003c\/strong\u003e builds.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSRT3000XLx\u003c\/strong\u003e and \u003cstrong\u003eSRT3000RMXLx\u003c\/strong\u003e — Smart-UPS On-Line 3 kVA tower and rackmount. SourceIT stocks the 230 V builds: \u003ca href=\"\/products\/apc-smart-ups-srt-3000va-230v-srt3000xli\"\u003eSRT3000XLI\u003c\/a\u003e and \u003ca href=\"\/products\/apc-smart-ups-on-line-3kva-rackmount-2u-230v-8x-c13-2x-c19-iec-srt3000rmxli\"\u003eSRT3000RMXLI\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSRT2200XLx\u003c\/strong\u003e and \u003cstrong\u003eSRT2200RMXLx\u003c\/strong\u003e — Smart-UPS On-Line 2.2 kVA tower and rackmount. SourceIT stocks \u003ca href=\"\/products\/apc-smart-ups-srt-2200va-230v-srt2200xli\"\u003eSRT2200XLI\u003c\/a\u003e and \u003ca href=\"\/products\/apc-smart-ups-srt-2200va-rm-230v-srt2200rmxli\"\u003eSRT2200RMXLI\u003c\/a\u003e. See the note below on which cartridge the 2.2 kVA units take.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-96v-3kva-battery-pack-srt96bp\"\u003eSRT96BP\u003c\/a\u003e\u003c\/strong\u003e — Smart-UPS SRT 96 V 3 kVA external battery pack, tower. Named directly by the installation guide. Stocked here.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/apc-smart-ups-srt-96v-3kva-rm-battery-pack-srt96rmbp\"\u003eSRT96RMBP\u003c\/a\u003e\u003c\/strong\u003e — Smart-UPS SRT 96 V 3 kVA external battery pack, rackmount. Named directly by the installation guide. Stocked here.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhich SRT takes the 152 and which takes the 141\u003c\/h4\u003e\n\u003cp\u003eSchneider's guide covers both cartridges against all four UPS families without splitting them model by model, so this is worth spelling out. The guide does split the \u003cem\u003ebattery packs\u003c\/em\u003e: the APCRBC152 goes with the 96 V \u003ca href=\"\/products\/apc-smart-ups-srt-96v-3kva-battery-pack-srt96bp\"\u003eSRT96BP\u003c\/a\u003e and \u003ca href=\"\/products\/apc-smart-ups-srt-96v-3kva-rm-battery-pack-srt96rmbp\"\u003eSRT96RMBP\u003c\/a\u003e, and the APCRBC141 goes with the 72 V \u003ca href=\"\/products\/apc-smart-ups-srt-72v-2-2kva-battery-pack-srt72bp\"\u003eSRT72BP\u003c\/a\u003e. Since the pack voltage follows the UPS bus voltage, the reading that fits the published evidence is that the \u003cstrong\u003e96 V 3 kVA\u003c\/strong\u003e systems take this cartridge and the \u003cstrong\u003e72 V 2.2 kVA\u003c\/strong\u003e systems take the APCRBC141.\u003c\/p\u003e\n\u003cp\u003eThat is a reasoned reading of Schneider's own document, not a quotation from it, so we say so plainly. Before you order for a 2.2 kVA unit, send us the model number and we will confirm it with the distributor. Getting this one wrong means a tray that does not seat.\u003c\/p\u003e\n\u003ch4\u003eRuntime\u003c\/h4\u003e\n\u003cp\u003eA fresh cartridge restores the SRT to the runtime it was rated for at your load; it does not extend it. If you need longer, that is what the external battery packs are for, and the 96 V packs above are the ones that match a 3 kVA SRT. Runtime falls steeply as load rises, so tell us the actual kW rather than the UPS rating and we will read the correct figure off the APC runtime chart.\u003c\/p\u003e\n\u003cp\u003eThe cartridge arrives assembled with its connectors already fitted. Schneider ships an installation guide in the box and that guide, not this page, is the authority on how the swap is done on your particular SRT and whether it can be done with the unit running. Read it before you start, and keep the old cartridge intact for recycling.\u003c\/p\u003e\n\u003cp\u003eSealed lead-acid cartridges must not go into general waste in Singapore. Bring the exhausted cartridge back to us with the replacement and we can arrange collection through a licensed recycler, or dispose of it through your own NEA-licensed collector.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Smart-UPS On-Line SRT Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOne APCRBC152 battery cartridge, assembled with connectors fitted\u003c\/li\u003e\n\u003cli\u003eSchneider Electric installation guide (document SPD_JGNY-9K29GH_EN)\u003c\/li\u003e\n\u003cli\u003eProtective packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSmart-UPS On-Line SRT cartridges and packs at SourceIT\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAPCRBC152 (this listing)\u003c\/strong\u003e — 96 V, 5 Ah, 15.29 kg. For the 96 V 3 kVA SRT systems and the SRT96BP \/ SRT96RMBP packs.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/apc-replacement-battery-cartridge-apcrbc140\"\u003eAPCRBC140\u003c\/a\u003e — Smart-UPS On-Line replacement cartridge.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/apc-replacement-battery-cartridge-117-apcrbc117\"\u003eAPCRBC117\u003c\/a\u003e — Smart-UPS X series cartridge.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMatching SRT hardware in stock\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/apc-smart-ups-srt-3000va-230v-srt3000xli\"\u003eSRT3000XLI\u003c\/a\u003e — Smart-UPS On-Line SRT 3000VA 230V, tower\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/apc-smart-ups-on-line-3kva-rackmount-2u-230v-8x-c13-2x-c19-iec-srt3000rmxli\"\u003eSRT3000RMXLI\u003c\/a\u003e — Smart-UPS On-Line SRT 3kVA rackmount 2U 230V\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/apc-smart-ups-srt-2200va-230v-srt2200xli\"\u003eSRT2200XLI\u003c\/a\u003e — Smart-UPS On-Line SRT 2200VA 230V, tower\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/apc-smart-ups-srt-2200va-rm-230v-srt2200rmxli\"\u003eSRT2200RMXLI\u003c\/a\u003e — Smart-UPS On-Line SRT 2200VA RM 230V\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/apc-smart-ups-srt-96v-3kva-battery-pack-srt96bp\"\u003eSRT96BP\u003c\/a\u003e — SRT 96V 3kVA external battery pack, tower\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/apc-smart-ups-srt-96v-3kva-rm-battery-pack-srt96rmbp\"\u003eSRT96RMBP\u003c\/a\u003e — SRT 96V 3kVA external battery pack, rackmount\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/apc-smart-ups-srt-72v-2-2kva-battery-pack-srt72bp\"\u003eSRT72BP\u003c\/a\u003e — SRT 72V 2.2kVA external battery pack\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBuying a cartridge and a pack together, or refitting several SRTs at once? Send the list to \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e for a consolidated GST-invoiced quotation.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eEvery link below is a Schneider Electric page we have opened and confirmed resolves.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/APCRBC152\/apc-replacement-battery-cartridge-152-with-2-year-warranty\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric Singapore product page, APCRBC152\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/ie\/en\/download\/document\/SPD_JGNY-9K29GH_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Guide, Smart-UPS On-Line APCRBC152 \/ APCRBC141\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/SPD_JHSH-7ENFZG_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eReplacement Battery Cartridge (RBC) manual, many Back-UPS and Smart-UPS SKUs\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/UPS_to_RBC_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eUPS to RBC Cross Reference List (Schneider Electric)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/APCRBC_SYBT_SDS_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPCRBC and SYBT (Lead Acid Battery) Safety Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe deliberately do not publish direct PDF links for this part. Schneider's file-download host redirects across domains and has repeatedly returned a different model's document than the one requested, so a direct link is not safe to rely on. Every link above is a Schneider Electric landing page that we have opened and checked. If you would like the PDF itself, email \u003ca href=\"mailto:sales@sourceit.com.sg\"\u003esales@sourceit.com.sg\u003c\/a\u003e with your UPS model and we will send the current revision together with a GST-invoiced quotation.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APCRBC152\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eIs the APCRBC152 a 12 V cartridge?\u003c\/strong\u003e\u003cbr\u003eNo. The assembled cartridge is 96 V nominal, built from eight 12 V blocks in series at 5 Ah. Schneider's product name says \"12V 5Ah\" because that is the rating of one block inside the tray. The 15.29 kg weight, the eight-block count and the 96 V SRT96BP pack Schneider pairs it with all agree on 96 V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich UPS models does it fit?\u003c\/strong\u003e\u003cbr\u003eSchneider's installation guide names the Smart-UPS On-Line SRT2200XL, SRT2200RMXL, SRT3000XL and SRT3000RMXL families, plus the SRT96BP and SRT96RMBP battery packs. For Singapore that means the 230 V \"I\" builds, all of which we stock. The guide pairs this cartridge specifically with the 96 V packs, which points to the 3 kVA systems; the 72 V 2.2 kVA systems point to the APCRBC141. Send us your model number and we will confirm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"XLI\" or \"RMXLI\" suffix on my SRT mean?\u003c\/strong\u003e\u003cbr\u003eXL is the extended-runtime build, RM is rackmount and I is the 230 V international version. So SRT3000XLI is a 3 kVA extended-runtime tower for 230 V mains and SRT3000RMXLI is the same electronics in a rack chassis. The A, T and J suffixes are the North American, 208 V and Japanese builds and are not sold here. The suffix genuinely changes the build, so quote it in full when you ask us to check a part.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this in a 2.2 kVA SRT?\u003c\/strong\u003e\u003cbr\u003eProbably not, and we would rather you asked than found out on site. The 2.2 kVA SRT systems run a 72 V bus and pair with the SRT72BP pack, which Schneider's guide matches to the APCRBC141 rather than to this cartridge. The guide does list both cartridges against both UPS families without splitting them, which is why we will not state it as certain. Send us the model number and we will confirm with the distributor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long does the cartridge last, and how long does it take to charge?\u003c\/strong\u003e\u003cbr\u003eSchneider publishes no expected service life for this part, so we do not quote one. In Singapore's climate, plan on the shorter end of whatever your maintenance regime assumes and test rather than guess. On charging, the SRT reaches about 90 per cent capacity in the first three hours on utility power according to Schneider's own guide, but a full recharge is a property of the UPS, not of the battery tray.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I change it without shutting the UPS down?\u003c\/strong\u003e\u003cbr\u003eThe cartridge ships assembled with connectors fitted, and Schneider's installation guide in the box is the authority on the procedure for your SRT. We do not publish a hot-swap claim for this cartridge because Schneider does not publish one for it. Read the guide first, and if the SRT carries a production load, plan a window.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the listing not show a barcode or a carbon figure?\u003c\/strong\u003e\u003cbr\u003eBecause Schneider publishes two conflicting values for each across its own documents, and we would rather show nothing than show the wrong one. Ask us for the code on the carton you are being shipped if you need it for goods-receipt.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it come with a local Singapore warranty?\u003c\/strong\u003e\u003cbr\u003eYes. Every APCRBC152 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the APCRBC152 with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43075078586532,"sku":"APCRBC152","price":1045.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_1f94906f-ad82-43a1-aea2-a220f7483bfa.png?v=1789720580"},{"product_id":"apc-netshelter-metered-rack-pdu-ap8853","title":"APC NetShelter Metered Rack PDU","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Metered Rack PDU, 0U, 1 Phase, 7.4kW 230V 32A, (36) C13 \u0026amp; (6) C19, IEC 309 Cord (AP8853) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eForty-Two Outlets and 7.4 kW, Consuming Zero Rack Units\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Metered Rack PDU AP8853 is the largest unit in this rack power range: thirty-six IEC C13 outlets and six IEC C19 outlets on a 1,791 mm vertical strip, carrying 7,400 VA at 230 V and 32 A. Mounted in the rear vertical channel, all of that capacity costs you no usable rack units at all.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDevice, Phase and Breaker-Bank Metering with an Interactive LCD\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AP8853 measures current, power and voltage and presents them on an interactive LCD at the strip itself, as well as over the network. Metering is at device, phase and breaker-bank level - accurate to ±3% - which is what you need to balance the two banks properly and to see capacity headroom before you commit the next server to the rack. The display module is field-replaceable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Monitoring in the Rack\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA sensor port takes the APC AP9335T temperature probe or the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH temperature and humidity sensor\u003c\/a\u003e, so the PDU can report rack inlet conditions alongside power. In Singapore's climate, where a failed CRAC unit turns into a thermal problem within minutes and ambient humidity works steadily against equipment life, that is a genuinely useful thing to have reporting from inside the cabinet.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eToolless Mounting and Built-In Network Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTwo mounting pegs let the strip go in without tools, and network management is standard - Web, Telnet, SNMP and SSH, with EcoStruxure IT reporting and a one-year Secure NMC subscription included. Serial, USB and CAN ports round out the connectivity. The outlets also support APC locking input cords, so a cable cannot be nudged out of a socket during a rack tidy.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP8853 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Metered Rack PDU, 0U, 1PH, 7.4 kW 230 V 32 A, 36 C13 and 6 C19 outlets, IEC 309 2P+E cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP8853\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMetered Rack Power Distribution Unit (PDU), 2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eZero U (0U), vertical side mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 32 A 2P+E (3-pin) attached cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e220-240 VAC, +6% \/ -10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e32 A per phase; 16 A maximum per bank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacity\u003c\/td\u003e\n\u003ctd\u003e7,400 VA (7.4 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eThirty-six (36) IEC 60320 C13 and six (6) IEC 60320 C19 - 42 outlets total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per C13 Outlet\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per C19 Outlet\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003ctd\u003eTwo (2) 16 A single-pole hydraulic-magnetic circuit breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Locking\u003c\/td\u003e\n\u003ctd\u003eCompatible with APC locking input cords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMetering, Switching \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eDevice, phase and breaker-bank level metering of current, power and voltage. Not metered per outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3% (amps, volts, kW, kWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Display\u003c\/td\u003e\n\u003ctd\u003eInteractive LCD showing current, power and voltage; field-replaceable display module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd\u003eNone - this is a Metered model, not a Switched one\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eBuilt in as standard - no separate card required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interfaces\u003c\/td\u003e\n\u003ctd\u003eWeb, Telnet, SNMP, SSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Platform\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure IT (formerly InfraStruxure Central). A one-year Secure Network Management Card subscription is included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Ports\u003c\/td\u003e\n\u003ctd\u003eSerial, USB, CAN and environmental sensor ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Sensors\u003c\/td\u003e\n\u003ctd\u003eAP9335T (temperature) or AP9335TH (temperature and humidity), sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided - no surge suppression is specified for this product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e1,791 x 56 x 44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e6.93 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e8.56 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eToolless, via two mounting pegs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 15,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Approvals\u003c\/td\u003e\n\u003ctd\u003eVDE; IEC 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e0731304277019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Load Planning\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Thirty-six IEC C13 outlets at 10 A each for C14-corded\nservers, switches and appliances, plus six IEC C19 outlets at 16 A each for C20-corded blade chassis,\nstorage shelves and core switches. Forty-two outlets is enough to cable an entire full-height rack from one\nstrip, and the outlets accept APC locking input cords so connections cannot be nudged loose.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLoad planning and banks.\u003c\/strong\u003e 32 A input, 7,400 VA total, split across two 16 A\nbanks each behind its own hydraulic-magnetic breaker. Metering is per device, per phase and per breaker bank, to\n±3%, so balancing the two banks is a matter of reading the LCD rather than guessing. Forty-two outlets on\n7.4 kW works out to modest per-outlet draw - the sockets are there for reach and tidiness, not so every one\ncan pull its maximum.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e A 0U vertical strip 1,791 mm long, 56 mm wide and 44 mm deep,\nweighing 6.93 kg. It mounts without tools on two pegs in the rear vertical channel and consumes no rack units.\nConfirm your enclosure is tall enough and has the channel to take a 1.79 m strip - this is the longest unit\nin this range, longer than the 1,619 mm Basic strips. In a short or wall-mount cabinet, the 2U\n\u003ca href=\"\/products\/apc-rack-pdu-metered-2u-32a-230v-12-c13-4-c19\"\u003eAP7822B\u003c\/a\u003e gives the same 32 A capacity horizontally.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeeding it.\u003c\/strong\u003e A captive 3.0 m IEC 60309 32 A 2P+E commando cord. The rack needs a\nmatching 32 A commando socket on a dedicated circuit - a fixed electrical installation, so budget for an\nelectrician if one is not already in place.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eManagement and sensors.\u003c\/strong\u003e Web, Telnet, SNMP and SSH are built in with EcoStruxure IT reporting\nand a one-year Secure NMC subscription, and there are serial, USB and CAN ports as well. The environmental sensor\nport takes the AP9335T temperature probe or the\n\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH temperature and humidity sensor\u003c\/a\u003e - the latter is the one most Singapore\nsites want, given how quickly rack inlet temperature and humidity both matter here.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat it does not do.\u003c\/strong\u003e No outlet switching - you cannot power-cycle a device remotely from this\nPDU; that is the Switched range, such as the \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e. No per-outlet metering\neither, only device, phase and bank level. And no surge protection - that is a UPS function.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Metered and Switched Rack PDU Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC NetShelter Metered Rack PDU (AP8853) with 3.0 m IEC 60309 32 A input cord\u003c\/li\u003e\n\u003cli\u003eRack mounting brackets\u003c\/li\u003e\n\u003cli\u003eSerial cable\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003cli\u003eSafety guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMetered \u0026amp; Switched Rack PDU Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 10 A, 2.3 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C14 inlet, 2.4 m cord supplied\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, 2.4 m cord supplied\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, no cord supplied\u003c\/td\u003e\n\u003ctd\u003e(18) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-metered-2u-32a-230v-12-c13-4-c19\"\u003eAP7822B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(12) C13, (4) C19\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP8853 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMetered\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 32 A, 7.4 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCaptive IEC 60309 32 A cord\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(36) C13, (6) C19\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Sensor (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335TH\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAPC Temperature \u0026amp; Humidity Sensor\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eAPC also makes a temperature-only probe, the AP9335T, which this PDU's sensor port accepts. We do not hold it as a stock line - ask us and we will quote it.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP8853. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-3439_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Metered Rack PDU AP8853 - Overview and Specifications (990-3439_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/AP8853\/apc-netshelter-metered-rack-pdu-0u-1ph-7-4kw-230v-32a-36-c13-and-6-c19-outlets-iec-309-2p+e-cord\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric AP8853 product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/id\/en\/faqs\/FAQ000277528\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric Rack PDU warranty policy (FAQ000277528)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP8853\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eTwo listings in our store share the title \"APC NetShelter Metered Rack PDU\" - which one is this?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis is AP8853, the 32 A model: 7.4 kW, forty-two outlets (36 C13 and 6 C19), a 1,791 mm strip fed by a captive IEC 60309 commando cord, 6.93 kg. The other listing is \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e, the 16 A model: 3.7 kW, twenty outlets (18 C13 and 2 C19), a 902 mm strip with a C20 inlet and no attached cord, 2.93 kg. They are quite different products despite sharing a title.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs it metered per outlet?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. The AP8853 meters at device, phase and breaker-bank level - current, power and voltage, to ±3% - and shows it on an interactive LCD as well as over the network. Per-outlet measurement is a different product class. Bank-level metering is what you need for load balancing and capacity planning.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan I add temperature and humidity monitoring?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. The AP8853 has an environmental sensor port that takes the AP9335T temperature probe or the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH temperature and humidity sensor\u003c\/a\u003e, sold separately. Given Singapore's ambient conditions and what a failed cooling unit does to a closed cabinet, this is worth adding when you order the PDU.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat supply does it need?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA 32 A IEC 60309 2P+E commando socket on a dedicated circuit. The 3 m cord is captive, so nothing to buy, but the socket is a fixed electrical installation. If you do not have one, the 16 A \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e uses an ordinary C20 inlet instead.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Neither Schneider's specification guide nor the product data sheet for the AP8853 contains a surge section, joule rating or clamping figure. Surge suppression is a UPS function, not a PDU one.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan it switch outlets off remotely?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo - Metered means measurement, not control. To power-cycle a hung device remotely you want a Switched model such as the \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e. A common arrangement is a large metered strip for rack-wide distribution plus a small switched PDU for the network equipment you most often need to reboot.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow long is the strip and will it fit my rack?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1,791 mm - the longest unit in this range, sized for a full-height enclosure, and 6.93 kg. Measure the vertical channel before ordering. If the cabinet is short, the 2U \u003ca href=\"\/products\/apc-rack-pdu-metered-2u-32a-230v-12-c13-4-c19\"\u003eAP7822B\u003c\/a\u003e offers the same 32 A and 7.4 kW horizontally, at the cost of two rack units and with sixteen outlets instead of forty-two.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Metered Rack PDU AP8853 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the AP8853 with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43075122364580,"sku":"AP8853","price":900.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_0430ab54-41b5-4598-95bc-e6d086358bbd.png?v=1789720613"},{"product_id":"apc-netshelter-switched-rack-pdu-ap7920b","title":"APC NetShelter Switched Rack PDU","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Switched Rack PDU, 1U, 1 Phase, 2.3kW 230V 10A, (8) C13 Outlets, C14 Cord (AP7920B) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eReboot a Hung Device Without Driving to the Site\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Switched Rack PDU AP7920B gives you individual on\/off control of each of its eight IEC C13 outlets over the network. When a switch, router or appliance locks up at 2 a.m., you power-cycle the outlet from a browser rather than sending someone to the comms room. For a Singapore SME with equipment in a co-location cage or a branch office, that single capability usually pays for the PDU.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eControlled Power-Up Sequencing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOutlets can be brought up in a defined order with configurable delays, so a rack restarting after an outage does not slam every power supply on at once - and so dependent equipment comes up after the infrastructure it relies on. It is a small feature that prevents a specific and common kind of post-outage mess.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e2.3 kW at 230 V Through a C14 Inlet\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRated 10 A and 2.3 kW on a 230 V IEC supply (the 12 A \/ 2.5 kW figure that also appears on the box is the UL-market rating at 208 V), the AP7920B is fed through an IEC C14 inlet on the front of the unit, with a 2.4 m cord. That means it plugs straight into an ordinary C13 outlet on a UPS or upstream PDU - no commando socket, no electrician.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eNetwork Management and Load Metering as Standard\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWeb, Telnet, SNMP and SSH access are built in, with EcoStruxure IT compatibility and a one-year Secure NMC subscription included, and current is measured to ±5%. In a 1U chassis 44.5 mm high and 108 mm deep weighing 2.26 kg, it adds remote control and visibility to a rack without consuming meaningful space.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP7920B Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Switched Rack PDU, 1U, 1PH, 2.3 kW 230 V 10 A or 2.5 kW 208 V 12 A, 8 C13 outlets, C14 cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP7920B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSwitched Rack Power Distribution Unit (PDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e1U, 19-inch horizontal rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet, front of unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e2.4 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e208-230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e200-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e10 A total and 10 A per outlet (VDE \/ IEC markets, including Singapore); 12 A total and 12 A per outlet (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacity\u003c\/td\u003e\n\u003ctd\u003e2.3 kW at 230 V; 2.5 kW at 208 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eEight (8) IEC 60320 C13\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMetering, Switching \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd\u003eIndividual on\/off control of every outlet, remotely over the network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Sequencing\u003c\/td\u003e\n\u003ctd\u003eConfigurable power-up and power-down sequences with per-outlet delays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% (amps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eBuilt in as standard - no separate card required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interfaces\u003c\/td\u003e\n\u003ctd\u003eWeb, Telnet, SNMP, SSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Platform\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure IT; EcoStruxure IT Data Center Expert. A one-year Secure Network Management Card subscription is included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided - no surge suppression is specified for this product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e44.5 x 444.5 x 108.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e2.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 15,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Approvals\u003c\/td\u003e\n\u003ctd\u003eUL Listed, cUL Listed, CE, VDE, EAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A, ICES-003, VCCI, EN 55022, EN 55024, AS\/NZS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Load Planning\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Eight IEC C13 outlets taking standard C14 equipment cords -\nswitches, routers, firewalls, appliances, small servers, media converters. There are no C19 outlets, and at\n10 A total this is deliberately a light-duty unit: it is designed for the network equipment you most want to\nreboot remotely, not for a rack of power-hungry servers.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLoad planning.\u003c\/strong\u003e On a Singapore 230 V supply the applicable figure is the IEC\/VDE one:\n10 A total and 10 A per outlet, giving 2.3 kW. The 12 A \/ 2.5 kW figure that also appears\non the box is the UL-market rating at 208 V, not extra headroom available to you here - do not plan\nagainst it. Eight outlets sharing\n10 A means roughly 1.2 A each on average, which is ample for network gear and thin for servers. If you\nneed more headroom, the \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e is the same idea at 16 A and 3.7 kW.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e 1U high, 444.5 mm wide, 108 mm deep, 2.26 kg - it fits any 19-inch\nrack including shallow comms cabinets.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeeding it.\u003c\/strong\u003e The inlet is IEC C14 on the front of the unit, with a 2.4 m cord. That is\nthe easiest supply arrangement in this range: it plugs into any ordinary C13 outlet on a UPS or upstream\nPDU, so no dedicated circuit and no electrician are required. Feeding it from a UPS is the sensible arrangement -\nthe PDU switches power, it does not store it.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eManagement.\u003c\/strong\u003e Web, Telnet, SNMP and SSH are built in, no card needed, with EcoStruxure IT\ncompatibility and a one-year Secure NMC subscription included. Schneider does not document an environmental\nsensor port on this model, so we do not claim one.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat it does not do.\u003c\/strong\u003e No surge protection - Schneider's specification guide for this model\ncontains no surge section at all. Being a\nswitched PDU it also has no battery: it cannot keep anything running through a power cut, only control what is\npowered when supply is present.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Metered and Switched Rack PDU Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSchneider does not publish a definitive package contents list for the AP7920B, so rather than guess we have not listed one. Ask us and we will confirm the full box contents with the distributor before you order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMetered \u0026amp; Switched Rack PDU Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP7920B (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitched\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 10 A, 2.3 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC C14 inlet, 2.4 m cord supplied\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(8) C13\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, 2.4 m cord supplied\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8858\"\u003eAP8858\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, no cord supplied\u003c\/td\u003e\n\u003ctd\u003e(18) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-metered-2u-32a-230v-12-c13-4-c19\"\u003eAP7822B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(12) C13, (4) C19\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(36) C13, (6) C19\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP7920B. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/ca\/en\/download\/document\/990-5829_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Switched Rack PDU AP7920B - Overview and Specifications (990-5829_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/product\/AP7920B\/apc-netshelter-switched-rack-pdu-1u-1ph-2-3kw-230v-10a-or-2-5kw-208v-12a-8-c13-outlets-c14-cord\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric AP7920B product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/id\/en\/faqs\/FAQ000277528\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric Rack PDU warranty policy (FAQ000277528)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP7920B\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat does \"Switched\" mean on a Rack PDU?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEach outlet can be turned on and off independently over the network. You can reboot a hung device remotely, shut down an outlet that should not be live, and define the order and delays in which outlets come up after a power failure. A Metered PDU shows you the load but cannot switch; a Basic PDU does neither.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs 10 A or 12 A the right figure for Singapore?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e10 A, giving 2.3 kW. Schneider publishes 12 A \/ 2.5 kW under UL rules for 208 V markets and 10 A \/ 2.3 kW under VDE and IEC rules. Singapore follows the IEC convention, so plan against 10 A total across all eight outlets - the UL number is not extra headroom.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDo I need a network management card for it?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Web, Telnet, SNMP and SSH access are built in, and a one-year Secure Network Management Card subscription is included. The AP9640 and AP9641 cards in our catalogue are Smart-UPS accessories and are not needed for, or fitted to, this PDU.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Schneider's specification guide for the AP7920B has no surge section, joule rating or clamping figure. Surge and dip protection belongs to a UPS upstream of the PDU, not to the PDU itself.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does it compare with the AP7921B?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSame 1U chassis, same eight C13 outlets, and the same built-in switching and network management. The difference is the input and the capacity: the AP7920B is 10 A \/ 2.3 kW through a C14 inlet, so it plugs into an ordinary C13 socket; the \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e is 16 A \/ 3.7 kW through a C20 inlet, needing a 16 A supply cord. Choose on total draw.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan I power my whole rack from it?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOnly a light one. Eight outlets sharing 10 A works well for switches, routers, firewalls and appliances - the equipment you most want to reboot remotely. A rack of servers will exceed 10 A quickly; for that, use a larger metered PDU for distribution and reserve a switched PDU for the network devices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs the AP7920B the current model?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes - it is Schneider's named replacement for the earlier AP7920, which was discontinued in August 2021. If you have AP7920 units in service, the AP7920B is the like-for-like successor.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Switched Rack PDU AP7920B sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the AP7920B with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43075188293796,"sku":"AP7920B","price":885.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_071f5716-5dc6-469f-a7d7-b2de9600fc31.jpg?v=1789720646"},{"product_id":"apc-replacement-battery-cartridge-117-apcrbc117","title":"APC Replacement Battery Cartridge #117","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Replacement Battery Cartridge #117 for Smart-UPS X, 120V 5Ah Lead-Acid Battery (APCRBC117) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eGenuine APC Replacement Battery Cartridge #117\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC Replacement Battery Cartridge #117 (APCRBC117) is Schneider Electric's own replacement pack for the 2200 VA and 3000 VA Smart-UPS X rack models. It is a 120 V DC assembly of ten 5 Ah battery blocks in series, supplied complete with connectors fitted, and at 22.27 kg net it is one of the heaviest cartridges in the APC range — a two-person lift and a freight consideration, not a courier envelope. Fitting the genuine cartridge returns the unit to its designed backup capacity and keeps any argument about third-party packs and warranty cover off the table.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy UPS Batteries Need Replacing in Singapore\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSealed lead-acid cells age faster in heat, and a comms cabinet or server room running warm will shorten a cartridge's working life well before its calendar age suggests. Schneider rates this cartridge for operation from 0 to 40 °C at up to 95% relative humidity, so a well-ventilated, air-conditioned rack is doing real work for your battery budget. The failure mode is the dangerous part: a UPS with a tired battery still shows a healthy front panel and still passes mains through, then drops the load the moment a PUB supply dip or a storm-season brownout actually arrives. If your unit has started reporting a battery fault, or has simply been in service for several years, replace the cartridge before you find out the hard way.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eExact-Fit Cartridge for Smart-UPS X 2200VA and 3000VA Rack Models\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Smart-UPS X range splits by battery bus voltage: the 750, 1000 and 1500 VA models run a 48 V string, while the 2200 and 3000 VA models run 120 V. That is why this cartridge weighs more than twice what the APCRBC115 does, and it is why the two are in no sense interchangeable. Schneider's own Smart-UPS X battery replacement guide covers RBC 117 for the 2000 to 3000 VA units and assigns a different part, RBC 118, to the matching external battery packs — so a cartridge bought for the UPS will not serve an XLBP pack. Read the part number from the label on the rear of the UPS and send it to us if you would like it checked before you order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLocal Singapore Stock, GST Invoice and Local Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSourceIT holds APC replacement cartridges in Singapore, so a failed battery does not mean a multi-week import wait on a unit that is currently protecting nothing. Every order ships with a GST invoice for your accounts team and carries local Singapore warranty support, and we can quote the cartridge alongside the matching UPS, rack PDU or network management card on a single purchase order. We can also look at arranging collection of the exhausted cartridge for proper lead-acid recycling when the replacement is delivered — ask for that when you order.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC Replacement Battery Cartridge #117 (APCRBC117) Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAPC Replacement Battery Cartridge (RBC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAPCRBC117\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Replacement Battery Cartridge #117 with 2 Year Warranty. The North American catalogue lists the same part as \"APC Replacement Battery Cartridge for Smart-UPS Line Interactive, 120V 5Ah lead-acid battery, 2-year repair or replace warranty\".\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003e2 years repair or replace, stated worldwide with no regional variation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupported locally by SourceIT Pte Ltd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Code (as published by APC)\u003c\/td\u003e\n\u003ctd\u003e731304282679\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBattery Specifications\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Chemistry\u003c\/td\u003e\n\u003ctd\u003eSealed lead-acid battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e120 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Blocks per String\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e5 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Service Life\u003c\/td\u003e\n\u003ctd\u003eNot published by Schneider for this part number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C, 0 to 95% relative humidity, 0 to 10,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Environment\u003c\/td\u003e\n\u003ctd\u003e-15 to 45 °C, 0 to 95% relative humidity, 0 to 15,240 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e76 x 203 x 584 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e22.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e25.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimensions\u003c\/td\u003e\n\u003ctd\u003e228 x 393 x 761 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eNot rack-mountable — the cartridge is fitted inside the UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003ePro-active compliance (product out of EU RoHS legal scope)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Footprint\u003c\/td\u003e\n\u003ctd\u003e209 kg CO2 eq. over the product lifecycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eEvery figure above is taken from Schneider Electric's own published documentation for this exact part number. Where Schneider does not publish a value, the row says so rather than carrying a figure borrowed from a similar cartridge — APC ratings differ between parts that look identical.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eUPS models this cartridge is specified for.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-2200va-rack-tower-lcd-200-240v-smx2200rmhv2u\"\u003eSMX2200RMHV2U\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS X 2200VA Rack\/Tower LCD 200-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-3000va-rack-tower-lcd-200-240v-smx3000rmhv2u\"\u003eSMX3000RMHV2U\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS X 3000VA Rack\/Tower LCD 200-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eSchneider's Smart-UPS X battery replacement guide covers RBC 117 for Smart-UPS X-Series 2000 to 3000 VA units generally. The matching network-card builds sold here — \u003ca href=\"\/products\/apc-smart-ups-x-2200va-lcd-200-240v-with-network-card-smx2200r2hvnc\"\u003eSMX2200R2HVNC\u003c\/a\u003e and \u003ca href=\"\/products\/apc-smart-ups-x-3000va-rack-tower-lcd-ups-w-network-card-smx3000rmhv2unc\"\u003eSMX3000RMHV2UNC\u003c\/a\u003e — are the same chassis with a network management card fitted, and are listed by resellers as taking the same cartridge, but Schneider does not name them in a document we can cite. Send us the model number and we will confirm before you order rather than have you take that on trust.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this cartridge does not fit.\u003c\/strong\u003e Schneider assigns RBC 118, not this part, to the Smart-UPS X external battery packs. If you are re-celling an \u003ca href=\"\/products\/apc-smart-ups-x-battery-pack-for-extended-runtime-smx120rmbp2u\"\u003eSMX120RMBP2U\u003c\/a\u003e or an \u003ca href=\"\/products\/apc-smart-ups-x-120v-short-depth-ebb\"\u003eSMX120BP\u003c\/a\u003e pack rather than the UPS itself, ask us first — Schneider does not publish a cartridge part number on those pack records, and we would rather check it with the distributor than guess.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical fit.\u003c\/strong\u003e Schneider rates this cartridge at 120 V DC, ten 5 Ah blocks in series. A UPS will only accept the cartridge built for it: the charger, the runtime calculation and the low-battery cut-off are all set for a specific pack, so a cartridge of the wrong voltage will either be rejected or damaged.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRuntime after replacement.\u003c\/strong\u003e A new cartridge restores the runtime the UPS was rated for when new; it does not add runtime beyond that. How long that actually is depends entirely on how heavily the UPS is loaded — a unit at a quarter load runs for considerably longer than the same unit near its rated output. Schneider does not publish runtime figures against the cartridge itself, only against the UPS, so if you need a runtime target for a specific rack load, send us the load in watts and the UPS model and we will size it properly rather than quote a number that will not hold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation.\u003c\/strong\u003e The cartridge is supplied fully assembled with its connectors already fitted, so replacement is a slide-out, slide-in operation rather than a wiring job. Schneider does not publish a statement about whether this particular cartridge may be changed with the UPS energised, so follow the installation guide that ships in the box for the correct sequence on your model, and treat the pack as live: these are high-current lead-acid assemblies and a shorted terminal is a genuine hazard. If you would rather not do it in-house, ask us and we will look at arranging it for you.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; RBC Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the Box\u003c\/h4\u003e\n\u003cp\u003eThe cartridge is supplied fully assembled with all required connectors pre-fitted. Schneider does not publish an itemised package contents list for this part number, so we do not invent one.\u003c\/p\u003e\n\u003ch4\u003eAPC Smart-UPS X Replacement Cartridges Stocked by SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-115-apcrbc115\"\u003eAPCRBC115\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS X 1500VA 2U rack (SMX1500RMI2U, SMX1500RMI2UNC), and two per SMX48RMBP2U battery pack\u003cbr\u003e48 V, 9 Ah blocks · 10.82 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-116-apcrbc116\"\u003eAPCRBC116\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS X 750VA and 1000VA (SMX750I, SMX1000I)\u003cbr\u003e48 V · 10.45 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAPCRBC117 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS X 2200VA and 3000VA 2U rack (SMX2200RMHV2U, SMX3000RMHV2U)\u003cbr\u003e120 V, 5 Ah, 10 blocks · 22.27 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-143-apcrbc143\"\u003eAPCRBC143\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS X 120 V cartridge — Schneider does not publish the model list for this part\u003cbr\u003e120 V, 5 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMatching UPS Models\u003c\/h4\u003e\n\u003cp\u003eIf you are replacing the UPS rather than the battery, or adding a second unit, these are the models this cartridge is specified for:\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-2200va-rack-tower-lcd-200-240v-smx2200rmhv2u\"\u003eSMX2200RMHV2U\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS X 2200VA Rack\/Tower LCD 200-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-x-3000va-rack-tower-lcd-200-240v-smx3000rmhv2u\"\u003eSMX3000RMHV2U\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS X 3000VA Rack\/Tower LCD 200-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eBecause this cartridge weighs 22.27 kg net and ships at 25.18 kg, it is a palletised or two-person delivery rather than a parcel. Tell us the delivery address and floor when you order and we will arrange it properly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering notes.\u003c\/strong\u003e Quote the part number APCRBC117 on your purchase order — the cartridge number, not the UPS model, is what determines what ships. This cartridge is a lead-acid assembly and travels as such: net weights across the APC RBC range run from under 3 kg to over 30 kg, so check the physical specifications above before you arrange a courier. We can supply the cartridge on its own, or alongside a network management card, rack PDU or a replacement UPS on a single GST invoice.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.se.com\/il\/en\/product\/APCRBC117\/apc-replacement-battery-cartridge-117\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for APCRBC117\u003c\/a\u003e — official product identity, environmental data and document library (international catalogue)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/nz\/en\/download\/document\/SPD_EALN-7XAJJB_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eSmart-UPS X-Series Battery Replacement — user guide (covers RBC 117 for 2000-3000 VA units)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/SPD_EALN-7TWQ64_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eInstallation guide — Smart-UPS X Tower\/Rack-Mount 2U 2000\/2200\/3000 VA\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/th\/en\/download\/document\/SDS_AL_APCRBC_LEAD_ACID_NAM_EN\" target=\"_blank\" rel=\"noopener\"\u003eProduct Safety Data Sheet — APC rechargeable lead-acid RBC and battery packs\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider Electric serves its PDF datasheets from a download host that redirects and does not reliably return the document you asked for, so we do not publish direct PDF links here — a link that hands you another model's datasheet is worse than no link at all. If you need the signed product data sheet, the installation guide or a written confirmation of fitment for your unit, email us the UPS model number and we will send the current document across.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC Replacement Battery Cartridge #117 (APCRBC117)\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhich APC UPS models does the APCRBC117 fit?\u003c\/h4\u003e\n\u003cp\u003eSchneider specifies it for the Smart-UPS X 2200 VA and 3000 VA 2U rack models — SMX2200RMHV2U and SMX3000RMHV2U in the range sold here — and its battery replacement guide covers the part for Smart-UPS X-Series 2000 to 3000 VA units generally. It does not fit the 750, 1000 or 1500 VA models, which run a 48 V battery string instead of 120 V.\u003c\/p\u003e\n\u003ch4\u003eDoes the APCRBC117 fit the Smart-UPS X external battery packs?\u003c\/h4\u003e\n\u003cp\u003eNo. Schneider's battery replacement guide assigns RBC 118 to the Smart-UPS X extended-runtime battery packs and RBC 117 to the UPS itself. The two are different parts and the packs are a separate conversation — contact us with the pack model number before ordering anything.\u003c\/p\u003e\n\u003ch4\u003eWhy is this cartridge so much heavier than the other Smart-UPS X cartridges?\u003c\/h4\u003e\n\u003cp\u003eBecause it is a 120 V string of ten battery blocks rather than a 48 V string of four. Net weight is 22.27 kg and shipping weight 25.18 kg, so treat it as a two-person lift and a freight item. Any listing advertising a 3 kg cartridge for a 2200 or 3000 VA Smart-UPS X is describing something else.\u003c\/p\u003e\n\u003ch4\u003eHow do I make sure I am ordering the right cartridge?\u003c\/h4\u003e\n\u003cp\u003eRead the model number off the label on the rear or side of the UPS and select against that, never against the part number of the battery already inside it and never against the VA rating alone. Schneider says the same thing on its \u003ca href=\"https:\/\/www.se.com\/us\/en\/work\/products\/tools\/ups-replacement-battery-selector\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC UPS Replacement Battery Cartridge Selector Tool\u003c\/a\u003e: two units of identical capacity in tower and rack form take different cartridges, and a SmartConnect or network-card build often differs from the standard build of the same model. Send us the model number and we will confirm the correct cartridge in writing before you order.\u003c\/p\u003e\n\u003ch4\u003eCan I fit the cartridge myself?\u003c\/h4\u003e\n\u003cp\u003eMechanically, yes. The cartridge ships fully assembled with its connectors already fitted, so it is a slide-out, slide-in job that needs no wiring and, on most models, no tools. Whether it can be changed with the UPS still running depends on the model, and Schneider does not publish that statement for this cartridge, so follow the installation guide in the box for the correct sequence rather than assuming either way. Treat the pack as live throughout — it is a high-current lead-acid assembly. If the unit is protecting something you would rather not gamble on, ask us about arranging the replacement.\u003c\/p\u003e\n\u003ch4\u003eHow long should the cartridge last?\u003c\/h4\u003e\n\u003cp\u003eSchneider does not publish a service-life figure against this particular part number. Its general guidance for sealed lead-acid replacement cartridges is three to five years, and in Singapore the climate is the deciding factor: cells age markedly faster when they run warm, so a unit in an air-conditioned rack will comfortably reach the top of that range while one in a hot riser or an unventilated cabinet may not. Replace on age and on the UPS's own battery-fault warning rather than waiting for an outage to test it.\u003c\/p\u003e\n\u003ch4\u003eWhat do I do with the old cartridge?\u003c\/h4\u003e\n\u003cp\u003eDo not put it in general waste. A UPS cartridge is a sealed lead-acid assembly and is regulated waste in Singapore. Schneider supplies battery recycling information with the cartridge, and SourceIT can look at arranging collection of the exhausted pack for proper recycling when the replacement is delivered — tell us when you order so it can be scheduled with the delivery.\u003c\/p\u003e\n\u003ch4\u003eIs this a genuine APC part, and what does the warranty cover?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC Replacement Battery Cartridge #117 (APCRBC117) sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the APCRBC117 with a 2-year manufacturer warranty, stated as 2 years repair or replace. Schneider publishes this term worldwide with no regional variation, so the Singapore figure is the same 2 years quoted elsewhere — unlike some APC UPS families, where the European figure is higher and does not apply to a Singapore supply.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43075222044836,"sku":"APCRBC117","price":875.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_7caffa9f-5785-419c-a0c3-759f60d16a90.jpg?v=1789720670"},{"product_id":"apc-replacement-battery-cartridge-43-rbc43","title":"APC Replacement Battery Cartridge #43","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Replacement Battery Cartridge #43 for Smart-UPS Line Interactive, 48V 10Ah Lead-Acid Battery (RBC43) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eGenuine APC Replacement Battery Cartridge #43\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC Replacement Battery Cartridge #43 (RBC43) is the manufacturer's own replacement pack for the SMT2200RMI2UC and SMT3000RMI2UC, and for the other APC units that specify this cartridge number. It arrives as a complete sealed lead-acid assembly with the correct connectors already fitted and, where the design calls for one, the metal battery tray, rated by Schneider Electric at 48 V DC, 10 Ah. Fitting the genuine cartridge returns the unit to its designed backup capacity, and it keeps the question of whether a third-party pack affects your UPS warranty cover off the table entirely.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy UPS Batteries Need Replacing in Singapore\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSealed lead-acid cells age faster in heat, and a comms cabinet or server room running warm will shorten a cartridge's working life well before its calendar age suggests. Schneider rates this cartridge for operation from 0 to 40 °C at up to 95% relative humidity, so a well-ventilated, air-conditioned rack is doing real work for your battery budget. The failure mode is the dangerous part: a UPS with a tired battery still shows a healthy front panel and still passes mains through, then drops the load the moment a PUB supply dip or a storm-season brownout actually arrives. If your unit has started reporting a battery fault, or has simply been in service for several years, replace the cartridge before you find out the hard way.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eExact-Fit Cartridge for the SMT2200RMI2UC and SMT3000RMI2UC\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAPC cartridge selection follows the chassis, not the VA rating: two Smart-UPS units of identical capacity in tower and rack form take different cartridges, and a SmartConnect build often differs from the standard build of the same model. This part is the one Schneider names for the model shown above. Read the part number from the label on the rear of the UPS rather than working from the capacity alone, and send it to us if you would like it checked before you order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLocal Singapore Stock, GST Invoice and Local Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSourceIT holds APC replacement cartridges in Singapore, so a failed battery does not mean a multi-week import wait on a unit that is currently protecting nothing. Every order ships with a GST invoice for your accounts team and carries local Singapore warranty support, and we can quote the cartridge together with the matching UPS, rack PDU or network management card on a single purchase order. We can also arrange collection of the exhausted cartridge for proper lead-acid recycling when the replacement is delivered — ask for that when you order.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC Replacement Battery Cartridge #43 (RBC43) Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAPC Replacement Battery Cartridge (RBC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eRBC43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Replacement Battery Cartridge for Smart-UPS Line Interactive, 48V 10Ah lead-acid battery, 2-year repair or replace warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003e2 years repair or replace, stated worldwide with no regional variation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupported locally by SourceIT Pte Ltd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBattery Specifications\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Chemistry\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed lead-acid (VRLA) with suspended electrolyte, leak-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e10 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Capacity\u003c\/td\u003e\n\u003ctd\u003e480 VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Service Life\u003c\/td\u003e\n\u003ctd\u003e3 to 5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C, 0 to 95% relative humidity (non-condensing), 0 to 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Environment\u003c\/td\u003e\n\u003ctd\u003e-15 to 45 °C, 0 to 95% relative humidity (non-condensing), 0 to 15,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e76 x 216 x 533 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e19.09 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e20.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eRoHS compliant. REACh declaration states the product contains no SVHCs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003e136 kg CO2 eq. over the product lifecycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eEvery figure above is taken from Schneider Electric's own published documentation for this exact part number. Where Schneider does not publish a value, the row says so rather than carrying a figure borrowed from a similar cartridge — APC ratings differ between parts that look identical.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eUPS models this cartridge is specified for.\u003c\/strong\u003e This is confirmed from the Schneider product data sheets for the SMT2200RMI2UC and SMT3000RMI2UC, both of which name RBC43 as their replacement battery.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-2200va-lcd-rm-2u-230v-with-smartconnect-smt2200rmi2uc\"\u003eSMT2200RMI2UC\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS 2200VA LCD RM 2U 230V with SmartConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-3000va-lcd-rm-2u-230v-with-smartconnect-smt3000rmi2uc\"\u003eSMT3000RMI2UC\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS 3000VA LCD RM 2U 230V with SmartConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eRBC43 is the long-running 2U rack cartridge for this capacity band and is also listed for the legacy SUA2200RM2U, SUA2200RMI2U, SUA3000RM2U, SUA3000RMI2U and SUA3000RMT2U Smart-UPS units and for the SUM1500RMXL2U, SUM1500RMXLI2U, SUM3000RMXL2U, SUM3000RMXLI2U and SUM48RMXLBP2U Smart-UPS RM XL models. It is a rack cartridge throughout — the matching tower models take a different part. Send us the model number from the rear label and we will confirm before you order.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical fit.\u003c\/strong\u003e Schneider rates this cartridge at 48 V DC, 10 Ah. A UPS will only accept the cartridge built for it: the charger, the runtime calculation and the low-battery cut-off are all set for a specific pack, so a cartridge of the wrong voltage or capacity will either be rejected, mis-report runtime, or shorten its own life on the wrong charge profile.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRuntime after replacement.\u003c\/strong\u003e A new cartridge restores the runtime the UPS was rated for when new; it does not add runtime beyond that. How long that actually is depends entirely on how heavily the UPS is loaded — a unit at a quarter load runs for considerably longer than the same unit near its rated output. Schneider does not publish runtime figures against the cartridge itself, only against the UPS, so if you need a runtime target for a specific rack load, send us the load in watts and the UPS model and we will size it properly rather than quote a number that will not hold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation.\u003c\/strong\u003e The cartridge is supplied fully assembled with its connectors already fitted, so replacement is a slide-out, slide-in operation rather than a wiring job. Schneider does not publish a statement about whether this particular cartridge may be changed with the UPS energised, so follow the installation guide that ships in the box for the correct sequence on your model, and treat the pack as live: these are high-current lead-acid assemblies and a shorted terminal is a genuine hazard. If you would rather not do it in-house, ask us and we will look at arranging it for you.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; RBC Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the Box\u003c\/h4\u003e\n\u003cp\u003eAll required connectors pre-fitted; Schneider does not publish a full package contents list for this part number.\u003c\/p\u003e\n\u003ch4\u003eAPC Smart-UPS SMT and SMC Replacement Cartridges Stocked by SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-6-rbc6\"\u003eRBC6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS C 1500VA tower (SMC1500IC)\u003cbr\u003e11 Ah · 7.68 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-7-rbc7\"\u003eRBC7\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 1500VA tower (SMT1500IC)\u003cbr\u003e24 V 17 Ah · 11.68 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRBC43 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 2200\/3000VA 2U rack (SMT2200RMI2UC, SMT3000RMI2UC)\u003cbr\u003e48 V 10 Ah · 19.09 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-48-rbc48\"\u003eRBC48\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 750VA tower (SMT750IC)\u003cbr\u003e24 V 7 Ah · 5.00 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-55-rbc55\"\u003eRBC55\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 2200\/3000VA tower (SMT2200IC, SMT3000IC)\u003cbr\u003e12 V 17 Ah modules · 24.27 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-123-apcrbc123\"\u003eAPCRBC123\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 750VA 2U rack (SMT750RMI2UC)\u003cbr\u003e24 V 7 Ah · 5.21 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-124-apcrbc124\"\u003eAPCRBC124\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS C 1000VA 2U rack (SMC1000I-2UC)\u003cbr\u003e24 V 9 Ah · 5.60 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-132-apcrbc132\"\u003eAPCRBC132\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 1000VA 2U rack, standard build (SMT1000RMI2U)\u003cbr\u003e7.0 Ah · 10.00 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-133-apcrbc133\"\u003eAPCRBC133\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 1500VA 2U rack, standard build (SMT1500RMI2U)\u003cbr\u003e9 Ah · 11.96 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-142-apcrbc142\"\u003eAPCRBC142\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS C 1000VA tower (SMC1000IC)\u003cbr\u003e24 V 9 Ah · 6.01 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-157-apcrbc157\"\u003eAPCRBC157\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS C 1500VA 2U rack and SMT1000RMI2UC SmartConnect\u003cbr\u003e7.0 Ah · 10.00 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-replacement-battery-cartridge-159-apcrbc159\"\u003eAPCRBC159\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart-UPS 1500VA 2U rack, SmartConnect (SMT1500RMI2UC)\u003cbr\u003e9 Ah · 11.96 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMatching UPS Models\u003c\/h4\u003e\n\u003cp\u003eIf you are replacing the UPS rather than the battery, or adding a second unit, these are the models this cartridge is specified for:\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-2200va-lcd-rm-2u-230v-with-smartconnect-smt2200rmi2uc\"\u003eSMT2200RMI2UC\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS 2200VA LCD RM 2U 230V with SmartConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-smart-ups-3000va-lcd-rm-2u-230v-with-smartconnect-smt3000rmi2uc\"\u003eSMT3000RMI2UC\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAPC Smart-UPS 3000VA LCD RM 2U 230V with SmartConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering notes.\u003c\/strong\u003e Quote the part number RBC43 on your purchase order — the cartridge number, not the UPS model, is what determines what ships. This cartridge is a lead-acid assembly and travels as such: check the net weight in the specifications above before arranging a courier, because several cartridges in this range are considerably heavier than they look. We can supply the cartridge on its own, or alongside a network management card, rack PDU or a replacement UPS on a single GST invoice.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/RBC43\/apc-replacement-battery-cartridge-vrla-battery-10ah-48vdc-2year-warranty\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for RBC43\u003c\/a\u003e — official product identity, environmental data and document library\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider Electric serves its PDF datasheets from a download host that redirects and does not reliably return the document you asked for, so we do not publish direct PDF links here — a link that hands you another model's datasheet is worse than no link at all. If you need the signed product data sheet, the installation guide or a written confirmation of fitment for your unit, email us the UPS model number and we will send the current document across.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC Replacement Battery Cartridge #43 (RBC43)\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhich APC UPS models does the RBC43 fit?\u003c\/h4\u003e\n\u003cp\u003eSchneider specifies it for the SMT2200RMI2UC and SMT3000RMI2UC. This is confirmed from the Schneider product data sheets for the SMT2200RMI2UC and SMT3000RMI2UC, both of which name RBC43 as their replacement battery. Selection follows the UPS part number rather than its VA rating, because tower and rack builds of the same capacity take different cartridges. If your model is not named here, send us the part number from the rear label and we will confirm the correct cartridge in writing before you order.\u003c\/p\u003e\n\u003ch4\u003eWhat voltage and capacity is the RBC43?\u003c\/h4\u003e\n\u003cp\u003eSchneider rates it at 48 V DC, 10 Ah. That is the cartridge-level rating, not the rating of one battery block inside it — a distinction worth watching, because several listings elsewhere quote the block figure and make the pack look half its actual size.\u003c\/p\u003e\n\u003ch4\u003eCan I fit the cartridge myself, and can it be done without shutting the UPS down?\u003c\/h4\u003e\n\u003cp\u003eThe cartridge ships fully assembled with its connectors already fitted, so mechanically it is a slide-out, slide-in job that needs no wiring and, on most models, no tools. Whether it can be changed with the UPS still running depends on the model, and Schneider does not publish that statement for this cartridge, so follow the installation guide in the box for the correct sequence rather than assuming either way. Treat the pack as live throughout — it is a high-current lead-acid assembly. If the unit is protecting something you would rather not gamble on, ask us about arranging the replacement.\u003c\/p\u003e\n\u003ch4\u003eHow long should the cartridge last?\u003c\/h4\u003e\n\u003cp\u003eSchneider publishes an expected service life of 3 to 5 years for this cartridge. In practice Singapore's climate is the deciding factor: sealed lead-acid cells age markedly faster when they run warm, so a unit in an air-conditioned rack will comfortably reach the top of that range while one in a hot riser or an unventilated cabinet may not. Schneider rates the cartridge for operation up to the temperature shown in the specifications above; running near that ceiling is exactly what shortens battery life.\u003c\/p\u003e\n\u003ch4\u003eWhat do I do with the old cartridge?\u003c\/h4\u003e\n\u003cp\u003eDo not put it in general waste. A UPS cartridge is a sealed lead-acid assembly and is regulated waste in Singapore. Schneider supplies a battery recycling guide with the cartridge, and SourceIT can arrange collection of the exhausted pack for proper recycling when the replacement is delivered — tell us when you order so it is scheduled with the delivery.\u003c\/p\u003e\n\u003ch4\u003eIs this a genuine APC part, and what does the warranty cover?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC Replacement Battery Cartridge #43 (RBC43) sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the RBC43 with a 2-year manufacturer warranty, stated as 2 years repair or replace. Schneider publishes this term worldwide with no regional variation, so the Singapore figure is the same 2 years quoted elsewhere — unlike some APC UPS families, where the European figure is higher and does not apply to a Singapore supply.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43075230826660,"sku":"RBC43","price":765.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_3aa35d7e-6c5e-49df-985c-8ce7fa359ad8.jpg?v=1789720692"},{"product_id":"apc-back-ups-pro-1600va-960w-tower-230v-br1600mi","title":"APC Back-UPS Pro, 1600VA\/960W, Tower, 230V","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Back-UPS Pro, 1600VA\/960W, Tower, 230V (BR1600MI) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eAPC BR1600MI 1600 VA \/ 960 W UPS for Singapore's 230V \/ 50Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC BR1600MI is a 1600 VA \/ 960 W line-interactive UPS with stepped-approximation output, built for 230 V, 50 Hz supplies — exactly what Singapore's PUB grid delivers. It rides through the short dips, brownouts and momentary interruptions that follow an afternoon thunderstorm, and its Automatic Voltage Regulation corrects high and low mains voltage \u003cem\u003ewithout\u003c\/em\u003e going to battery, so the cells are not cycled every time the supply wanders. Output is 8 x C13 — 6 battery-backed, 2 surge-only.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStepped-Approximation Output — Check Your PSU Before You Order\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe BR1600MI produces a stepped approximation to a sinewave on battery, which is what the Schneider data sheet states for this exact part number. That is entirely suitable for most desktop PCs, routers, switches, NVRs, POS terminals and comms-cabinet gear. If the load is an active-PFC ATX power supply that is fussy about waveform, specify a sine wave model instead — in the Back-UPS Pro BR range that is the \u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e or \u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e. We would rather tell you that up front than take the return.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutlets, Runtime and Battery Life in a Humid Climate\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOutlets are 6 x IEC 60320 C13 (battery backup and surge protection) plus 2 x IEC 60320 C13 (surge protection only). The surge-only outlets are there for printers, monitors and chargers that do not need backup but do need protection — keeping them off the battery bank is what buys you runtime on the equipment that matters. The battery is a sealed maintenance-free lead-acid (VRLA) cartridge with a 3 to 5 year expected service life. Singapore's heat and humidity are hard on VRLA cells, so plan on a cartridge change inside that window rather than at the end of it; the replacement part is APCRBC166. Schneider does not publish a runtime-versus-load table for the BR1600MI, so we do not print one — runtime depends entirely on how much of the 960 W you actually draw. Tell us your load in watts and we will size it for you.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSME Office, Home Office and Comms-Cabinet Duty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis is a tower unit at 100 mm (H) x 250 mm (W) x 382 mm (D), 10.9 kg — it sits on a desk, under a counter or on the floor of a comms cupboard rather than in a rack, so it costs you no rack U. Everything SourceIT ships is local Singapore stock with a GST invoice and local warranty support — no grey imports, no chasing an overseas RMA.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC BR1600MI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eEvery figure below is taken from the Schneider Electric product page (United Kingdom) and the APC BR1600MI product data sheet as carried by two independent distributor mirrors that agree. Where Schneider does not publish a value for this exact part number, the row is left out rather than filled in from a similar model.\u003c\/p\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eBR1600MI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro, 1600VA\/960W, Tower, 230V, 8x IEC C13 outlets, AVR, LCD, User Replaceable Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro BR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive with Automatic Voltage Regulation (AVR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e1600 VA \/ 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003eRepair or replace; Schneider states 2 years for the rest of the world and 3 years inside the European Community, so Singapore takes the 2-year term\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupported locally by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e960 W \/ 1600 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 1 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform (on battery)\u003c\/td\u003e\n\u003ctd\u003eStepped approximation to a sinewave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003e6 x IEC 60320 C13 (battery backup and surge protection) plus 2 x IEC 60320 C13 (surge protection only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e509 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Filtering\u003c\/td\u003e\n\u003ctd\u003eFull-time multi-pole noise filtering, 10% of IEEE surge let-through, instantaneous response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e176 to 294 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 3 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e10 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003eAutomatic Voltage Regulation (AVR) — corrects high and low mains voltage without switching to battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed maintenance-free lead-acid (VRLA), user replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e9.0 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e16 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC166\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Battery Life\u003c\/td\u003e\n\u003ctd\u003e3 to 5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Runtime\u003c\/td\u003e\n\u003ctd\u003eNo external battery pack is documented for this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Load\u003c\/td\u003e\n\u003ctd\u003eSchneider publishes no runtime-versus-load figures for this model — contact SourceIT with your load in watts for a sizing calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Interface\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Alarms\u003c\/td\u003e\n\u003ctd\u003eAlarm when on battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eNot available on this model — there is no SmartSlot for an internal network management card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e100 mm (H) x 250 mm (W) x 382 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e10.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Mountable\u003c\/td\u003e\n\u003ctd\u003eNo — tower form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-15 to 45 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e45 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, RCM, C-Tick, A-Tick, EAC, TISI, GS Mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe BR1600MI presents 8 x C13 — 6 battery-backed, 2 surge-only. All outlets are IEC 60320 C13, so a standard C13 kettle lead connects a PC, monitor, switch, router or NAS directly. Only the battery-backed outlets carry the load through an outage; the surge-only outlets stay dead when the mains fails, which is the point — put the printer and the monitor there and keep the battery for the machine that must not stop. The unit takes its own supply through an IEC 60320 C14 inlet on a normal 13 A Singapore wall socket — no dedicated circuit and no electrician needed.\u003c\/p\u003e\n\u003ch4\u003eSizing it: VA, watts and how much you can actually load\u003c\/h4\u003e\n\u003cp\u003eThe BR1600MI is rated 1600 VA apparent power and 960 W real power. Size against the \u003cstrong\u003ewatts\u003c\/strong\u003e, not the VA — the watt figure is the one that runs out first on modern IT loads. As a working rule, keep the connected load under about 70% of 960 W so you have headroom for inrush and for the battery ageing. Schneider publishes no runtime table for this model, so any minutes figure you see quoted elsewhere is someone's estimate, not a manufacturer specification. Send us your equipment list and we will work out the real number.\u003c\/p\u003e\n\u003ch4\u003eBattery and replacement cartridge\u003c\/h4\u003e\n\u003cp\u003eThe battery is a sealed maintenance-free lead-acid (VRLA) cartridge, 24 V 9.0 Ah. Typical recharge time is 16 h. The APC replacement cartridge for this model is \u003cstrong\u003eAPCRBC166\u003c\/strong\u003e, which SourceIT can order in; it is not currently a stocked line, so allow lead time. The cartridge is user-replaceable from the front of the unit; APC does not describe this model's battery as swappable while running, so plan a short shutdown for the change.\u003c\/p\u003e\n\u003ch4\u003eRack space and management software\u003c\/h4\u003e\n\u003cp\u003eThis is a tower unit and is not rack mountable, so it consumes no rack U and needs no rail kit. This model has no SmartSlot, so an AP9640 or AP9641 Network Management Card cannot be fitted — if you need SNMP monitoring or an Ethernet-managed UPS, step up to the APC Smart-UPS range and we will quote it. Bundled shutdown software is not documented for this model in the Schneider material we can verify, so we do not claim it; ask us and we will confirm what ships in the current carton.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Back-UPS Pro BR Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cp\u003eSchneider does not itemise the carton contents for this model in the documentation we can verify, so we will not invent a list. What we can tell you is that the unit ships as a complete tower UPS with its battery installed. If the exact carton contents matter for your tender or your install, ask us before you order and we will open a unit and tell you what is actually in it.\u003c\/p\u003e\n\u003ch4\u003eAPC Back-UPS and Back-UPS Pro BR range at SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-500va-300w-tower-230v-br500ci-as\"\u003eBR500CI-AS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS, 500VA \/ 300W tower, 3x C13 — 500 VA \/ 300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-650va\"\u003eBR650MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 650VA \/ 390W tower, 6x C13 — 650 VA \/ 390 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-900va\"\u003eBR900MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 900VA \/ 540W tower, 6x C13 — 900 VA \/ 540 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1200VA \/ 720W tower, 8x C13, sine wave, USB A+C — 1200 VA \/ 720 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-1300va\"\u003eBR1300MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1300VA \/ 780W tower, 8x C13 — 1300 VA \/ 780 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1500va-865w-tower-230v-10x-iec-c13-outlets-avr-lcd-br1500gi\"\u003eBR1500GI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1500VA \/ 865W tower, 10x C13, external pack capable — 1500 VA \/ 865 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBR1600MI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13 — 1600 VA \/ 960 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13, sine wave, USB A+C — 1600 VA \/ 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-external-battery-pack-for-1500va-back-ups-pro-models-br24bpg\"\u003eBR24BPG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro external battery pack, 24 V \/ 372 VAh (for BR1500GI) — Battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMatching replacement battery cartridge\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003eAPCRBC166\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for the BR1600MI — available to order, not a stocked line\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003cp\u003eRail kits and network management cards do not apply to this range: every Back-UPS Pro BR model is a tower with no SmartSlot. For rack-mount or network-managed power protection, ask us about the APC Smart-UPS SMT, SMC and SMX ranges.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eLinks open on Schneider Electric's own site. Each one was checked before publication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/BR1600MI\/apc-backups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets-avr-lcd-user-replaceable-battery\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for the APC BR1600MI\u003c\/a\u003e — official product name, characteristics and the full document list (United Kingdom site)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/SPD_AHUG-B59B4X_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Back-UPS Pro BR650\/900\/1300\/1600MI User Manual (Schneider document library)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's direct datasheet PDF links sit behind a path that blocks automated retrieval, so we link the product page and the document library entry instead — every link above resolves and carries the current document. If you need the datasheet or manual emailed to you as a file for a tender submission, ask us and we will send it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC BR1600MI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 1600 VA and the 960 W rating?\u003c\/h4\u003e\n\u003cp\u003e1600 VA is apparent power and 960 W is real power. Your equipment consumes real power, so the 960 W figure is the one that limits what you can connect. Add up the wattage on the nameplates of everything you intend to back up and keep the total comfortably below 960 W.\u003c\/p\u003e\n\u003ch4\u003eHow long will the BR1600MI run my equipment?\u003c\/h4\u003e\n\u003cp\u003eIt depends entirely on load, and Schneider publishes no runtime table for this model — which is why you will not find minutes quoted on this page. A lightly loaded unit runs for many minutes; one near 960 W runs for a few. Send SourceIT your load in watts and we will calculate it against the published battery rating rather than guess.\u003c\/p\u003e\n\u003ch4\u003eWhat does the \"MI\" in BR1600MI mean?\u003c\/h4\u003e\n\u003cp\u003eIt identifies the build variant. MI is the 230 V IEC-outlet build sold across Asia, the Middle East and Europe, with a stepped-approximation output waveform and no USB charging ports. These suffixes are not interchangeable — outlet counts, waveform and battery cartridge all change with them, so order by the exact part number.\u003c\/p\u003e\n\u003ch4\u003eIs the output a pure sine wave, and will it drive an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eNo. The BR1600MI produces a stepped approximation to a sinewave, as stated in its data sheet. That is fine for most desktops, routers, switches, NVRs and POS gear, but some active-PFC ATX power supplies will alarm or drop out on it. If your load has an active-PFC supply, choose the \u003ca href=\"\/products\/apc-back-ups-pro-1200va-720w-tower-230v-br1200si\"\u003eBR1200SI\u003c\/a\u003e or \u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e instead — both are sine wave.\u003c\/p\u003e\n\u003ch4\u003eWhich replacement battery does it take, and can I fit it myself?\u003c\/h4\u003e\n\u003cp\u003eThe APC replacement battery cartridge for the BR1600MI is \u003cstrong\u003eAPCRBC166\u003c\/strong\u003e, which we can order in on request. It is user-replaceable — no tools beyond a screwdriver and no service call. APC does not describe this model's battery as swappable while running, so shut the unit down for the swap. Expect three to five years of service in an air-conditioned office, and less in a hot, humid comms cupboard.\u003c\/p\u003e\n\u003ch4\u003eCan I rack mount it or add a network management card?\u003c\/h4\u003e\n\u003cp\u003eNo on both counts. The BR1600MI is a tower unit with no rack ears or rail kit option, and the Back-UPS Pro BR range has no SmartSlot, so an AP9640 or AP9641 card cannot be fitted. If you need a 19-inch rack UPS or SNMP monitoring, ask SourceIT about the APC Smart-UPS SMT, SMC and SMX ranges.\u003c\/p\u003e\n\u003ch4\u003eHow does the BR1600MI compare with the BR1600SI?\u003c\/h4\u003e\n\u003cp\u003eThe \u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e is the same 1600 VA \/ 960 W capacity but with true sine wave output and two USB charging ports — the one to pick if the load is an active-PFC power supply. Both are stocked by SourceIT in Singapore — tell us the load and the budget and we will tell you which one is the right buy.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC BR1600MI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the BR1600MI with a 2-year manufacturer warranty. Note that Schneider states three years inside the European Community and two years elsewhere — Singapore takes the two-year term, and any listing quoting three years for this market has copied the European figure.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/dZ-hRA5gJ48\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43075239641252,"sku":"BR1600MI","price":745.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_fa4c48b4-feaa-4fe8-a3c1-83a88eda6665.jpg?v=1789720727"},{"product_id":"apc-back-ups-pro-1200va-720w-tower-230v-br1200si","title":"APC Back-UPS Pro, 1200VA\/720W, Tower, 230V","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Back-UPS Pro, 1200VA\/720W, Tower, 230V (BR1200SI) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eAPC BR1200SI 1200 VA \/ 720 W UPS for Singapore's 230V \/ 50Hz Mains\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC BR1200SI is a 1200 VA \/ 720 W line-interactive UPS with sine wave output, built for 230 V, 50 Hz supplies — exactly what Singapore's PUB grid delivers. It rides through the short dips, brownouts and momentary interruptions that follow an afternoon thunderstorm, and its Automatic Voltage Regulation corrects high and low mains voltage \u003cem\u003ewithout\u003c\/em\u003e going to battery, so the cells are not cycled every time the supply wanders. Output is 8 x C13 — 6 battery-backed, 2 surge-only.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSine Wave Output for Active-PFC Power Supplies\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSchneider's official product name for the BR1200SI states sine wave output. That matters: modern active-PFC ATX power supplies, many NAS units and some network appliances can chatter, alarm or shut down on a stepped waveform. If you are protecting a workstation or small server built in the last few years, the sine wave build is the one to specify. Two USB charging ports — one Type A and one Type C — are built into the front for phones and accessories.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutlets, Runtime and Battery Life in a Humid Climate\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOutlets are 6 x IEC 60320 C13 (battery backup and surge protection) plus 2 x IEC 60320 C13 (surge protection only). The surge-only outlets are there for printers, monitors and chargers that do not need backup but do need protection — keeping them off the battery bank is what buys you runtime on the equipment that matters. The battery is a sealed maintenance-free lead-acid (VRLA) cartridge with a 3 to 5 year expected service life. Singapore's heat and humidity are hard on VRLA cells, so plan on a cartridge change inside that window rather than at the end of it; the replacement part is \u003ca href=\"\/products\/apc-replacement-battery-cartridge-161-apcrbc161\"\u003eAPCRBC161\u003c\/a\u003e. Schneider does not publish a runtime-versus-load table for the BR1200SI, so we do not print one — runtime depends entirely on how much of the 720 W you actually draw. Tell us your load in watts and we will size it for you.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSME Office, Home Office and Comms-Cabinet Duty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis is a tower unit at 260 mm (H) x 100 mm (W) x 368 mm (D), 11.7 kg (13.35 kg packaged) — it sits on a desk, under a counter or on the floor of a comms cupboard rather than in a rack, so it costs you no rack U. An RJ45 10\/100\/1000 Base-T port is built in to protect the data line as well as the power, which is worth having on a fibre-to-the-building service where the router is the thing that keeps dying. Everything SourceIT ships is local Singapore stock with a GST invoice and local warranty support — no grey imports, no chasing an overseas RMA.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC BR1200SI Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eEvery figure below is taken from the Schneider Electric product page (United Kingdom) and the APC BR1200SI product data sheet as carried by two independent distributor mirrors that agree. Where Schneider does not publish a value for this exact part number, the row is left out rather than filled in from a similar model.\u003c\/p\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eBR1200SI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOfficial Product Name\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro, 1200VA\/720W, Tower, 230V, 8x IEC C13 outlets, Sine Wave, AVR, USB Type A + C ports, LCD, User Replaceable Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAPC Back-UPS Pro BR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive with Automatic Voltage Regulation (AVR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e1200 VA \/ 720 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003ctd\u003eRepair or replace; Schneider states 2 years for the rest of the world and 3 years inside the European Community, so Singapore takes the 2-year term\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eSupported locally by SourceIT with a GST invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOutput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Capacity\u003c\/td\u003e\n\u003ctd\u003e720 W \/ 1200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 1 Hz, synchronised to mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform (on battery)\u003c\/td\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connections\u003c\/td\u003e\n\u003ctd\u003e6 x IEC 60320 C13 (battery backup and surge protection) plus 2 x IEC 60320 C13 (surge protection only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e509 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Filtering\u003c\/td\u003e\n\u003ctd\u003eFull-time multi-pole noise filtering, 10% of IEEE surge let-through, instantaneous response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e176 to 294 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 3 Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e10 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C14 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003eAutomatic Voltage Regulation (AVR) — corrects high and low mains voltage without switching to battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBatteries \u0026amp; Runtime\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eSealed maintenance-free lead-acid (VRLA), user replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e9.0 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Rating\u003c\/td\u003e\n\u003ctd\u003e204 VAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Recharge Time\u003c\/td\u003e\n\u003ctd\u003e16 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery Cartridge\u003c\/td\u003e\n\u003ctd\u003eAPCRBC161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected Battery Life\u003c\/td\u003e\n\u003ctd\u003e3 to 5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Runtime\u003c\/td\u003e\n\u003ctd\u003eNo external battery pack is documented for this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Load\u003c\/td\u003e\n\u003ctd\u003eSchneider publishes no runtime-versus-load figures for this model — contact SourceIT with your load in watts for a sizing calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunications \u0026amp; Management\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Interface\u003c\/td\u003e\n\u003ctd\u003eMultifunction LCD status and control console\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Charging Ports\u003c\/td\u003e\n\u003ctd\u003e1 x USB Type A and 1 x USB Type C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Line Protection\u003c\/td\u003e\n\u003ctd\u003eRJ45 10\/100\/1000 Base-T Ethernet data line protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Alarms\u003c\/td\u003e\n\u003ctd\u003eAlarm when on battery, distinctive low-battery alarm, continuous-tone overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eNot available on this model — there is no SmartSlot for an internal network management card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e260 mm (H) x 100 mm (W) x 368 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e11.7 kg (13.35 kg packaged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Mountable\u003c\/td\u003e\n\u003ctd\u003eNo — tower form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-15 to 45 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e45 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e0731304346890\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Runtime\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat you can plug in\u003c\/h4\u003e\n\u003cp\u003eThe BR1200SI presents 8 x C13 — 6 battery-backed, 2 surge-only. All outlets are IEC 60320 C13, so a standard C13 kettle lead connects a PC, monitor, switch, router or NAS directly. Only the battery-backed outlets carry the load through an outage; the surge-only outlets stay dead when the mains fails, which is the point — put the printer and the monitor there and keep the battery for the machine that must not stop. The unit takes its own supply through an IEC 60320 C14 inlet on a normal 13 A Singapore wall socket — no dedicated circuit and no electrician needed.\u003c\/p\u003e\n\u003ch4\u003eSizing it: VA, watts and how much you can actually load\u003c\/h4\u003e\n\u003cp\u003eThe BR1200SI is rated 1200 VA apparent power and 720 W real power. Size against the \u003cstrong\u003ewatts\u003c\/strong\u003e, not the VA — the watt figure is the one that runs out first on modern IT loads. As a working rule, keep the connected load under about 70% of 720 W so you have headroom for inrush and for the battery ageing. Schneider publishes no runtime table for this model, so any minutes figure you see quoted elsewhere is someone's estimate, not a manufacturer specification. Send us your equipment list and we will work out the real number.\u003c\/p\u003e\n\u003ch4\u003eBattery and replacement cartridge\u003c\/h4\u003e\n\u003cp\u003eThe battery is a sealed maintenance-free lead-acid (VRLA) cartridge, 24 V 9.0 Ah. Typical recharge time is 16 h. The APC replacement cartridge for this model is \u003cstrong\u003eAPCRBC161\u003c\/strong\u003e — \u003ca href=\"\/products\/apc-replacement-battery-cartridge-161-apcrbc161\"\u003eAPCRBC161\u003c\/a\u003e is stocked by SourceIT. The cartridge is user-replaceable from the front of the unit; APC does not describe this model's battery as swappable while running, so plan a short shutdown for the change.\u003c\/p\u003e\n\u003ch4\u003eRack space and management software\u003c\/h4\u003e\n\u003cp\u003eThis is a tower unit and is not rack mountable, so it consumes no rack U and needs no rail kit. This model has no SmartSlot, so an AP9640 or AP9641 Network Management Card cannot be fitted — if you need SNMP monitoring or an Ethernet-managed UPS, step up to the APC Smart-UPS range and we will quote it. Bundled shutdown software is not documented for this model in the Schneider material we can verify, so we do not claim it; ask us and we will confirm what ships in the current carton.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Back-UPS Pro BR Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eIn the box\u003c\/h4\u003e\n\u003cp\u003eSchneider does not itemise the carton contents for this model in the documentation we can verify, so we will not invent a list. What we can tell you is that the unit ships as a complete tower UPS with its battery installed. If the exact carton contents matter for your tender or your install, ask us before you order and we will open a unit and tell you what is actually in it.\u003c\/p\u003e\n\u003ch4\u003eAPC Back-UPS and Back-UPS Pro BR range at SourceIT\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-500va-300w-tower-230v-br500ci-as\"\u003eBR500CI-AS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS, 500VA \/ 300W tower, 3x C13 — 500 VA \/ 300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-650va\"\u003eBR650MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 650VA \/ 390W tower, 6x C13 — 650 VA \/ 390 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-900va\"\u003eBR900MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 900VA \/ 540W tower, 6x C13 — 900 VA \/ 540 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBR1200SI (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBack-UPS Pro, 1200VA \/ 720W tower, 8x C13, sine wave, USB A+C — 1200 VA \/ 720 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-br-1300va\"\u003eBR1300MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1300VA \/ 780W tower, 8x C13 — 1300 VA \/ 780 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1500va-865w-tower-230v-10x-iec-c13-outlets-avr-lcd-br1500gi\"\u003eBR1500GI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1500VA \/ 865W tower, 10x C13, external pack capable — 1500 VA \/ 865 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-1600va-960w-tower-230v-br1600mi\"\u003eBR1600MI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13 — 1600 VA \/ 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro, 1600VA \/ 960W tower, 8x C13, sine wave, USB A+C — 1600 VA \/ 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-back-ups-pro-external-battery-pack-for-1500va-back-ups-pro-models-br24bpg\"\u003eBR24BPG\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBack-UPS Pro external battery pack, 24 V \/ 372 VAh (for BR1500GI) — Battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMatching replacement battery cartridge\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003eAPCRBC161\u003c\/td\u003e\n\u003ctd\u003eReplacement battery cartridge for the BR1200SI — \u003ca href=\"\/products\/apc-replacement-battery-cartridge-161-apcrbc161\"\u003eAPCRBC161\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003cp\u003eRail kits and network management cards do not apply to this range: every Back-UPS Pro BR model is a tower with no SmartSlot. For rack-mount or network-managed power protection, ask us about the APC Smart-UPS SMT, SMC and SMX ranges.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eLinks open on Schneider Electric's own site. Each one was checked before publication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/BR1200SI\/apc-backups-pro-1200va-720w-tower-230v-8x-iec-c13-outlets-sine-wave-avr-usb-type-a-+-c-ports-lcd-user-replaceable-battery\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page for the APC BR1200SI\u003c\/a\u003e — official product name, characteristics and the full document list (United Kingdom site)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/SPD_AHUG-B6CBPT_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Back-UPS Pro BR1200SI \/ BR1600SI User Manual (Schneider document library)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSchneider's direct datasheet PDF links sit behind a path that blocks automated retrieval, so we link the product page and the document library entry instead — every link above resolves and carries the current document. If you need the datasheet or manual emailed to you as a file for a tender submission, ask us and we will send it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC BR1200SI\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eWhat is the difference between the 1200 VA and the 720 W rating?\u003c\/h4\u003e\n\u003cp\u003e1200 VA is apparent power and 720 W is real power. Your equipment consumes real power, so the 720 W figure is the one that limits what you can connect. Add up the wattage on the nameplates of everything you intend to back up and keep the total comfortably below 720 W.\u003c\/p\u003e\n\u003ch4\u003eHow long will the BR1200SI run my equipment?\u003c\/h4\u003e\n\u003cp\u003eIt depends entirely on load, and Schneider publishes no runtime table for this model — which is why you will not find minutes quoted on this page. A lightly loaded unit runs for many minutes; one near 720 W runs for a few. Send SourceIT your load in watts and we will calculate it against the 204 VAh battery rating rather than guess.\u003c\/p\u003e\n\u003ch4\u003eWhat does the \"SI\" in BR1200SI mean?\u003c\/h4\u003e\n\u003cp\u003eIt identifies the build variant. SI is the newer 230 V build with true sine wave output and two USB charging ports (Type A and Type C) — a genuinely different unit from the same-VA \"MI\" model, not just a cosmetic variation. These suffixes are not interchangeable — outlet counts, waveform and battery cartridge all change with them, so order by the exact part number.\u003c\/p\u003e\n\u003ch4\u003eIs the output a pure sine wave, and will it drive an active-PFC power supply?\u003c\/h4\u003e\n\u003cp\u003eYes — Schneider's official product name for the BR1200SI states sine wave output, so it suits active-PFC ATX power supplies, NAS units and other equipment that objects to a stepped waveform.\u003c\/p\u003e\n\u003ch4\u003eWhich replacement battery does it take, and can I fit it myself?\u003c\/h4\u003e\n\u003cp\u003eThe APC replacement battery cartridge for the BR1200SI is \u003cstrong\u003eAPCRBC161\u003c\/strong\u003e, stocked here: \u003ca href=\"\/products\/apc-replacement-battery-cartridge-161-apcrbc161\"\u003eAPCRBC161\u003c\/a\u003e. It is user-replaceable — no tools beyond a screwdriver and no service call. APC does not describe this model's battery as swappable while running, so shut the unit down for the swap. Expect three to five years of service in an air-conditioned office, and less in a hot, humid comms cupboard.\u003c\/p\u003e\n\u003ch4\u003eCan I rack mount it or add a network management card?\u003c\/h4\u003e\n\u003cp\u003eNo on both counts. The BR1200SI is a tower unit with no rack ears or rail kit option, and the Back-UPS Pro BR range has no SmartSlot, so an AP9640 or AP9641 card cannot be fitted. If you need a 19-inch rack UPS or SNMP monitoring, ask SourceIT about the APC Smart-UPS SMT, SMC and SMX ranges.\u003c\/p\u003e\n\u003ch4\u003eHow does the BR1200SI compare with the BR1600SI?\u003c\/h4\u003e\n\u003cp\u003eThe \u003ca href=\"\/products\/apc-br1600si-back-ups-pro-1600va-960w-tower-230v-8x-iec-c13-outlets\"\u003eBR1600SI\u003c\/a\u003e is the same sine wave, USB-equipped build at 1600 VA \/ 960 W instead of 1200 VA \/ 720 W. Both are stocked by SourceIT in Singapore — tell us the load and the budget and we will tell you which one is the right buy.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty and a GST invoice?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC BR1200SI sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the BR1200SI with a 2-year manufacturer warranty. Note that Schneider states three years inside the European Community and two years elsewhere — Singapore takes the two-year term, and any listing quoting three years for this market has copied the European figure.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003ch3\u003eProduct Video\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/dZ-hRA5gJ48\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43075251601572,"sku":"BR1200SI","price":725.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/products\/apc-back-ups-pro-1200va720w-tower-230v-br1200si-817912.jpg?v=1672995000"},{"product_id":"apc-netshelter-metered-rack-pdu-ap8858","title":"APC NetShelter Metered Rack PDU","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Metered Rack PDU, 0U, 1 Phase, 3.7kW 230V 16A, (18) C13 \u0026amp; (2) C19, C20 Inlet (AP8858) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTwenty Outlets and Built-In Metering in a Half-Height 0U Strip\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Metered Rack PDU AP8858 puts eighteen IEC C13 and two IEC C19 outlets on a 902 mm vertical strip - roughly half the length of a full-height PDU - and takes no rack units at all. At 2.93 kg it is light enough to mount single-handed, which matters when you are working in a live cabinet.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e3.7 kW at 230 V Through an Ordinary C20 Inlet\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUnlike the 32 A models in this range, the AP8858 is fed through an IEC C20 inlet rather than a commando cord, so it connects to a standard 16 A supply from a UPS or upstream PDU without any electrical work. It carries 3.7 kW at 230 V or 3.3 kW at 208 V, and accepts an unusually wide 100-240 V input range.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMetering and Alarm Thresholds Built In\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AP8858 measures real power, current and voltage at device, phase and breaker-bank level to ±3%, with user-defined alarm thresholds on the bank currents so you find out about an approaching overload before a breaker trips. Web, SNMP and Telnet access are standard, with EcoStruxure IT reporting and a one-year Secure NMC subscription included.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Monitoring for a Singapore Cabinet\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA sensor port takes the AP9335T temperature probe or the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH temperature and humidity sensor\u003c\/a\u003e, so the PDU reports rack inlet conditions as well as load. In a local server room or comms cabinet - where a stalled aircon unit and high ambient humidity are both realistic failure paths - having that telemetry come from inside the rack is worth the small extra spend.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP8858 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Metered Rack PDU, 0U, 1PH, 3.3 kW 208 V 16 A or 3.7 kW 230 V 16 A, x18 C13 and x2 C19 outlets, C20 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP8858\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMetered Rack Power Distribution Unit (PDU), 2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eZero U (0U), vertical side mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C20 inlet - no cord is attached to this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e200 V, 208 V, 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceptable Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e100-240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e20 A maximum, regulatory derated to 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacity\u003c\/td\u003e\n\u003ctd\u003e3.7 kW at 230 V; 3.3 kW at 208 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eEighteen (18) IEC 60320 C13 and two (2) IEC 60320 C19 - 20 outlets total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003ctd\u003eUltra low-profile circuit breakers with user-defined alarm thresholds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMetering, Switching \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eDevice, phase and breaker-bank level metering of active real power, current and voltage. Not metered per outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3% (amps, volts, kW, kWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd\u003eNone - this is a Metered model, not a Switched one\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eBuilt in as standard - no separate card required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Interfaces\u003c\/td\u003e\n\u003ctd\u003eSecure Web, SNMP, Telnet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Platform\u003c\/td\u003e\n\u003ctd\u003eEcoStruxure IT (formerly InfraStruxure). A one-year Secure Network Management Card subscription is included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Configuration\u003c\/td\u003e\n\u003ctd\u003eSerial configuration cable supplied in the box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Sensors\u003c\/td\u003e\n\u003ctd\u003eAP9335T (temperature) or AP9335TH (temperature and humidity), sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided - no surge suppression is specified for this product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e902 x 56 x 44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e2.93 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e4.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Elevation\u003c\/td\u003e\n\u003ctd\u003e0 to 3,048 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 60950-1, CSA C22.2 No. 60950, IEC 60950, METI Denan, VDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e0731304277026\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Load Planning\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Eighteen IEC C13 outlets for C14-corded servers, switches and\nappliances, plus two IEC C19 outlets for 16 A C20-corded devices such as a blade chassis or a storage shelf.\nTwenty outlets covers a normally populated rack; if you need forty-two, that is the 32 A\n\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLoad planning.\u003c\/strong\u003e 16 A after regulatory derating (20 A maximum), giving 3.7 kW at\n230 V or 3.3 kW at 208 V. Twenty outlets sharing 16 A means the sockets are there for reach,\nnot so each can draw its maximum. The metering - device, phase and bank level to ±3% - lets you watch the\nheadroom, and user-defined alarm thresholds warn you before a breaker trips.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e A 0U vertical strip 902 mm long, 56 mm wide and 44 mm deep, weighing\n2.93 kg. At roughly half the length of a full-height strip it suits shorter enclosures and half-populated\nracks, and it consumes no rack units. For reference, the \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e is\n1,791 mm and the Basic \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552\u003c\/a\u003e is 1,619 mm.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeeding it - note the inlet.\u003c\/strong\u003e This model has an IEC C20 \u003cem\u003einlet\u003c\/em\u003e and no attached cord,\nwhich is the single biggest practical difference from the AP8853. You supply a 16 A C19-to-C20 cord from a\nUPS or upstream PDU. No commando socket and no electrical work required, which makes the AP8858 far easier to\ndeploy in an ordinary Singapore SME server room. Schneider does not state whether a cord is supplied in the box,\nso assume you need to provide one and ask us to include it in your quote.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eManagement and sensors.\u003c\/strong\u003e Secure Web, SNMP and Telnet access built in, EcoStruxure IT reporting,\na one-year Secure NMC subscription, and a serial configuration cable in the box. The environmental sensor port\ntakes the AP9335T or the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH temperature and humidity sensor\u003c\/a\u003e, sold\nseparately.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat it does not do.\u003c\/strong\u003e No outlet switching - for remote power-cycling you want a Switched model\nsuch as the \u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e. No per-outlet metering. And no surge protection - that\nis a UPS function, not a PDU one.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Metered and Switched Rack PDU Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC NetShelter Metered Rack PDU (AP8858)\u003c\/li\u003e\n\u003cli\u003eRack mounting brackets\u003c\/li\u003e\n\u003cli\u003eSerial configuration cable\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003cli\u003eSafety guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis model has a C20 inlet rather than an attached cord, and Schneider does not state whether an input cord is supplied. Assume you need a 16 A C19-to-C20 cord and ask us to quote one with the PDU.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMetered \u0026amp; Switched Rack PDU Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-switched-rack-pdu-ap7920b\"\u003eAP7920B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 10 A, 2.3 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C14 inlet, 2.4 m cord supplied\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-switched-1u-16a-208-230v-8c13\"\u003eAP7921B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitched\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3.7 kW\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, 2.4 m cord supplied\u003c\/td\u003e\n\u003ctd\u003e(8) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP8858 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMetered\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 16 A, 3.7 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC C20 inlet, no cord supplied\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(18) C13, (2) C19\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-metered-2u-32a-230v-12-c13-4-c19\"\u003eAP7822B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(12) C13, (4) C19\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered\u003c\/td\u003e\n\u003ctd\u003e230 V, 32 A, 7.4 kW\u003c\/td\u003e\n\u003ctd\u003eCaptive IEC 60309 32 A cord\u003c\/td\u003e\n\u003ctd\u003e(36) C13, (6) C19\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Sensor (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335TH\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAPC Temperature \u0026amp; Humidity Sensor\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eAPC also makes a temperature-only probe, the AP9335T, which this PDU's sensor port accepts. We do not hold it as a stock line - ask us and we will quote it.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP8858. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/download\/document\/990-3434_EN\" target=\"_blank\" rel=\"noopener\"\u003eAPC Metered Rack PDU AP8858 - Overview and Specifications (990-3434_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/AP8858\/apc-netshelter-metered-rack-pdu-0u-1ph-3-3kw-208v-16a-or-3-7kw-230v-16a-x18-c13-and-x2-c19-outlets-c20-inlet\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric AP8858 product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/id\/en\/faqs\/FAQ000277528\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric Rack PDU warranty policy (FAQ000277528)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP8858\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eTwo listings in our store share the title \"APC NetShelter Metered Rack PDU\" - which one is this?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis is AP8858, the 16 A model: 3.7 kW at 230 V, twenty outlets (18 C13 and 2 C19), a 902 mm strip with a C20 inlet and no attached cord, 2.93 kg. The other listing is \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e, the 32 A model: 7.4 kW, forty-two outlets, a 1,791 mm strip with a captive IEC 60309 commando cord, 6.93 kg. Check the part number before you order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes an input cord come with it?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSchneider does not state one. The AP8858 has a C20 inlet rather than a captive cord, and no cord length appears in any published document for this part - so plan on providing a 16 A C19-to-C20 cord, and ask us to quote one alongside the PDU. We would rather tell you that than guess.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs it metered per outlet?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Metering is at device, phase and breaker-bank level - active real power, current and voltage, to ±3%. Per-outlet measurement is a different product class. Bank-level metering with alarm thresholds is what you need to balance load and get warned before a breaker trips.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDo I need a network management card?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. Secure Web, SNMP and Telnet access are built in, with EcoStruxure IT reporting and a one-year Secure Network Management Card subscription included. The AP9640 and AP9641 cards we sell are Smart-UPS accessories and are not used with this PDU.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan I add environmental monitoring?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes - the sensor port takes the AP9335T temperature probe or the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH temperature and humidity sensor\u003c\/a\u003e, sold separately. Worth adding in a Singapore cabinet, where both rack inlet temperature and humidity are real operational concerns.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it have surge protection?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. No Schneider document for the AP8858 contains a surge section, joule rating or clamping figure. Surge suppression is a UPS function, not a PDU one.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does it compare with the Basic AP7552?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552\u003c\/a\u003e is a Basic 0U strip - twenty-four outlets, 16 A, 3.68 kW, 1,619 mm long, and no metering, display or network port at all. The AP8858 has four fewer outlets and a shorter body but adds metering, an alarm-capable breaker, a network port and a sensor port. If you want to see and be warned about your rack load, the AP8858 is the one; if measurement already happens upstream, the AP7552 is cheaper.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Metered Rack PDU AP8858 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the AP8858 with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43075262283940,"sku":"AP8858","price":725.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_de2d6ce5-9ad3-4c0a-a275-b33e059dcd0a.jpg?v=1789720755"},{"product_id":"apc-rack-pdu-basic-zero-u-32a-230v-ap7553","title":"APC Rack PDU, Basic, Zero U, 32A, 230V","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC NetShelter Basic Rack PDU, Zero U, 32A, 230V, (20) C13 \u0026amp; (4) C19, IEC 309 Inlet (AP7553) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e7.4 kW of Distribution, Zero Rack Units Consumed\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe APC NetShelter Basic Rack PDU AP7553 delivers up to 7,400 VA at 230 V and 32 A through twenty-four outlets, and takes no usable rack space at all. Mounted vertically in the rear channel of the enclosure, it is the high-capacity way to power a fully loaded rack without giving up a single U to the PDU itself.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e32 A Commando Input for Serious Loads\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA 3.05 m captive IEC 60309 32 A 2P+E cord feeds the strip. That is a fixed electrical connection rather than a wall plug, so the rack needs a 32 A commando outlet - the trade-off for roughly double the capacity of the 16 A \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552\u003c\/a\u003e on an otherwise identical strip.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTwenty C13 and Four C19 Outlets\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTwenty IEC C13 outlets handle servers, switches and appliances; four IEC C19 outlets take the 16 A C20-corded equipment - blade chassis, storage shelves, large core switches - that a C13-only strip cannot serve. Twenty-four outlets is enough to cable an entire rack from one strip.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eA 1.6 Metre Full-Height Strip\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe AP7553 measures 1,619 mm long, 56 mm wide and 44 mm deep and weighs 5.57 kg, sized to run the height of a standard 42U enclosure. Rack brackets and a toolless mounting kit are supplied. Third-party listings sometimes quote a much shorter length for this part, so check your enclosure against the 1,619 mm figure before ordering.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP7553 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eAPC NetShelter Basic Rack PDU, Zero U, 32 A, 230 V, 20 C13 and 4 C19 outlet, IEC 309 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP7553\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBasic Rack Power Distribution Unit (PDU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eZero U (0U), vertical side mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty\u003c\/td\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 32 A 2P+E captive cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e3.05 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e200 V, 208 V, 230 V (230 VAC nominal, ±10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Rating\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacity\u003c\/td\u003e\n\u003ctd\u003e7,400 VA (7.4 kW at 230 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput \u0026amp; Receptacles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003eTwenty (20) IEC 60320 C13 and four (4) IEC 60320 C19 - 24 outlets total\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMetering, Switching \u0026amp; Management\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eNone - this is a Basic PDU with no meter and no local display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eNone - there is no network port on this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Switching\u003c\/td\u003e\n\u003ctd\u003eNone - outlets are always live when the PDU is powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided - no surge suppression is specified for this product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e1,619 x 56 x 44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e5.57 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e6.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, VDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS \/ REACh\u003c\/td\u003e\n\u003ctd\u003eEU RoHS compliant; REACh declaration available; lead-free; Schneider Green Premium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Load Planning\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you can plug into it.\u003c\/strong\u003e Twenty IEC C13 outlets for C14-corded equipment - servers,\nswitches, routers, appliances - plus four IEC C19 outlets rated to 16 A for C20-corded devices such as blade\nchassis, storage shelves and large core switches. The outlet layout is identical to the 16 A\n\u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552\u003c\/a\u003e; only the input and the capacity differ.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLoad planning.\u003c\/strong\u003e 32 A and 7,400 VA (7.4 kW) at 230 V. That is genuinely a\nfull-rack capacity, but there is no meter on this model to tell you how close you are running - so either\nmeasure upstream at the UPS or row PDU, or choose a metered model. Allow headroom for the inrush when an entire\nrack restarts together after an outage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRack fit.\u003c\/strong\u003e 0U vertical, 1,619 mm long, 56 mm wide, 44 mm deep, 5.57 kg.\nIt mounts in the rear vertical channel and costs you no rack units. Check that your enclosure is tall enough and\nhas the channel depth to take a 1.6 m strip - in a short or wall-mount cabinet no 0U strip will fit at all,\nand the 1U \u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559\u003c\/a\u003e (16 A, ten C13 plus two C19) is the nearest practical\nalternative, at roughly half the capacity.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeeding it - read this before ordering.\u003c\/strong\u003e The input is a captive 3.05 m IEC 60309\n32 A 2P+E commando cord. There is no plug-in-the-wall option: the rack needs a 32 A commando socket on\na dedicated circuit, which usually means an electrician and a lead time. If that circuit does not already exist,\nthe 16 A \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552\u003c\/a\u003e on a C20 inlet is far easier to deploy.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eManagement and monitoring.\u003c\/strong\u003e None, by design. No meter, no display, no LEDs, no network port -\nSchneider publishes none of those fields for the AP7553. Descriptions of this part elsewhere sometimes mention\nLED status indicators or surge protection; neither is supported by any Schneider document for this model.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; Basic Rack PDU Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x APC NetShelter Basic Rack PDU (AP7553) with 3.05 m IEC 60309 32 A input cord\u003c\/li\u003e\n\u003cli\u003eRack mounting brackets\u003c\/li\u003e\n\u003cli\u003eToolless mounting kit\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eBasic Rack PDU Range — Ordering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-12c13\"\u003eAP9565\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3,680 VA\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, 2.5 m cord supplied\u003c\/td\u003e\n\u003ctd\u003e(12) C13\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-1u-16a-208-230v-ap9559\"\u003eAP9559\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3,680 VA\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, 2.5 m cord supplied\u003c\/td\u003e\n\u003ctd\u003e(10) C13, (2) C19\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 16 A, 3,680 VA\u003c\/td\u003e\n\u003ctd\u003eIEC C20 inlet, cord to be confirmed\u003c\/td\u003e\n\u003ctd\u003e(20) C13, (4) C19\u003c\/td\u003e\n\u003ctd\u003e0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAP7553 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V, 32 A, 7,400 VA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCaptive IEC 60309 32 A cord\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(20) C13, (4) C19\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0U\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eLocking Output Cords (Sold Separately)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThese are the cords that run from this unit's C13 outlets to your equipment's C14 inlets. The locking design stops a cord being nudged out of its outlet while you work in the rack - a common and entirely avoidable cause of an unplanned reboot. Note that this is an \u003cem\u003eoutput\u003c\/em\u003e cord kit, not this unit's supply cord - if you also need an input cord, tell us and we will quote the right type for this model.\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP8704S-WW\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-power-cord-kit\"\u003eAPC Power Cord Kit (6 ea), Locking, C13 to C14, 1.2 m\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP7553. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/in\/en\/download\/document\/990-1895_EN\/\" target=\"_blank\" rel=\"noopener\"\u003eAPC Rack PDU AP7553 - Specification Guide (990-1895_EN)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/sg\/en\/product\/AP7553\/rack-pdu-basic-zero-u-32a-230v-20c13-4c19\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric AP7553 product page (Singapore)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/id\/en\/faqs\/FAQ000277528\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric Rack PDU warranty policy (FAQ000277528)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP7553\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat supply does the AP7553 need?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA 32 A IEC 60309 2P+E commando outlet on a dedicated circuit. The 3.05 m input cord is captive, so there is nothing to buy, but the socket itself is a fixed electrical installation. If your rack does not already have one, factor in an electrician - or choose the 16 A \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552\u003c\/a\u003e, which uses a straightforward C20 inlet.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow long is the strip?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1,619 mm - about 1.6 metres, sized for a full-height 42U enclosure, 56 mm wide and 44 mm deep. Shorter figures circulate for this part in third-party data; measure your vertical channel against 1,619 mm before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it have surge protection or status LEDs?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNeither. No Schneider document for the AP7553 contains a surge specification, a joule rating, or any mention of LEDs or a display. Both claims circulate in third-party descriptions of this part and neither is supported. Surge and sag protection belongs upstream at a UPS.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan I meter the load on this PDU?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNot on the PDU itself - it is a Basic model with no meter and no network port. You can meter upstream at the UPS or row PDU, or choose a metered rack PDU. In this catalogue the \u003ca href=\"\/products\/apc-netshelter-metered-rack-pdu-ap8853\"\u003eAP8853\u003c\/a\u003e is the closest metered equivalent: also 0U, also 32 A and 7.4 kW on an IEC 60309 cord, with unit and bank-level metering, an LCD and a built-in network port.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow does it differ from the AP7552?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOnly the input and the capacity. Same 1,619 mm strip, same twenty C13 and four C19 outlets. The AP7553 is 32 A \/ 7.4 kW on an IEC 60309 commando cord; the \u003ca href=\"\/products\/apc-rack-pdu-basic-zero-u-16a-230v-ap7552\"\u003eAP7552\u003c\/a\u003e is 16 A \/ 3.68 kW on a C20 inlet. Choose on the circuit you have available and the total draw you need.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs 32 A overkill for my rack?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOften, yes - a typical Singapore SME comms cabinet of switches and a couple of servers rarely exceeds 16 A. The 32 A models earn their place in dense compute or storage racks, or where you want one strip to carry a rack that will grow. If you are unsure, send us your equipment list and we will work out the actual draw.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDoes it come with local Singapore warranty and a GST invoice?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. Every APC NetShelter Basic Rack PDU AP7553 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the AP7553 with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43075270443172,"sku":"AP7553","price":555.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_ba068f19-56ae-4b86-84a9-42b8b1d98b57.jpg?v=1789720781"},{"product_id":"apc-dry-contact-i-o-smartslot-card-ap9613","title":"APC Dry Contact I\/O SmartSlot Card","description":"\u003cdiv\u003e\n\u003cstyle\u003e\n.pd-acc { border: 1px solid #e2e2e2; border-radius: 8px; margin: 10px 0; overflow: hidden; }\n.pd-acc summary { cursor: pointer; padding: 14px 16px; font-weight: 700; font-size: 1.05em; list-style: none; display: flex; justify-content: space-between; align-items: center; background: #f7f7f7; }\n.pd-acc[open] \u003e summary { border-bottom: 1px solid #e2e2e2; }\n.pd-acc summary::-webkit-details-marker { display: none; }\n.pd-acc summary::after { content: \"+\"; font-size: 1.4em; font-weight: 400; line-height: 1; margin-left: 12px; }\n.pd-acc[open] \u003e summary::after { content: \"\\2212\"; }\n.pd-acc .pd-acc-body { padding: 8px 16px 14px; }\n.pd-spec, .pd-spec tr, .pd-spec td { border: none !important; background: transparent !important; }\n.pd-spec { width: 100%; border-collapse: collapse !important; margin: 6px 0 18px; }\n.pd-spec td { padding: 7px 10px 7px 0 !important; border-bottom: 1px solid #ececec !important; vertical-align: top; font-size: 0.95em; text-align: left; }\n.pd-spec td:first-child { width: 38%; font-weight: 600; color: #333; }\n.pd-spec tr:last-child td { border-bottom: none !important; }\n\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003eAPC Dry Contact I\/O SmartSlot Card, 4 Input Contacts \u0026amp; 6 Output Relays, 2 Universal I\/O Ports (AP9613) - 2 Years Local Warranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eSix Output Relays and Four Input Contacts in One APC SmartSlot Card\u003c\/h3\u003e\n\u003cp\u003eThe APC Dry Contact I\/O SmartSlot Card (AP9613) turns a spare SmartSlot bay in your Smart-UPS into a hard-wired signalling interface. Schneider Electric's installation manual for the card specifies four opto-isolated input contacts and six output relays, and both counts can be lifted to eight by adding the optional AP9810 dry contact I\/O accessory. That gives you volt-free contacts to drive an alarm panel, a beacon, a generator start signal or a building management system directly from UPS events, with no software layer in between.\u003c\/p\u003e\n\u003cp\u003eEach output relay is rated 0 to 30 VAC or VDC at a maximum of 3 A, with 16 A total across all six relays. The card is configured with DIP switches and a USB-connected configuration utility, so commissioning is a bench job rather than a network project.\u003c\/p\u003e\n\u003ch3\u003eDry Contact Signalling for Building Management and Generator Control\u003c\/h3\u003e\n\u003cp\u003ePlenty of Singapore server rooms, comms cabinets and industrial cabinets still run on volt-free contacts rather than SNMP. Fire panels, BMS head-ends, PLC inputs, generator auto-start controllers and older alarm annunciators all expect a simple open or closed circuit. The AP9613 gives your APC UPS that language: map UPS conditions onto relay outputs, and feed external conditions - a door switch, a leak detector, a plant alarm - back in through the input contacts.\u003c\/p\u003e\n\u003cp\u003eBecause the interface is electrical rather than networked, it keeps working when the network does not. That matters during exactly the events you bought a UPS for.\u003c\/p\u003e\n\u003ch3\u003eTwo Universal I\/O Ports for Temperature and Humidity Sensing\u003c\/h3\u003e\n\u003cp\u003eThe AP9613 carries two universal I\/O ports (ports 1 and 2). Schneider's manual confirms these accept the AP9335T temperature sensor, the AP9335TH temperature and humidity sensor, and the AP9810 dry contact accessory. In Singapore's climate that is a practical addition: a comms cabinet that loses cooling over a long weekend heats and humidifies quickly, and a sensor on the UPS itself will tell you before the hardware does.\u003c\/p\u003e\n\u003cp\u003eAdd the AP9335TH and the same card that drives your alarm contacts also watches the rack's temperature and relative humidity.\u003c\/p\u003e\n\u003ch3\u003eFits APC UPS Units With a Free SmartSlot\u003c\/h3\u003e\n\u003cp\u003ePer the AP9613 installation manual the card suits most APC by Schneider Electric UPS devices with an output rated at or below 160 kVA and an available SmartSlot bay - which typically covers the Smart-UPS, Smart-UPS X and Smart-UPS On-Line ranges SourceIT stocks, though the pairing should be confirmed per model. Most Smart-UPS models have a single SmartSlot, so plan whether that bay carries a network management card or this dry contact card before you order; SourceIT can confirm the slot count for your exact model.\u003c\/p\u003e\n\u003cp\u003eSupplied and invoiced locally in Singapore with GST, from stock.\u003c\/p\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eAPC AP9613 Datasheet — Technical Specifications\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (SKU)\u003c\/td\u003e\n\u003ctd\u003eAP9613\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSchneider Electric Product Name\u003c\/td\u003e\n\u003ctd\u003eDry Contact I\/O Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAPC Management Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eAPC SmartSlot plug-in card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDry contact input and output signalling interface for APC UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-Year Manufacturer Warranty (APC by Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Warranty (Singapore)\u003c\/td\u003e\n\u003ctd\u003eYes - supplied and supported locally by SourceIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFunction \u0026amp; Connectivity\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Contacts\u003c\/td\u003e\n\u003ctd\u003e4 opto-isolated input contacts (expandable to 8 with the optional AP9810)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Relays\u003c\/td\u003e\n\u003ctd\u003e6 output relays (expandable to 8 with the optional AP9810)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Relay Rating\u003c\/td\u003e\n\u003ctd\u003e0 to 30 VAC or VDC, 3 A maximum per relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Relay Current\u003c\/td\u003e\n\u003ctd\u003e16 A across all relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniversal I\/O Ports\u003c\/td\u003e\n\u003ctd\u003e2 (ports 1 and 2) - accept AP9335T, AP9335TH and AP9810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eDIP switches plus a USB-connected configuration utility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPS Compatibility\u003c\/td\u003e\n\u003ctd\u003eMost APC UPS devices rated 160 kVA or below with an available SmartSlot - confirm your exact model with SourceIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e38 x 121 x 108 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.21 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0 to 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-15 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eEN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-6, FCC Part 15 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eCompatibility \u0026amp; Fit\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhich APC UPS units take the AP9613.\u003c\/strong\u003e The AP9613 installs in an APC SmartSlot bay. Schneider's installation manual for the card states it suits most APC by Schneider Electric UPS devices with an output rated at or below 160 kVA that have an available SmartSlot. In the SourceIT catalogue that will typically include the Smart-UPS SmartConnect range, the Smart-UPS X range and the Smart-UPS On-Line SRT range - ask us to confirm your model. Most single-phase Smart-UPS models provide one SmartSlot only, so the AP9613 and a network management card compete for the same bay - decide which function the slot serves before ordering, or ask us to check your specific model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat connects to the card.\u003c\/strong\u003e Two universal I\/O ports accept the \u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAPC Temperature \u0026amp; Humidity Sensor (AP9335TH)\u003c\/a\u003e, the AP9335T temperature-only sensor, and the AP9810 dry contact I\/O accessory. Adding the AP9810 expands the card to eight input contacts and eight output relays, per the AP9613 manual. AP9335T and AP9810 are not stocked lines - ask SourceIT to source them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat the relay outputs can drive.\u003c\/strong\u003e Each relay switches 0 to 30 VAC or VDC at up to 3 A, with a 16 A total budget across all relays. That suits signalling duties - alarm panel inputs, BMS digital inputs, beacons, generator start contacts, PLC inputs. It is a signalling interface, not a power switch: do not use the relays to carry load current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork management is a separate product.\u003c\/strong\u003e The AP9613 does not put the UPS on the network. If you need SNMP, HTTPS, EcoStruxure IT or PowerChute Network Shutdown, that is the \u003ca href=\"\/products\/apc-ups-network-management-card-3-ap9640\"\u003eNetwork Management Card 3 (AP9640)\u003c\/a\u003e, or the \u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641\u003c\/a\u003e if you also want sensor ports. The AP9641 combines network management with two universal I\/O ports, which will accept an AP9810 dry contact accessory if you also need contacts from that slot.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003ePackage Contents \u0026amp; APC UPS Management Ordering Information\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eIn the box.\u003c\/strong\u003e Schneider Electric does not publish a package contents list for the AP9613 that we can verify, so we do not reproduce one here. SourceIT will confirm exactly what ships with your unit before you order.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPC UPS management and monitoring options in the SourceIT catalogue\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDry contact input \/ output signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAP9613 (this listing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork management - SNMP, HTTPS, SSH, Modbus, BACnet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-ap9640\"\u003eAP9640\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork management plus 2 universal I\/O sensor ports\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-ups-network-management-card-3-with-environmental-monitoring-ap9641\"\u003eAP9641\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature and humidity sensor (RJ45, 3.9 m lead)\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAP9335TH\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack-level environmental and access monitoring appliance\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/apc-netbotz-rack-mount-security-and-environmental-appliance-nbrk0250a\"\u003eNBRK0250A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSensors and accessories for the universal I\/O ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"pd-spec\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335TH\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/apc-temperature-humidity-sensor\"\u003eAPC AP9335TH temperature and humidity sensor\u003c\/a\u003e - stocked by SourceIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9335T\u003c\/td\u003e\n\u003ctd\u003eTemperature-only sensor - not stocked, available to order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP9810\u003c\/td\u003e\n\u003ctd\u003eDry contact I\/O accessory - expands the card to 8 input contacts and 8 output relays; not stocked, available to order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eDatasheet \u0026amp; Downloads\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003cp\u003eOfficial Schneider Electric documentation for the APC AP9613. Links open in a new tab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.se.com\/us\/en\/product\/AP9613\/dry-contact-management-options-dry-contact-i-o-card-monitor-external-ups-environmental-sensors-output-relays-and-input-contacts\/\" target=\"_blank\" rel=\"noopener\"\u003eSchneider Electric product page - AP9613 Dry Contact I\/O Card\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed a specific document, a compliance declaration or a written quotation? Contact SourceIT and we will supply it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"pd-acc\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 700;\"\u003eFrequently Asked Questions — APC AP9613\u003c\/summary\u003e\u003cdiv class=\"pd-acc-body\"\u003e\n\u003ch4\u003eHow many inputs and outputs does the AP9613 actually have?\u003c\/h4\u003e\n\u003cp\u003eFour opto-isolated input contacts and six output relays, per Schneider Electric's installation manual for the card. Adding the optional AP9810 dry contact I\/O accessory expands both to eight.\u003c\/p\u003e\n\u003ch4\u003eWhat can the output relays switch?\u003c\/h4\u003e\n\u003cp\u003eEach relay is rated 0 to 30 VAC or VDC at up to 3 A, with a 16 A total budget across all relays. That is a signalling rating, not a load-switching rating. Use it to drive alarm panel inputs, BMS digital inputs, beacons, PLC inputs or a generator start contact - not to carry equipment load.\u003c\/p\u003e\n\u003ch4\u003eWill the AP9613 fit my UPS?\u003c\/h4\u003e\n\u003cp\u003eIt needs an available APC SmartSlot bay. Schneider's manual gives the scope as most APC UPS devices rated 160 kVA or below with a free SmartSlot, which covers the Smart-UPS, Smart-UPS X and Smart-UPS On-Line SRT ranges we stock. The catch is slot count: most single-phase Smart-UPS models have exactly one SmartSlot, so a dry contact card and a network management card compete for it. Send us your UPS part number and we will confirm what your model provides.\u003c\/p\u003e\n\u003ch4\u003eDoes the AP9613 put my UPS on the network?\u003c\/h4\u003e\n\u003cp\u003eNo. It is an electrical signalling card, not a network card. For SNMP, HTTPS, SSH, Modbus, BACnet, EcoStruxure IT or PowerChute Network Shutdown you want the AP9640 Network Management Card 3, or the AP9641 if you also need sensor ports. The AP9641 is worth comparing here because it bundles network management with two universal I\/O ports, which will take an AP9810 dry contact accessory - in a single-SmartSlot UPS that combination often beats choosing between the two cards.\u003c\/p\u003e\n\u003ch4\u003eCan I connect a temperature sensor to it?\u003c\/h4\u003e\n\u003cp\u003eYes. The card has two universal I\/O ports that accept the AP9335TH temperature and humidity sensor or the AP9335T temperature-only sensor. The AP9335TH is a stocked SourceIT line with a 3.9 m RJ45 lead.\u003c\/p\u003e\n\u003ch4\u003eHow is the card configured?\u003c\/h4\u003e\n\u003cp\u003eThrough DIP switches on the card plus a configuration utility over USB. There is no web interface; the card's purpose is hard-wired signalling that keeps working independently of the network.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a Singapore warranty?\u003c\/h4\u003e\n\u003cp\u003eYes. Every APC AP9613 sold by SourceIT comes with local Singapore warranty and a GST invoice; APC backs the AP9613 with a 2-year manufacturer warranty.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"APC Schneider Electric","offers":[{"title":"Default Title","offer_id":43075273097380,"sku":"AP9613","price":465.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/0136\/0804\/files\/files_d160f39a-429e-4c85-bfe4-da1b0d7da7af.jpg?v=1789720805"}],"url":"https:\/\/sourceit.com.sg\/collections\/ups-power-protection.oembed?page=19","provider":"SourceIT ","version":"1.0","type":"link"}